7406712 DrawingsAsOne.pdf
PDF 38 MB Posted
- Attached to
- 7406712 Building 7019 Renovations
- Solicitation number
- N400857406712
About this file
This file contains architectural and structural drawings for Building 7019 Renovations at Marine Corps Air Station Cherry Point, North Carolina. The project entails a full renovation of an expeditionary barracks facility totaling approximately 10,983 square feet with 148 drawing sheets prepared by Naval Facilities Engineering Command Mid-Atlantic.
The drawings include life safety and code compliance plans indicating the building will be classified as R-2 (residential dormitory) under IBC 310.4, with Type II-B construction, a 1-story/21-foot height, and a 10,983-square-foot footprint. The facility will accommodate approximately 52 occupants across sleeping rooms with 8 persons per room, dining/training, kitchen, exercise, and common areas. The project incorporates a NFPA 13R wet pipe sprinkler system, emergency voice fire alarm and mass notification systems, and complies with 2024 IBC, UFC 1-200-01 (DOD Building Code), NFPA standards, and life safety requirements. Structural elements include concrete slab-on-grade with 4x4 W2.9x W2.9 welded wire reinforcing, new masonry partitions with #4 vertical reinforcement at 4-foot centers, light-gauge metal roof trusses at 4-foot centers maximum, and 1.5-inch 20-gauge Type B galvanized metal roof decking. Foundation design is based on 1500 PSF presumptive allowable soil bearing pressure with continuous and pad footings. The renovation includes new fire protection systems with a fire water tank, generator foundation, and mechanical/electrical/plumbing upgrades throughout the facility with various interior finishes, flooring materials, and equipment replacements specified across sleeping rooms, toilets, kitchen, and common areas.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 7406712 Amendment 0003.pdf | ||
| 7406712 Amendment 0002.pdf | ||
| 7406712 Amendment 0001.pdf | ||
| CJandA ML 25 03 Class FRCS Cherry Point - Redacted.pdf | ||
| 7406712 SpecsAsOne.pdf | ||
| Master PPI Form.xlsx | XLSX spreadsheet | |
| Gen MACC RFP_Feb2026_final.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING 7019
BUILDING 7019
OLF GATE
SEASHO
RE D
R
SHELL R
D
CORE SOUND
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
STATION CONSTRUTION WON:
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
STATION DESIGN WON:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
A R
IN
E
N A V A L S
T A T
IO
N
N O
R F O
L K V A
M A
R
IN
E C
O R
P S
A
IR
S T
A T
IO
N
C H
E R
R Y
P O
IN
T
N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
AS INDICATED
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERET
SI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
/1
/2
:4
:0
P M
C U s e rs
\s ig m o n \D o c u m e n ts
\2
A
R C
H s ig m o n
P
C R
M .r v t
T
IT
L E
S H
E E
T
G-001
7406712
12939426
REL REL DJE,III
L. PEED
H. PERRY
P. FAULKNER
D. CHASTAIN
7406712
01 JUL 2026
M C
O L
F A
T L A
N T
IC
B
U
IL
D
IN
G
R E
N O
V A
T
IO
N S
G -0
BUILDING 7019 RENOVATIONS
MCOLF ATLANTIC
MARINE CORPS AIR STATION CHERRY POINT
SCALE: NOT TO SCALE
D1
REGIONAL MAP N
SCALE: NOT TO SCALE
B1
VICINITY MAP N
SCALE: NOT TO SCALE
A1
BUILDING LOCATION MAP
SCALE: NOT TO SCALE
B3
MCOLF ATLANTIC INSTALLATION MAP
N
N
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
STATION CONSTRUTION WON:
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
STATION DESIGN WON:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
A R
V A L S
T A T
IO
N
N O
R F O
L K V A
M A
R
IN
E C
O R
P S
A
IR
S T
A T
IO
N
C H
E R
R Y
P O
IN
T
N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
AS INDICATED
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERET
SI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
/1
/2
:4
:0
P M
C U s e rs
\s ig m o n \D o c u m e n ts
\2
A
R C
H s ig m o n
P
C R
M .r v t
IN
D
E X
O F
D R
A W
IN
G
S
G-002
7406712
12939427
REL REL DJE,III
L. PEED
H. PERRY
P. FAULKNER
D. CHASTAIN
7406712
01 JUL 2026
M C
O L
F A
T L A
N T
IC
B
U
IL
D
IN
G
R E
N O
V A
T
IO
N S
G -0
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
X
Y
FIRE EXTINGUISHER CABINET (4-A:80-B:C)
FIRE EXTINGUISHER WALL BRACKET (AS INDICATED)
X = REQUIRED EGRESS CAPACITY (PERSONS)
Y = PROVIDED EGRESS CAPACITY (PERSONS)
NUMBER OF OCCUPANTS (PERSONS)
SMOKE BARRIER
1/2-HR FIRE BARRIER
1-HR FIRE BARRIER
ROOM TRAVEL DISTANCE
TRAVEL DISTANCE FROM ROOM
COMMON PATH OF TRAVEL
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
KNOX BOX
TD = XX-FT
CP = XX-FT
LIFE SAFETY LEGEND
xx
RT = XX-FT
K
FMCP
1. IBC INTERNATIONAL BUILDING CODE, 2024
2. UFC 1-200-01 DOD BUILDING CODE, CHANGE 4, 17 DECEMBER 2024
3. UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES,CHANGE 6, 6 MAY 2021
4. UFC 4-021-01 DESIGN AND O&M: MASS NOTIFICATION,CHANGE 1, 1 JANUARY 2010
5. FC 4-721-10N NAVY AND MARINE CORPS UNACCOMPANIED HOUSING, CHANGE 1, 24 APRIL 2025
6. NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS, 2025
7. NFPA 13R INSTALLATION OF SPRINKLER SYSTEMS IN LOW-RISE RESIDENTIAL OCCUPANCIES, 2025
8. NFP 20 INSTALLATION OF STATIONARY FIRE PUMPS FOR FIRE PROTECTION, 2025
9. NFPA 22 WATER TANKS FOR PRIVATE FIRE PROTECTION, 2023
10. NFPA 70 NATIONAL ELECTRICAL CODE, 2026
11. NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2025
12. NFPA 90A INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2024
13. NFPA 101 LIFE SAFETY CODE, 2024 (LSC)
BUILDING 7019
R-2 (IBC 310.4) / DORMITORY (LSC 6.1.8.1.4) - ORDINARY HAZARD (LSC 28.1.5.1)
BUILDING 7019
NFPA 13R WET PIPE SPRINKLER SYSTEM
EMERGENCY VOICE FIRE ALARM & MASS NOTIFICATION SYSTEM
BUILDING 7019 TYPE II-B
BUILDING 7019
BASED ON R-2 USE GROUP
ALLOWABLE FLOOR AREA (IBC TABLE 506.2): 16,000-SF
BASIC ALLOWABLE STORIES/HEIGHT (IBC TABLE 504.3 & 504.4): 4-STORIES/60-FT
BUILDING 7019
TOTAL FOOTPRINT FLOOR AREA 10,983-SF
TOTAL BUILDING HEIGHT 1-STORY/21-FT
(IBC TABLE 601) TYPE II-B
STRUCTURAL FRAME, INCL. COLUMNS, GIRDERS & TRUSSES 0-HR
BEARING WALLS, EXTERIOR 0-HR
BEARING WALLS, INTERIOR 0-HR
NON-BEARING WALLS, INTERIOR & EXTERIOR 0-HR
FLOOR CONSTRUCTION 0-HR
ROOF CONSTRUCTION 0-HR
EXTERIOR FIRE-RESISTANCE RATING BASED ON FIRE SEPARATION DISTANCE
THE DISTANCE BETWEEN BUILDINGS 7019 AND THE NEAREST ADJACENT BUILDING IS GREATER THAN 40-FT. THIS PROVIDES A FIRE SEPARATION DISTANCE FROM THE NEAREST ADJACENT BUILDING TO THE IMAGINARY PROPERTY LINE OF 30-FT AND A FIRE SEPARATION DISTANCE FROM BUILDING 7019 TO THE IMAGINARY PROPERTY OF AT LEAST 10-FT. THERE IS NO FIRE RESISTANCE RATING REQUIRED FOR THE EXTERIOR WALLS OF
BUILDING 7019 BASED ON THE FIRE SEPARATION DISTANCE.
AREA OCCUPANCY USE
APPROX.
AREA (SF)
OCCUPANT LOAD
FACTOR
(SF/PERSON)
OCCUPANT
LOAD
(PERSONS)
FIRST FLOOR
SLEEPING ROOMS 128-136
RESIDENTIAL - BUNK 270
8 PER ROOM 48
LIMITS (BASED ON DORMITORY OCCUPANCY WITH PERMITTED REDUCTION FOR SPRINKLERS):
EXITS (TABLE A.10.2.2) MINIMUM CLASS B
EXIT ACCESS CORRIDORS (TABLE A.10.2.2) MINIMUM CLASS C
OTHER SPACES (TABLE A.10.2.2) MINIMUM CLASS C
OCCUPANT LOADS (LSC TABLE 7.3.1.2)
SLEEPING ROOMS (BUNKS) 50-SF/PERSON OR 8 PERSONS PER ROOM
RESIDENTIAL 200-SF/PERSON
ASSEMBLY 15-SF/PERSON
EXERCISE ROOM WITH EQUIPMENT 50-SF/PERSON
KITCHEN 100-SF/PERSON
BUSINESS 150-SF/PERSON
MEP SPACE 500-SF/PERSON
STORAGE 500-SF/PERSON
COMMON PATH OF TRAVEL (LSC TABLE A.7.6): 50-FT
COMMON PATH OF TRAVEL - MECH ROOM (LSC 7.13.1(1)(a)) 100-FT
DEAD END CORRIDOR (LSC TABLE A.7.6): 50-FT
TRAVEL DISTANCE WITHIN ROOM (LSC TABLE A.7.6): 125-FT
TRAVEL DISTANCE FROM ROOM DOOR (LSC TABLE A.7.6): 200-FT
CAPACITY OF EXITS (LSC TABLE 7.3.3.1):
LEVEL COMPONENTS (WIDTH/PERSON) 0.2-IN/PERSON
STAIRWAYS (WIDTH/PERSON) 0.3-IN/PERSON
NUMBER OF EXITS (LSC 7.4)
2 EXITS FOR AREAS WITH AN OCCUPANT LOAD LESS THAN 500
1 EXIT FOR AREAS WITH THE EXIT ACCESS LESS THAN THE ALLOWABLE COMMON PATH OF TRAVEL (28.2.4.2)
MEANS OF EGRESS MUST BE ILLUMINATED IN ACCORDANCE WITH LSC 7.8 (LSC 28.2.8). ARTIFICIAL LIGHTING IS REQUIRED AT LOCATIONS AND TIMES NECESSARY TO MAINTAIN
ADEQUATE ILLUMINATION (LSC 7.8.1.2.1).
