EDE SIR Attachment J.15 Sample CPDS Type 2 Drawing.pdf

PDF 1 MB Posted

Attached to
Procurement of Electrical Distribution Equipment and Life Cycle Support
Solicitation number
693KA8-18-R-00005
Issued by

About this file

EDE SIR Attachment J.15 Sample CPDS Type 2 Drawing (pdf)

View the file

Other files

File Type Posted
EDE Amend 002 SF30.pdf PDF
EDE SIR Sec A to M Sol_693KA8-18-R-00005.pdf PDF
EDE SIR Attachment J.11 FAA Asset Identification Process and Procedure Guide.pdf PDF
EDE AMEND 002 Attachment J.13 Sample ACEPS Phase II Drawing - MJI.pdf PDF
EDE SIR Attachment J.13 Sample ACEPS Phase II Drawing.pdf PDF
EDE SIR Attachment J.2 Switchboard Specification.pdf PDF
EDE SIR Attachment J.5 DID and CDRL Index.pdf PDF
EDE AMEND 002 SECTION B.xlsx XLSX spreadsheet
EDE SIR Attachment J.9 FAA-STD-028C Contract Training Programs.pdf PDF
Amendment 0001 693KA8-18-R-00005.pdf PDF
EDE SIR Attachment J.12 Cost Build-Up.xlsx XLSX spreadsheet
EDE SIR Attachment J.4 EPMS Specification.pdf PDF
EDE SIR Attachment J-17 Past Performance Questionnaire.doc DOC document
EDE SIR Attachment J.8 FAA-STD-021A Configuration Management.pdf PDF
EDE AMEND 002 QA.xls XLS spreadsheet
EDE SIR Attachment J.15 Sample CPDS Type 2 Drawing.pdf PDF
EDE SIR Attachment J.10 FAA-C-1217G Electrical Work, Interior.pdf PDF
EDE SIR Attachment J.1 Paralleling Switchboard Specification.pdf PDF
EDE SIR Attachment J.3 Interior Distribution System Specification.pdf PDF
EDE SIR Attachment J-18 End-Of-Course Evaluations.pdf PDF
EDE SIR Attachment J.7 FAA-STD-019e Lightning and Surge Protection.pdf PDF
EDE SIR Attachment J-16 Bid Drawing Instructions.pdf PDF
EDE SIR Attachment J.6 DID and CDRL's.pdf PDF
EDE SIR SECTION B.xlsx XLSX spreadsheet
EDE SIR Attachment J.14 Sample CPDS Type 1 Drawing.pdf PDF
EDE SIR Attachment J.9 FAA-STD-028C Contract Training Programs.pdf PDF
EDE SIR Attachment J.5 DID and CDRL Index.pdf PDF
Amendment 0001 693KA8-18-R-00005.pdf PDF
EDE SIR Attachment J-17 Past Performance Questionnaire.doc DOC document
EDE SIR Attachment J.13 Sample ACEPS Phase II Drawing.pdf PDF
EDE SIR Attachment J.2 Switchboard Specification.pdf PDF
EDE SIR Attachment J.4 EPMS Specification.pdf PDF
EDE SIR Attachment J.1 Paralleling Switchboard Specification.pdf PDF
EDE SIR SECTION B.xlsx XLSX spreadsheet
EDE SIR Attachment J.14 Sample CPDS Type 1 Drawing.pdf PDF
EDE SIR Attachment J.11 FAA Asset Identification Process and Procedure Guide.pdf PDF
EDE SIR Attachment J.8 FAA-STD-021A Configuration Management.pdf PDF
EDE SIR Attachment J.3 Interior Distribution System Specification.pdf PDF
EDE SIR Attachment J-18 End-Of-Course Evaluations.pdf PDF
EDE SIR Attachment J.12 Cost Build-Up.xlsx XLSX spreadsheet
EDE SIR Attachment J.10 FAA-C-1217G Electrical Work, Interior.pdf PDF
EDE SIR Attachment J.7 FAA-STD-019e Lightning and Surge Protection.pdf PDF
EDE SIR Attachment J.6 DID and CDRL's.pdf PDF
EDE SIR Attachment J-16 Bid Drawing Instructions.pdf PDF
EDE SIR Sec A to M Sol_693KA8-18-R-00005.pdf PDF
EDE SIR Attachment J.10 FAA-C-1217G Electrical Work, Interior.pdf PDF
EDE SIR Attachment J.2 Switchboard Specification.pdf PDF
EDE SIR Attachment J.3 Interior Distribution System Specification.pdf PDF
EDE SIR Attachment J.9 FAA-STD-028C Contract Training Programs.pdf PDF
EDE SIR Attachment J.8 FAA-STD-021A Configuration Management.pdf PDF
Show 40 more

Latest 50 of 65 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

POWER

PULL BOXES / JUNCTION BOXES

MOTORS

GROUNDING AND LIGHTNING PROTECTION

MISCELLANEOUS

PANELBOARDS AND CABINETS

RACEWAYS

LIGHTING

SIGNAL/TELECOMMUNICATIONS GENERAL NOTES

SINGLE-LINE DIAGRAM

GFM EQUIPMENT

S

GROUND ROD, 10'-0"X3/4" DIA COPPER CLAD STEEL

PB

B

DOOR BELL PUSHBUTTON, MTD 4'-0" AFF

DOOR BELL, MTD 7'-0" AFF

SYMBOL

MOUNTING

+18"

+18"

+48"

AIR TERMINAL (24") (LIGHTNING PROTECTION)

MAIN GROUND PLATE

SUPPLEMENTAL GROUND PLATE

MULTIPOINT GROUND PLATE

MGP

OR

J

G

PC

+60"

+60"

+60"

+18"

HEIGHT, AFF DESCRIPTION SYMBOL DESCRIPTION

SYMBOL

MOUNTING

HEIGHT, AFF DESCRIPTIONSYMBOL

DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

MOUNTING

HEIGHT, AFF

DESCRIPTIONSYMBOL

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

CIRCUIT NUMBERS

HOMERUN CALLOUT INDICATING

(#12 UNLESS INDICATED OTHERWISE)

HOMERUN TO PANEL BOARD

NEUTRAL CONDUCTORS

CONDUCTORS

GROUND PHASE OR SWITCH LEG

T

JUNCTION BOX,

MOTOR

COPPER GROUNDING CONDUCTOR, EXPOSEDG

COMBINATION MOTOR STARTER, NEMA SIZE AS INDICATED

60/3

60/40/3

TRANSFORMER

+60"

P

T

HH

+18"

FAA

FO

BARE COPPER GROUNDING CONDUCTOR UNDERGRADE/IN SLAB

UNFUSED DISCONNECT SWITCH, WHERE 60/3 INDICATES NEMA

FRAME SIZE/NUMBER OF POLES

FUSED DISCONNECT SWITCH, WHERE 60/40/3 INDICATES NEMA

FRAME SIZE/FUSE SIZE/NUMBER OF POLES

3 = 4 = d = k = m =

2P =

OS =

NO TALLIES INDICATE 2 #12 & 1 #12G - 3/4" C, UON

EACH CIRCUIT SHALL HAVE SEPARATE, DEDICATED

NEUTRAL AND GROUND CONDUCTORS.

