1 Suspect Asbestos-Containing Materials
The following table contains a list of 36 sampled accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number 9" x 9" Green Floor Tile Under Green Equipment Main Building L-1A Black Mastic Under Green Equipment Main Building L-1B 9" x 9" Green Floor Tile Under Tan Equipment Main Building L-2A Black Mastic Under Tan Equipment Main Building L-2B 9" x 9" Green Floor Tile Under Tan Equipment Main Building L-3A Black Mastic Under Tan Equipment Main Building L-3B 2' x 4' Ceiling tiles painted white Main Building Bathroom L-4 2' x 4' Ceiling tiles painted white Main Building Bathroom L-5 2' x 4' Ceiling tiles painted white Main Building Bathroom L-6 White window compound Outside Office Window L-7 White compound on cylindrical duct CO Main Building beside BCN & ISM equipment L-8 White 2' x 2' Ceiling tile Main Building-replacement(s) L-9 12" x 12" stone splotched floor tile Main Building L-10A Yellow Mastic Main Building L-10B
QWO ARSR
LONDON OHIO
BUILDING MATERIALS
Material Material Sample Location Sample Number
12" x 12" stone splotched floor tile Main Building L-11A Yellow Mastic Main Building L-11B 12" x 12" stone splotched floor tile Main Building L-12A Yellow Mastic Main Building L-12B 12" x 12" Grey Floor Tile Main Building-Office L-13A Yellow Mastic Main Building-Office L-13B 12" x 12" Grey Floor Tile Main Building-Office L-14A Yellow Mastic Main Building-Office L-14B 12" x 12" Grey Floor Tile Main Building-Office L-15A Yellow Mastic Main Building-Office L-15B 9" x 9" Green Floor Tile Out Building L-16A Black Mastic Out Building L-16B 9" x 9" Green Floor Tile Out Building L-17A Black Mastic Out Building L-17B 9" x 9" Green Floor Tile Out Building L-18A Black Mastic Out Building L-18B Wall Board C-Wall Out Building L-19 Wall Board D-Wall Out Building L-20 Wall Board D-Wall Out Building L-21 Window Glazing Compound Out Building L-22 Bitumen Roofing Main Blding Roof L-23 Bitumen Roofing Main Blding Roof L-24 Bitumen Roofing Main Blding Roof L-25
The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:
TABLE 2: ASBESTOS CONTAINING MATERIALS
Sample Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
L-1A 9" X 9" Green Floor Tile (M)
Under Green Equipment Main Building
No 20 SF Good 1 2% Chrysotile
L-1B Black Mastic (M) Under Green Equipment Main Building
No 20 SF Good 1 3% Chrysotile
L-2A 9" X 9" Green Floor Tile (M)
Under Tan Equipment Main Building
No 12 SF Good 1 2% Chrysotile
L-2B Black Mastic (M) Under Tan Equipment Main Building
No 12 SF Good 1 3% Chrysotile
L-3A 9" X 9" Green Floor Tile (M)
Under Tan Equipment Main Building
No 12 SF Good 1 3% Chrysotile
L-3B Black Mastic (M) Under Tan Equipment Main Building
No 12 SF Good 1 2% Chrysotile
L-8 White compound on cylindrical duct
CO (M)
Main Building beside BCN & ISM equipment
No 1 SF Good 1 2% Chrysotile
L-16A 9" X 9" Green Floor Tile (M)
Out Building No 200 SF Good 1 3% Chrysotile
L-17A 9" X 9" Green Floor Tile (M)
Out Building No 200 SF Good 1 3% Chrysotile
L-18A 9" X 9" Green Floor Tile (M)
Out Building No 200 SF Good 1 3% Chrysotile
SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM PACM= Presumed asbestos containing material
Note 1: The 9" x 9" floor tile is located under existing equipment.
Note 2: The bitumen roofing on the main building was tested and found to contain <1% chrysotile.
BUILDING SCHEMATICS
QWO London, OH
ARSR ½ building additional storage buildings
The following table contains a list of eleven (11) sampled accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number Epoxy Floor Coating, Grey with Black Equipment Room ER-0329-
01A Epoxy Floor Coating, Grey with Black Equipment Room ER-0329-
01B Epoxy Floor Coating, Grey with Black Equipment Room ER-0329-
01C White Fissured Ceiling Panels Equipment Room ER-0329-
02A White Fissured Ceiling Panels Equipment Room ER-0329-
02B
ATL ARSR
MARRIETA GEORGIA
White Fissured Ceiling Panels Equipment Room ER-0329- 02C
Window Glazing, White Exterior of Main Building- SW MB-0329- 03A
Window Glazing, White Exterior of Main Building- NW MB-0329- 03B
Window Glazing, White Exterior of Main Building- NW MB-0329- 03C
Door Caulking, White Exterior of Main Building-Main Entrance MB-0329- 04A
Door Caulking, White Exterior of Main Building-Electrical Room MB-0329- 04B
Door Caulking, White Exterior of Main Building-South Central Entrance MB-0329- 04C
Vent Hood Caulking, Grey Exterior-South Exhaust Vent MB-0329- 05A
Vent Hood Caulking, Grey Exterior-North Central Exhaust Vent MB-0329- 05B
Vent Hood Caulking, Grey Exterior-NW Exhaust Vent MB-0329- 05C
Exhaust Fan Hood Caulking, Grey Exterior-SE Side of Building MB-0329- 06A
Exhaust Fan Hood Caulking, Grey Exterior-SE Side of Building MB-0329- 06B
Exhaust Fan Hood Caulking, Grey Exterior-SE Side of Building MB-0329- 06C
Beige Vinyl Cove Base with Creme Mastic Operators Office MB-0329- 07A
Beige Vinyl Cove Base with Creme Mastic Break Room MB-0329- 07B
Beige Vinyl Cove Base with Creme Mastic Equipment Room MB-0329- 07C
Fire Stop Caulking, Grey NW Office MB-0329- 08A
Fire Stop Caulking, Grey NW Office MB-0329- 08B
Fire Stop Caulking, Grey NW Office MB-0329- 08C
12" x 12" Beige and Black Vinyl Floor Tile with Black Mastic
Main Equipment Room-Inside West Data Storage Cabinet
MB-0329-
09A
12" x 12" Beige & Black Vinyl Floor Tile with Black Mastic
Main Equipment Room-Inside West Data Storage Cabinet
MB-0329-
09B
12" x 12" Tan & Beige Vinyl Floor Tile with Black Mastic
Operators Office MB-0329- 10A
12" x 12" Tan & Beige Vinyl Floor Tile with Yellow Mastic
Break Room MB-0329- 10B
