040126- JUNIPER (WLB 225A) R1 BLANK SOSS.xls
XLS spreadsheet 103 KB Posted
- Attached to
- USCGC JUNIPER (WLB-201) DRYDOCK REPAIR FY26
- Solicitation number
- 70Z08526QIBCT0026-Juniper
About this file
This is a Statement of Work and Cost Estimate Breakdown (SOS&S) for drydock availability and repair services for the USCGC Juniper (WLB-225A) during FY2026. The document outlines 93 definite line items and multiple option items covering comprehensive ship maintenance and repair work, including hull plating inspection and preservation, propulsion system overhaul, rudder and steering gear maintenance, tank cleaning and inspection, cathodic protection system maintenance, and various structural upgrades such as davit renewal, compass system upgrades, and watertight door renewal. The work is estimated to be performed at the contractor's facility with performance scheduled from approximately April 28, 2026, through August 26, 2026. The document includes a blank pricing template where unit prices and extended prices are to be filled in by the contractor; currently all line item prices are shown as $0.00. Labor cost breakdowns are structured by trade category (Engineer, Technician, Machinist/Pipe Fitter, Electrician, Shipfitter, Welder, Firewatch, Insulator/Lagger, Painter, General Labor/Helper/Rigger, and Supervisor/QA/NDT) with assumed overhead and profit factors of 15% and 10% respectively, and a composite labor rate of $55 per hour at the median rate across multiple geographic locations.
The solicitation is issued as a Request for Quotation (RFQ) under FAR Part 12 for Commercial Items and will result in an Indefinite Delivery Requirement (IDR) contract. This is a total small business set-aside with NAICS code 336611 (Ship Repair) and a small business size standard of 1,300 employees. The Coast Guard (Department of Homeland Security) will issue task orders to the selected contractor, with orders deliverable by mail, email, facsimile, or oral communication followed by written confirmation. Offerors must submit a cover letter with company information, the completed Attachment 1 pricing schedule, past performance documentation, small business self-certification, welding certifications and procedures, and proof of insurance. The cutter's home port is located at 400 Sand Island Parkway, Honolulu, HI 96819.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOS&S
| GOVERNMENT ESTIMATE FOR: | APM | ||||
| USCGC JUNIPER (WLB-225A) DRYDOCK AVAILABILITY FY2026 | Date Spec Due | ||||
| Date Est Due | |||||
| ITEM | DESCRIPTION | UNIT PRICE | UNIT | QTY | EXTENDED PRICE |
| D-001 | Fire Prevention Requirements | $0.00 | NSP | 1 | $0.00 |
| D-002 | Hull Plating, U/W Body, Inspect | $0.00 | JOB | 1 | $0.00 |
| D-003 | Hull Plating, U/W Body, Ultrasonic Testing | $0.00 | JOB | 1 | $0.00 |
| D-004 | Hull Plating, Freeboard, Ultrasonic Testing | $0.00 | JOB | 1 | $0.00 |
| O-005 | U/W Body, Preserve, 100 percent | $0.00 | JOB | 1 | $0.00 |
| D-006 | U/W Body, Preserve, Partial, Condition A | $0.00 | JOB | 1 | $0.00 |
| O-007 | U/W Body, Preserve, Partial, Condition B | $0.00 | JOB | 1 | $0.00 |
| O-008 | U/W Body, Preserve, Partial, Condition C | $0.00 | JOB | 1 | $0.00 |