UNDERGROUND CONDUIT

FAA COMMUNICATION DUCTBANK

POWER DUCTBANK

TELCO DUCTBANK

FIBER OPTIC

CONDUIT TURNING DOWN

CONDUIT TURNING UP

CONDUIT RISER, OR FLOOR SLEEVE

CONDUIT CAPPED

FLEXIBLE CONDUIT

LT = LIQUID TIGHT

CABLE TRAY (NOTED ON DRAWINGS)

ELECTRICAL HANDHOLE

SINGLE GROUNDED HEAVY DUTY RECEPTACLE, 20A, 125V, WALL MOUNTED

QUADRUPLEX GROUNDED HEAVY DUTY RECEPTACLE, 20A, 125V, WALL MOUNTED

DUPLEX GROUNDED HEAVY DUTY RECEPTACLE, 20A, 125V, WALL MOUNTED

DUPLEX GROUNDED HEAVY DUTY RECEPTACLE, 20A, 125V, FLOOR MOUNTED

SPECIAL PURPOSE OUTLET NEMA RATING INDICATED

LUTRON LIGHTING CONTROL SYSTEM BUTTON WALL STATION , UNO

SUBSCRIPT INDICATES

4" SQUARE DUCT WIREWAY

NOTED ON DRAWINGS

DESCRIPTIONSYMBOL

CONDUIT, CONCEALED IN WALLS &

CEILINGS

TRANSFORMER

GROUND

LUTRON WALL STATION -3-WAY

LUTRON WALL STATION -4-WAY

LUTRON WALL STATION DIMMER CONTROL

LUTRON WALL STATION -KEY OPERATED

MANUAL MOTOR STARTER WITH THERMAL OVERLOADS

& PAD LOCKABLE TOGGLE GUARD.

TWO-POLE MANUAL MOTOR STARTER

OCCUPANT SENSOR, FAIL SAFE TYPE WITH DAYLIGHT HARVESTING SENSOR

ELP1-17,19,21

2' LED WRAPAROUND LIGHTING FIXTURE, SURFACE MOUNTED,

TYPE INDICATED

SEE SPECIFICATIONS FOR GFM EQUIPMENT

GROUND ACCESS WELL

2'X4' RECESSED LED LIGHTING FIXTURE. FIXTURE WHICH

HAS 2 OR MORE LAMPS - UPPER CASE LETTER INDICATES TYPE.

LOWER CASE LETTER (a, b, ETC) INDICATES SWITCH CIRCUIT;

NUMBER (1, 2, ETC) INDICATES BRANCH CIRCUIT NUMBER.

4' LED WRAPAROUND LIGHTING FIXTURE, SURFACE MOUNTED,

TYPE INDICATED

4' LED STRIP LIGHTING FIXTURE, TYPE INDICATED

WALL-MOUNTED LIGHTING FIXTURE, TYPE INDICATED

RECESSED LED LIGHTING FIXTURE,

RECESSED LED, WALL WASHER LIGHTING FIXTURE,

PHOTOCELL

EMERGENCY LIGHTING FIXTURE UNIT ON INVERTER BACKUP, TYPE INDICATED

LED POLE MOUNTED LIGHTING FIXTURE, TYPE INDICATED

LED FLOODLIGHT, TYPE INDICATED

LED BOLLARD LIGHT FIXTURE, TYPE INDICATED

OBSTRUCTION LIGHTING FIXTURE, TYPE INDICATED

LPS NOTES

1. THE COMPLETED GROUNDING AND LIGHTNING PROTECTION SYSTEM SHALL MEET THE

"INSTALLATION REQUIREMENTS FOR LIGHTNING PROTECTION SYSTEMS, AND MATERIALS

PER UL96A- MOST CURRENT EDITION". ALL INSTALLATIONS SHALL BE IN COMPLIANCE

WITH FAA STD 19E.

2. THE LIGHTNING PROTECTION SYSTEM COMPONENTS SHALL COMPLY WITH NFPA 780 CLASS-II

SYSTEM INSTALLATION REQUIREMENTS.

3. ALL METALLIC OBJECTS WITHIN 6' OF ROOF COUNTERPOISE OR DOWN CONDUCTORS SHALL BE

BONDED WITH EXOTHERMIC WELD TO ROOF COUNTERPOISE OR DOWN CONDUCTORS.

MAGNETIC MOTOR STARTER, NEMA SIZE AS INDICATED

1. RECEPTACLES SHALL BE COLOR CODED AS PER SPECIFICATIONS, FAA-STD-1217F.

2. ALL COVER PLATES FOR RECEPTACLES, SWITCHES AND TELCO/LAN SHALL

BE BRUSHED STAINLESS STEEL, UON. ALL RECEPTACLE COVERS SHALL BE

3. PROVIDE SEISMIC RESTRAINTS ON ALL CONDUITS. PROVIDE SEISMIC DESIGN

SUBMITTAL FOR APPROVAL PRIOR TO INSTALLATION. SEE SPECIFICATION 26

05 48 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS FOR

ADDITIONAL REQUIREMENTS.

4. RECESSED/PENDANT/SURFACE-MOUNTED LIGHT FIXTURES SHALL HAVE

A MINIMUM OF TWO SEISMIC BRACING WIRE SUPPORTS (12 GAUGE) PER

FIXTURE. FOR PENDANT LIGHT FIXTURES, PROVIDE TRANSVERSE AND

LONGITUDINAL BRACING. FOR RECESSED LIGHT FIXTURES, FASTEN TO

CEILING GRID W/SHEET METAL SCREWS ON ALL FOUR SIDES.

