7-CO24 Bid Set.pdf
PDF 7 MB Posted
- Attached to
- Ben Hawes Driving Range Bays
- Solicitation number
- 4484
- Issued by
- Daviess County, Kentucky
About this file
This is a bid set document for the City of Owensboro, Kentucky, related to the construction of a 5-bay driving range building at Ben Hawes Golf Course. The project requires a qualified contractor to provide all labor and materials for the construction. The bid set likely contains detailed specifications, drawings, and technical requirements necessary for contractors to prepare competitive proposals. Specific details regarding project timelines, response deadlines, site visit requirements, pre-bid meetings, and anticipated award dates should be contained within the bid documents. The contract term and any renewal options would be defined in the bidding instructions and contract language included in the complete bid package.
Pricing information, any set-asides for minority or women-owned businesses, funding sources, and budget allocations for the Ben Hawes Golf Course driving range project would be specified in the bid documents. Additional details regarding contractor qualifications, insurance requirements, performance bonds, and any other salient contracting conditions necessary for submission and award determination are contained within the complete bid set documentation.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project involves the construction of a new stand alone driving range building.
The building will be post frame construction with engineered wood trusses, and concrete foundations and slab. It will be an open air shelter with no walls, and will have electricity only.
Project Summary Scope of Work: Applicable Code
Building Code:
Plumbing Code:
Electrical Code:
Mechanical Code:
Energy Code:
Fire Code:
2018 Kentucky Building Code (2015 IBC) KY State Plumbing Law (815 KAR Chapter 20) 2023 National Electrical Code (NFPA 70) 2015 International Mechanical Code 2012 International Energy Conservation Code 2012 International Fire Code
Occupancy Classification: A-3 | Recreation (Golf Driving Range)
Construction Type:
Code Summary
VB (combustible, unprotected)
Building Elements - Fire Resistive Requirements:
Building elements, including structural frame, floors, and roof are permitted to be of combustible, unprotected, non-rated construction.
Exterior walls are not required to be of rated construction, being greater than 30 feet fire separation distance.
Incidental Use Separations: Incidental Use areas are not provided.
303.4
602.5 T601
T601
T602
T509
Number of Exits:
(Spaces)
Two (2) exist are required for any space having an occupancy load of 49 or more.
1006.2.1 T1006.2.1
Fire Alarm System: Manual fire alarm box is not required in Group A occupancies with occupant load in a 1 story building of less than 300.
907.2.1
Exercise Area: 50 gross
2,193sf / 50 = 44 occupants
T1004.1.2
Allowable Area for B Occupancy:
Allowable Height for B Occupancy:
1 stories and 40 feet 1 story and 13'-0" Actual
T504.3
Tabular Area: 6,000 sf
Total Actual Area: 2,193 sf
T506.2 506.3
T504.4
Occupancy Load:
Fire Suppression: Not Required. 903.2.1.3
1. Throughout the Drawings, where a single product is indicated, the named product establishes the salient features against which equivalent products from other manufacturers are to be evaluated.
2. Features include type, function, dimension, in-service performance, physical properties, appearance, warranty, and other characteristics.
3. Requests for substitutions will be evaluated if received no later than 7 days prior to date of bid opening.
Basis-of-Design Notes:
1.
2.
3.
4.
Color samples - metal roof & wall panels, post stain.
Truss shops.
Light fixtures & fans.
Unit Heater.
Submitals:
1.
2.
Provide Unit Price for one bay. Include all items including: wood framing, concrete slab, lighting, receptacles.
Provide Alternate Price for addition of 3 full bays.
Bidding Notes:
1 2 3 4 5 6 7 8
Pro Shop
Bathrooms
Electrical Room
Refer to Civil for site design scope.
S H E E T I N D E X
2625 Frederica Street, Owensboro Kentucky 42301
C I V I L
A R C H I T E C T U R A L
Drawings were created in, and are to be reproduced in color.
