855-530-01-0 Fresh Water System Diagram.pdf

PDF 376 KB Posted

Attached to
MI Dept. of Natural Resources-New Fisheries Research Vessel
Solicitation number
RFP - 751 - 240000000319
Issued by
Ingham County, Lansing City, Michigan

About this file

This document is a fresh water system diagram related to a state and local contract opportunity for the construction of a new 66 ft Fisheries Research Vessel for the Michigan Department of Natural Resources (DNR). The diagram shows the piping, equipment, and layout for the fresh water system on the vessel. Key details include a 360 US gallon fresh water tank, a jet pump, water filter, water heater, and various valves and fittings. The related contract opportunity is for the build-out of the new research vessel, with bids due by 3:00 pm Eastern on February 29, 2024. The Michigan DNR will evaluate bids based on qualifications, experience, price, and completion timeline, as they are open to considering alternate completion timelines beyond the originally requested one-year timeline. An addendum has been issued extending the bid due date and clarifying the timeline flexibility.

The contract opportunity does not require performance bonds. The Michigan DNR is the procuring agency, with the vessel to be utilized within their jurisdiction as well as Ingham County and the City of Lansing. No specific pricing terms, set-asides, funding sources, or other financial details are provided in the documents reviewed.

View the file

Other files

File Type Posted
855-591-05-1 Trawl Rollers and Trawl Net Drum Arrangement and Details.pdf PDF
855-602-01-0 Outboard Profile.pdf PDF
855-180-02-0 Deck Crane Foundation Arrangement_ —
855-244-01-0 Propulsion Shaft Strut Details.pdf PDF
855-256-01-0 Engine Raw Water Cooling Diagram.pdf PDF
855-582-01-0 Mooring System Arrangement_ —
855-581-01-0 Anchoring System Arrangement_ —
855-529-01-1 Bilge_ —
855-320-02-2 DC Electrical System One-Line Diagram.pdf PDF
855-526-01-0 Scuppers and Deck Drains Diagram.pdf PDF
855-513-01-0 Machinery Space Ventilation Diagram.pdf PDF
RFP 24-0319 MI Dept of Natural Resources New Fisheries Research Vessel.docx DOCX document
855-506-01-0 Tank Vents, Fills_ —
855-591-01-0 Gut Tube Arrangement_ —
855-612-01-0 Handrail Arrangement_ —
855-259-01-0 Engine Exhaust System Diagram.pdf PDF
855-183-01-0 Generator Foundation Arrangement_ —
Attachment 1-B Example of Schedule of Values.xlsx XLSX spreadsheet
855-551-01-0 Compressed Air System Diagram.pdf PDF
855-561-01-0 Steering Gear Arrangement_ —
855-200-01-0 Propulsion System Cost Comparison.pdf PDF
855-623-01-0 Ladders Arrangement_ —
855-111-02-0 Side Shell.pdf PDF
855-131-01-0 Main Deck Structure.pdf PDF
855-201-01-0 Propulsion System Arrangement_ —
855-891-01-0 Fire_ —
855-832-01-0 Technical Specifications.pdf PDF
855-111-01-1 Bottom Shell.pdf PDF
855-566-01-0 Stabilizer Foundation Arrangement_ —
855-556-01-0 Hydraulic System Diagram.pdf PDF
855-163-01-0 Transducer Arrangement and Details.pdf PDF
855-591-03-1 Swinging Gallows Arrangement and Details.pdf PDF
855-244-02-0 Stern Tube Details.pdf PDF
855-635-01-0 Acoustic Insulation_ —
855-117-01-0 Typical Transverse Frames_ —
855-583-01-0 Life Raft Foundation Arrangement_ —
855-540-01-0 Fuel System Diagram.pdf PDF
855-640-01-1 Lower Deck Soles Arrangement_ —
855-560-01-0 Bow Thruster Arrangement and Details.pdf PDF
855-422-01-0 Navigation Lights Arrangement.pdf PDF
855-604-01-0 Hull Markings_ —
855-603-01-P2 Inboard Profile.pdf PDF
855-625-01-0 Windows Arrangement_ —
855-168-01-0 Weathertight Doors.pdf PDF
855-843-02-R0 Stability Test Procedure - Inclining.pdf PDF
855-835-04-2 DC Electrical Load Analysis_ —
Attachment 1-A MI DNR Research Vessel - Resume Template.docx DOCX document
855-167-01-1 Watertight Doors and Hatches.pdf PDF
RFP 24-0319 MI DNR Reseach Vessel Buld-ADDENDUM #1 Stabilizer.docx DOCX document
855-180-01-0 Trawl Winch Foundation Arrangement_ —
Show 40 more