5. MOUNT ALL PANELBOARDS AND CABINETS ON TYPE A/C PLYWOOD. MOUNT

PLYWOOD TO CONCRETE OR MASONRY WALLS USING SELF-DRILLING MASONRY

ANCHORS, 3/8" DIA. X MIN. 3 3/8" EMBEDMENT (HILTI: HSE 2421). SPACE BETWEEN

ANCHORS NOT TO EXCEED 2'-0". PAINT WITH FIRE RETARDANT PAINT, UON. PAINT

SHALL MATCH SURROUNDING WALL PAINT COLORS. FASTENTERS SHALL BE

6. PROVIDE CONNECTIONS TO ALL MOTORS, TO ALL HVAC AND PLUMBING

EQUIPMENT AND TO ALL OTHER EQUIPMENT PROVIDED UNDER OTHER

DIVISIONS OF WORK FROM DISCONNECT SWITCH, STARTER, J-BOX, ETC.

7. MINIMUM TRADE CONDUIT SIZE SHALL BE 3/4". MINIMUM POWER CONDUCTOR SIZE

8. ALL EXTERIOR CONDUIT SHALL BE RIGID GALVANIZED STEEL.

9. ALL CONDUITS SHALL CONTAIN A GREEN GROUND WIRE SIZE IN ACCORDANCE

WITH THE 2014 EDITION OF THE NEC. CONDUIT SHALL NOT BE USED AS A

10. CRITICAL POWER TRANSFORMERS LOCATED IN THE TOWER AND IN TRANSFORMER

ROOMS IN BASE BUILDING SHALL HAVE ELECTROSTATIC

SHIELDING, LOW TEMPERATURE RISE (115 C DEGREE) WITH 115 DEGREE C

INSULATION AND K13 RATED WITH COPPER WINDINGS.

11. ALL HARDWARE, INCLUDING CLAMPS, BOLTS, NUTS, WASHERS, STRUTS, ANCHOR

BOLTS, ANGLES, ETC. USED TO SUPPORT OR INSTALL ANY EXTERIOR (AND

NON-CONDITIONED LOCATIONS) HANDRAIL, EQUIPMENT, PIPE, CONDUIT, BOX

OR OTHER DEVICE SHALL BE STAINLESS STEEL AISI 316.

2-POSITION TELEPHONE OUTLET. MTD 18" AFF UON,

PROVIDE 1-1"C WITH PULL STRING FROM OUTLET TO CABLE TRAY

4-POSITION TELEPHONE/LAN/ OUTLET W/2 VOICE AND 2 DATA,

MTD 18" AFF UON, PROVIDE 2-1"C WITH PULL STRING FROM OUTLET

TO CABLE TRAY

TELEPHONE/LAN/ OUTLET, FLOOR MOUNTED, PROVIDE 2-1"C

WITH PULL STRING FROM FLOOR OUTLET TO NEAREST WALL, UP

WALL TO CABLE TRAY

4'X8'X3/4" TYPE A/C PLYWOOD (WITH GRADE A ON EXPOSED FACE)

BACKBOARD WITH FIRE RETARDANT PAINT, UON. PAINT SHALL

MATCH SURROUNDING WALL PAINT COLORS. FASTENERS SHALL BE

RECESSED AND HOLES FILLS WITH PUTTY. FIRMLY ATTACH TO WALL

+18" DUPLEX GROUNDED HEAVY DUTY RECEPTACLE, GFCI, 20A, 125V, WALL MOUNTED

PANELBOARD, SURFACE

MOUNTED, ESSENTIAL OR CRITICAL

'PH' ON SINGLE LINE DIAGRAM INDICATES

PHASE

+78" (TOP)

SHALL BE #12 THHN. PREWIRED LIGHT WHIPS SMALLER THAN 3/4" ARE ALLOWED.

RECESSED AND HOLES FILLED WITH PUTTY. FIRMLY ANCHOR TO WALL FOR

SEISMIC MOVEMENT.

12. PROVIDE PULLBOX IN ALL CONDUIT RUNS THAT EXCEED FOUR NINETY DEGREE TURNS

FOR POWER AND THREE NINETY DEGREE TURNS FOR TELECOMM SYSTEM. COORDINATE

LOCATION OF PULLBOXES WITH CONDUIT, LIGHTS, DUCTWORK, PIPING, ETC.

13. FOR TOWER CONDUITS-EXPOSED/SURFACE MOUNTED CONDUIT IS ACCEPTABLE IN THE

TOWER WITH THE EXCEPTION OF AREAS WITH SUSPENDED CEILINGS. CONDUIT IN

AREAS OF SUSPENDED CEILINGS SHALL BE RUN ABOVE THE CEILING OR CONCEALED

IN WALLS.

14. PROVIDE GROUNDING BUSHINGS ON ALL FEEDER CIRCUITS (BOTH ENDS AND AT ALL

PULL/JUNCTION BOXES IN BETWEEN).

LABELED SO AS TO IDENTIFY POWER SOURCE (PANEL AND CIRCUIT BREAKER).

2'X2' RECESSED LED LIGHTING FIXTURE, TYPE INDICATED

TYPE INDICATED

TYPE INDICATED

FOR SEISMIC MOVEMENT

TYPICAL FOR ALL LIGHTING FIXTURES

SGP

MPGP

CONTROL MODULE FOR DIMMING SYSTEM

CM1

2'X4' RECESSED LED LIGHTING FIXTURE ON FLS BUS.

FIXTURE WHICH HAS 2 OR MORE LAMPS - UPPER CASE LETTER INDICATES TYPE.

LOWER CASE LETTER (a, b, ETC) INDICATES SWITCH CIRCUIT;

NUMBER (1, 2, ETC) INDICATES BRANCH CIRCUIT NUMBER.

TYPICAL FOR ALL LIGHTING FIXTURES

15. MAINTAIN MINIMUM HEADROOM CLERANCE OF 84".

GROUNDING CONDUCTOR.

16. ALL EXTERIOR RECEPTACLES SHALL BE WEATHER-RESISTANT (WR) WITH

WEATHERPROOF(WP) COVER WHILE ATTACHMENT PLUG IS INSERTED INTO RECEPTACLE.

