7ME653_FMS500.pdf

PDF 663 KB Posted

Attached to
SWWRF QTY two (2) Siemens SITRANS Flow Meter Transmitters and Accessories.
Solicitation number
Quote- 26 - 313
Issued by
Pinellas County, Florida

About this file

Summary of 7ME653_FMS500.pdf

This document is a specification sheet or technical data file for the City of St. Petersburg, Florida, related to the procurement of Siemens SITRANS Flow Meter Transmitters for the Southwest Water Reclamation Facility (SWWRF). The city is seeking to acquire two flow meter units with compatible coupling accessories designed to monitor raw sewage flow in separate headworks influent pipelines: one transmitter for a 20-inch influent pipe and one for a 30-inch influent pipe. These new meters will replace obsolete equipment that has exceeded its service life. The SITRANS technology upgrade is intended to improve measurement accuracy, reliability, maintainability, and long-term parts availability to support continued efficient facility operations.

The specification file details the technical requirements, performance standards, and product configurations necessary for the flow meter transmitters and associated accessories. The procurement represents a capital equipment replacement project for critical wastewater treatment infrastructure monitoring. Specific pricing terms, contract duration, delivery timelines, and award information are governed by the formal procurement solicitation documents associated with this opportunity. The project prioritizes compatibility with existing SWWRF infrastructure and adherence to the operational requirements of the wastewater treatment facility's headworks systems.

View the file

Other files

File Type Posted
SWWRF_QTY_two_(2)_Siemens_SITRANS_Flow_Meter_Transmitters_and_Accessories..pdf PDF
Agreement_.pdf PDF
FMT020_Datasheet_8-5-25.pdf PDF
Flow-meters_photos.docx DOCX document
Public_Construction_Bond.docx DOCX document
Light_Construction_Agreement.docx DOCX document
Quote_Q285836_1784655211492.pdf PDF
Subcontractor_Summary_Spreadsheet.xlsx XLSX spreadsheet
Performance_&_Payment_Bond_.DOCX DOCX document
Subcontractor_Utilization_Plan.docx DOCX document
Subcontractor_Summary_-_Sheltered_.xlsx XLSX spreadsheet
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Flow sensors

SITRANS FMS500

3/37

Overview

The SITRANS FMS500 is a magnetic flowmeter sensor suitable for volume flow measurement of liquids (conductive) and is the ideal product for applications in water abstraction, wastewater treatment, water distribution networks, and irrigation.

The rugged, fully welded design supports direct burial, constant flooding and to stand up a wide range of harsh chemicals found in water-based applications in many different industries.

Designed for highly accurate measurement in low-flow conditions, these meters can measure from very low velocities up to 10 m/s, giv ing it a very wide measurement range.

Combined with a flowmeter transmitter it is a traditional externally powered electromagnetic flowmeter system

Benefits

• Zero Up and Zero Down installation capabilities

• NBR rubber liner for all water and wastewater applications

• EPDM liner specifically for drinking water applications requiring special approvals

• Soft elastomer facing provides high abrasion resistance

• Increased low flow accuracy for water leak detection

• Rugged construction with no moving parts for maintenance-free operation over many years

• Simple on-site upgrade to IP68 of a standard sensor allowing underground installation, permanent immersion or underwater installation

• Integrated grounding electrodes – no grounding rings required for many applications

• Short delivery time

• Built-in length according to ISO 20456 (up to DN 400 mm)

• SENSORPROM™ Technology provides an automatic upload of start-up settings and calibration data for easy commissioning

• Designed to allow in-situ verification for easy performance check

• In conformity with ISO 4064, OIML R49 and EN 14154

• Custody transfer approvals for cold water billing (MI-001)

Application

• Water abstraction

• Water treatment

• Water distribution network (leak detection management)

• Custody transfer water meters

• Irrigation

• Waste water treatment

• Filtration plant (e.g. reverse osmosis and ultra-filtration)

• Industrial water applications

The SITRANS FMS500 with its NBR or EPDM rubber lining is a flow meter sensor for all kinds of water applications such as ground water, potable water, cooling water, wastewater, sewage, or sludge applications.

Connected to the compatible transmitter SITRANS FMT020, either mounted remotely or as a compact unit, it forms the magnetic flow meter system SITRANS FM520 which can be used in almost all gen eral-purpose water applications.