Latest 50 of 64 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

D

C

B

A

E

D

C

B

A

8 7 6 5 4 3 2 1

8 7 6 5 4 3 2 1

PROPRIETARY INFORMATION THIS DOCUMENT IS PROPRIETARY. NO DATA OR DESIGN SHALL BE COPIED, REPRODUCED, DISCLOSED OR SUBMITTED TO ANY THIRD PARTY, OR USED FOR CONSTRUCTION OR MANUFACTURE, IN WHOLE OR IN PART, OF ANY PRODUCT DEFINED WITHOUT PRIOR WRITTEN CONSENT OF BOKSA MARINE DESIGN, INC., LITHIA, FL 33547 - U.S.A.

16627 Fishhawk Blvd.

Suite 101

Lithia, FL 33547

(813) 654-9800 www.bmdinc.com

AutoCAD SHX Text P

AutoCAD SHX Text

ENGINE ROOM

AutoCAD SHX Text

STORES

AutoCAD SHX Text

ACCOMODATIONS

AutoCAD SHX Text

GALLEY

AutoCAD SHX Text

FOREPEAK

AutoCAD SHX Text

CUT IN: 30 PSI CUT OUT: 50 PSI

AutoCAD SHX Text

SET 60 PSI

AutoCAD SHX Text T

AutoCAD SHX Text P

AutoCAD SHX Text 1"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text

SEE NOTE 5

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text

SHOWER

AutoCAD SHX Text

HEAD SINK

AutoCAD SHX Text

UP TO LAB SINK

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text

GALLEY SINK

AutoCAD SHX Text

UP TO ICE MAKER

AutoCAD SHX Text

WATER HEATER

AutoCAD SHX Text

PRESSURE TANK

AutoCAD SHX Text

FILTER

AutoCAD SHX Text

FRESH WATER TANK 360 US GAL

AutoCAD SHX Text

DRAIN

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

APPD

AutoCAD SHX Text

DWG NUMBER

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

REV

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

FRESH WATER SYSTEM DIAGRAM

AutoCAD SHX Text

JHP

AutoCAD SHX Text 9/18/2023

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text 855-530-01

AutoCAD SHX Text

TITLE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

AutoCAD SHX Text

RESEARCH VESSEL

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

REV.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

AutoCAD SHX Text

RELEASE FOR DESIGN PACKAGE

AutoCAD SHX Text

JHP

AutoCAD SHX Text 9/18/23

AutoCAD SHX Text

REFERENCES

AutoCAD SHX Text

ITEM

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

AutoCAD SHX Text 855-506-01

AutoCAD SHX Text

TANK VENTS, FILLS AND SOUNDS DIAGRAM

AutoCAD SHX Text

CHARLEVOIX FISHERIES RESEARCH STATION 96 GRANT ST. CHARLEVOIX, MI 49720