EMERGENCY LIGHTING SYSTEMS MUST PROVIDE IN ACCORDANCE WITH LSC 7.9.2.1 & 7.9.2.2 (LSC 28.2.8).
MEANS OF EGRESS MUST BE PROVIDED WITH SIGNS IN ACCORDANCE WITH LSC 7.10 AND UFC 3-600-01 10-2 (LSC 28.2.10). SIGNS MUST HAVE LETTERING ON AN OPAQUE BACKGROUND. INTERNALLY ILLUMINATED SIGNS MUST BE LIGHT EMITTING DIODE (LED) TYPE, ELECTROLUMINESCENCE (LEC), OR COLD CATHODE TYPE. INCANDESCENT FIXTURES ARE NOT PERMITTED (UFC 3-600-01 10-2.1.1). RADIOLUMINOUS EXIT SIGNS ARE NOT PERMITTED (UFC 3-600-01 10-2.2).
FIRE EXTINGUISHERS MUST BE PROVIDED THROUGHOUT THE BUILDING IN ACCORDANCE WITH NFPA 10.
SLEEPING ROOMS 122-127
10,983 203
FUEL-FIRED HEATER ROOMS 1-HOUR (LSC TABLE 28.3.2.2.2)
1-HOUR (LSC TABLE 28.3.2.2.2)
TOTAL
5 PER ROOM
FLOOR LEVEL
REQUIRED EXIT
CAPACITY
AVAILABLE EXIT
CAPACITY
NUMBER OF
EXITS REQUIRED
NUMBER OF
EXITS PROVIDED
FIRST FLOOR 721,700190
ROOM REQUIRED SEPARATION
RESIDENTIAL - BUNK
DINING/TRAINING 103 614 4115
KITCHEN 111 612 6100
ASSEMBLY
KITCHEN
LAUNDRY ROOMS > 100-SF
SLEEPING ROOM WALLS AND FLOORS 1/2-HOUR (LSC 28.3.7.2)
NO. OF
SLEEPING
ROOMS
APPLICABLE BUILDING CODES
USE GROUP/OCCUPANCY
FIRE PROTECTION SYSTEMS
CONSTRUCTION TYPE
ALLOWABLE AREA & HEIGHT
ACTUAL AREA & HEIGHT
FIRE RESISTANCE RATING FOR BUILDING ELEMENTS
EXTERIOR WALLS
INTERIOR FIRE RESISTANCE REQUIREMENTS
INTERIOR FINISH CLASSIFICATION
TRAVEL DISTANCES
CAPACITY OF EXITS
ADDITIONAL LIFE SAFETY CRITERIA
MEANS OF EGRESS
FIRE SEPARATION DISTANCE (FSD)
FSD < 10-FT
GROUP R-2 (TYPE II-B)
1-HR
FSD ≥ 10-FT 0-HR
1-HOUR (LSC TABLE 28.3.2.2.2)TRASH COLLECTION ROOMS
STORAGE ROOMS SMOKE PARTITION (LSC TABLE 28.3.2.2.2)
GYM 114 555 1150EXERCISE -
LOUNGE 116 457 3015ASSEMBLY -
DUTY/OFFICE ROOMS 331 2150BUSINESS -
MECH/ELEC/COMM/FIRE PUMP ROOMS 832 1500MEP -
REMAINING RESIDENTIAL AREAS 3,574 18200RESIDENTIAL -
STORAGE ROOMS 372 1500STORAGE -
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
STATION CONSTRUCTION WON:
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
STATION DESIGN WON:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
A R
V A L S
T A T
IO
N
N O
R F O
L K V A
M A
R
IN
E C
O R
P S
A
IR
S T
A T
IO
N
C H
E R
R Y
P O
IN
T
N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
AS INDICATED
Lic. No. 044409
AARON P FREIDC
O M M O
N W
EAL
THOF
V
IR
G
IN
IA
P R O F
E
SSIONAL EN
G
IN
E E R
1 JUL 2026
/1
/2
:3 :0
A
M
C U s e rs \a fr e id
\O n e D ri v e
J e n s e n H u g h e s \D o c u m e n ts
\2
F
IR
E a fr e id
.r v t
L
IF
E S
A F
E T
Y G
E N
E R
A L
N O
T E
S A
N D
L E
G E
N D
GI001
7406712
FINAL
12939428
TKL TKL APF
L. PEED
H. PERRY
P. FAULKNER
D. CHASTAIN
7406712
M C
O L
F A
T L A
N T
IC
B
U
IL
D
IN
G
R E
N O
V A
T
IO
N S
G I0
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
0 40' 80'
FMCP
FDC
RISER
IPL
FIRE
WATER
TANK
FDE
FP
CODE COMPLIANCE SITE PLAN
A3 SCALE: 1" = 40'-0"
NOTES:
FAL - FIRE ACCESS LANE (W - WIDTH)
FDC - FIRE DEPARTMENT CONNECTION
FDE - FIRE DEPARTMENT ENTRANCE
FP - FIRE PUMP
FMCP - FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
IPL - IMAGINARY PROPERTY LINE
RISER - SPRINKLER RISER
EGRESS DISCHARGE PATH
FAL W>20-FT
10'
10'
IPL
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
STATION CONSTRUCTION WON:
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
STATION DESIGN WON:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
A R
V A L S
T A T
IO
N
N O
R F O
L K V A
M A
R
IN
E C
O R
P S
A
IR
S T
A T
IO
N
C H
E R
R Y
P O
IN
T
N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
AS INDICATED
Lic. No. 044409
AARON P FREIDC
O M M O
N W
EAL
THOF
V
IR
G
IN
IA
P R O F
E
SSIONAL EN
G
IN
E E R
1 JUL 2026
/1
/2
:3 :1
A
M
C U s e rs \a fr e id
\O n e D ri v e
J e n s e n H u g h e s \D o c u m e n ts
\2
F
IR
E a fr e id
.r v t
C O
D E
C O
M P
L
IA
N C
E S
IT
E
P L
A N
GI002
7406712
FINAL
12939429
TKL TKL APF
L. PEED
H. PERRY
P. FAULKNER
D. CHASTAIN
7406712
M C
O L
F A
T L A
N T
IC
B
U
IL
D
IN
G
R E
N O
V A
T
IO
N S
G I0
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
K
F M
C P
WOMEN
LAUNDRY
ELEC.
106A COMM.
MECH.
FIRE PUMP
GYM STORAGE
114A
GYM
TRAINING STORAGE
KITCHEN
DINING/TRAINING
DRY STORAGE
TRASH
TOILET
111A
STORAGE
DUTY
OFFICE
CORRIDOR
LOBBY
LOUNGE
HEAD
120 BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
TOILET
128A
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BEDROOM
TOILET
135A
TOILET
136A
TOILET
134A
TOILET
133A
TOILET
132A
TOILET
131A
CORRIDOR
TOILET
130A
TOILET
129A
JAN
8 588888
55555555
REMAINING
RESIDENTIAL
RT = 30-FT
CP = 50-FT
CP = 47-FT
TD = 76-FT
KEY NOTES
1. FIRE EXTINGUISHER MUST BE CLASS K.
2. FIRE EXTINGUISHER MUST BE CLASS ABC (4-A:80-B:C).
3. PROVIDE KNOX BOX KEYED TO MATCH DOWNEAST FIRE
DEPARTMENT. COORDINATE LOCATION WITH DOWNEAST
FIRE DEPARTMENT FIRE CHIEF - WAYNE PITTMAN
(252-725-3579).
4. THIS IS AN UNPROTECTED OPENING IN ACCORDANCE WITH
LSC 28.3.6.2.
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
STATION CONSTRUCTION WON:
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
STATION DESIGN WON:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
A R
V A L S
T A T
IO
N
N O
R F O
L K V A
M A
R
IN
E C
O R
P S
A
IR
S T
A T
IO
N
C H
E R
R Y
P O
IN
T
N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
AS INDICATED
Lic. No. 044409
AARON P FREIDC
O M M O
N W
EAL
THOF
V
IR
G
IN
IA
P R O F
E
SSIONAL EN
G
IN
E E R
1 JUL 2026
/1
/2
:3 :1
A
M
C U s e rs \a fr e id
\O n e D ri v e
J e n s e n H u g h e s \D o c u m e n ts
\2
F
IR
E a fr e id
.r v t
L
IF
E S
A F
E T
Y F
L O
O R
P L
A N
GI101
7406712
FINAL
12939430
TKL TKL APF
L. PEED
H. PERRY
P. FAULKNER
D. CHASTAIN
7406712
M C
O L
F A
T L A
N T
IC
B
U
IL
D
IN
G
R E
N O
V A
T
IO
N S
G I1
GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
SCALE: 1/8" = 1'-0"
A1
LIFE SAFETY FLOOR PLAN
CP = 73-FT
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
Digitally signed by John K Avolis
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
STATION CONSTRUTION WON:
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
STATION DESIGN WON:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
A R
V A L S
T A T
IO
N
N O
R F O
L K V A
M A
R
IN
E C
O R
P S
A
IR
S T
A T
IO
N
C H
E R
R Y
P O
IN
T
N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
AS INDICATED
/1
/2
:0 :1
P
M
C U s e rs
\l u c a s .K
A Y
D O
S -D
A N
IE
L S
\D o c u m e n ts
\2
B
S
T R
U C
T lg g e lo
.r v t
G E
N E
R A
L N
O T
E S
S-001
7406712
12939445
LGG HON LGG
L. PEED
H. PERRY
P. FAULKNER
D. CHASTAIN
7406712
01 JUL 2026
M C
O L
F A
T L A
N T
IC
B
U
IL
D
IN
G
R E
N O
V A
T
IO
N S
S -0
SHEET INDEX
SHEET NO SHEET TITLE
S-001 GENERAL NOTES
S-002 STRUCTURAL NOTES
S-003 STRUCTURAL NOTES CONT.
