MOT003_RFP_Q&A_Matrix_3.pdf
PDF 98 KB Posted
- Solicitation number
- 70Z02318RMOT00300
About this file
MOT003 RFP Q&A Matrix 3
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFP 70Z02318RMOT00300
Questions and Answers
Ques.
Paragraph
Text Question Answer
60 Att 2, Sec 660- 1.4.14
660-1.4.14 [0001] Seats shall have a minimum forward knee clearance from the console of 18 inches in accordance with MIL-STD 1472 Section 5.10.3.4.4 Fig 64.
Can the USCG please explain how the Minimum Knee Clearance Dimension is to be measured in this application? The diagram referenced uses a writing surface shelf as the measuring point. A helm operator’s console does not have a similar writing surface shelf extending towards the operator. Using the waist of the operator, as a measuring point for this requirement drives the operator farther away from the console and conflicts with reachability requirements.
Because of the unique nature of marine helm consoles and [redacted] shock mitigating seating, and the lack of a comparable specification in MIL-STD-1472, we would like to request the USCG consider removal of 660-1.4.14. We believe that 660-1.4.13 (minimum thigh clearance) is sufficient to ensure the operator has clear leg space in front of and below the console.
Attachment 2, Section 660-1.4.13 and 660-1.1.14 have been deleted.
Attachment 2, Section 660-1.4.2, has been revised to clarifiy the knee, leg, and thigh clearances.
61 1449 Blk 8 We would like to pose the following question with regard to solicitation 70Z02318RMOT00300, USCG CB-L: "Offeror requests extension on solicitation response date."
No.
File details come from the government source that posted it.