The provided file is a comprehensive set of architectural and engineering drawings for the restoration of Building 1's envelope at the James A. Haley VA Hospital in Tampa, Florida. The documents include detailed plans spanning multiple floors, exterior elevations, mechanical and electrical specifications, and technical drawings covering window replacement, brick facade restoration, and structural modifications. The project involves a complete exterior renovation, including removing and replacing windows, brick veneer, precast concrete elements, and associated building systems, with careful attention to maintaining the building's functionality during construction.
The restoration project is valued between $5,000,000 and $10,000,000, with a solicitation issued on October 30, 2025, and proposals due on December 3, 2025, at 2:00 PM EST. A mandatory site visit is scheduled for November 12, 2025, at 10:00 AM EST, with interested contractors required to confirm attendance with Healthcare Engineer Nicole Dayton. The work will be performed at the James A. Haley VA Hospital, located at 13000 Bruce B. Downs Boulevard in Tampa, Florida, and involves comprehensive exterior envelope improvements while ensuring minimal disruption to the hospital's ongoing operations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24826R0011 0006-ko.pdf | ||
| 673-21-116-James Haley Restor B1_Addendum 03_02.23.26.pdf | ||
| 36C24826R0011 0005.pdf | ||
| VA NOTICE OF LIMITATIONS ON SUBCONTRACTING.pdf | ||
| 36C24826R0011 0004.pdf | ||
| 36C24826R0011 0003.pdf | ||
| 36C24826R0011 0002.pdf | ||
| WD-FL20260208 01-02-26.pdf | ||
| 673-21-116-James Haley Restor B1_Addendum 01_11.24.2025.pdf | ||
| SIGNING SHEET 1.pdf | ||
| 36C24826R0011 0001.pdf | ||
| SIGNING SHEET 2.pdf | ||
| 36C24826R0011_1.docx | DOCX document | |
| 36C24826R0011_1.docx | DOCX document | |
| 36C24826R0011_1.docx | DOCX document | |
| Experience information Sheet.pdf | ||
| EMR 1 page.pdf | ||
| PAST AND PRESENT PERFORMANCE QUESTIONNAIRE.docx | DOCX document | |
| 7 Tampa site map.pdf | ||
| WD FL20250208 05232025.pdf | ||
| Base Offer Price Breakdown - 1 page.xlsx | XLSX spreadsheet | |
| 7 100 CD3 Specs.pdf |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXTERIOR ELEVATION
INTERIOR ELEVATION
SECTION/DETAIL NUMBER
DRAWING NUMBER
COLUMN GRID
NOTE
WINDOW OPENING
DOOR OPENING
ROOM NAME
ROOM NUMBER
WALL TYPE
CEILING HEIGHT
10'-8"
X
X
XX.X-X
XX
X
1/A101
X
A101
X
A101
SIM
B ru c e
B D o w n s B lv d
E 131st Ave
Richard Silver Wy
E Fletcher Ave
E 132nd Ave
N n d S t
PROJECT SITE
S T A
T E
OF FLO
R
I D A
R E G
IS
TERED ARC
H
IT
E C T
J A S
ON
H. RO
S S
AR101907
VA Project No.
RDC/JPA Project No.
Department of Veterans Affairs Medical Center
PENNONI
ENGINEERING CONSULTANT
5755 RIO VISTS DRIVE
CLEARWATER, FL 33760
ARCHITECTURE PLANNING INTERIOR DESIGN
524 FERNWOOD AVENUE
ALTAMONTE SPRINGS, FLORIDA 32701
407.830.6522 P
RDC / JPA ARCHITECTURE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
BECS
STRUCTURAL ENGINEER
6339 TEN OAKS ROAD
SUITE 307
CLARKSVILLE, MD 21029-1155
ABOVE GROUP ENGINEERING
MECHANICAL ELECTRICAL CONSULTANT
305 EAST DR.,
SUITE H
MELBOURNE, FL 32904
/3
/2
:5
:2
P
M
RESTORATION OF BUILDING 1
ENVELOPE
01/31/25
COVER SHEET
G-001
RGDF
673-21-116
TAMPA, FLORIDA
B1
RESTORATION OF BUILDING 1 ENVELOPE
James A. Haley VA Hospital 13000 Bruce B Downs Blvd., Tampa, FL 33612 PROJECT #: 673-21-116
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS
22004.00
G-001 COVER SHEET
G-101 PHASING/FACADE PLAN
A-101 PIPE BASEMENT PLAN
A-102 GROUND FLOOR PLAN
A-103 FIRST FLOOR PLAN
A-104 SECOND FLOOR PLAN
A-105 THIRD FLOOR PLAN
A-106 FOURTH FLOOR PLAN
A-107 FIFTH FLOOR PLAN
A-108 SIXTH FLOOR PLAN
A-109 SEVENTH FLOOR PLAN
A-200 EXTERIOR ELEVATIONS - OVERVIEW
A-201 EXTERIOR ELEVATIONS - OVERVIEW
AD-202 O.R. DEMOLITION ELEVATIONS
A-203 EXT. ELEV. - EAST GRD. - 3RD FL.
A-204 EXT. ELEV. - SOUTH GRD. - 3RD FL.
A-205 EXT. ELEV. - WEST GRD. - 3RD FL.
A-206 EXT. ELEV. - NORTH GRD. - 3RD FL.
A-207 EXT. ELEV. - SOUTH 3RD - LWR. PENT.
A-208 EXT. ELEV. - NORTH 3RD - LWR. PENT.
A-220 WEST DUCT - ENL. ELEV.
A-221 WEST DUCT - WALL SECTIONS
A-310 DETAILS
A-311 DETAILS & WALL SECTIONS
A-601 NEW WINDOW TYPES
A-602 WALL TYPES & DETAILS
A-610 WINDOW DEMOLITION DETAILS
A-611 WINDOW DEMOLITION DETAILS
A-620 WINDOW NEW DETAILS
A-621 WINDOW NEW DETAILS
A-622 FIRST FLOOR REFLECTED CEILING PLAN & LEGEND
A-630 WINDOW SCHEDULE
A-701 INTERIOR WINDOW CONDITIONS
A-702 INTERIOR WINDOW CONDITIONS
S0.1 STRUCTRUAL GENERAL NOTES
S0.2 STRUCTRUAL SPECIFICATIONS
S0.3 STRUCTRUAL SPECIFICATIONS
S0.4 WIND LOADS
S1.1 DUCT TOWER FRAMING PLANS
S1.2 DUCT TOWER FRAMING PLANS
S2.1 EXTERIOR EXISTING ELEVATIONS - OVERVIEW
S2.2 EXTERIOR EXISTING ELEVATIONS - OVERVIEW
S2.3 EXT. ELV. - EAST GRD - 3RD FLR
S2.4 EXT. ELV. - EAST GRD - 3RD FLR
S2.5 EXT. ELV. - WEST GRD - 3RD FLR
S2.6 EXT. ELV. - NORTH GRD - 3RD FLR
S2.7 EXT. ELV. - EAST 3RD FLOOR - LWR. PENT.
S2.8 EXT. ELV. - SOUTH 3RD FLOOR - LWR. PENT.
S2.12 PHOTOS
S2.13 PHOTOS
S2.14 PHOTOS
S2.15 PHOTOS
S2.16 PHOTOS
S3.1 FRAMING SECTIONS
S3.2 FRAMING SECTIONS
S3.3 REPAIR DETAILS
S3.4 REPAIR DETAILS
S3.5 REPAIR DETAILS
S3.6 REPAIR DETAILS
M-001 MECHANICAL NOTES, LEGENDS, & SYMBOLS
M-201 MECHANICAL ELEVATIONS
M-202 MECHANICAL ELEVATIONS
E-001 ELECTRICAL LEGENDS & SYMBOLS
E-002 ELECTRICAL GENERAL NOTES
ED-101 ELECTRICAL EXTERIOR PLAN - DEMO
EP-101 ELECTRICAL EXTERIOR PLAN - NEW WORK
E-201 ELECTRICAL ELEVATIONS
E-202 ELECTRICAL ELEVATIONS
E-601 ELECTRICAL DIAGRAMS
DRAWING INDEX
GRAPHIC SYMBOLS
Scale: 12" = 1'-0"
Vicinity Map
524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523
2023 Florida Building Code, Building, Eighth Edition:
202 Definitions
• WIND-BORNE DEBRIS REGION. Areas within hurricane-prone regions located in areas where the ultimate design wind speed, Vult, is 140 mph (63.6 m/s) or greater.
1. For Risk Category IV buildings and other structures, the wind-borne debris region shall be based on Figure 1609.3(3).
1603.1.4 Wind design data.
The following information related to wind loads shall be shown, regardless of whether wind loads govern the design of the lateral force-resisting system of the structure:
1. Ultimate design wind speed, Vult, (3-second gust), miles per hour (km/hr), tornado speed, VT (mph) and nominal design wind speed, Vasd, (mph) as determined in accordance with Section 1609.3.1. Vult = 153 mph. See Structural Drawings
2. Risk category IV. See Structural Drawings
3. Effective plan area, Ae, for tornado design in accordance with Chapter 32 of ASCE 7.
4. Wind exposure Category = C. See Structural Drawings.
5. Applicable internal pressure coefficients and applicable tornado internal pressure coefficients.
6. Design wind pressures and their applicable zones with dimensions to be used for exterior component and cladding materials not specifically designed by the registered design professional responsible for the design of the structure, psf (kN/m2). Where design for tornado loads is required, the design pressures shown shall be the maximum of wind or tornado pressures.See Structural Drawings.
TABLE 1604.5
RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES IV - Buildings and other structures designated as essential facilities,
• Group I-2 occupancies having surgery or emergency treatment facilities.
1609.1.2 Protection of openings.
In wind-borne debris regions, glazed openings in buildings shall be impact resistant or protected with an impact-resistant covering meeting the requirements of ANSI/DASMA 115 (for garage doors and rolling doors) or TAS 201, 202 and 203, AAMA 506, ASTM E1996 and ASTM E1886 referenced herein, or an approved impact-resistant standard as follows:
1. Glazed openings located within 30 feet (9144 mm) of grade shall meet the requirements of the large missile test of ASTM E1996 (Level E missile rating).
2. Glazed openings located more than 30 feet (9144 mm) above grade shall meet the provisions of the small missile test of ASTM E1996. (Level D missile rating).
