Appendix E - Mechanical Drawings.pdf
PDF 865 KB Posted
- Attached to
- Procure services to refurbish LGF Bathroom building works within the U. S. Embassy Juba, South Sudan
- Solicitation number
- 72066825Q00004
About this file
This file contains mechanical drawings showing detailed plumbing and drainage layouts for a Local Guard Force (LGF) bathroom building refurbishment project at the U.S. Embassy compound in South Sudan, under the USAID Engineering Support Program II.
The drawings include comprehensive plumbing details with floor plans and section views showing the placement and specifications of waste water pipes (WWP Ø50mm), soil water pipes (SWP Ø110mm), vent pipes (VP Ø50/110mm), floor drains, rodding eyes, vent cowls, and connections to the sewage collection sump. The plans detail the locations of bathroom fixtures including water closets, wash hand basins, urinals with partitions, and shower heads. The drawings provide specific pipe routing information including high-level and low-level installations, directions of flow, and connection points. The technical specifications are drawn to a 1:100 scale and include five detailed sections (A through E) showing both plan and elevation views of the plumbing system layout.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DIRECTION OF FLOW
VENT COWL
FLOOR DRAIN
WASH HAND BASIN
WATER CLOSET
RODDING EYE COVER (RE)
TYPICAL VENT PIPE (VP)Ø50/110mm
TYPICAL WASTE WATER PIPE (WWP)Ø50mm
TYPICAL SOIL WATER PIPE (SWP)Ø110mm
LEGEND
FLOOR CLEANOUT COVER
URINAL
URINAL PARTITION
VENT PIPE
SOIL WASTE PIPE
LOW LEVEL
VP
LL
SWP
WASTE WATER PIPESWP
HIGH LEVELHL
SHOWER HEAD
Ø50mm VP RISE
TO LL IN WALL
Ø110 VP FROM BELOW TO
HIGH LEVEL TO VENT
SEWAGE COLLECTION SUMP
Ø50mm VP@LL IN WALL
Ø50mm VP RISE TO HL IN WALL
TO CONNECT VENT COWL
Ø50mm WWP RUN ON
WALL OUTSIDE
Ø50mm SWP DROP
SEWER COLLECTION SUMP
CONTAINING SEWER TRANSFER PUMP
Ø50mm WWP RUN ON
WALL OUTSIDE
Ø50mm WWP IN SCREED
Ø110mm RODDING EYE@LL
IN WALL WITH CAP
Ø110mm RODDING EYE@LL
IN WALL WITH CAP
Ø50mm RODDING EYE
WITH CAP@LL
Ø50mm VP FB/ABOVE
WITH RODDING EYE
WITH CAP BELOW
Ø50mm WWP RUN
ON WALL OUTSIDE
Ø110mm RODDING EYE@LL
IN WALL WITH CAP
Ø110mm IN FLOOR SCREED
Ø110mm SWP@LL
Ø50mm VP RISE TO HL IN WALL
TYPICAL Ø50mm WWP IN
FLOOR SCREED
Ø50mm WWP@LL IN WALL
Ø50mm VP RISE LL/HL IN
WALL TO TERMINATE ON
WALL MOUNTED VENT COWL
TYPICAL Ø50mm WWP @LL
Ø50mm VP IN CEILING VOID
Ø50mm VP RISES TO HL IN
WALL
Ø50mm VP IN
CEILING VOID
Ø50mm VP RISE LL/HL IN
WALL TO TERMINATE ON
WALL MOUNTED VENT COWL
TYPICAL Ø50mm WWP IN
FLOOR SCREED
Ø50mm VP@LL IN WALL
Ø50mm VP RISE
TO HL IN WALL
Ø50mm VP RISE TO LL IN WALL
Ø50mm VP@LL IN WALL
Ø50mm RODDING
EYE WITH CAP
Ø50mm VP RISE
TO CEILING VOID
IN WALL
Ø50mm RUN IN
CEILING VOID
Ø110mm SWP@LL IN WALL
Ø110mm SWP DISCHARGE
TO SEWAGE COLLECTION
SUMP
Ø50mm WWP IN
FLOOR SCREED
Ø50mm WWP DROP TO
FLOOR SCREED
Ø50mm WWP DROP TO
FLOOR SCREED
Ø50mm WWP DROP TO
CONNECT PIPE @LL OUTSIDE
Ø50mm WWP DROP TO
CONNECT PIPE @LL OUTSIDE
Ø50mm WWP DROP TO
CONNECT WWP @LL OUTSIDE
Ø110mm WWP IN
FLOOR SCREED
Ø110mm SWP TO
CONNECT MANHOLE
Ø110mm SWP TO
CONNECT MANHOLE
Ø50mm RODDING
EYE WITH CAP
TYPICAL Ø50mm
RODDING EYE
WITH CAP
VENT COWL
Ø50mm VP@ LL IN WALL
TYPICAL Ø50mm
RODDING EYE WITH CAP
TYPICAL Ø50mm RODDING
EYE WITH CAP
Ø50mm RODDING EYE@LL IN
WALL WITH CAP
Ø110mm IN FLOOR SCREED
1:100
A
E
B
C
D
Ø50mm VP RISES TO HL IN
WALL
Ø50mm VP RISES TO HL IN
WALL
REV.NO. DATE DRWN
CHKD
DESIGNED BY:
DRAWN BY:
CROSS CHK'D BY:
APPROVED BY:
DATE:
SHEET CHK'D BY:
REMARKS
M .M
M.M
FA
SEPTEMBER 06, 2024
DRAINAGE LAYOUT
USAID ENGINEERING SUPPORT PROGRAM II:
EMBASSY COMPOUND
LOCAL GUARD FORCE (LGF) BATHROOM BUILDING
REFURBISHMENT WORKS
DRAWING NO.: M-101
PROJECT NO.
FILE NAME:
SCALE: NTS @A3
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1310 N Courthouse Rd, Ste 610 Arlington, VA 22201 Ph: +1 703 829 6133
GF
RF
12345678
Level 0
Level 1
SECTION B DETAIL
GF
RF
Level 0
SECTION A DETAIL
GF
RF
12345678
Level 0
Level 1
SECTION C DETAIL
GF
RF
Level 0
Level 1
SECTION D DETAIL
GF
RF
Level 0
Level 1
SECTION E DETAIL
REV.NO. DATE DRWN
CHKD
DESIGNED BY:
DRAWN BY:
CROSS CHK'D BY:
APPROVED BY:
DATE:
SHEET CHK'D BY:
REMARKS
M ,M
M.M
FA
SEPTEMBER 06, 2024
PLUMBING DETAILS
USAID ENGINEERING SUPPORT PROGRAM II:
EMBASSY COMPOUND
LOCAL GUARD FORCE (LGF) BATHROOM BUILDING
REFURBISHMENT WORKS
DRAWING NO.: M-102
PROJECT NO.
FILE NAME:
SCALE: NTS @A3
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1310 N Courthouse Rd, Ste 610 Arlington, VA 22201 Ph: +1 703 829 6133
| LGF BATHROOM BUILDING REFURBISHMENT_MECHANICAL DESIGN DRAWINGS _Rev 2-Layout1.pdf (p.1) |
| Layout1 |
| LGF BATHROOM BUILDING REFURBISHMENT_MECHANICAL DESIGN DRAWINGS _Rev 2-Layout2.pdf (p.2) |
| Layout1 |
File details come from the government source that posted it. Updated .