4' LED STRIP LIGHTING FIXTURE, TYPE INDICATED, ON FLS BUS

17. EACH CIRCUIT SHALL HAVE SEPARATE, DEDICATED NEUTRAL AND GROUND

CONDUCTORS.

2'X2' RECESSED LED LIGHTING FIXTURE ON FLS BUS, TYPE INDICATED

4' LED WRAPAROUND LIGHTING FIXTURE ON INVERTER BACKUP,

SURFACE MOUNTED, TYPE INDICATED

2' LED WRAPAROUND LIGHTING FIXTURE ON FLS BUS,

SURFACE MOUNTED, TYPE INDICATED

OS CEILING MOUNTED OCCUPANCY SENSOR, DUAL TECHNOLOGY TYPE

WITH DAY LIGHT HARVESTING SENSOR

RECESSED LED LIGHTING FIXTURE ON FLS BUS, TYPE INDICATED

WP = WEATHER PROOF SWITCH COVER

EXPOSED CONDUIT

DISTRIBUTION EQUIPMENT NAME LEGEND

BREAKER NAME LEGEND

(EQUIPMENT NAME + FUNCTION)

BREAKER DESIGNATION BY FUNCTION

FB FEEDER BREAKER

GB GENERATOR BREAKER

GM GENERATOR MAIN

GMBB GENERATOR MAINTENANCE BYPASS BREAKER

IB ISOLATION BREAKER

LBB LOAD BANK BREAKER

MB MAIN BREAKER

MBB MAINTENANCE BYPASS BREAKER

MF MAINTENANCE FEEDER

MIB MAINTENANCE ISOLATION BREAKER

MS MAIN SWITCH

NM NORMAL UTILITY POWER MAIN

RIB RECTIFIER INPUT BREAKER

SBB SYSTEM BYPASS BREAKER

TB TIE-BREAKER

KEY INTERLOCK LEGEND

BREAKER ABLE TO BE CLOSED WITH KEY

HELD CAPTIVE

K1

BREAKER LOCKED OPEN AND KEY ABLE

TO BE REMOVED

K1

WR = WATER RESISTANT SWITCH

2-POSITION DATA OUTLET. MTD 18" AFF UON,

PROVIDE 1-1"C WITH PULL STRING FROM OUTLET TO CABLE TRAY

t = TIMER SWITCH

WP = WEATHER PROOF RECEPTACLE COVER

WR = WATER RESISTANT RECEPTACLE

AIR TERMINAL (5'-0")(LIGHTNING PROTECTION)

3t = 3-WAY TIMER SWITCH

4' LED COVE LIGHTING FIXTURE, TYPE INDICATED.

DL CEILING MOUNTED DAYLIGHT HARVESTING SENSOR

P DUAL CHANNEL POWER POLE WITH RECEPTACLES AS NOTED.

2'X4' RECESSED LED LIGHTING FIXTURE ON INVERTER BACKUP.

FIXTURE WHICH HAS 2 OR MORE LAMPS - UPPER CASE LETTER INDICATES TYPE.

LOWER CASE LETTER (a, b, ETC) INDICATES SWITCH CIRCUIT;

NUMBER (1, 2, ETC) INDICATES BRANCH CIRCUIT NUMBER.

TYPICAL FOR ALL LIGHTING FIXTURES

2'X2' RECESSED LED LIGHTING FIXTURE ON INVERTER BACKUP,

TYPE INDICATED

4' LED WRAPAROUND LIGHTING FIXTURE ON FLS BUS,

SURFACE MOUNTED, TYPE INDICATED

2' LED WRAPAROUND LIGHTING FIXTURE ON INVERTER BACKUP,

SURFACE MOUNTED, TYPE INDICATED

4' LED STRIP LIGHTING FIXTURE, TYPE INDICATED, ON INVERTER BACKUP

EXIT SIGN WITH BATTERY BACKUP, SINGLE OR DOUBLE FACE WITH MOUNTING AND

ARROWS AS INDICATED

FIRE PUMP CONTROLLER

W/AUTOMATIC TRANSFER SWITCH

AUTOMATIC TRANSFER SWITCH

WITH ISOLATION BYPASS

DELTA-WYE TRANSFORMER

DESCRIPTIONSYMBOL

MOLDED CASE CIRCUIT BREAKER

DISCONNECT SWITCH

SPD SURGE PROTECIVE DEVICE

BATTERY

ENCLOSED CIRCUIT BREAKER

UNINTERRUPTED POWER SUPPLY

STATIC TRANSFER SWITCH

WITH INTERNAL BYPASS BREAKERS

FEEDER CONTINUATION. REFER TO

KEYED NOTE REFERENCED ON E800

X

(SYSTEM + TYPE + VOLTS + PATH + NUMBER)

SYSTEM DESIGNATION EQUIPMENT TYPE

C CRITICAL POWER H 480 VOLTS

E ESSENTIAL POWER L 208Y/120 VOLTS

G GENERATOR POWER

LB LOAD BANK POWER PATH IDENTIFIER

SE UTILITY SERVICE ENTRANCE

U UPS POWER A PRIMARY BUSS

B ALTERNATE BUSS

EQUIPMENT TYPE M MAINTENANCE

T TEMPORARY

ATS AUTOMATIC TRANSFER SWITCH

D SAFETY SWITCH DISCONNECT NUMBER

DP DISTRIBUTION PANELBOARD (LINE)

GEN GENERATOR 1, 2, ETC.

LB LOAD BANK

P PANELBOARD

S SWITCHBOARD

STS STATIC TRANSFER SWITCH

T TRANSFORMER

UPS UNINTERRUPTIBLE POWER SUPPLY

FEEDER/CONDUIT DESIGNATION.

REFER TO SCHEDULE ON E805

XXX

ST SHUNT TRIP DEVICE

+60" ENCLOSED CIRCUIT BREAKER, NEMA SIZE AS INDICATED

MO MOTOR OPERATOR

18. CONTRACTOR SHALL ALLOCATE SUFFICIENT TIME FOR TESTING AND COMMISSIONING OF

ELECTRICAL SYSTEMS PER SPECIFICATION 26 00 02 SECTION 3.15 IN ORDER TO MEET

THE PROJECT MASTER SCHEDULE .

DOUBLE THROW

DISCONNECT SWITCH

CHECKED

URS project no.

