This document provides details for Addendum No. 001 to the construction contract for the MSTB Facility project. The addendum responds to bidder questions and revises the construction documents. Drawing revisions include noting the PEMB roof insulation system, deleting an allowance specification, and adding signage information. Deleted is Section 01 14 00 (Allowances) as the FAA will directly contract testing. Added is Section 10 14 00 (Signage) providing requirements for room, door and other signs. Replaced drawings include revisions to wall sections, building sections, plans and details to call out items like insulation and signage locations. Specification section 10 14 00 includes sign type, material, mounting and accessibility requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 15. 20-042069 MSTB Geotech.pdf | ||
| 6973GH-24-R-00011-0002.pdf | ||
| 13. 6973GH-24-R-00011;Questions and Answers.pdf | ||
| 6973GH-24-R-00011-0001.pdf | ||
| 2. SOW 20-042069 Mobile Systems Test Bed.pdf | ||
| 12. Contractor Release.pdf | ||
| 8. Past Performance Survey.docx | DOCX document | |
| 11. SF 25A Payment Bond.pdf | ||
| 9. Wage Rate Decision No_OK 20230049.pdf | ||
| 10. SF 25 Performance Bond.pdf | ||
| 6973GH-24-R-00011.pdf | ||
| 3. 20-042069 MSTB REBID SPECIFICATIONS.pdf | ||
| 5. AMP400 OC Construction contractors combined.pdf | ||
| 6. Attachment F-4 - 20-042069 Mobile Systems Test Bed.pdf | ||
| 7. Past Performance Experience Information Form.docx | DOCX document | |
| 1. Section B - Supplies or Services-Prices.xlsx | XLSX spreadsheet | |
| 4. 20-042069 MSTB REBID DRAWINGS.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM NO. 001
Date of Issue: November 16, 2023
CONTRACT NO. 6973GH-21-D-000044
WORK ORDER 6973GH-22-F-00856
MSTB FACILITY
US DEPT. OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
Prepared by:
108 South Broadway
Edmond, Oklahoma 73034
405.840.1111 (v) 405.840.1191 (f)
Architect
Thomas Small, AIA
11/16/2023
Addendum No. 001 MSTB, FAA-OKC Work Order 6973GH-22-F-00856 Issued: November 15, 2023
Addendum No. 001 forms a part of the Contract Documents and modifies the original bid documents. Items in this Addendum take precedence over the original documents. Addendum No. 001 consists of the following:
General Information:
The purpose of the Addendum is to respond to Bidders questions and revise the construction documents in response.
Revisions are as follows:
1) Drawing revisions to indicate PEMB Batt roof insulation system noted in Specification
Section 07.21.16.
2) Deletion of Allowance specification Section 01 14 00.
3) Addition of Signage information on Sheet A.201 and revised specification section 10
14 00-Signage.
Drawings:
1) Refer to attached Sheet A.201. Signage information has been added to this sheet.
This is a new sheet that replaces, in its entirety, the original A.201 sheet in the Construction Documents.
2) Refer to attached Sheet A.501. Revisions to this sheet are the wall hatch designating the foam insulation. This is a new sheet that replaces, in its entirety, the original A.501 sheet in the Construction Documents.
3) Refer to attached Sheet A.502. Revisions to this sheet include noting the PEMB roof insulation per spec section 07.21.16. This is a new sheet that replaces, in its entirety, the original A.502 sheet in the Construction Documents.
4) Refer to attached Sheet E.801, Revisions to this sheet include noting CBP wireless access points adjacent to FAA wireless access points, conduit size increase to 2” conduit, and additional conduit and junction boxes between IDF Room 106 and FAA Telecom 107. This is a new sheet that replaces, in its entirety, the original E.801sheet in the Construction Documents.
5) Refer to attached Sheet A.702, Revisions to this sheet include noting the PEMB roof insulation per spec section 07.21.16 and revising the details to not show foam insulation on the roof deck. This is a new sheet that replaces, in its entirety, the original sheet A.702 in the Construction Documents.
Specifications:
1) Delete Section 01 14 00-Allowances. The FAA will contract directly with a testing agency to perform the special inspections and test. Therefore, specification section 01 21 00-Allowances shall be deleted from the Construction Documents. Note that normal testing and inspections on this project are the responsibility of the Contractor and are to be included in the contract amount.
Addendum No. 001 MSTB, FAA-OKC Work Order 6973GH-22-F-00856 Issued: November 15, 2023
2) Refer to attached Section 10 14 00-Signage. This section provides additional information on required signage for the Building.
Bid Documents:
None.