SITRANS FM520

Perfect match for a cost-effective solution for all water and wastewa ter applications. Standard measuring accuracy ±0.4% of the actual flow rate, optional a high accuracy calibration with ±0.2% of flow actual rate is available.

Siemens FI 01 · 2025

SITRANS FM (electromagnetic)

© Siemens AG 2025

Update 09/2025

SITRANS FMS500

Selection and ordering data

Article No.

Sensor SITRANS FMS500 7ME653-

• - • • • • • - 1 • A • Click on the Article No. for the online configuration in the PIA Life Cycle Portal.

Transmitter variant No transmitter (sensor only) 0 Transmitter SITRANS FMT020 2 Diameter DN 15, ½ inch 1 V DN 25, 1 inch 2 D DN 40, 1½ inch 2 R DN 50, 2 inch 2 Y DN 65, 2½ inch 3 F DN 80, 3 inch 3 M DN 100, 4 inch 3 T DN 125, 5 inch 4 B DN 150, 6 inch 4 H DN 200, 8 inch 4 P DN 250, 10 inch 4 V DN 300, 12 inch 5 B DN 350, 14 inch 5 D DN 400, 16 inch 5 H DN 450, 18 inch 5 K DN 500, 20 inch 5 R DN 600, 24 inch 5 Y DN 700, 28 inch 6 B DN 750, 30 inch 6 D DN 800, 32 inch 6 H DN 900, 36 inch 6 K DN 1000, 40 inch 6 R DN 1050, 42 inch 6 Y DN 1100, 44 inch 7 D DN 1200, 48 inch 7 H DN 1400, 54 inch 7 M DN 1500, 60 inch 7 R DN 1600, 64 inch 7 V DN 1800, 72 inch 7 Y DN 2000, 80 inch 8 B Process connection EN 1092-1 PN 6 flanges A EN 1092-1 PN 10 flanges B EN 1092-1 PN 16 flanges (PED compliant) C EN 1092-1 PN 16 flanges, non-PED type of equipment (excluded from scope of PED 2014/68/EU) D EN 1092-1 PN 40 flanges F ANSI B16.5 Class 150 flanges J AWWA C-207 Class D flanges M AS 4087 PN 16 flanges S JIS B 2220:2004 10K flanges W Process connection material Carbon steel ASTM A 105 with corrosion-resistant coating acc. to EN ISO 12944 grade C4 0 Carbon steel ASTM A 105 with corrosion-resistant coating acc. to EN ISO 12944 grade C5 (300 μm) 1 Liner material

EPDM 2

NBR 3

Electrode material Hastelloy C276 / 2.4819 1 Transmitter mounting & enclosure type No transmitter (sensor only) A Compact design (integral mount), polycarbonate enclosure G Remote design, polycarbonate enclosure (wall-mounting unit and sensor terminal board included) J

Flow sensors SITRANS FM (electromagnetic)

3/38 Siemens FI 01 · 2025

© Siemens AG 2025 https://www.pia-portal.automation.siemens.com/SIE/Z3_PIA_Portal/?sap-language=EN&P_MATNR=7ME653*

Selection and ordering data (continued)

Article No.

Sensor SITRANS FMS500 7ME653-

• - • • • • • - 1 • A • Power supply None (sensor only) 0

12 … 42 V DC 2

100 … 240 V AC, 50/60 Hz 3

1) Not concerned by PED

Additional information Order code Please add "-Z" to Article No. and specify Order code(s) and plain text.

Cable glands Without cable glands (blind plugs) A00 M20x1.5 cable glands, material polyamide A02 M20x1.5 cable glands, Ex, material polyamide A03 1/2 inch NPT cable glands, material polyamide A05 1/2 inch NPT cable glands, Ex, material polyamide A06 Certificates Declaration of compliance with the order 2.1 (EN 10204) C00 Inspection certificate 3.1 (EN 10204) - Material of pressure-containing and wetted parts

C12

Test report 2.2 (EN 10204) C14 Inspection certificate 3.1(EN 10204) - Pressure test C18 High accuracy calibration High accuracy calibration +/- 0.2% of the act. vol. flow, DN ≤ 200, ≤ 8 inch

D01

High accuracy calibration +/- 0.2% of the act. vol. flow, DN 250 … 600, 10 … 24 inch

D02

High accuracy calibration +/- 0.2% of the act. vol. flow, DN 700 … 1200, 28 … 48 inch