| D-009 | Hull Plating Freeboard, Preserve, Partial | $0.00 | JOB | 1 | $0.00 |
| O-010 | Hull Plating Freeboard, Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| D-011 | Appendages, U/W, Leak Test | $0.00 | JOB | 1 | $0.00 |
| D-012 | Propulsion Shaft Fairwaters And Rope Guards, Inspect | $0.00 | JOB | 1 | $0.00 |
| D-013 | Appendages, U/W, Internal, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-014 | Chain Lockers, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-015 | Voids, Non-Accessible, Leak Test | $0.00 | JOB | 1 | $0.00 |
| D-016 | Voids, Non-Accessible, Internal Surfaces, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-017 | Tanks, Potable Water, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-018 | Tanks, Ballast, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-019 | Tanks, Dirty Oil and Waste, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-020 | Main Reduction Gear, Overhaul | $0.00 | JOB | 1 | $0.00 |
| D-021 | Propulsion Shafting; Remove, Inspect, and Reinstall | $0.00 | JOB | 1 | $0.00 |
| D-022 | Propulsion Shaft Seals, Mechanical Overhaul And Inflatable Renewal | $0.00 | JOB | 1 | $0.00 |
| D-023 | Propulsion Shaft Seals, Bulkhead, Overhaul | $0.00 | JOB | 1 | $0.00 |
| D-024 | Strain Gage Alignment, Check | $0.00 | JOB | 1 | $0.00 |
| O-025 | Propulsion Tail Shaft Sleeve, Skim Cut | $0.00 | JOB | 1 | $0.00 |
| D-026 | Propulsion Shaft Bearings, External, Check Clearances | $0.00 | JOB | 1 | $0.00 |
| O-027 | Propulsion Shaft Bearing, Stave Renewal | $0.00 | JOB | 1 | $0.00 |
| O-028 | Stern Tube Interior Surfaces, Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| D-029 | Controllable Pitch Propellers, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| O-030 | Controllable Pitch Propeller, System Maintenance, Perform | $0.00 | JOB | 1 | $0.00 |
| D-031 | Controllable Pitch Propeller Hub, General Maintenance with EAL, Perform | $0.00 | JOB | 1 | $0.00 |
| D-032 | Controllable Pitch Propeller Hub, Remove and Reinstall | $0.00 | JOB | 1 | $0.00 |
| D-033 | Heat Exchangers, Clean, Inspect And Hydro | $0.00 | JOB | 1 | $0.00 |
| D-034 | Ship Service Diesel Generator, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-035 | Emergency Diesel Generator, Clean & Inspect | $0.00 | JOB | 1 | $0.00 |
| D-036 | Fathometer Transducer, General Maintenance | $0.00 | JOB | 1 | $0.00 |
| D-037 | Sea Valves and Waster Pieces, Overhaul Or Renew | $0.00 | JOB | 1 | $0.00 |
| D-038 | Sea Strainers, Duplex, All Sizes, Overhaul | $0.00 | JOB | 1 | $0.00 |
| D-039 | Sea Strainers, Simplex, All Sizes, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-040 | Sea Bay, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-041 | Sea Bay, Preserve 100% | $0.00 | JOB | 1 | $0.00 |
| D-042 | Rudders, Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| D-043 | Rudder Stock Bearings, Check Clearances | $0.00 | JOB | 1 | $0.00 |
| D-044 | Rudder, Inspect And Repair | $0.00 | JOB | 1 | $0.00 |
| D-045 | Rudder and Rudder Stock, Remove and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-046 | Rudder Bearings, Renewal | $0.00 | JOB | 1 | $0.00 |
| D-047 | Thruster Units, Overhaul Fluid Change to EAL | $0.00 | JOB | 1 | $0.00 |