4' x 2' White Fissured Ceiling Panel Main Equipment Room-West MB-0329- 11A
4' x 2' White Fissured Ceiling Panel Main Equipment Room-Central MB-0329- 11B
4' x 2' White Fissured Ceiling Panel Main Equipment Room-East MB-0329- 11C
The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:
TABLE 2: ASBESTOS CONTAINING MATERIALS
Sample Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
MB-0329-
05A
Vent Hood Caulking, Grey (M)
Exterior-North Central Exhaust Vent
N.F. II 32 LF Good 1 4% Chrysotile
MB-0329-
05B
Vent Hood Caulking, Grey (M)
Exterior-North Central Exhaust Vent
N.F. II 32 LF Good 1 4% Chrysotile
MB-0329-
05C
Vent Hood Caulking, Grey (M)
Exterior-NW Exhaust Vent
N.F. II 32 LF Good 1 4% Chrysotile
MB-0329-
06A
Exhaust Fan Hood Caulking, Grey (M)
Exterior-South Side of Building
N.F. II 28 LF Good 1 5% Chrysotile
MB-0329-
06A
Exhaust Fan Hood Caulking, Grey (M)
Exterior-South Side of Building
N.F. II 28 LF Good 1 5% Chrysotile
MB-0329-
06A
Exhaust Fan Hood Caulking, Grey (M)
Exterior-North Side of Building
N.F. II 28 LF Good 1 5% Chrysotile
MB-0329-
09A
Black Mastic associated with 12" x 12" Beige & Black Vinyl Floor Tile (M)
Main Equipment Room-Inside West Data Storage Cabinet
N.F. II 24 SF Good 1 Mastic: 3% Chrysotile
MB-0329-
09A
Black Mastic associated with 12" x 12" Beige & Black Vinyl Floor Tile (M)
Main Equipment Room-Inside West Data Storage Cabinet
N.F. II 24 SF Good 1 Mastic: 3% Chrysotile
SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM PACM= Presumed asbestos containing material
ATL Marietta, GA ARSR ½ building ~2000 sf
Asbestos Sample Location Drawing Red font indicates positive sample location
Blue font indicates negative sample location
The following table contains a list of 16 homogeneous areas with a total of 44 sampled accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number Caulk (white) Interior of dome wall M-1A, M-1B Caulk (grey) Interior of dome flooring joints M-2A, M-2B, M-2C
Caulk (grey) Interior of dome floor edge M-3A, M-3B, M-3C
Caulk (grey) Interior stairway M-4A, M-4B, M-4C
QBE ARSR
BEDFORD VIRGINIA
12"x12" Floor tile and mastic (off white with dashes)
Main building electric room and computer room M-5A, M-5B, M-5C
Cove base mastic (beige) Interior main building M-6A, M-6B
12"x12" Floor tile and mastic (off white with dashes)
Interior main building battery room M-7A, M-7B, M-7C
Cove base mastic (off white) Battery room M-8A, M-8B
2'x4' Ceiling tile (white with holes) Bathroom/offices M-9A, M-9B, M-9C
Drywall and joint compound Generator room M-10A, M-10B, M-10C
Caulk (red fire stop) Battery room M-11A, M-11B, M-11C
Caulk (beige) Exterior M-12A, M-12B, M-12C
Duct work coating Exterior M-13A, M-13B, M-13C
Caulk (white) Exterior filling pipe M-14A, M-14B
Roof tar (black) Exterior roof M-15A, M-15B, M-15C
Caulk (beige) Exterior storage building M-16A, M-16B, M-16C
The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:
TABLE 2: ASBESTOS CONTAINING MATERIALS
Sample Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
M-15A Roof tar, M Roof (patch on roof)
N.F. I 20 SF Fair 1 8% Chrysotile
M-15B Roof tar, M Roof (patch on roof)
N.F. I 20 SF Fair 1 5% chrysotile
SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM
QBE Bedford, VA ARSR 3 with generator and
2725 E. Millbrook Road, Suite 121 Raleigh, NC 27604
(919) 871-0999
SAMPLE LOCATION DRAWING
PROJECT NO: 204BS01749
REVIEWED BY:JC SCALE: NTS DATE: 04-2018
QBE ARSR
N37 31 02.0 W79 30 36.0
BEDFORD, VIRGINIA 24523
M-1A
Main Building
Tower
Storage Building
M-1B
M-2C
M-3C
M-4C
M-2A
M-2B
M-3B
M-3A
M-4B
M-4A
M-7C
M-5A
M-5B
M-5C
M-6A
M-6B
M-7A
M-7B
M-9A
M-8B
M-8A
M-9B
M-9C
M-10A
M-10B
M-10C
M-11A
M-11B
M-11C
M-12A
M-12B M-12C
M-13A M-13B
M-13C
M-14A
M-14B
M-15A
M-15B
M-15C
M-16A
M-16B M-16C
Sample Locations
Positive Sample Locations
2725 E. Millbrook Road, Suite 121 Raleigh, NC 27604
(919) 871-0999
ASBESTOS MATERIAL LOCATION
PROJECT NO: 204BS01749
REVIEWED BY:JC SCALE: NTS DATE: 04-2018
QBE ARSR
N37 31 02.0 W79 30 36.0
BEDFORD, VIRGINIA 24523
Main Building
M-15A
M-15B
= Represents approximate location of asbestos roof tar patch.
3.4 Suspect Asbestos-Containing Materials
The following table contains a list of 71 sampled accessible building materials suspected of containing asbestos:
QBZ ARSR
OSKALOOSA KANSAS
TABLE 1: SUSPECT BUILDING MATERIALS
Number Caulk - White Radome Walls QBZ-CK1
-01 Caulk - White Radome Walls QBZ-CK1
-02 Caulk - White Radome Walls QBZ-CK1
-03 Duct Sealant - Grey Radar Tower QBZ-DS1
-04 Duct Sealant - Grey Radar Tower QBZ-DS1
-05 Caulk - White Radar Tower QBZ-CK2
-06 Caulk - White Radar Tower QBZ-CK2
-07 Caulk - Off-White Radar Tower Base QBZ-CK3
-08 Caulk - Off-White Radar Tower Base QBZ-CK3
-09 Beam Coating - Black Radar Tower Base QBZ-BC1
-10 Beam Coating - Black Radar Tower Base QBZ-BC1
-11 Beam Coating - Black Radar Tower Base QBZ-BC1
-12 Caulk - Grey Exterior HVAC QBZ-CK4
-13 Caulk - Grey Exterior HVAC QBZ-CK4
-14 Roof Flashing Mastic - Black Main Building Roof Penetration QBZ-RF
M1-15 Roof Flashing Mastic - Black Main Building Roof Penetration QBZ-RF
M1-16 Duct Sealant - Grey/Tan Main Building Exterior QBZ-DS2
-17 Duct Sealant - Grey/Tan Main Building Exterior QBZ-DS2
-18 Duct Sealant - Black Main Building Exterior QBZ-DS3
-19 Duct Sealant - Black Main Building Exterior QBZ-DS3
-20 Duct Sealant - Grey Main Building Exterior QBZ-DS4
-21 Duct Sealant - Grey Main Building Exterior QBZ-DS4
-22 Ceiling Tile - 2' x 2' Pinholes & Gouges Equipment Room QBZ-CT1
-23 Ceiling Tile - 2' x 2' Pinholes & Gouges Equipment Room QBZ-CT1
-24 Surfacing Material - Off-White Storage Room 106/Former Generator Room QBZ-SM1