D03

High accuracy calibration +/- 0.2% of the act. vol. flow, DN ≥ 1400, ≥ 54 inch

D04

5-point calibration 5-point factory calibration, DN ≤200, ≤ 8 inch D10 5-point factory calibration, DN 250 … 600, 10 … 24 inch D11 5-point factory calibration, DN 700 … 1200, 28 … 48 inch D12 5-point factory calibration, DN ≥ 1400, ≥ 54 inch D13 10-point calibration 10-point factory calibration, DN ≤ 200, ≤ 8 inch D15 10-point factory calibration, DN 250 … 600, 10 … 24 inch D16 10-point factory calibration, DN 700 … 1200, 28 … 48 inch D17 10-point factory calibration, DN ≥ 1400, ≥ 54 inch D18 Default matched-pair calibration Default matched-pair factory calibration, DN ≤ 200, ≤ 8 inch D20 Default matched-pair factory calibration, DN 250 … 600, 10 … 24 inch

D21

Default matched-pair factory calibration, DN 700 … 1200, 28 …48 inch

D22

Default matched-pair factory calibration, DN ≥ 1400, ≥ 54 inch D23 5-point matched-pair calibration 5-point, matched-pair factory calibration, DN ≤ 200, ≤ 8 inch D25 5-point, matched-pair factory calibration, DN 250 … 600, 10 … 24 inch

D26

5-point, matched-pair factory calibration, DN 700 … 1200, 28 … 48 inch

D27

5-point, matched-pair factory calibration, DN ≥ 1400, ≥ 54 inch D28 10-point matched-pair calibration 10-point, matched-pair factory calibration, DN ≤ 200, ≤ 8 inch D30 10-point, matched-pair factory calibration, DN 250 … 600, 10 … 24 inch

D31

Additional information Order code 10-point, matched-pair factory calibration, DN 700 … 1200, 28 …48 inch

D32

10-point, matched-pair factory calibration, DN ≥ 1400, ≥ 54 inch

D33

Accredited ISO/IEC 17025 calibration ISO/IEC 17025 accredited, 5-point, matched-pair factory calibration, DN ≤ 200, ≤ 8 inch

D35

ISO/IEC 17025 accredited, 5-point, matched-pair factory calibration, DN 250 … 600, 10 …24 inch

D36

ISO/IEC 17025 accredited, 5-point, matched-pair factory calibration, DN 700 … 1200, 28 … 48 inch

D37

ISO/IEC 17025 accredited, 5-point, matched-pair factory calibration, DN ≥ 1400, ≥ 54 inch

D38

General safety CSA General Purpose E06 Explosion protection ATEX (Europe) & IECEx (World) E20 FM (USA & Canada) E22 IECEx (World) E23 Country specific approvals CPA (China) E75 Drinking water approvals WRAS (WRc, BS 6920, GB) E80 NSF/ANSI 61 (Cold water, US) E81 ACS (France) E82 Compliance to Trinkwasserverordnung §14 (Germany) E83 Belgaqua (Belgium) E84 AS/NZS 4020 (Australia/New Zealand) E85 GB/T 5750 (China) E86 General purpose / Without drinking water approval E89 Country of origin France E90 Communication HART with 4 … 20 mA output, active or passive F01 Modbus RTU / RS485 F04

PROFIBUS PA F05

PROFIBUS DP F06

PROFINET F07

EtherNet/IP F09

MODBUS TCP/IP F10

I/O extension Digital input / output, passive F30 Custody transfer approval Wtihout approval G00 MI-001 cold water meter G01 OIML R49 - Class 2 accuracy G05 OIML R49 - Class 1 accuracy G06 MI-001 - OIML R49 verification No initial verification, without certification, default factory calibration for DN 50 ... 300, 2 ... 12 inch

G10

Dynamic range Q3/Q1 = 40 DN 50 … 300, 2 … 12 inch G11

SITRANS FM (electromagnetic)

3/39Siemens FI 01 · 2025

© Siemens AG 2025 https://www.pia-portal.automation.siemens.com/SIE/Z3_PIA_Portal/?sap-language=EN&P_MATNR=7ME653*

Selection and ordering data (continued)