Copyright © 2014 URS Corporation, All Rights Reserved

DESIGNED DATE

H

G

F

E

D

C

B

A

7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

DRAWN

APPROVED BY

JCNISSUED BY

SUBMITTED BY

SIGNATURE:

DATE:

DRAWING NO

SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALE FOR OTHER SIZES

REVIEWED BY

CLT-D-TRACO-

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

TRACON

EASTERN SERVICE AREA ATLANTA, GEORGIA

CHARLOTTE NCCHARLOTTE DOUGLAS INTERNATIONAL AIRPORT (CLT)

PROJECT/SYSTEM ENGINEER ENGINEERING MANAGER

REV APROVED

DATE

REDLINE

DATEDESCRIPTION JCN APVD

400 Northpark Town Center,1000 Abernathy Road, NE.

Suite 900 Tel. No (678)808-8800

Atlanta, Georgia 30328

Fax. (678)808-8400

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

08/31/2015

PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552

FOR OFFICIAL USE ONLY

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

1103700

110370008/31/2015 ISSUED FOR BID

8/

/2

:1 8:

A

M

8/31/2015 10:18:40 AM

15290056

JAW

KCV

E000

KCV

LEGENDS, SYMBOLS, & NOTES

REV

POWER

PULL BOXES / JUNCTION BOXES

MOTORS

GROUNDING AND LIGHTNING PROTECTION

MISCELLANEOUS

PANELBOARDS AND CABINETS

RACEWAYS

SIGNAL/TELECOMMUNICATIONS GENERAL NOTES

SINGLE-LINE DIAGRAM

GFM EQUIPMENT

S

GROUND ROD, 10'-0"X3/4" DIA COPPER CLAD STEEL

PB

B

DOOR BELL PUSHBUTTON, MTD 4'-0" AFF

DOOR BELL, MTD 7'-0" AFF

SYMBOL

MOUNTING

+18"

+18"

+48"

AIR TERMINAL (LIGHTNING PROTECTION)

MAIN GROUND PLATE

SUPPLEMENTAL GROUND PLATE

MULTIPOINT GROUND PLATE

MGP

OR

J

G

RAISED FLOOR PEDESTAL GROUND

+60"

+60"

+60"

+18"

HEIGHT, AFF DESCRIPTION SYMBOL DESCRIPTION

SYMBOL

MOUNTING

HEIGHT, AFF DESCRIPTIONSYMBOL

DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

MOUNTING

HEIGHT, AFF

DESCRIPTIONSYMBOL

SYMBOL DESCRIPTION

CIRCUIT NUMBERS

HOMERUN CALLOUT INDICATING

(#12 UNLESS INDICATED OTHERWISE)

HOMERUN TO PANEL BOARD

NEUTRAL CONDUCTORS

CONDUCTORS

GROUND PHASE OR SWITCH LEG

T

JUNCTION BOX,

MOTOR

COPPER GROUNDING CONDUCTOR, EXPOSEDG

COMBINATION MOTOR STARTER, NEMA SIZE AS INDICATED

60/3

60/40/3

TRANSFORMER

+60"

P

T

HH

+18"

FO

BARE COPPER GROUNDING CONDUCTOR UNDERGRADE/IN SLAB

UNFUSED DISCONNECT SWITCH, WHERE 60/3 INDICATES NEMA

FRAME SIZE/NUMBER OF POLES

FUSED DISCONNECT SWITCH, WHERE 60/40/3 INDICATES NEMA

FRAME SIZE/FUSE SIZE/NUMBER OF POLES

3 = 4 = D = k = m =

2P =

OS =

NO TALLIES INDICATE 2 #12 & 1 #12G - 3/4" C, UON

EACH CIRCUIT SHALL HAVE SEPARATE, DEDICATED

NEUTRAL AND GROUND CONDUCTORS.

UNDERGROUND CONDUIT

FAA COMMUNICATION DUCTBANK

POWER DUCTBANK

TELCO DUCTBANK

FIBER OPTIC

CONDUIT TURNING DOWN

CONDUIT TURNING UP

CONDUIT RISER, OR FLOOR SLEEVE

CONDUIT CAPPED

FLEXIBLE CONDUIT

LT = LIQUID TIGHT

CABLE TRAY (NOTED ON DRAWINGS)

ELECTRICAL HANDHOLE

SINGLE GROUNDED HEAVY DUTY RECEPTACLE, 20A, 125V, WALL MOUNTED

QUADRUPLEX GROUNDED HEAVY DUTY RECEPTACLE, 20A, 125V, WALL MOUNTED

DUPLEX GROUNDED HEAVY DUTY RECEPTACLE, 20A, 125V, WALL MOUNTED

DUPLEX GROUNDED HEAVY DUTY RECEPTACLE, 20A, 125V, FLOOR MOUNTED

SPECIAL PURPOSE OUTLET NEMA RATING INDICATED

LUTRON LIGHTING CONTROL SYSTEM BUTTON WALL STATION, UON

SUBSCRIPT INDICATES

4" OR 6" SQUARE DUCT WIREWAY

NOTED ON DRAWINGS

DESCRIPTIONSYMBOL

CONDUIT, CONCEALED IN WALLS & CEILINGS

TRANSFORMER

MOLDED CASE CIRCUIT

BREAKER

GROUND

3-WAY (LUTRON LIGHTING CONTROL WALL STATION)

4-WAY (LUTRON LIGHTING CONTROL STATION)

DIMMER SWITCH (LUTRON LIGHTING CONTROL WALL STATION)

KEY OPERATED

MANUAL MOTOR STARTER WITH THERMAL OVERLOADS

& PAD LOCKABLE TOGGLE GUARD.

TWO-POLE MANUAL MOTOR STARTER

OCCUPANT SENSOR, FAIL SAFE TYPE

ELP1-17,19,21

SEE SPECIFICATIONS FOR GFM EQUIPMENT

GROUND ACCESS WELL

LPS NOTES

1. THE COMPLETED GROUNDING AND LIGHTNING PROTECTION SYSTEM SHALL MEET THE "INSTALLATION REQUIREMENTS FOR LIGHTNING PROTECTION SYSTEMS, AND MATERIALS PER UL96A- MOST CURRENT

EDITION". ALL INSTALLATIONS SHALL BE IN COMPLIANCE WITH FAA STD 19E.