New Driving Range Building 400 Booth Field Road | Owensboro, Kentucky 42301
August 2026
Architect's Project # CO24
G000 Cover / Code Summary
C1.01 Site Plan / Public Facility Plan C2.01 Details
A101 Foundaiton Plan and Floor Plan A102 Ceiling Plan and Roof Plan A103 Building Elevations and Sections
E101 Electrical Plan
12" = 1'-0"
3D View
1" = 40'-0"1 Site Layout
ME409.08
ME404.36
TC406.75
TC407.56
GN404.35
GN404.35
GN404.35
GN404.35
3 40
B
EN
H A
W
ES
C O
U R
SE
D
R
IV
IN
G
R A
N G
E B
U
IL
D
IN
G B
O O
TH
F
IE
LD
R O
A D
O W
EN
SB
O R
O , K
Y
F R
ED
ER
IC
A
S
TR
EE
T
P.
O . B
O X
O
W
EN
SB
O
R O
, K
EN
TU
C
K Y
(2
) 6
-2
C iv il E ng in ee rin g La nd S ur ve yi ngW
E
SN
IN
C
EN
G
IN
EE
R
IN
G
B R Y A N T
Professional Engineer's Seal
O W
N
ER
D
EV
EL
O
PE
R
SHEET NO:
SH
EE
T
TI
TL
E:
PR
O
JE
C
T
TI
TL
E:
C
IT
Y O
F O
W
EN
SB
O
R O
PO
B
O X
O
W
EN
SB
O
R O
, K
EN
TU
C
K Y
-9
Signature
Date
PROJECT NO:
PERMITTING
DOCUMENTS
SCALE:
R
EV
IS
IO
N S:
N O
D
AT
E
D
ES
C R
IP
TI
O N
PL
AN
S
PR
EP
AR
ED
B
Y:
24-6997
PLAN DATE:
03-04-2025
SI
TE
P
LA
N
PU
B
LI
C F
A C
IL
IT
Y
PL
A N
C1.01
1" = 20'
GENERAL NOTES:
1. ALL PUBLIC IMPROVEMENTS MUST BE ACCORDING TO THE
OWENSBORO METROPOLITAN PUBLIC IMPROVEMENT
SPECIFICATIONS (THE PUBLIC IMPROVEMENT SPECIFICATIONS) PI
SPECS CAN BE FOUND AT www.iompc.org.
2. CONTRACTOR SHALL NOTIFY THE CITY ENGINEER'S OFFICE PRIOR
TO BEGINNING ANY CONSTRUCTION PHASES.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL
APPROPRIATE PERMITS FROM THE KENTUCKY DIVISION OF WATER
AND/OR ARMY CORPS OF ENGINEERS.
4. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL
APPROPRIATE PERMITS FROM ALL THE GOVERNING AGENCIES
THAT HAVE JURISDICTION OVER THE AREA WHERE THE WORK IS
PROPOSED TO BE DONE.
5. A CUT AND FILL PERMIT IS REQUIRED WHEN CUTTING OR FILLING IS
PROPOSED TO BE PERFORMED IN THE PROPOSED DEVELOPMENT.
6. A STREET CUT PERMIT IS REQUIRED FOR ALL WORK INSIDE THE
RIGHT-OF-WAY OF THE CITY OF OWENSBORO. CALL THE CITY
ENGINEERING OFFICE AT (270) 687-8641.
7. PRIOR TO MOBILIZATION, ALL SILT FENCE SHALL BE INSTALLED.
8. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR
REMOVING DIRT AND CONSTRUCTION DEBRIS CAUSED BY
CONSTRUCTION ACTIVITIES FROM THE CITY'S STREETS FOR THE
DURATION OF THE PROJECT.
9. ALL POTENTIAL EROSION SHALL BE CONTROLLED IN SUCH A
MANNER SO AS TO PREVENT ANY DISPLACEMENT OF SILT TO THE
ADJACENT PROPERTY OWNERS OR RIGHT-OF-WAY. THIS CONTROL
SHALL BE IMPLEMENTED THROUGH PROPER INSTALLATION OF SILT
FENCE DURING THE CONSTRUCTION DURATION AND MAINTAINED
UNTIL PROPER GROUND COVER HAS BEEN ESTABLISHED.