| D-048 | Thruster Generator, Clean & Inspect | $0.00 | JOB | 1 | $0.00 |
| D-049 | Anchor Windlass, Inspect and Service | $0.00 | JOB | 1 | $0.00 |
| D-050 | Anchor Chains and Ground Tackle, Inspect and Repair | $0.00 | JOB | 1 | $0.00 |
| D-051 | Anchor Chain and Ground Tackle, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-052 | Anchors, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-053 | Hawse Pipes, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-054 | Hull Fittings (Mooring and Towing), Inspect and Test | $0.00 | JOB | 1 | $0.00 |
| D-055 | Accessible Voids, Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| O-056 | Tanks, Ballast, Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| O-057 | Tanks, Ballast, Preserve, Partial | $0.00 | JOB | 1 | $0.00 |
| O-058 | Chain Locker, Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| O-059 | Chain Lockers, Preserve, Partial | $0.00 | JOB | 1 | $0.00 |
| D-060 | Accessible Void(s), Preserve, Partial, | $0.00 | JOB | 1 | $0.00 |
| O-061 | Tanks, Potable Water Preserve, 100 Percent | $0.00 | JOB | 1 | $0.00 |
| O-062 | Tanks, Potable Water, Preserve, Partial, | $0.00 | JOB | 1 | $0.00 |
| D-063 | Decks – Exterior (Buoy or Construction Deck), Preserve 100% | $0.00 | JOB | 1 | $0.00 |
| D-064 | Hull Plating Freeboard (Buoy Port Areas), Preserve | $0.00 | JOB | 1 | $0.00 |
| O-065 | Superstructure, Preserve, Partial | $0.00 | JOB | 1 | $0.00 |
| D-066 | Cathodic Protection, Zinc Anodes, Renew, | $0.00 | JOB | 1 | $0.00 |
| D-067 | Impressed Current Cathodic Protection System, Inspect and Maintain | $0.00 | JOB | 1 | $0.00 |
| D-068 | Impressed Current, Cathodic Protection System, Reference Cells, Renew | $0.00 | JOB | 1 | $0.00 |
| D-069 | Drydock | $0.00 | JOB | 1 | $0.00 |
| D-070 | Temporary Services, Provide - Cutter | $0.00 | JOB | 1 | $0.00 |
| D-071 | Sea Trial Performance, Support, Provide | $0.00 | JOB | 1 | $0.00 |
| D-072 | ATON Tie Down Installation | $0.00 | JOB | 1 | $0.00 |
| D-073 | Compartment Insulation, General, Renew | $0.00 | JOB | 1 | $0.00 |
| D-074 | Firemain Valves, Overhaul or Renew | $0.00 | JOB | 1 | $0.00 |
| D-075 | Space or Component, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-076 | Welin Lambie Dual Point Davit TWPIV 5.0B, Renew | $0.00 | JOB | 1 | $0.00 |
| D-077 | ATON Tie-down Install | $0.00 | JOB | 1 | $0.00 |
| D-078 | Anchor Tripping Bracket Install | $0.00 | JOB | 1 | $0.00 |
| D-079 | Fluxgate Digital Compass System, Upgrade | $0.00 | JOB | 1 | $0.00 |
| D-080 | Pilothouse Exterior Safety Rail, Renew | $0.00 | JOB | 1 | $0.00 |
| D-081 | Forecastle Raised Hatch, Renew | $0.00 | JOB | 1 | $0.00 |
| D-082 | Buoy Deck Quick Acting Watertight Door, Renew | $0.00 | JOB | 1 | $0.00 |
| D-083 | Air Escape (AE) Piping, Renew | $0.00 | JOB | 1 | $0.00 |
| D-084 | Weathertight Doors, Renew | $0.00 | JOB | 1 | $0.00 |
| D-085 | Directional Control Valve, Upgrade | $0.00 | JOB | 1 | $0.00 |
| D-086 | Pilot House Windows and Frame, Repair and Reseal | $0.00 | JOB | 1 | $0.00 |
| D-087 | Tanks, MP Fuel Stowage and Overflow, Clean and Inspect | $0.00 | JOB | 1 | $0.00 |
| D-088 | Decks - Exterior, Preserve, Non-Skid Broadcast Grit System | $0.00 | JOB | 1 | $0.00 |
| D-089 | Potable Water Pump Room Deck, Preserve | $0.00 | JOB | 1 | $0.00 |
| D-090 | Steering Gear Heat Exchanger, Modify | $0.00 | JOB | 1 | $0.00 |
| D-091 | Steering System PLC, Upgrade | $0.00 | JOB | 1 | $0.00 |
| D-092 | Buoy Deck Incline Ladders, Renew | $0.00 | JOB | 1 | $0.00 |
| D-093 | Tenting, Provide | $0.00 | NSP | 1 | $0.00 |
| D-094 | Independent NACE Inspector (Level 3), Provide | $0.00 | NSP | 1 | $0.00 |
| O-00A | Composite Labor Rate | 0 | Hour | 500 | 0 |
| D-00C | Travel and Perdiem | $500.00 | JOB | $0.00 | |
| O-00Z | Laydays | $0.00 | Day | 5 | $0.00 |
| Total Price of Definite Items | $0.00 | ||||
| Total Price of Option Items | $0.00 | ||||
| Total Price of Definite and Optional Items | $0.00 |
&C(7/9/2025) Rev-0 - Page &P of &N
CostEstimateBreakdowns
| Composite Labor Rate | 55 | |||||||||||||||||||||||
| Assumed G&A Factor | 15% | |||||||||||||||||||||||
| Assumed Profit Factor | 10% | Direct Labor | Direct Material/Subs Cost | |||||||||||||||||||||
| ITEM | DESCRIPTION | UNIT PRICE | Sub-Contracted (put a "1" in the blank) | Total Labor Hours | Total Material & Subs (cost + G&A + profit) | Eng Tech | Machinest/Pipe Fitter | Electrician | Shipfitter | Welder | Firewatch | Insulator/Lagger | Painter | Gen Labor/Helper/Rigger | Supt/QA/NDT | Mat/Sub Cost 1 | Mat/Sub Cost 2 | Mat/Sub Cost 3 | Mat/Sub Cost 4 | Lab Rate | Area | WorkItemID | WIFileID | LoadData |
| D-001 | Fire Prevention Requirements TYPE | $ - 0 | 0 | 0 | 62 | Baltimore, MD | 11293 | 1 | 93 | |||||||||||||||
| D-002 | Hull Plating, U/W Body, Inspect | $ - 0 | 0 | 0 | 52 | Biloxi, MS | 5089 | 1 | 20 | |||||||||||||||
| D-003 | Hull Plating, U/W Body, Ultrasonic Testing | $ - 0 | 0 | 0 | 56 | Boston, MA | 23 | 1 | WLB 225A | |||||||||||||||
| D-004 | Hull Plating, Freeboard, Ultrasonic Testing | $ - 0 | 0 | 0 | 50 | Charleston, SC | 3999 | 1 | 0 | |||||||||||||||
| D-005 | U/W Body, Preserve, 100 percent | $ - 0 | 0 | 0 | 60 | Corpus Christi, TX | 1705 | 1 | 16 | |||||||||||||||
| D-006 | U/W Body, Preserve, Partial, Condition A | $ - 0 | 0 | 0 | 51 | Hampton Roads | 522 | 1 | 125 | |||||||||||||||
| D-007 | U/W Body, Preserve, Partial, Condition B | $ - 0 | 0 | 0 | 64 | Honolulu, HI | 523 | 1 | FY2026 | |||||||||||||||
| D-008 | U/W Body, Preserve, Partial, Condition C | $ - 0 | 0 | 0 | 55 | Houston, TX | 524 | 1 | DD | |||||||||||||||
| D-009 | Hull Plating Freeboard, Preserve, Partial | $ - 0 | 0 | 0 | 56 | Los Angeles, CA | 5236 | 1 | cutter | |||||||||||||||
| D-010 | Hull Plating Freeboard, Preserve, 100 Percent | $ - 0 | 0 | 0 | 55 | Median Rate | 5404 | 1 | JUNIPER (WLB 225A) DD FQ2 KAH 26R0.doc | |||||||||||||||
| D-011 | Appendages, U/W, Leak Test | $ - 0 | 0 | 0 | 49 | Miami | 5158 | 1 | ||||||||||||||||
| D-012 | Propulsion Shaft Fairwaters And Rope Guards, Inspect | $ - 0 | 0 | 0 | 50 | Narragansett Bay, RI | 5405 | 1 | ||||||||||||||||
| D-013 | Appendages, U/W, Internal, Preserve | $ - 0 | 0 | 0 | 55 | New London, CN | 42 | 1 | ||||||||||||||||
| D-014 | Chain Lockers, Clean and Inspect | $ - 0 | 0 | 0 | 45 | New Orleans | 46 | 1 | ||||||||||||||||
| D-015 | Voids, Non-Accessible, Leak Test | $ - 0 | 0 | 0 | 62 | NYNY | 54 | 1 | ||||||||||||||||
| D-016 | Voids, Non-Accessible, Internal Surfaces, Preserve | $ - 0 | 0 | 0 | 49 | Panama City, FL | 67 | 1 | ||||||||||||||||
| D-017 | Tanks, Potable Water, Clean and Inspect | $ - 0 | 0 | 0 | 60 | Philadelphia, PA | 75 | 1 | ||||||||||||||||
| D-018 | Tanks, Ballast, Clean and Inspect | $ - 0 | 0 | 0 | 51 | Portland, ME | 3996 | 1 | ||||||||||||||||
| D-019 | Tanks, Dirty Oil and Waste, Clean and Inspect | $ - 0 | 0 | 0 | 57 | Portland, OR | 81 | 1 | ||||||||||||||||
| D-020 | Main Reduction Gear, Overhaul | $ - 0 | 0 | 0 | 55 | San Diego, CA | 10757 | 1 | ||||||||||||||||
| D-021 | Propulsion Shafting; Remove, Inspect, and Reinstall | $ - 0 | 0 | 0 | 67 | San Francisco, CA | 5195 | 1 | ||||||||||||||||
| D-022 | Propulsion Shaft Seals, Mechanical Overhaul And Inflatable Renewal | $ - 0 | 0 | 0 | 55 | Santa Barbara, CA | 9679 | 1 | ||||||||||||||||
| D-023 | Propulsion Shaft Seals, Bulkhead, Overhaul | $ - 0 | 0 | 0 | 55 | SE North Carolina | 175 | 1 | ||||||||||||||||
| D-024 | Strain Gage Alignment, Check | $ - 0 | 0 | 0 | 65 | Seattle, WA | 9707 | 1 | ||||||||||||||||
| D-025 | Propulsion Tail Shaft Sleeve, Skim Cut | $ - 0 | 0 | 0 | 48 | Tampa-St. Petersburg | 201 | 1 | ||||||||||||||||
| D-026 | Propulsion Shaft Bearings, External, Check Clearances | $ - 0 | 0 | 0 | 60 | Wilmington, DE | 10773 | 1 | ||||||||||||||||
| D-027 | Propulsion Shaft Bearing, Stave Renewal | $ - 0 | 0 | 0 | 11139 | 1 | ||||||||||||||||||
| D-028 | Stern Tube Interior Surfaces, Preserve, 100 Percent | $ - 0 | 0 | 0 | 526 | 1 | ||||||||||||||||||
| D-029 | Controllable Pitch Propellers, Clean and Inspect | $ - 0 | 0 | 0 | 8500 | 1 | ||||||||||||||||||
| D-030 | Controllable Pitch Propeller Hub, General Maintenance with EAL, Perform | $ - 0 | 0 | 0 | 10678 | 1 | ||||||||||||||||||
| D-031 | Controllable Pitch Propeller Hub, Remove and Reinstall | $ - 0 | 0 | 0 | 1076 | 1 | ||||||||||||||||||
| D-032 | Heat Exchangers, Clean, Inspect And Hydro | $ - 0 | 0 | 0 | 245 | 1 | ||||||||||||||||||
| D-033 | Ship Service Diesel Generator, Clean and Inspect | $ - 0 | 0 | 0 | 274 | 1 | ||||||||||||||||||
| D-034 | Emergency Diesel Generator, Clean & Inspect | $ - 0 | 0 | 0 | 799 | 1 | ||||||||||||||||||
| D-035 | Fathometer Transducer, General Maintenance | $ - 0 | 0 | 0 | 10101 | 1 | ||||||||||||||||||
| D-036 | Sea Valves and Waster Pieces, Overhaul Or Renew | $ - 0 | 0 | 0 | 2065 | 1 | ||||||||||||||||||
| D-037 | Sea Strainers, Duplex, All Sizes, Overhaul | $ - 0 | 0 | 0 | 314 | 1 | ||||||||||||||||||
| D-038 | Sea Strainers, Simplex, All Sizes, Clean and Inspect | $ - 0 | 0 | 0 | 315 | 1 | ||||||||||||||||||
| D-039 | Sea Bay, Clean and Inspect | $ - 0 | 0 | 0 | 2774 | 1 | ||||||||||||||||||
| D-040 | Sea Bay, Preserve 100% | $ - 0 | 0 | 0 | 2775 | 1 | ||||||||||||||||||
| D-041 | Rudders, Preserve, 100 Percent | $ - 0 | 0 | 0 | 1869 | 1 | ||||||||||||||||||
| D-042 | Rudder Stock Bearings, Check Clearances | $ - 0 | 0 | 0 | 1242 | 1 | ||||||||||||||||||
| D-043 | Rudder, Inspect And Repair | $ - 0 | 0 | 0 | 1244 | 1 | ||||||||||||||||||
| D-044 | Rudder and Rudder Stock, Remove and Inspect | $ - 0 | 0 | 0 | 6680 | 1 | ||||||||||||||||||
| D-045 | Rudder Bearings, Renewal | $ - 0 | 0 | 0 | 1248 | 1 | ||||||||||||||||||
| D-046 | Thruster Units, Overhaul Fluid Change to EAL | $ - 0 | 0 | 0 | 10816 | 1 | ||||||||||||||||||
| D-047 | Thruster Generator, Clean & Inspect | $ - 0 | 0 | 0 | 11190 | 1 | ||||||||||||||||||
| D-048 | Anchor Windlass, Inspect and Service | $ - 0 | 0 | 0 | 7707 | 1 | ||||||||||||||||||
| D-049 | Anchor Chains and Ground Tackle, Inspect and Repair | $ - 0 | 0 | 0 | 718 | 1 | ||||||||||||||||||
| D-050 | Anchor Chain and Ground Tackle, Preserve | $ - 0 | 0 | 0 | 1787 | 1 | ||||||||||||||||||
| D-051 | Anchors, Preserve | $ - 0 | 0 | 0 | 1394 | 1 | ||||||||||||||||||
| D-052 | Hawse Pipes, Preserve | $ - 0 | 0 | 0 | 1890 | 1 | ||||||||||||||||||
| D-053 | Hull Fittings (Mooring and Towing), Inspect and Test | $ - 0 | 0 | 0 | 6604 | 1 | ||||||||||||||||||
| D-054 | Accessible Voids, Preserve, 100 Percent | $ - 0 | 0 | 0 | 3985 | 1 | ||||||||||||||||||
| D-055 | Tanks, Ballast, Preserve, 100 Percent | $ - 0 | 0 | 0 | 5108 | 1 | ||||||||||||||||||
| D-056 | Tanks, Ballast, Preserve, Partial | $ - 0 | 0 | 0 | 489 | 1 | ||||||||||||||||||
| D-057 | Chain Locker, Preserve, 100 Percent | $ - 0 | 0 | 0 | 2416 | 1 | ||||||||||||||||||
| D-058 | Chain Lockers, Preserve, Partial | $ - 0 | 0 | 0 | 491 | 1 | ||||||||||||||||||
| D-059 | Accessible Void(s), Preserve, Partial, | $ - 0 | 0 | 0 | 505 | 1 | ||||||||||||||||||
| D-060 | Tanks, Potable Water Preserve, 100 Percent | $ - 0 | 0 | 0 | 2877 | 1 | ||||||||||||||||||
| D-061 | Tanks, Potable Water, Preserve, Partial, | $ - 0 | 0 | 0 | 499 | 1 | ||||||||||||||||||
| D-062 | Decks – Exterior (Buoy or Construction Deck), Preserve 100% | $ - 0 | 0 | 0 | 2865 | 1 | ||||||||||||||||||
| D-063 | Hull Plating Freeboard (Buoy Port Areas), Preserve | $ - 0 | 0 | 0 | 5295 | 1 | ||||||||||||||||||
| D-064 | Superstructure, Preserve, Partial | $ - 0 | 0 | 0 | 5045 | 1 | ||||||||||||||||||
| D-065 | Cathodic Protection, Zinc Anodes, Renew, | $ - 0 | 0 | 0 | 542 | 1 | ||||||||||||||||||
| D-066 | Impressed Current Cathodic Protection System, Inspect and Maintain | $ - 0 | 0 | 0 | 2181 | 1 | ||||||||||||||||||
| D-067 | Impressed Current, Cathodic Protection System, Reference Cells, Renew | $ - 0 | 0 | 0 | 1648 | 1 | ||||||||||||||||||
| D-068 | Drydock | $ 149,250.00 | 1600 | 61250 | $1,600.00 | $49,000.00 | 555 | 1 | ||||||||||||||||
| D-069 | Temporary Services, Provide - Cutter | $ - 0 | 0 | 0 | 556 | 1 | ||||||||||||||||||
| D-070 | Sea Trial Performance, Support, Provide | $ - 0 | 0 | 0 | 563 | 1 | ||||||||||||||||||
| D-071 | ATON Tie Down Installation | $ - 0 | 0 | 0 | 11129 | 1 | ||||||||||||||||||
| D-072 | Compartment Insulation, General, Renew | $ - 0 | 0 | 0 | 688 | 1 | ||||||||||||||||||
| D-073 | Firemain Valves, Overhaul or Renew | $ - 0 | 0 | 0 | 669 | 1 | ||||||||||||||||||
| D-074 | Space or Component, Preserve | $ - 0 | 0 | 0 | 684 | 24 | ||||||||||||||||||
| D-075 | Welin Lambie Dual Point Davit TWPIV 5.0B, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-076 | ATON Tie-down Install | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-077 | Anchor Tripping Bracket Install | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-078 | Fluxgate Digital Compass System, Upgrade | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-079 | Pilothouse Exterior Safety Rail, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-080 | Forecastle Raised Hatch, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-081 | Buoy Deck Quick Acting Watertight Door, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-082 | Air Escape (AE) Piping, Renew | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-083 | Weathertight Doors, Renew (2) | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-084 | Directional Control Valve, Upgrade | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-085 | Pilot House Windows and Frame, Repair and Reseal | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-086 | Tanks, MP Fuel Stowage and Overflow, Clean and Inspect | $ - 0 | 0 | 0 | 51 | 1 | ||||||||||||||||||
| D-087 | Decks - Exterior, Preserve, Non-Skid Broadcast Grit System | $ - 0 | 0 | 0 | 4000 | 1 | ||||||||||||||||||
| D-088 | Potable Water Pump Room Deck, Preserve | $ - 0 | 0 | 0 | 2561 | 1 | ||||||||||||||||||
| D-089 | Steering Gear Heat Exchanger, Modify | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-090 | Steering System PLC, Upgrade | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-091 | Tenting, Provide | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-092 | Independent NACE Inspector (Level 3), Provide | $ - 0 | 0 | 0 | 10000 | 0 | ||||||||||||||||||
| D-093 | Buoy Deck Incline Ladders, Renew | $ - 0 | 0 | 0 | 10000 | 0 |
&C(09/28/2009) Page &P of &N
CostEstimateTemplate
| Composite Labor Rate | 55 | ||||||||||||||||
| Assumed G&A Factor | 15% | ||||||||||||||||
| Assumed Profit Factor | 10% | Direct Labor | Direct Material/Subs Cost | ||||||||||||||
| Sub-Contracted (put a "1" in the blank) | Total Labor Hours | Total Material & Subs (cost + G&A + profit) | Eng Tech | Machinest/Pipe Fitter | Electrician | Shipfitter | Welder | Firewatch | Insulator/Lagger | Painter | Gen Labor/Helper/Rigger | Supt/QA/NDT | |||||
| DESCRIPTION | UNIT PRICE | Lab Rate | Area | ||||||||||||||
| $0 | 0 | $0 | 62 | Baltimore, MD | |||||||||||||
| $0 | 0 | $0 | 52 | Biloxi, MS | |||||||||||||
| $0 | 0 | $0 | 56 | Boston, MA | |||||||||||||
| $0 | 0 | $0 | 50 | Charleston, SC | |||||||||||||
| $0 | 0 | $0 | 60 | Corpus Christi, TX | |||||||||||||
| $0 | 0 | $0 | 64 | Honolulu, HI | |||||||||||||
| $0 | 0 | $0 | 55 | Houston, TX | |||||||||||||
| $0 | 0 | $0 | 56 | Los Angeles, CA | |||||||||||||
| $0 | 0 | $0 | 55 | Median Rate | |||||||||||||
| $0 | 0 | $0 | 55 | Median Rate | |||||||||||||
| $0 | 0 | $0 | 50 | Narragansett Bay, RI | |||||||||||||
| 55 | New London, CN | ||||||||||||||||
| 45 | New Orleans | ||||||||||||||||
| 62 | NYNY | ||||||||||||||||
| 49 | Panama City, FL | ||||||||||||||||
| 60 | Philadelphia, PA | ||||||||||||||||
| 51 | Portland, ME | ||||||||||||||||
| 57 | Portland, OR | ||||||||||||||||
| 55 | San Diego, CA | ||||||||||||||||
| 67 | San Francisco, CA | ||||||||||||||||
| 55 | Santa Barbara, CA | ||||||||||||||||
| 55 | SE North Carolina | ||||||||||||||||
| 65 | Seattle, WA | ||||||||||||||||
| 48 | Tampa-St. Petersburg | ||||||||||||||||
| 60 | Wilmington, DE |