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1. VESSEL TO BE CONSTRUCTED IN ACCORDANCE WITH ALL USCG UNINSPECTED VESSEL VESSEL TO BE CONSTRUCTED IN ACCORDANCE WITH ALL USCG UNINSPECTED VESSEL RULES AND REGULATIONS. 2. THIS DIAGRAM REPRESENTS APPROXIMATE EQUIPMENT LOCATIONS AND ROUTING. THIS DIAGRAM REPRESENTS APPROXIMATE EQUIPMENT LOCATIONS AND ROUTING. SHIPYARD TO DEVELOP DETAIL EQUIPMENT FOUNDATIONS AND PIPE ROUTING AS APPROPRIATE. 3. PIPING SHALL BE RUN AS DIRECTLY AS PRACTICABLE WITH A MINIMUM NUMBER OF PIPING SHALL BE RUN AS DIRECTLY AS PRACTICABLE WITH A MINIMUM NUMBER OF BENDS AND FITTINGS. POCKETS SHALL BE AVOIDED. 4. ALL PIPING SYSTEMS SHALL BE CLEANED AND HYDROSTATICALLY TESTED AFTER ALL PIPING SYSTEMS SHALL BE CLEANED AND HYDROSTATICALLY TESTED AFTER COMPLETION TO 1.5 TIMES WORKING PRESSURE. 5. A DRAIN SHALL BE PROVIDED AT SYSTEM LOW POINTS. AT LEAST ONE DRAIN SHALL A DRAIN SHALL BE PROVIDED AT SYSTEM LOW POINTS. AT LEAST ONE DRAIN SHALL EXIST IN THE MAIN HOT AND COLD WATER LINES. 6. ALL HOT WATER PIPING SHALL BE INSULATED WITH 1" FIBERGLASS AND VAPOR ALL HOT WATER PIPING SHALL BE INSULATED WITH 1" FIBERGLASS AND VAPOR BARRIER. 7. PIPING IN ACCOMMODATION SPACES SHALL BE RUN BEHIND JOINER WHERE POSSIBLE, PIPING IN ACCOMMODATION SPACES SHALL BE RUN BEHIND JOINER WHERE POSSIBLE, WITH ACCESS PANELS AT VALVES. 8. SINK, SHOWER, AND ICE MACHINE CONNECTION DETAILS SHALL BE VERIFIED BEFORE SINK, SHOWER, AND ICE MACHINE CONNECTION DETAILS SHALL BE VERIFIED BEFORE PIPING CONSTRUCTION.

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

SYMBOL KEY

AutoCAD SHX Text

FRESH WATER PIPE

AutoCAD SHX Text

BALL VALVE

AutoCAD SHX Text

SWING CHECK VALVE

AutoCAD SHX Text

DRAIN VALVE W PLUG

AutoCAD SHX Text

PRESSURE RELIEF VALVE

AutoCAD SHX Text

TEMP & PRESS RELIEF VALVE

AutoCAD SHX Text

HOT WATER PIPE

AutoCAD SHX Text

PIPE UP

AutoCAD SHX Text

PENETRATION

AutoCAD SHX Text

PRESSURE GAUGE

AutoCAD SHX Text

MATERIAL SCHEDULE

AutoCAD SHX Text

SERVICE

AutoCAD SHX Text

PRESSURE

AutoCAD SHX Text

PIPING

AutoCAD SHX Text

TAKEDOWN JOINTS

AutoCAD SHX Text

VALVES

AutoCAD SHX Text

FITTINGS

AutoCAD SHX Text

FLEXIBLE CONNECTION

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

GASKETS

AutoCAD SHX Text

BOLTING

AutoCAD SHX Text

BODY

AutoCAD SHX Text

TRIM

AutoCAD SHX Text

FRESH WATER FILL, VENT, AND PUMP SUCTION

AutoCAD SHX Text

WORKING PRESSURE 50 PSIG DESIGN PRESSURE 64 PSG TEST PRESSURE 96 PSIG

AutoCAD SHX Text

ALL

AutoCAD SHX Text

316 STAINLESS STEEL, SCH. 40 ASTM A312 ERW OR SEAMLESS ANSI B36.10

AutoCAD SHX Text UNION, SCRD 316 STAINLESS STEEL, ASTM A182 3000# OR FLANGE, 150# 316 STAINLESS STEEL, ASTM A182 ANSI B16.5 SLIP-ON OR WELD NECK

AutoCAD SHX Text

EPDM RUBBER ASTM D1331

AutoCAD SHX Text BOLTS: STAINLESS STEEL ASTM A193, GR B8M ANSI B18.2.1 NUTS: STAINLESS STEEL ASTM A194, GR 8M ANSI B18.2.2

