About this file

SOW Attachment 3 Site Surveys 2 of 3 (pdf)

View the file

Other files

File Type Posted
Attachment 09-2015-5753 Rev. 11 HutchinsonKS.pdf PDF
Attachment 33-2015-4249 Rev. 11 ClearfieldPA.pdf PDF
Attachment 34-2015-4647 Rev. 12 JoeltonTN.pdf PDF
Attachment 25-2015-4471 Rev. 13 MariettaGA.pdf PDF
Attachment 31-2015-4313 Rev. 11 BinnsHallVA.pdf PDF
Attachment 12-2015-5597 Rev. 11 FallonNV.pdf PDF
Attachment 30-2015-4707 Rev. 11 LynchKY.pdf PDF
Attachment 22-2015-5237 Rev. 11 RogersTX.pdf PDF
Attachment 16-2015-4927 Rev. 11 HoriconWI.pdf PDF
Attachment 17-2015-5145 Rev. 9 TexarkanaAR.pdf PDF
Attachment 26-2015-5471 Rev. 8 SeligmanAZ.pdf PDF
Attachment 13-2015-5413 Rev. 9 LuskWY.pdf PDF
Attachment 06-2015-5005 Rev. 9 OmahaNE.pdf PDF
Attachment 41-2015-5409 Rev. 9 RockSpringsWY.pdf PDF
SOW Attachment 2 Site Surveys 1 of 3.pdf PDF
Attachment 18-2015-4387 Rev. 11 MaidenNC.pdf PDF
Attachment 38-2015-5095 Rev. 11 KirksvilleMO.pdf PDF
Attachment 29-2015-4727 Rev. 9 BrecksvilleOH.pdf PDF
Attachment 23-2015-5339 Rev. 9 OskaloosaKS.pdf PDF
Attachment 36-2015-5451 Rev. 9 MesaRicaNM.pdf PDF
Attachment 28-2015-4987 Rev. 11 ArlingtonIA.pdf PDF
Attachment 08-2015-5451 Rev. 9 GallupNM.pdf PDF
Attachment 21-2015-4673 Rev. 10 ByhaliaMS.pdf PDF
Attachment 42-Schedule B monitoring.pdf PDF
16. SIR 6973GH-19-R-00236 Amendment 0001 Asbestos Abatement Monitoring.pdf PDF
Attachment 19-2015-5373 Rev. 11 GettysburgSD.pdf PDF
Attachment 05-2015-5027 Rev. 9 HannaCityIL.pdf PDF
Attachment 04-2015-5423 Rev. 11 GrandJunctionCO.pdf PDF
SIR 6973GH-19-R-00236 Asbestos Abatement Monitoring.pdf PDF
Attachment 10-2015-5535 Rev. 9 SeattleWA.pdf PDF
Attachment 37-2015-5357 Rev. 9 NorthPlatteNE.pdf PDF
Attachment 14-2015-4729 Rev. 11 LondonOH.pdf PDF
Attachment 01-STATEMENT OF WORK MONITORING CIH.pdf PDF
SOW Attachment 3 Site Surveys 2 of 3.pdf PDF
Attachment 35-2015-5823 Rev. 10 NewportMS.pdf PDF
Attachment 02-Experience and Past Performance Information Form.pdf PDF
Attachment 32-2015-5345 Rev. 9 GardenCityKS.pdf PDF
SOW Attachment 1 Site list and Coordinates.pdf PDF
Attachment 07-2015-5517 Rev. 9 AshtonID.pdf PDF
Attachment 27-2015-4311 Rev. 9 BedfordVA.pdf PDF
Attachment 24-2015-5433 Rev. 13 TrinidadCO.pdf PDF
Attachment 15-2015-5513 Rev. 9 CascadeID.pdf PDF
Attachment 11-2015-5601 Rev. 9 BattleMountainNV.pdf PDF
Attachment 20-2015-5443 Rev. 8 WestMesaNM.pdf PDF
Attachment 40-2015-5687 Rev. 9 KenaiAK.pdf PDF
Attachment 03-2015-5593 Rev. 11 AngelPeakNV.pdf PDF
Attachment 39-2015-4465 Rev. 10 LincolntonGA.pdf PDF
SIR QUESTIONS & ANSWERS.pdf PDF
SOW Attachment 4 Site Surveys 3 of 3.pdf PDF
Attachment 13-2015-5413 Rev. 9 LuskWY.pdf PDF
Show 40 more

Latest 50 of 95 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 Suspect Asbestos-Containing Materials

The following table contains a list of 36 sampled accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number 9" x 9" Green Floor Tile Under Green Equipment Main Building L-1A Black Mastic Under Green Equipment Main Building L-1B 9" x 9" Green Floor Tile Under Tan Equipment Main Building L-2A Black Mastic Under Tan Equipment Main Building L-2B 9" x 9" Green Floor Tile Under Tan Equipment Main Building L-3A Black Mastic Under Tan Equipment Main Building L-3B 2' x 4' Ceiling tiles painted white Main Building Bathroom L-4 2' x 4' Ceiling tiles painted white Main Building Bathroom L-5 2' x 4' Ceiling tiles painted white Main Building Bathroom L-6 White window compound Outside Office Window L-7 White compound on cylindrical duct CO Main Building beside BCN & ISM equipment L-8 White 2' x 2' Ceiling tile Main Building-replacement(s) L-9 12" x 12" stone splotched floor tile Main Building L-10A Yellow Mastic Main Building L-10B

QWO ARSR

LONDON OHIO

BUILDING MATERIALS

Material Material Sample Location Sample Number

12" x 12" stone splotched floor tile Main Building L-11A Yellow Mastic Main Building L-11B 12" x 12" stone splotched floor tile Main Building L-12A Yellow Mastic Main Building L-12B 12" x 12" Grey Floor Tile Main Building-Office L-13A Yellow Mastic Main Building-Office L-13B 12" x 12" Grey Floor Tile Main Building-Office L-14A Yellow Mastic Main Building-Office L-14B 12" x 12" Grey Floor Tile Main Building-Office L-15A Yellow Mastic Main Building-Office L-15B 9" x 9" Green Floor Tile Out Building L-16A Black Mastic Out Building L-16B 9" x 9" Green Floor Tile Out Building L-17A Black Mastic Out Building L-17B 9" x 9" Green Floor Tile Out Building L-18A Black Mastic Out Building L-18B Wall Board C-Wall Out Building L-19 Wall Board D-Wall Out Building L-20 Wall Board D-Wall Out Building L-21 Window Glazing Compound Out Building L-22 Bitumen Roofing Main Blding Roof L-23 Bitumen Roofing Main Blding Roof L-24 Bitumen Roofing Main Blding Roof L-25

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

TABLE 2: ASBESTOS CONTAINING MATERIALS

Sample Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

L-1A 9" X 9" Green Floor Tile (M)

Under Green Equipment Main Building

No 20 SF Good 1 2% Chrysotile

L-1B Black Mastic (M) Under Green Equipment Main Building

No 20 SF Good 1 3% Chrysotile

L-2A 9" X 9" Green Floor Tile (M)

Under Tan Equipment Main Building

No 12 SF Good 1 2% Chrysotile

L-2B Black Mastic (M) Under Tan Equipment Main Building

No 12 SF Good 1 3% Chrysotile

L-3A 9" X 9" Green Floor Tile (M)

Under Tan Equipment Main Building

No 12 SF Good 1 3% Chrysotile

L-3B Black Mastic (M) Under Tan Equipment Main Building

No 12 SF Good 1 2% Chrysotile

L-8 White compound on cylindrical duct

CO (M)

Main Building beside BCN & ISM equipment

No 1 SF Good 1 2% Chrysotile

L-16A 9" X 9" Green Floor Tile (M)

Out Building No 200 SF Good 1 3% Chrysotile

L-17A 9" X 9" Green Floor Tile (M)

Out Building No 200 SF Good 1 3% Chrysotile

L-18A 9" X 9" Green Floor Tile (M)

Out Building No 200 SF Good 1 3% Chrysotile

SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM PACM= Presumed asbestos containing material

Note 1: The 9" x 9" floor tile is located under existing equipment.

