This document includes a presentation and solicitation for a roofing project at the Bangor, Maine Federal Aviation Administration facility. The presentation reviews the scope of work, which involves preparing and installing new 60 mil PVC roofing systems on the base building and link, tower cab, E/G building, and work shop totaling approximately 8,000 square feet. Additional work includes repairing and replacing existing roofing, removing and replacing copings, downspouts, and other roof elements. Contractors are invited to submit questions by January 14th. The solicitation is available on a full and open basis under NAICS code 238160 with a size standard of $16.5 million. The estimated price range for the roofing project is $100,000 to $300,000. The performance period is 84 calendar days from notice to proceed.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/5/2022
RFO – BGR ROOF REHAB PROJECT
NOTICE ID: 697DCK-22-R-00055
JANUARY 5, 2022, 0900 TO 1100
BANGOR, ME
AGENDA:
1. ATTENDANCE
2. PURPOSE: REVIEW FACILITY LAYOUT &
SCOPE OF WORK
3. REVIEW SCOPE OF WORK
• BASE BUILDING & LINK
• EXTERIOR & INTERIOR WORK
• TOWER CAB
• EXTERIOR & INTERIOR WORK
• E/G BUILDING
• WORK SHOP
4. SUBMITTING QUESTIONS & CLARIFICATIONS
617 GRIFFIN RD,
BANGOR, ME
• For Questions/Clarifications:
• Submit/follow-up in writing to:
• Robert.Higgins@faa.gov & Geovanni.Santos@faa.gov
• Q&As will be consolidated in the Solicitations Requirements.
BASE BUILDING & LINK
1. Base Building & Link:
a. Prepare, clean, and install approximately 6600 SF of 60 mil PVC roofing system over existing roof. PVC system shall be composed of rigid insulation, cover board, and PVC membrane.
b. Repair/Replace approximately 300 SF of existing roofing. New installation shall match existing roofing system profile. New installation shall be fully adhered PVC, over rigid board, insulation, vapor barrier, and 5/8" gypsum board. Roof edging shall be PVC clad metal, fastened to vertical sub-girts.
c. Remove (3) roof structures (Chimney Cap, Boiler Opening, Roof Hatch). Restore roofing system and metal decking to match existing.
d. Provide bracing support to existing boiler breach
e. Remove and replace approximately 320 LF of copping assembly.
f. Remove and replace (10) downspout assemblies
g. Install new walkway pads
h. Install fall protection device
i. Install new railing for access ladder
j. Repair link interior wall. Paint to match.
k. Replace link ceiling tiles and insulation as shown on plans.
60 mil PVC membrane
Note: Contractor to provide tapering plan
TOWER CAB
2. Tower:
a. Prep, clean, and install approximately 617 SF of 60 mil
PVC roofing system.
b. Installation to include, at a minimum, mechanically fastened insulation and protective board over existing roofing. PVC membrane fully adhered.
c. Remove and replace existing copping system with similar.
d. The parapet wall and curb flashing detail membrane shall be removed to the substrate.
e. Install new walkway pads, match existing
f. Re-attached interior cab roof insulation board.
g. Remove and replace mechanical storm louver found in tower junction level.
E/G BUILDING
3. E/G building
a. Prepare, clean, and install approximately 422 SF of new
60 mill PVC roofing system.
b. Remove and replace copping system
c. Restored existing lighting system for E/G building
WORK SHOP
1. Work Shop
a. Demolished existing roof to substrate.
b. Prepare, clean, and install approximately 1700 SF of new
60 mill PVC roofing system.
c. Install new fascia system
(EXISTING ROOF HAS A CONCRETE DECKING,
APPEARS TO HAVE FULLY ADHERED EDPM SYSTEM).
THE END