Attachments:
1. A.201 Floor Plan
2. A.501 Building Sections
3. A.502 Wall Sections
4. A.702 Wall Section Details
5. A.801 Telecom Plan and Details
6. Specification Section 10 14 00-Signage
- End of Addendum No. 001 -
A.301
A.301
A.301
A.301
AA
BB
CC
30' - 0"20' - 0"5' - 0"20' - 0"20' - 0"
95' - 0"
BAY 2
BAY 3
BAY 4
BAY 1
GEN.
MAINT/STRG.
SYSTEMS
UNI-TLT.
J.C.
STRG.
IDF RM. -
CBP
FAA
TELECOM
ELECT.
RISER
102A103A104A 101A
101B
104B
106A 112A
113A
109A108A107A
102C
A.501
A.501
A.501
102B
A.501
105A
110A 111A 109B
A.401
G
H
A
D
D
DB
A
A
B C
C
B D
RTU-1,
RE:
MECH
GUH-2, RE: MECH GUH-1, RE: MECH
CU-1, RE:
MECH
DCU-1 AND DCU-2,
RE: MECH
CU-1, RE:
MECH
FF-2 ABOVE
DOOR, RE:
MECH
VF-1, RE:
MECH
LV-1, RE:
MECH
LV-3, RE:
MECH
LV-2, RE:
MECH
3' - 0" 14' - 0" 3' - 0"3' - 0" 14' - 0" 3' - 0"3' - 0" 2' - 0"
12' - 0" 4' - 1"
3' - 0"
11" 2' - 6"
4' - 0"
2' - 6" 14' - 0" 7' - 0"
A.701
A.701
A.701
3 A.701
4' - 9"
E01
E02 E05
E05
E05
E04
E03
E05
CONCRETE PAD.
RE:4/M-301
CONC.PAD.
RE:4/M-301
B
B
A
F F F
CONCRETE PAD.
RE:4/M-301
1'
3.2
3.2
20' - 0" 1' - 1"
3' - 4" 6' - 11" 3' - 4" 5' - 4" 3' - 4" 1' - 8"
20' - 0" 9' - 0" 14' - 0" 7' - 0"
95' - 0"
10' - 10" 13' - 11 1/2" 20' - 2 1/2"
4' - 5 1/8"
1"
65' - 0" 30' - 0"
METAL BUILDING COLUMN,
PAINT TO MATCH WALL
PANELS
20' - 0" 25' - 0"
45' - 0" 30' - 0"
CLR.
1' - 10"2' - 6"2' - 6"
DESIGNED
WORK ORDER NO.
DRAWN
OFFICE OF
ISSUED BY DATE:
PREPARED BY
REV DATE
APPROVED BY
DESCRIPTION APP'DCHECK
OF
ADD
DAP
2020-042069
REVIEWED BY
DRAWING NO.
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FACILITY MANAGEMENT
AMP-400
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
MSTB FACILITY
SMALL ARCHITECTS HAROLD STONG
100% FOR CONSTRUCTION SUBMISSION
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a
"need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
CONTRACT No. 6973GH-21-D-000044
FLOOR PLAN
A.201
October 17, 2023
26 75
1/8" = 1'-0"A.201
FLOOR PLAN & EQUIPMENT
SCHEDULE
EQUIPMENT SCHEDULE
MARK ACCESSORY QUANTITY INSTALLATION
MANUFACTURER (OR
EQUAL) MODEL NUMBER
E01 AIR COMPRESSOR 1 C.F/C.I QUINCY QGS-10 17
E02
EMERGENCY EYE WASH
W/SHOWER 2 C.F./C.I BRADLEY S19314SPR
E03
TWO TON, 1 BAY
BRIDGE CRANE.
208-VOLT, 3-PHASE
1 C.F/C.I
SPANCO /
HARRINGTON NER 02 0L
E04
2 PERSON FALL
ARREST SYSTEM 1 C.F/C.I RIGID LIFELINES PT 500
E05 AIR HOSE REEL 4 C.F/C.I GLOBAL
3/8" x 50' HOSE REEL W/50'
HOSE,300 PSL
GENERAL NOTES:
1. REFER TO SHEET M-201 FOR DUCTWORK
LAYOUT.
2. REFER TO SHEET P-201 FOR ROUTING OF
COMPRESSED AIR LINES.
3. REFER TO SHEET E-901 FOR WAP LOCATIONS.
COORDINATE FINAL LOCATIONS WITH USER.
4. CONTRACTOR SHALL PROVIDE AND INSTALL
IGNITION BARRIER ON ALL EXPOSED SPRAY
FOAM INSULATION IN THE BUILDING.
5. ALL EXTERIOR DIMENSIONS TAKEN FROM PEMB
GRIDLINES AND FACE OF OPENINGS.
6. ALL INTERIOR DIMENSIONS TAKEN FROM PEMB
GRID LINES AND CENTERLINE OF METAL STUD
PARTITIONS.