S-101 FOUNDATION PLAN
S-102 ROOF FRAMING PLAN
S-201 SECTIONS
S-501 TYPICAL CONSTRUCTION DETAILS
S-502 TYPICAL CONSTRUCTION DETAILS
DESIGN CRITERIA
1. BUILDING CODES............................2024 IBC "INTERNATIONAL BUILDING CODE"
UFC 1-200-01, CHANGE 4, 17 DEC 2024 "DOD BUILDING CODE"
UFC 3-301-01, CHANGE 3, 03 FEB 2025 "STRUCTURAL ENGINEERING"
UFC 4-010-01, CHANGE 3, 24 MAY 2024 "MINIMUM ANTI-TERRORISM
STANDARDS FOR BUILDINGS"
2. BUILDING RISK CATEGORY......................................................................................... II
3. SUPERIMPOSED DEAD LOADS:
a) ROOF..................................................................................................... 15 PSF
4. DESIGN LIVE LOADS:
a) ROOF..................................................................................................... 20 PSF
b) MECHANICAL/ELECTRICAL ROOM ....................................................125 PSF
c) STORAGE ........................................................................................... 125 PSF
d) LOBBIES AND FIRST FLOOR CORRIDORS ..................................... 100 PSF
e) PRIVATE ROOMS................................................................................. 40 PSF
f) PUBLIC ROOMS................................................................................. 100 PSF
5. SNOW:
a) GROUND SNOW LOAD ....................................................................... 31 PSF
b) FLAT ROOF SNOW LOAD.................................................................... 22 PSF
c) SNOW EXPOSURE FACTOR, Ce .............................................................. 1.0
d) IMPORTANCE FACTOR, Is ....................................................................... 1.0
e) THERMAL FACTOR, Ct .............................................................................. 1.0
6. WIND
a) ULTIMATE WIND SPEED ................................................................. 139 MPH
b) NOMINAL WIND SPEED.................................................................... 107 MPH
c) WIND EXPOSURE CATEGORY..................................................................... B
d) INTERNAL PRESSURE COEFFICIENT ..................................................... 0.18
e) ROOF COMPONENTS AND CLADDING ........... SEE TABLE ON SHEET S001
f) WALL COMPONENTS AND CLADDING ........... SEE TABLE ON SHEET S001
7. SEISMIC:
a) SITE CLASS .................................................................................................. D
b) IMPORTANCE FACTOR, Ie ........................................................................ 1.0
c) MAPPED SPECTRAL RESPONSE ACCELERATION, Ss ................... 0.140 G
d) ONE SECOND PERIOD SPECTRAL RESPONSE COEFF., S1........... 0.052 G
e) SHORT PERIOD SPECTRAL RESPONSE COEFFICIENT, SDS ........ 0.120 G
f) ONE SEC PERIOD SPECTRAL RESPONSE COEFFICIENT, SD1...... 0.073 G
g) SEISMIC RESPONSE COEFFICIENT, Cs ............................................... 0.047
h) RESPONSE MODIFICATION FACTOR, R.......................EXISTING BUILDING
i) SEISMIC DESIGN CATEGORY .................................................................... B
j) BASIC SEISMIC FORCE RESISTING SYSTEM ............ EXISTING BUILDING
k) ANALYSIS PROCEDURE ............................ EQUIVALENT LATERAL FORCE
l) SEISMIC BASE SHEAR .................................. VX = VY = EXISTING BUILDING
8. RAIN:
a) RAIN INTENSITY, i ......................................................................... 4.25 IN/HR
A A
ZONE 45 5
3 2 3
3 2 3
Z O
WALLS
ROOF
COMPONENTS & CLADDING PRESSURE (PSF)
S-XXX
A1
A1
S-XXX
A1
S-XXX
GRID LINES - CENTER LINE
DETAIL NO.
ELEVATION NO.
SECTION NO.
SECTION
ELEVATION
DETAIL BUBBLE
GRID LINES - F.O. STUD/WALL
GRID NO.
SHEET NO. WHERE
SECTION IS SHOWN
SHEET NO. WHERE
ELEVATION IS SHOWN
SHEET NO. WHERE
DETAIL IS SHOWN
R O
O F
COMPONENTS & CLADDING NEW DESIGN WIND PRESSURE (ULTIMATE)
ZONE
EFFECTIVE
WIND
AREA
PRESSURE
(PSF)
PRESSURE
(PSF)
1 10 36 -64
1 20 31 -57
1 50 25 -47
1 100 20 -40
2 10 -88
2 20 -79
2 50 -66
2 100 -57
3 10
3 20
3 50
3 100
4 10 48 -52
4 20 46 -50
4 50 48 -47
4 100 41 -45
4 500 36 -40
5 10 -64
5 20 -60
5 50 -54
5 100 -50
5 500 -40
W A
L L S
-88
-79
-66
-57
Z O
1. SEE SPECIFICATIONS AND DEFERRED SUBMITTAL REQUIREMENTS ON SHEET
S-002 FOR REQUIRED SHOP DRAWING AND SUBMITTAL REQUIRMENTS TO BE
PROVIDED TO THE CONTRACTING OFFICER FOR REVIEW AND COMMENT.
2. STEEL REINFORCING LISTS AND QUANTITIES AND LENGTH OF ALL MATERIALS
ARE THE RESPONSIBILITY OF THE CONTRACTOR TO ASSURE COMPLIANCE
WITH THE PLANS. THE ENGINEER WILL NOT REVIEW THESE ITEMS.
3. REVIEW OF SHOP DRAWINGS IS FOR THE PURPOSE OF GENERAL COMPLIANCE
WITH THE CONTRACT DOCUMENTS. ALL ERRORS IN DETAILING, FABRICATION,
AND CORRECT FITTING OF ALL STRUCTURAL MEMBERS INCLUDING
COORDINATION WITH OTHER TRADES ARE THE RESPONSIBILITY OF THE
CONTRACTOR. SHOP DRAWING SUBMITTAL REVIEW DOES NOT CONSTITUTE
CHANGE ORDERS. ANY PROPOSED CHANGES MUST BE SUBMITTED IN A
LETTER OR DETAIL FOR APPROVAL.
4. SHOP DRAWINGS MUST BE SUBMITTED AT LEAST TWO WEEKS PRIOR TO THE
SCHEDULED FABRICATION DATE.
5. REPRODUCTION OF THESE STRUCTURAL DRAWINGS IS PROHIBITED FOR THE
PURPOSE OF PREPARING SHOP DRAWINGS. SUBCONTRACTOR/FABRICATOR
MUST PROVIDE INDEPENDENTLY CREATED DRAWINGS BASED ON THE
INFORMATION SHOWN IN THE CONTRACT DOCUMENTS.
SHOP DRAWINGS/SUBMITTALS:ABBREVIATIONS:
DESIGN BASIS: SYMBOLS:
Anchor Bolt American Concrete Institute Adjacent Above Finished Floor Aluminum Alternate American Plywood Institute Architect American Society for Testing Materials Below Between Block Blocking Beam Bottom of Footing Bottom Channel Cast-in-Place Control Joint / Ceiling Joist Ceiling Clear Concrete Masonry Unit Column Concrete Connection Construction Continuous Double Degree Demolish, Demolition Depressed Diameter Diagonal Dimension Ditto Drag Truss Drawing Dowel Existing Each Each Face Expansion Joint Electric, Electrical Elevation Equal Equipment Each Side Each Way Existing Expansion Exterior Finished Floor Finish Grade Finish, Finished Floor Joist Floor, Flooring Field Nail Foundation Face Of Face of Concrete Face of Masonry
Face of Steel (Studs) Far Side Feet Footing Future Gauge Galvanized Grade Beam Grade Beam Grade, Grading Glued Laminated Girder Truss Gusset Hold Down Header Hanger Horizontal High Point Height Heating/Ventilation/ Air Conditioning International Building Code Inside Diameter Inch Include Information Insulated Interior Joist Joint Length, Angle Laminated Pound Long Live Load Long Leg Horizontal Long Leg Vertical Low Point Louver Masonry Maximum Masonry Control Joint Mechanical Medium Mezzanine Manufacture, Manufacturer Minimum Miscellaneous Masonry Opening Metal North Not In Contract Number Nominal Near Side Not To Scale On Center Outside Diameter Opposite Hand, Overhead Opening Powder Acuated Fasteners Parallel
A.B.
A.C.I.
ADJ.
A.F.F.
AL.
ALT.
A.P.A.
ARCH.
A.S.T.M.
BLW.
BETWN.
BLK.
BLKG
BM
B.O.F.
BOTT
C C.I.P.
C.J.
CLG
CLR
CMU
COL
CONC
CONN
CONST
CONT
DBL
DEG
DEM
DEP
DIA
DIAG
DIM
DO
D.T.
DWG
DWL
(E)
EA.
E.F.
E.J.
ELEC
ELEV
EQ.
EQPT.
E.S.
E.W.
EXIST.
EXP.
EXT.
F.F.
F.G.
FIN
F.J.
FLR
F.N.
FND
F.O.
F.O.C F.O.M.
F.O.S.
F.S.
FT.
FTG
FUT.
GA
GAL
G.B.
GB
GD
GLB
G.T.
GUSS.
HD
HDR
HGR
HORIZ
H.P.
HT
H.V.A.C
IBC
I.D.
IN
INCL
INFO
INS
INT.
JST
JT.
L
LAM
LB
LG
L.L.
L.L.H.
L.L.V.
L.P.
LVR
MAS
MAX
MCJ
MECH
MED
MEZZ
MFR
MIN
MISC
M.O.
MTL
N.
N.I.C.
NO.
NOM
N.S.
N.T.S.
O.C.
O.D.
O.H.