1609.1.2.1 Louvers.
Louvers protecting the exterior wall opening that are located within 30 feet (9144 mm) of grade shall meet the requirements of AMCA 540 or shall be protected by an impact-resistant cover complying with the large missile test of ASTM E1996 or an approved impact-resistance standard. Louvers required to be open for life safety purposes such as providing a breathable atmosphere shall meet the requirements of AMCA 540.
N
1609.3 Ultimate design wind speed.
• FIGURE 1609.3(3) ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES = >150 mph.
1. Area deignated as Wind-Borne Debris Region per 202.
1609.5 Tornado loads.
The design and construction of Risk Category III and IV buildings and other structures shall be in accordance with Chapter 32 of ASCE 7, except as modified by this code.
1609.6 Roof systems.
Roof systems shall be designed and constructed in accordance with Sections 1609.6.1 through 1609.6.3, as applicable.
1609.6.1 Roof deck.
The roof deck shall be designed to withstand the wind pressures determined in accordance with ASCE 7. Where design for tornado loads is required, the roof deck shall be designed to withstand the greater of wind pressures or tornado pressures determined in accordance with ASCE 7.
1609.6.2 Roof coverings.
Roof coverings shall comply with Section 1609.6.1.
1609.1.2.1 Louvers.
Louvers protecting the exterior wall opening that are located within 30 feet (9144 mm) of grade shall meet the requirements of AMCA 540 or shall be protected by an impact-resistant cover complying with the large missile test of ASTM E1996 or an approved impact-resistance standard. Louvers required to be open for life safety purposes such as providing a breathable atmosphere shall meet the requirements of AMCA 540.
1626.5.1 Louvers protecting the exterior wall envelope and are within 30 feet (9144 mm) of grade shall meet the requirements of AMCA 540 or TAS 201 (large missile test) or shall be protected by an impact-resistant cover complying with TAS 201 (large missile test), TAS 202 and TAS 203.
1626.5.2 Louvers required to be open for life safety purposes, such as providing a breathable atmosphere, that are protecting the exterior wall envelope and are within 30 feet (9144
mm) of grade shall meet the impact requirements of AMCA 540 or TAS 201 (large missile test).
1626.5.3 Open and closed louvers protecting the exterior wall envelope, regardless of their function or location from grade, shall also comply with uniform air pressure testing per TAS 202 protocol and either the cyclical wind pressure loading per TAS 203 protocol or by complying with both the impact and cyclical pressure testing of AMCA 540.
Revisions Date
100% BID DOCUMENTS 01/31/2025
UP
DN
DN
UP
UP
UP
T.O.S.= 71'-4 1/8"
T.O.S.= 87'-1 3/8"
687'-6 3/4"
T.O.S.= 57'-6 3/4"
T.O.S.= 59'-0 3/4"
T.O.S.= 85'-5 3/8"
1.03 2.18
T.O.S.= 147'-4 1/8"
T.O.S.= 88'-5 3/8"
T.O.S.= 146'-9 3/8"
T.O.S.= 83'-7 5/8"
2.42 2.42
T.O.S.= 147'-4 1/8"
T.O.S.= 71'-4 1/8"
T.O.S.= 83'-7 5/8" T.O.S.= 83'-7 5/8"
EE
M M
DDFF
G G
HH
II
KK
LL
JJ
VR
S
U
T
Q
P
O
N
M L
K
J
I
H
G
E C
C C
BB
AA
Z
Y
X
W
F
D
B
A
T.O.S.= 57'-6 3/4"
2.1012.101
2.101
2.101
2.101
2.105
1.03
2.1062.106
2.101
1.06
1.061.06
1.06
FACADE DESIGNATION (WITH WINDOWS)
PHASING LEGEND
X
S T
AT
E
OF FLOR
I D A
R
EGISTERED ARCH
IT
EC
T
J A
SO
N H. ROS
S
AR101907
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
1/
/2
:2 1:
A
M
RESTORATION OF BUILDING 1
ENVELOPE
01/31/25
PHASING/FACADE PLAN
G-101
RGDF
673-21-116
TAMPA, FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 22004.00
N Scale: 1" = 20'-0"1 PHASING & FACADE PLAN
524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523
NOTES:
1.03 Roof Deck - 7th floor below
1.06 Work scope at these facades are part of BID ITEM #2 (Deduct
Alternate).
2.18 Existing parapet wall.
2.42 Existing connector to Building 100, protect in place.
2.101 Hospital entrance.
2.105 Building 1 Dock / Loading Area. Maintain unobstructed access at all times. Coordinate adjacent construction staging with C.O.R.
2.106 Existing raised mechanical platform to remain.
GENERAL NOTES - ROOF
A. Exterior work can be divided into individual facades. Each façade includes masonry repair, window replacement, or both. Exterior abatement and/or repair work to a facade shall proceed any window replacement to that same facade.
B. To minimize risk levels during hurricane season in Southern Florida, exterior work shall be suspended during the calendar period between late July thru end of October. Exterior work not completed during this season shall resume in the following season.
C. Coordinate phase completion and start-up with the requirements set forth by the COR to maintain daily operations to near as normal as possible.
D. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours (11 am to 4 pm). Activities to occur during this time period include, but are not limited to saw cutting, jack hammering, hammer drilling, and core drilling.
E. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
F. Coordinate construction phasing for Building #1 with VA Medical Services directors, FMS Projects, and COR to establish schedule of temporary closures for interior construction access. Building #1 shall maintain continuous operation throughout construction.Displacement of occupants in patient care spaces to be avoided as much as possible. Availability of vacated spaces shall be coordinated and verified thru the C.O.R..
G. Note: Facade designations shown reference facades that include window replacement. Refer to exterior elevations for full scope of exterior work.
GENERAL NOTES - PHASING
A. The contractor shall provide and submit the Staging Plan for V.A.
review and approval before commencing work.
B. Roof elevations shown are approximate and are for general reference only.
C. Maintain unobstructed access from exterior means of egress doors and discharge routes. Maintain unobstructed access at paved parking areas and drive lanes for hospital patrons at all times.
Coordinate any temporary conflicts with C.O.R.
D. Coordinate crane access with C.O.R. Site shall be restored to original condition upon completion of work.
E. Contractor to protect all roof top units (RTU), ducts, and associated equipment during the project. All equipment to remain fully operable for the duration of project.
F. Prior to the start of masonry work, Contractor shall provide "pre-filter" protection of the outside air intakes of RTU's and intake building louvers adjacent to masonry work using MERV 8 air filter media rolls.
Replacement of internal RTU filters is not required as part of the project scope.
G. Contractor shall provide measures to ensure all dust and debris generated by the work remains within the work area and does not pose hazardous or objectionable conditions for employees, patients, public and building mechanical equipment.
H. The contractor shall provide temporary weather protection to prevent water entry into the building and to maintain the building in a weather-tight condition. Ensure that protection is in place and water-tight before the end of each day ’s work. During the work, the contractor shall be prepared for unexpected weather changes so that temporary protection can be quickly installed.
J. The Contractor shall protect the roof and associated systems.
Construction loads shall not exceed 25 PSF unless approved by the C.O.R. Damage caused by construction activity shall be repaired per the Owner’s direction at the Contractor's cost; all repairs must maintain existing warranties. All items must be secured and braced.
Install plywood cover board under all construction materials to protect existing roofing, parapet, and flashing. Do not store material, equipment, or demolition debris on the roof and other decks.
K. At all exterior work areas, the Contractor is to provide access to the design team and VAMC staff for observation of construction activities. Prior to the removal of exterior access equipment (swing stages, aerial platforms, etc.), provide the design team with (3) business days’ notice to allow for a site observation trip. If notice is not provided, the Contractor will be required to provide new access equipment for the site observation trip.
L. The Contractor is to secure all VA permits prior to execution of work.
20x20
H
H
MVD
MVD MVD
MVD
MVD
MVD
MVD
M
M
10128
.1
(E X
IS
TIN
G
E
LE
V
.6
AS-1
ET-1
HX-1
HX-2
PHW
P-1
SHW
P-1
FLOOR AHU
FUTURE GROUND
ACID
TANK
PRIMARY CABLES
PULLBOX FOR
36"x36"x8"
30" wide shelves ~26" apart
30" wide shelves ~26" apart w id e sh el ve s ap ar t
L dP H
L dP H
H dP
LL
dP H
UP
UP
S
TA
IR
UP
STAIR
#2
UP
UP
U P
DN
UP
UP
STAIR NO.
OPEN
RISER
UP
UP
UP
UP
UP
UP
U P
UP
U P
T
T T
T
T
TT
T
T
T
T
RETAINING
WALL
FCU-
MVD
MVD
C A R B O N
F
ILTE
R
S K
ID
M O U N
TE
D
R .O U N
IT
C
TR
L
P U M P
F D
R E
LO
C A
TE
D
E X
IS
TIN
G
TA
N K
AS-2
ET-1
AS-1
FCU-
FCU-
FCU-
UP
H
H
T
T
T
X
CLEARANCE & MINOR OBSTRUCTIONS - SEE SHEET 3/A-701
MAJOR OBSTRUCTIONS / EQUIPMENT - SEE SHEET 4/A-701
VENTS / DUCT WORK - SEE SHEET 1/A-701
WINDOW TREATMENTS - SEE SHEET 2/A-701
WALLS MAKING CONTACT WITH WINDOW - SEE SHEET 5/A-702
PATIENT LIFTS
ABOVE CEILING CONSTRUCTION REQUIRED - SEE SHEET 6/A-702
NOT IN CONTRACT / EXISTING TO REMAIN
FACADE DESIGNATION (WITH WINDOWS)
INTERIOR CONDITIONS LEGEND
S T
AT
E
OF FLOR
I D A
R
EGISTERED ARCH
IT
EC
T
J A
SO
N H. ROS
S
AR101907
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
1/
/2
:2 1:
A
M
RESTORATION OF BUILDING 1
ENVELOPE
01/31/25
PIPE BASEMENT PLAN
A-101
ACDF
673-21-116
TAMPA, FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 22004.00
N Scale: 1" = 20'-0"1 PIPE BASEMENT PLAN
524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523
NOTES:
A. These sheets contain colored linework and poche to illustrate existing conditions and facade designation. Drawings should be printed in color.
B. Verify existing conditions before ordering, fabrication, construction and installation of new work.
C. Coordinate access into each area of the building with the C.O.R.
before beginning demolition or installation of new work.