7. AT DOWNSPOUTS LOCATIONS DISCHARGING
ONTO LAWN AREAS, PROVIDE AND INSTALL
SPLASHBLOCKS.
SIGNAGE SCHEDULE
MARK
SIGN TYPE
PER
SECTION
10 14 00 SIGN TEXT
1 TYPE 1B GEN. MAINTENANCE 109
2 TYPE 1B JANITOR 111
3 TYPE 2R RESTROOM (SIGN 1) 110 (SIGN 2)
4 TYPE 1B STORAGE 105
5 TYPE 1A 106
6 TYPE 1A 112
7 TYPE 1B ELECTRICAL 113
8 TYPE 1B FIRE RISER ROOM - SEE NOTE #1
9 TYPE 1A 107 - SEE NOTE #1
SIGNAGE NOTE:
1. PROVIDE SIGNAGE PER SPECIFICATION SECTION 14 10 00-SIGNAGE ON ALUMINUM IN LIEU
OF PLASTIC MATERIAL.
1 11/16/23 ADDENDUM #1
ADD 1
FINISH FLOOR
100' - 0"
RIDGE
136' - 9"
A.501
A.501
A.501
PRE-FINISHED METAL
ROOF PANELS BY PEMB
MANUFACTURER, TYP.
PRE-FINISHED METAL
WALL PANEL
BY PEMB
MANUFACTURER, TYP.
RIGID FRAME BY
PEMB MANUFACTURER
PRE-FINISHED METAL WALL
PANEL BY PEMB
MANUFACTURER, TYP.
PRE-FINISHED OVERHEAD
COILING DOOR, TYP.
PRE-FINISHED METAL WALL
PANEL TO 8'-0" A.F.F.
SPRAY FOAM INSULATION WITH
THERMAL BARRIER
PRE-FINISHED METAL WALL
PANEL TO 8'-0" A.F.F.
A.502
A.502
Sim
O.H.
B.O. HIGH WINDOW
126' - 0"
110 109 108 107
105A110A111A109B
101B
BAY 4
BAY 3
BAY 2
BAY 1
101 105112
5" CONC. SLAB ON
VAPOR BARRIER ON
4" GRAVEL BASE ON
SUB BASE. RE: S.200
SELF SUPPORTING, ONE TON,
SINGLE BAY, OVERHEAD
BRIDGE CRANE
2-PERSON, SUSPENDED
FALLARREST MONORAIL
SYSTEM, BRACE RAIL TO
STRUCTURE ABOVE 8'-0" O.C
PEMB ROOF
INSULATION W/ LINER
FINISH FLOOR
100' - 0"
EAVE
130' - 0"
RIDGE
136' - 9"
A.501
PRE-FINISHED METAL WALL PANEL
BY PEMB MANUFACTURER, TYP.
PRE-FINISHED METAL
ROOF PANELS BY PEMB
MANUFACTURER, TYP.
PRE-FINISHED METAL
GUTTER & DOWNSPOUTS, TYP.
PRE-FINISHED METAL WALL PANEL
BY PEMB MANUFACTURER, TYP.
PRE-FINISHED OVERHEAD
COILING DOOR, TYP.
SPRAY FOAM INSULATION WITH
THERMAL BARRIER
PRE-FINISHED METAL WALL
PANEL TO 8'-0" A.F.F.
RIGID FRAME BY PEMB MANUFACTURER.
A.502
A.502
Sim
PRE-FINISHED OVERHEAD
COILING DOOR, TYP.
PRE-FINISHED METAL ROOF PANELS
BY PEMB MANUFACTURER, TYP.
B.O. WINDOW
120' - 0"
B.O. HIGH WINDOW
126' - 0"
101B101A
112 111BAY 1
5" CONC. SLAB ON
VAPOR BARRIER ON
4" GRAVEL BASE ON
SUB BASE. RE: S.200
PAVING. RE: CIVIL
SELF SUPPORTING, ONE TON,
SINGLE BAY, OVERHEAD
BRIDGE CRANE.
2-PERSON, SUSPENDED FALLARREST
MONORAIL SYSTEM, BRACE RAIL TO
STRUCTURE ABOVE 8'-0" O.C
< 8' MAX CENTERS
7' - 10 1/2"
PEMB ROOF
INSULATION W/ LINER 2
FINISH FLOOR
100' - 0"
EAVE
130' - 0"
RIDGE
136' - 9"
LOW EAVE
118' - 4"
A.501
PRE-FINISHED METAL ROOF PANELS
BY PEMB MANUFACTURER, TYP.
PRE-FINISHED METAL
GUTTER & DOWNSPOUTS, TYP.
PRE-FINISHED METAL WALL PANEL
BY PEMB MANUFACTURER, TYP.
PRE-FINISHED OVERHEAD
COILING DOOR, TYP.