10. TOPSOIL STOCKPILES AND BORROW SITES SHALL BE
SURROUNDED BY SILT FENCES, RESEEDED, AND PLACED WHERE
SOIL EROSION WOULD NOT FLOW INTO WATERWAYS OR ADJACENT
PROPERTIES.
11. NO SOLIDS, INCLUDING BUILDING MATERIALS, SHALL BE ALLOWED
TO DISCHARGE INTO WATERS OF THE COMMONWEALTH.
12. THE EROSION CONTROL PLAN IS PREPARED AS A GUIDE FOR
INITIAL EROSION CONTROL MEASURES TO BE INSTALLED AT THE
JOB SITE. IF EROSION OCCURS IN OTHER SPECIFIC AREAS OF THE
PROPERTY DURING CONSTRUCTION, THE CONTRACTOR IS
RESPONSIBLE FOR INSTALLING SILT FENCE OR OTHER EROSION
CONTROL MEASURES AS NEEDED TO PREVENT EROSION AND/OR
CONTROL SEDIMENTATION.
13. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PROPER
INSTALLATION AND MAINTENANCE OF THE EROSION PREVENTION
AND SEDIMENTATION CONTROL. STRUCTURES, SILT FENCE, ETC.
SHALL BE INSPECTED REGULARLY AND SHALL BE REPAIRED,
CLEANED, AND/OR REINSTALLED AS NECESSARY TO MEET THE
INTENT OF THIS PLAN AND THE CITY OF OWENSBORO
REGULATIONS.
14. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE REMOVAL OF
EROSION PREVENTION AND SEDIMENTATION CONTROL
STRUCTURES AFTER CONSTRUCTION IS COMPLETE, BUT ONLY
AFTER PROPER GROUND COVER HAS BEEN ESTABLISHED.
15. THE GENERAL CONTRACTOR SHALL INSURE THAT ALL
SUBCONTRACTORS ARE FAMILIAR WITH THE EROSION CONTROL
MEASURES ON SITE AND THAT EACH SUBCONTRACTOR IS
RESPONSIBLE FOR ANY DAMAGE THEY CAUSE TO ANY EROSION
CONTROL STRUCTURE AND SHALL REPORT SAME TO THE GENERAL
CONTRACTOR IMMEDIATELY.
16. SILT FENCES TO BE CLEANED OUT WHEN THEY BECOME ONE
THIRD FULL. AFTER EVERY RAIN IN EXCESS OF ONE HALF INCH ALL
EROSION CONTROL MEASURES ARE TO BE INSPECTED AND
CLEANED OR REPAIRED AS NECESSARY.
17. ALL DISTURBED AREAS THAT REMAIN INACTIVE FOR MORE THAN 21
DAYS SHALL BE STABILIZED BY SEEDING, SODDING, MULCHING,
COVERING, OR BY OTHER EQUIVALENT EROSION CONTROL
MEASURES AS SOON AS PRACTICABLE, BUT IN NO CASE MORE
THAN 14 DAYS AFTER THE CONSTRUCTION ACTIVITY IN THAT
PORTION OF THE SITE HAS TEMPORARILY OR PERMANENTLY
CEASED.
18. ALL RAMPS, SIDEWALKS AND APRONS SHALL BE COMPLIANT WITH
THE MOST CURRENT DEPARTMENT OF JUSTICE ADA
REQUIREMENTS (ADA STANDARDS FOR ACCESSIBLE DESIGN, CODE
OF FEDERAL REGULATIONS, CURRENT EDITION).
19. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REPLACE
SIDEWALKS, CURBS, GUTTERS, AND/OR DRIVEWAY ENTRANCE
APRONS DAMAGED DURING CONSTRUCTION OF THEIR PROJECT.
20. EXISTING ROADWAYS DAMAGED DURING CONSTRUCTION SHALL BE
REPAIRED TO A CONDITION THAT IS EQUAL TO OR EXCEEDS
CURRENT CONDITIONS BY THE CONTRACTOR.