D. Remove and reinstall existing wood trim as required for the removal of existing windows and trim. Finish paint wood trim at head, jamb, and sill to match existing.
E. During the installation of windows, savage existing signage, window treatments, wall-mounted devices, etc., which are adjacent to the existing window opening. Once the window installation is complete, patch and repair the wall and reinstall items back to their original location.
F. Temporary doors location & sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. Confirm all locations with C.O.R.
GENERAL NOTES
DN
DNDN
UP
F-R
ATE-W
ALL-2FS-E (2 hour - Sm oke - existing) (C
O
LO
R 8)
F-R
ATE-W
ALL-2F-E (2 hour - existing) (C O
LO
R
8)
F-R
ATE-W
ALL-2FS (2 hour - Sm oke - new
) (C O
LO
R
53) F-R
ATE-W
ALL-2F (2 hour - new
) (C O
LO
R
13)
F-R
ATE-W
ALL-1F-E (1 hour - existing) (C O
LO
R
8)
F-R
ATE-W
ALL-SM
-E (Sm oke - existing) (C O
LO
R
8)
F-R
ATE-W
ALL-SM
(Sm oke - new ) (C
O
LO
R 73)
F-R
ATE-W
ALL-1F (1 hour - new ) (C
O
LO
R 5)
H
N
C
D
K M
A B
G
G
RTU
CORRIDOR
K E Y P
LA
N
N
G R O U N D
F
LO
O R
P H A S E
F E C
FEC
FEC
F E C
F E C
F E C
FEC
FEC
F E C
F E C
INTERC
OM
INTERC
OM
INTERCOMINTERCOM
D
C
23'-8"
'-1
3/
4"
'-4
14'-4"
'-8
/4
F
E
J
N
MED
GAS
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SH
EL
F U
N
IT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SHELF UNIT
SH
EL
F U
N
IT
SHELF UNIT
SHELF UNIT
SH
EL
F U
N
IT
RTU
CORRIDOR
MECHANICAL ----
TELEPHONE
SIGNAL
MECHANICAL
3T MRI
EQUIPMENT ROOM
CONTROL ROOM
OFFICE
CHIEF MRI
SECRETARY
STAFF PHYSICIAN
NON-PROF. NON-PHYS.
MAGNETIC TAPE
STAIR #21
MECHANICAL
LINENS
REPRODUCTION
MAIL ROOM
OFFICE PHARMACY
OFFICE PHARMACY
ELECTRICALOFFICE PHARMACY
OFFICES WAREHOUSE
WAREHOUSE STORAGE
C O R R
ID
O R
ST
A
IR
442 NSF 109 NSF
43 NSF
5 NSF
5 NSF
151 NSF
456 NSF
293 NSF
140 NSF
144 NSF
199 NSF
155 NSF
137 NSF
134 NSF
77 NSF
57 NSF
428 NSF
75 NSF
303 NSF
974 NSF
130 NSF
167 NSF
201 NSF180 NSF
280 NSF
1,398 NSF
N
SF
N
SF
GB-011 GB-010
GC-051
GC-052
GC-028b
GC-027
GC-028a
GC-028
GC-030
GC-031
GC-045
GC-046
GC-047
GC-049
S0-21-1
GC-050
GC-048
GC-008g
GC-008h
GC-008f
GC-008b GC-008dGC-008a
GC-008c
GC-004e
C 0-
S0
ELEVATOR
#18
WHEEL CHAIR RAMP
WHEEL CHAIR RAMP
D N
UP
DN
DN
@ 5%
SLOPE
S
LO
P E
SLOPE
@ 5%
AHU
A/C-13
G C
-049
G C
-008b
G B-011
G B-012
G B-013
G B-014
G C
-002
G D
-003s
G D
-003t
G D
-003e
G D
-004
G A-028
G D
-003d
G D
-001
G D
-002
G A-030
G A-020
G B-010
C 0-01-1
S0-3-1
C 0-06-1
C 0-07-1
C 0-01a-1
G B-020b
G A-017
G A-018
G A-006
G A-006a
WHEEL CHAIR RAMP
WHEEL CHAIR RAMP
EL S-4 EL S-5
ELEVATOR
EL S-10
SERVICE
EL S-11
ELEVATOR
SERVICE
ELEV
EL S-6
ELEC
. PAN
ELS
EL P-1 EL P-2
F E C
F G
H J
K L
M N
G
N .8
M .4
M .1
PH
AR
M
AC
Y
O
FFIC
E
PH
AR
M
AC
Y
M
EC
H
AN
IC
AL
R O
O M
H .A.C
TO
ILET
M
ALE
TO
ILET
FEM
ALE
ELEVATO
R
LO
BBY
FIR
E
C
LO
SET
SIG
N
AL
C
LO
SET
TELEPH
O
N E
C
LO
SET
H .A.C
LAU
N
D R
Y C
LO
SET
1,2 & 3
LO
BBY
ELEVATO
R 4 & 5
LO
BBY
ELEVATO
R
10 & 11
LO
BBY
H .A.C
C O
PIER
R
O O
M
H R
-LIN
KS
C O
R R
ID
O
R
STAIR
#3
C O
R R
ID
O
R
C O
R R
ID
O
R
C O
R R
ID
O
R
STO
R
AG
E
SELECTIVE
VERTICAL
SVC-1
PIPE/ELECT
CHASE
O
FFIC
E
PM
&R S
SEC
PM
&R S
O
FFIC
E C
H
IEF
PM
&R
S
EM
G
F-RATE-WALL-SM (Smoke - new) (COLOR 73)
F-RATE-WALL-SM-E (Smoke - existing) (COLOR 8)
F-RATE-WALL-1F-E (1 hour - existing) (COLOR 8) F-RATE-WALL-2F-E (2 hour - existing) (COLOR 8) F-RATE-WALL-2FS-E (2 hour - Smoke - existing) (COLOR 8)
F-RATE-WALL-1F (1 hour - new) (COLOR 5) F-RATE-WALL-2F (2 hour - new) (COLOR 13) F-RATE-WALL-2FS (2 hour - Smoke - new) (COLOR 53)
22 22
K-
KI
N G
ST
O
N C
_L
AV
AT
O
R Y
VI
TR
EO
U
S C
H
IN
A
K-4330
KIN
G
STO
N C
_TO
ILETS
VITR
EO
U S C
H
IN
A
K-4330 KINGSTON C_TOILETS VITREOUS CHINA
K-2006KINGSTONC_LAVATORYVITREOUS CHINA
K-2006 KINGSTON C_LAVATORY VITREOUS CHINA
K-4330 KINGSTON C_TOILETS VITREOUS CHINA
G .7
G .9
G F
E.7 E
D C
.2 C
B
A.1 A
J
G .7
G .9
H G
F E.7
E D
C .2
C B
A.1 A
20.1
G .7
G .9
G F
E.7 E
D C
.2 C
B
A.1 A
J
G .7
G .9
H G
F E.7
E D
C .2
C B
A.1 A
20.1
J.1
21.9
21.8
D O
W N
U P
D O
W N
U P
PY
XI
S
STL.
RAILING
STL.
RAILING
HANDRAIL
PASS-THRU
UNIT SUB
STA
A2A
A/C
A/C
P
LA
TF
O R M
P
LA
TF
O R M
PLATFORM
SCALE
MOTOR
GRILL
FRYER
OVEN
TOUNION
KETTLES
CONVECTION
OVEN
CONVECTION
CONVECTION
OVEN
CONVECTION
OVEN
BCS
SN
D O W N
STL.
RAILING
STL.
RAIL
UP
DOWN
DOWNTO
PIPE
BASEMENT
DOWN
DOWN UP
DOWN
UP
U P
U P
U P
D N
UP
STEPS
CONC.