-25 Surfacing Material - Off-White Storage Room 106/Former Generator Room QBZ-SM1
-26 Surfacing Material - Off-White Storage Room 106/Former Generator Room QBZ-SM1
-27 Floor Tile - 12" x 12" Cream w/ Tan Streaks Equipment Room QBZ-FT1-
Floor Tile Mastic - Yellow Equipment Room (u. FT1) QBZ-FT1-
Floor Tile - 12" x 12" Cream w/ Tan Streaks Equipment Room QBZ-FT1-
Floor Tile Mastic - Yellow Equipment Room (u. FT1) QBZ-FT1-
Cove Base - 4" Light Tan Janitor's Closet QBZ-CB1 -30
Cove Base Adhesive - Yellow Janitor's Closet (u. CB1) QBZ-CB1 -30
Cove Base - 4" Light Tan Janitor's Closet QBZ-CB1 -31
Cove Base Adhesive - Yellow Janitor's Closet (u. CB1) QBZ-CB1 -31
Floor Tile - 12" x 12" Cream w/ Blue Streaks Equipment Room under Cabinets QBZ-FT2-
Floor Tile Mastic - Black Equipment Room under Cabinets (u. FT2) QBZ-FT2-
Floor Tile - 12" x 12" Cream w/ Blue Streaks Equipment Room under Cabinets QBZ-FT2-
Floor Tile Mastic - Black Equipment Room under Cabinets (u. FT2) QBZ-FT2-
Caulk - Off-White UPS/Generator Bldg. Base QBZ-CK5 -34
Caulk - Off-White UPS/Generator Bldg. Base QBZ-CK5 -35
Caulk - White Expansion Joint QBZ-CK6 -36
Caulk - White Expansion Joint QBZ-CK6 -37
Floor Tile - 12" x 12" Tan w/ Beige Streaks Break Room QBZ-FT3-
Floor Tile Mastic - Yellow Break Room QBZ-FT3-
Floor Tile - 12" x 12" Tan w/ Beige Streaks Break Room QBZ-FT3-
Floor Tile Mastic - Yellow Break Room QBZ-FT3-
Floor Tile - 12" x 12" Tan w/ Beige Streaks UPS Room QBZ-FT3-
Floor Tile Mastic - Yellow UPS Room QBZ-FT3-
Floor Tile - 12" x 12" Cream w/ Tan Streaks UPS Room QBZ-FT1-
Floor Tile Mastic - Tan UPS Room QBZ-FT1-
Floor Tile - 12" x 12" Cream w/ Red & Blue Streaks
UPS Room QBZ-FT4-
Floor Tile Mastic - Black UPS Room QBZ-FT4-
Floor Tile - 12" x 12" Cream w/ Red & Blue Streaks
UPS Room QBZ-FT4-
Floor Tile Mastic - Black UPS Room QBZ-FT4-
Ceiling Tile - 2' x 4' Textured UPS Room QBZ-CT2 -44
Ceiling Tile - 2' x 4' Textured UPS Room QBZ-CT2 -45
Cove Base - 4" Tan Generator Room QBZ-CB2 -46
Cove Base Adhesive - Yellow Generator Room QBZ-CB2 -46
Cove Base - 4" Tan Generator Room QBZ-CB2 -47
Cove Base Adhesive - Yellow Generator Room QBZ-CB2 -47
Caulk - Grey Main Building Base QBZ-CK7 -48
Caulk - Grey Main Building Base QBZ-CK7 -49
Joint Compound Restroom QBZ-DW 1-50
Drywall Tape Restroom QBZ-DW 1-50
Joint Compound Restroom QBZ-DW 1-50
Drywall Restroom QBZ-DW 1-50
Joint Compound Hallway QBZ-DW 1-51
Drywall Hallway QBZ-DW 1-51
Joint Compound Tech Ops Office QBZ-DW 1-52
Drywall Tech Ops Office QBZ-DW 1-52
The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:
TABLE 2: ASBESTOS CONTAINING MATERIALS
Sample Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
QBZ-BC1
-10,11,12
Beam Coating - Black (M)
Radar Tower Base N.F. II 48 SF Good 1 2% Chrysotile
QBZ-FT2-
32,33
Floor Tile Mastic - Black (u. FT2) (M)
Equipment Room under Cabinets
N.F. I 36 SF Good 1 5-8% Chrysotile
SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM
8246 Marshall Drive Lenexa, Kansas 66214
SITE SKETCH
DESIGNED BY: ATC SCALE: NTS
DRAWN BY: DG DATE: 5/16/18 FILE: SKETCH
REVIEWED BY: TJ
ASBESTOS SURVEY
PROJECT NO: 204BS01749 Air Route Surveillance Radar Shelter (ARSR) Site - QBZ 39.222222, -95.245833
Oskaloosa, Kansas 66054
Legend
03 = Negative Asbestos Sample Locations 05 = Positive or Assumed Asbestos Sample Locations
C
= Asbestos Containing Material Locations
08A
B
D
SITE SKETCH
DESIGNED BY: ATC SCALE: NTS
DRAWN BY: DG DATE: 5/16/18 FILE: SKETCH
REVIEWED BY: TJ
ASBESTOS SURVEY
PROJECT NO: 204BS01749 Air Route Surveillance Radar Shelter (ARSR) Site - QBZ 39.222222, -95.245833
Oskaloosa, Kansas 66054
Legend
46,47
03 = Negative Asbestos Sample Locations 05 = Positive or Assumed Asbestos Sample Locations
A
= Asbestos Containing Material Locations
04,05
06,07
44,45
C
BD
SITE SKETCH
DESIGNED BY: ATC SCALE: NTS
DRAWN BY: DG DATE: 5/16/18 FILE: SKETCH
REVIEWED BY: TJ
ASBESTOS SURVEY
PROJECT NO: 204BS01749 Air Route Surveillance Radar Shelter (ARSR) Site - QBZ 39.222222, -95.245833
Oskaloosa, Kansas 66054
Legend
03 = Negative Asbestos Sample Locations 05 = Positive or Assumed Asbestos Sample Locations
C 30,31
= Asbestos Containing Material Locations
25,26
17,18
21,2219,20
15,16
A
D B
28,29
32,33
38,39
The following table contains a list of 64 sampled accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number White Sealant Radar Dome QCK-01 White Sealant Radar Dome QCK-02 Yellow Insulation and Paper Backing Floor of Radar Dome QCK-03 White Sealant Exterior Base of Dome QCK-04 White Paint Exterior Base of Dome QCK-05 Black Tar Sealant Stairwell to Roof QCK-06 Grey Duct Sealant Exterior Mezzanine QCK-07 White Sealant Exterior Stairwell of Dome QCK-08 Blue Foam with Black Mastic Radar Dome QCK-09 White Sealant Metal Beams inside Dome QCK-010 Grey Sealant Exterior Mezzanine of Dome QCK-011 Black Sealant Roof of Main Building QCK-012 White Sealant Roof of Main Building-beneath Concrete Slabs QCK-013 White Membrane Roof of Main Building QCK-014
QCK ARSR
CASCADE IDAHO
White Sealant 4" Vent Pipe on Roof of Main Building QCK-015 Grey Sealant HVAC Ducting on Roof of Main Building QCK-016 2' x 4' Ceiling Panel with Mesh Layer Office Addition in Main Building QCK-017 12" x 12" White Vinyl Floor Tile with Yellow Mastic Office Addition in Main Building QCK-018 12" x 12" White Vinyl Floor Tile with Yellow Mastic Radar Equipment Room QCK-019 Green 9" x 9" Vinyl Floor Tile with Clear Mastic Radar Equipment Room QCK-020 4" Tan Vinyl Cove Base with Tan Mastic Office Addition in Main Building QCK-021 12" x 12" White Vinyl Floor Tile with Black Streaks and Mastic