2. THE LIGHTNING PROTECTION SYSTEM COMPONENTS SHALL COMPLY WITH NFPA 780 CLASS-II SYSTEM

INSTALLATION REQUIREMENTS.

3. ALL METALLIC OBJECTS WITHIN 6' OF ROOF COUNTERPOISE OR DOWN CONDUCTORS SHALL BE BONDED WITH

EXOTHERMIC WELD TO ROOF COUNTERPOISE OR DOWN CONDUCTORS.

MAGNETIC MOTOR STARTER, NEMA SIZE AS INDICATED

1. RECEPTACLES SHALL BE COLOR CODED AS PER SPECIFICATION FAA-STD-1217F.

2. PROVIDE IESNA COMPLIANT LIGHTING FIXTURES IN ALL AREAS.

3. ALL COVER PLATES FOR RECEPTACLES, SWITCHES AND TELCO/LAN SHALL

BE BRUSHED STAINLESS STEEL, UON. ALL RECEPTACLE COVERS SHALL BE

5. RECESSED/PENDANT/SURFACE-MOUNTED LIGHT FIXTURES SHALL HAVE

A MINIMUM OF TWO SEISMIC BRACING WIRE SUPPORTS (12 GAUGE) PER

FIXTURE. FOR PENDANT LIGHT FIXTURES, PROVIDE TRANSVERSE AND

LONGITUDINAL BRACING. FOR RECESSED LIGHT FIXTURES, FASTEN TO

CEILING GRID W/SHEET METAL SCREWS ON ALL FOUR SIDES.

6. MOUNT ALL PANELBOARDS AND CABINETS ON TYPE A-B PLYWOOD. MOUNT PLYWOOD

TO CONCRETE OR MASONRY WALLS USING SELF-DRILLING MASONRY

ANCHORS, 3/8" DIA. X MIN. 3 3/8" EMBEDMENT (HILTI: HSE 2421). SPACE

BETWEEN ANCHORS NOT TO EXCEED 2'-0". PAINT WITH FIRE RETARDANT

PAINT, UON. PAINT SHALL MATCH SURROUNDING WALL PAINT COLORS.

7. PROVIDE CONNECTIONS TO ALL MOTORS, TO ALL HVAC AND PLUMBING

EQUIPMENT AND TO ALL OTHER EQUIPMENT PROVIDED UNDER OTHER

DIVISIONS OF WORK FROM DISCONNECT SWITCH, STARTER, J-BOX, ETC.

8. MINIMUM TRADE CONDUIT SIZE SHALL BE 3/4". MINIMUM POWER CONDUCTOR

9. ALL EXTERIOR CONDUIT SHALL BE RIGID GALVANIZED STEEL.

10. ALL CONDUITS SHALL CONTAIN A GREEN GROUND WIRE SIZE IN ACCORDANCE

WITH THE 2014 EDITION OF THE NEC. CONDUIT SHALL NOT BE USED AS A

11. ALL HARDWARE, INCLUDING CLAMPS, BOLTS, NUTS, WASHERS, STRUTS, ANCHOR

BOLTS, ANGLES, ETC. USED TO SUPPORT OR INSTALL ANY EXTERIOR (AND

NON-CONDITIONED LOCATIONS) HANDRAIL, EQUIPMENT, PIPE, CONDUIT, BOX

OR OTHER DEVICE SHALL BE STAINLESS STEEL AISI 316.

2-POSITION TELEPHONE OUTLET. MTD 18" AFF UON,

PROVIDE 1-1"C FROM OUTLET TO CABLE TRAY

4-POSITION TELEPHONE/LAN/ OUTLET W/2 VOICE AND 2 DATA,

MTD 18" AFF UON, PROVIDE 2-1"C FROM OUTLET TO CABLE TRAY

TELEPHONE/LAN/ OUTLET, FLOOR MOUNTED, PROVIDE 2-1"C

FROM FLOOR OUTLET TO NEAREST WALL, UP WALL TO CABLE TRAY

4'X8'X3/4" TYPE A/B PLYWOOD (WITH GRADE A ON EXPOSED FACE)

BACKBOARD WITH FIRE RETARDANT PAINT, UON. PAINT SHALL

MATCH SURROUNDING WALL PAINT COLORS. FASTENERS SHALL BE

RECESSED AND HOLES FILLS WITH PUTTY. FIRMLY ATTACH TO WALL

+18" DUPLEX GROUNDED HEAVY DUTY RECEPTACLE, GFCI, 20A, 125V, WALL MOUNTED

PANELBOARD, SURFACE

MOUNTED, ESSENTIAL OR CRITICAL

'PH' ON SINGLE LINE DIAGRAM

INDICATES PHASE

+78" (TOP)

FAA

SIZE SHALL BE #12 THHN. PREWIRED LIGHT WHIPS SMALLER THAN 3/4" ARE ALLOWED.

FASTENERS SHALL BE RECESSED AND HOLES FILLED WITH PUTTY. FIRMLY

ANCHOR TO WALL FOR SEISMIC MOVEMENT.

12. PROVIDE PULLBOX IN ALL CIRCUITS THAT EXCEED TWO NINETY DEGREE

TURNS. COORDINATE LOCATION OF PULLBOXES WITH CONDUIT, LIGHTS

DUCTWORK, PIPING, ETC.

13. FOR TOWER CONDUITS-EXPOSED/SURFACE MOUNTED CONDUIT IS

ACCEPTABLE IN THE TOWER WITH THE EXCEPTION OF AREAS WITH SUSPENDED

CEILINGS. CONDUIT IN AREAS OF SUSPENDED CEILINGS SHALL BE RUN ABOVE

THE CEILING OR CONCEALED IN WALLS.

14. PROVIDE GROUNDING BUSHINGS ON ALL FEEDER CIRCUITS (BOTH ENDS AND

AT ALL PULL/JUNCTION BOXES IN BETWEEN).

LABELED SO AS TO IDENTIFY POWER SOURCE (PANEL AND CIRCUIT BREAKER).

FOR SEISMIC MOVEMENT

SGP

MPGP

15. MAINTAIN MINIMUM HEADROOM CLEARANCE OF 84".

GROUNDING CONDUCTOR.

16. ALL EXTERIOR RECEPTACLES SHALL BE WEATHER-RESISTANT (WR) WITH WEATHER PROOF

(WP) COVER WHILE ATTACHMENT PLUG IS INSERTED INTO RECEPTACLE.