21. NO ENCROACHMENTS WILL BE ALLOWED UPON DEDICATED
EASEMENTS SHOWN ON PLAN SET.
22. EXISTING ROADWAY, PARKING LOT, DRIVING RANGE DAMAGED
DURING CONSTRUCTION SHALL BE REPAIRED TO A CONDITION
THAT IS EQUAL TO EXCEEDS CURRENT CONDITIONS BY THE
CONTRACTOR.
23. DISCHARGE FROM ALL SITE DOWNSPOUTS SHALL BE DIRECTED TO
STORM SEWERS, SWALES, AND/OR SHEET FLOW ROUTED TO THE
DETENTION BASIN.
24. THE PROPERTY OWNER IS RESPONSIBLE FOR SURFACE AND
SUB-SURFACE DRAINAGE RELATED TO HIS/HER LANDS, AND SHALL
PROVIDE FOR SUCH DRAINAGE IN A WAY AS TO PROPERLY
RELIEVE WATERS FROM THEIR LAND, WITHOUT OBSTRUCTING
EXISTING DRAINAGE PATTERNS OR INCREASING RUNOFF ONTO
ADJACENT PROPERTIES.
25. THE CONTRACTOR WILL MAINTAIN ON A ROUTINE BASIS ALL SILT
CHECKS AND EROSION CONTROL ITEMS UNTIL PERMANENT
GROUND COVER IS ESTABLISHED AT SITE, OR THE DEVELOPMENT
IS 75% COMPLETE, WHICHEVER COMES LATER.
26. THE SUBJECT PROPERTY IS NOT LOCATED IN A SPECIAL FLOOD
HAZARD AREA OR FLOODWAY PER F.I.R.M. NO. 21059C0116E,
EFFECTIVE JULY 31, 2024.
VICINITY MAP
SITE
ENGINEERING DEPT
APPROVED BY
Date:
Signature:
MATCH EXISTING ELEV.
REGRADE CONTOUR
SHEET FLOW DIRECTION
ME452.06
FINISH FLOOR ELEV.
TOP OF CONCRETE ELEV.TC445.00
GROUND ELEV.GN450.50
FFE
�+0�(''6��
)4#2*+%�5%#.'
��KPEJ������HGGV
LEGEND
EX. SEWER MANHOLE
EX. LIGHT POLE
EX. WATER METER
EXISTING CONCRETE
EX. CONTOUR
PROJECT CONTROL POINT
EX. SANITARY SEWER
EX. ELECTRIC METER
PROJECT CONTROL POINTS:
DESCRIPTION
ALL PROJECT CONTROL POINTS ARE NAD 83 (2011), KY SOUTH, GEOID ~ 12b
1 1/2" REBAR, 18" IN LENGTH, SET W/ CAP, BEI CONTROL PT
2,175,965.39
NORTHING EASTING ELEV.
1,226,454.43 408.82
2,175,977.88 1,226,477.42 408.87MAG NAIL SET IN ASPHALT
EX. GAS LINE
EX. UTILITY POLE
EX. GUY-WIRE
EX. TREE / LANDSCAPING
EX. GAS METER
EX. SEWER CLEANOUT
EX. TELEPHONE PEDESTAL
SILT FENCE
THE PROPOSED BUILDING SHIFTED TO THE NORTH BY 6-FT.
08/21/2025 AMENDED PUBLIC FACILITY PLAN NOTE:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
D
ET
A
IL
S
C2.01
NOT TO SCALE
B
EN
H A
W
ES
C O
U R
SE
D
R
IV
IN
G
R A
N G
E B
U
IL
D
IN
G B
O O
TH
F
IE
LD
R O
A D
O W
EN
SB
O R
O , K
Y
F R
ED
ER
IC
A
S
TR
EE
T
P.