DOWN
STEEL
RAIL
D N
UP
DN
DN
@ 5%
SLOPE
S
LO
P E
SLOPE
@ 5%
STAIRS
D O W N
U P
D N
UP
D N
UP
DN
@ 5%
S
LO
P E
SELECTIVE
VERTICAL
SVC-1
DUMBWAITERS
D W #1
D W #2
GVC-3
GVC-4
1 2 3
48"
1 2 3
RoomAB-6BAB-6CAB-6DBA-023ABA-023BC0-01A-1C0-05-1C0-05A-1C0-05B-1C0-05C-1C0-05D-1C0-08-1C0-09-1C0-XX-1GA-002GA-003GA-004GA-004AGA-004BGA-004BGA-004CGA-004DGA-005GA-005AGA-006GA-006AGA-007GA-008GA-009GA-009AGA-010GA-011GA-011AGA-011BGA-012GA-012AGA-013GA-013AGA-013AGA-014GA-015GA-016AGA-016BGA-016CGA-016DGA-017GA-018GA-021GA-022GA-023GA-023CGA-023DGA-024GA-024AGA-025GA-027GA-027AGA-027HGA-027IGA-027LGA-027MGA-027NGA-027OGA-027RGA-027SGA-027TGA-029GA-029AGA-029AGA-029BGA-029CGA-029DGA-029EGA-029JGA-029KGA-030GD-001GD-002GD-003CGD-003E?GD-003JGD-009S0-02-1S0-03-1
NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup
RoomAB-6BAB-6CAB-6DBA-023BBB-001BB-001ABB-001BC0-01-1C0-01B-1C0-01C-1C0-02-1C0-03-1C0-04-1C0-07-1GA-029DGB-010GB-011GB-013GB-014GB-015GB-017GB-020GB-020AGB-020BGB-020CGB-020DGB-021GB-021AGB-021EGB-022GB-022AGB-023BGB-024GB-024BGB-024CGB-024DGB-024FGB-025GB-025AGB-026GB-026AGB-026BGB-027GB-027AGB-027BGB-027CGB-027DGB-027FGB-029GB-030GB-030AGB-031GB-033GB-034GB-035GB-036GB-038GB-039GB-039AGC-002GC-003GD-003?GD-003EGD-003SGD-003TS0-03-1S0-04-1S0-05-1
NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup
RoomC0-01C-1C0-06-1C0-06A-1C0-07-1C0-07A-1C0-07B-1C0-18-1GB-010GB-011GC-001AGC-001BGC-002GC-003GC-004GC-004AGC-004BGC-004CGC-004DGC-004EGC-004GGC-004JGC-004KGC-005GC-006LGC-007GC-007AGC-007BGC-008GC-008AGC-008BGC-008CGC-008DGC-008FGC-008GGC-008HGC-008IGC-009GC-010GC-011GC-012GC-012AGC-020GC-021GC-022AGC-022BGC-023GC-025GC-026GC-026AGC-027GC-028GC-028AGC-028B
RoomGC-030GC-031GC-032GC-034GC-035GC-036GC-043GC-044GC-045GC-046GC-047GC-048GC-049GC-050GC-051GC-052GC-0XXGD-003?GD-003EGD-003SGD-003TGD-005GD-007GD-007GD-007DGD-007EGD-007FGD-007GGD-007NGD-007PGD-007QGD-007RS0-03-1S0-06-1S0-07-1S0-12-1S0-20-1S0-21-1S0-XX-1
NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup
RoomC0-01A-1C0-05D-1C0-06A-1C0-08-1C0-09-1C0-09A-1C0-10-1C0-11-1C0-12-1C0-13-1C0-14-1C0-15-1C0-16-1C0-17-1C0-21-1C0-XX-1GA-002GA-004GA-004BGA-004CGA-004DGA-017GA-029JGA-029KGA-030GB-037BGC-006GC-007VGC-007WGD-001GD-002GD-003E?GD-005GD-007GD-007GD-007AGD-007BGD-007CGD-007DGD-007EGD-007JGD-007MGD-007O
RoomGD-007PGD-007RGD-007SGD-007TGD-007UGD-008GD-009GD-010GD-010AGD-010BGD-010CGD-010DGD-011GD-012GD-012AGD-012BGD-012CGD-012DGD-012LGD-013GD-013AGD-013BGD-013CGD-014GD-014AGD-015GD-015AGD-015BGD-017GD-017AGD-017BGD-017CGD-017DGD-017EGD-017FGD-018GD-018AGD-020GD-020AGD-022GD-022AGD-023GD-023AGD-023B
RoomGD-023CGD-023DGD-023EGD-024GD-025GD-026GD-026AGD-027GD-029GD-030GD-031GD-031AGD-034GD-035GD-036GD-036AGD-036BGD-037GD-037AGD-037CGD-038GD-038AGD-038CGD-038DGD-038EGD-038FGD-038GGD-039GD-039AGD-039BGD-039CGD-040GD-0??GD-0XXS0-01-1S0-08-1S0-13-1S0-22-1
NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup
CC0-03
CC0-02
CC0-01
SOILED RECEIVING / DECON AREA
PATIENT
RECORD
GA-027
POOL
SERVICE
ROOM
GA-011a
CONSTRUCTION
LAYDOWN
GA-011
EMPLOYEE
GYM
GA-004b
MH TEAM
GROUP ROOM
GA-004b
MH ADMIN
(SWING)
GA-004c
GA-004c
GA-004d
CORRIDOR
CO-08-1
LOGISTICS
STORAGE
GD-010
SPS OFFICES
GD-012
GD-012d
WOMENS
LOCKERS
GD-013b
MENS
LOCKERS
GD-015a
ELECTRONICS
SHOP
GD-023a
SHOP
GD-023b
SHOP
GD-023c
BIOMED SHOP
GD-024
STERILE
STORAGE
GD-025
CART
STORAGE
GD-050
SOILED
RECEIVING/DECON
AREA
GD-051
H.A.C.
GD-047b
DECON
TOILET
GD-047a
MECH.
GD-047c
ELECTRICAL
GD-040
CORRIDOR
CO-21-1
ELECTRICAL342.19 SF
MEZZANINE
MECHANICAL
GD-036
CORRIDOR
CO-13-1
N&FS OFFICE
GD-007u
N&FS OFFICE
GD-007t
REFRIGERATOR
GD-007s
KITCHEN
ENTRY
GD-007v
DAIRY & EGG
GD-007g
PATIENT
LAUNDRY
GC-007
CORRIDOR
CO-07b-1
WAREHOUSE
GC-004
TRASH
COLLECTION
GC-012
GC-012a
WORKSTATIONS
GC-004h
STAIR #12
SO-12-1
STAIR #7
SO-07-1
WAREHOUSE
GC-004f
PHARMACY
STORAGE
GC-004k
STAIR #6
S0-06-1
EMS
SUPPLIES
GC-004e
GC-009
GC-010 GC-011
GB-024dGB-024c
OFFICE IMS
GB-024b OFFICE
GB-024f
OFFICE IMS
GB-024
STAIR #5
S0-05-1
COMPUTER
ROOM
S0-05-2
OFFICE STAFF
EMS
GB-030a
GB-029
STAIR #4
SO-04-1
UNION
OFFICE
GB-035
CORRIDOR
C0-01-1
LINEN ROOM
GB-036
N&FS
GB-031
N&FS
GB-033
CORRIDOR
CO-04-1
STORAGE
GB-038
MECHANICAL
BB-001a
TEMPORARY
STORAGE
AB-6d
AB-6c
ELECTRICAL
RELEASE OF
INFORMATION
GA-024
ELECTRICAL
GA-023d
DOCTORS
WORKROOM
GA-027s
DOCTORS
WORKROOM
GA-027r
GA-025
CORRIDOR
C0-05a-1
ELECTRICAL
GE-002
EMERGENCY
ELECTRICAL
GE-003
TELECOMMUNICATIONS
GE-004
SIGNAL
GE-005
MECHANICAL
GE-001
STORAGE
GA-027w
LOBBY
GA-027t
STAIR #9
S0-09-1
RR
GA-027h
RR
GA-027h
BARBER
SHOP
GD-036a
FOOD
PRODUCTION
OFFICE
GD007j
MAIN
KITCHEN
GD-007
GA-027a
GD-008
GD-0xx
W0-L2
Z
AA
AA0-02
1.04
1.05
C C
1.06
1.06
X
CLEARANCE & MINOR OBSTRUCTIONS - SEE SHEET 3/A-701
MAJOR OBSTRUCTIONS / EQUIPMENT - SEE SHEET 4/A-701
VENTS / DUCT WORK - SEE SHEET 1/A-701
WINDOW TREATMENTS - SEE SHEET 2/A-701
WALLS MAKING CONTACT WITH WINDOW - SEE SHEET 5/A-702
PATIENT LIFTS
ABOVE CEILING CONSTRUCTION REQUIRED - SEE SHEET 6/A-702
NOT IN CONTRACT / EXISTING TO REMAIN
FACADE DESIGNATION (WITH WINDOWS)
INTERIOR CONDITIONS LEGEND
S T
AT
E
OF FLOR
I D A
R
EGISTERED ARCH
IT
EC
T
J A
SO
N H. ROS
S
AR101907
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
1/
/2
:2 1:
A
M
RESTORATION OF BUILDING 1
ENVELOPE
01/31/25
GROUND FLOOR PLAN
A-102
RGDF
673-21-116
TAMPA, FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 22004.00
N Scale: 1" = 20'-0"1 GROUND FLOOR PLAN
524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523
NOTES:
1.04 Current VA project, this area is Not In Scope.
1.05 RTU Passage to Building 38
1.06 Work scope at these facades are part of BID ITEM #2 (Deduct
Alternate).
A. These sheets contain colored linework and poche to illustrate existing conditions and facade designation. Drawings should be printed in color.
B. Verify existing conditions before ordering, fabrication, construction and installation of new work.
C. Coordinate access into each area of the building with the C.O.R.
before beginning demolition or installation of new work.
D. Remove and reinstall existing wood trim as required for the removal of existing windows and trim. Finish paint wood trim at head, jamb, and sill to match existing.
E. During the installation of windows, savage existing signage, window treatments, wall-mounted devices, etc., which are adjacent to the existing window opening. Once the window installation is complete, patch and repair the wall and reinstall items back to their original location.
F. Temporary doors location & sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. Confirm all locations with C.O.R.
GENERAL NOTES
x x x x x x x x x x x x x x x x x x x x x x x x
B B m m ta bl e
10'-9"10'-8"8'-10"
11'-10" 12'-0" 12'-0" 7'-2" 7'-11" 7'-11" 11'-6"
5'-6"
A
F
D
H H
RAMP
R A M P
106 108
109 110
101 103
106 108
109 110
101 103
12'-2"22'-9"
13'-8"11'-8"
9'-0"11'-7" 9'-0"11'-7"
14'-0"8'-2" 14'-0"8'-2"
9'-4"11'-8"
5'-0"32'-1"
12'-6"9'-11" 11'-8"9'-11"
11'-8"9'-8"
4'-1"14'-2"
12'-2"22'-9"
13'-8"11'-8"
9'-0"11'-7" 9'-0"11'-7"
14'-0"8'-2" 14'-0"8'-2"
9'-4"11'-8"
5'-0"32'-1"
12'-6"9'-11" 11'-8"9'-11"
11'-8"9'-8"
4'-1"14'-2"
K-1728CHESAPEAKEC_LAVATORYVITREOUS
CHINA
A.P.