Office Addition in Main Building QCK-022
4" Black Vinyl Cove Base with Tan Mastic Office Addition in Main Building QCK-023 Mortar between CMU Blocks Radar Equipment Room QCK-024 Grey Sealant Air Ducting in the Office Addition in Main Building QCK-025 1" x 1" Ceramic Tile Floor with Grey Grout and Mortar and Base Layer
Radar Equipment Room Restroom QCK-026
Exposed Beige Mastic CMU Block in Radar Equipment Room QCK-027 White/Green Paint CMU Block in Radiator Room QCK-028 Grey Coating Plywood Floor in Hallway to Living Quarters QCK-029 Grey Coating Plywood Floor in Hallway to Living Quarters QCK-030 Grey Coating Plywood Floor in Hallway to Living Quarters QCK-031 12" x 12" White Vinyl Floor Tile with Black Streaks and Black Mastic
Old Motor Generator Room QCK-032
12" x 12" White Vinyl Floor Tile with Black Streaks and Black Mastic
Old Motor Generator Room QCK-033
Burgundy Carpet with Leveling Compound/Mastic Old Motor Generator Room QCK-034 4" Pink Vinyl Cove Base with Mastic Office in Living Quarters QCK-035 4" Burgundy Vinyl Cove Base with Cream Mastic Living Room in Living Quarters QCK-036 Pebble Patterned Sheet Flooring with Mastic Kitchen in Living Quarters QCK-037 Pebble Patterned Sheet Flooring with Mastic Bathroom in Living Quarters QCK-038 Exposed Yellow Floor Mastic Water Storage Room in Living Quarters QCK-039 White Sink Undercoating Kitchen in Living Quarters QCK-040 Wall Texture, Drywall and Joint Compound Bedroom 3 QCK-041 Wall Texture, Drywall and Joint Compound Bedroom 2 QCK-042 Wall Texture, Drywall and Joint Compound Water Storage Room QCK-043 Wall Texture, Drywall and Joint Compound Bedroom 3 QCK-044 Wall Texture, Drywall and Joint Compound Living Room QCK-045 Silicon Sealant Exterior Windows QCK-046 White Sealant CMU Exterior QCK-047 Grey Paint and Compound Exterior Concrete Slab QCK-048 2' x 4' Ceiling Panel with Fissure Dots Hallway Connecting to Living Quarters QCK-049 White Texture Perimeter CMU Walls QCK-050 White Texture Perimeter CMU Walls QCK-051 White Texture Perimeter CMU Walls QCK-052 White Texture Perimeter CMU Walls QCK-053 White Texture Perimeter CMU Walls QCK-054 White Texture Perimeter CMU Walls QCK-055 White Texture Perimeter CMU Walls QCK-056 White Sealant Exterior of Living Quarters QCK-057 White Sealant Exterior of Garage QCK-058 Black Sealant Exterior of Equipment Room QCK-059 Cement Insulation Radiator Vent Pipe-Exterior QCK-060 White Texture CMU Block Exterior of Office Addition QCK-061 Black Sealant Base of Radiator Dome Slab QCK-062 Expansion Joint Concrete Slab under Radar Dome QCK-063 Fibrous Black Material Concrete Slab under Radar Dome QCK-064
The following table is a summary of the suspect asbestos-containing materials that have been
Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
QCK-11 Grey Sealant, M Power Box on Exterior of Mezzanine
N.F. I 1 SF Good 1 2% Chrysotile
QCK-20 9" x 9" Green Floor Tile with Clear Mastic, M
Radar Equipment Building
N.F. I 125 SF Fair 2 Tile Layer:
4%
Chrysotile Mastic: ND
QCK-22 12" x 12" White Floor Tile with Black Specks and Black Mastic, M
Office Addition N.F. I 8 SF Fair 2 Tile: 3% Chrysotile Mastic: 2% Chrysotile
QCK-32 12" x 12" White Floor Tile with Black Specks and Black Mastic, M
Old Motor Generator Room
N.F. I 45 SF Good 1 Tile: 3% Chrysotile Mastic: 4% Chrysotile
QCK-33 12" x 12" White Floor Tile with Black Specks and Black Mastic, M
Old Motor Generator Room
N.F. I 45 SF Good 1 Tile: 3% Chrysotile Mastic: 4% Chrysotile
QCK-42 Wall Texture associated with Drywall, S
Bedroom 2 Friable 3,000 SF Good 4 2% Chrysotile
QCK-44 Joint Compound associated with Drywall and Wall Texture, M
Bedroom 3 Friable 3,000 SF Good 4 2% Chrysotile
QCK-45 Joint Compound associated with Drywall and Wall Texture, S
Living Room Friable 3,000 SF Good 4 2% Chrysotile
QCK-56 White Texture associated with Perimeter CMU Walls, M
Interior Office Addition
Friable 10,500
SF
Good 4 5% Chrysotile
QCK-61 White Texture associated with CMU Block, S
Interior Office Addition
Friable 10,500
SF
Good 4 <1% Chrysotile
SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM
QCK Cascade Idaho ARSR ½ with Living quarters, storage and motor generator rooms
6347 Seaview Avenue NW Seattle, WA 98107
SAMPLE LOCATIONS
FAA ARSR
RADAR EQUIPMENT BUILDING
FIGURE 1
DESIGNED BY: DF
DRAWN BY: DC
NOT TO SCALE
DATE: 06/2018 FILE: FIGURE 1 Cascade, Idaho
Suspect Bulk Asbestos Sample Location
LEGEND
(+ ACM) Asbestos-Containing Material (ACM)
PROJECT NO: 204BS01749 Phase 39
(+ ACM)
(+ ACM)
(+ ACM)
(+ ACM)
28 26
21, 55
9" x 9" Green Vinyl Floor Tile
<1% Chrysotile White Wall Texture
12" x 12" White Vinyl Floor Tile and Black Mastic
SAMPLE LOCATIONS
FAA ARSR
RADAR DOME
FIGURE 1
DESIGNED BY: DF
DRAWN BY: DC
NOT TO SCALE
DATE: 06/2018 FILE: FIGURE 1 Cascade, Idaho
Suspect Bulk Asbestos Sample Location
LEGEND
(+ ACM) Asbestos-Containing Material (ACM)
PROJECT NO: 204BS01749 Phase 39
(+ ACM)
09, 10
Grey Sealant on Power Box
SAMPLE LOCATIONS
FAA ARSR
SITE PLOT
FIGURE 1
DESIGNED BY: DF
DRAWN BY: DC
NOT TO SCALE
DATE: 06/2018 FILE: FIGURE 1 Cascade, Idaho
Suspect Bulk Asbestos Sample Location
LEGEND
(+ ACM) Asbestos-Containing Material (ACM)
PROJECT NO: 204BS01749 Phase 39
(+ ACM)
12, 13
(+ ACM)
12" x 12" White Vinyl Floor Tile with Black Mastic
SAMPLE LOCATIONS
FAA ARSR
LIVING QUARTERS
FIGURE 1
DESIGNED BY: DF
DRAWN BY: DC
NOT TO SCALE
DATE: 06/2018 FILE: FIGURE 1 Cascade, Idaho
Suspect Bulk Asbestos Sample Location
LEGEND
(+ ACM) Asbestos-Containing Material (ACM)
PROJECT NO: 204BS01749 Phase 39
(+ ACM)
(+ ACM)
(+ ACM)
38 40
573537
47, 53, 54
White Wall Texture on Drywall
