800A_to_400A_DS-A4BY-Class-L-Time-Delay-Mersen.pdf
PDF 174 KB Posted
- Attached to
- Theater Lighting Renovations
- Solicitation number
- 26-CD-020
- Issued by
- Pinellas County, Florida
About this file
This is a product specification document for Mersen A4BY Class L power fuses applicable to the Pinellas County School District's Theater Lighting Renovations project in Florida. The A4BY fuses are UL/CSA-listed devices designed for protecting service entrance equipment, feeder circuits, and circuit breakers in applications including mains, feeders, load centers, panelboards, switchboards, and metering centers. The fuses are available in ampere ratings ranging from 200 to 6000A for AC applications (200 to 2500A for DC), with voltage ratings of 600VAC and 300VDC. The A4BY fuses feature a 4-second minimum time delay at 500% rating, current limiting capability, and a high interrupting rating of 200kA for AC and 100kA for DC. These devices are 100% rated and may be applied at continuous currents up to their ampere rating, allowing them to pass normal current surges and coordinate with ground fault relays.
The specification document provides detailed catalog numbers for fuses in amperage ranges from 200-800A through 4001-6000A, along with comprehensive dimensional data in both inches and millimeters for proper installation. Recommended fuse blocks for Class L fuses are identified, with catalog number P48F designated as UL recognized for ratings of 100-800A at 600V or less in 3-pole configurations, and catalog number P412F self-certified for 801-1200A ratings. The document notes that Class L fuses are dimensioned for one-way interchangeability, allowing substitution of lower ampere rating fuses for higher ones. Optional blown fuse trigger indicators are available upon request by adding "-TI" to the part number. The fuses comply with UL standard 248-10 and CSA standard C22.2 No. 248.10 for ratings from 601-6000A.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MERSEN.COM PF 4
M er se n.
A ll ri g ht s re se rv ed
. M er se n re se rv es t he r ig ht t o c ha ng e, u p d at e, o r co rr ec t, w it ho ut n o ti ce
, a ny in fo rm at io n co nt ai ne d in t hi s d at as he et
A4BY
Class L
UL/CSA L ISTED POWER FUSES
COUNT ON THE HIGH INTERRUPTING RATING
OF OUR MOST WIDELY USED CLASS L FUSE
When it comes to protecting service entrance equipment, feeder circuits, and circuit breakers, A4BY fuses are the industry’s favorite.
The A4BY is a 100% rated device and may be applied at continuous currents up to its ampere rating. A 4-second minimum time delay at 500% rating allows the A4BY to pass normal current surges and to coordinate with ground fault relays.
FEATURES/BENEFITS
• Unique dimensions prevent replacement by other fuse classes
• Blade stamped catalog numbers for permanent identification
• Glass melamine body and plated terminals provide superior reliability in harsh environments
RATINGS
• Volts: 600VAC, 300VDC
• Amps: 200 to 6000A (AC), 200 to 2500A (DC)
• I.R.: 200kA I.R. AC, 100kA I.R. DC
HIGHLIGHTS
• Current limiting
• 4-second time delay
• DC ratings
• Uniform characteristics in all ampere ratings
APPLICATIONS
• Mains, feeders
• Circuit breakers
• Load centers
• Panelboards
• Switchboards
• Metering centers
APPROVALS/STANDARDS
• UL listed to standard 248-10
(601-6000A) File E2137
• CSA certified to standard C22.2 No. 248.10 (601-6000A)
• Self-certified for DC per
UL248 (601-6000A)
MERSEN.COM PF 5
M er se n.
A ll ri g ht s re se rv ed
. M er se n re se rv es t he r ig ht t o c ha ng e, u p d at e, o r co rr ec t, w it ho ut n o ti ce
, a ny in fo rm at io n co nt ai ne d in t hi s d at as he et
UL/CSA L ISTED
POWER FUSES
CATALOG NUMBERS (AMPS)
DIMENSIONS
200-800A 801-2000A
3001-4000A
2001-3000A
4001-6000A
Note: For optional blown fuse trigger indicator add “-TI” to the end of part number. Example: A4BY1600-TI.
Consult factory for availability.
A4BY200 A4BY700 A4BY1350 A4BY2500
A4BY250 A4BY750 A4BY1400 A4BY3000
A4BY300 A4BY800 A4BY1500 A4BY3001
A4BY350 A4BY801 A4BY1600 A4BY3500
A4BY400 A4BY900 A4BY1601 A4BY4000
A4BY450 A4BY1000 A4BY1800 A4BY4001
A4BY500 A4BY1100 A4BY2000 A4BY4500
A4BY600 A4BY1200 A4BY2001 A4BY5000
A4BY601 A4BY1201 A4BY2200 A4BY6000
A4BY650
RECOMMENDED FUSE BLOCKS FOR
AMP-TRAP® CLASS L FUSES
Catalog number P48F is UL recognized Catalog number P412F is self-certified
A variety of pole configurations and termination provisions are available. Refer to Section FB for details.
Fuse Ampere Rating Catalog Number 600V or Less 3-Pole
100-800 P48F
801-1200 P412F
Ampere Rating
A B C D E in mm in mm in mm in mm in mm
200-600 8-5/8 219 2 51 5/16 8 1-5/8 41 2-13/32 61
601-800 8-5/8 219 2-1/2 63 3/8 9 2 51 2-13/32 61
801-1200 10-3/4 273 2-1/2 63 3/8 9 2 51 3-15/32 88
1201-1600 10-3/4 273 3 76 7/16 11 2-3/8 60 3-15/32 88
1601-2000 10-3/4 273 3-1/2 89 1/2 13 2-3/4 70 3-15/32 88
2001-2500 10-3/4 273 4-1/2 114 3/4 19 3-1/2 89 3-15/32 88
2501-3000 10-3/4 273 5 127 3/4 19 4 102 3-15/32 88
3001-4000 10-3/4 273 5-3/4 146 3/4 19 4-3/4 121 3-15/32 88
4001-5000 10-3/4 273 6-1/4 159 1 25 5-1/4 133 3-15/32 88
5001-6000 10-3/4 273 7-1/8 181 1 25 5-3/4 146 3-15/32 88
A4BY
Class L
Safety Note: Class L fuses are dimensioned for one-way interchangeability.
A Class L fuse of any lower ampere rating can be substituted for a given Class L fuse.