Note 2: The bitumen roofing on the main building was tested and found to contain <1% chrysotile.

BUILDING SCHEMATICS

QWO London, OH

ARSR ½ building additional storage buildings

The following table contains a list of eleven (11) sampled accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number Epoxy Floor Coating, Grey with Black Equipment Room ER-0329-

01A Epoxy Floor Coating, Grey with Black Equipment Room ER-0329-

01B Epoxy Floor Coating, Grey with Black Equipment Room ER-0329-

01C White Fissured Ceiling Panels Equipment Room ER-0329-

02A White Fissured Ceiling Panels Equipment Room ER-0329-

02B

ATL ARSR

MARRIETA GEORGIA

White Fissured Ceiling Panels Equipment Room ER-0329- 02C

Window Glazing, White Exterior of Main Building- SW MB-0329- 03A

Window Glazing, White Exterior of Main Building- NW MB-0329- 03B

Window Glazing, White Exterior of Main Building- NW MB-0329- 03C

Door Caulking, White Exterior of Main Building-Main Entrance MB-0329- 04A

Door Caulking, White Exterior of Main Building-Electrical Room MB-0329- 04B

Door Caulking, White Exterior of Main Building-South Central Entrance MB-0329- 04C

Vent Hood Caulking, Grey Exterior-South Exhaust Vent MB-0329- 05A

Vent Hood Caulking, Grey Exterior-North Central Exhaust Vent MB-0329- 05B

Vent Hood Caulking, Grey Exterior-NW Exhaust Vent MB-0329- 05C

Exhaust Fan Hood Caulking, Grey Exterior-SE Side of Building MB-0329- 06A

Exhaust Fan Hood Caulking, Grey Exterior-SE Side of Building MB-0329- 06B

Exhaust Fan Hood Caulking, Grey Exterior-SE Side of Building MB-0329- 06C

Beige Vinyl Cove Base with Creme Mastic Operators Office MB-0329- 07A

Beige Vinyl Cove Base with Creme Mastic Break Room MB-0329- 07B

Beige Vinyl Cove Base with Creme Mastic Equipment Room MB-0329- 07C

Fire Stop Caulking, Grey NW Office MB-0329- 08A

Fire Stop Caulking, Grey NW Office MB-0329- 08B

Fire Stop Caulking, Grey NW Office MB-0329- 08C

12" x 12" Beige and Black Vinyl Floor Tile with Black Mastic

Main Equipment Room-Inside West Data Storage Cabinet

MB-0329-

09A

12" x 12" Beige & Black Vinyl Floor Tile with Black Mastic

Main Equipment Room-Inside West Data Storage Cabinet

MB-0329-

09B

12" x 12" Tan & Beige Vinyl Floor Tile with Black Mastic

Operators Office MB-0329- 10A

12" x 12" Tan & Beige Vinyl Floor Tile with Yellow Mastic

Break Room MB-0329- 10B

4' x 2' White Fissured Ceiling Panel Main Equipment Room-West MB-0329- 11A

4' x 2' White Fissured Ceiling Panel Main Equipment Room-Central MB-0329- 11B

4' x 2' White Fissured Ceiling Panel Main Equipment Room-East MB-0329- 11C

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

TABLE 2: ASBESTOS CONTAINING MATERIALS

Sample Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

MB-0329-

05A

Vent Hood Caulking, Grey (M)

Exterior-North Central Exhaust Vent

N.F. II 32 LF Good 1 4% Chrysotile

MB-0329-

05B

Vent Hood Caulking, Grey (M)

Exterior-North Central Exhaust Vent

N.F. II 32 LF Good 1 4% Chrysotile

MB-0329-

05C

Vent Hood Caulking, Grey (M)

Exterior-NW Exhaust Vent

N.F. II 32 LF Good 1 4% Chrysotile

MB-0329-

06A

Exhaust Fan Hood Caulking, Grey (M)

Exterior-South Side of Building

N.F. II 28 LF Good 1 5% Chrysotile

MB-0329-

06A

Exhaust Fan Hood Caulking, Grey (M)

Exterior-South Side of Building

N.F. II 28 LF Good 1 5% Chrysotile

MB-0329-

06A

Exhaust Fan Hood Caulking, Grey (M)

Exterior-North Side of Building

N.F. II 28 LF Good 1 5% Chrysotile

MB-0329-

09A

Black Mastic associated with 12" x 12" Beige & Black Vinyl Floor Tile (M)

Main Equipment Room-Inside West Data Storage Cabinet

N.F. II 24 SF Good 1 Mastic: 3% Chrysotile

MB-0329-

09A

Black Mastic associated with 12" x 12" Beige & Black Vinyl Floor Tile (M)

Main Equipment Room-Inside West Data Storage Cabinet

N.F. II 24 SF Good 1 Mastic: 3% Chrysotile

SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM PACM= Presumed asbestos containing material

ATL Marietta, GA ARSR ½ building ~2000 sf

Asbestos Sample Location Drawing Red font indicates positive sample location

Blue font indicates negative sample location

The following table contains a list of 16 homogeneous areas with a total of 44 sampled accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number Caulk (white) Interior of dome wall M-1A, M-1B Caulk (grey) Interior of dome flooring joints M-2A, M-2B, M-2C

Caulk (grey) Interior of dome floor edge M-3A, M-3B, M-3C

Caulk (grey) Interior stairway M-4A, M-4B, M-4C

QBE ARSR

BEDFORD VIRGINIA

12"x12" Floor tile and mastic (off white with dashes)

Main building electric room and computer room M-5A, M-5B, M-5C

Cove base mastic (beige) Interior main building M-6A, M-6B

12"x12" Floor tile and mastic (off white with dashes)

Interior main building battery room M-7A, M-7B, M-7C

Cove base mastic (off white) Battery room M-8A, M-8B

2'x4' Ceiling tile (white with holes) Bathroom/offices M-9A, M-9B, M-9C

Drywall and joint compound Generator room M-10A, M-10B, M-10C

Caulk (red fire stop) Battery room M-11A, M-11B, M-11C

Caulk (beige) Exterior M-12A, M-12B, M-12C

Duct work coating Exterior M-13A, M-13B, M-13C

Caulk (white) Exterior filling pipe M-14A, M-14B

Roof tar (black) Exterior roof M-15A, M-15B, M-15C

Caulk (beige) Exterior storage building M-16A, M-16B, M-16C

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

TABLE 2: ASBESTOS CONTAINING MATERIALS

Sample Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

M-15A Roof tar, M Roof (patch on roof)

N.F. I 20 SF Fair 1 8% Chrysotile

M-15B Roof tar, M Roof (patch on roof)

N.F. I 20 SF Fair 1 5% chrysotile

SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM

QBE Bedford, VA ARSR 3 with generator and

2725 E. Millbrook Road, Suite 121 Raleigh, NC 27604

(919) 871-0999

SAMPLE LOCATION DRAWING

PROJECT NO: 204BS01749

REVIEWED BY:JC SCALE: NTS DATE: 04-2018

QBE ARSR

N37 31 02.0 W79 30 36.0

BEDFORD, VIRGINIA 24523

M-1A

Main Building

Tower

Storage Building

M-1B

M-2C

M-3C

M-4C

M-2A

M-2B

M-3B

M-3A

M-4B

M-4A

M-7C

M-5A

M-5B

M-5C

M-6A

M-6B

M-7A

M-7B

M-9A

M-8B

M-8A

M-9B

M-9C

M-10A

M-10B

M-10C

M-11A

M-11B

M-11C

M-12A

M-12B M-12C

M-13A M-13B

M-13C

M-14A

M-14B

M-15A

M-15B

M-15C

M-16A

M-16B M-16C

Sample Locations

Positive Sample Locations

2725 E. Millbrook Road, Suite 121 Raleigh, NC 27604

(919) 871-0999

ASBESTOS MATERIAL LOCATION

PROJECT NO: 204BS01749

REVIEWED BY:JC SCALE: NTS DATE: 04-2018

QBE ARSR

N37 31 02.0 W79 30 36.0

BEDFORD, VIRGINIA 24523

Main Building

M-15A

M-15B

= Represents approximate location of asbestos roof tar patch.

