6973GH-20-R-00145: Rehabilitate the ALB VOR roof located in Albany, NY
Revisions to the Construction Drawings as of 8/27/2020
1. Reference Contract drawing ALB-1004541-A008, detail 3/008 and “GFM Monitor Antenna Support Assembly” table. The Contractor shall assemble and secure item 6 to item 7 by tack welding or peening the steel rod threads.
1. Reference Contract drawing ALB-1004541-D001, detail 3/008 note 5, second sentence. Replace “Flashgrade caulk (Truco #7174 or equal) with “pressure washable epoxy, approved by roofing manufacturer. Epoxy shall be a submittal item.”