O . B
O X
O
W
EN
SB
O
R O
, K
EN
TU
C
K Y
(2
) 6
-2
C iv il E ng in ee rin g La nd S ur ve yi ngW
E
SN
IN
C
EN
G
IN
EE
R
IN
G
B R Y A N T
Professional Engineer's Seal
O W
N
ER
D
EV
EL
O
PE
R
SHEET NO:
SH
EE
T
TI
TL
E:
PR
O
JE
C
T
TI
TL
E:
C
IT
Y O
F O
W
EN
SB
O
R O
PO
B
O X
O
W
EN
SB
O
R O
, K
EN
TU
C
K Y
-9
Signature
Date
PROJECT NO:
PERMITTING
DOCUMENTS
SCALE:
R
EV
IS
IO
N S:
N O
D
AT
E
D
ES
C R
IP
TI
O N
PL
AN
S
PR
EP
AR
ED
B
Y:
24-6997
PLAN DATE:
03-04-2025
&21&5(7(�6,'(:$/.�'(7$,/
*NOTE:
THICKNESS 4" TYP.
(SEE PLAN FOR OTHER
REQUIREMENTS)
4" COMPACTED DGA
WWF 6x6 W1.4xW1.4 1/2"
4" *
EXPANSION JOINT FILLER
5'
(TYP.)
20'-0"
MARK W/ SCORING
TOOL 3/4" DEEP
(TYP.)JOINT SEALER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
A103 4
A103
A103
A103
A103
B 1'
/4
8'
/4
987654321
82' - 6"
10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"
A
GFIGFIGFIGFIGFIGFIGFI
Alternate 30' - 0"50' - 0" Base Bid
7777777
6666666
4 4 4Atl. Atl.
Atl. Atl.
Atl.
Atl.
G
FI
3 3Atl. Atl.
Atl.
Atl.
Atl.
#Floor Plan Key Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Fire extinguisher mounted on post.
4" 4,000 P.S.I. concrete (smooth finish) with 6x6-W1.4xW1.4 welded wire fabric, over 6" compacted DGA, over clean, dry compacted subbase at 95% proctor. Provide control joints at 10'-0" O.C. maximum. Contractor to seal concrete.
Full motion tv wall mount bracket w/ articulating arm for ball tracking system @ 8' - 0" a.f.f. to center. Provide and install by GC.
Power/Data junction box (weatherproof) by GC for TopTracer monitor. See Toptracer specifications.
Toptracer climate-controlled server rack, by Owner vendor. GC to coordinate requirements with Vendor.
Tee Divider, by Owner.
5' x 8' Turf Pad and Tee, by Owner.
See Civil for sidewalk connection to existing Pro Shop.
Coordinate with Owner security for camera location and requirements. Provide blocking as necessary.
General Floor Plan Notes:
1.
2.
All dimensions on floor plans are from face of finish gypsum board, face of masonry, face of concrete or centerline of columns unless noted otherwise.
Provide 6x6 treated posts. Stain color selected by Owner. Minimum 4'-0" embed into ground with concrete casing. Connect with Simpson StrongTie CC Column Cap.
B
987654321
A
10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"10' - 0"
2' - 0" ⌀ x 3' - 0" deep on 10" deep concrete pad.
50' - 0" (Base Bid) 30' - 0" Alternate
4" Reinforced concrete slab (wwf 6x6 w1.4xw1.4 in center of slab) over 6-mil polyethylene vapor barrier, over compacted DGA, over undistributed soil with EPA approved soil insect treatment.
Provide turn-down at slab edge at perimeter, unless noted otherwise.
Sawn control joint, typical
1'
/4
8'
8'
8'
/4
Roof Loads:
Dead Load = 15 psf Live Load = 20 psf
Floor Loads:
Slabs = 125 psf
Seismic:
Resisting Frame System = Timber Frame Seismic Design Category = E Response Modification Factor (R) = 1.5 Seismic Response Coefficient (Cs) = 0.38 Base Shear = 35.7k Design Procedure = Equal Lateral Force Risk Category: I
Wind:
Design Wind Speed = 115 mph Importance Factor = 1.0 Wind Exposure = C Internal Pressure Coefficient = 0.18
Snow:
Ground Snow Load = 15 psf Snow Exposure (Ce) = 1.0 Snow Importance (Is) = 1.0 Thermal Factor (Ct) = 1.0 Sloped Roof Snow Load = 11 psf Rain on Surcharge = 5 psf
Structure Load Notes:
C I V I L
2625 Frederica Street, Suite 2B | Owensboro, KY 42301 Office | 270-663-1256
Drawings were created in, and are to be reproduced in color.