3.4 Suspect Asbestos-Containing Materials

The following table contains a list of 71 sampled accessible building materials suspected of containing asbestos:

QBZ ARSR

OSKALOOSA KANSAS

TABLE 1: SUSPECT BUILDING MATERIALS

Number Caulk - White Radome Walls QBZ-CK1

-01 Caulk - White Radome Walls QBZ-CK1

-02 Caulk - White Radome Walls QBZ-CK1

-03 Duct Sealant - Grey Radar Tower QBZ-DS1

-04 Duct Sealant - Grey Radar Tower QBZ-DS1

-05 Caulk - White Radar Tower QBZ-CK2

-06 Caulk - White Radar Tower QBZ-CK2

-07 Caulk - Off-White Radar Tower Base QBZ-CK3

-08 Caulk - Off-White Radar Tower Base QBZ-CK3

-09 Beam Coating - Black Radar Tower Base QBZ-BC1

-10 Beam Coating - Black Radar Tower Base QBZ-BC1

-11 Beam Coating - Black Radar Tower Base QBZ-BC1

-12 Caulk - Grey Exterior HVAC QBZ-CK4

-13 Caulk - Grey Exterior HVAC QBZ-CK4

-14 Roof Flashing Mastic - Black Main Building Roof Penetration QBZ-RF

M1-15 Roof Flashing Mastic - Black Main Building Roof Penetration QBZ-RF

M1-16 Duct Sealant - Grey/Tan Main Building Exterior QBZ-DS2

-17 Duct Sealant - Grey/Tan Main Building Exterior QBZ-DS2

-18 Duct Sealant - Black Main Building Exterior QBZ-DS3

-19 Duct Sealant - Black Main Building Exterior QBZ-DS3

-20 Duct Sealant - Grey Main Building Exterior QBZ-DS4

-21 Duct Sealant - Grey Main Building Exterior QBZ-DS4

-22 Ceiling Tile - 2' x 2' Pinholes & Gouges Equipment Room QBZ-CT1

-23 Ceiling Tile - 2' x 2' Pinholes & Gouges Equipment Room QBZ-CT1

-24 Surfacing Material - Off-White Storage Room 106/Former Generator Room QBZ-SM1

-25 Surfacing Material - Off-White Storage Room 106/Former Generator Room QBZ-SM1

-26 Surfacing Material - Off-White Storage Room 106/Former Generator Room QBZ-SM1

-27 Floor Tile - 12" x 12" Cream w/ Tan Streaks Equipment Room QBZ-FT1-

Floor Tile Mastic - Yellow Equipment Room (u. FT1) QBZ-FT1-

Floor Tile - 12" x 12" Cream w/ Tan Streaks Equipment Room QBZ-FT1-

Floor Tile Mastic - Yellow Equipment Room (u. FT1) QBZ-FT1-

Cove Base - 4" Light Tan Janitor's Closet QBZ-CB1 -30

Cove Base Adhesive - Yellow Janitor's Closet (u. CB1) QBZ-CB1 -30

Cove Base - 4" Light Tan Janitor's Closet QBZ-CB1 -31

Cove Base Adhesive - Yellow Janitor's Closet (u. CB1) QBZ-CB1 -31

Floor Tile - 12" x 12" Cream w/ Blue Streaks Equipment Room under Cabinets QBZ-FT2-

Floor Tile Mastic - Black Equipment Room under Cabinets (u. FT2) QBZ-FT2-

Floor Tile - 12" x 12" Cream w/ Blue Streaks Equipment Room under Cabinets QBZ-FT2-

Floor Tile Mastic - Black Equipment Room under Cabinets (u. FT2) QBZ-FT2-

Caulk - Off-White UPS/Generator Bldg. Base QBZ-CK5 -34

Caulk - Off-White UPS/Generator Bldg. Base QBZ-CK5 -35

Caulk - White Expansion Joint QBZ-CK6 -36

Caulk - White Expansion Joint QBZ-CK6 -37

Floor Tile - 12" x 12" Tan w/ Beige Streaks Break Room QBZ-FT3-

Floor Tile Mastic - Yellow Break Room QBZ-FT3-

Floor Tile - 12" x 12" Tan w/ Beige Streaks Break Room QBZ-FT3-

Floor Tile Mastic - Yellow Break Room QBZ-FT3-

Floor Tile - 12" x 12" Tan w/ Beige Streaks UPS Room QBZ-FT3-

Floor Tile Mastic - Yellow UPS Room QBZ-FT3-

Floor Tile - 12" x 12" Cream w/ Tan Streaks UPS Room QBZ-FT1-

Floor Tile Mastic - Tan UPS Room QBZ-FT1-

Floor Tile - 12" x 12" Cream w/ Red & Blue Streaks

UPS Room QBZ-FT4-

Floor Tile Mastic - Black UPS Room QBZ-FT4-

Floor Tile - 12" x 12" Cream w/ Red & Blue Streaks

UPS Room QBZ-FT4-

Floor Tile Mastic - Black UPS Room QBZ-FT4-

Ceiling Tile - 2' x 4' Textured UPS Room QBZ-CT2 -44

Ceiling Tile - 2' x 4' Textured UPS Room QBZ-CT2 -45

Cove Base - 4" Tan Generator Room QBZ-CB2 -46

Cove Base Adhesive - Yellow Generator Room QBZ-CB2 -46

Cove Base - 4" Tan Generator Room QBZ-CB2 -47

Cove Base Adhesive - Yellow Generator Room QBZ-CB2 -47

Caulk - Grey Main Building Base QBZ-CK7 -48

Caulk - Grey Main Building Base QBZ-CK7 -49

Joint Compound Restroom QBZ-DW 1-50

Drywall Tape Restroom QBZ-DW 1-50

Joint Compound Restroom QBZ-DW 1-50

Drywall Restroom QBZ-DW 1-50

Joint Compound Hallway QBZ-DW 1-51

Drywall Hallway QBZ-DW 1-51

Joint Compound Tech Ops Office QBZ-DW 1-52

Drywall Tech Ops Office QBZ-DW 1-52

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

TABLE 2: ASBESTOS CONTAINING MATERIALS

Sample Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

QBZ-BC1

-10,11,12

Beam Coating - Black (M)

Radar Tower Base N.F. II 48 SF Good 1 2% Chrysotile

QBZ-FT2-

32,33

Floor Tile Mastic - Black (u. FT2) (M)

Equipment Room under Cabinets

N.F. I 36 SF Good 1 5-8% Chrysotile

SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM

8246 Marshall Drive Lenexa, Kansas 66214

SITE SKETCH

DESIGNED BY: ATC SCALE: NTS

DRAWN BY: DG DATE: 5/16/18 FILE: SKETCH

REVIEWED BY: TJ

ASBESTOS SURVEY

PROJECT NO: 204BS01749 Air Route Surveillance Radar Shelter (ARSR) Site - QBZ 39.222222, -95.245833

Oskaloosa, Kansas 66054

Legend

03 = Negative Asbestos Sample Locations 05 = Positive or Assumed Asbestos Sample Locations

C

= Asbestos Containing Material Locations

08A

B

D

SITE SKETCH

DESIGNED BY: ATC SCALE: NTS

DRAWN BY: DG DATE: 5/16/18 FILE: SKETCH

REVIEWED BY: TJ

ASBESTOS SURVEY

PROJECT NO: 204BS01749 Air Route Surveillance Radar Shelter (ARSR) Site - QBZ 39.222222, -95.245833

Oskaloosa, Kansas 66054

Legend

46,47

03 = Negative Asbestos Sample Locations 05 = Positive or Assumed Asbestos Sample Locations

