This document contains a federal contract opportunity and related technical file. The federal contract opportunity is a solicitation from the Department of Homeland Security United States Coast Guard for design-build services to upgrade mooring and structural piers at the US Coast Guard Base in Honolulu, Hawaii. The scope of work includes demolishing an existing floating pier, constructing a fixed pier extension to berth a 225-foot seagoing buoy tender, providing a shore tie mound, and optional items to construct a floating pier to berth a 154-foot fast response cutter and a pier extension between an existing bulkhead and new wharf. The technical file describes the existing telecommunications infrastructure at the Coast Guard base, including copper and fiber optic cabling, telecom cabinets, splices, and related equipment.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRITCHARD ST.
EMH
EMH
SFM4
FH
PAR SHOP
FH-3
M A
G A
Z
IN
E
LP FH-2
LP
CMH
S O H
W12
T R
A
IL
E R
X
MSST
ADMIN
BLDG
TRAILER
56 X 12TRAILER
56 X 12
TRAILER
56 X 12 STORAGE
BUILDING
SD48
UNPAVED
AREA
2-4in Crushed conduit
EDGE OF
PAVEMENT
110'
LP
LP
LP
200' 0
EMH
CMH
EMH
EMH
HEALY AVE.
225'
CMH
CMH
EMH
JAMES AVE.
LP
EMH
SS4
DOG HOUSE #2
(w14)
378'
NOTE:
WHARF DIMENSIONS ARE
APPROXIMATE. SEE WHARF
LOADING DRAWINGS FOR ACTUAL
DIMENSIONS.
200' 400'
CMH
EMH
DOG HOUSE #1
(w15)
POWER MOUND #2
arm ory
ESU
WPB telephone room. incoming 50pr from ISC demarc feeds WPB bldg, 110 pier, 87' Ahi pier.
equipment room. terminates 200pr from Galley pedestal. distributes dial tones to Galley and clinic via 25 and/or 50pr
200pair splice feeds Armory, PAR, with extra pairs leftover for range
25pair. side A: 1200pr splice NW corner of ESU bldg. Side B:Club14 telephone room.****Installed 2005****
25pair. side A: 1200pr splice NW corner of ESU bldg. Side B:Club14 telephone room.****Installed 2005****
25pair. side A: 1200pr splice NW corner of ESU bldg. Side B:Club14 telephone room.****Installed 2005****
Contains 1200pr to 1200pr stright thru splice.
main trailer feed to adjacent trailers
50pair 24awg telecom cable installed 2005
50pair 24awg telecom cable installed 2005
50pair 24awg telecom cable installed 2005
25 pair 24 awg copper cable from WPB demarc to 110 power mound. Installed 2006
25 pair copper 24awg WPB demarc to Ahi pier shore tie box
25 pair copper 24awg WPB demarc to Ahi pier shore tie box. Installed 2005
25 pair copper 24awg WPB demarc to Ahi pier shore tie box
100pr from bldg 645 to ESU 1st deck TC. 3 PRI's for PBX ride on this cable***Installed 2005***
25pair. side A: 1200pr splice NW corner of ESU bldg. Side B:Club14 telephone room.****Installed 2005****
100pr from bldg 645 to ESU 1st deck TC. 3 PRI's for PBX ride on this cable***Installed 2005***
25 pair copper 24awg WPB demarc to Ahi pier shore tie box
25 pair copper 24awg WPB demarc to Ahi pier shore tie box
25 pair 24 awg copper cable from WPB demarc to 110 power mound.
25 pair 24 awg copper cable from WPB demarc to 110 power mound.
right click to view MH diagram
3M 4950 telecom cabinet with 3m MS2 connectors
1200 pair splice.***INSTALLED 2005***. prs 1-1150 spliced to Galley 2700pr pedestal. Prs 1151-1175 spliced onto 25prs to Gym TR. Prs 1176-1200 are spliced to Club 14 TR.
outdoor cat5 feeds from northern trailer to small telcom cabinets in each adjacent trailer.
outdoor cat5 feeds from northern trailer to small telcom cabinets in each adjacent trailer.
outdoor cat5 feeds from northern trailer to small telcom cabinets in each adjacent trailer.
outdoor cat5 feeds from northern trailer to small telcom cabinets in each adjacent trailer.
100pr from bldg 645 to ESU 1st deck TC. 3 PRI's for PBX ride on this cable***Installed 2005***
200pr pier feed. terminates to indoor splice in MDF than to Lightning protection blocks. ****installed 2005*** two 600pr 24awg cable from MDF to ESU 1st deck TR. Feeds PBX dial tones back to MDF for distribution around base,***installed 2005****
1200pr feed from MDF to 1200par splice in maint.hole at NW corner of ESU bldg. Feeds Galley telecom cabinet which feeds everything west of ESU bldg. Station, MSST,Galley,Clinic,armory etc.***OLD.NEEDS REPLACING***
25pair. side A: 1200pr splice NW corner of ESU bldg. Side B:Gym telephone room.****Installed 2005****
Two 600pr 24awg copper teleco cable. Side A- 1200pr splice in manhole @ NW corner of ESU bldg. Side B- Galley 2700pr cabinet. *** INSTALLED 2005***
2700pr telecom cabinet feeds terminates two 600pr cables from 1200pr splice near NW corner of ESU bldg.***INSTALLED 2005*** Feeds Galley, clinic, MSST, North40 pedestal crushed conduit. not usable. 2005 -ITC Brashier
200pr copper 24awg from Galley Telecom cabinet to ISC BEQ equipment room. Feeds Clinic, Galley, BEQ OOD offices
200pr from Galley pedestal to North 40 pedestal. ***Installed 2005*** feeds floating Ahi pier, WPB bldg, ANT, MSST, Echo pier, ALL of North40 area
900pr telecom cabinet. 200pr feed terminates from Galley pedestal. this Pedestal feeds WPB pier, WPB bldg, AHI peir, Echo pier, the adjacent Sector Hono Trailer park, MSST 200pr feed from North40 pedestal to MSST pedestal.
Pier powermound feeds. 25pair each. ***Installed 2004***
25pair from 645 incoming demarc to Exchange demark in wherehouse.
100pr from MDF to supply. install date unknown
4pr outdoor cat5 from Club TR to security gate for phone extensions.
CATV feed to ESU 1st deck TR. also possible alt route for PBX/CGDN+ cabling. limited conduit space.
Model Space