Ben Hawes Golf Course New Driving Range Building
400 Booth Field Road | Owensboro, Kentucky 42301
August 2026
Foundaiton Plan and Floor Plan
A101
Architect's Project # CO24
3/16" = 1'-0"1 First Floor Plan
3/16" = 1'-0"2 Foundation Plan
No. Description Date
A103
B
987654321
A
2"
2"
108' - 0"
112' - 0 7/8"
3 3 3 3 3 3 3 3
Camera 1 Camera 2 if alternate accepted
Camera 2
Alt.
Alt.
Alt.Alt.
Alt.
Alt.
4 4 4 4 4 4
5 5 5 5 5 5 5 5
5 5 5 5 5 5 5 5
5 5 5 5 5 5 5 5
Alt. Alt.
Alt.Alt.
Alt. Alt.
Alt.
Alt.
Alt.
Alt.
Alt.
A103
DSDS
B
987654321
A
2"
82' - 0"
/2
DS
10' Snow guard. GC verify sidewalk position before installation. Center snow guard on sidewalk.
Add Alternate 30' - 0"
Reflected Ceiling Plan Key Notes:
1.
2.
3.
4.
5.
Prefinished metal panel ceiling.
Ceiling fan. (Basis of Design: Hunter | Cassius Outdoor 52" | White) Electric radiant heater. (Basis of Design: Infratech | All Weather C-Series C-3024 SS) Flat screen TV, by Owner.
1x4 LED light. (Basis of Design: Lithonia | FEM LED DC2DC, 4,000 LM, 4K)
Roof System:
1. Prefinished standing-seam metal panel (minimum 26 gauge) (full length panels) over roofing underlayment and 5/8" sheathing and engineered wood trusses.
2. Minimum Gutter Size: 5" x 5"
3. Minimum DS Size: 3" x 4"
C I V I L
2625 Frederica Street, Suite 2B | Owensboro, KY 42301 Office | 270-663-1256
Drawings were created in, and are to be reproduced in color.
Ben Hawes Golf Course New Driving Range Building
400 Booth Field Road | Owensboro, Kentucky 42301
August 2026
Ceiling Plan and Roof Plan
A102
Architect's Project # CO24
3/16" = 1'-0"1 Ceiling / Lighting Plan
3/16" = 1'-0"2 Roof Plan
Level 1 100' - 0"
Truss Brg 1 108' - 0"
B A
Truss Brg 2 110' - 8"
Level 1 100' - 0"
Truss Brg 1 108' - 0"
A103
987654321
Truss Brg 2 110' - 8"
Level 1 100' - 0"
Truss Brg 1 108' - 0"
A103
9 8 7 6 5 4 3 2 1
Truss Brg 2 110' - 8"
Level 1 100' - 0"
Truss Brg 1 108' - 0"
BA
Truss Brg 2 110' - 8"
Level 1 100' - 0"
Truss Brg 1 108' - 0"
A103
BA
8' - 0" 16' - 6"
2" / 12"
Truss Brg 2 110' - 8"
112' - 0 7/8"
Level 1 100' - 0"
Truss Brg 1 108' - 0"
B
Reinforced concrete slab, refer to floor plan.
3'
2' - 0"
Concrete pad
(2) #4 bars 1'-6" long through bottom of post
Turn down slab edge
Downspout in 6" PVC hub.
Prefinished metal gutter and downspout.
Prefinished standing seam metal roof over roofing underlayment and 5/8" sheathing and engineered wood trusses @ 24" o.c.
Attach sheathing with 8d common nails at 6" on center at edges and intermediate supports.
Prefinished metal soffit
1x8 wrapped w/ prefinished metal
Prefinished metal wall panels over air/water barrier and 7/16" OSB (provide drip edge)
Switch box, beyond
All weather infrared radiant heater
Metal panel ceiling
6" corrugated pipe to daylight. Provide a minimum of 1'-6" cover.