A

= Asbestos Containing Material Locations

04,05

06,07

44,45

C

BD

SITE SKETCH

DESIGNED BY: ATC SCALE: NTS

DRAWN BY: DG DATE: 5/16/18 FILE: SKETCH

REVIEWED BY: TJ

ASBESTOS SURVEY

PROJECT NO: 204BS01749 Air Route Surveillance Radar Shelter (ARSR) Site - QBZ 39.222222, -95.245833

Oskaloosa, Kansas 66054

Legend

03 = Negative Asbestos Sample Locations 05 = Positive or Assumed Asbestos Sample Locations

C 30,31

= Asbestos Containing Material Locations

25,26

17,18

21,2219,20

15,16

A

D B

28,29

32,33

38,39

The following table contains a list of 64 sampled accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number White Sealant Radar Dome QCK-01 White Sealant Radar Dome QCK-02 Yellow Insulation and Paper Backing Floor of Radar Dome QCK-03 White Sealant Exterior Base of Dome QCK-04 White Paint Exterior Base of Dome QCK-05 Black Tar Sealant Stairwell to Roof QCK-06 Grey Duct Sealant Exterior Mezzanine QCK-07 White Sealant Exterior Stairwell of Dome QCK-08 Blue Foam with Black Mastic Radar Dome QCK-09 White Sealant Metal Beams inside Dome QCK-010 Grey Sealant Exterior Mezzanine of Dome QCK-011 Black Sealant Roof of Main Building QCK-012 White Sealant Roof of Main Building-beneath Concrete Slabs QCK-013 White Membrane Roof of Main Building QCK-014

QCK ARSR

CASCADE IDAHO

White Sealant 4" Vent Pipe on Roof of Main Building QCK-015 Grey Sealant HVAC Ducting on Roof of Main Building QCK-016 2' x 4' Ceiling Panel with Mesh Layer Office Addition in Main Building QCK-017 12" x 12" White Vinyl Floor Tile with Yellow Mastic Office Addition in Main Building QCK-018 12" x 12" White Vinyl Floor Tile with Yellow Mastic Radar Equipment Room QCK-019 Green 9" x 9" Vinyl Floor Tile with Clear Mastic Radar Equipment Room QCK-020 4" Tan Vinyl Cove Base with Tan Mastic Office Addition in Main Building QCK-021 12" x 12" White Vinyl Floor Tile with Black Streaks and Mastic

Office Addition in Main Building QCK-022

4" Black Vinyl Cove Base with Tan Mastic Office Addition in Main Building QCK-023 Mortar between CMU Blocks Radar Equipment Room QCK-024 Grey Sealant Air Ducting in the Office Addition in Main Building QCK-025 1" x 1" Ceramic Tile Floor with Grey Grout and Mortar and Base Layer

Radar Equipment Room Restroom QCK-026

Exposed Beige Mastic CMU Block in Radar Equipment Room QCK-027 White/Green Paint CMU Block in Radiator Room QCK-028 Grey Coating Plywood Floor in Hallway to Living Quarters QCK-029 Grey Coating Plywood Floor in Hallway to Living Quarters QCK-030 Grey Coating Plywood Floor in Hallway to Living Quarters QCK-031 12" x 12" White Vinyl Floor Tile with Black Streaks and Black Mastic

Old Motor Generator Room QCK-032

12" x 12" White Vinyl Floor Tile with Black Streaks and Black Mastic

Old Motor Generator Room QCK-033

Burgundy Carpet with Leveling Compound/Mastic Old Motor Generator Room QCK-034 4" Pink Vinyl Cove Base with Mastic Office in Living Quarters QCK-035 4" Burgundy Vinyl Cove Base with Cream Mastic Living Room in Living Quarters QCK-036 Pebble Patterned Sheet Flooring with Mastic Kitchen in Living Quarters QCK-037 Pebble Patterned Sheet Flooring with Mastic Bathroom in Living Quarters QCK-038 Exposed Yellow Floor Mastic Water Storage Room in Living Quarters QCK-039 White Sink Undercoating Kitchen in Living Quarters QCK-040 Wall Texture, Drywall and Joint Compound Bedroom 3 QCK-041 Wall Texture, Drywall and Joint Compound Bedroom 2 QCK-042 Wall Texture, Drywall and Joint Compound Water Storage Room QCK-043 Wall Texture, Drywall and Joint Compound Bedroom 3 QCK-044 Wall Texture, Drywall and Joint Compound Living Room QCK-045 Silicon Sealant Exterior Windows QCK-046 White Sealant CMU Exterior QCK-047 Grey Paint and Compound Exterior Concrete Slab QCK-048 2' x 4' Ceiling Panel with Fissure Dots Hallway Connecting to Living Quarters QCK-049 White Texture Perimeter CMU Walls QCK-050 White Texture Perimeter CMU Walls QCK-051 White Texture Perimeter CMU Walls QCK-052 White Texture Perimeter CMU Walls QCK-053 White Texture Perimeter CMU Walls QCK-054 White Texture Perimeter CMU Walls QCK-055 White Texture Perimeter CMU Walls QCK-056 White Sealant Exterior of Living Quarters QCK-057 White Sealant Exterior of Garage QCK-058 Black Sealant Exterior of Equipment Room QCK-059 Cement Insulation Radiator Vent Pipe-Exterior QCK-060 White Texture CMU Block Exterior of Office Addition QCK-061 Black Sealant Base of Radiator Dome Slab QCK-062 Expansion Joint Concrete Slab under Radar Dome QCK-063 Fibrous Black Material Concrete Slab under Radar Dome QCK-064

The following table is a summary of the suspect asbestos-containing materials that have been

Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

QCK-11 Grey Sealant, M Power Box on Exterior of Mezzanine

N.F. I 1 SF Good 1 2% Chrysotile

QCK-20 9" x 9" Green Floor Tile with Clear Mastic, M

Radar Equipment Building

N.F. I 125 SF Fair 2 Tile Layer:

4%

Chrysotile Mastic: ND

QCK-22 12" x 12" White Floor Tile with Black Specks and Black Mastic, M

Office Addition N.F. I 8 SF Fair 2 Tile: 3% Chrysotile Mastic: 2% Chrysotile

QCK-32 12" x 12" White Floor Tile with Black Specks and Black Mastic, M

Old Motor Generator Room

N.F. I 45 SF Good 1 Tile: 3% Chrysotile Mastic: 4% Chrysotile

QCK-33 12" x 12" White Floor Tile with Black Specks and Black Mastic, M

Old Motor Generator Room

N.F. I 45 SF Good 1 Tile: 3% Chrysotile Mastic: 4% Chrysotile

QCK-42 Wall Texture associated with Drywall, S

Bedroom 2 Friable 3,000 SF Good 4 2% Chrysotile

QCK-44 Joint Compound associated with Drywall and Wall Texture, M

Bedroom 3 Friable 3,000 SF Good 4 2% Chrysotile

QCK-45 Joint Compound associated with Drywall and Wall Texture, S

Living Room Friable 3,000 SF Good 4 2% Chrysotile

QCK-56 White Texture associated with Perimeter CMU Walls, M

Interior Office Addition

Friable 10,500

SF

Good 4 5% Chrysotile

QCK-61 White Texture associated with CMU Block, S

Interior Office Addition

Friable 10,500

SF

Good 4 <1% Chrysotile

SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM

QCK Cascade Idaho ARSR ½ with Living quarters, storage and motor generator rooms

6347 Seaview Avenue NW Seattle, WA 98107

SAMPLE LOCATIONS

FAA ARSR

RADAR EQUIPMENT BUILDING

FIGURE 1

DESIGNED BY: DF

DRAWN BY: DC

NOT TO SCALE

DATE: 06/2018 FILE: FIGURE 1 Cascade, Idaho

Suspect Bulk Asbestos Sample Location

LEGEND

(+ ACM) Asbestos-Containing Material (ACM)

PROJECT NO: 204BS01749 Phase 39

(+ ACM)

(+ ACM)

(+ ACM)

(+ ACM)