OPNG
P.A.F.
PAR.
Pounds per Cubic Foot Penetration Pre-Engineered Metal Building Plate, Property Line Plate Plywood Panel Pounds per Square Foot Pounds per Square Inch Radius Reference Reinforcement Required Return Revision, Revised Roof Rafters Room Rough Opening Rough Sawn Roof Truss South Schedule Section Separation Sheet Similar Seismic Lateral Resisting System Specification(s) Square Stainless Steel Standard Stiffener Steel Structural Suspended Symmetrical Top & Bottom Tongue & Groove Thick, Thickness Top of Beam Top of Concrete Top of Footing Top of Parapet Top of Steel Top of Wall Tube Steel Typical Unless Noted Otherwise Unless Otherwise Noted Vapor Barrier Vertical With West Wood Without Water Proof Working Point Weight Welded Wire Fabric Welded Wire Mesh
P.C.F.
PENT.
PEMB.
PL.
P L
PLY.
PNL.
P.S.F.
P.S.I.
R.,RAD.
REF.
REINF.
REQ.
RET.
REV.
RF.
RFT.
RM.
R.O.
R.S.
R.T.
S.
SCHED.
SEC.
SEP.
SHT.
SIM.
SLRS
SPEC.
SQ.
S.S.
STD.
STIFF.
STL.
STRUCT
SUSP.
SYM
T&B T&G
THK
T.O.B.
T.O.C.
T.O.F.
T.O.P.
T.O.S.
T.O.W T.S.
TYP.
U.N.O.
U.O.N.
V.B.
VERT.
W/ W.
WD.
W/O W.P.
W.PT.
WT.
W.W.F.
W.W.M
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
STATION CONSTRUTION WON:
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
STATION DESIGN WON:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
A R
V A L S
T A T
IO
N
N O
R F O
L K V A
M A
R
IN
E C
O R
P S
A
IR
S T
A T
IO
N
C H
E R
R Y
P O
IN
T
N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
AS INDICATED
/1
/2
:0 :1
P
M
C U s e rs
\l u c a s .K
A Y
D O
S -D
A N
IE
L S
\D o c u m e n ts
\2
B
S
T R
U C
T lg g e lo
.r v t
S T
R U
C T
U R
A L
N O
T E
S
S-002
7406712
12939446
LGG HON LGG
L. PEED
H. PERRY
P. FAULKNER
D. CHASTAIN
7406712
01 JUL 2026
M C
O L
F A
T L A
N T
IC
B
U
IL
D
IN
G
R E
N O
V A
T
IO
N S
S -0
STRUCTURAL NOTES
2. FOUNDATION:1. GENERAL NOTES: 6. MECHANICAL ANCHORS IN HARDENED
CONCRETE AND MASONRY
(EXPANSION ANCHORS):
3. CONCRETE:
4. REINFORCING STEEL:
5. ADHESIVE, ANCHOR RODS AND REBAR
IN HARDENED CONCRETE (EPOXY)
ANCHORS):
1. ADHESIVE ANCHOR INSTALLATIONS MUST COMPLY WITH MANUFACTURER'S
WRITTEN INSTRUCTIONS AND SPECIFICATIONS, INLCUDING ICC-ES REPORTS
2. DUST MUST BE BLOWN FROM THE HOLE WITH COMPRESSED AIR TO
ENSURESURFACE. ADDITIONALLY, THE HOLE MUST BE BRUSHED WITH A NYLON
BRUSH THEN BLOWN AGAIN WITH COMPRESSED AIR.
3. ADHESIVE MUST ONLY BE APPLIED TO DRY SURFACES.
4. BASE MATERIAL TEMPERATURE MUST BE 40°F OR ABOVE AT TIME OF
INSTALLATION. FOR BEST RESULTS, MATERIAL SHOULD BE 70°F-80°F.
5. WHEN INSTALLING EPOXY ANCHORS INTO MASONRY, ANCHORS MUST BE
INSTALLED IN SOLID GROUTED CELLS ONLY.
6. CHEMICAL ANCHOR SYSTEMS:
A. CONCRETE: USE ONLY ADHESIVE ANCHOR SYSTEMS THAT HAVE BEEN
ISSUED AN ICC-ES REPORT IN ACCORDANCE WITH PROVISIONS OF OF ICC-ES
AC308. ANCHOR SYSTEM SHOULD BE APPROVED FOR USE IN CRACKED
CONCRETE AND SEISMIC DESIGN CATEGORIES A-F PER SECTION 2.0 OF THE
ICC-ES EVALUATION SERVICES REPORT. ANCHOR SYSTEM MUST BE
INSTALLED PER REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES
REPORT FOR SPECIFIC ANCHOR, AND AS REQUIRED BY THE MANUFACTURER.
B. GROUT-FILLED MASONRY UNITS: USE ONLY ADHESIVE ANCHORSYSTEMS
THAT HAVE BEEN ISSUED AN ICC-ES REPORT INACCORDANCE WITH
PROVISIONS OF ISS-ES AC58. ANCHORSYSTEMS MUST BE INSTALLED PER
REQUIREMENTS OF ICC-ESEVALUATION SERVICES REPORT FOR THE
SPECIFIC ANCHOR,AND AS REQUIRED BY THE MANUFACTURER.
7. ANCHOR RODS:
RODS MUST BE ASTM A36 THREADED RODS WITH ASTM A563 GRADE A NUTS AND
ANSI B18.22.1 TYPE A WASHERS, UNLESS OTHERWISE NOTED. ANCHORS
DESIGNATED AS ASTM A193 GRADE B7 THREADED RODS MUST USE ASTM A563
GRADE DH HEAVY HEX NUTS AND ASTM F436 WASHERS.
8. REINFORCEMENT BARS: ASTM A615 GRADE 60 STEEL.
9. REMOVE GREASE, OIL, RUST AND OTHER LAITANCE FROM RODS AND DOWELS
PRIOR TO INSTALLATION.
10. SPECIAL INSPECTION REQUIREMENTS MUST BE DICTATED BY SECTION 4.0 OF THE
ICC-ES EVALUATION SERVICES REPORT. SPECIAL INSPECTION MUST VERIFY
ANCHOR TYPE, ANCHOR DIMENSIONS, CONCRETE TYPE, CONCRETE
COMPRESSIVE STRENGTH, HOLE DIMENSIONS, ANCHOR SPACINGS, EDGE
DISTANCES, SLAB THICKNESS, ANCHOR EMBEDMENT, AND TIGHTENING TORQUE.
11. CONTRACTOR'S OPTION TO USE OTHER MANUFACTURER'S PRODUCTS ONLY
WITH PRIOR APPROVAL OF THE ENGINEER & CONTRACTING OFFICER. SUBMIT
MANUFACTURER'S LITERATURE AND PRODUCT INSTALLATION FOR REVIEW.
1. ANCHORS TO BE INSTALLED IN HOLES DRILLED WITH CARBIDE-TIPPED DRILL BITS.
ANCHORS TO BE INSTALLED PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. WHEN INSTALLING DRILLED EXPANSION ANCHORS IN EXISTING REINFORCED
CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE
EXISTING REINFORCEMENT.
3. MAINTAIN A MINIMUM CLEARANCE OF 25 mm[1"] BETWEEN THE REINFORCEMENT
AND THE DRILLED EXPANSION ANCHORS. EXPANSION ANCHORS MUST NOT BE
USED AT CONCRETE CURBS.
4. EXPANSION ANCHOR SYSTEMS:
A. CONCRETE: USE ONLY EXPANSION ANCHOR SYSTEMS THAT HAVE BEEN
ISSUED AN ICC-ES REPORT IN ACCORDANCE WITH THE PROVISIONS OF
ICC-ES AC193. ANCHOR SYSTEMS SHOULD BE APPROVED FOR USE WITH
CRACKED CONCRETE AND SEISMIC DESIGN CATEGORIES A-F PER
SECTION 2.0 OF THE ICC EVALUATIONS SERVICES REPORT. ANCHOR
SYSTEM MUST BE INSTALLED PER THE REQUIREMENTS OF THE ICC-ES
EVALUATION SERVICES REPORT FOR THE SPECIFIC ANCHOR, AND AS
REQUIRED BY THE MANUFACTURER.
B. MASONRY: USE ONLY EXPANSION ANCHOR SYSTEMS THAT HAVE BEEN ISSUED
AN ICC-ES REPORT IN ACCORDANCE WITH THE PROVISIONS OF ICC-ES AC01.
ANCHOR SYSTEMS SHOULD BE APPROVED FOR SEISMIC USE DETAILED IN THE
CONDITIONS OF USE LISTED IN THE ICC-ES EVALUATION SERVICES REPORT.
ANCHOR SYSTEM MUST BE INSTALLED PER THE REQUIREMENTS OF THE ICC-
ES EVALUATION SERVICES REPORT FOR THE SPECIFIC ANCHOR, AND AS
REQUIRED BY THE MANUFACTURER.
5. UNDERCUT ANCHOR SYSTEMS:
CONCRETE: USE ONLY UNDERCUT ANCHOR SYSTEMS THAT HAVE BEEN ISSUED AN
ICC-ES REPORT IN ACCORDANCE WITH THE PROVISIONS OF ICC-ES AC193.
ANCHOR SYSTEMS SHOULD BE APPROVED FOR USE IN CRACKED CONCRETE AND
SEISMIC DESIGN CATEGORIES A-F PER SECTION 2.0 OF THE ICC EVALUATIONS
SERVICES REPORT. ANCHOR SYSTEM MUST BE INSTALLED PER THE
REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES REPORT FOR SPECIFIC
ANCHOR, AND AS REQUIRED BY THE MANUFACTURER.
6. HERE THE MANUFACTURER'S INSTALLATION INSTRUCTIONS OR APPLICABLE ICC-ES
EVALUATION SERVICES REPORT CALL FOR THE APPLICATION OF AN INSTALLATION
TORQUE, THE SPECIFIED TORQUE MUST BE APPLIED WITH CALIBRATED TORQUE
WRENCH. THE SPECIFIED INSTALLATION TORQUE MUST NOT BE EXCEEDED.
