855-835-03-2 AC Electrical Load Analysis.pdf
PDF 199 KB Posted
- Solicitation number
- RFP - 751 - 240000000319
- Issued by
- Ingham County, Lansing City, Michigan
About this file
This document is an AC Electrical Load Analysis for a research vessel being procured by the Michigan Department of Natural Resources. The document outlines the electrical load requirements for various systems and components on the vessel, including panels AC-1 through AC-5 which cover the engine room, pilot house, galley, inverter, and heaters respectively. The total electrical load is calculated to be approximately 88.61 kW or 385.27 Amps.
The related state and local contract opportunity is for the build-out of a new 66 ft Fisheries Research Vessel for the State of Michigan Department of Natural Resources. The bid due date has been extended to Thursday, February 29, 2024 at 3:00 p.m. Eastern Time. Bidders are requested to submit a proposed timeline if they cannot meet the one-year completion date, and the SEAKEEPER specification has been added as an addendum to the bid documents. The contract is open to qualified shipyards, and the Michigan DNR will evaluate bids based on qualifications, experience, price, and completion timeline.
View the file
Other files
Show 40 more
Latest 50 of 64 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OWNER:
REVISIONS:
No: By: Date:
0 JHP 19-Sep-23 1 JHP 22-Sep-23 2 JHP 19-Oct-23
PREPARED BY:
DRAWN BY:
JHP
DATE:
09/19/23
REV:
(813) 654-9800
Michigan Department of Natural Resources Charlevoix Fisheries Research Station
96 Grant St.
Charlevoix, MI 49720
16627 Fishhawk Blvd.
Suite 101
Lithia, FL 33547
RELEASE FOR DESIGN PACKAGE
REMOVED NMEA POWER SUPPLY
REMOVED RES 1, REVISED STOVE SIZE
855-835-03 1 OF 5
www.bmdinc.com
VESSEL:
RESEARCH VESSEL
DRAWING TITLE:
AC ELECTRICAL LOAD ANALYSIS
DWG #: SHEET:
LF LOAD LF LOAD LF LOAD LF LOAD LF LOAD LF LOAD
PANEL AC-1 ENGINE ROOM (120/240 VAC) 240 26.51 8.31 8.31 1.89 5.53 3.91 10.64
PANEL AC-2 PILOT HOUSE (120/240 VAC) 240 28.50 8.98 12.18 6.55 8.23 3.71 4.68
PANEL AC-3 GALLEY (120/240 VAC) 240 18.68 2.15 2.15 2.63 1.84 0.42 0.32
HYDRAULIC PUMP 240 20.00 14.91 0.20 2.98 0.20 2.98 0.00 0.00 0.90 13.42 0.00 0.00 0.00 0.00
TOTAL LOAD (kW) 88.61 kW
TOTAL LOAD (A) approx. 385.27 A
LF LOAD LF LOAD LF LOAD LF LOAD LF LOAD LF LOAD