28 26

21, 55

9" x 9" Green Vinyl Floor Tile

<1% Chrysotile White Wall Texture

12" x 12" White Vinyl Floor Tile and Black Mastic

SAMPLE LOCATIONS

FAA ARSR

RADAR DOME

FIGURE 1

DESIGNED BY: DF

DRAWN BY: DC

NOT TO SCALE

DATE: 06/2018 FILE: FIGURE 1 Cascade, Idaho

Suspect Bulk Asbestos Sample Location

LEGEND

(+ ACM) Asbestos-Containing Material (ACM)

PROJECT NO: 204BS01749 Phase 39

(+ ACM)

09, 10

Grey Sealant on Power Box

SAMPLE LOCATIONS

FAA ARSR

SITE PLOT

FIGURE 1

DESIGNED BY: DF

DRAWN BY: DC

NOT TO SCALE

DATE: 06/2018 FILE: FIGURE 1 Cascade, Idaho

Suspect Bulk Asbestos Sample Location

LEGEND

(+ ACM) Asbestos-Containing Material (ACM)

PROJECT NO: 204BS01749 Phase 39

(+ ACM)

12, 13

(+ ACM)

12" x 12" White Vinyl Floor Tile with Black Mastic

SAMPLE LOCATIONS

FAA ARSR

LIVING QUARTERS

FIGURE 1

DESIGNED BY: DF

DRAWN BY: DC

NOT TO SCALE

DATE: 06/2018 FILE: FIGURE 1 Cascade, Idaho

Suspect Bulk Asbestos Sample Location

LEGEND

(+ ACM) Asbestos-Containing Material (ACM)

PROJECT NO: 204BS01749 Phase 39

(+ ACM)

(+ ACM)

(+ ACM)

38 40

573537

47, 53, 54

White Wall Texture on Drywall

The following table contains a list of 23 sampled accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number 2' x 4' White Ceiling Tile (Fiberglass Backing) Equipment Room (Around Sprinklers/Vents) 01, 02, 03 2' x 4' White Ceiling Tile (Pinhole/Small Fissure) Equipment Room - Drop Ceiling System 04, 05, 06 Plywood Wall Paneling Mud Equipment Room - Office Plywood Paneling

Seams 07, 08, 09

Fiberglass Duct Insulation Exterior HVAC Ducts 10, 11, 12 Duct Seam Mastic (Grey) Equipment Room - Ducts 13, 14, 15 9" x 9" Green Floor Tile/Black Mastic Equipment Room - Strip Under Equipment 16, 17 12" x 12" White Mottle Floor Tile/Mastic Equipment Room - Throughout 18, 19 Tan Cove Base/Mastic Equipment Room - Throughout 20, 21 Black Steal Sealant Exterior - Rador Tower Base 22, 23

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

QDB ARSR

BRECKSVILLE OHIO

Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

16, 17 9" x 9" Green Floor Tile/Black Mastic

Equipment Room - Strip Under Equipment

No 50 SF Good 1 2% Chrysotile

SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM

QDB Brecksville, OH

ARSR ½ building ~2000 sf

The following table contains a list of 29 sampled accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number Exterior dome panel sealant, white Exterior of dome, 3rd floor FAAH-1 Exterior dome panel sealant, white Exterior of dome, 3rd floor FAAH-2 Exterior dome panel sealant, white Exterior of dome, 3rd floor FAAH-3 Interior of dome, black flooring remnant Interior of dome, 3rd floor FAAH-4 Structural stell footing coating, black Feet of dome tower FAAH-5 HVAC sealant, grey Building exterior ductwork FAAH-6 HVAC sealant, dark grey Building exterior ductwork FAAH-7 Remnant white caulk Building exterior FAAH-8 CMU joint sealant Building exterior FAAH-9 Hollow metal door frame caulk Building exterior FAAH-10 Penetration caulk, white Building exterior FAAH-11 Penetration caulk, black Building exterior FAAH-12 HVAC caulk (new), grey Building exterior FAAH-13 Soffit caulk, white Building exerior FAAH-14

QHZ ARSR

HORICON WISCONSON

Window caulk, white Building exterior FAAH-15 Yellow expansion foam Building exterior FAAH-16 2' x 4' white ceiling tile, cloud dot pattern Bathroom, 1st floor FAAH-17 Yellow/tan linoleum, tan/black mastic Bathroom, 1st floor FAAH-18 Tan cove base with tan adhesive Bathroom, 1st floor FAAH-19 Fiberglass insulation with black edge seal West wall control room, 1st floor FAAH-20 12" x 12" cream with tan floor tile, tan/black mastic Throughout, 1st floor FAAH-21 2' x 4' white ceiling tile, random small fissure Control room, 1st floor FAAH-22 Tan cove base with tan adhesive Throughout, 1st floor FAAH-23 HVAC caulk (older), silver Control room, 1st floor FAAH-24 HVAC caulk (new), tan Control room, 1st floor FAAH-25 Sheetrock, taping compound Throughout, 1st floor FAAH-26 Hollow metal door frame caulk Building interior, 1st floor FAAH-27 2' x 4' white ceiling tile, lengthwise fissure Front office, middle area FAAH-28 Epoxy floor finish Generator room, 1st floor FAAH-29

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

TABLE 2: ASBESTOS CONTAINING MATERIALS

Sample Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

FAAH-10 Door frame caulk for hollow metal doors (M)

Interior/Exterior Doors

N.F. I 80 SF Good 1 4% Chrysotile

FAAH-21 Tan/black mastic for 12" cream floor tile (M)

Throughout, 1st floor

N.F. I 2520 SF Good 1 Mastic: 8% Chrysotile

FAAH-26 Drywall/Joint Compound and Tape (M)

Throughout, 1st floor

N.F. II 1,500 SF Good 1 Composite <1%

Chrysotile FAAH-27 Door frame caulk for hollow metal doors (M)

Building interior, 1st floor

N.F. I 80 SF Good 1 5% Chrysotile

SF = square feet, LF= linear feet S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM

QHZ Horicon, WI ARSR ½ building with small storage shed john.bissen Callout

FAAH-1

john.bissen Callout

FAAH-2

john.bissen Callout

FAAH-3

john.bissen Callout

FAAH-4

john.bissen Callout

FAAH-5

The following table contains a list of 15 sampled accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number Expansion Compound Base of FPS Building - Exterior 1 4' x 8' Ceiling Panels 1st Floor - Ceiling East Side 2 Wall Paint - (White) 2nd Floor - Stairwell 3 9" x 9" Floor Tile (Tan) w/ Mastic (Black) 2nd Floor - Server Room - Under Electrical

Cabinets

QJB ARSR

GETTYSBURG S.DAKOTA

12" x 12' Floor Tile (White) w/ Adhesive (Yellow) 2nd Floor - Server Room 5 Cove Base (Tan) w/ Adhesive (Yellow) 2nd Floor - Server Room 6 2' x 4' Ceiling Tile (Random Fissures) 2nd Floor - Office Area 7 Caulking between panels Exterior Stairwell of Dome 8 Sink Undercoating (White) 2nd Floor - Office Sink Area 9 Basecove (Black) w/ Adhesive (Yellow) 3rd Floor - Around HVAC Room 10 Drywall and Joint Compound 3rd Floor - Around HVAC Room 11 Rubber Floor 3rd Floor - HVAC Room Floor 12 Mastic on Walls (Black) 4th Floor - Radome Entrance 13 2' x 4' Ceiling Tile (Random Fissures Pattern) 4th Floor - Office 14 Wall Paint (Brown) 2nd Floor - Stairwell 15

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

TABLE 2: ASBESTOS CONTAINING MATERIALS

Sample Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

1 Expansion Compound (M)

Base of FPS Building - Exterior

N.F. I 250 LF Fair 2 5% Chrysotile

4 9" x 9" Floor Tile (Tan) w/ Mastic (Black) (M)

2nd Floor Server Room Under Equipment

N.F. I 30 SF Fair 2 3% Chrysotile

13 Mastic on Walls (Black) (M)

4th Floor Radome Entrance

N.F. I 750 SF Fair 2 8% Chrysotile

SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM

QJB Gettysburg, SD

FPS located in a 4 story concrete building (MOAT) ~3300 sf per floor.

