This file contains mechanical drawings showing detailed plumbing and drainage layouts for a Local Guard Force (LGF) bathroom building refurbishment project at the U.S. Embassy compound in South Sudan, under the USAID Engineering Support Program II.

The drawings include comprehensive plumbing details with floor plans and section views showing the placement and specifications of waste water pipes (WWP Ø50mm), soil water pipes (SWP Ø110mm), vent pipes (VP Ø50/110mm), floor drains, rodding eyes, vent cowls, and connections to the sewage collection sump. The plans detail the locations of bathroom fixtures including water closets, wash hand basins, urinals with partitions, and shower heads. The drawings provide specific pipe routing information including high-level and low-level installations, directions of flow, and connection points. The technical specifications are drawn to a 1:100 scale and include five detailed sections (A through E) showing both plan and elevation views of the plumbing system layout.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DIRECTION OF FLOW

VENT COWL

FLOOR DRAIN

WASH HAND BASIN

WATER CLOSET

RODDING EYE COVER (RE)

TYPICAL VENT PIPE (VP)Ø50/110mm

TYPICAL WASTE WATER PIPE (WWP)Ø50mm

TYPICAL SOIL WATER PIPE (SWP)Ø110mm

LEGEND

FLOOR CLEANOUT COVER

URINAL

URINAL PARTITION

VENT PIPE

SOIL WASTE PIPE

LOW LEVEL

VP

LL

SWP

WASTE WATER PIPESWP

HIGH LEVELHL

SHOWER HEAD

Ø50mm VP RISE

TO LL IN WALL

Ø110 VP FROM BELOW TO

HIGH LEVEL TO VENT

SEWAGE COLLECTION SUMP

Ø50mm VP@LL IN WALL

Ø50mm VP RISE TO HL IN WALL

TO CONNECT VENT COWL

Ø50mm WWP RUN ON

WALL OUTSIDE

Ø50mm SWP DROP

SEWER COLLECTION SUMP

CONTAINING SEWER TRANSFER PUMP

Ø50mm WWP RUN ON

WALL OUTSIDE

Ø50mm WWP IN SCREED

Ø110mm RODDING EYE@LL

IN WALL WITH CAP

Ø110mm RODDING EYE@LL

IN WALL WITH CAP

Ø50mm RODDING EYE

WITH CAP@LL

Ø50mm VP FB/ABOVE

WITH RODDING EYE

WITH CAP BELOW

Ø50mm WWP RUN

ON WALL OUTSIDE

Ø110mm RODDING EYE@LL

IN WALL WITH CAP

Ø110mm IN FLOOR SCREED

Ø110mm SWP@LL

Ø50mm VP RISE TO HL IN WALL

TYPICAL Ø50mm WWP IN

FLOOR SCREED

Ø50mm WWP@LL IN WALL

Ø50mm VP RISE LL/HL IN

WALL TO TERMINATE ON

WALL MOUNTED VENT COWL

TYPICAL Ø50mm WWP @LL

Ø50mm VP IN CEILING VOID

Ø50mm VP RISES TO HL IN

WALL

Ø50mm VP IN

CEILING VOID

Ø50mm VP RISE LL/HL IN

WALL TO TERMINATE ON

WALL MOUNTED VENT COWL

TYPICAL Ø50mm WWP IN

FLOOR SCREED

Ø50mm VP@LL IN WALL

Ø50mm VP RISE

TO HL IN WALL

Ø50mm VP RISE TO LL IN WALL

Ø50mm VP@LL IN WALL

Ø50mm RODDING

EYE WITH CAP

Ø50mm VP RISE

TO CEILING VOID

IN WALL

Ø50mm RUN IN

CEILING VOID

Ø110mm SWP@LL IN WALL

Ø110mm SWP DISCHARGE

TO SEWAGE COLLECTION

SUMP

Ø50mm WWP IN

FLOOR SCREED

Ø50mm WWP DROP TO

FLOOR SCREED

Ø50mm WWP DROP TO

FLOOR SCREED

Ø50mm WWP DROP TO

CONNECT PIPE @LL OUTSIDE

Ø50mm WWP DROP TO

CONNECT PIPE @LL OUTSIDE

Ø50mm WWP DROP TO

CONNECT WWP @LL OUTSIDE

Ø110mm WWP IN

FLOOR SCREED

Ø110mm SWP TO

CONNECT MANHOLE

Ø110mm SWP TO

CONNECT MANHOLE

Ø50mm RODDING

EYE WITH CAP

TYPICAL Ø50mm

RODDING EYE

WITH CAP

VENT COWL

Ø50mm VP@ LL IN WALL

TYPICAL Ø50mm

RODDING EYE WITH CAP

TYPICAL Ø50mm RODDING

EYE WITH CAP

Ø50mm RODDING EYE@LL IN

WALL WITH CAP

Ø110mm IN FLOOR SCREED

1:100

A

E

B

C

D

Ø50mm VP RISES TO HL IN

WALL

Ø50mm VP RISES TO HL IN

WALL

REV.NO. DATE DRWN

CHKD

DESIGNED BY:

DRAWN BY:

CROSS CHK'D BY:

APPROVED BY:

DATE:

SHEET CHK'D BY:

REMARKS

M .M

M.M

FA

SEPTEMBER 06, 2024

DRAINAGE LAYOUT

USAID ENGINEERING SUPPORT PROGRAM II:

EMBASSY COMPOUND

LOCAL GUARD FORCE (LGF) BATHROOM BUILDING

REFURBISHMENT WORKS

DRAWING NO.: M-101

PROJECT NO.

FILE NAME:

SCALE: NTS @A3

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1310 N Courthouse Rd, Ste 610 Arlington, VA 22201 Ph: +1 703 829 6133

GF

RF

12345678

Level 0

Level 1

SECTION B DETAIL

GF

RF

Level 0

SECTION A DETAIL

GF

RF

12345678

Level 0

Level 1

SECTION C DETAIL

GF

RF

Level 0

Level 1

SECTION D DETAIL

GF

RF

Level 0

Level 1

SECTION E DETAIL

REV.NO. DATE DRWN

CHKD

DESIGNED BY:

DRAWN BY:

CROSS CHK'D BY:

APPROVED BY:

DATE:

SHEET CHK'D BY:

REMARKS

M ,M

M.M

FA

SEPTEMBER 06, 2024

PLUMBING DETAILS

USAID ENGINEERING SUPPORT PROGRAM II:

EMBASSY COMPOUND

LOCAL GUARD FORCE (LGF) BATHROOM BUILDING

REFURBISHMENT WORKS

DRAWING NO.: M-102

PROJECT NO.

FILE NAME:

SCALE: NTS @A3

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1310 N Courthouse Rd, Ste 610 Arlington, VA 22201 Ph: +1 703 829 6133

LGF BATHROOM BUILDING REFURBISHMENT_MECHANICAL DESIGN DRAWINGS _Rev 2-Layout1.pdf (p.1)
Layout1
LGF BATHROOM BUILDING REFURBISHMENT_MECHANICAL DESIGN DRAWINGS _Rev 2-Layout2.pdf (p.2)
Layout1

File details come from the government source that posted it. Updated .