The following table contains a list of 23 sampled accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number 2' x 4' White Ceiling Tile (Fiberglass Backing) Equipment Room (Around Sprinklers/Vents) 01, 02, 03 2' x 4' White Ceiling Tile (Pinhole/Small Fissure) Equipment Room - Drop Ceiling System 04, 05, 06 Plywood Wall Paneling Mud Equipment Room - Office Plywood Paneling
Seams 07, 08, 09
Fiberglass Duct Insulation Exterior HVAC Ducts 10, 11, 12 Duct Seam Mastic (Grey) Equipment Room - Ducts 13, 14, 15 9" x 9" Green Floor Tile/Black Mastic Equipment Room - Strip Under Equipment 16, 17 12" x 12" White Mottle Floor Tile/Mastic Equipment Room - Throughout 18, 19 Tan Cove Base/Mastic Equipment Room - Throughout 20, 21 Black Steal Sealant Exterior - Rador Tower Base 22, 23
The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:
QDB ARSR
BRECKSVILLE OHIO
Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
16, 17 9" x 9" Green Floor Tile/Black Mastic
Equipment Room - Strip Under Equipment
No 50 SF Good 1 2% Chrysotile
SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM
QDB Brecksville, OH
ARSR ½ building ~2000 sf
The following table contains a list of 29 sampled accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number Exterior dome panel sealant, white Exterior of dome, 3rd floor FAAH-1 Exterior dome panel sealant, white Exterior of dome, 3rd floor FAAH-2 Exterior dome panel sealant, white Exterior of dome, 3rd floor FAAH-3 Interior of dome, black flooring remnant Interior of dome, 3rd floor FAAH-4 Structural stell footing coating, black Feet of dome tower FAAH-5 HVAC sealant, grey Building exterior ductwork FAAH-6 HVAC sealant, dark grey Building exterior ductwork FAAH-7 Remnant white caulk Building exterior FAAH-8 CMU joint sealant Building exterior FAAH-9 Hollow metal door frame caulk Building exterior FAAH-10 Penetration caulk, white Building exterior FAAH-11 Penetration caulk, black Building exterior FAAH-12 HVAC caulk (new), grey Building exterior FAAH-13 Soffit caulk, white Building exerior FAAH-14
QHZ ARSR
HORICON WISCONSON
Window caulk, white Building exterior FAAH-15 Yellow expansion foam Building exterior FAAH-16 2' x 4' white ceiling tile, cloud dot pattern Bathroom, 1st floor FAAH-17 Yellow/tan linoleum, tan/black mastic Bathroom, 1st floor FAAH-18 Tan cove base with tan adhesive Bathroom, 1st floor FAAH-19 Fiberglass insulation with black edge seal West wall control room, 1st floor FAAH-20 12" x 12" cream with tan floor tile, tan/black mastic Throughout, 1st floor FAAH-21 2' x 4' white ceiling tile, random small fissure Control room, 1st floor FAAH-22 Tan cove base with tan adhesive Throughout, 1st floor FAAH-23 HVAC caulk (older), silver Control room, 1st floor FAAH-24 HVAC caulk (new), tan Control room, 1st floor FAAH-25 Sheetrock, taping compound Throughout, 1st floor FAAH-26 Hollow metal door frame caulk Building interior, 1st floor FAAH-27 2' x 4' white ceiling tile, lengthwise fissure Front office, middle area FAAH-28 Epoxy floor finish Generator room, 1st floor FAAH-29
The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:
TABLE 2: ASBESTOS CONTAINING MATERIALS
Sample Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
FAAH-10 Door frame caulk for hollow metal doors (M)
Interior/Exterior Doors
N.F. I 80 SF Good 1 4% Chrysotile
FAAH-21 Tan/black mastic for 12" cream floor tile (M)
Throughout, 1st floor
N.F. I 2520 SF Good 1 Mastic: 8% Chrysotile
FAAH-26 Drywall/Joint Compound and Tape (M)
Throughout, 1st floor
N.F. II 1,500 SF Good 1 Composite <1%
Chrysotile FAAH-27 Door frame caulk for hollow metal doors (M)
Building interior, 1st floor
N.F. I 80 SF Good 1 5% Chrysotile
SF = square feet, LF= linear feet S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM
QHZ Horicon, WI ARSR ½ building with small storage shed john.bissen Callout
FAAH-1
john.bissen Callout
FAAH-2
john.bissen Callout
FAAH-3
john.bissen Callout
FAAH-4
john.bissen Callout
FAAH-5
The following table contains a list of 15 sampled accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number Expansion Compound Base of FPS Building - Exterior 1 4' x 8' Ceiling Panels 1st Floor - Ceiling East Side 2 Wall Paint - (White) 2nd Floor - Stairwell 3 9" x 9" Floor Tile (Tan) w/ Mastic (Black) 2nd Floor - Server Room - Under Electrical
Cabinets
QJB ARSR
GETTYSBURG S.DAKOTA
12" x 12' Floor Tile (White) w/ Adhesive (Yellow) 2nd Floor - Server Room 5 Cove Base (Tan) w/ Adhesive (Yellow) 2nd Floor - Server Room 6 2' x 4' Ceiling Tile (Random Fissures) 2nd Floor - Office Area 7 Caulking between panels Exterior Stairwell of Dome 8 Sink Undercoating (White) 2nd Floor - Office Sink Area 9 Basecove (Black) w/ Adhesive (Yellow) 3rd Floor - Around HVAC Room 10 Drywall and Joint Compound 3rd Floor - Around HVAC Room 11 Rubber Floor 3rd Floor - HVAC Room Floor 12 Mastic on Walls (Black) 4th Floor - Radome Entrance 13 2' x 4' Ceiling Tile (Random Fissures Pattern) 4th Floor - Office 14 Wall Paint (Brown) 2nd Floor - Stairwell 15
The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:
TABLE 2: ASBESTOS CONTAINING MATERIALS
Sample Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
1 Expansion Compound (M)
Base of FPS Building - Exterior
N.F. I 250 LF Fair 2 5% Chrysotile
4 9" x 9" Floor Tile (Tan) w/ Mastic (Black) (M)
2nd Floor Server Room Under Equipment
N.F. I 30 SF Fair 2 3% Chrysotile
13 Mastic on Walls (Black) (M)
4th Floor Radome Entrance
N.F. I 750 SF Fair 2 8% Chrysotile
SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM
QJB Gettysburg, SD
FPS located in a 4 story concrete building (MOAT) ~3300 sf per floor.