1.
2.
3.
4.
5.
6.
7.
8.
Prefinished metal wall panels. Color TBD.
Prefinished standing seam metal roof. Color TBD.
Prefinished metal trim. Color to match roof.
Prefinished metal panel ceiling. Color TBD.
Prefinished metal gutter and downspouts. Color TBD.
Wood columns and beam. Stain.
Tee divider, by Owner.
Weatherproof power/junction box, per TopTracer specifications.
#Elevation Key Notes:
C I V I L
2625 Frederica Street, Suite 2B | Owensboro, KY 42301 Office | 270-663-1256
Drawings were created in, and are to be reproduced in color.
Ben Hawes Golf Course New Driving Range Building
400 Booth Field Road | Owensboro, Kentucky 42301
August 2026
Building Elevations and Sections
A103
Architect's Project # CO24
3/16" = 1'-0"4 Building Elevation - West
3/16" = 1'-0"1 Building Elevation - South
3/16" = 1'-0"3 Building Elevation - North
3/16" = 1'-0"2 Building Elevation - East
3/16" = 1'-0"5 Section 1 3/4" = 1'-0"6 Section Detail
GFCI GFCI GFCI GFCI GFCI GFCI GFCI
G
FC
I
B
987654321
A
GFI, below server box
4 4 4 4 4 4 4 4
Add Alternate 30' - 0"
5 6 1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
All work shall be installed per NFPA 70: National Electrical Code.
Furnish and install all hangers and support steel fabrications required for the proper support and seismic bracing of all light fixtures, conduits, equipment, etc.
All work shall be performed in a neat and workmanlike manor and according to good practice.
Contractor responsible for all permits, certificates, and licenses required for the work.
All receptacle outlets shall be mounted at 1'-6" above floor, unless noted otherwise. Provide 20amp 125vac, specification grade. Maximum of (4) receptacles on one 20 amp circuit.
Provide GFCI receptacles as required by code; minimum within 4'-0" of water source.
All light switches shall be mounted with center at 4'-0" above floor. Provide 20amp 125vac, specification grade.
Provide all materials required to properly power all devices and equipment installed. Refer to manufacturer's instructions for devices. All materials used shall be approved by Underwriter's Laboratories.
No exposed wire runs.
Concealed wire runs shall be EMT or MC cable.
Liquid tight flexible metal conduit shall be used for all mechanical equipment connections.
Crimp tight connections shall not be allowed.
Disconnect switches shall be 'Heavy Duty' rated, NEMA 1 or 3R, as required.
Provide all junction boxes as required.
Contractor shall visit the site and be responsible for exact circuit lengths and installation requirements.
Coordinate with other trades to avoid conflict. No claim for costs will be allowed for relocating equipment that interferes with other trades work.
Drawings are diagrammatic and indicate the general arrangement of electrical installation. The exact location and routing of conduit, receptacles, etc., shall be determined in the field.
All penetrations through walls, floors, or roofs, shall be provided with properly sized sleeve and sealed.
Contractor shall size wiring to minimize voltage drop based upon in field routing. Voltage drop shall not exceed 3%.
Provide a 1/2" conduit with pull wire for all data outlets routed above ceiling and capped unless otherwise noted.
Contractor shall provide laminated identification tags for panels and disconnect switches.
Panel board directories shall be typed.
All data wire to be furnished and installed by Owner's low voltage contractor.
Coordinate the location of the mechanical equipment and verify that the branch circuit protection, and wire data is compatible with equipment needs prior to rough-in. Notify the owners representative of any discrepancies prior to rough-in.
Refer to Top Tracer Design Pack.
General Electrical Plan Notes:
1.
2.
3.
4.
5.
6.
Building is to be powered from existing panels in Par 3 building.
Post-mounted climate-controlled server rack provided by TopTracer, and will not be provided by the General Contractor. General contractor is responsible for dedicated duplex power outlet at location.