7. ANCHORS ARE TYPICALLY AVAILABLE IN ELECTRO-GALVANIZED CARBON STEEL,
HOT DIPPED GALVANIZED CARBON STEEL, AND STAINLESS STEEL. USE OF
ELECTRO-GALVANIZED CARBON STEEL ANCHORS IS TYPICALLY LIMITED TO DRY,
INTERIOR LOCATIONS, UNLESS OTHERWISE NOTED. STAINLESS STEEL OR HOT-
DIPPED GALVANIZED ANCHORS ARE GENERALLY. SUITABLE FOR APPLICATIONS
EXPOSED TO EXTERIOR WEATHER CONDITIONS. FINAL AUTHORITY ON TYPE OF
ANCHOR COATING UTILIZED RESTS WITH THE STRUCTURAL ENGINEER OF RECORD
& CONTRACTING OFFICER AND MUST BE APPROVED BY SUCH.
8. EXPANSION ANCHORS FOR NON-VIBRATION ISOLATED MECHANICAL EQUIPMENT
RATED OVER 10HP ARE NOT PERMITTED BY ASCE 7-10 SECTION 13.6.5.5. ANCHORS
INSTALLED IN OVERHEAD CONDITIONS FOR NON- VIBRATION ISOLATED EQUIPMENT
WITH RECIPROCATING OR ROTATING MECHANISMS MUST BE UNDERCUT
ANCHORS.
9. THE SPECIAL INSPECTOR MUST BE ON THE JOBSITE CONTINUOUSLY DURING
ANCHOR INSTALLATIONS, UNLESS OTHERWISE NOTED IN ICC-ES ESR, TO VERIFY
ANCHOR TYPE, ANCHOR DIMENSIONS, CONCRETE TYPE, CONCRETE COMPRESSIVE
STRENGTH, HOLE DIMENSIONS ANCHOR SPACINGS, EDGE DISTANCES, SLAB
THICKNESS, ANCHOR EMBEDMENT, AND TIGHTENING TORQUE.
1. THE PROJECT SPECIFICATIONS (A BOOK OF SPECIFICATIONS WHEN PROVIDED)
ARE A PART OF THE CONTRACT DOCUMENTS. IF THERE IS A DISCREPANCY
FOUND BETWEEN THE SPECIFICATIONS AND THE DRAWINGS, SPECIFICATIONS
TAKE PRECEDENCE, HOWEVER THE MATTER MUST BE PROMPTLY SUBMITTED
TO THE CONTRACTING OFFICER FOR CLARIFICATION. WORK PERFORMED BY
THE CONTRACTOR WITHOUT SUCH A CLARIFICATION MUST BE AT
CONTRACTOR'S OWN RISK AND EXPENSE.
2. EXAMINE THE STRUCTURAL DRAWINGS AND THE SPECIFICATIONS AND NOTIFY
THE ENGINEER & CONTRACTING OFFICER OF DISCREPANCIES IN ELEVATIONS,
DIMENSIONS, AND SITE CONDITIONS INCLUDING ERRORS BEFORE PROCEEDING
WITH WORK. OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS
OF THE DRAWINGS (AND SPECIFICATIONS) MUST BE RESOLVED IN WRITING WITH
THE ENGINEER/ARCHITECT & CONTRACTING OFFICER PRIOR TO START OF
WORK.
3. THE DRAWINGS (AND SPECIFICATIONS) REPRESENT THE COMPLETED
STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION.
PROVIDE ALL MEASURES AND MEANS NECESSARY TO PROTECT PERSONS AND
THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES MUST INCLUDE,
BUT NOT BE LIMITED TO BRACING, SHORING, ETC. OBSERVATION VISITS BY THE
ARCHITECT OR ENGINEER DOES NOT INCLUDE REVIEW OF THESE MEASURES.
4. TYPICAL DETAILS MUST BE USED WHENEVER APPLICABLE WHETHER
SPECIFICALLY REFERENCED OR NOT.
5. DRAWINGS MUST NOT BE SCALED FOR CONSTRUCTION PURPOSES.
6. PIPES OR DUCTS MUST NOT BE PLACED IN STRUCTURAL MEMBERS UNLESS
SPECIFICALLY DETAILED OR APPROVED BY THE ENGINEER & CONTRACTING
OFFICER.
7. REFER TO ARCHITECTURAL DRAWINGS FOR THE FOLLOWING:
A. SIZE AND LOCATION OF DOOR AND WINDOW OPENINGS, UNLESS
OTHERWISE NOTED.
B. SIZE AND LOCATION OF INTERIOR AND EXTERIOR NON-BEARING PARTITIONS.
C. SIZE AND LOCATION OF CURBS, FLOOR DRAINS, SLOPES, DEPRESSED
AREAS, CHANGES IN LEVEL, RAMPS, CHAMFERS, GROOVES, INSERTS, ETC.,
EXCEPT AS SHOWN.
D. SIZE AND LOCATION OF FLOOR AND ROOF OPENINGS, EXCEPT AS SHOWN.
E. FLOOR AND ROOF FINISHES.
F. STAIR FRAMING AND DETAILS, EXCEPT AS SHOWN.
G. DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS.
8. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR THE
FOLLOWING:
A. PIPE RUNS, SLEEVES, HANGERS, TRENCHES, SLAB OPENINGS, ETC.,
EXCEPT AS SHOWN OR NOTED.
B. ELECTRICAL CONDUITS, BOXES, OUTLETS.
C. CONCRETE INSERTS FOR ELECTRICAL, MECHANICAL AND PLUMBING
FIXTURES.
D. SIZE AND LOCATION OF MACHINE AND EQUIPMENT BASES, ANCHOR BOLTS,
ETC.
9. ASTM REFERENCES ARE FROM THE LATEST ISSUE AND LATEST REVISION,
UNLESS OTHERWISE NOTED.
10. INVESTIGATE THE SITE DURING CLEARING AND EXCAVATION FOR UNSUITABLE
CONDITIONS, UNCONSOLIDATED AND UNDOCUMENTED FILLS, BURIED
STRUCTURES, UTILITIES, ETC., AND IMMEDIATELY NOTIFY THE
ARCHITECT/ENGINEER & CONTRACTING OFFICER OF SITE CONDITIONS NOT
REFLECTED ON THE DRAWINGS OR DIFFERENT FROM MAXIMUM OR MINIMUM
DIMENSIONS INDICATED, INCLUDING CONFLICT IN GRADES, ADVERSE SOIL
CONDITIONS, GROUNDWATER PRESENT, DEEPENED FOOTINGS, UNCOVERED
AND UNEXPECTED UTILITY LINES, ETC.
11. CONSTRUCTION MATERIALS, IF PLACED ON STRUCTURAL MEMBERS, MUST BE
SPREAD OUT SUCH THAT THE LOADING DOES NOT EXCEED THE DESIGN LIVE
LOADS. PROVIDE SHORING AND BRACING WHERE CONSTRUCTION LOADING
EXCEEDS THE DESIGN STRENGTH OF THE STRUCTURAL MEMBERS OR THE
STRUCTURAL STRENGTH HAS NOT BEEN ATTAINED OR THE STRUCTURE IS NOT
COMPLETE.
12. DETERMINE THE LOCATION OF UTILITY SERVICES IN AREAS TO BE EXCAVATED
BEFORE BEGINNING EXCAVATION. EXERCISE EXTREME CAUTION IN EXCAVATING
AND TRENCHING. DAMAGE CAUSED AS A RESULT OF FAILING TO EXACTLY
LOCATE AND PRESERVE EXISTING UNDERGROUND UTILITIES IS THE
RESPONSIBILITY OF THE CONTRACTOR.
13. STRUCTURAL DRAWINGS TO BE USED IN CONJUNCTION WITH ARCHITECTURAL
DRAWINGS BY: MBF ARCHITECTS
SLAB ON GRADE
FOOTINGS & ALL OTHER CONCRETE
MIN. f'c
4,000 psi
4,000 psi
11. PROVIDE CONSTRUCTION OR CONTROL JOINTS IN SLAB ON GRADE AS SHOWN ON
PLANS UNLESS SPECIFIED OTHERWISE. LOCATION OF JOINTS NOT SPECIFICALLY
INDICATED MUST BE REVIEWED BY THE STRUCTURAL ENGINEER & CONTRACTING
OFFICER PRIOR TO PLACING REINFORCING STEEL.
12. DRY PACK MUST BE ONE PART CEMENT AND 2 3/4 PARTS SAND WITH JUST
ENOUGH WATER TO HYDRATE CEMENT AND FORM A BALL SHOWING MOISTURE
ON THE SURFACE WHEN SQUEEZED. IT must BE RAMMED IN TIGHT TO MAXIMUM
DENSITY ATTAINABLE, AND MUST BE FROM A PRODUCT THAT SPECIFIES A
MINIMUM STRENGTH AT 28 DAYS OF 5000 psi.
13. NON-SHRINK GROUT MUST BE FROM A PRODUCT THAT SPECIFIES A MINIMUM
COMPRESSIVE STRENGTH AT 28 DAYS OF 7,000 psi PER ASTM C109. GROUTING OF
BASE PLATES PRIOR TO PLUMBING OF COLUMN IS NOT PERMITTED.
14. PROJECTING CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC., MUST BE
FORMED WITH A 3/4" CHAMFER OR TOOLED EDGE, UNLESS OTHERWISE NOTED.
15. CONCRETE WHICH DURING THE LIFE OF THE STRUCTURE must BE SUBJECT TO
FREEZING TEMPERATURES WHILE WET, MUST HAVE A WATER CEMENT RATIO NOT
EXCEEDING 0.45 BY WEIGHT AND MUST CONTAIN ENTRAINED AIR PER ACI 613.
SUCH CONCRETE MUST INCLUDE EXTERIOR SLABS, PERIMETER FOUNDATIONS,
EXTERIOR CURBS, ETC.
1. CEMENT MUST CONFORM TO ASTM C150, TYPE II / V
2. AGGREGATES FOR NORMAL WEIGHT CONCRETE MUST CONFORM TO ASTM C33, 1
1/2" MAXIMUM SIZE.