SPRAY FOAM INSULATION WITH
THERMAL BARRIER
PRE-FINISHED METAL WALL
PANEL TO 8'-0" A.F.F.
PRE-FINISHED
METAL
GUTTER &
DOWNSPOUTS, TYP.
PRE-FINISHED METAL ROOF PANELS
BY PEMB MANUFACTURER, TYP.
SPRAY FOAM INSULATION WITH
THERMAL BARRIER
PRE-FINISHED METAL ROOF PANELS
BY PEMB MANUFACTURER, TYP.
PRE-FINISHED METAL WALL PANEL
BY PEMB MANUFACTURER, TYP.
SUSPENDED GYPSUM CEILING
10'-0" A.F.F., PAINTED TYP.
METAL DOOR &
METAL FRAME
(PAINTED)
A.502
Sim O.H.
A.502
A.502
B.O. WINDOW
120' - 0"
B.O. HIGH WINDOW
126' - 0"
102A
102C
112A
BAY 2
J.C.
SYSTEMS
ELECT.
GEN.
MAINT/STRG.
5" CONC. SLAB ON
VAPOR BARRIER ON
4" GRAVEL BASE ON
SUB BASE. RE: S.200
PEMB ROOF
INSULATION W/ LINER
FINISH FLOOR
100' - 0"
EAVE
130' - 0"
RIDGE
136' - 9"
LOW EAVE
118' - 4"
A.501
PRE-FINISHED METAL ROOF PANELS
BY PEMB MANUFACTURER, TYP.
PRE-FINISHED METAL
WALL PANEL
BY PEMB
MANUFACTURER, TYP.
SPRAY FOAM INSULATION WITH
THERMAL BARRIER
PRE-FINISHED METAL
GUTTER & DOWNSPOUTS, TYP.
PRE-FINISHED METAL ROOF PANELS
BY PEMB MANUFACTURER, TYP.
PRE-FINISHED METAL
ROOF PANELS BY PEMB
MANUFACTURER, TYP.
PRE-FINISHED METAL
GUTTER & DOWNSPOUTS, TYP.
PRE-FINISHED METAL WALL
PANEL BY PEMB
MANUFACTURER, TYP.
PRE-FINISHED OVERHEAD
COILING DOOR, TYP.
PRE-FINISHED METAL WALL
PANEL TO 8'-0" A.F.F.
METAL DOOR &
METAL FRAME (PAINTED)
RIGID FRAME BY PEMB
MANUFACTURER.
A.502
B.O. WINDOW
120' - 0"
B.O. HIGH WINDOW
126' - 0"
BAY 4
104102C
5" CONC. SLAB ON
VAPOR BARRIER ON
4" GRAVEL BASE ON
SUB BASE. RE: S.200
PAVING. RE: CIVIL
A.502
Sim
PEMB ROOF
INSULATION W/ LINER
DESIGNED
WORK ORDER NO.
DRAWN
OFFICE OF
ISSUED BY DATE:
PREPARED BY
REV DATE
APPROVED BY
DESCRIPTION APP'DCHECK
OF
ADD
DAP
2020-042069
REVIEWED BY
DRAWING NO.
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FACILITY MANAGEMENT
AMP-400
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
MSTB FACILITY
SMALL ARCHITECTS HAROLD STONG
100% FOR CONSTRUCTION SUBMISSION
1 3/18/22 RESPONSE TO 100% REVIEW COMMENTS
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a
"need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
CONTRACT No. 6973GH-21-D-000044
BUILDING SECTIONS
A.501
November 23, 2022
31 75
1/8" = 1'-0"A.501
1 BUILDING SECTION 1 1/8" = 1'-0"A.501
2 BUILDING SECTION 4
1/8" = 1'-0"A.501
3 BUILDING SECTION 3
1/8" = 1'-0"A.501
4 BUILDING SECTION 2
FINISH FLOOR
100' - 0"
A.602
Sim
A.602
Sim
6" CONC. FILLED BOLLARD
18"
TYP.
SLAB ON GRADE
A.702
A.702
BAY 4
FINISH FLOOR
100' - 0"
EAVE
130' - 0"
A.601
Sim
A.601
Sim
A.602
Sim
O.H.
O.H.
A.602
Sim
A.702
A.F.F
18"
TYP.
B.O. WINDOW
120' - 0"
BAY 4
FINISH FLOOR
100' - 0"
LOW EAVE
118' - 4"
A.702
Sim
18"
TYP.
A.702
Sim
GEN.
MAINT/STRG.
FINISH FLOOR
100' - 0"
RIDGE
136' - 9"
A.602
Sim
A.602
Sim
A.601
Sim
A.601
SimO.H.
O.H.
A.702
Sim
A.702
Sim
18"
TYP.