Additional information Order code Dynamic range Q3/Q1 = 80 DN 50 … 300, 2 … 12 inch G13 Dynamic range Q3/Q1 = 160 DN 50 … 300, 1 … 12 inch G16 Dynamic range Q3/Q1 = 200 DN 50 … 300, 2 … 12 inch G17 Dynamic range Q3/Q1 = 400 DN 50 … 300, 2 … 12 inch G20 Device options Sensor terminal board factory mounted J00 Sensor cables factory mounted J01 Factory preconfigured for transmitter mounting in compact design (integral mount)

J02

Display with protection cover J03 Breathing vent M20 thread, IP67 J04 Breathing vent ½" NPT thread, IP67 J05 Industrial Micro-SD memory card, 20 GB storage capacity J06 Nameplate in Chinese language J20 Type of Ex protection Increased safety (Ex e) Zone 2 L12 Non-incendive (NI) Class I, Division 2 L15 Type of protection (IP) IP68 (NEMA 6P) protection class for sensor and transmitter, without potting (to 2 m depth, 10 days)

L50

IP68 (NEMA 6P) protection class for sensor in remote design, factory potted (to 10 m depth, continuously)

L51

Sensor cables Cable kit with coil and electrode cable, standard type (3 × 1.5 mm2), PVC jacket

• 5 m (16 ft) T00

• 10 m (33 ft) T01

• 20 m (65 ft) T03

• 30 m (98 ft) T05

• 40 m (131 ft) T06

• 50 m (164 ft) T07

• 60 m (197 ft) T08

• 100 m (328 ft) T11

• 150 m (492 ft) T14

• 200 m (656 ft) T16

• 500 m (1640 ft) T18

Cable kit with coil cable standard type (3 × 1.5 mm2) and electrode cable special type (3 × 0.25 mm2), PVC jacket

• 5 m (16 ft) T50

• 10 m (33 ft) T51

• 15 m (49 ft) T52

• 20 m (65 ft) T53

• 25 m (82 ft) T54

• 30 m (98 ft) T55

• 40 m (131 ft) T56

• 50 m (164 ft) T57

• 60 m (197 ft) T58

• 100 m (328 ft) T61

Additional information Order code

• 150 m (492 ft) T64

• 200 m (656 ft) T66

• 500 m (1640 ft) T68

Device settings Measuring range: Upper range value (Qmax), unit Y01 Current output damping Y02 Current output signal range (Default setting: 4 ... 20 mA NAMUR)

Y03

Low flow cut off Y04 Flow direction (Default setting: Positive) Y05 Empty pipe detection (Default setting: Off) Y06 Mains frequency (Default setting: 50 Hz) Y07 Operation language display (Default setting English)

Y24

Device address (PROFIBUS 0 … 125) Y25 Device identification Location designation (TAG), device parameter and stainless-steel plate for transmitter (max. 32 characters)

Y11

Measuring point description, device parameter and stainless-steel plate for transmitter (max. 32 characters)

Y12

Location designation (TAG), device parameter and adhesive label for transmitter (max. 32 characters)

Y13

Measuring point description, device parameter and adhesive label for transmitter (max. 32 characters)

Y14

Location designation (TAG), device parameter and stainless-steel plate (max. 32 characters)

Y15

Measuring point description, device parameter and stainless-steel plate (max. 32 characters)

Y16

Location designation (TAG), device parameter and adhesive label (max. 32 characters)

Y18

Measuring point description, device parameter and adhesive label (max. 32 characters)

Y19

Totalizer 1 settings Preset value Y30 Unit (Default setting: m3) Y31 Direction (Default setting: Forward counting) Y32 Failure mode (Default setting: Continue counting) Y33 Decimal places (Default setting: 2) Y34 Totalizer 2 settings Preset value Y35 Unit (Default setting: m3) Y36 Direction (Default setting: Backward counting) Y37 Failure mode (Default setting: Continue counting) Y38 Decimal places (Default setting: 2) Y39 Totalizer 3 settings Preset value Y40 Unit (Default setting: m3) Y41 Direction (Default setting: Forward / backward counting, net) Y42 Failure mode (Default setting: Continue counting) Y43 Decimal places (Default setting: 2) Y44 Pulse output settings Volume per pulse Y50 Pulse width Y51

Flow sensors SITRANS FM (electromagnetic)

3/40 Siemens FI 01 · 2025

Technical specifications

SITRANS FMS500 flowmeter sensor Product characteristic For demanding applications in the water & wastewater industry Measurement of Volume flow, flow velocity, electrical conductivity Nominal diameter Coned sensor (octagon liner): DN 15 ... 40 (½" ... 1½")