1 AIR COMPRESSOR 240 4.00 2.98 - 0.20 0.60 0.20 0.60 0.10 0.30 0.10 0.30 0.00 0.00 1.00 2.98 2 FRESH WATER PUMP 240 0.50 0.37 - 0.50 0.19 0.50 0.19 0.50 0.19 0.50 0.19 0.00 0.00 0.00 0.00 5 WATER HEATER 240 4.50 - 0.10 0.45 0.10 0.45 0.10 0.45 0.10 0.45 0.00 0.00 0.00 0.00 6 BILGE PUMP 240 2.00 1.49 - 0.10 0.15 0.10 0.15 0.05 0.07 0.05 0.07 0.05 0.07 1.00 1.49 9 SEAKEEPER 240 3.70 - 0.65 2.41 0.65 2.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10 ENGINE ROOM SUPPLY FAN 240 5.00 3.73 - 1.00 3.73 1.00 3.73 0.00 0.00 1.00 3.73 0.00 0.00 1.00 3.73 13 ENGINE START BATTERY CHARGER 120 1.50 L1 0.10 0.15 0.10 0.15 0.10 0.15 0.10 0.15 0.40 0.60 1.00 1.50 14 GEN START BATTERY CHARGER 120 0.60 L1 0.10 0.06 0.10 0.06 0.10 0.06 0.10 0.06 0.40 0.24 1.00 0.60 15 PORT ENGINE BLOCK HEATER 120 1.50 L2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.00 1.50 0.00 0.00 16 STBD ENGINE BLOCK HEATER 120 1.50 L2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.00 1.50 0.00 0.00 17 ENGINE ROOM LIGHTS (4 x 40W) 120 0.16 L1 0.10 0.02 0.10 0.02 1.00 0.16 0.10 0.02 0.00 0.00 1.00 0.16 18 ENGINE ROOM OUTLETS (x3) 120 1.80 L1 0.05 0.09 0.05 0.09 0.05 0.09 0.05 0.09 0.00 0.00 0.00 0.00 19 STORES OUTLETS (x2) 120 1.80 L2 0.05 0.09 0.05 0.09 0.05 0.09 0.05 0.09 0.00 0.00 0.00 0.00 20 STORES LIGHTS (4 x 40W) 120 0.16 L2 0.10 0.02 0.10 0.02 1.00 0.16 0.10 0.02 0.00 0.00 1.00 0.16 21 STORES CHEST FREEZER 120 0.50 L1 0.30 0.15 0.30 0.15 0.30 0.15 0.30 0.15 0.00 0.00 0.00 0.00 22 STORES SUPPLY FAN 120 0.02 L1 1.00 0.02 1.00 0.02 1.00 0.02 1.00 0.02 0.00 0.00 1.00 0.02 23 AFT DECK LIGHTS (2 x 100W) 120 0.20 L2 1.00 0.20 1.00 0.20 0.00 0.00 1.00 0.20 0.00 0.00 0.00 0.00
24 SPARE 120 L2
TOTAL (kW) 26.51 kW 8.31 kW 8.31 kW 1.89 kW 5.53 kW 3.91 kW 10.64 kW TOTAL (A) approx. 115.28 A 36.12 A 36.12 A 8.21 A 24.04 A 17.02 A 46.27 A
8.0511.0722.42
PANEL AC-1 ENGINE ROOM (120/240 VAC)
29.02
HYDR. OPS,
ENGINES IDLEL1/L2
L1/L2
HP
25.62
DESCRIPTION
V
68.01
AC ELECTRICAL LOAD ANALYSIS
REMARKSWINTER LAYUPSHORE POWER
SPRING/FALL
UNDERWAY
SUMMER
UNDERWAYHP KWV
DESCRIPTIONCI
RC
U
IT HYDR. OPS,
ENGINES IDLE
CI
RC
U
IT
EMERGENCY
15.64
EMERGENCYKW
SUMMER
UNDERWAY
MAIN SWITCHBOARD
SPRING/FALL
UNDERWAY SHORE POWER WINTER LAYUP REMARKS
97.49 111.40 48.14 126.19 34.99
BOKSA MARINE DESIGN, INC SHEET 2 855-835-03
1 A/C SPLIT OUTDOOR UNIT 240 5.20 - 0.50 2.60 0.50 2.60 0.50 2.60 0.50 2.60 0.00 0.00 0.00 0.00 2 A/C AHU OUTDOOR UNIT 240 3.80 - 0.50 1.90 0.50 1.90 0.50 1.90 0.50 1.90 0.00 0.00 0.00 0.00
5 SPARE
