Amendment 0001 page 2 - MUNRO DS FQ4 FY20.pdf
PDF 148 KB Posted
- Solicitation number
- 70Z08520RP45A5400
About this file
This combined synopsis/solicitation seeks proposals for dock-side repairs to the USCGC Munro (WMSL 755). Required work includes ship repair and associated support in accordance with the attached specification. Proposals are due by July 29, 2020 with award expected on or around August 14, 2020. The performance period is September 14 through November 13, 2020. The solicitation is a total small business set-aside under NAICS code 336611. Offerors must provide pricing for all contract line items in the schedule of supplies and services. Technical capability and past performance are of equal importance and more significant than price in the evaluation. Questions are due by July 21, 2020.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
70Z08520RP45A5400
USCGC MUNRO ( WMSL 755 ) DOCKSIDE REPAIRS FQ4 FY20
Amendment No. 0001
The purpose of this amendment is to:
1. To remove the gray bar on the right hand side of the SPEC to a more readable version ( see revised
Attachment 1 ).
2. To remove the following sentences on page 2 of the Combined Synopsis notice ( see revised
Combined Synopsis notice ).
Removed:
*** The period of performance may change upon award of the contract. Funds are not currently Available. No award will be made until funds are available***
3. To update the following statement in revision Attachment 3, page 28 of 46 as follows ( see revised
Attachment 3 ):
From:
*** Technical capability and Past Performance are equal in importance and are significantly more important than Price. If technical capability and past performance evaluations of offers result in equal ratings, price will become a determinative factor in the Best Value Decision**** To:
***Technical Capability and Past Performance are equal in importance to each other. Both Technical Capability and Past Performance are significantly more important than price. If technical capability and past performance evaluations of offers result in equal ratings, price may become a determinative factor in the Best Value Decision.***
4. Reply to the following Requests for Clarification:
QUESTION 1: Definite item No: D‐10, 3.1.6, 3.2, 3.1.6, Table 2, The Contractor shall furnish and install parts listed in the Table 2: 1ea, 71042, Wire Rope Assembly with Off Load Hook. 3.2 Biannual maintenance inspection and repair task particulars. Table 3.
The Allied Duel Point Davit System is equipped with (2) Wire Rope Assemblies. The specifications call’s two renew (2) wire rope assemblies and for the contractor to provide only (1). Is the government providing the second wire rope assembly?
The contractor recommends the Allied parts/materials be supplied as Government Furnished Equipment as they have long lead times and may delay or extend the contract.
RESPONSE TO QUESTION 1:
Government Response: Both wire ropes shall be provided by the KTR as Contract-Furnished Equipment.
Government is fully aware and understands the risks. The specification will be revised to read as such: [please note the addition of the off load hooks as a separate line items and increase in quantity for the Wire Ropes]
3.1.6. Materials. The Contractor shall furnish and install parts listed in Table 2 – List of Parts
70Z08520RP45A5400
USCGC MUNRO ( WMSL 755 ) DOCKSIDE REPAIRS FQ4 FY20
Amendment No. 0001
Table 2 – LIST OF PARTS
QUESTION 2: Definite item No: D‐10, Allied Marine Maintenance Intervals, Replace Hydraulic Hoses, Paragraph 6.5.8.2. Will the Contractor be required to renew, replace or hydrotest the hoses on the davit assemble as part of the work scope?
RESPONSE TO QUESTION 2:
GOVERNMENT RESPONSE: The Govt is not looking to have the hydraulic hoses replaced during this period, however KTR is still required to conduct an inspection of hoses and submit documentation. The specification will be revised to remove ‘Replace Hydraulic Hoses, Paragraph 6.5.8.2 from the Allied Maintenance Intervals [page 83] and also to include the below paragraph.
3.X Flexible Hoses. Inspect system flex hoses. Submit CFR noting service and hydrostatic testing dates. CFR shall include all discrepancies with recommended corrective actions.
QUANTITY PART NUMBER DESCRIPTION SOURCES OF SUPPLY
1 70125 / 941041Q Pressure Filter: Replacement Filters Allied System Co.
214 S.W. Oregon Street Sherwood, OR 97140
1 70124 / 941032Q Pressure Filter: Replacement Filters 2 71042 *Wire Rope Assembly 2 70195 / 937833Q Return Filters 2 74130/ 2049010005 Return Filter Seal Kit 2 70439 *Off Load Hooks
File details come from the government source that posted it. Updated .