Coned sensor: DN 50 ... 300 (2” ... 12”) Full bore sensor: DN 350 ... 2000 (14” ... 80”)

Mode of operation Measuring principle Electromagnetic induction Medium conductivity Liquids with an electrical conductivity ≥ 5 μS/cm Excitation frequency (mains supply: 50 Hz / 60 Hz)

DN 15 ... 65 (½" ... 2½"): 12.5 Hz / 15 Hz DN 80 ... 150 (3” ... 6”): 6.25 Hz / 7.5 Hz DN 200 ... 300 (8” ... 12”): 3.125 Hz / 3.75 Hz DN 350 ... 2000 (14” ... 80”): 1.5625 Hz / 1.875 Hz

Performance characteristics Electrical conductivity Repeatability: Max. ±5 % of measured value 2)

Process connection Flanges 1)

• EN 1092-1 PN 6 (87 psi): Raised face DN 1400 … 2000 (54" … 80") PN 10 (145 psi) Flat face DN 200 ... 300 (8" ... 12") PN 10 (145 psi) Raised face DN 350 ... 2000 (14" ... 80") PN 16 (232 psi) Flat face DN 50 ... 300 (2" ... 12") PN 16 (232 psi) Raised face DN 350 ... 1200 (14" ... 48") PN 40 (580 psi) Flat face DN 15 ... 40 (½" ... 1½")

• ANSI B16.5 Class 150 Flat face ½" ... 12” Class 150 Raised face 14" ... 24”

• AWWA C-207 Class D Flat face 28 ... 80"

• AS/NZS 4087 PN 16 (232 psi) Flat face DN 50 ... 300 (2" ... 12") PN 16 (232 psi) Raised face DN 350 ... 1200 (14" ... 48")

• JIS B 2220:2004 10K DN 15 ... 600 (1" ... 24")

Rated operating conditions Ambient temperature

• Sensor -20 ... +70 °C (-4 ... +158 °F)

• Compact with transmitter -20 ... +65 °C (-4 ... +149 °F)

Operating pressure (abs) (maximum operating pressure depending on flange type)

DN 15 ... 40 (1/2" ... 1 1/2"): 0.01 ... 40 bar (0.15 ... 580 psi) DN 50 ... 300 (2" ... 12"): 0.03 ... 20 bar (0.44 ... 290 psi) DN 350 ... 1200 (14" ... 48"): 0.01 ... 16 bar (0.15 ... 232 psi) DN 1400 … 2000 (54" … 80"): 0.01 … 10 bar (0.15 … 145 psi)

Protection class

• Standard IP66/67, NEMA 4X/6

• Optional IP68 and NEMA 6P (2 m, 10 days) for sensor in compact (integral mount) and remote design IP68 and NEMA 6P (10 m, continuously) for sensor in remote design

Mechanical load (vibration)

• Integral mount / compact version Vibration, sinusoidal according to IEC 60068-2-6

• 2 ... 4 Hz, 3.5 mm peak

• 8.4 ... 500 Hz, 1 g peak Vibration broad-band random, according to IEC 60068-2-64

• 10 ... 200 Hz, 0.003 g2/Hz

• 200 ... 500 Hz, 0.001 g2/Hz

• Total: 1.54 g rms

Vibration, sinusoidal according to IEC 60068-2-6• Remote version Sensor

• 2 ... 8.4 Hz, 7.5 mm peak

• 8.4 ... 500 Hz, 2 g peak

Transmitter

• 2 ... 8.4 Hz, 1.5 mm peak

• 8.4 ... 500 Hz, 0.7 g peak

SITRANS FM (electromagnetic)

3/41Siemens FI 01 · 2025

Technical specifications (continued)

SITRANS FMS500 flowmeter sensor Vibration broad-band random, according to IEC 60068-2 64• Remote version Sensor

• 10 ... 200 Hz, 0.01 g2/Hz

• 200 ... 500 Hz, 0.003 g2/Hz

• Total: 1.54 g rms

Transmitter

• 10 ... 200 Hz, 0.003 g2/Hz

• 200 ... 500 Hz, 0.001 g2/Hz

• Total: 1.54 g rms

Process temperature

• NBR liner -10 ... +70 °C (14 ... 158 °F)