17. EACH CIRCUIT SHALL HAVE SEPARATE, DEDICATED NEUTRAL AND GROUND CONDUCTORS.

OS CEILING MOUNTED OCCUPANCY SENSOR, DUAL TECHNOLOGY TYPE

WP = WEATHER PROOF SWITCH COVER/RECEPTACLE COVER

EXPOSED CONDUIT

DISTRIBUTION EQUIPMENT NAME LEGEND

(SYSTEM + TYPE + VOLTS + PATH + NUMBER)

SYSTEM DESIGNATION

C CRITICAL POWER

E ESSENTIAL POWER

G GENERATOR POWER

LB LOAD BANK

SE UTILITY SERVICE ENTRANCE

U UPS POWER

EQUIPMENT TYPE

ATS AUTOMATIC TRANSFER SWITCH

D SAFETY SWITCH DISCONNECT

DP DISTRIBUTION PANELBOARD (I LINE)

GEN GENERATOR

LB LOAD BANK

P BRANCH CIRCUIT PANELBOARD

S SWITCHBOARD

STS STATIC TRANSFER SWITCH

T TRANSFORMER

UPS UNINTERRUPTIBLE POWER SUPPLY

VOLTAGE LEVEL

H 480 VOLTS

L 208Y/120 VOLTS

POWER PATH IDENTIFIER

A PRIMARY BUSS

B ALTERNATE BUSS

M MAINTENANCE

T TEMPORARY

NUMBER

1, 2, ETC.

BREAKER NAME LEGEND

(EQUIPMENT NAME + FUNCTION)

BREAKER DESIGNATION BY FUNCTION

FB FEEDER BREAKER

GB GENERATOR BREAKER

GM GENERATOR MAIN

GMBB GENERATOR MAINTENANCE BYPASS BREAKER

IB ISOLATION BREAKER

LBB LOAD BANK BREAKER

MB MAIN BREAKER

MBB MAINTENANCE BYPASS BREAKER

MF MAINTENANCE FEEDER

MIB MAINTENANCE ISOLATION BREAKER

MS MAIN SWITCH

NM NORMAL UTILITY POWER MAIN

RIB RECTIFIER INPUT BREAKER

SBB SYSTEM BYPASS BREAKER

TB TIE-BREAKER

KEY INTERLOCK LEGEND

BREAKER ABLE TO BE CLOSED WITH KEY

HELD CAPTIVE

K1

BREAKER LOCKED OPEN AND KEY ABLE

TO BE REMOVED

K1

WR = WATER RESISTANT SWITCH/RECEPTACLE

2-POSITION DATA OUTLET. MTD 18" AFF UON,

PROVIDE 1-1"C FROM OUTLET TO CABLE TRAY

t = TIMER SWITCH

4. PROVIDE SEISMIC RESTRAINTS ON ALL CONDUITS. PROVIDE SEISMIC DESIGN

SUBMITTAL FOR APPROVAL PRIOR TO INSTALLATION. SEE SPECIFICATION 26

05 48 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS FOR

ADDITIONAL REQUIREMENTS.

LIGHTING

PC

SYMBOL DESCRIPTION

EXIT SIGN WITH BATTERY BACKUP, SINGLE OR DOUBLE FACE WITH MOUNTING AND

ARROWS AS INDICATED

2' LED WRAPAROUND LIGHTING FIXTURE, SURFACE MOUNTED,

TYPE INDICATED

2'X4' RECESSED LED LIGHTING FIXTURE. FIXTURE WHICH

HAS 2 OR MORE LAMPS - UPPER CASE LETTER INDICATES TYPE.

LOWER CASE LETTER (a, b, ETC) INDICATES SWITCH CIRCUIT;

NUMBER (1, 2, ETC) INDICATES BRANCH CIRCUIT NUMBER.

4' LED WRAPAROUND LIGHTING FIXTURE, SURFACE MOUNTED,

TYPE INDICATED

4' LED STRIP LIGHTING FIXTURE, TYPE INDICATED

WALL-MOUNTED LIGHTING FIXTURE, TYPE INDICATED

RECESSED LED LIGHTING FIXTURE,

RECESSED LED, WALL WASHER LIGHTING FIXTURE,

PHOTOCELL

OBSTRUCTION LIGHTING FIXTURE, TYPE INDICATED

2'X2' RECESSED LED LIGHTING FIXTURE, TYPE INDICATED

TYPE INDICATED

TYPE INDICATED

TYPICAL FOR ALL LIGHTING FIXTURES

CONTROL MODULE FOR DIMMING SYSTEM

CM1

2'X4' RECESSED LED LIGHTING FIXTURE ON FLS BUS.

FIXTURE WHICH HAS 2 OR MORE LAMPS - UPPER CASE LETTER INDICATES TYPE.

LOWER CASE LETTER (a, b, ETC) INDICATES SWITCH CIRCUIT;

NUMBER (1, 2, ETC) INDICATES BRANCH CIRCUIT NUMBER.

TYPICAL FOR ALL LIGHTING FIXTURES

4' LED STRIP LIGHTING FIXTURE, TYPE INDICATED, ON FLS BUS

2'X2' RECESSED LED LIGHTING FIXTURE ON FLS BUS, TYPE INDICATED

4' LED WRAPAROUND LIGHTING FIXTURE ON INVERTER BACKUP,

SURFACE MOUNTED, TYPE INDICATED

2' LED WRAPAROUND LIGHTING FIXTURE ON FLS BUS,

SURFACE MOUNTED, TYPE INDICATED

RECESSED LED LIGHTING FIXTURE ON FLS BUS, TYPE INDICATED

2'X4' RECESSED LED LIGHTING FIXTURE ON INVERTER BACKUP.

FIXTURE WHICH HAS 2 OR MORE LAMPS - UPPER CASE LETTER INDICATES TYPE.

LOWER CASE LETTER (a, b, ETC) INDICATES SWITCH CIRCUIT;

NUMBER (1, 2, ETC) INDICATES BRANCH CIRCUIT NUMBER.