CORRIDOR
(CC-1)
STORAGE
CORRIDOR
CORRIDOR
TO
E X
TE
R
IO
R
E X
IT
EXISTING
EXISTING
EXISTING
EQUIP
ROOM
STORAGE
TOILET SPECIAL
PROCEDURES
STAFF
DRESS
CORRIDOR
SPECIAL
PROCEDURE
ROOM
MECHANICAL
ROOM
TOILET
STAIR
#20
NSF-33
NSF-94
NSF-49 NSF-376NSF-52
SF
NSF-545
NSF-76
NSF-55
1C-174B
1C-173
1C-177 1C-1821C-178
MRI-C-1
1C-174
1C-181
1C-183
S1-20-1
1 2 3 4
C
D
E
E.4
F
E.9
20.0000
73.0000 179.0000 5.0000 136.0000 8.0000
83.0000
272.0000
258.0000
304.0000
4'-8"
254.0000
306.0000
79.9702
182.0178
90.000042.0000
34.0000
118.0000
12.0001
77.9999 x;CART x;CART x;HORIZONTAL
LAMINAR
FLOW HOOD
x;HORIZONTAL
LAMINAR
FLOW HOOD
x;CART x;HORIZONTAL
LAMINAR
FLOW HOOD
x;BAKER
EDGEGUARD
x;BENCHTOP
BIOFLOW
CHAMBER
x;BENCHTOP
BIOFLOW
CHAMBER
FD
FD
FD
FD
FDFD
FD
FD
FD
FD
10"
13'-7"
E1
E2 E3
E4
E6 E7
E8
E9E1
E11
E12
E13
E14
E15
E16
E1
E18
E1
E20
E2
E22
E23
E24
E2
E25
E26
E27
E28
E29
E5
E17a
E17b
E1 a
E1 b
E2 5a
E2 8a
E3 E3a E3b
E3
E3c
8 10 11
16 18
19/20
112 117113 114115
119121
123 124
138139145
128 129
135 136 137
1 15315
40 New Equipment (Analyzer)
34 35
PrinterEasy Coder
Control StorageCentral Link
Track Compressor
Track UPS
Central Link Printer
IQ
IQ
IQ Pr in te rs
Un de rc ou nt er
Specimen Storage
IQ
Samples
Vo rte x M ixe r
M ad a Va c
Finnpipette Cole- Parm er
Shared Freezer
Label Printer
Pencil Sharpener
Printer
Printer
SpaPLUS
M icro-scope
Sam ple
Trays
Zentri-fugen
Nutator
At he na M ul ti-
Ly te
Beckman Coulter Immage 800
Rotator
UP
S
Magnify
Tosoh
Fluid Storage
Osmometer
Vortex Mixer
Sero-fuge
Lab Q uake
Im m ulite
Immulite
Is ot em p
Re f
FreezerRef (Used by COAG, Misc Testing, and Analyzer)
-8
Fr ee ze r
Ne w
Eq ui pm en t w/
C ar t (
AC
L
TO
P)
Easy Coder
3D Rotator
Under Counter Freezer
Laser Printer
Isotemp 202S
PFA 100's
KC1
Microscope
Diffcount
Digital Microscope & Computer Station
New Equipment w/ Cart (ACL
TOP 500 CTS)
Mini Vidas
Verify Now's & Printer
(Stores Reagents & Contrals for Analyzer)
Refrigerator w/ Sliding Doors
(CHEM)
Vacuette
Centrifuge
105 106107108109
Printer
(Stored Below) Central Link
UPS
Trituras 2
Trituras 1
Sample Handler
Re f
Sebia Electrophoresis
Sebia Hydrasys 2 Fluid Storage
Pippette Area
Printer
Sorvall Centrifuge
Printer
Freezer
Flowm eter
Fluid Storage Cart; goes w/ 160 & slides under counter
Printer
Isotemp Ref
Accuspin3 Centrifuge
Fluid Storage
VISTA
VISTA
At he na M ul ti-
Ly te
UP
S
WAM VISTA
Undercounter
ABBOTT ARCH
Decapper Fax
Laser Printer
Easy Coder
Specimen Receiving/Storage 2627 28
60 Cytospin
Speci- Mix
American Optical
EBA 12 Microscope
Blood Storage
Siemens Track
Siemens Utility Cabinet
Flowmeter has existing cart
Siemens DI Water System
108L.2 108H.2
A
A
CR
CR
C R
PP
EDP EDP
EDP EDP
EDP
ED
P
OVERHEAD
PARTITION
LINEN
CART
x;
NE
W
PA
SS
TH
RU
RE
F.
x;
PA
SS
TH
RU
x;
PA
SS
TH
RU
CCTV
CCTV
ICE
MED
CART
REFRIG
MICRO
PRINTER
PYXISPYXIS
LINEN CART
CODE CART
FAX
PNEU T
SYST
CODE CART
CODE CART
MED
CART
REFRIG
RECESSED
HANDICAP
DRINKING
FOUNTAIN
FOUNTAIN
DRINKING
PROCESSOR
F2
C A M E R A
B O X
B O X
C A M E R A
PACS
P
AC
S
DN
UP
UP
DN
D N U P
DN
UP
U P
D N
UP
DN
U P
D O W N
SVC/1
#2 W
D
#1 W
D 22
1 2 3
CABINET
W A
LL
C A B
IN
E T
E.9
D.8
F
E .4
E
D
C.4
C
.9 1 1.3 2 3 4
E
LE
V
C O R R
ID
O R
S
TO
R A G E
B1 -0
B1 -0
B1 -0
B1 -0
F1 -0
F1 -0
F1 -0
F1 -0
A1 -1
A1 -1
A1 -1
A1 -1
A1 -1
A1 -1
A1 -0
A1 -0
A1 -0
A1 -0
AA1-08
P1 -0
P1 -0
P1 -0
P1 -0
P1 -0
P1 -0
O1-06
O1-05
O1-04
O1-03
O1-02
O1-01
N 1-
N 1-
N 1-
N 1-
M1-10
M1-09
M1-08
M1-07
M1-06
M1-05
M1-04
M1-02 M1-01
L1 -0
L1 -0
L1 -0
L1 -0
L1 -0
L1 -0
L1 -0
K1-03
K1-02
K1-01
G1-02
G1-01
AA1-01
AA1-02
AA1-03
AA1-04
AA1-05
AA1-06
AA1-07
Z1 -0
Z1 -0
Z1 -0
Z1 -0
Z1 -0
Y1-01
Y1-02
Y1-03
Y1-04
Y1-05
Y1-06
X1 -0
X1
-0
X1 -0
X1 -0
X1 -0
X1 -0
W1-06
W1-05
W1-04
W1-03
W1-02
W1-01
V1 -0
V1 -0
V1 -0
V1 -0
V1 -0
V1 -0
U1-01
R 1-
R 1-
R 1-
R 1-
R 1-
R 1-
Q1-01
Q1-04
Q1-06
Z1 -0
N 1-
M1-03
N 1-
Q1-05
Q1-03
Q1-02
F1 -0
RR
J1 -0
J1 -0
H 1-
H 1-
H 1-
H 1-
H 1-
I1-01
I1-02
I1-04
I1-03
D 1-
D 1-
C1-01
EXAM
1A-150
RESTROOM
1A-150a EXAM
1A-151
EXAM
1A-152
EXAM
1A-154
EXAM
1A-156
Cast Room 1A-160
EXAM
1A-162
EXAM
1A-158
CONFERENCE
1A-171
EXAM
1A-169
EXAM
1A-173
INTERNAL
MEDICINE
CLINIC
WAITING
1A-176
EXAM
1A-173a
1B-102
CORRIDOR
C1-15-1
1B-102i
CLINIC/EDUCATION
1B-102j
CLINIC
EDUCATION/CONFERENCE
1B-109
OFFICE
1B-111
RESTROOM
1B-111aOFFICE
1B-112
OFFICE
1B-1141B-114a
OFFICE
1B-116
OFFICE
1B-118a
OFFICE
1B-118
OFFICE
1B-119a
OFFICE
1B-119
SLEEP LAB
1B-122a
SLEEP LAB
1B-122
STAIR #4
S1-04-1 OFFICE
1B-123a
OFFICE
1B-123
RESPIRATORY
THERAPY
BREAK ROOM
1B-124
OFFICE
SURGERY
1B-128
OFFICE
SURGERY
1B-127
FELLOWS
1B-136
DR OFFICE
1B-130
APRN
1B-138
INFUSION
TREATMENT
CHAIR AREA
1B-140
S1-05-1 1B-141
INFUSION
TREATMENT
CHAIR AREA
1B-143
CORRIDOR
C1-23-1
BREAK ROOM
1B-155
ATTENDING
EXAM ROOM
1B-154
ATTENDING
EXAM ROOM
1B-152
ATTENDING
EXAM ROOM
1B-150
1B-149a
ATTENDING
EXAM ROOM
1B-148
WAITING
1B-156
CORRIDOR
C1-49-1
1B-156dELECTRICAL 1B-156c
CONFERENCE
ROOM
1B-156g
1B-156a 1B-156b 1B-157 1B-159
C1-49-9CORRIDOR
1B-1581B-156e
LITHOTRIPTER
1B-104
NURSING
1C-102a
1C-102
MEDICAL
CONFERENCE
1C-104
STORAGE
1C-104a
1C-104d
1C-104a
1C-104b 1C-104c 1C-107d
ELECTRICAL WAITING
1C-107
A/C UNIT
PATIENT
RESTROOM
1C-108
EXAM
1C-109
EXAM
1C-111
1C-113 1C-112
EXAM
1C-115
EXAM
1C-116
EXAM
1C-122
EXAM
1C-122a
EXAM
1C-120
EXAM
1C-120a
EXAM
1C-118
EXAM
1C-118a
STAIR #6
S1-06-1
EXAM
1C-123a
EXAM
1C-123
EXAM
1C-125a
EXAM
1C-125
SUPERVISOR
OUTPATIENT
UNIT
1C-127a
RECORDS
PREP.
1C-127
1C-129
1C-133
EXAM
1C-135
EXAM
1C-136
EXAM
1C-136a
EXAM
1C-138
EXAM
1C-138A
EXAM
1C-140
EXAM
1C-140a
STAIR #7
S1-07-1
EXAM/CONFERENCE
1C-141
EXAM
1C-141a
EXAM
1C-143
EXAM/CAST
ROOM
1C-143a
EXAM
1C-145
EXAM
1C-145a
EXAM
1C-147
EXAM
1C-148
EXAM
1C-150
EXAM
1C-152SCREEN/EXAM
1C-154
RESTROOM
1C-156
1C-158a
WAITING
1C-158
SECRETARY
CLERK &
FILES
1C-170
OFFICE
ASSISTANT
1D-123
OFFICE CHIEF
1D-123
OFFICE
SECRETARY
1D-124
1D-125
1D-126
CONFERENCE
ROOM
1C-172
IV ROOM
1D-127a 1D-149a 1D-149b 1D-149c
1D-149d 1D-149f 1D-149g 1D-149h 1D-149i
1D-170
1D-171a
1D-171
1D-172a1D-172b1D-172c1D-172d
1D-172e
1D-173 1D-172
1D-174 1D-174a
1D-174b
1D-174c
1D-176
1D-176a
1D-179a
1D-177a
1D-179b
1D-179c
1D-177b
C1-xx-01
C1-xx-02
STARBUCKS
1D-1xx
VESTIBULE
V1-01-1
MECHANICAL
1D-101d
VESTIBULE
V1-02-1
MAIN LOBBY
1D-101Room
1D-102 Room
1D-103
ENROLLMENT
1A-103OFFICE
1A-104
OFFICE/EXAM
1A-104a
VESTIBULE
V1-03-1
INTERNAL
MEDICINE
1A-106y
ALPHA CHECK
IN
1A-106w
WAITING
1A-106t
EXAM
1A-106u
64 SLICE
1A-125
CONTROL
ROOM
1A-126
READING
ROOM
1A-127ADPAC
1A-130
EMERGENCY
ISOLATION
ROOM
1A-133
EMERGENCY
ISOLATION
ROOM
1A-134
OPERATIONS
ROOM
1A-147
1A-147b 1A-147a
1A-144
COMMUNICATIONS
1A-115
TRIAGE
1A-140
EMERGENCY
ROOM #3
1A-138
1A-1xx
MON EXAM
#13
1E-140
MON EXAM
#12 1E-139
MON EXAM
#11
1E-137
MON EXAM
#10 1E-135
MON EXAM #9
1E-133
PROCEDURE/CAST
1E-132
MON EXAM
1E-131
MON EXAM #7
1E-129
MON EXAM #6
1A-128
MON EXAM #5
1A-127
MON EXAM #4
1E-126
TRIAGE #3
1E-105
TRIAGE#2
1E-128
TRIAGE#1
1E-103
PRE-TRIAGE
1E-134MON
EXAM#14
1E-141
MON
EXAM#15
1E-142
WAITING
1E-101
V1-04-1
CONFERENCE
1D-194 PATH.