3. ADMIXTURES MUST NOT BE USED WITHOUT PRIOR APPROVAL OF THE ENGINEER &
CONTRACTING OFFICER. ADMIXTURES USED TO INCREASE THE WORKABILITY OF
THE CONCRETE MUST NOT REDUCE THE STRENGTH OF CONCRETE. FLY ASH
(POZZOLAN) IF PERMITED BY SPECIFICATIONS MUST NOT EXCEED 25% FOR SLAB
ON GRADE AND 25% FOR OTHER CONCRETE.
4. THE MIX DESIGN, INCLUDING PROPORTIONS OF MATERIALS FOR A ONE YARD
BATCH, MUST BE SUBMITTED TO THE ENGINEER OF RECORD & CONTRACTING
OFFICER FOR REVIEW PRIOR TO ORDERING CONCRETE.
5. READY-MIX CONCRETE MUST BE MIXED AND DELIVERED IN ACCORDANCE WITH
ASTM C94.
6. REINFORCING BARS AND INSERTS MUST BE SECURED IN PLACE PRIOR TO PLACING
CONCRETE.
7. CONDUITS EMBEDDED HORIZONTALLY IN THE SLAB MUST HAVE AN OUTSIDE
DIAMETER NO GREATER THAN 1/3 THE THICKNESS OF THE SLAB. CONDUIT MUST
NOT BE EMBEDDED IN A SLAB THAT IS LESS THAN 3 1/2" THICK. EXCEPT FOR LOCAL
OFFSETS, MIN. CLEAR DISTANCE BETWEEN CONDUITS MUST BE 6".
8. NON-STRUCTURAL STEEL MEMBERS EMBEDDED IN CONCRETE MUST BE
GALVANIZED OR PAINTED. DAMAGED GALVANIZED AREAS MUST BE REPAIRED
PRIOR TO EMBEDMENT.
9. CONCRETE MUST HAVE A MAXIMUM DRY DENSITY OF 150 pcf.
10. MINIMUM CONCRETE COMPRESSIVE STRENGTHS AT 28 DAYS.
1. DETAILING, FABRICATION AND ERECTION OF REINFORCING BARS MUST BE IN
ACCORDANCE WITH ACI MANUAL OF STANDARD PRACTICE FOR DETAILING
REINFORCED CONCRETE STRUCTURES, ACI 315-LATEST ADOPTED EDITION.
2. REINFORCING MUST BE ADEQUATELY SUPPORTED TO PREVENT DISPLACEMENT
BY CONCRETE PLACEMENT OR WORKERS.
3. REINFORCING BARS EXCEPT BARS TO BE WELDED MUST CONFORM TO THE
"STANDARD SPECIFICATION FOR DEFORMED BILLET STEEL BARS FOR CONCRETE
REINFORCEMENT", ASTM A615 GRADE 60. BARS TO BE WELDED MUST CONFORM
TO ASTM A706.
4. WELDING OF REINFORCING BARS TO BE IN ACCORDANCE WITH "STRUCTURAL
WELDING CODE-REINFORCING STEEL", AWS D1.4. REINFORCING STEEL TO BE
WELDED MUST HAVE A MAXIMUM CARBON EQUIVALENT (CE) OF 0.75. SPECIAL
INSPECTION IS REQUIRED. TESTING IS REQUIRED FOR WELDS THICKER THAN
5/16".
5. WHERE CONTINUOUS BARS ARE CALLED OUT IN FOOTINGS, SPLICES MAY BE
USED. WHERE BARS ARE SHOWN SPLICED, THEY MAY RUN CONTINUOUS AT
CONTRACTOR'S OPTION.
6. REINFORCING BAR BENDS MUST BE MADE COLD.
7. UNLESS OTHERWISE SHOWN, WALL VERTICAL REINFORCING MUST BE
POSITIONED AT THE CENTER OF THE WALL.
8. DOWELS BETWEEN FOOTINGS AND WALLS MUST BE THE SAME GRADE, SIZE, AND
SPACING AS VERTICAL REINFORCING.
9. REINFORCING BARS MUST BE PROVIDED WITH THE FOLLOWING CONCRETE
COVER:
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:.......3"
CONCRETE EXPOSED TO EARTH OR WEATHER:
NO.6 THROUGH NO.18 BAR .......................................................................... 2" NO.5 BAR, W31 OR D31 WIRE, AND SMALLER ..................................... 1 1/2"
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
SLABS, WALLS, JOISTS:
NO.14 AND NO.18 BAR ..................................................................... 1 1/2" NO.11 BAR AND SMALLER ................................................................. 3/4"
10. SLAB ON GRADE REINFORCEMENT MUST BE POSITIONED AT MID-DEPTH., UNLESS
NOTED OTHERWISE.
11. SHOP DRAWINGS FOR SIZE AND LAYOUT OF REINFORCING REBARS ARE
REQUIRED WHEN NOTED IN THE LIST OF REQUIRED SHOP DRAWINGS.
4. SUBMIT COMPACTION TEST REPORTS FOR FILL BY A QUALIFIED TESTING LAB TO
ARCHITECT/ENGINEER & CONTRACTING OFFICER BEFORE FOUNDATION
PLACEMENT. LOOSE SOIL AND FILL DIRT MUST BE COMPACTEDTO A MINIMUM OF
95% MAXIMUM DENSITY.
5. THE FOOTING EXCAVATIONS MUST BE KEPT FREE FROM LOOSE MATERIAL AND
STANDING WATER AND MUST BE NEAT AND TRUE TO LINE BEFORE CONCRETE IS
PLACED.
6. ABANDONED FOOTINGS, UTILITIES, ETC. THAT INTERFERE WITH NEW
CONSTRUCTION MUST BE REMOVED.
7. WALL FOOTINGS ARE CONTINUOUS POURED CONCRETE WITH CONTINUOUS
REINFORCING PLACED 3" CLEAR OF BOTTOM AND SIDES.
8. UNLESS OTHERWISE NOTED, WALL FOOTINGS ARE CENTERED UNDER WALLS AND
COLUMN FOOTINGS UNDER COLUMNS.
9. PROVIDE FOR DESIGN AND INSTALLATION OF CRIBBING, SHEATHING AND
SHORING REQUIRED TO SAFELY RETAIN GRADES.
10. PROVIDE FOR DE-WATERING OF EXCAVATIONS FROM SURFACE, GROUND, AND OR
SEEPAGE WATER.
DEFERRED SUBMITTALS:
1. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL
THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN
REVIEWED BY THE ARCHITECT OR ENGINEER OF RECORD AND
THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE
WITH THE DESIGN OF THE BUILDING.
A. LADDERS, GUARDRAILS, HANDRAILS AND THEIR COMPONENTS
B. SUPPORT ANCHORAGE OF MECHANICAL, ELECTRICAL AND
PLUMBING EQUIPMENT AND COMPONENTS
C. COLD-FORMED FRAMING AND LIGHT-GAUGE METAL TRUSSES,
CALCULATIONS AND SHOP DRAWINGS INCLUDING LAYOUT,
TYPICAL CONSTRUCTION DETAILS, AND CONNECTIONS (ITEMS
SHOWN IN PLANS ARE MINIMUM SIZES REQUIRED)
D. SLAB ON GRADE CONTROL JOINT PLAN (PE SEAL NOT
REQUIRED FOR THIS ITEM)
2. THE ABOVE LISTED SUBMITTAL DOCUMENTS SHALL BE STAMPED
AND SIGNED BY A REGISTERED PROFESSIONAL ENGINEER.
CONT. EXT.
FTG.
MIN. FTG. WIDTH MIN. FTG. THICKNESS MIN. EMBEDMENT
CONT. INT.
FTG.
PAD (SPREAD)
FTG.
2'-0"
MIN. FOOTING SIZES
12" 18"
18"
18"
12"
12"
2'-0"
3'-0"
1. FOUNDATION DESIGN IN BASED ON A PRESUMPTIVE ALLOWABLE SOIL BEARING
PRESSURE OF 1500 PSF.
2. FOOTING DEPTHS SHOWN ARE A MINIMUM AND MAY REQUIRE DEEPENING
BASED ON SITE CONDITIONS.
3. FOOTINGS MUST BEAR ON FIRM UNDISTURBED OR COMPACTED SOIL. MINIMUM
FOOTING DIMENSIONS AND EMBEDMENTS MUST BE AS FOLLOWS:
1. STRUCTURAL METAL STUDS MUST BE COLD-FORMED, AND MUST BE OF MINIMUM
SIZE AND GAGE AS SHOWN ON PLANS - FINAL DESIGN PER DELEGATED DESIGN
ENGINEER. ANY SIZES SHOWN ARE FOR BUDGET PRICING PURPOSES ONLY.
2. TRUSS SUPPLIER TO SUBMIT SEALED TRUSS SHOP DRAWINGS AND
CALCULATIONS.
3. TRUSS SUPPLIER TO PROVIDE ALL ACCESSORIES REQUIRED TO SUPPORT AND
ANCHOR TRUSSES, INCLUDING, BUT NOT LIMITED TO, CLIPS, BRACES, HANGERS,
FASTENERS, ETC.
4. TRUSS FRAMING SYSTEM IS A PERFORMANCE SPECIFICATION. TRUSS FRAMING
SHOWN ON PLANS IS SCHEMATIC ONLY. TRUSS SUPPLIER TO PROVIDE FINAL ROOF
SYSTEM LAYOUTS WHICH MEET THE INTENT OF THE SCHEMATIC LAYOUT. RUSS
LANS THAT CHANGE THE INTENDED LOAD PATH TO THE FOUNDATIONS WILL NOT
BE ACCEPTED. THE USE OF OVERBUILD AREAS IS ALLOWED WHERE REQUIRED.
5. ALL METAL STUDS MUST HAVE MINIMUM 1 5/8" FLANGES AND 50 KSI YIELD STRESS,
UNLESS NOTED OTHERWISE.
6. METAL STUDS FOR ROOF OVER-BUILD AREAS SHALL BE 3 5/8", 20 GAGE, UNLESS
NOTED OTHERWISE
7. METAL STUD MEMBERS MUST NOT BE CUT FOR PLUMBING OR WIRING UNLESS
DETAILED ON THE APPROVED SHOP DRAWINGS.
