855-640-01-1 Lower Deck Soles Arrangement_
310 KB Posted
- Solicitation number
- RFP - 751 - 240000000319
- Issued by
- Ingham County, Lansing City, Michigan
About this file
This document appears to be a technical drawing and related materials for the Lower Deck Soles Arrangement of a Research Vessel project. The project is being conducted by the Charlevoix Fisheries Research Station, located at 96 Grant St., Charlevoix, MI 49720. The drawing provides details on the layout and construction of the lower deck sole support structure, including the use of perimeter angles, stanchions, and welding pads. References are made to other related drawings, such as the Bottom Shell Structure, Inboard Profile, and Transducer Arrangement.
The related state and local contract opportunity is for the build-out of a new 66 ft Fisheries Research Vessel for the State of Michigan Department of Natural Resources (MI DNR). The bid submission deadline has been extended to Thursday, February 29, 2024, at 3:00 p.m. Eastern Time. Bidders are requested to submit a proposed alternate timeline if unable to meet the requested one-year completion date, as the MI DNR will evaluate all bids based on qualifications, experience, dollar value, and best-fit completion date. An addendum has been issued to add the SEAKEEPER Specification to the Bid Documents.
Text of this file
E
D
C
B
A
E
D
C
B
A
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
PROPRIETARY INFORMATION THIS DOCUMENT IS PROPRIETARY. NO DATA OR DESIGN SHALL BE COPIED, REPRODUCED, DISCLOSED OR SUBMITTED TO ANY THIRD PARTY, OR USED FOR CONSTRUCTION OR MANUFACTURE, IN WHOLE OR IN PART, OF ANY PRODUCT DEFINED WITHOUT PRIOR WRITTEN CONSENT OF BOKSA MARINE DESIGN, INC., LITHIA, FL 33547 - U.S.A.
16627 Fishhawk Blvd.
Suite 101
Lithia, FL 33547
(813) 654-9800 www.bmdinc.com
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPD
AutoCAD SHX Text
DWG NUMBER
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
REV
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
LOWER DECK SOLES ARRANGEMENT & DETAILS
AutoCAD SHX Text
OS
AutoCAD SHX Text 10/25/2023
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text 855-640-01
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
AutoCAD SHX Text
RESEARCH VESSEL
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AutoCAD SHX Text
RELEASE FOR DESIGN PACKAGE
AutoCAD SHX Text
OS
AutoCAD SHX Text 9/20/2023
AutoCAD SHX Text
AutoCAD SHX Text
BOW THRUSTER LOCATION
AutoCAD SHX Text
OS
AutoCAD SHX Text 10/25/2023
AutoCAD SHX Text
CHARLEVOIX FISHERIES RESEARCH STATION 96 GRANT ST. CHARLEVOIX, MI 49720
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LOWER DECK SOLE STANCHION LAYOUT PLAN VIEW SCALE: " = 1'-0"34" = 1'-0"
AutoCAD SHX Text PERIMETER ANGLE: 1 "x1 "x " L TYP12"x1 "x " L TYP12"x " L TYP316" L TYP
AutoCAD SHX Text
1. THIS DRAWING IS INTENDED TO BE USED AS A GUIDELINE FOR LAYING OUT THE THIS DRAWING IS INTENDED TO BE USED AS A GUIDELINE FOR LAYING OUT THE LAZERETTE SOLE SUPPORT STRUCTURE. 2. VERIFY ALL DIMENSIONS PRIOR TO FABRICATION & INSTALLATION. VERIFY ALL DIMENSIONS PRIOR TO FABRICATION & INSTALLATION. 3. ALL UNITS ARE IN FEET AND INCHES. ALL UNITS ARE IN FEET AND INCHES. 4. ALL WELDING, MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH ABS ALL WELDING, MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH ABS RULES FOR BUILDING "STEEL VESSELS UNDER 90 METERS IN LENGTH". 5. ALL STEEL TO BE ABS GRADE A, MIN. YIELD STRENGTH 34ksi OR BETTER. ALL STEEL TO BE ABS GRADE A, MIN. YIELD STRENGTH 34ksi OR BETTER. 6. REMOVABLE PANELS IN GALLEY, HEAD, AND LOCKERS AS REQUIRED FOR ACCESS. REMOVABLE PANELS IN GALLEY, HEAD, AND LOCKERS AS REQUIRED FOR ACCESS. 7. REMOVABLE PANELS REQUIRED IN WAY OF GRAY WATER TANK. REMOVABLE PANELS REQUIRED IN WAY OF GRAY WATER TANK.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
REFERENCES
AutoCAD SHX Text
DWG NO.