1D-194b
PATH.
1D-194a
PATH.
1D-194e
PATH.
1D-194f
PATH.
1D-194c
COMM.
1D-186
ELEC.
1D-187
PATH.
1D-194d
STAIR
S1-22-1
OFFICE
1D-195d
OFFICE
1D-195c
RR
1D-193
RR
1D-192
PATH.
1D-191
PATH.
1D-190
PATH.
1D-189
CORRIDOR
C1-22-1
CORRIDOR
C1-24-1
CORRIDOR
C1-47-1
CORRIDOR
C1-48-1
CORRIDOR
C1-20-1
CORRIDOR
C1-19a-1
CORRIDOR
C1-19-1
CORRIDOR
C1-18-1
CORRIDOR
C1-17-1 ELEVATOR
LOBBY
1C-101
CORRIDOR
C1-28-1
COORIDOR
C1-28-2
CORRIDOR
C1-30-1
CORRIDOR
C1-31-1
CORRIDOR
C1-32-1
CORRIDOR
C1-34-1
CORRIDOR
C1-38-1
CORRIDOR
C1-40-1
CORRIDOR
C1-50-1
CORRIDOR
C1-57-1
CORRIDOR
C1-55-1
CORR.
C1-59-01
CORRIDOR
C1-56-1
CORRIDOR
C1-54-1
1E-121 1E-122 1E-123MON EXAM
#1
1E-119
MON EXAM
#2
1E-120
VESTIBULE
V1-05-1
RADIOGRAPHY
1E-125
CONFERENCE
/ TRAINING
1E-108
NURSE
MANAGER
1E-109
RR
1E-110a
ON CALL
1E-110
BEREAVMENT
1E-115
HOLDING
ROOM #1
1E-116
STAFF
LOCKER /
BREAK ROOM
1E-117
J1 -0
J1 -0
J1 -0
AFB
MYCOLOGY
1D-196f
PROCESSING
ROOM
1D-196h
AMPLIFICATION
& DETECTION
1D-195i
SPECIMEN
PREP.
1D-195h
REAGENT
PREP
1D-195e
CC1-01
CC1-02
CC1-03
CC1-04
CC1-05
CC1-06
CC1-07
CC1-08
CC1-09
CC1-10
A1 -0
A1 -0
A1 -0
A1 -0
A1 -0
BB
1-
BB
1-
BB
1-
F1 -0
F1 -0
F1 -0
F1 -0
B1 -0
B1 -0
1-008
1-
1-
1-
1-004
1-003
1-011
VR
S
U
T
Q
P
O
N
M L
K
J
I
H
G
E C
C C
BB
AA
Z
Y
X
W
F D B
A
A-622
Sim
1.04
1.05
1.06 1.06
A-622
X
CLEARANCE & MINOR OBSTRUCTIONS - SEE SHEET 3/A-701
MAJOR OBSTRUCTIONS / EQUIPMENT - SEE SHEET 4/A-701
VENTS / DUCT WORK - SEE SHEET 1/A-701
WINDOW TREATMENTS - SEE SHEET 2/A-701
WALLS MAKING CONTACT WITH WINDOW - SEE SHEET 5/A-702
PATIENT LIFTS
ABOVE CEILING CONSTRUCTION REQUIRED - SEE SHEET 6/A-702
NOT IN CONTRACT / EXISTING TO REMAIN
FACADE DESIGNATION (WITH WINDOWS)
INTERIOR CONDITIONS LEGEND
S T
AT
E
OF FLOR
I D A
R
EGISTERED ARCH
IT
EC
T
J A
SO
N H. ROS
S
AR101907
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
1/
/2
:2 1:
A
M
RESTORATION OF BUILDING 1
ENVELOPE
01/31/25
FIRST FLOOR PLAN
A-103
RGDF
673-21-116
TAMPA, FLORIDA
B1
STATION CHIEF - MICHAEL ROGALA
100% BID DOCUMENTS 22004.00
N Scale: 1" = 20'-0"1 1st FLOOR PLAN
524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523
NOTES:
1.04 Current VA project, this area is Not In Scope.
1.05 RTU Passage to Building 38
1.06 Work scope at these facades are part of BID ITEM #2 (Deduct
Alternate).
A. These sheets contain colored linework and poche to illustrate existing conditions and facade designation. Drawings should be printed in color.
B. Verify existing conditions before ordering, fabrication, construction and installation of new work.
C. Coordinate access into each area of the building with the C.O.R.
before beginning demolition or installation of new work.
D. Remove and reinstall existing wood trim as required for the removal of existing windows and trim. Finish paint wood trim at head, jamb, and sill to match existing.
E. During the installation of windows, savage existing signage, window treatments, wall-mounted devices, etc., which are adjacent to the existing window opening. Once the window installation is complete, patch and repair the wall and reinstall items back to their original location.
F. Temporary doors location & sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. Confirm all locations with C.O.R.
GENERAL NOTES
HEAD
HEAD
HEAD
HEAD
HEAD
HEAD
15'-0"
CG1
CG1CG1
CG1CG1
CG1 CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1CG1
CG1
CG1
CG1 CG1
CG1 CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
BG1,2
BG1,2
BG1,2
BG1,2
BG1,2 BG1,2 BG1,2
BG1,2
BG1,2BG1,2
BG1,2
BG1,2
BG1,2
BG1,2BG1,2
BG1,2
BG1,2BG1,2
BG1,2 BG1,2
BG1,2
BG1,2BG1,2
BG1,2BG1,2BG1,2BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
BG1,2 BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
BG1,2 BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
CG1
CG1BG1,2
BG1,2
BG1,2
BG1,2
BG1,2
15'-0"
2-HOUR RATED PARTITION
(ALL SHOWN ARE EXISTING TO REMAIN)
CRP
CRP
J C
.2 H
G F
E D
C B
A
2019.61918.81817.917.11716.21614.9 151413121110 20.1 21 22
G .9
20.1 21 22
OFFICE
2D-225d
NEG.
PRESS.
ROOM 2
2D-225c
NEG.
PRESS.
ROOM 1
2D-225b
PACU
2D-225
NURSE STATION
POS.
PRESS.
ROOM 1
2D-225a
PACU
2D-225
TOILET
2D-225j
SOILED
UTILITY
2D-225g CLEAN
SUPPLY/MED
2D-225h
EQUIPMENT
STORAGE
2D-225e
NURSE STATION
m m A
RM
m m
AR
M m m
A R M m m
AR
M
1300mm ARM m m
AR
M m m
A R M
H E A D
1300m m
ARM
m m
A R M
1000m m
ARM
m m
AR
M m m
A R M
1300mm ARM m m
AR
M
H E A D
H E A D
1000m m
ARM
0mm
AR
M mm
AR
M
900m m ARM
1000mmARM
1300mm ARM
0m m
AR
M
900m m
AR
M mm AR M
900mmARM
1000mm
ARM
1000mm ARM
1000m m
ARM
1300mm ARM
H E A D
3 4 5
1 2
14151617
PPLT PPLT
PPLT PPLT
WEST
DUCT
SHAFT
POWER
COLUMN ANESTHESIA
STORAGE
MED ALCOVE
UP
DN
D O W N
SERVICE ELEVATORS
EL-S4 EL-S5
SVC-1
PASSENGER ELEVATORS
EL-P1 EL-P2 EL-P3
#2 W
D
#1 W
D
ROOM
DIVIDER
CANOPY ROOF
SUNSCREEN BELOW
SU
N
SC
RE
EN
B
EL
O W
EXISTING CONCRETE CANOPY
GUTTER:
WITH COLUMN
DOWNSPOUT INTEGRAL
CANOPY
SL
O
PE
D O W N 4"
FT
WALK PADS
RAMP
RAMP
LOCKER LOCKER
LOCKER LOCKER
TABLES
TABLES
BED BED
BEDBED
TV TV
TVTV
CHAIR CHAIR
CHAIRCHAIR
PPLT PPLT
PPLT PPLT
B.G.
CG
CG
CG
CG
CG
CG
CG
B.G.
FEC
FIRE EXTINGUISHER CABINET
DOOR SYMBOL - SEE 1-7
CUBICLE CURTAIN TRACKCCT
BG1,2
CG
BUMPER GUARDS 1 & 2
CORNER GUARD - 4 FT HIGH
WINDOW SYMBOL - SEE 1-7
WALL
LEGEND
EXISTING TO REMAIN
1-HOUR RATED PARTITION
TYP. PARTITION - 3 5/8" METAL
STUD W/ 5/8" GB EA SIDE
TYP. PARTITION - 3 5/8" METAL
STUD W/ 5/8" GB EA SIDE W/ SAB
FURRING PARTITION - 3 5/8" METALSTUD W/ 5/8" GB ONE
SIDE
PLUMBING CHASE
SEE SHEET 1-8 - PARTITION TYPES
FOR CONSTRUCTION DETAILS
1-HOUR RATED PARTITION
SHAFTWALL
1-HOUR RATED PARTITION
W/ SAB
TYP. PARTITION - 6" METAL
STUD W/ 5/8" GB EA SIDE W/ SAB
TYP. PARTITION - 6" METAL
STUD W/ 5/8" GB EA SIDE
FLOOR PLAN
NOTES:
1.
2.
3.
A.
B.
C.
D.
E.
4.
CONTRACTOR SHALL PATCH AND/OR REPAIR EXISTING WALLS
SCHEDULED TO REMAIN WHERE ABUTTED BY WALLS REMOVED
DURING DEMOLITION.