6 ICE MACHINE 240 2.50 - 0.60 1.50 0.40 1.00 0.20 0.50 0.20 0.50 0.00 0.00 0.00 0.00 9 SEARCHLIGHT 120 0.50 L1 0.10 0.05 0.10 0.05 0.00 0.00 0.10 0.05 0.00 0.00 1.00 0.50 10 DEFROST 240 2.20 - 0.00 0.00 1.00 2.20 0.00 0.00 0.50 1.10 0.50 1.10 1.00 2.20 11 HOUSE BATTERY INVERTER/CHARGER 120 2.40 L2 - 0.96 - 0.96 - 0.64 - 0.96 - 0.64 - 1.58 SEE PANEL AC-4 13 PILOT HOUSE LIGHTS (2 x 40W) 120 0.08 L1 1.00 0.08 1.00 0.08 1.00 0.08 1.00 0.08 0.50 0.04 1.00 0.08 14 DRY LAB HEATER 120 1.50 L1 0.00 0.00 1.00 1.50 0.00 0.00 0.00 0.00 1.00 1.50 0.00 0.00 15 DRY LAB LIGHTS (4 x 40W) 120 0.16 L2 1.00 0.16 1.00 0.16 1.00 0.16 1.00 0.16 0.50 0.08 1.00 0.16 16 DRY LAB OUTLETS (x2) 120 1.80 L2 0.10 0.18 0.10 0.18 0.10 0.18 0.10 0.18 0.10 0.18 0.00 0.00 17 LIFTER ROOM LIGHTS (4 x 40W) 120 0.16 L1 1.00 0.16 1.00 0.16 1.00 0.16 1.00 0.16 0.50 0.08 1.00 0.16 18 LIFTER ROOM OUTLETS (x2) 120 1.80 L1 0.05 0.09 0.05 0.09 0.05 0.09 0.05 0.09 0.05 0.09 0.00 0.00 19 LIFTER ROOM PC OUTLETS (x2) 120 1.80 L2 0.20 0.36 0.20 0.36 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20 SIMRAD TRANSCIEVER 120 2.00 L2 0.20 0.40 0.20 0.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 21 UPPER DECK EXTERIOR OUTLET (x1) 120 1.80 L1 0.05 0.09 0.05 0.09 0.05 0.09 0.00 0.00 0.00 0.00 0.00 0.00 22 DRY LAB CHEST FREEZER 120 0.50 L1 0.30 0.15 0.30 0.15 0.30 0.15 0.30 0.15 0.00 0.00 0.00 0.00 23 UPPER DK & MN DK SIDE LTS (3 x 100W) 120 0.30 L2 1.00 0.30 1.00 0.30 0.00 0.00 1.00 0.30 0.00 0.00 0.00 0.00
24 SPARE 120 L2
TOTAL (kW) 28.50 kW 8.98 kW 12.18 kW 6.55 kW 8.23 kW 3.71 kW 4.68 kW TOTAL (A) approx. 123.91 A 39.04 A 52.96 A 28.48 A 35.78 A 16.13 A 20.35 A
LF LOAD LF LOAD LF LOAD LF LOAD LF LOAD LF LOAD
1 TOILET 240 2.00 - 0.20 0.40 0.20 0.40 0.20 0.40 0.10 0.20 0.00 0.00 0.00 0.00
2 A/C STATE ROOM AHU 240 1.20 - 0.80 0.96 0.80 0.96 0.80 0.96 0.80 0.96 0.00 0.00 0.00 0.00
5 STOVE 240 9.60 - 0.00 0.00 0.00 0.00 0.05 0.48 0.00 0.00 0.00 0.00 0.00 0.00
6 A/C WALL UNITS (X3) 240 0.06 - 1.00 0.06 1.00 0.06 1.00 0.06 1.00 0.06 0.00 0.00 0.00 0.00 9 REFRIGERATOR 120 0.80 L1 0.15 0.12 0.15 0.12 0.15 0.12 0.15 0.12 0.00 0.00 0.00 0.00 10 MICROWAVE 120 1.10 L1 0.10 0.11 0.10 0.11 0.10 0.11 0.00 0.00 0.00 0.00 0.00 0.00 11 GALLEY GFCI OUTLETS (x3) 120 1.80 L2 0.10 0.18 0.10 0.18 0.10 0.18 0.10 0.18 0.10 0.18 0.00 0.00 12 GALLEY LIGHTS (3 x 40W) 120 0.12 L2 1.00 0.12 1.00 0.12 1.00 0.12 1.00 0.12 0.20 0.02 1.00 0.12 13 STATE ROOM LIGHTS (5 x 40W) 120 0.20 L1 0.10 0.02 0.10 0.02 0.10 0.02 0.10 0.02 0.20 0.04 1.00 0.20 14 STATE ROOM GFCI OUTLETS (x4) 120 1.80 L1 0.10 0.18 0.10 0.18 0.10 0.18 0.10 0.18 0.10 0.18 0.00 0.00
15 SPARE 120 L2
16 SPARE 120 L2
17 BLANK 120 L1
18 BLANK 120 L1
CI
RC
U
IT
DESCRIPTION
V HP KW
CI
RC
U
IT
DESCRIPTION
V HP KW REMARKS