(1) 1" conduit with pull string and (2) 2" conduit with pull string to above ceiling.
Weatherproof power / data junction box for TopTracer Monitor. See TopTracer specifications. GC to provide 1" conduit with pull string.
GC responsible for conduit pathway from new building to existing electrical panels. GC shall repair and replace all grade and sidewalks removed to match existing.
GC responsible for trench and infill for Owner provided and Owner installed data cable and conduit. Verify path with Owner. GC shall provide conduit in the building footprint.
Electrical Plan Key Notes: #
B
987654321
A
A A A A A A A A
AAAAAAAA
A A A A A A A A
333333 3
B B
5 5 5 5
6666666
B
4 Alternate
Add Alternate 30' - 0"
9 9 9Alternate
Electrical Ceiling Plan Key Notes:
1.
2.
3.
4.
5.
6.
7.
8.
9.
The lights shall be controlled at the breaker in the panels at the Par 3 building. All lights shall be grouped into as few breakers as possible.
The fans shall be controlled at the breaker in the panels at the Par 3 building. All fans shall be grouped into as few breakers as possible.
The heaters shall be controlled at the breaker in the panels at the Par 3 building. All heaters shall be grouped into as few breakers as possible.
Coordinate with TopTracer for exact light location. Light shall be controlled in the same manner as the ceiling lights. Provide all mounting accessories.
Ceiling fan. (Basis of Design: Hunter | Cassius Outdoor 52" | White) Electric radiant heater. (Basis of Design: Infratech | All Weather C-Series
C-3024 SS).
Install mounting box and blocking for security camera. Coordinate with Owner on location. Camera and wire by Owner.
Junction box for Top Tracer A.P. GC to provide box.
Install mounting box for Top Tracer camera. GC to provide box.
New Construction
Rough in for future installation
Duplex Receptacle
Duplex Receptacle -
GFCI
Data Receptacle
Electrical Legend:
Existing Panel "A"
Existing Panel "B"
Existing Panel "C"
Existing Disconnect
400 A 240v
200 A 240v
100 A 240v
100 A 240v
Par 3 Lights 50
Driving Range Lights
Receptacle
Par 3 Lights 50
50 Par 3 Lights
60 Electric Heaters
60Electric Heaters
20Ceiling Fans
20 Receptacle 20Receptacle
20 Receptacle 20Receptacle
20 20Televisions
20 Lights 20Lights
Top Tracer
Par 3 Lights 50
Fountain
Water Heater
Par 3 Lights 50
20Pro Irrigation
20 Hand Dryer 20Hand Dryer
20Water Heater
Not Labeled 20
Not Labeled
Bathroom Heater
Par 3 Lights 30
20Not Labeled
20 Not Labeled 20Bathroom Heater
20Washer
20 Not Labeled
C I V I L
2625 Frederica Street, Suite 2B | Owensboro, KY 42301 Office | 270-663-1256
Drawings were created in, and are to be reproduced in color.
Ben Hawes Golf Course New Driving Range Building
400 Booth Field Road | Owensboro, Kentucky 42301
August 2026
Electrical Plan
E101
Architect's Project # CO24
3/16" = 1'-0"1 Electrical Plan
3/16" = 1'-0"2 Electrical Ceiling Plan
Lighting Fixture Schedule Tag Count Description Series Manufacturer Model Comments
A 24 LED Panel 1'-0" x 4'-0" Lithonia FEM LED DC2DC, 4,000 LM, 4K Contractor Select
B 3 Flood Light Surface Mounted Lithonia ESXF5 ALO SWW2 XVOLT YS DDB Contractor Select
No. Description Date
12" = 1'-0"
Electrical Panel Diagram
Electrical Panel A
Electrical Panel B
Electrical Panel C
Electrical Light Pole Base
| Sheets: A101 - Foundaiton Plan and Floor Plan |
| Sheets: A102 - Ceiling Plan and Roof Plan |
| Sheets: A103 - Building Elevations and Sections |
| Sheets: G000 - Cover / Code Summary |
File details come from the government source that posted it. Updated .