QJO ARSR
ARLINGTON INDIANA
The following table contains a list of 67 sampled accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number Floor Tile 12" x 12" (cream)/ Mastic (Tan)/ Residual Mastic (Black)
Office/ Equipment Building, Near restroom 001A
Floor Tile 12" x 12" (cream)/ Mastic (Tan) Office/ Equipment Building, SE Building corner 001B Caulk (white) Office/ Equipment Building, Wall panels near restroom 002A
Caulk (white) Office/ Equipment Building, NE building corner near door
002B
Ceiling Tile 2' x 4' (white) Office/ Equipment Building, Restroom 003A Ceiling Tile 2' x 4' (white) Office/ Equipment Building, SW office area 003B Cove Base (black) Office/ Equipment Building, NW corner 004A Cove Base (black) Office/ Equipment Building, NE corner 004B Sink Pad (black) Office/ Equipment Building, Kitchen sink 005A Sink Pad (black) Office/ Equipment Building, Kitchen sink 005B Floor Tile 12" x 12" (tan) old/ Mastic (black) Office/ Equipment Building, Under kitchen cabinets 006A
Floor Tile 12" x 12" (tan) old/ Mastic (black) Office/ Equipment Building, Between equipment and wall, east side
006B
Sealant (yellow) Office/ Equipment Building, HVAC duct near SE building corner
007A
Sealant (yellow) Office/ Equipment Building, HVAC duct near SE building corner
007B
Caulking (white), firmer than sample 002 Office/ Equipment Building, HVAC duct through wall, SE corner
008A
Caulking (white), firmer than sample 002 Office/ Equipment Building, HVAC duct through wall, SE corner
008B
Caulk (red) Office/ Equipment Building, Wall penetration near SE corner
009A
Caulk (red) Office/ Equipment Building, Wall penetration near SE corner
009B
Caulk (white) West Storage, Exterior storage building door 010A Caulk (white) West Storage, Exterior storage building door 010B Caulk (white) Backup Power Building, Various interior locations, generally doors 011A
Caulk (white) Backup Power Building, Various interior locations, generally doors
011B
Floor Tile 12" x 12" (tan)/ Mastic (yellow) Backup Power Building, North end of south room 012A Floor Tile 12" x 12" (tan)/ Mastic (yellow) Backup Power Building, South end of south room 012B Ceiling Tile 2' x 4' Backup Power Building, North end of south room 013A Ceiling Tile 2' x 4' Backup Power Building, South end of south room 013B Cove Base (black)/ Mastic (tan) Backup Power Building, South end of south room 014A Cove Base (black)/ Mastic (tan) Backup Power Building, Northwest corner of north room 014B
Caulk (gray) Backup Power Building, Vent on west side of north room
015A
Caulk (gray) Backup Power Building, Vent on west side of north room
015B
Caulk (red) Backup Power Building, Penetrations on west side of north room
016A
Caulk (red-orange) Backup Power Building, Penetrations on west side of north room
016B
Caulk, putty like (green) Backup Power Building, Penetration between interior areas
017A
Caulk, putty like (green) Backup Power Building, Penetration between interior areas
017B
Drywall/ Joint Compound Backup Power Building, Demising wall between building areas
018A
Drywall/ Joint Compound Backup Power Building, Demising wall between building areas
018B
Caulk (gray) Backup Power Building, Floor slab joints, NE corner N room
019A
Caulk (gray) Backup Power Building, Floor slab joints, NE corner N room
019B
Caulk (white-gray) Backup Power Building, Exterior concrete joints, north of building
020A
Caulk (white-gray) Backup Power Building, Exterior concrete joints, west of building
020B
Caulk (tan) Backup Power Building, Exterior Vent, west side 021A Caulk (tan) Backup Power Building, Exterior Vent, east side 021B Tar (black-gray) Backup Power Building, Exterior foundation east side, north end 022A
Tar (black-gray) Backup Power Building, Exterior foundation east side, south end
022B
Caulk (gray) Backup Power Building, Bottom, exterior NE door 023A Caulk (gray) Backup Power Building, Bottom, exterior NE door 023B Caulk (white) Backup Power Building, Exterior, southeast door 024A Caulk (white) Backup Power Building, Exterior, northwest door 024B Caulk (gray) Backup Power Building, Exterior, west HVAC equipment 025A
Caulk (gray) Backup Power Building, Exterior, west HVAC equipment
025B
Elastomeric coating Office/ Equipment Building, Exterior, HVAC 026A Elastomeric coating Office/ Equipment Building, Exterior, foundation 026B Elastomeric coating Office/ Equipment Building, Exterior, foundation 026C Caulk (cream) Office/ Equipment Building, Exterior joints 027A Caulk (cream) Office/ Equipment Building, Exterior joints 027B Caulk (gray) Office/ Equipment Building, North building seam 028A Caulk (gray) Office/ Equipment Building, North building seam 028B Caulk (gray) West Storage, West overhead door bottom 029A Caulk (gray) West Storage, West overhead door bottom 029B Caulk (gray) Exterior, structure below Radome 030A Caulk (gray) Exterior, structure below Radome 030B Caulk (white) Radome panel joints 031A Caulk (white) Radome panel joints 031B Caulk (gray) Radome stairs 032A Caulk (gray) Radome stairs 032B Caulk (gray) Radome floor 033A Caulk (gray) Radome floor 033B
The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:
TABLE 2: ASBESTOS CONTAINING MATERIALS
Sample Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
001A Mastic (black) Office/ Equipment Building, Near restroom, likely residual from former flooring
N.F. I Unknown Good 1 2% Chrysotile
006A Floor Tile 12" x 12" (tan) old
Office/ Equipment Building, Under kitchen cabinets
N.F. I 80 SF Good 1 3%
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
006A Floor Tile Mastic (black)
Office/ Equipment Building, Under kitchen cabinets
N.F. I 80 SF Good 1 3% Chrysotile
006B Floor Tile 12" x 12" (tan) old
Office/ Equipment Building, Between equipment and wall, east side
N.F. I 80 SF Good 1 3% Chrysotile
006B Floor Tile Mastic (black)
Office/ Equipment Building, Between equipment and wall, east side
N.F. I 80 SF Good 1 3% Chrysotile
SF = square feet, LF= linear feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, T= Thermal System Insulation Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM PACM= Presumed asbestos containing materiaL tim.jacobsen Typewriter Note: Asbestos floor tile and mastic is located under equipment, between equipment, and under kitchen cabinets.
QRM ARSR
MAIDEN N.CAROLINA
The following table contains a list of 39 homogeneous areas with a total of 67 bulk samples of accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number Radome Dome Caulk, White (Silicone) Radome Interior (RI) RI-001A Radome Dome Surface RI RI-002A, RI-002B