B.O. HIGH WINDOW
126' - 0"
ARCHITECTURAL
STANDING SEAM
METAL ROOF PANELS
BAY 1
FINISH FLOOR
100' - 0"
RIDGE
136' - 9"
A.602
Sim
A.602
Sim
A.702
A.702
A.702
Sim
B.O. HIGH WINDOW
126' - 0"
J.C.
BAY 2
DESIGNED
WORK ORDER NO.
DRAWN
OFFICE OF
ISSUED BY DATE:
PREPARED BY
REV DATE
APPROVED BY
DESCRIPTION APP'DCHECK
OF
ADD
DAP
2020-042069
REVIEWED BY
DRAWING NO.
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FACILITY MANAGEMENT
AMP-400
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
MSTB FACILITY
SMALL ARCHITECTS HAROLD STONG
100% FOR CONSTRUCTION SUBMISSION
1 3/18/22 RESPONSE TO 100% REVIEW COMMENTS
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a
"need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
CONTRACT No. 6973GH-21-D-000044
WALL SECTIONS
A.502
November 23, 2022
18 751/2" = 1'-0"A.502
1 WALL SECTION 1
1/2" = 1'-0"A.502
4 WALL SECTION 4
1/2" = 1'-0"A.502
5 WALL SECTION 5
1/2" = 1'-0"A.502
3 WALL SECTION 3
ARCHITECTURAL
STANDING SEAM
METAL ROOF PANELS
ARCHITECTURAL STANDING
SEAM METAL ROOF PANELS
PEMB FRAME
STEEL PURLIN
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER
ARCHITECTURAL STANDING
SEAM METAL ROOF PANELS
LIGHT FIXTURE, RE:
ELECTRICAL
WINDOW, RE: A.603
ARCHITECTURAL
STANDING SEAM
METAL ROOF PANELS
STEEL PURLIN
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER PEMB FRAME
PRE-FINISHED METAL
WALL PANEL, TYP.
(COLOR TBD.)
WALL MOUNTED FIRE
EXTINGUISHER
SLAB ON GRADE
1/2" = 1'-0"A.502
2 WALL SECTION 2
PEMB FRAME
ARCHITECTURAL STANDING
SEAM METAL ROOF PANELS
PEMB FRAME
PEMB FRAME
PEMB FRAME
METAL SYUD WALL
WITH GYPSUM WALL
BOARD FINSIH
(PAINTED) RE:
WALL TYPES
RUBBER BASE COVE,
RE: SCHEDULE
SUSPENDED
GYPSUM CEILING,
(PAINTED) RE:
CEILING PLAN
CONC. FOOTING, RE: STRUCTURAL
CONC. FOOTING,
RE: STRUCTURAL
STEEL PURLIN
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER
(BEYOND)
OPEN
SLAB ON GRADE
PRE-FINISHED METAL
WALL PANEL, TYP.
(COLOR TBD.)
PRE-FINISHED METAL
WALL PANEL, TYP.
(COLOR TBD.)
PRE-FINISHED METAL
WALL PANEL, TYP.
(COLOR TBD.)VF-2 (BEYOND, RE:
MECHANICAL
PRE-FINISHED PEMB
CLOSURE TRIM,
COLOR TBD
PRE-FINISHED METAL
GUTTER AND
DOWNSPOUTS, COLOR
TBD
PRE-FINISHED METAL
GUTTER AND
DOWNSPOUTS, COLOR
TBD
LIGHT FIXTURE, RE:
ELECTRICAL
PRE-FINISHED METAL
WALL PANEL, TYP.
(COLOR TBD.)
LIGHT FIXTURE, RE:
ELECTRICAL
O.H. DOOR, RE:
SCHEDULE
6" CONC. FILLED
BOLLARD
CONC. SPLASH
BLOCK (BEYOND)
ARCHITECTURAL STANDING
SEAM METAL ROOF PANELS
O.H. CRANE
FRAME (BEYOND)
RE: PLAN
WALL MOUNTED FIRE
EXTINGUISHER
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER
(BEYOND)
SPRAY FOAM INSULATION
WITH THERMAL BARRIER
(BEYOND)
STEEL PURLIN
PRE-FINISHED METAL
GUTTER AND
DOWNSPOUTS, COLOR
TBD
6" CONC. FILLED
BOLLARD
CONC. FOOTING,
RE: STRUCTURAL
CONC. FOOTING,
RE: STRUCTURAL
6" CONC. FILLED
BOLLARD
STEEL PURLIN
PRE-FINISHED
METAL WALL
PANEL AND FURR-
OUT, COLOR TBD
PRE-FINISHED
METAL WALL
PANEL AND FURR-
OUT, COLOR TBD
O.H. CRANE
FRAME (BEYOND)
RE: PLAN
O.H. CRANE
FRAME BASE
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER
MOP SINK, RE
MECHANICAL
O.H.