7. STRUCTURAL METAL STUDS:
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
STATION CONSTRUTION WON:
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
STATION DESIGN WON:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
DRAWFORM REVISION: 25 AUGUST 2020
IP
T M
A R
V A L S
T A T
IO
N
N O
R F O
L K V A
M A
R
IN
E C
O R
P S
A
IR
S T
A T
IO
N
C H
E R
R Y
P O
IN
T
N
C
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
A
T L A
N T
IC
AS INDICATED
/1
/2
:0 :1
P
M
C U s e rs
\l u c a s .K
A Y
D O
S -D
A N
IE
L S
\D o c u m e n ts
\2
B
S
T R
U C
T lg g e lo
.r v t
S T
R U
C T
U R
A L
N O
T E
S C
O N
T
S-003
7406712
12939447
LGG HON LGG
L. PEED
H. PERRY
P. FAULKNER
D. CHASTAIN
7406712
01 JUL 2026
M C
O L
F A
T L A
N T
IC
B
U
IL
D
IN
G
R E
N O
V A
T
IO
N S
S -0
8. POWDER ACTUATED FASTENERS IN
HARDENED CONCRETE, MASONRY,
AND STEEL (SHOT PINS):
9. MASONRY:
CONCRETE MASONRY UNITS
MASONRY COMPONENTS
DESIGN STRENGTH: f'm = 2000 psi
MORTAR (TYPE S)
GROUT
STRENGTH @ 28 DAYS
2000 psi
3000 psi
1800 psi
1. MASONRY WORK MUST CONFORM TO INTERNATIONAL BUILDING CODE
(IBC), LATEST ADOPTED EDITION AS LISTED HEREIN.
2. CONCRETE MASONRY UNITS MUST BE MEDIUM WEIGHT UNITS IN
ACCORDANCE WITH ASTM C90 WITH MAXIMUM LINEAR SHRINKAGE OF
0.065%.
3. CEMENT MUST BE AS SPECIFIED FOR CONCRETE.
4. MORTAR MUST CONFORM TO ASTM C270
EXCERPTS FROM ASTM C270:
TABLE 2 PROPERTY SPECIFICATION REQUIREMENTS
A
MORTAR TYPE
AVG. COMPRESSIVE
STRENGTH AT 28
DAYS, MIN.
WATER
RETENTION,
MIN. %
AIR
CONTENT,
MAX. %B
AGGREGATE RATIO
(MEASURED IN DAMP,
LOOSE CONDITIONS)
CEMENT-
LIME
MORTAR
CEMENT
MASONRY
CEMENT
M
S
N
O
M
S
N
O
M
S
N
O
2500 psi
1800 psi
750 psi
350 psi
2500 psi
1800 psi
750 psi
350 psi
2500 psi
1800 psi
750 psi
350 psi
75 12
75 12
75 14
75 14
75 12
75 12
75 18
75 18
75 20
75 20
C
C
C
C
D
D
NOT LESS THAN 2 1
AND NOT MORE THAN
3 1
2 THE SUM OF
SEPARATE VOLUMES
OF CEMENTITIOUS
MATERIALS
A
LABORATORY PREPARED MORTAR ONLY
SEE NOTE:
WHEN STRUCTURAL REINFORCEMENT IS INCORPORATED IN CEMENT LINE OR
CEMENT MORTAR, THE MAX. AIR CONTENT MUST BE 12%.
WHEN STRUCTURAL REINFORCEMENT IS INCORPORATED IN MASONRY OR
CEMENT MORTAR, THE MAX. AIR CONTENT MUST BE 18%.
B
C
D
PROPORTIONS BY VOLUME (CEMENTITIOUS MATERIALS)
MORTAR TYPE
PORTLAND
CEMENT OR
BLENDED
CEMENT
CEMENT-
LIME
MORTAR
CEMENT
M
S
N
O
M
M
S
S
N
O
1/2
M
M
S
S
N
O
1/2
M S N M S N
TABLE 1 PROPORTION SPECIFICATION REQUIREMENTS
MASONRY
CEMENT
MORTAR
CEMENT
NOT LESS THAN
2 1
4 AND NOT
MORE THAN 31
THE SUM OF
SEPARATE
VOLUMES OF
CEMENTITIOUS
MATERIALS
AGGREGATE
RATIO (MEASURED
IN DAMP, LOOSE
CONDITIONS)
HYDRATED
LIME OR LIME
PUTTY
1/4
OVER 1/4 TO 1/2
OVER 1/2 TO 1 1/4
OVER 1 1/4 TO 2 1/2
5. MORTAR JOINTS MUST BE STRAIGHT, CLEAN AND UNIFORM IN THICKNESS,
AND MUST BE TOOLED AS SHOWN ON THE PLANS OR AS SPECIFIED (FLUSH
JOINTS IF NO SPECIAL TREATMENT SPECIFIED). UNLESS OTHERWISE
SPECIFIED OR DETAILED ON THE PLANS, HORIZONTAL AND VERTICAL MORTAR
JOINTS MUST BE 3/8" THINK WITH FULL MORTAR COVERAGE ON THE FACE
SHELL.
6. OVERHANGING MORTAR DROPPINGS AND DEBRIS MUST BE REMOVED FROM
CELLS RECEIVING GROUT. FAILURE TO REMOVE DEBRIS MUST BE CAUSE FOR
REJECTION OF WALL AND REPAIR OR REWORK NECESSARY MUST BE
ENTIRELY AT CONTRACTORS EXPENSE.
7. VERTICAL HEAD JOINTS MUST BE BUTTERED WELL FOR A THICKNESS EQUAL
TO THE FACE SHELL OF THE BLOCK AND THESE JOINTS MUST BE SHOVED
TIGHTLY SO THAT THE MORTAR BONDS WELL TO BOTH BLOCKS. IF IT IS
NECESSARY TO MOVE A BLOCK SO AS TO OPEN A JOINT, THE BLOCK MUST BE
REMOVED FROM THE WALL, CLEANED AND SET IN FRESH MORTAR.
8. GROUT MUST CONFORM TO ASTM C476.
EXCERPTS FROM ASTM C476:
TABLE 2103.12
GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
PARTS BY VOLUME
OF PORTLAND
CEMENT OR
BLENDED CEMENT
PARTS BY
VOLUME OF
HYDRATED
LIME OR LIME
PUTTY
AGGREGATE, MEASURED IN A DAMP,
LOOSE CONDITION
FINE COARSE
TYPE
FINE GROUT 1 0-1/10
1 0-1/10
COARSE
GROUT
2 1/4-3 TIMES THE
SUM OF THE
VOLUMES OF THE
CEMENTITIOUS
MATERIALS
2 1/4-3 TIMES THE
SUM OF THE
VOLUMES OF THE
CEMENTITIOUS
MATERIALS
1-2 TIMES THE SUM
OF THE VOLUMES
OF THE
CEMENTITIOUS
MATERIALS
STRUCTURAL NOTES
10. STRUCTURAL STEEL:
1. THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL MUST BE IN
ACCORDANCE WITH "AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS"
AND STEEL CONSTRUCTION MANUAL AISC 360, LATEST ADOPTED EDITION.
EXCEPT AS AMENDED IN IBC CHAPTER 22.
2. CONNECTIONS MUST BE DETAILED IN ACCORDANCE WITH LATEST EDITION OF
AISC "DETAILING FOR STEEL CONSTRUCTION".
3. STEEL FURNISHED FOR STRUCTURAL LOAD-CARRYING PURPOSES MUST BE
PROPERLY IDENTIFIED FOR CONFORMITY TO THE SPECIFIED GRADES SHOWN
BELOW AND IN ACCORDANCE WITH ASTM STANDARDS AND PROVISIONS OF IBC
CHAPTER 22. STEEL THAT IS NOT READILY IDENTIFIABLE AS TO GRADE FROM
MARKING AND TEST RECORDS MUST BE TESTED TO DETERMINE CONFORMITY TO:
A. WIDE FLANGE ASTM A992 (Fy=50 ksi) B. ANGLES AND CHANNELS ASTM A36 (Fy=36 ksi) C. PLATES ASTM A36 (Fy=36 ksi) D. HSS (RECTANGULAR) ASTM A500 GRADE C (Fy=50 ksi)
E. ANCHOR BOLTS ASTM F1554 GRADE 55
4. COLUMN ENDS MUST BE MILLED.
5. EXTERIOR STRUCTURAL STEEL PERMANENTLY EXPOSED TO THE WEATHER MUST
BE HOT-DIPPED GALVANIZED AFTER FABRICATION. ZINC COATING MUST
CONFORM TO ASTM A123 (G-60 U.O.N.).
6. WELDING DONE AFTER GALVANIZING MUST BE PROTECTED WITH TWO COATS OF
GALVANIZING PROTECTANT METALLIC BARRIER. CONTRACTOR MUST USE
VENTILATION WHILE PERFORMING THIS WORK AS REQUIRED BY OSHA.
7. STEEL FABRICATION MUST BE PERFORMED IN AN APPROVED FABRICATION SHOP.
8. STEEL FABRICATOR MUST VERIFY DIMENSIONS WITH ARCHITECTURAL AND
STRUCTURAL DRAWINGS.
9. METAL ITEMS, INCLUDING CONNECTORS, EXPOSED TO THE WEATHER MUST BE
HOT-DIPPED GALVANIZED AFTER FABRICATION.
10. STRUCTURAL STEEL MUST BE DELIVERED TO THE JOB SITE FREE OF EXCESSIVE
RUST, MILL SCALE, GREASE, ETC.
11. SUBMIT SHOP DRAWINGS TO THE STRUCTURAL ENGINEER & CONTRACTING
OFFICER FOR REVIEW PRIOR TO FABRICATION FOR STRUCTURAL STEEL
MEMBERS AND ACCESSORIES.
11. STEEL DECK:
1. METAL DECKING MUST BE DESIGNED, FABRICATED AND ERECTED IN
ACCORDANCE WITH THE LATEST EDITION OF THE STEEL DECK INSTITUTE
SPECIFICATIONS.