• EPDM liner -10 ... +70 °C (14 ... 158 °F)

Pressure drop DN 15 and 25 (½" and 1"): Max. 20 mbar (0.29 psi) at 1 m/s (3 ft/s) DN 40 ... 300 (1½" ... 12"): Max. 25 mbar (0.36 psi) at 3 m/s (10 ft/s) DN 350 ... 2000 (14" ... 80"): Insignificant

Test pressure 1.5 × PN (where applicable) Design Dimensions See dimensional drawings Weight See dimensional drawings Material

• Housing and flanges Carbon steel ASTM A 105 with corrosion resistant coating of Class C4 or C5 (durability up to 15 years)

EN ISO 12944

• Measuring electrode Hastelloy C276 / 2.4819

• Grounding electrode Hastelloy C276 / 2.4819

• Measuring tube 2) Stainless steel AISI 304 / 1.4301

• Terminal box Polycarbonate

Cable entries 4 × metric thread (size M20 × 1.5) Calibration Standard Zero-point, 2 × 25 % and 2 × 90 % Optional • 5-point calibration: 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax

• 10-point calibration: ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax

• Matched pair calibration: default, 5-point or 10-point

• ISO/IEC 17025 accredited, 5-point, matched-pair calibration

Certificates and approvals General purpose CE (LVD, PED, EMC, RoHS), UKCA Drinking water • WRAS (WRc, BS 6920 material approval for cold water, GB)

• NSF/ANSI Standard 61 (Cold water, US)

• ACS listed (France)

• Compliance to Trinkwasserverordnung §14 (Germany)

• Belgaqua (Belgium)

• AS/NZS 4020 (Australia/New Zealand)

• GB/T 5750 (China)

Custody transfer • MI-001 cold water (EU): DN 50 ... 300 (2 ... 12 inch)

Explosion protection • FM - Non-incendive (NI) Class I, Division 2 4)

• ATEX / IECEx - Increased safety (Ex e) Zone 2 4)

Others • Environmental Product Declaration (EPD)

• MCERTS (GB environmental)

• EAC (Kazakhstan)

1) DN 750, DN 1050 and DN 1100 (30", 42" and 44") not available with EN 1092-1 (PN 10 and PN 16) and AS 4087 flanges

2) The value applies for measurement between 15 μS/cm and 5000 μS/cm at a reference temperature of 25 °C (77 °F)

3) DN > 300 (12”)

4) The Ex variant is only available with IP64 protection and in remote mounting

FMS500 (7ME653) with FMT020 (7ME694) The FM520 water meter, which combines the FMS500 sensor and FMT020 transmitter, is EU-type approved according to MID Directive

2014/32/EU of the European Parliament and of the Council of 26 February 2014 on Measuring Instruments (Annex III – Water Meters

Flow sensors SITRANS FM (electromagnetic)

3/42 Siemens FI 01 · 2025

Technical specifications (continued)

MI-001). It also meets OIML R49 recommendations for Class 1 and 2 (Water meters for cold potable water and hot water).

Extensive testing has ensured its superior measurement accuracy, even under challenging inlet and outlet conditions. This allows for flexible installation in tight spaces without the need for pipe re-rout ing, as the FMS500 functions as a 0D/0D device for both Class 1 and Class 2 accuracy, requiring no inlet or outlet sections.

Furthermore, while primarily a cold water meter, the FM520 has been rigorously tested and passed at temperatures up to 50 °C (122 °F), including 30 °C (86 °F). This robust performance means it can be used for custody transfer (CT) purposes up to 50 °C (122 °F).

Verification tolerances

MI-001 / OIML R49 Class 2 = 2%

OIML R49 Class 1 = 1%

MI-001 / OIML R49 Class 2 = 5%

OIML R49 Class 1 = 3%

±E%

Q4Q3Q2Q1

G00 - Without custody transfer approval Order code: G10 Size DN 50 (2") DN 65 (2½") DN 80 (3") DN 100 (4") DN 125 (5") DN 150 (6") DN 200 (8") DN 250 (10") DN 300 (12") UxDx 0 x DN Orientation All orientations Q3 [m³/h] 63 100 160 250 400 630 1000 1600 1600