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER
O.H. DOOR, RE:
SCHEDULE
O.H. DOOR, HOUSING, RE:
MANUFACTURER
PEMB ROOF
INSULATION W/
LINER
PEMB ROOF
INSULATION
W/ LINER
PEMB ROOF
INSULATION
PEMB ROOF
INSULATION W/
LINER
PEMB ROOF
INSULATION W/
LINER
PEMB ROOF
INSULATION
W/ LINER
PRE-FINISHED METAL PANEL TO 8'-0"
A.F.F. AT INTERIOR (COLOR TBD)
CONC. SLAB ON SPECIFIED BASE,
RE: STRUCTURAL
STEEL RE-INFORCING,
RE: STRUCTURAL
PRE-FINISHED METAL PANEL (COLOR
TBD)
METAL STUD FRAMING
NOTCH CONCRETE,
CONTRACTOR COORDINATE
WITH METAL PEMB ERECTOR
FINISHED GRADE, RE: CIVIL
CONC. FOOTING, RE: STRUCTURAL
DRAWING FOR FOUNDATION DETAIL
PEMB STEEL FRAME
PRE-FINISHED METAL
WALL PANEL (COLOR
TBD)
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER
PEMB PRE-FINISHED
METAL CLOSURE
TRIM (COLOR TBD)
INSIDE CLOSURE,
TAPED TOP AND
BOTTOM OF PANEL
VF-2 (BEYOND), RE:
MECHANICAL
METAL ROOF PANEL,
TYP. COLOR: BRONZE
PEMB STEEL PURLIN
PEMB STEEL ANGLE
PEMB ROOF
INSULATION W/
LINER
PEMB STEEL
FRAME (BEYOND)
PEMB EAVE STRUT
STEEL PURLIN
PRE-FINISHED METAL
WALL PANEL (COLOR
TBD)
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER
STEEL PURLIN
METAL ROOF PANEL, TYP.
COLOR: BRONZE
PEMB CLOSURE
METAL
INSIDE CLOSURE,
TAPED TOP AND
BOTTOM OF PANEL
PEMB ROOF
INSUATION W/ LINER
STEEL PURLIN
PEMB FRAME
(BEYOND)
METAL ROOF PANEL, TYP.
COLOR: BRONZE
INSIDE CLOSURE
TAPE
METAL GUTTER AND DOWN
SPOUTS, (PAINTED) TYP.
COLOR: COBBLE BROWN
(SW#6082)
PRE-FINISHED
METAL WALL PANEL
(COLOR TBD)
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER
STEEL PURLIN
PRE-FINISHED GUTTER
CLIP, 24" O.C.
PEMB ROOF
INSULATION
W/LINER
STEEL PURLIN
PEMB FRAME
(BEYOND)
METAL ROOF PANEL,
TYP. COLOR: BRONZE
INSIDE CLOSURE
TAPE
PRE-FINISHED
METAL WALL PANEL
(COLOR TBD)
PRE-FINISHED
METAL WALL PANEL
(COLOR TBD)
SPRAY FOAM
INSULATION WITH
THERMAL BARRIER
PEMB ROOF
INSULATION W/
LINER
PRE-FINISHED METAL
WALL PANEL (BEYOND)
5/8" GYPSUM, WALL BOARD
(PAINTED) (BEYOND)
RUBBER BASE COVE (BEYOND)
RE: SCHEDULE
PEMB STEEL COLUMN
STEEL RE-INFORCING, RE: STRUCTURAL
CONC. SLAB ON SPECIFIED BASE,
RE: STRUCURAL
CONC. FOOTING, RE:
STRUCTURAL DRAWING FOR
FOUNDATION DETAIL
DESIGNED
WORK ORDER NO.
DRAWN
OFFICE OF
ISSUED BY DATE:
PREPARED BY
REV DATE
APPROVED BY
DESCRIPTION APP'DCHECK
OF
ADD
DAP
2020-042069
REVIEWED BY
DRAWING NO.
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FACILITY MANAGEMENT
AMP-400
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
MSTB FACILITY
SMALL ARCHITECTS HAROLD STONG
100% FOR CONSTRUCTION SUBMISSION
1 3/18/22 RESPONSE TO 100% REVIEW COMMENTS
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a
"need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
CONTRACT No. 6973GH-21-D-000044
SECTION DETAILS
A.702
November 23, 2022
36 75
1 1/2" = 1'-0"A.702
1 DETAIL SECTION - CONC. FOOTING
1 1/2" = 1'-0"A.702
2 DETAIL SECTION - LOWER RAKE
1 1/2" = 1'-0"A.702
3 DETAIL SECTION - HIGH RIDGE
1 1/2" = 1'-0"A.702
4 DETAIL SECTION - EAVE & GUTTER
1 1/2" = 1'-0"A.702
6 DETAIL SECTION - LOW EVE
1 1/2" = 1'-0"A.702
DETAIL SECTION - MID-SLAB
FOOTING
GENERAL NOTES:
1. ROOF PANLE COLOR TO BE CHOSEN FROM MANUFACTURER'S STANDARD COLOR SELECTION.
2. PAINTED METAL (DOORS, WINDOW FRAMES, EXPOSED STEEL STRUCTURE) COLOR: COBBLE BROWN (SW#6082).
OWNER MAY CHOOSE ALTERNATE COLOR FROM SHERWIN WILLIAMS COLOR SELECTIONS
3. WALL PANEL COLOR BE CHOSEN FROM MANUFACTURER'S STANDARD COLOR SELECTION.
4. METAL BUILDING TRIM COLOR TO BE CHOSEN FROM STANDARD MANUFACTURER'S COLOR SELECTION.
5. MECHANICAL LOUVER COLOR TO BE CHOSEN FROM MANUFACTURER'S STANDARD COLRO SELECTION.
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.
CONTRACT No. 6973GH-21-D-000044
P:
\2
\E
1.
dw g, 1/
/2
:2 3:
A
M , d na sa lro ad
D
W G
To P
D F-
X2
2.
pc
W.O. 2020-042069 / FAA-MMAC
Mobile Systems Test Bed Facility
(MSTB)
10.14.00 - 1 Signage
SECTION 10.14.00
SIGNAGE
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Room and door signs.
1.02 REFERENCE STANDARDS
A. 36 CFR 1191 - Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines current edition.
B. ADA Standards - Americans with Disabilities Act (ADA) Standards for Accessible Design 2010.
C. ICC A117.1 - Accessible and Usable Buildings and Facilities 2009.
1.03 SUBMITTALS
A. See Section 01.30.00 - Administrative Requirements, for submittal procedures.
B. Product Data: Manufacturer's printed product literature for each type of sign, indicating sign styles, font, foreground and background colors, locations, overall dimensions of each sign.
C. Signage Schedule: Provide information sufficient to completely define each sign for fabrication, including room number, room name, other text to be applied, sign and letter sizes, fonts, and colors.
D. Manufacturer's Qualification Statement.
1.04 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with minimum three years of documented experience.
1.05 DELIVERY, STORAGE, AND HANDLING
A. Package signs as required to prevent damage before installation.
B. Package room and door signs in sequential order of installation, labeled by floor or building.
C. Store tape adhesive at normal room temperature.
1.06 FIELD CONDITIONS
A. Maintain this minimum temperature during and after installation of signs.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Flat Signs:
1. Best Sign Systems, Inc : www.bestsigns.com/#sle.
2. FASTSIGNS ; Rowmark Brand : www.fastsigns.com/#sle.
3. Substitutions: See Section 01.60.00 - Product Requirements.
2.02 SIGNAGE APPLICATIONS
A. Accessibility Compliance: Signs are required to comply with ADA Standards and ICC A117.1 , unless otherwise indicated; in the event of conflicting requirements, comply with the most comprehensive and specific requirements.
B. Room and Door Signs: Provide a sign for every doorway, whether it has a door or not, not including corridors, lobbies, and similar open areas.
1. Sign Type 1: See FAA/MMAC Panel Signage Criteria following this section.
2. Sign Type 2: Flat aluminum sign with reflective panel media as specified.
a. Provide "tactile" signage, with letters raised minimum 1/32 inch (0.8 mm) and Grade II braille.
b. Character Height: 2 inch (50 mm) .
c. Sign Height: 7 inches (175 mm) , unless otherwise indicated.
W.O. 2020-042069 / FAA-MMAC
Mobile Systems Test Bed Facility
(MSTB)
10.14.00 - 2 Signage
3. Fire Riser Room: Identify with text "FIRE RISER ROOM" in contrasting color to background .
4. Service Rooms: Identify with room names and numbers to be determined later, not those indicated on drawings.
5. Rest Rooms: Identify with pictograms, the names "MEN" and "WOMEN", room numbers to be determined later, and braille.
2.03 SIGN TYPES
A. Flat Signs: Signage media without frame.
1. Edges: Square.
2. Corners: Square.
3. Wall Mounting of One-Sided Signs: Concealed or exposed screws .
B. Color and Font: Unless otherwise indicated:
1. Character Font: Helvetica, Arial, or other sans serif font.
2. Character Case: Upper case only.
3. Background Color: Red .
4. Character Color: White color as selected by Owner.
2.04 ACCESSORIES
A. Exposed Screws: Chrome plated.
B. Tape Adhesive: Double sided tape, permanent adhesive.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that substrate surfaces are ready to receive work.