Pipe Caulk (Silicone) RI RI-003A Door Seal (Silicone) RI RI-004A Radome Dome Material, Fiberglass RI RI-005A Dome Caulk, Clear (Silicone) RI RI-006A Dome Caulk, Yellow (Silicone) RI RI-007A Dome Caulk, White (Silicone) Radome Exterior (RE) RE-001A Caulk (Silicone) RE - Radome Upper Landing (Radar Tower) RE-002A Caulk, Off-White RE - Radome Base (Radar Tower), Behind
Styrofoam
RE-003A,
RE-003B
Dome Surface (Paint and Dome)-Glass Layer RE RE-004A, RE-004B
Dome Surface (Paint and Dome)-Paint RE RE-004A, RE-004B
Particle Board Glue Outer Building: Wood Building (OW) OW-001A
OW-001B
Roor Shingles-Gray OW OW-002A
OW-002B
Roof Shingles-White OW OW-002A
OW-002B
Vinyl Floor Tile (VFT), 12" x 12", Light Brown with Specks
Outer Building: Fiberglass Building (OF) OF-003A, OF-003B
Mastic OF OF-003A, OF-003B
Covebase Mastic OF OF-004A, OF-004B
Wall/Ceiling Material OF OF-005A, OF-005B
Exterior Wall/Roof OF OF-006A, OF-006B
Flat Roof Material Outer Building: Concrete Building (OC) OC-007A, OC-007B
Exterior Window Caulk OF OF-008A, OF-008B
VFT, 12" x 12", White with Brown Flecks ARSR-Office and Equipment Room (A) A-001A, A-001B
Mastic A A-001A, A-001B
Leveler A A-001A, A-001B
VFT, 9" x 9", Dark Green A A-002A, A-002B
Top Mastic A A-002A, A-002B
Bottom Mastic A A-002A, A-002B
Ceiling Tile (CT), 2' x 4', Dotted and Grooved A A-003A, A-003B
CT, 2' x 4', Dotted A A-004A, A-004B
Drywall A A-005A, A-005B
Joint Compound A A-005A, A-005B
Tape A A-005B Covebase Mastic A A-006A, A-006B Paint A A-006A, A-006B Interior Window Caulk, White A A-007A, A-007B Vent Caulk, Light Grey/Tan A A-008A, A-008B Vent Caulk, Dark Grey A A-009A, A-009B Vent Caulk, White A A-010A, A-010B Building Caulk, White/Tan A A-011A, A-011B Door Frame, Caulk, White/Tan A A-012A, A-012B Roof Caulk, Top Edge (Silicone) A A-013A Roof Caulk, Side Edge (Silicone) A A-014A Exterior Door Caulk A A-015A, A015B Exterior Window Caulk (Silicone) A A-016A TSI, 6" Pipe Run on Generator ARSR Bldg Engine Room (ER) ER-001A, ER-001B, ER-001C
Vibration Damper ER ER-002A, ER-002B
Fire Stop, Red ER ER-003A, ER-003B
HVAC Caulk, Grey/Red (Silicone) ER ER-004A
The following table is a summary of the suspect asbestos-containing materials that have been determined, through laboratory analysis, to contain asbestos:
TABLE 2: ASBESTOS CONTAINING MATERIALS
Sample Number
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
OF-003A,
OF-003B
VFT, 12"x12", Light Brown with Specks (M)
Outer Fiberglass Building (OF)
N.F. I 110 SF Fair 1 2% Chrysotile
A-001A, A-001B
Mastic for 12" x 12", White with Brown Flecks (M)
ARSR Building Non-
ACM
2295 SF Good 1 <1% Chrysotile
A-002A, A-002B
VFT, 9'x9", Dark Green (M)
ARSR Building N.F. I <60 SF Good 1 8% Chrysotile
A-002A, A-002B
Top Mastic (M) ARSR Building N.F. I <60 SF Good 1 2% Chrysotile
A-002A, A-002B
Bottom Mastic (M) ARSR Building N.F. I <60 SF Good 1 5% Chrysotile
A-008A, A-008B
Vent Caulk, Lt Grey/Tan (M)
ARSR Building N.F. I 52 SF Good 1 2% Chrysotile
A-011A, A-011B
Building Caulk, White Tan (M)
ARSR Building N.F. I 40 SF Good 1 2% Chyrsotile
Material Description & Type (T, S, M)
Location Friability Quantity Condition Hazard Rank
Asbestos Content
A-012A, A-012B
Door Frame Caulk, White/Tan (M)
ARSR Building N.F. I 70 SF Good 1 2% Chyrsotile
SF = Square Feet, ND = Non Detected, N/A= Not Applicable S = Surfacing, M= Miscellaneous, TSI= Thermal System Insulation CT = Ceiling Tile, VFT = Vinyl Floor Tile Outer Buildings: OW=Wooden Building, OF = Fiberglass Building, OC = Concrete Building Cat. I= Category I Non-friable ACM, Cat. II= Category II Non-friable ACM PACM= Presumed asbestos containing material Quantities are approximated. The 9X9 VFT in the ARSR was located below existing equipment.
QRM Maiden NC ARSR ½ with small storage building
N
7606 Whitehall Executive Center Drive, Suite 800 Charlotte, North Carolina 28273
(704) 529-3200
Sample Location Map
QRM ARSR
N35 36 38.0 W81 14 18.0 Maiden, North Carolina204BS01749Map based Three Client-provided Site Plans
Bulk Sample IDACM Sample ID
RI-001A
002A 002A
OC
OUTER BUILIDNGS:
OW – Outer Wooden Building OF – Outer Fiberglass Building OC – Outer Concrete Building (Well House)
OF
OW
OFFICE
AREA
EMERGENCY
GENERATOR
ENGINE ROOM
RI-002A
RI-002B
RI-004A
RI-005A
RI-007A
RI-003A
RI-006A
RE-001A
RE-002A
RE-003A RE-003B
RE-004A
RE-004B
EQUIPMENT
ROOM
OW-001B
OW-001A
OW-002A
OW-002B
OF-003A
OF-003B
OF-005A
OF-005B
OF-006B
OF-006A
OC-007A
OC-007B
OC-008A
OC-008B
ER-001A
ER-001B
ER-001C
ER-002A
ER-002B
ER-004A
ER-003A
ER-003B
A-005A A-006A
A-006B
A-002A A-002B
A-003A A-004A
A-003B A-004B
A-005B
A-007A A-007B
A-008A
A-008B
A-009A A-009B
A-010A A-010B
A-011A A-011B
A-012B
A-013A
A-014A
A-015A
A-015B
A-016A
OF-004A
OF-004B
A-001A
A-012A
Samples with <1% asbestos. Not considered to be ACM, but applicable to OSHA.002A
A-001B
Samples collected on 4-17-18
Estimated extent of ACM 9”x9” Dark Green Floor Tile and ACM Brown/Black Mastic *Note, this figure shows the estimated extent of the ACM 9”x9” Dark Green Floor Tile and ACM Brown/Black Floor Tile Mastic below Non-ACM 12”x12’ White with Brown Flecks Vinyl Floor Tile remaining below equipment that reportedly was not removed during abatement activities, and locations of the ACM flooring observed during ATC’s asbestos survey.
The roof system was not sampled, per site contact request because it is a new roof. The roof system is assumed to be ACM unless tested and found to not be ACM.
Estimated extent of ACM Grey/Tan Vent and White Building Caulks
Estimated extent of ACM caulk on door frame
Estimated extent of ACM 12”x12” Brown with Specks Vinyl Flooring in Outer Fiberglass Building (OF)
N
7606 Whitehall Executive Center Drive, Suite 800 Charlotte, North Carolina 28273
(704) 529-3200
Estimated Extent of ACM and Assumed ACM
QRM ARSR
N35 36 38.0 W81 14 18.0
Maiden, North Carolina204BS01749Map based Three Client-provided Site Plans
ACM Sample ID002A
ENGINE ROOM
OF-003A
OF-003B
A-002A A-002B
A-008A
A-008B
A-012B A-012A
Samples collected on 4-17-18
A-011A A-011B
OF
The following table contains a list of 222 sampled accessible building materials suspected of containing asbestos:
TABLE 1: SUSPECT BUILDING MATERIALS
Material Material Sample Location Sample
Number Floor Coating with Concrete, Grey EG Building- Interior F1-A
F1-B F1-C
Wall Insulation- Fiberglass-like EG Building- Interior Walls Throughout W1-A W1-B W1-C
Ceiling Insulation-Fiberglass-like EG Building- Interior Ceiling Throughout C1-A C1-B C1-C
Spray Foam Sealant-Yellow EG Building- Interior Wall and Ceiling Penetrations M1-A M1-B M1-C
QSA ARSR
WEST MESA NEW