G01 - MI-001

G05 - OIML R49 Class 2 G06 - OIML R49 Class 1 Order code: G11 Size DN 50 (2") DN 65 (2½") DN 80 (3") DN 100 (4") DN 125 (5") DN 150 (6") DN 200 (8") DN 250 (10") DN 300 (12") UxDx 0 x DN Orientation All orientations "R" Q3/Q1 40 40 40 40 40 40 40 40 40 Q4 [m³/h] 78.75 125 200 312.5 500 787.5 1250 2000 2000 Q3 [m³/h] 63 100 160 250 400 630 1000 1600 1600 Q2 [m³/h] 2.52 4 6.40 10 16 25.20 40 64 64 Q1 [m³/h] 1.58 2.50 4 6.25 10 15.75 25 40 40

G01 - MI-001

G05 - OIML R49 Class 2 G06 - OIML R49 Class 1 Order code: G13 Size DN 50 (2") DN 65 (2½") DN 80 (3") DN 100 (4") DN 125 (5") DN 150 (6") DN 200 (8") DN 250 (10") DN 300 (12") UxDx 0 x DN Orientation All orientations "R" Q3/Q1 80 80 80 80 80 80 80 80 80 Q4 [m³/h] 78.75 125 200 312.50 500 787.50 1250 2000 2000 Q3 [m³/h] 63 100 160 250 400 630 1000 1600 1600 Q2 [m³/h] 1.26 2 3.20 5 8 12.60 20 32 32 Q1 [m³/h] 0.79 1.25 2 3.13 5 7.88 12.50 20 20

SITRANS FM (electromagnetic)

3/43Siemens FI 01 · 2025

Technical specifications (continued)

G01 - MI-001

G05 - OIML R49 Class 2 Order code: G16 Size DN 50 (2") DN 65 (2½") DN 80 (3") DN 100 (4") DN 125 (5") DN 150 (6") DN 200 (8") DN 250 (10") DN 300 (12") UxDx 0 x DN Orientation All orientations "R" Q3/Q1 160 160 160 160 160 160 160 160 160 Q4 [m³/h] 78.75 125 200 312.5 500 787.5 1250 2000 2000 Q3 [m³/h] 63 100 160 250 400 630 1000 1600 1600 Q2 [m³/h] 0.63 1 1.60 2.50 4 6.3 10 16 16 Q1 [m³/h] 0.39 0.63 1 1.56 2.5 3.94 6.25 10 10

G01 - MI-001

G05 - OIML R49 Class 2 G06 - OIML R49 Class 1 Order code: G17 Size DN 50 (2") DN 65 (2½") DN 80 (3") DN 100 (4") DN 125 (5") DN 150 (6") DN 200 (8") DN 250 (10") DN 300 (12") UxDx 0 x DN Orientation All orientations "R" Q3/Q1 200 200 200 200 200 200 200 200 200 Q4 [m³/h] 78.75 125 200 312.5 500 787.5 1250 2000 2000 Q3 [m³/h] 63 100 160 250 400 630 1000 1600 1600 Q2 [m³/h] 0.5 0.8 1.28 2 3.2 5.04 8.00 12.8 12.8 Q1 [m³/h] 0.32 0.5 0.8 1.25 2 3.15 5.00 8 8

G01 - MI-001

G05 - OIML R49 Class 2 G06 - OIML R49 Class 1 Order code: G20 Size DN 50 (2") DN 65 (2½") DN 80 (3") DN 100 (4") DN 125 (5") DN 150 (6") DN 200 (8") DN 250 (10") DN 300 (12") UxDx 0 x DN Orientation All orientations "R" Q3/Q1 400 400 400 400 400 400 400 400 400 Q4 [m³/h] 78.75 125 200 312.5 500 787.5 1250 2000 2000 Q3 [m³/h] 63 100 160 250 400 630 1000 1600 1600 Q2 [m³/h] 0.25 0.4 0.64 1 1.6 2.52 4 6.4 6.4 Q1 [m³/h] 0.16 0.25 0.4 0.63 1 1.58 2.5 4 4

The following label is placed on the sensor terminal box and on the transmitter housing. An example of the product label is shown below:

Sensor label

XXX

Transmitter label

FM520 approvals are valid for:

Flow sensors SITRANS FM (electromagnetic)

3/44 Siemens FI 01 · 2025

Technical specifications (continued)