3.02 INSTALLATION
A. Install in accordance with manufacturer's instructions.
B. Install neatly, with horizontal edges level.
C. Protect from damage until Date of Substantial Completion; repair or replace damaged items.
END OF SECTION
FAA/MMAC Panel Signage Criteria
1. Sign material is plastic, 1/8" thick, with 1/2" radius corners, and no borders.
2. All versions of sign types 1, 2 and 3 are 8" square; refer to sign type and installation details for additional dimensional information.
3. Colors must be an integral part of the plastic or applied to the back surface of a translucent panel; painted sign faces are not acceptable without an approved request for substitution, subject to construction contract.
4. Submittal requirements include shop drawings, samples of each sign type, and samples of available/requested colors for review and/or selection.
5. The FAA will provide a sign location map and a sign schedule shortly before substantial completion of the construction contract; do not expect signage or CCMS room numbers to match contract documents.
6. Sign panels must contrast with the substrate, and characters/pictograms
(typically white) must contrast with the sign panels.
7. Characters and pictograms must be raised in accordance with current
ADA standards to accommodate tactile examination.
8. The standard method of attachment is two 6" lengths of double sided foam tape, positioned horizontally, 1/4" to 1/2" clear from the top and bottom edges of the panel and 1/2" to 1" clear from the sides of the panel.
Exception: Where a base plate is required, the foam tape will be installed across the full width of the base plate and flush to the top and bottom edges of the base plate.
9. Alternative attachment:
a. Where the substrate texture is relatively planar, but too rough to accommodate foam tape, install a 6" square base plate
(plastic or painted metal) attached to the substrate with a countersunk screw 1/2" to 3/4" from each corner of the plate.
The screws/inserts must be appropriate for the substrate(s) and the base plate must be centered on the intended location of the panel sign. Conceal all fasteners.
b. Where the substrate is very rough (e.g., split-face CMU), the base plate must be installed with stand-offs; refer to sample detail and coordinate with FAA COR. Conceal all fasteners.
c. Where a substrate is transparent, install a blank sign panel on the opposite side of the substrate, aligned with the sign panel.
10. These criteria are in strict accordance with current ADA standards and FAA/MMAC guidelines - deviations are not recommended.
11. Room names shall be limited to the following:
BOILER COMM. CONFERENCE
ELECTRICAL EQUIPMENT MECHANICAL
MEN RESTROOM WOMEN
JANITOR STAIRS STORAGE
12. A sign-positioning template is recommended for accurate installation.
13. Available local vendors include, but are not limited to:
Architectural Sign & Graphics, 839 Industrial Drive, Yukon, 354-8829 and; FastSigns, 1401 S. Meridian Ave., OKC, 943-3278.
Refer to Rowmark brand for plastic selection.
Irregular substrate
(split-face CMU)
Panel sign
Foam tape
Countersunk
(CSK) screw
Cylindrical stand-off
Base plate
3/8" clear, maximum
SAMPLE DETAIL
Vertical Section
Alternative Attachment
(typ. nylon cut-to-fit)
Foam tape
April 8, 2019
RESTROOM
SIGN TYPE
2M, 2W or 2R
SIGN TYPE
1A BENEATH
RESTROOM
SIGNS, TYP.
WOMENMEN
RESTROOM
STORAGE
GRADE 2
BRAILLE
ROOM
NUMBER
1A
ROOM
NAME
GRADE 2
BRAILLE
GRADE 2
BRAILLE
ROOM
NUMBER
1B
2M 2W
2R
PICTOGRAMS VARY BY
RESTROOM TYPE;
REFER TO SCHEDULE.
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
PER ADA STANDARDS
"MEN", "WOMEN" OR
"RESTROOM" PER SCHEDULE
GRADE 2
BRAILLE
IN CASE
OF FIRE
DO NOT USE
ELEVATORS
USE STAIRS
AUTOMATIC
DOOR
CAUTION
4A 4B
GRAPHIC
SYMBOL:
FIRE
TEXT: 5/8" TALL
GRAPHIC
SYMBOL:
EXIT STAIR
GRADE 2
BRAILLE
FAA/MMAC Panel Signage Criteria
April 8, 2019
Sign Types and Features
STRIKE/LATCH SIDE
OF DOOR FRAME
PLACE ON CALL BUTTON
SIDE OF ELEVATOR DOOR
AUTOMATIC DOOR DECALS:
6" DIAMETER VINYL
EACH LEAF, BOTH SIDES
EACH LEAF, ON
APPROACH SIDE
WHITE
YELLOW
YELLOW
BLACK
BLACK
GREEN
Sign Location Information
FOAM TAPE
FOAM TAPE
SIGN TYPE
1A, 1B or 3
STRIKE/LATCH SIDE
OF DOOR FRAME
END OF SECTION