AutoCAD SHX Text
DRAWING NAME
AutoCAD SHX Text
AutoCAD SHX Text 855-111-01
AutoCAD SHX Text
BOTTOM SHELL STRUCTURE
AutoCAD SHX Text
AutoCAD SHX Text 855-603-01
AutoCAD SHX Text
INBOARD PROFILE
AutoCAD SHX Text
AutoCAD SHX Text 855-163-01
AutoCAD SHX Text
TRANSDUCER ARRANGEMENT AND DETAILS
AutoCAD SHX Text
14" BHD
AutoCAD SHX Text
SOLE GRID
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DETAIL B-7 TYPICAL DECK SOLE STANCHION SCALE: 3" = 1'-0"
AutoCAD SHX Text
SOLE PANEL (FINISHED SOLE)
AutoCAD SHX Text WELDING PAD: 2 "x2 "x " 12"x2 "x " 12"x " 316" PL
AutoCAD SHX Text STANCHION: 1 "x1 "x " L (TYP)12"x1 "x " L (TYP)12"x " L (TYP)316" L (TYP) L (TYP)
AutoCAD SHX Text
SEE DETAIL B-7
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
38" PLT
AutoCAD SHX Text 4x " FLG38" FLG
AutoCAD SHX Text
TYPICAL SECTION B-6 FRAME 12 LOOKING AFT SCALE: " = 1'-0"12" = 1'-0"
AutoCAD SHX Text
14" CHAMFER
AutoCAD SHX Text
COLUMNS CENTERED ON FLANGE (TYP)
AutoCAD SHX Text
SEE DETAIL B-3
AutoCAD SHX Text
KEEL
AutoCAD SHX Text
516" SHELL
AutoCAD SHX Text
CVK
AutoCAD SHX Text 3x " FLG14" FLG
AutoCAD SHX Text STANCHION TOP PL.: 4 "x4 "x " PL. (TYP)12"x4 "x " PL. (TYP)12"x " PL. (TYP)316" PL. (TYP)
AutoCAD SHX Text
14" BHD
AutoCAD SHX Text
DETAIL D-1 PERIMETER ANGLE SCALE: 1" = 1'-0"
AutoCAD SHX Text
54" ABL TO TOP OF SOLE
AutoCAD SHX Text
36" ABL TO TOP OF SOLE
AutoCAD SHX Text
14" BHD
AutoCAD SHX Text
COLUMNS CENTERED ON FLANGE (TYP)
O
AutoCAD SHX Text 32"
AutoCAD SHX Text 64"
AutoCAD SHX Text 32"
AutoCAD SHX Text 64"
AutoCAD SHX Text
SEE DETAIL B-7
AutoCAD SHX Text
FINISHED SOLE
AutoCAD SHX Text
TYPICAL SECTION B-4 FRAME 7 LOOKING AFT SCALE: " = 1'-0"12" = 1'-0"
KEEL
AutoCAD SHX Text
516" SHELL
AutoCAD SHX Text
CVK
AutoCAD SHX Text 3x " FLG14" FLG
AutoCAD SHX Text
COLUMNS CENTERED ON FLANGE (TYP)
O
AutoCAD SHX Text 32"
AutoCAD SHX Text 64"
AutoCAD SHX Text 32"
AutoCAD SHX Text 64"
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text
SEE DETAIL B-3
14" CHAMFER
AutoCAD SHX Text
DETAIL C-1 PERIMETER ANGLE FWD LOWER DECK SCALE: 1" = 1'-0"
AutoCAD SHX Text
FINISHED SOLE
AutoCAD SHX Text
SOLE GRID
AutoCAD SHX Text
PLYWOOD LEVELING PAD
AutoCAD SHX Text PERIMETER ANGLE: 1 "x1 "x " L TYP12"x1 "x " L TYP12"x " L TYP316" L TYP
AutoCAD SHX Text PERIMETER ANGLE: 1 "x1 "x " L TYP12"x1 "x " L TYP12"x " L TYP316" L TYP
AutoCAD SHX Text
GRAY WATER TANK
AutoCAD SHX Text
SEE REFERENCE FOR TRASDUCER WELL DETAILS
AutoCAD SHX Text
TRANSDUCER LOCATION
BOW THRUSTER ACCESS