Sizes DN 50 ... 300 (2" ... 12") Performance range • R400 Class 2

• R200 Class 1

Installation • All orientation

• Compact or remote with max. 500 m cable

• Approved for forward metering but also designed to be used in reverse

Sensitivity class U0D0 (The meter requires 0xD straight pipe upstream and 0xD straight pipe downstream from the sensor)

Temperature class • T30 (0.1 ... 30 °C)

• T50 (0.1 ... 50 °C)

Pressure MAWP 16 (Maximum Allowable Working Pressure) Electromagnetic class E2 Mechanical class M1, Class B and O (building and outdoors) Climatic class -20 ... 55 °C (-4 ... 131 °F) Power supply • 12 ... 42 V DC, 12 W

• 100 ... 240 V AC, 50 ... 60 Hz, 25 VA

Software Designed according to WELMEC 7.2

Communication modules 1)

HART, PROFINET, MODBUS and ETHERNET IP have been certified and can only be used where national regulations permit it. The reading of ancillary devices may be used for testing and verification and for remote reading of the water meter.

1) Communication module need to be ordered together with the system (FM520), a retrofit of the communication module is not possible since it would break the CT seals.

Special MI-001 settings:

• Unit: m³

• Low flow cut-off: 0.9 mm/s

• Digital output: pulses

For other factory settings, see the operating instructions.

SITRANS FM (electromagnetic)

3/45Siemens FI 01 · 2025

Dimensional drawings

153.6 (6.05)

.1

A

L

D

153.6 (6.05)

.1

A

D

L

153.6 (6.05)

.1

A

D

L

SITRANS FMS500 Sensor: DN 15 … 40, ½" ... 1½" (left), DN 50 … 300, 2” … 12” (middle) and DN 350 … 2000, 14” … 80” (right)

Sensor SITRANS FMS500 (7ME653) Nominal diameter A D1 L 1) Weight 1)

[mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [kg] [lbs] 15 ½ 170 6.7 77 3.0 200 7.9 5 11 25 1 180 7.1 96 3.8 200 7.9 6 13 40 1½ 195 7.7 127 5.0 200 7.9 9 20 50 2 181 7.1 76 3.0 200 7.9 10 22 65 2½ 187 7.4 89 3.5 200 7.9 12 26 80 3 193 7.6 102 4.0 200 7.9 13 29 100 4 200 7.9 114 4.5 250 9.8 17 37 125 5 210 8.3 140 5.5 250 9.8 20 44 150 6 225 8.9 168 6.6 300 11.8 27 60 200 8 250 9.8 219 8.6 350 13.8 39 86 250 10 277 10.9 273 10.8 450 17.7 56 123 300 12 303 11.9 324 12.8 500 19.7 72 159 350 14 375 14.8 451 17.8 550 21.7 115 254 400 16 400 15.7 502 19.8 600 23.6 143 315 450 18 431 17.0 563 22.2 600 23.6 177 390 500 20 456 18.0 614 24.2 600 23.6 222 489 600 24 507 20.0 715 28.2 600 23.6 321 708 700 28 557 21.9 816 32.1 700 27.6 331 730 750 30 584 23.0 869 34.2 750 29.5 - - 800 32 609 24.0 927 36.5 800 31.5 386 851 900 36 656 25.8 1032 40.6 900 35.4 482 1063 1000 40 707 27.8 1136 44.7 1000 39.4 672 1482 1050 42 707 27.8 1136 44.7 1000 39.4 - - 1100 44 758 29.8 1238 48.7 1100 43.3 - - 1200 48 813 32.0 1348 53.1 1200 47.2 1116 2460 1400 54 918 36.1 1574 65.94 1400 55.1 1592 3502 1500 60 965 38.0 1672 65.83 1500 59.1 1850 4070 1600 66 1018 40.1 1774 75.39 1600 63.0 2110 4642 1800 72 1116 43.9 1974 77.72 1800 70.9 2560 5632 2000 80 1216 47.9 2174 85.59 2000 78.9 3640 8008

Flow sensors SITRANS FM (electromagnetic)

3/46 Siemens FI 01 · 2025

Dimensional drawings (continued)

1) Weights are appr. for sensor with EN 1092-1 PN 16 flanges without transmitter. With transmitter FMT020 mounted, weight is increased by appr. 1.0 kg

(2.2 lb).

SITRANS FM (electromagnetic)

3/47Siemens FI 01 · 2025

File details come from the government source that posted it. Updated .