QJO ARSR

ARLINGTON INDIANA

The following table contains a list of 67 sampled accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number Floor Tile 12" x 12" (cream)/ Mastic (Tan)/ Residual Mastic (Black)

Office/ Equipment Building, Near restroom 001A

Floor Tile 12" x 12" (cream)/ Mastic (Tan) Office/ Equipment Building, SE Building corner 001B Caulk (white) Office/ Equipment Building, Wall panels near restroom 002A

Caulk (white) Office/ Equipment Building, NE building corner near door

002B

Ceiling Tile 2' x 4' (white) Office/ Equipment Building, Restroom 003A Ceiling Tile 2' x 4' (white) Office/ Equipment Building, SW office area 003B Cove Base (black) Office/ Equipment Building, NW corner 004A Cove Base (black) Office/ Equipment Building, NE corner 004B Sink Pad (black) Office/ Equipment Building, Kitchen sink 005A Sink Pad (black) Office/ Equipment Building, Kitchen sink 005B Floor Tile 12" x 12" (tan) old/ Mastic (black) Office/ Equipment Building, Under kitchen cabinets 006A

Floor Tile 12" x 12" (tan) old/ Mastic (black) Office/ Equipment Building, Between equipment and wall, east side

006B

Sealant (yellow) Office/ Equipment Building, HVAC duct near SE building corner

007A

Sealant (yellow) Office/ Equipment Building, HVAC duct near SE building corner

007B

Caulking (white), firmer than sample 002 Office/ Equipment Building, HVAC duct through wall, SE corner

008A

Caulking (white), firmer than sample 002 Office/ Equipment Building, HVAC duct through wall, SE corner

008B

Caulk (red) Office/ Equipment Building, Wall penetration near SE corner

009A

Caulk (red) Office/ Equipment Building, Wall penetration near SE corner

009B

Caulk (white) West Storage, Exterior storage building door 010A Caulk (white) West Storage, Exterior storage building door 010B Caulk (white) Backup Power Building, Various interior locations, generally doors 011A

Caulk (white) Backup Power Building, Various interior locations, generally doors

011B

Floor Tile 12" x 12" (tan)/ Mastic (yellow) Backup Power Building, North end of south room 012A Floor Tile 12" x 12" (tan)/ Mastic (yellow) Backup Power Building, South end of south room 012B Ceiling Tile 2' x 4' Backup Power Building, North end of south room 013A Ceiling Tile 2' x 4' Backup Power Building, South end of south room 013B Cove Base (black)/ Mastic (tan) Backup Power Building, South end of south room 014A Cove Base (black)/ Mastic (tan) Backup Power Building, Northwest corner of north room 014B

Caulk (gray) Backup Power Building, Vent on west side of north room

015A

Caulk (gray) Backup Power Building, Vent on west side of north room

015B

Caulk (red) Backup Power Building, Penetrations on west side of north room

016A

Caulk (red-orange) Backup Power Building, Penetrations on west side of north room

016B

Caulk, putty like (green) Backup Power Building, Penetration between interior areas

017A

Caulk, putty like (green) Backup Power Building, Penetration between interior areas

017B

Drywall/ Joint Compound Backup Power Building, Demising wall between building areas

018A

Drywall/ Joint Compound Backup Power Building, Demising wall between building areas

018B

Caulk (gray) Backup Power Building, Floor slab joints, NE corner N room

019A

Caulk (gray) Backup Power Building, Floor slab joints, NE corner N room

019B

Caulk (white-gray) Backup Power Building, Exterior concrete joints, north of building

020A

Caulk (white-gray) Backup Power Building, Exterior concrete joints, west of building

020B

Caulk (tan) Backup Power Building, Exterior Vent, west side 021A Caulk (tan) Backup Power Building, Exterior Vent, east side 021B Tar (black-gray) Backup Power Building, Exterior foundation east side, north end 022A

Tar (black-gray) Backup Power Building, Exterior foundation east side, south end

022B

Caulk (gray) Backup Power Building, Bottom, exterior NE door 023A Caulk (gray) Backup Power Building, Bottom, exterior NE door 023B Caulk (white) Backup Power Building, Exterior, southeast door 024A Caulk (white) Backup Power Building, Exterior, northwest door 024B Caulk (gray) Backup Power Building, Exterior, west HVAC equipment 025A

Caulk (gray) Backup Power Building, Exterior, west HVAC equipment

025B

Elastomeric coating Office/ Equipment Building, Exterior, HVAC 026A Elastomeric coating Office/ Equipment Building, Exterior, foundation 026B Elastomeric coating Office/ Equipment Building, Exterior, foundation 026C Caulk (cream) Office/ Equipment Building, Exterior joints 027A Caulk (cream) Office/ Equipment Building, Exterior joints 027B Caulk (gray) Office/ Equipment Building, North building seam 028A Caulk (gray) Office/ Equipment Building, North building seam 028B Caulk (gray) West Storage, West overhead door bottom 029A Caulk (gray) West Storage, West overhead door bottom 029B Caulk (gray) Exterior, structure below Radome 030A Caulk (gray) Exterior, structure below Radome 030B Caulk (white) Radome panel joints 031A Caulk (white) Radome panel joints 031B Caulk (gray) Radome stairs 032A Caulk (gray) Radome stairs 032B Caulk (gray) Radome floor 033A Caulk (gray) Radome floor 033B

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

TABLE 2: ASBESTOS CONTAINING MATERIALS

Sample Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

001A Mastic (black) Office/ Equipment Building, Near restroom, likely residual from former flooring

N.F. I Unknown Good 1 2% Chrysotile

006A Floor Tile 12" x 12" (tan) old

Office/ Equipment Building, Under kitchen cabinets

N.F. I 80 SF Good 1 3%

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

006A Floor Tile Mastic (black)

Office/ Equipment Building, Under kitchen cabinets

N.F. I 80 SF Good 1 3% Chrysotile

006B Floor Tile 12" x 12" (tan) old

Office/ Equipment Building, Between equipment and wall, east side

N.F. I 80 SF Good 1 3% Chrysotile

006B Floor Tile Mastic (black)

Office/ Equipment Building, Between equipment and wall, east side

N.F. I 80 SF Good 1 3% Chrysotile

SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM PACM= Presumed asbestos containing materiaL tim.jacobsen Typewriter Note: Asbestos floor tile and mastic is located under equipment, between equipment, and under kitchen cabinets.

QRM ARSR

MAIDEN N.CAROLINA

The following table contains a list of 39 homogeneous areas with a total of 67 bulk samples of accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number Radome Dome Caulk, White (Silicone) Radome Interior (RI) RI-001A Radome Dome Surface RI RI-002A, RI-002B

Pipe Caulk (Silicone) RI RI-003A Door Seal (Silicone) RI RI-004A Radome Dome Material, Fiberglass RI RI-005A Dome Caulk, Clear (Silicone) RI RI-006A Dome Caulk, Yellow (Silicone) RI RI-007A Dome Caulk, White (Silicone) Radome Exterior (RE) RE-001A Caulk (Silicone) RE - Radome Upper Landing (Radar Tower) RE-002A Caulk, Off-White RE - Radome Base (Radar Tower), Behind

Styrofoam

RE-003A,

RE-003B

Dome Surface (Paint and Dome)-Glass Layer RE RE-004A, RE-004B

Dome Surface (Paint and Dome)-Paint RE RE-004A, RE-004B

Particle Board Glue Outer Building: Wood Building (OW) OW-001A

OW-001B

Roor Shingles-Gray OW OW-002A

OW-002B

Roof Shingles-White OW OW-002A

OW-002B

Vinyl Floor Tile (VFT), 12" x 12", Light Brown with Specks

Outer Building: Fiberglass Building (OF) OF-003A, OF-003B

Mastic OF OF-003A, OF-003B

Covebase Mastic OF OF-004A, OF-004B

Wall/Ceiling Material OF OF-005A, OF-005B

Exterior Wall/Roof OF OF-006A, OF-006B

Flat Roof Material Outer Building: Concrete Building (OC) OC-007A, OC-007B

Exterior Window Caulk OF OF-008A, OF-008B

VFT, 12" x 12", White with Brown Flecks ARSR-Office and Equipment Room (A) A-001A, A-001B