2. WELDING OF METAL DECKING MSUT CONFORM TO AWS D1.3, "STRUCTURAL
WELDING CODE-SHEET STEEL"
3. METAL DECK MUST BE GALVANIZED AND SHOP-PRIMED STEEL SHEET: ASTM
A653, STRUCTURAL STEEL (55) GRADE 33 or 50, G60 ZINC COATING; CLEAN, PRETREATED, AND PRIMED WITH MANUFACTURER'S STANDARD BAKED-ON, RUST-INHIBITIVE PRIMER. COLOR MUST BE THE MANUFACTURER'S STANDARD
UNLESS OTHERWISE NOTED ON THE ARCHITECTURAL PLANS
4. METAL DECK MUST HAVE A 3-SPAN CONDITION UNLESS NOTED OTHERWISE AND
HAVE HAVE INTERLOCKING SEAM SIDELAPS.
5. FASTEN ROOF DECK PANELS TO STEEL SUPPORTING MEMBERS WITH #12
SCREWS AS INDICATED ON THE ROOF DECK DETAIL ON THESE DRAWINGS.
FASTEN SIDELAPS OF PANELS BETWEEN SUPPORTS WITH No. 10 SELF-DRILLING
CARBON STEEL SCREWS AS INDICATED ON THE ROOF DECK DETAIL ON THESE
DRAWINGS. INSTALL DECK ENDS OVER SUPPORTING FRAMING WITH A 1-1/2"
MINIMUM END BEARING AND LAP JOINTS 2". FASTEN ROOF DECK PANELS TO
DIAPHRAGM PERIMETER, i.e. EDGE ANGLES, WITH #12 SCREWS AT 6" O.C.
TYPICAL UNLESS NOTED OTHERWISE.
6. FASTEN FLOOR DECK PANEL TO SUPPORT WITH 5/8" PUDDLE WELDS AT 12" O.C.
EXCEPT FOR END SPANS OR LAPS, WHICH SHOULD HAVE PUDDLE WELDS AT 6"
O.C. PROVIDE MINIMUM (4) #10 SELF TAPPING HEX HEAD SCREWS EQUALLY
SPACED BETWEEN SUPPORTS (OR A MAXIMUM OF 18" O.C.)
7. PROVIDE MISCELLANEOUS DECK ACCESSORIES NOT SPECIFICALLY NOTED ON
THESE DRAWINGS AS REQUIRED TO SUBSTRATE A COMPLETE DECK
INSTALLATION. THESE ACCESSORIES MUST INCLUDE RIDGE AND VALLEY PLATES,
FINISH STRIPS, END CLOSURES, REINFORCING CHANNELS, AND WELD COVER
PLATES AT CHANGES IN DIRECTION OF DECK PANELS ACCORDING TO DECK
MANUFACTURER'S WRITTEN INSTRUCTIONS.
8. ACCESSORIES ACCORDING TO APPLICABLE SPECIFICATIONS AND COMMENTARY
IN SDI PUBLICATION No. 30, MANUFACTURER'S WRITTEN INSTRUCTIONS AND
REQUIREMENTS IN THESE DOCUMENTS.
9. INSTALL TEMPORARY SHORING BEFORE PLACING DECK PANELS, IF REQUIRED TO
MEET DEFLECTION LIMITATIONS.
10. PLACE DECK PANELS ON SUPPORTING FRAME AND ADJUST TO FINAL POSITION
WITH ENDS ACCURATELY ALIGNED AND BEARING ON SUPPORTING FRAME
BEFORE BEING PERMANENTLY FASTENED. DO NOT STRETCH OR CONTRACT
SIDELAP INTERLOCKS.
1. POWDER ACTUATED FASTENING SYSTEMS:
A. CONCRETE: FOR GENERAL CONCRETE AND LIGHTWEIGHT CONCRETE:
POWDER ACTUATED FASTENING SYSTEMS MUST BE INSTALLED PER
REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES REPORT FOR THE
SPECIFIC FASTENER, AND AS REQUIRED BY THE MANUFACTURER.
B. MASONRY: POWDER ACTUATED FASTENING SYSTEMS MUST BE INSTALLED
PER THE REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES REPORT
FOR SPECIFIC FASTENER, AND AS REQUIRED BY THE MANUFACTURER.
C. STEEL: POWDER ACTUATED FASTENING SYSTEMS MUST BE INSTALLED PER
THE REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES REPORT FOR
THE SPECIFIC FASTENER, AND AS REQUIRED BY THE MANUFACTURER.
2. WHEN INSTALLING POWDER ACTUATED FASTENERS IN EXISTING NON-
PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID
HITTING OR DAMAGE TO THE EXISTING REINFORCING BARS. MAINTAIN A
MINIMUM CLEARANCE OF 1" BETWEEN THE REINFORCEMENT AND THE
FASTENER.
3. POWDER ACTUATED FASTENERS ARE NOT PERMITTED BY ASCE 7-16 SECTION
13.4.5 FOR SEISMIC TENSION LOAD APPLICATIONS. POWDER ACTUATED
FASTENERS MUST NOT BE USED TO CARRY SEISMIC TENSION LOADS (EXCEPT
FOR VERTICAL SEISMIC LOAD PRODUCED BY SELF-WEIGHT OF THE
COMPONENTS SUPPORTED) OR IN CRACKED CONCRETE UNLESS PRE-
APPROVED FOR SUCH LOADING BY THE ENFORCEMENT AGENCY.
4. THE USE OF POWDER DRIVEN FASTENERS FOR TENSION LOADS IS LIMITED TO
SUPPORT OF MINOR LOADS LIKE ACOUSTICAL CEILINGS, DUCTWORK CONDUITS,
ETC.
5. ALLOWABLE TENSION LOADS MUST BE LIMITED TO LESS THAN 100 POUNDS.
6. POWDER ACTUATED FASTENERS MAY BE USED FOR SEISMIC SHEAR, WHEN
THEY ARE SPECIFICALLY LISTED FOR SERVICE IN RESISTING LATERAL LOADS IN
AREAS SUBJECT TO EARTHQUAKE.
7. MINIMUM EDGE DISTANCE FOR ACTUATED FASTENERS MUST BE THE LARGER
OF THE VALUES GIVEN IN ASTM E 1190 OR THE APPLICABLE ICC-ES EVALUATION
SERVICES REPORT.
9. SPECIFIED COMPRESSIVE STRENGTH- PROPORTIONS ESTABLISHED BY 28-DAY
COMPRESSIVE STRENGTH TESTS IN ACCORDANCE WITH TEST METHOD C 1019
THAT OBTAIN THE SPECIFIED COMPRESSIVE STRENGTH. THE GROUT MUST BE
MIXED TO A SLUMP OF 8 in. TO 11in. AS DETERMNINED BY TEST METHOD C 143/C 143M AND MUST HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 psi AT 28
DAYS.
10. CELLS BELOW GRADE MUST BE FULLY GROUTED UNLESS OTHERWISE NOTED.
ADDITIONALLY, CELLS WITH REINFORCING MUST BE FILLED SOLID WITH
GROUTED UNLESS OTHERWISE NOTED WITHIN THE SECTIONS AND TYPICAL
DETAILS.
11. GROUT MUST BE CONSOLIDATED WITH A MECHANICAL VIBRATOR. MINIMUM 4000
rpm, 3/4" MAXIMUM HEAD. PROVIDE INSPECTION AND CLEANOUT HOLES AT THE
BASE OF GROUTED CELLS FOR LIFTS GREATER THAN 5'-0".
12. WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL
CONSTRUCTION JOINTS MUST BE FORMED BY STOPPING THE GROUT POUR 1 1/2"
BELOW TOP OF THE UPPERMOST UNIT.
13. UNLESS OTHERWISE NOTED, MASONRY MUST BE CONSTRUCTED WITH A
RUNNING BOND PATTERN.
14. ELECTRIC CONDUIT BOXES AND/OR OTHER OBSTRUCTIONS ARE NOT PERMITTED
IN CELLS CONTAINING REINFORCING, UNLESS APPROVED BY THE ENGINEER &
CONTRACTING OFFICER.
15. UNLESS OTHERWISE SHOWN ON THE PLANS, LAP SPLICES OF REINFORCING
STEEL IN MASONRY MUST BE PER SCHEDULE.
16. HORIZONTAL REINFORCEMENT BARS MUST BE PLACED IN BOND BEAM MASONRY
UNITS.
17. LINTEL REINFORCEMENT BARS MUST BE PLACED IN LINTEL BEAM BLOCK.
18. VERTICAL REINFORCEMENT BARS MUST BE PLACED AT THE CENTER OFTHE
WALL UNLESS OTHERWISE SHOWN. VERTICAL BARS ARE TO BE TIED OR
OTHERWISE FIXED IN POSITION AT INTERVALS OF NOT MORE THAN 200 BAR
DIAMETERS AND AT TOP AND BOTTOM.
19. ANCHOR BOLTS MUST BE SET WITH TEMPLATES AND HELD IN PLACE PRIOR TO
GROUTING.
20. PROVIDE A MINIMUM OF ONE BAR DIAMETER OF GROUT BETWEEN MAIN
REINFORCING AND MASONRY UNITS. PROVIDE A MINIMUM OF 1" GROUT AROUND
BOLTS EMBEDDED IN MASONRY.
21. FOR MASONRY WORK INSPECTIONS SEE INSPECTION AND TESTING
SPECIFICATIONS.
22. REFER TO MASONRY CONSTRUCTION DETAILS ON SHEET S-501 AND S-502.
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
(E ) H
SS4X
4X
5/
(E ) H
SS4X
4X
5/
(E ) H
SS4X
4X
5/ 16(E
) H
SS4X
4X 5/
(E ) H
SS4X
4X
5/
(E ) H
SS4X
4X
5/
MASONRY WALL
INFILL - SEE
ARCH. (TYP.)
HATCHED AREAS
INDICATE CONC. SLAB
INFILL - SEE PLAN
NOTES & B4/501 (TYP.)
NEW MASONRY
PARTITION - SEE
ARCH. & PLAN
NOTES (TYP.)
EXISTING WALL &
FOOTING (TYP.)
EXISTING WALL &
FOOTING (TYP.)
EXISTING WALL &
FOOTING (TYP.)
NEW MASONRY
PARTITION - SEE
ARCH.
This is the start of the file's text. The full file is on GovTribe.