Attachment 4 – Biometric Reader Verification Process
70Z02318RMMN00100
Verification Process. Proposed Reader must pass the following verification testing procedure for all Modes of Operation. Tests and expected results are as follows:
1. BADAUTH – Bad Authentication Certificate Test
2. CANCELED – Canceled Card List Test
3. EXPIRED – Expired Card Test
4. BADSIGN – Bad Signature Authority Test
5. UNTRUSTED – Untrusted Certificate Test
6. INSPECTOR – Full Validation Test (inspector’s Transportation Workers
Identification Credentials (TWIC)) Biometric match will be conducted with the inspector’s personal TWIC.
The reader shall yield the expected result outlined in the table, the tester/user must be able to confirm the results of the read transaction on the reader display and the reader shall properly operate in Modes 1 – 4. The following table breaks down each TWIC reader mode and expected result for each test.
Mode 1 Mode 2 Mode 3 Mode 4 Expected Result Expected Result Expected Result Expected Result
BADAUTH P F P F
CANCELED F F F F
EXPIRED F F F F
BADSIGN P F F F
UNTRUSTED F F F F
INSPECTOR P P P P
P = Passed, TWIC reader should indicate the test card is valid.
F = Failed, TWIC reader should indicate the test card is invalid and display failure reason.
TWIC readers designed to check all certificates on the TWIC regardless of the selected reader mode of operation shall identify the tested failure on the reader display.