Mastic A A-001A, A-001B

Leveler A A-001A, A-001B

VFT, 9" x 9", Dark Green A A-002A, A-002B

Top Mastic A A-002A, A-002B

Bottom Mastic A A-002A, A-002B

Ceiling Tile (CT), 2' x 4', Dotted and Grooved A A-003A, A-003B

CT, 2' x 4', Dotted A A-004A, A-004B

Drywall A A-005A, A-005B

Joint Compound A A-005A, A-005B

Tape A A-005B Covebase Mastic A A-006A, A-006B Paint A A-006A, A-006B Interior Window Caulk, White A A-007A, A-007B Vent Caulk, Light Grey/Tan A A-008A, A-008B Vent Caulk, Dark Grey A A-009A, A-009B Vent Caulk, White A A-010A, A-010B Building Caulk, White/Tan A A-011A, A-011B Door Frame, Caulk, White/Tan A A-012A, A-012B Roof Caulk, Top Edge (Silicone) A A-013A Roof Caulk, Side Edge (Silicone) A A-014A Exterior Door Caulk A A-015A, A015B Exterior Window Caulk (Silicone) A A-016A TSI, 6" Pipe Run on Generator ARSR Bldg Engine Room (ER) ER-001A, ER-001B, ER-001C

Vibration Damper ER ER-002A, ER-002B

Fire Stop, Red ER ER-003A, ER-003B

HVAC Caulk, Grey/Red (Silicone) ER ER-004A

The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:

TABLE 2: ASBESTOS CONTAINING MATERIALS

Sample Number

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

OF-003A,

OF-003B

VFT, 12"x12", Light Brown with Specks (M)

Outer Fiberglass Building (OF)

N.F. I 110 SF Fair 1 2% Chrysotile

A-001A, A-001B

Mastic for 12" x 12", White with Brown Flecks (M)

ARSR Building Non-

ACM

2295 SF Good 1 <1% Chrysotile

A-002A, A-002B

VFT, 9'x9", Dark Green (M)

ARSR Building N.F. I <60 SF Good 1 8% Chrysotile

A-002A, A-002B

Top Mastic (M) ARSR Building N.F. I <60 SF Good 1 2% Chrysotile

A-002A, A-002B

Bottom Mastic (M) ARSR Building N.F. I <60 SF Good 1 5% Chrysotile

A-008A, A-008B

Vent Caulk, Lt Grey/Tan (M)

ARSR Building N.F. I 52 SF Good 1 2% Chrysotile

A-011A, A-011B

Building Caulk, White Tan (M)

ARSR Building N.F. I 40 SF Good 1 2% Chyrsotile

Material Description & Type (T, S, M)

Location Friability Quantity Condition Hazard Rank

Asbestos Content

A-012A, A-012B

Door Frame Caulk, White/Tan (M)

ARSR Building N.F. I 70 SF Good 1 2% Chyrsotile

SF = Square Feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, TSI= Thermal System Insulation CT = Ceiling Tile, VFT = Vinyl Floor Tile Outer Buildings: OW=Wooden Building, OF = Fiberglass Building, OC = Concrete Building Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM PACM= Presumed asbestos containing material Quantities are approximated. The 9X9 VFT in the ARSR was located below existing equipment.

QRM Maiden NC ARSR ½ with small storage building

N

7606 Whitehall Executive Center Drive, Suite 800 Charlotte, North Carolina 28273

(704) 529-3200

Sample Location Map

QRM ARSR

N35 36 38.0 W81 14 18.0 Maiden, North Carolina204BS01749Map based Three Client-provided Site Plans

Bulk Sample IDACM Sample ID

RI-001A

002A 002A

OC

OUTER BUILIDNGS:

OW – Outer Wooden Building OF – Outer Fiberglass Building OC – Outer Concrete Building (Well House)

OF

OW

OFFICE

AREA

EMERGENCY

GENERATOR

ENGINE ROOM

RI-002A

RI-002B

RI-004A

RI-005A

RI-007A

RI-003A

RI-006A

RE-001A

RE-002A

RE-003A RE-003B

RE-004A

RE-004B

EQUIPMENT

ROOM

OW-001B

OW-001A

OW-002A

OW-002B

OF-003A

OF-003B

OF-005A

OF-005B

OF-006B

OF-006A

OC-007A

OC-007B

OC-008A

OC-008B

ER-001A

ER-001B

ER-001C

ER-002A

ER-002B

ER-004A

ER-003A

ER-003B

A-005A A-006A

A-006B

A-002A A-002B

A-003A A-004A

A-003B A-004B

A-005B

A-007A A-007B

A-008A

A-008B

A-009A A-009B

A-010A A-010B

A-011A A-011B

A-012B

A-013A

A-014A

A-015A

A-015B

A-016A

OF-004A

OF-004B

A-001A

A-012A

Samples with <1% asbestos. Not considered to be ACM, but applicable to OSHA.002A

A-001B

Samples collected on 4-17-18

Estimated extent of ACM 9”x9” Dark Green Floor Tile and ACM Brown/Black Mastic *Note, this figure shows the estimated extent of the ACM 9”x9” Dark Green Floor Tile and ACM Brown/Black Floor Tile Mastic below Non-ACM 12”x12’ White with Brown Flecks Vinyl Floor Tile remaining below equipment that reportedly was not removed during abatement activities, and locations of the ACM flooring observed during ATC’s asbestos survey.

The roof system was not sampled, per site contact request because it is a new roof. The roof system is assumed to be ACM unless tested and found to not be ACM.

Estimated extent of ACM Grey/Tan Vent and White Building Caulks

Estimated extent of ACM caulk on door frame

Estimated extent of ACM 12”x12” Brown with Specks Vinyl Flooring in Outer Fiberglass Building (OF)

N

7606 Whitehall Executive Center Drive, Suite 800 Charlotte, North Carolina 28273

(704) 529-3200

Estimated Extent of ACM and Assumed ACM

QRM ARSR

N35 36 38.0 W81 14 18.0

Maiden, North Carolina204BS01749Map based Three Client-provided Site Plans

ACM Sample ID002A

ENGINE ROOM

OF-003A

OF-003B

A-002A A-002B

A-008A

A-008B

A-012B A-012A

Samples collected on 4-17-18

A-011A A-011B

OF

The following table contains a list of 222 sampled accessible building materials suspected of containing asbestos:

TABLE 1: SUSPECT BUILDING MATERIALS

Material Material Sample Location Sample

Number Floor Coating with Concrete, Grey EG Building- Interior F1-A

F1-B F1-C

Wall Insulation- Fiberglass-like EG Building- Interior Walls Throughout W1-A W1-B W1-C

Ceiling Insulation-Fiberglass-like EG Building- Interior Ceiling Throughout C1-A C1-B C1-C

Spray Foam Sealant-Yellow EG Building- Interior Wall and Ceiling Penetrations M1-A M1-B M1-C

QSA ARSR

WEST MESA NEW

MEXICO

Duct Sealant-Beige EG Building-Ductwork- Pinched at Seams M2-A M2-B M2-C

Sealant- Beige EG Building- Base of Exterior Walls M3-A M3-B M3-C

Concrete, Grey Storage Garage- Foundation and Floor Throughout

F1-A F1-B F1-C

Fiberboard with Paint, White Storage Garage- Exterior Walls Throughout M1-A M1-B M1-C

Roofing Shingles, Brown Gravel Cap Storage Garage- Pitched Roof Throughout R1-A R1-B R1-C