AutoCAD SHX Text BALL: STAINLESS STEEL ASTM A182 THREADED SWING CHECK: STAINLESS STEEL ASTM A182 THREADED

AutoCAD SHX Text

BALL: CHROME PLATED STEEL BALL RPTFE SEATS SWING CHECK: SS DISC

AutoCAD SHX Text

THD OR SOCKET WELD LONG RAD. SCH. 80 CARBON STEEL ASTM A234 GR WCB ANSI B16.11

AutoCAD SHX Text

SUPPLIED WITH EQUIPMENT

AutoCAD SHX Text

AutoCAD SHX Text

FRESH WATER ALL PIPE AFTER PUMP DISCHARGE

AutoCAD SHX Text

ALL

AutoCAD SHX Text

COPPER, TYPE K HARD DRAWN SEAMLESS ASTM B88

AutoCAD SHX Text

WROUGHT COPPER SOLDER JOINT OR CAST BRONZE UNION ASTM SB88, TYPE K ANSI B16.22

AutoCAD SHX Text

BALL: BRONZE ASTM B62 THREADED SWING CHECK: BRONZE ASTM B62 THREADED

AutoCAD SHX Text

BENT TUBING OR WROUGHT COPPER OR CAST BRONZE ASTM SB88, TYPE K ANSI B16.22

AutoCAD SHX Text

EQUIPMENT LIST

AutoCAD SHX Text

QTY.

AutoCAD SHX Text

SERVICE

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

CAPACITY

AutoCAD SHX Text

DRIVE

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

AutoCAD SHX Text

FRESH WATER PUMP

AutoCAD SHX Text

JET PUMP

AutoCAD SHX Text

GOULDS JRS5 1-1/4" IN, 1" OUT CAST IRON BODY

AutoCAD SHX Text

13.3 GPM @ 50 PSI, 64 PSI SHUTOFF PRESSURE

AutoCAD SHX Text

240 V, 1 PH 1/2 HP MOTOR 3500 RPM

AutoCAD SHX Text

SUPPLIED WITH PRESSURE SWITCH, 30/50 PSI CUT IN/OUT

AutoCAD SHX Text

AutoCAD SHX Text

ACCUMULATOR TANK

AutoCAD SHX Text

STEEL

AutoCAD SHX Text

AutoCAD SHX Text

APPROX. 1 GAL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WATER FILTER

AutoCAD SHX Text

CARTRIDGE

AutoCAD SHX Text

3M AQUA-PURE MFR # 5621104 OR SIM.

AutoCAD SHX Text

5 MICRON, 20 GPM, 100,000 GAL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WATER HEATER

AutoCAD SHX Text

TANKED WATER HEATER

AutoCAD SHX Text

A.O. SMITH ENS-40 OR SIM.

AutoCAD SHX Text

40 GAL

AutoCAD SHX Text

240 V, 1 PH 6000 W MAX

AutoCAD SHX Text

AutoCAD SHX Text

FRESH WATER DIAGRAM BELOW MAIN DECK NOT TO SCALE

AutoCAD SHX Text

PENETRATION DETAIL FOR COPPER PIPE, USE FOR ALL STEEL PENETRATIONS NOT TO SCALE

AutoCAD SHX Text

1" OR 1/2" COPPER PIPE

AutoCAD SHX Text

SCH. 80 PIPE SLEEVE

AutoCAD SHX Text

FIRE STOP

AutoCAD SHX Text

BULKHEAD OR DECK

AutoCAD SHX Text T/2

AutoCAD SHX Text P

AutoCAD SHX Text T

AutoCAD SHX Text P

AutoCAD SHX Text

REDUCER

AutoCAD SHX Text

GATE VALVE, FLANGED

AutoCAD SHX Text

SIMPLEX STRAINER

AutoCAD SHX Text

PIPE DOWN

AutoCAD SHX Text

SEE REF 1 FOR TANK VENT, FILL AND SOUND

AutoCAD SHX Text

Sheets and Views
855-530-01-Working Fresh Water System Diagram-SH 1

File details come from the government source that posted it. Updated .