ALL MILLWORK IS TO BE PROVIDED BY MILCARE, INC., BY HERMAN
MILLER. MILLWORK IS DESCRIBED ON SHEETS 1-10 THROUGH
1-13. CONTRACTOR SHALL COORDINATE ALL WORK CONCERNING
FABRICATION, ASSEMBLY, DELIVERY AND INSTALLATION OF
MILLWORK. CONTRACTOR SHALL COORDINATE ELECTRICAL AND
PLUMBING WORK INSTALLED IN THE NEW MILLWORK.
PHASE I -
PHASE 1 IS LIMITED TO WORK IN MEN'S LOCKERS 203 & 203A.
PHASE 1 WORK IS TO BE COMPLETED BEFORE ANY WORK IS TO
BEGIN IN THE REST OF THE PROJECT. ALL WORK FOR PHASE
I SHALL BE SCHEDULED WITH THE COTR FOR EVENING, NIGHT &
WEEKEND HOURS.
ACCESS FROM CORRIDOR C2-1 TO MEN'S LOCKER 203A IS TO BE
MAINTAINED AT ALL TIMES DURING BUSINESS HOURS.
THIS PHASE IS CONSIDERED COMPLETE WHEN ALL SAFETY MEASURES
ARE IN PLACE IN CORRIDOR C2-1 AND ACCESS TO 203A IS PROVIDED
THROUGH THE NEW MEN'S LOCKER 203 WITH THE NEW PARTITIONS
DOORS AND FINISHES COMPLETE. INSTALLATION OF NEW LOCKERS
MAY BE DELAYED UNTIL ALL LOCKERS ARE TO BE INSTALLED.
PHASE 1 WORK INCLUDES (BUT IS NOT LIMITED TO):
NEW PARTITION BETWEEN 203 AND 217
NEW DOOR BETWEEN 203 AND C2-1
NEW OPENING BETWEEN 203 AND 203A
REMOVAL OF DOOR & FRAME BETWEEN 203A AND CORRIDOR
FILLING IN DOOR OPENING WITH GYP BOARD AND SAB
FINAL FINISHING OF WALLS IN 203 AND 203A
NEW FLOOR TILE, CEILING TILE, LIGHTS, HVAC, ETC., IN 203
CONSTRUCTION TUNNEL IN CORRIDOR C2-1
OTHER WORK AS REQUIRED BY THE COTR TO PROVIDE SAFE
AND CONTINUOUS ACCESS TO 203 VIA CORRIDOR C2-1
ALL WINDOW FRAMES AND SILLS ARE TO REMAIN INTACT AFTER DEMOLITION.
CONTRACTOR SHALL REPAIR OR REPLACES WINDOWS AND SILLS DAMAGED
DURING DEMOLITION.
FOR ALL LOCATIONS INDICATED AS WET AS SHOWN AT LEFT.
WATER RESISTANT GYPSUM WALLBOARD IS TO BE USED AS FINISH BOARD5.
UP
DN
UP
DN
DN
UP
U P
D N
DN
U P
D N
UP
UP
D O W N
DN
UP
SVC-1
#2 W
D
#1 W
D 22
1 2 3
GFI
GFI
V M A O
~ V
MA
O N
O M
AV
WAITING
"A"
PROCEDURE ROOM
UROLOGY SECRETARY
NURSES STATION/
STORAGE
NEW UROLOGY
PROCEDURE ROOM
RESIDENTS
DOCTOR
CONTROL/GENERATOR
TOILET
TOILET
CONTROL/GENERATOR
DOCTOR
RESIDENTS
PROCEDURE ROOM
NEW UROLOGY
STORAGE
NURSES STATION/
SECRETARYUROLOGY
PROCEDURE ROOM
"A"
WAITING
PROCEDURE ROOM
TOILET
NURSES STATION/
STORAGE
NEW UROLOGY
ELECT.
CLO.
ISOLATION ROOM
RECOVERY ROOM
RESIDENTS
SECRETARYWAITING
CONTROL ROOM
DOCTOR
PROCEDURE ROOM
UROLOGY
'A'
DOCTOR
CONTROL ROOM
WAITING
SECRETARY
RESIDENTS
RECOVERY ROOM
ISOLATION ROOM
CLO.
ELECT.
STORAGE
NURSES STATION/
TOILET
PROCEDURE ROOM
NEW UROLOGY
'A'
PROCEDURE ROOM
UROLOGY
EXTENSION
LEG
3'-6" 6'-6"
(VIEW
WINDOW)
STORAGE
WARMER
DESK
STORAGE
RACK
STORAGE
REFLECTED
ACCESS
PANEL
PANEL
ACCESS
REFLECTED
REFLECTEDACCESS
PANEL
STAGE
DINING EQUIPMENT
SCHEDULE
TOTAL NUMBER OF
SEATS
TRASH RECEPTACLE
(DOUBLE)
FOUR SEAT BOOTH, W/ 24"x44" TABLETHREE SEAT BOOTH, W/ 24"x24"
TABLEWHEELCHAIR
ACCESSIBLETWO SEAT BOOTH, W/ 24"x24"
TABLETRASH RECEPTACLE
(TRIPLE)D
E
C
NO.
A
B
ITEM
24"x47"
24"x47" 68"x24"
NO. OF
SEATSSIZE
68"x48"
68"x48"
QUANTITY
F PLANTER
G
42" WALL PANEL-NO GLASS
TOP
H 42" DIVIDER PANEL-w/18"ETCHED GLASS TOP GLASS TOP42" END PANEL-w/18"ETCHED GLASS TOP GLASS
TOPJ
Room2A-2012A-2022A-2032A-2052A-205A2A-205B2A-205C2A-205D2A-2062A-2072A-2082A-2092A-2102A-2112A-2132A-213A2A-213B2A-213C2A-213D2A-2142A-214A2A-2152A-215A2A-215A2A-215B2A-215C2A-215D2A-215E2A-215G2A-215J2A-215K2A-215L2A-215M2A-215M2A-215N2A-2162A-2172A-2182A-2192A-219A2A-2202A-2212A-2222A-2232A-2242A-224A2A-2252A-2282A-2292A-2302A-2312A-231A2A-231B2A-2322A-232A2A-232B2A-2332A-2342A-2352A-2362A-236A2A-236B2A-236C2A-236D2A-236E2A-236F2A-2372A-237A2A-2382A-238A2A-2392A-239A2A-239B2A-2402A-2412A-2422A-2432A-2442A-244A2A-244C2A-2452A-245A2A-2462A-246A2B-201E2B-202A2D-252L2D-252M2D-252N2D-252O
Room2D-252PC2-01-1C2-02-1C2-03-1C2-04-1C2-04A-1C2-05-1C2-06-1C2-07-1C2-08-1C2-09-1C2-10-1C2-11-1C2-44-1C2-49-1S2-02-1S2-09-1 NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup
Room2A-2152A-215?2A-215?2A-215A2A-215F2A-215M2B-201E2B-202A2B-2032B-203A2B-203B2B-2042B-2052B-205A2B-2072B-207A2B-207B2B-207C2B-2092B-2102B-2112B-2122B-2132B-2142B-2152B-215A2B-2162B-2172B-2182B-2192B-2202B-2212B-2222B-222A2B-2232B-2242B-224A2B-2252B-225A2B-2262B-226A2B-2272B-227A2B-227B2B-2282B-228A2B-2292B-2302B-230A2B-2312B-2322B-2332B-2342B-2352B-2362B-2372B-2382B-238A2B-238B2B-2392B-2402B-2412B-2422B-242B2B-2432B-244A2B-244B2B-2452B-245A2B-245B2B-2462B-246A2B-2472B-2482B-2492B-2502B-2512B-251A2B-251B2B-2532B-2542B-254C2B-2552B-255A2B-2562B-2572B-257B2B-257C2B-257D2B-2582C-2012C-204B?