Concrete, Grey RACG Building-Foundation Throoughout F1-A F1-B F1-C

Floor Tile and Mastic-12" X 12", Beige and Brown with White Mottling

RACG Building-Floor Throughout F2-A F2-B F2-C

Textured Drywall-Eggshell RACG Building-Interior Walls Throughout W1-A W1-B W1-C

Covebase and Mastic-4" Brown RACG Building- Interior Walls Throughout W2-A W2-B W2-C

Pipe Wrap Insulation, Black, Rubber-like RACG Building- Interior and Exterior Duct Equipment

M1_A M1-B M1-C

CMU and Mortar- 10" X 20", Rigid RACG Building-Exterior, Perimeter Walls M2-A M2-B M2-C

Caulking Compound, Black, Gummy Texture RACG Building-Antenna Cable Junction Boxes M3-A M3-B M3-C

Floor Coating, Grey Storage Shed- Floor Throughout F1-A F1-B F1-C

Textured Drywall, Eggshell Texture Storage Shed- Walls Throguhout W1-A W1-B W1--C

Textured Drywall, Eggshell Texture Storage Shed- Ceiling Throughout C1-A C1-B C1-C

Stucco, Sandy Texture Storage Shed- Exterior Siding Throughout M1-A M1-B M1-C

Duct Sealant, Cream Storage Shed- Exterior Ductwork M2-A M2-B M2-C

Duct Wrap Insulation, White Storage Shed- Exterior Ductwork M3-A M3-B M3-C

Caulking Compound, White, Silicon-like Storage Shed- Cooler Unit in Wall M4-A M4-B M4-C

Paint, Grey Storage Shed- Door M5-A M5-B M5-C

Rolled Roofing Material, Grey Gravel Cap Storage Shed- Small Canopy and Roof Throughout

R1-A R1-B R1-C

Mastic, Beige Roof- Lightening Rods (4) R2-A R2-B R2-C

Concrete, Grey Administration and Garage Building- Interior Throughout, Garage

F1-A F1-B F1-C

Carpet and Mastic, Fibrous, Multi-colored Administration and Garage Building- Lobby, Storage Rooms, Office, Conference Room

F2-A F2-B F2-C

Ceramic Tile and Grout, Beige/Tan Marble-like Design

Administration and Garage Building- Restroom F3-A F3-B F3-C

CMU and Mortar- 10" X 20", Pitted Administration and Garage Building- Garage W1-A W1-B W1-C

Textured Drywall, Orange Peel Texture Administration and Garage Building- Throughout Administration Side of Building

W2-A W2-B W2-C

Cove Base and Mastic-4", Dark Brown Administration and Garage Building- Throughout Administration Side of Building

W3-A W3-B W3-C

Acoustical Ceiling Panel- 2' X 4', Pinholes and Fissures

Administration and Garage Building- Throughout Administration Side of Building

C1-A C1-B C1-C

Duct Wrap Insulation, Foil Covered Fiberglass Administration and Garage Building- Plenum Throughout Administration Side

M1-A M1-B M1-C

Pipe Wrap Insulation-Black, Rubber-like Administration and Garage Building- Lobby Storage, Exterior Duct Equipment

M2-A M2-B M2-C

Sink Acoustical Coating-Black Administration and Garage Building-Conference Room

M3-A M3-B M3-C

CMU and Mortar-10" X 20", Pitted Administration and Garage Building-Exterior Perimeter

M4-A M4-B M4-C

Stucco, Sandy Texture Administration and Garage Building- South Exterior Siding

M5-A M5-B M5-C

Duct Sealant, Tan Administration and Garage Building- North Duct Equipment

M6-A M6-B M6-C

Floor Coating, Black, Sandy Texture (Non-Skid) Radar Dome Building- Radar Dome Floor Throughout

F1-A F1-B F1-C

Floor Tile and Mastic- 12" X 12", Grey with White Mottling

Radar Dome Building- Floor 1 Under Panel Boxes F2-A F2-B F2-C

Floor Tile and Mastic- 12" X 12", Off White/Beige with Mottling

Radar Dome Building- Floor 1 F3-A F3-B F3-C

Floor Tile and Mastic- 20" X 20" sections, Faux Marble Design

Radar Dome Building- Floor 1 Kitchen, Restroom F4-A F4-B F4-C

Carpet and Mastic, Blue Fibrous with Brown Mastic

Radar Dome Building-Floor 2 F5-A F5-B F5-C

Floor Tile and Mastic- 12" X 12", Off White Radar Dome Building- Floor 2 Under Panel Switch Boxes

F6-A F6-B F6-C

Floor Coating, Grey, Sandy Texture (Non-Skid) Radar Dome Building- Exterior Stairwells F7-A F7-B F7-C

Wall Panels, Fiberboard Radar Dome Building-Floor 1, Floor 2, Perimeter Walls (Interior)

W1-A W1-B W1-C

Cove Base and Mastic-4", Light Grey Radar Dome Building- Floor 1, Main Area W2-A W2-B W2-C

Textured Drywall, Light Skip Trowel Texture Radar Dome Building- Floor 1 Doghouse, Floor 2 Doghouse, Kitchen, Restroom, Floor 2 Offices

W3-A W3-B W3-C

Cove Base and Mastic- 4", Brown Radar Dome Building- Floor 1-Kitchen and Restroom

W4-A W4-B W4-C

Cove Base and Mastic-4", Light Blue Radar Dome Building- Floor 2 Throughout W5-A W5-B W5-C

Acoustical Ceiling Panel-2 'X 4', Pinholes and Fissures

Radar Dome Building- Floor 1, Floor 2 Throughout C1-A C1-B C1-C

Acoustical Ceiling Tile- 1' X 1', Pinholes with Brown Adhesive, Brittle

Radar Dome Building- Floor 2 Office and Closet C2-A C2-B C2-C

Paint- Grey Radar Dome Building- Radar Equipment in Dome M1-A M1-B M1-C

Caulking Compound, Blank Radar Dome Building- Radar Dome at Floor Seams

M2-A M2-B M2-C

Fiberglass Panels, Fiberglass-like Radar Dome Building- Radar Dome Panels Throughout

M3-A M3-B M3-C

Caulking Compound, White, Brittle Radar Dome Building- Radar Dome at Base of Dome (Interior)

M4-A M4-B M4-C

Sealant, White, Silicone-like Radar Dome Building-Radar Dome at Panel Seams Throughout

M5-A M5-B M5-C

Sealant, White, Pliable Radar Dome Building- Vents for Radar Dome M6-A M6-B M6-C

Caulking Compound, Off White Radar Dome Building- Base of Radar Dome Catwalk (Exterior)

M7-A M7-B M7-C

Paint, White Radar Dome Building- Radar Dome (Exterior) Throughtout

M8-A M8-B M8-C

Paint, Mint Green Radar Dome Building- Radar Dome Access Hatches

M9-A M9-B M9-C

Caulking Compound, White Radar Dome Building- Floor 1 Kitchen and Restroom

M10-A M10-B M10-C

Sink Acoustical Coating, Black, Rubberlike Radar Dome Building- Floor 1 Kitchen M11-A M11-B M11-C

Paint, White with Black Specks Radar Dome Building- Floors 1 and 2 - Metal Trusses and I-beams; Doghouses

M12-A M12-B M12-C

Duct Wrap Insulation Foil Covered/ Fiberglass Radar Dome Building- Floor 1, Floor 2 Plenums M13-A M13-B M13-C

Spray Foam Sealant- Foam Like Radar Dome Building- Floor 1, Floor 2 (Wall Penetrations, Seams and Patches)

M14-A M14-B M14-C

Duct Sealant, Grey Radar Dome Building- Floor 2 (Ductwork) M15-A M15-B M15-C

Concrete, Grey Radar Dome Building- Stairwells, Foundation, Walkways, Slabs Throughout

M16-A M16-B M16-C

Duct Sealant, Beige Radar Dome Building- Exterior Ductwork M17-A M17-B M17-C

Texture, White, Stucco-like Radar Dome…