PANEL AC-3 GALLEY (120/240 VAC)
SUMMER
UNDERWAY
PANEL AC-2 PILOT HOUSE (120/240 VAC)
REMARKS
SUMMER
UNDERWAY EMERGENCY
L1/L2
SPRING/FALL
UNDERWAY SHORE POWER WINTER LAYUP
HYDR. OPS,
ENGINES IDLE
L1/L2
SPRING/FALL
UNDERWAY
EMERGENCY
HYDR. OPS,
ENGINES IDLESHORE POWER WINTER LAYUP
BOKSA MARINE DESIGN, INC SHEET 3 855-835-03
19 BLANK 120 L2
20 BLANK 120 L2
21 BLANK 120 L1
22 BLANK 120 L1
23 BLANK 120 L2
24 BLANK 120 L2
TOTAL (kW) 18.68 kW 2.15 kW 2.15 kW 2.63 kW 1.84 kW 0.42 kW 0.32 kW TOTAL (A) approx. 81.23 A 9.36 A 9.36 A 11.45 A 8.01 A 1.84 A 1.39 A
LF LOAD LF LOAD LF LOAD LF LOAD LF LOAD LF LOAD
1 GOST SYSTEM & CAMERAS (x4) 120 0.40 L1 0.80 0.32 0.80 0.32 0.00 0.00 0.80 0.32 0.00 0.00 1.00 0.40 2 PILOT HOUSE OUTLETS (x2) 120 1.80 L1 0.20 0.36 0.20 0.36 0.20 0.36 0.20 0.36 0.20 0.36 0.50 0.90
3 SPARE 120 L1
4 SPARE 120 L1
5 E LIGHTS MACH SPACES (2 x 40W) 120 0.08 L1 1.00 0.08 1.00 0.08 1.00 0.08 1.00 0.08 1.00 0.08 1.00 0.08 6 E LIGHTS ACCOM & GALLEY (2 x 40W) 120 0.08 L1 1.00 0.08 1.00 0.08 1.00 0.08 1.00 0.08 1.00 0.08 1.00 0.08 7 E LIGHTS LAB, LIFTER, PH (3 x 40W) 120 0.12 L1 1.00 0.12 1.00 0.12 1.00 0.12 1.00 0.12 1.00 0.12 1.00 0.12
8 SPARE 120 L1
TOTAL (kW) 2.48 kW 0.96 kW 0.96 kW 0.64 kW 0.96 kW 0.64 kW 1.58 kW TOTAL (A) approx. 22.55 A 8.73 A 8.73 A 5.82 A 8.73 A 5.82 A 14.36 A
REMARKS
PANEL AC-4 INVERTER (120 VAC) ***FED BY PANEL AC-2***
SHORE POWERL1/L2 WINTER LAYUP
HYDR. OPS,
ENGINES IDLEKW
SUMMER
UNDERWAY
SPRING/FALL
UNDERWAY EMERGENCY
CI
RC
U
IT
DESCRIPTION
V HP
BOKSA MARINE DESIGN, INC SHEET 4 855-835-03
1 ENGINE ROOM HEATER 240 2.00 - 0.00 0.00 0.00 0.00 1.00 2.00 0.00 0.00 1.00 2.00 0.00 0.00 2 STORES HEATER 240 2.00 - 0.00 0.00 0.00 0.00 1.00 2.00 0.00 0.00 1.00 2.00 0.00 0.00 5 GALLEY HEATER OUTLET 240 2.00 - 0.00 0.00 0.00 0.00 1.00 2.00 0.00 0.00 1.00 2.00 0.00 0.00 6 LIFTER ROOM HEATER OUTLET 120 1.50 L1 0.00 0.00 0.00 0.00 0.90 1.35 0.00 0.00 0.90 1.35 0.00 0.00
8 SPARE 120
9 BLANK
10 BLANK
11 BLANK
12 BLANK
13 BLANK
14 BLANK
15 BLANK
16 BLANK
TOTAL (kW) 7.50 kW 0.00 kW 0.00 kW 7.35 kW 0.00 kW 7.35 kW 0.00 kW TOTAL (A) approx. 32.61 A 0.00 A 0.00 A 31.96 A 0.00 A 31.96 A 0.00 A
AC ELECTRICAL LOAD ANALYSIS
CI
RC
U
IT
DESCRIPTION
V HP KW REMARKS
PANEL AC-5 HEATERS (LOC: ENGINE ROOM) (120/240 VAC)
SUMMER
UNDERWAY
SPRING/FALL
UNDERWAY SHORE POWER
HYDR. OPS,
ENGINES IDLE WINTER LAYUP EMERGENCYL1/L2
BOKSA MARINE DESIGN, INC SHEET 5 855-835-03
| Title |
| Main Switchboard |
| Heater Panel |
File details come from the government source that posted it. Updated .