MEXICO
Duct Sealant-Beige EG Building-Ductwork- Pinched at Seams M2-A M2-B M2-C
Sealant- Beige EG Building- Base of Exterior Walls M3-A M3-B M3-C
Concrete, Grey Storage Garage- Foundation and Floor Throughout
F1-A F1-B F1-C
Fiberboard with Paint, White Storage Garage- Exterior Walls Throughout M1-A M1-B M1-C
Roofing Shingles, Brown Gravel Cap Storage Garage- Pitched Roof Throughout R1-A R1-B R1-C
Concrete, Grey RACG Building-Foundation Throoughout F1-A F1-B F1-C
Floor Tile and Mastic-12" X 12", Beige and Brown with White Mottling
RACG Building-Floor Throughout F2-A F2-B F2-C
Textured Drywall-Eggshell RACG Building-Interior Walls Throughout W1-A W1-B W1-C
Covebase and Mastic-4" Brown RACG Building- Interior Walls Throughout W2-A W2-B W2-C
Pipe Wrap Insulation, Black, Rubber-like RACG Building- Interior and Exterior Duct Equipment
M1_A M1-B M1-C
CMU and Mortar- 10" X 20", Rigid RACG Building-Exterior, Perimeter Walls M2-A M2-B M2-C
Caulking Compound, Black, Gummy Texture RACG Building-Antenna Cable Junction Boxes M3-A M3-B M3-C
Floor Coating, Grey Storage Shed- Floor Throughout F1-A F1-B F1-C
Textured Drywall, Eggshell Texture Storage Shed- Walls Throguhout W1-A W1-B W1--C
Textured Drywall, Eggshell Texture Storage Shed- Ceiling Throughout C1-A C1-B C1-C
Stucco, Sandy Texture Storage Shed- Exterior Siding Throughout M1-A M1-B M1-C
Duct Sealant, Cream Storage Shed- Exterior Ductwork M2-A M2-B M2-C
Duct Wrap Insulation, White Storage Shed- Exterior Ductwork M3-A M3-B M3-C
Caulking Compound, White, Silicon-like Storage Shed- Cooler Unit in Wall M4-A M4-B M4-C
Paint, Grey Storage Shed- Door M5-A M5-B M5-C
Rolled Roofing Material, Grey Gravel Cap Storage Shed- Small Canopy and Roof Throughout
R1-A R1-B R1-C
Mastic, Beige Roof- Lightening Rods (4) R2-A R2-B R2-C
Concrete, Grey Administration and Garage Building- Interior Throughout, Garage
F1-A F1-B F1-C
Carpet and Mastic, Fibrous, Multi-colored Administration and Garage Building- Lobby, Storage Rooms, Office, Conference Room
F2-A F2-B F2-C
Ceramic Tile and Grout, Beige/Tan Marble-like Design
Administration and Garage Building- Restroom F3-A F3-B F3-C
CMU and Mortar- 10" X 20", Pitted Administration and Garage Building- Garage W1-A W1-B W1-C
Textured Drywall, Orange Peel Texture Administration and Garage Building- Throughout Administration Side of Building
W2-A W2-B W2-C
Cove Base and Mastic-4", Dark Brown Administration and Garage Building- Throughout Administration Side of Building
W3-A W3-B W3-C
Acoustical Ceiling Panel- 2' X 4', Pinholes and Fissures
Administration and Garage Building- Throughout Administration Side of Building
C1-A C1-B C1-C
Duct Wrap Insulation, Foil Covered Fiberglass Administration and Garage Building- Plenum Throughout Administration Side
M1-A M1-B M1-C
Pipe Wrap Insulation-Black, Rubber-like Administration and Garage Building- Lobby Storage, Exterior Duct Equipment
M2-A M2-B M2-C
Sink Acoustical Coating-Black Administration and Garage Building-Conference Room
M3-A M3-B M3-C
CMU and Mortar-10" X 20", Pitted Administration and Garage Building-Exterior Perimeter
M4-A M4-B M4-C
Stucco, Sandy Texture Administration and Garage Building- South Exterior Siding
M5-A M5-B M5-C
Duct Sealant, Tan Administration and Garage Building- North Duct Equipment
M6-A M6-B M6-C
Floor Coating, Black, Sandy Texture (Non-Skid) Radar Dome Building- Radar Dome Floor Throughout
F1-A F1-B F1-C
Floor Tile and Mastic- 12" X 12", Grey with White Mottling
Radar Dome Building- Floor 1 Under Panel Boxes F2-A F2-B F2-C
Floor Tile and Mastic- 12" X 12", Off White/Beige with Mottling
Radar Dome Building- Floor 1 F3-A F3-B F3-C
Floor Tile and Mastic- 20" X 20" sections, Faux Marble Design
Radar Dome Building- Floor 1 Kitchen, Restroom F4-A F4-B F4-C
Carpet and Mastic, Blue Fibrous with Brown Mastic
Radar Dome Building-Floor 2 F5-A F5-B F5-C
Floor Tile and Mastic- 12" X 12", Off White Radar Dome Building- Floor 2 Under Panel Switch Boxes
F6-A F6-B F6-C
Floor Coating, Grey, Sandy Texture (Non-Skid) Radar Dome Building- Exterior Stairwells F7-A F7-B F7-C
Wall Panels, Fiberboard Radar Dome Building-Floor 1, Floor 2, Perimeter Walls (Interior)
W1-A W1-B W1-C
Cove Base and Mastic-4", Light Grey Radar Dome Building- Floor 1, Main Area W2-A W2-B W2-C
Textured Drywall, Light Skip Trowel Texture Radar Dome Building- Floor 1 Doghouse, Floor 2 Doghouse, Kitchen, Restroom, Floor 2 Offices
W3-A W3-B W3-C
Cove Base and Mastic- 4", Brown Radar Dome Building- Floor 1-Kitchen and Restroom
W4-A W4-B W4-C
Cove Base and Mastic-4", Light Blue Radar Dome Building- Floor 2 Throughout W5-A W5-B W5-C
Acoustical Ceiling Panel-2 'X 4', Pinholes and Fissures
Radar Dome Building- Floor 1, Floor 2 Throughout C1-A C1-B C1-C
Acoustical Ceiling Tile- 1' X 1', Pinholes with Brown Adhesive, Brittle
Radar Dome Building- Floor 2 Office and Closet C2-A C2-B C2-C
Paint- Grey Radar Dome Building- Radar Equipment in Dome M1-A M1-B M1-C
Caulking Compound, Blank Radar Dome Building- Radar Dome at Floor Seams
M2-A M2-B M2-C
Fiberglass Panels, Fiberglass-like Radar Dome Building- Radar Dome Panels Throughout
M3-A M3-B M3-C
Caulking Compound, White, Brittle Radar Dome Building- Radar Dome at Base of Dome (Interior)
M4-A M4-B M4-C
Sealant, White, Silicone-like Radar Dome Building-Radar Dome at Panel Seams Throughout
M5-A M5-B M5-C
Sealant, White, Pliable Radar Dome Building- Vents for Radar Dome M6-A M6-B M6-C
Caulking Compound, Off White Radar Dome Building- Base of Radar Dome Catwalk (Exterior)
M7-A M7-B M7-C
Paint, White Radar Dome Building- Radar Dome (Exterior) Throughtout
M8-A M8-B M8-C
Paint, Mint Green Radar Dome Building- Radar Dome Access Hatches
M9-A M9-B M9-C
Caulking Compound, White Radar Dome Building- Floor 1 Kitchen and Restroom
M10-A M10-B M10-C
Sink Acoustical Coating, Black, Rubberlike Radar Dome Building- Floor 1 Kitchen M11-A M11-B M11-C
Paint, White with Black Specks Radar Dome Building- Floors 1 and 2 - Metal Trusses and I-beams; Doghouses
M12-A M12-B M12-C
Duct Wrap Insulation Foil Covered/ Fiberglass Radar Dome Building- Floor 1, Floor 2 Plenums M13-A M13-B M13-C
Spray Foam Sealant- Foam Like Radar Dome Building- Floor 1, Floor 2 (Wall Penetrations, Seams and Patches)
M14-A M14-B M14-C
Duct Sealant, Grey Radar Dome Building- Floor 2 (Ductwork) M15-A M15-B M15-C
Concrete, Grey Radar Dome Building- Stairwells, Foundation, Walkways, Slabs Throughout
M16-A M16-B M16-C
Duct Sealant, Beige Radar Dome Building- Exterior Ductwork M17-A M17-B M17-C
Texture, White, Stucco-like Radar Dome…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.