Room?C2-11-1C2-12-1C2-13-1C2-13-1C2-14-1C2-15-1C2-15-1C2-17-1C2-17-1C2-18-1C2-19-1C2-19-1C2-21-1C2-21A-1S2-04-1S2-05-1SPACESPACE (21) NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup
Room2B-201E2C-2012C-201A2C-201B2C-201C2C-201D2C-2022C-202A2C-2032C-204A2C-204B2C-2052C-205A2C-205B2C-2062C-2072C-2082C-2092C-2102C-2112C-2122C-2132C-213A2C-213B2C-2142C-2152C-2162C-2182C-2192C-2202C-2222C-222A2C-222B2C-222C2C-222D2C-222E2C-223C2C-2242C-2252C-2262C-2272C-2282C-2292C-2302C-2312C-231A2C-2322C-2332C-2342C-2352C-2362C-2372C-2382C-2392C-2402C-2412C-2422C-242A2C-243A2C-2442C-244A2C-244B2C-2452C-2462C-247A2C-2482C-2492C-2502C-250A2C-250B2C-2512C-2522C-2532C-2542C-2552C-255A2C-255B2C-2562C-2572C-2582C-2592C-2602C-260A2C-2612C-2632C-2642C-2652C-2672C-267A2C-268A2C-2692C-2702C-2712C-271A2C-2722C-2732C-2742C-2752C-2762C-276B2C-276C2C-276C2C-276D2C-276E2D-2072D-2082D-2102D-2112D-213B2D-215C2-10-1C2-12-1C2-20-1
RoomC2-21-1C2-22-1C2-23-1C2-24-1C2-26-1C2-27-1C2-28-1C2-29-1C2-30-1C2-31-1C2-33-1C2-36-1S2-03-1S2-06-1S2-07-1 NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup
Room2A-2012A-2022A-2032A-2052A-205A2A-205B2A-205D2A-2062A-2072A-2082A-2092A-2102A-215D2A-215L2A-215M2A-215M2A-215N2A-2402A-2412A-2422A-2432A-2442A-244A2A-244C2A-2452A-245A2A-2462A-246A2B-201E2B-202A2C-201C2C-201D2C-2092C-2102C-2112C-2122C-2152C-2162C-2182C-2192C-2202C-2762C-276B2C-276C2D-2012D-2022D-2032D-2042D-2052D-2062D-2072D-2082D-209A2D-209B2D-209C2D-2102D-2112D-2122D-2132D-213A2D-213B2D-213C2D-2152D-2172D-217A2D-217B2D-2182D-218A2D-218B2D-218C2D-218D2D-218F2D-218G2D-218H2D-218J2D-218K2D-2192D-219A2D-219B2D-2202D-2212D-221A2D-221B2D-2252D-225A2D-225B2D-225C2D-225D2D-225E2D-225G2D-225H2D-225J
Room2D-2332D-2342D-2352D-2362D-2372D-237A2D-2382D-2392D-2402D-2412D-2412D-2432D-2452D-2452D-2462D-246B2D-246E2D-2472D-2482D-2492D-2502D-2512D-2522D-2522D-252A2D-252B2D-252C2D-252D2D-252E2D-252F2D-252G2D-252H2D-252I2D-252J2D-252K2D-252L2D-252M2D-252N2D-252O2D-252P2D-252Q2D-252R2D-252S2D-252T2D-252U2D-252V2D-252W2D-2532D-253A2D-255A2D-255B2D-255C2D-2562D-256A2D-256B2D-2572D-2582D-2592D-2602D-2652D-2662D-2672D-2682D-2692D-2702D-2712D-2722D-2732D-2742D-2752D-2762D-2772D-2782D-2792D-2802D-280A2D-2812D-2822D-2832D-2842D-2852D-2862D-2872D-2882D-2892D-2XXC2-01-1C2-10-1C2-31-1C2-32-1C2-32A-1C2-33-1
RoomC2-34-1C2-35-1C2-36-1C2-37-1C2-38-1C2-40-1C2-41-1C2-42-1C2-43-1C2-44-1C2-45-1C2-46-1C2-47-1C2-48-1C2-49-1C2-50-1C2-51-1C2-52-1C2-53-1S2-01-1S2-03-1S2-22-1SPACEV2-01-1V2-03-01V2-04-01 NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup NameServiceSupportsFTEE% Occup
B2 -0
B2 -0
B2 -0
B2 -0
B2 -0
B2 -0
B2 -0
B2 -0
F2 -0
F2 -0
F2 -0
F2 -0
A2 -1
A2 -1
A2 -0
A2 -0
A2 -0
A2 -0
A2 -1
A2 -1
A2 -1
A2 -1
AA2-08
P2 -0
P2 -0
P2 -0
P2 -0
P2 -0
P2 -0
O2-06
O2-05
O2-04
O2-03
O2-02
O2-01
N 2-
N 2-
N 2-
N 2-
M2-10
M2-09
M2-08
M2-07
M2-06
M2-05
M2-04
M2-02
M2-01L2 -0
L2 -0
L2 -0
L2 -0
L2 -0
L2 -0
L2 -0
K2-03
K2-02
K2-01
G2-02
G2-01
AA2-01
AA2-02
AA2-03
AA2-04
AA2-05
AA2-06
AA2-07
Z2 -0
Z2 -0
Z2 -0
Z2 -0
Z2 -0
Y2-01
Y2-02
Y2-03
Y2-04
Y2-05
X2 -0
X2 -0
X2 -0
X2 -0
X2 -0
X2 -0
W2-06W2-05
W2-04
W2-03
W2-02
W2-01
V2 -0
V2 -0
V2 -0
V2 -0
V2 -0
V2 -0
U2-06
R 2-
R 2-
R 2-
R 2-
R 2-
R 2-
Q2-01
Q2-02
Q2-03
Z2 -0
N 2-
M2-03
N 2-
U2-05
U2-04
U2-03
U2-02
U2-01
T2 -0
T2 -0
T2 -1
T2 -0
T2 -1
T2 -1
T2 -1
T2
-1
G2-05
G2-04
G2-03
F2 -0
CHANCEL
THERAPYELECTRICALPICC NURSES /
HOSPITALIST
C2-01
D 2-
02E2-01
BREAK RM
2B-209
OFFICE
2B-212
PI
2B-214
SPECIALIST
2B-216
AO
2B-218
RESIDENT
COOR.
2B-219
SECRETARY
TO CHIEF
2B-220
SURGICAL
SERVICE
CHIEF
2B-221
RESIDENTS
2B-222a
RESIDENTS
2B-222
ORTHO PA'S
(6)
2B-225
ORTHO
2B-226
ORTHO
2B-226a
GENERAL
DOC.
2B-228a
GENERAL
DOC.
2B-228
GENERAL
DOC.
2B-230a
GENERAL
DOC.
2B-230
OFFICE
2B-231
LOCKERS
2B-238a
BREAK ROOM
2B-238
STAIR #4
S2-04-1
RR
2B-238b
R.O. TANKS
2B-241
CLEAN
SUPPLY
2B-243
2B-245b 2B-215a
ISOLATION
2B-245
STAIRS
S2-05-1
MED'S
2B-249
PERITONEAL
2B-251
PERITONEAL
2B-251a
PATIENT RR
2B-254c
FAMILY
WAITING
2B-254
ELECTRICAL
2B-257
PATIENT
EDUCATION
2B-258
P.T. CLINIC
2C-204
PROSTHETICS
DISPENSARY
2C-204B
TRANSPORT
TEAM
2C-202
TRANSPORT
TEAM
2C-202a
OFFICE
2C-257b
OFFICE
2B-257c
OFFICE
2B-257d
2C-222a
BED
2C-275
BED
2C-273
RR
2C-271c
BED
2C-271
BED
2C-269
RR
2C-267a
BED RM.
2C-267
CONTROL
ROOM
2C-276d
PROCEDURE
ROOM
2C-276
CARDIAC
CATH. LAB #2
2C-277
UPS EQUIP
2D-215 ELECTRICAL
2D-213b
MAIN
COMPUTER
2C-276b
EQUIPMENT
2C-276c
BED RM.
2C-265 2C-264
4 BED ROOM
2C-263
2C-266
2C-260B2C-261
2C-260
STAIR #7
S2-07-14 BED ROOM
2C-258
4 BED ROOM
2C-256
4 BED ROOM
2C-254
CLASS RM.
2C-252
CLEAN
STORAGE
2C-251
OFFICE
2C-249
OFFICE
2C-247
OFFICE
2C-247a
OFFICE
2C-245
OFFICE
2C-243
OFFICE
2C-243b
OFFICE
2C-243a
OFFICE
2C-242
PAT ADMIN
2C-239
FLOW
CENTER
2C-238
CLEAN LINEN
2C-237
ADC/PAT
2C-236
ADC/PAT
SC-235
RR
2C-233
ADC/PAT
2C-232
ADC/PAT
2C-230
RR
2C-228
ADC/PAT
SC-227
ADC/PAT
SC-226
CONTROL RM.
2D-213c
CORRIDOR
C2-34-1
CORRIDOR
C2-38-1
CORRIDOR
C2-39-1
C2-39-2
OFFICE
2D-286
TOILET
2D-287
GAS
2D-284
SOIL
2D-283
H.A.C.
2D-282
C2-39-8
EQUIP.
2D-281
BREAK ROOM
2D-288
SOILED CART
2D-289
EQUIPMENT
STORAGE
2D-280
CORRIDOR
C2-51-1
CORRIDOR
C2-52-1
CORRIDOR
C2-53-1
ANESTHESIA
2D-265
COMM.
2D-266
2D-267
EQUIP.
2D-268
ELEC.
2D-269
FROZEN
SECTION
2D-270
STAIR #22
S2-22-1
SD-237a
2D-238
OPERATING
ROOM #4
2D-236
OPERATING
ROOM #5
2D-239
CORRIDOR
C2-41-1
STERILE
2D-237
STORAGE
2D-252PATIENT
ROOM #12
2D-252C
PATIENT
ROOM #11
2D-252D
PATIENT
ROOM #10
2D-252e
CORRIDOR
C2-43-1
CORRIDOR
C2-44-1
PATIENT
ROOM. #3
2D-252m
PATIENT
ROOM. #4
2D-252l
PATIENT
ROOM #5
2D-252k
PATIENT
ROOM #6
2D-252j
PATIENT
ROOM #7
2D-252i
PATIENT
ROOM #8
2D-252h
PATIENT
ROOM #9
2D-252f
HEAD NURSE
2D-252g
MULTI
PURPOSE
WORKROOM
2D-252nFREEZER
2A-205d
REF.
2A-205c
2A-205a 2A-205b
KITCHEN
2A-205
CORRIDOR
C2-04a-1
CANTEEN
DINING
2A-214
CONF. RM
2A-224a
STAIR #9
S2-09-1
SACRISTY
2A-224 CORRIDOR
C2-06-1
EUCH.
PRAYER
2A-228
AUDIOLOGY
2A-229
SECRETARY
2A-233
PATH.
2A-234
BREAK RM.
2A-235
STORAGE
2A-237a
PATIENT
LIBRARY
2A-237
WORK ROOM
& STORAGE
2A-238a
LIBRARY
OFFICE
2A-238
MEDICAL
LIBRARY
2A-239
REC. SERVICE
CHIEF
2A-215c
READING RM.
2A-239b
KITCHEN
2A-215b
CANTEEN
OFFICE
2A-243
CORR.
C2-08-1
VOLUNTARY
SERVICE
C2-08-2
VOLUNTARY
SERVICE
2A-215k
ELECTRICAL
2A-213
VOLUNTARY
SERVICE
2A-215e
CORR.
C2-09-1
CORR.
C2-02-1
FLEA MARKET
2A-211
ELEC.
2A-213a
AUDITORIUM
2A-215a
STORAGE
2A-215
STORAGE
2A-215
PROJECTION
BOOTH
2A-215f
CONFERENCE
2B-207
2B-207a
SURGERY
ADMIN
OFFICES
2B-207b
OFFICE
2B-205
2B-205a 2B-203a
2B-204
CORRIDOR
C2-12-1 ELEVATOR
LOBBY
2C-201
CORRIDOR
C2-21-1
CORRIDOR
C2-30-1
CORRIDOR
C2-28-1
CORRIDOR
C2-27-1
CORRIDOR
C2-26-1
CORRIDOR
C2-24-1
CORRIDOR
C2-23-1
CORRIDOR
C2-22-1
STAIR #6
S2-06-1
CORRIDOR
C2-20-1
CORRIDOR
C2-33-1
C2-40-1 C2-33-2
CORRIDOR
C2-05-1
CORRIDOR
C2-04-1
CORRIDOR
C2-03-1
CORRIDOR
C2-01-1
CORRIDOR
C2-13-1
CORRIDOR
C2-14-1
CORRIDOR
C2-15-1
CORRIDOR
C2-15-1
B2 -1
B2 -0
2B-247
2C-204A 2C-222 2C-222
F2 -0
F2 -0
F2 -0
F2…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .