Amendment 0004(Final).pdf
PDF 642 KB Posted
- Solicitation number
- 70Z08520RP45A5400
About this file
This combined synopsis/solicitation requests proposals for dockside repairs of the USCGC MUNRO (WMSL 755). The Coast Guard seeks repairs including items specified in Attachment 1 such as ship repair and support work. Offerors should complete Attachment 2 with unit pricing for base and optional CLINs. Proposals are due by July 29, 2020 with award anticipated on August 14, 2020. The period of performance is September 14 through November 13, 2020. This is a total small business set-aside for NAICS code 336611 with a size standard of 1250 employees. The contract will be fixed price awarded to the responsive, responsible offeror. Drawings may be requested by completing the non-disclosure agreement in Attachment 6. Questions are due by July 21, 2020 with responses provided via amendment. Proposals must include the information specified in Attachment 3 such as the offeror's address, completed price schedule, and technical capability proposal.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applible)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
2. AMENDMENT/MODIFICATION NUMBER
Wilma Estrada, Contracting Officer
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
SUBJECT: RFP No. 70Z08520RP45A5400 USCGC MUNRO (WMSL-755)
SEE PAGES 2-6 FOR DESCRIPTION
USCG, Commander Surface Forces Logistics Center, LRE-C&PD2 1301 Clay Street, Suite 800N Oakland, CA 94612
TO ALL PROSPECTIVE OFFERORS
Same as Block 6
2120850P45A54
70Z80520RP45A5400
1 6
07/24/2020
30 June 2020
70Z08520RP45A5400
USCGC MUNRO ( WMSL 755 ) DOCKSIDE REPAIRS FQ4 FY20
Amendment No. 0004
The purpose of this amendment is to:
1. Reply to the following Requests for Clarifications:
QUESTION 1: Definite item No: WI04, Title: Flex Hose Assemblies (Main Gas Turbine), Renew,PARA No: 3.3
Hose renewal, Table, No #03. Q1) In WI 04, Table # 03 identifies the list of 66 hoses that are to be renewed on the
GT. The list provides no details as to hose length and fittings. After reviewing the identified reference drawings, we have only been able to identify the details on 16 hoses. Can the CG provide better details on the other 50 hoses that are not detailed in the referenced drawings? Also, drawing 750-WMSL-505-006, Rev D, List Of Hoses has the following pages blank with no details, page # 14, 15, 16, 21, 22, 23, was this intentional? We did find a reference to
GE drawing 5376166, is this available?
RESPONSE TO QUESTION 1:
The CG acknowledges drawing 750-WMSL-505-006, Rev D, List Of Hoses is incomplete, leaves pages blank and is often revised.
Specific details for USCGC MUNRO have not been confirmed since shipyard installation. Any disparities between the below list and what is on USCGC MUNRO should be addressed when completing paragraph 3.3.1 Hose inspection and verification of the specification and/or via CFR.
Please see the revised Table 3 with additional lengths noted from USCGC STRATTON.
TABLE 3 - GAS TURBINE (COMPARTMENT: 5-44-01-E)
HOSE
SERIAL #
LENGTH
(IN.)
SIZE
(IN.)
PART
NUMBER NSN FITTING #1 FITTING #2
DESIGN
PRESS
(PSI)
GTBA-HOSE-
C21682-
GTLOS-F-001
24 C21682-
GTFS-F-005
AE
2580-32
GTFS-F-006
2580-32
73.5
GTFS-F-007
2580-24
GTFS-F-008
2580-24
GTLOS-F-002
C21682-
ALPV-F-020
HS
C21682
Amendment No. 0004
SERIAL #
LENGTH
(IN.)
SIZE
(IN.)
PART
NUMBER NSN FITTING #1 FITTING #2
DESIGN
PRESS
(PSI)
GT-A-001
33 C21682-
GT-A-003
18 HS
C21682
GTH-F-001
C21686
GTH-F-003
C21685
GTH-F-004
C21688
GTH-F-005
C21687
GT-HYD-005
GTH-F-
(GT-
HYD-
003)
GT-HYD-006
GTH-F-
(GT-
004)
GT-HYD-007
GTH-F-
(GT-
002)
GT-HYD-008
GTH-F-
(GT-
001)
GT-HYD-009
3/8"
GT-HYD-010
GT-HYD-011
GT-HYD-012
GT-HYD-013
LENGTH
(IN.)
SIZE
(IN.)
PART
NUMBER NSN FITTING #1 FITTING #2
DESIGN
PRESS
(PSI)
GT-HYD-014
GT-HYD-015
GT-HYD-016
GT-HYD-017
14.7
GTOW-H-001
D21912-
GTOW-H-003
GTOW-H-002
GTOW-H-004
GT-FO-001
2"
GT-FO-002
1/2"
GT-FO-003
GT-FO-004
GT-FO-005
GT-F0-006
(GTFS-F-004)
3013-
DSL-
752646
GT-FO-009
GT-FO-010
GT-F0-011
GT-FO-012
5/8"
LENGTH
(IN.)
SIZE
(IN.)
PART
NUMBER NSN FITTING #1 FITTING #2
DESIGN
PRESS
(PSI)
GT-FO-013
GT-FO-014
3/4"
GTFS-F-001
C21683-
GTFS-F-002
C21683-
GT-LO-001
5/16"
GT-LO-002
5/16"
GT-LO-003
1"
GT-LO-004
GT-LO-005
GT-LO-006
GT-LO-007
GT-LO-008
GT-LO-009
GT-LO-010
GT-LO-011
GT-LO-012
GT-LO-013
GT-LO-014
LENGTH
(IN.)
SIZE
(IN.)
PART
NUMBER NSN FITTING #1 FITTING #2
DESIGN
PRESS
(PSI)
GT-LO-015
GT-LO-016
GT-LO-017
GT-LO-018
GT-LO-021
GT-W-001
33 C-
21682-5
GT-WW-002
QUESTION 2: Definite item No: WI-006, Title: Refrigeration Plant System Groom, PARA No: A0003
Q1) Based on the CG Answer in Amendment 00003, OEM is requesting authorization to use Electronic Leak
Detectors.
Para 3.4.17.1 The contractor shall conduct a refrigerant leak test in the presence of Coast Guard Inspector in accordance with the instructions in Paragraph 5.1, “Leak Testing,” Section 10 of TP 7168. Check every joint with a soapsuds solution mentioned in “LEAK TEST OF SYSTEM,” Section 19 of TP 7168. Electronic leak detectors are not acceptable. Submit a CFR.
RESPONSE TO QUESTION 2: Leak testing to be performed with soapsuds solutions. Electronic leak detectors are not acceptable.
QUESTION 3: Definite Item No: WI-028, Title: Prototype APFF Piping, Modify, PARA No.
3.2.2: Para 3.2.2 on WI#28 calls out to install new AFFF piping IAW 418A-WMSL-555, Sheets
003 through 7. Reference is not provided, need reference in order to price material requirements.
RESPONSE TO QUESTION 3: Drawing 418A-WMSL-555 will be sent via DOD Safe site to all prospective offerors who have already requested copies of drawings.