TYPICAL FOR ALL LIGHTING FIXTURES

2'X2' RECESSED LED LIGHTING FIXTURE ON INVERTER BACKUP, TYPE INDICATED

4' LED WRAPAROUND LIGHTING FIXTURE ON FLS BUS,

SURFACE MOUNTED, TYPE INDICATED

2' LED WRAPAROUND LIGHTING FIXTURE ON INVERTER BACKUP,

SURFACE MOUNTED, TYPE INDICATED

4' LED STRIP LIGHTING FIXTURE, TYPE INDICATED, ON INVERTER BACKUP

CENTRAL CONTROL UNIT FOR DIMMING SYSTEM

CCU

18. CONTRACTOR SHALL ALLOCATE SUFFICIENT TIME FOR TESTING AND COMMISSIONING OF

ELECTRICAL SYSTEMS PER SPECIFICATION 26 00 02 SECTION 3.15 IN ORDER TO MEET THE

PROJECT MASTER SCHEDULE .

DOUBLE THROW

DISCONNECT SWITCH

DESCRIPTIONSYMBOL

CHECKED

URS project no.

Copyright © 2013 URS Corporation, All Rights Reserved

DESIGNED DATE

H

G

F

E

D

C

B

A

7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

DRAWN

APPROVED BY

JCNISSUED BY

SUBMITTED BY

SIGNATURE:

DATE:

DRAWING NO

SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALE FOR OTHER SIZES

REVIEWED BY

CLT-D-ATCT-

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

ATCT

EASTERN SERVICE AREA ATLANTA, GEORGIA

CHARLOTTE NCCHARLOTTE DOUGLAS INTERNATIONAL AIRPORT (CLT)

PROJECT/SYSTEM ENGINEER ENGINEERING MANAGER

REV APPROVED

DATE

REDLINE

DATEDESCRIPTION JCN APVD

400 Northpark Town Center,1000 Abernathy Road, NE.

Suite 900 Tel. No (678)808-8800

Atlanta, Georgia 30328

Fax. (678)808-8400

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552

FOR OFFICIAL USE ONLY

08/31/2015 1103700

0 110370008/31/2015 ISSUED FOR BID

8/

/2

2:

:0

PM

8/26/2015 2:10:09 PM

15290056

JAW

KCV

E000

KCV

LEGENDS, SYMBOLS, & NOTES

GENERAL NOTES (FOR SHEETS E801, E802, & E803)

REFER TO SHEETS E500 SERIES FOR PANEL SCHEDULES FOR SIZES AND QUANTITY OF SPARE

BREAKERS AND ADDITIONAL PREPARED SPACES FOR ALL EQUIPMENT.

PROVIDE FINAL ADJUSTMENTS OF RATINGS AND SETTINGS FOR ALL EQUIPMENT PER SHORT

CIRCUIT, ARC FLASH, AND COORDINATION CALCULATIONS. BEFORE ENERGIZING CONTRACTOR

TO FIELD VERIFY CABLE LENGTH AND SUBMIT TO FAA, AND ADJUST FEEDER CONDUCTOR AND

CONDUIT SIZES AS NECESSARY TO ACCOMMODATE FIELD CONDITIONS FOR VOLTAGE DROPS,

AND DERATING FOR BELOW SLAB, ETC. ADJUST FEEDER AND CONDUIT SIZES TO MATCH LUG

SIZE ON PANELBOARDS, SWITCHBOARDS AND SWITCHGEAR. PROVIDE ARC FLASH LABELING

FOR EQUIPMENT. SEE SHORT CIRCUIT COORDINATION STUDY TO BE PERFORMED BY SQUARE

D.

ALL BREAKERS AND SWITCHES SHALL BE IN NORMALLY CLOSED POSITION UNLESS OTHERWISE

NOTED.

FIRE PUMP CONNECTIONS SHALL BE MADE IN ACCORDANCE WITH ALL APPLICABLE CODES

AND AS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.

BREAKERS FOR SERVICES ABOVE 1000A SHALL BE GROUND FAULT PROTECTION (GFP) TYPE

BREAKERS, EXCEPT FOR BREAKERS ON THE FLS BUS, WHICH WILL HAVE GROUND FAULT

INDICATION (GFI).

TRANSFORMER DISCONNECTS SHALL BE LOCATED WITHIN 50 FEET OF TRANSFORMER.

LOCATE SPD AS CLOSE TO THE EQUIPMENT MAIN BREAKER AS POSSIBLE.

FOR CONDUCTOR AND CONDUIT SIZE, SEE DRAWING E805.

ALL SWITCHBOARDS, PANELBOARDS, AND CIRCUIT BREAKERS ARE GFE SQUARE D.

PROVIDE AND AFFIX PERMANENT LABELS TO EACH PIECE EQUIPMENT PER THE REQUIREMENTS

OF 26 05 53 -IDENTIFICATION OF ELECTRICAL SYSTEMS.

ALL CIRCUIT BREAKERS SHALL HAVE PERMANENTLY INSTALLED PADLOCKING ATTACHMENTS.

ALL CONDUITS, CONDUCTORS, AND CONTROL SIGNAL CABLES SHALL BE PROVIDED BY THE

CONTRACTOR.

THE NEUTRAL TERMINAL OF THE SPD SHALL NOT BE LEFT UNCONNECTED. CONNECT NEUTRAL

TERMINAL PER MANUFACTURER'S REQUIREMENTS.

REFER TO E807 AND E807 FOR BREAKER SCHEDULES.

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

KEYED NOTES (FOR SHEETS E801, E802, & E803)

TRIP UNIT POWER FROM LINE SIDE OF BREAKER. VOLTAGE SENSING ON LINE SIDE OF BREAKER. PROVIDE TRIP UNIT WITH

VOLTAGE/CURRENT DISPLAY.

REMOTELY CONTROLLED BREAKER WITH RECLOSER.

SESHA-MB AND SESHB-MB REMOTE CONTROL SWITCH (GFE) - SELECTOR SWITCH, 3-POSITION MOMENTARY-MAINTAINED- MOMENTARY SPRING RETURN TO CENTER, 600V, 10A, 2NO-2NC CONTACTS; CODE B, WITH ONE RED AND ONE GREEN LIGHT.

INSTALLED INSIDE A NEMA 4X S.S. BOX WITH WINDOW. INSTALL OUTSIDE CIRCUIT BREAKER ARC FLASH BOUNDARY.

UNDERGROUND CONDUIT. CONDUIT SHALL BE CAPPED AT EACH END WITH FIRE STOPPING PUTTY AFTER INSTALLATION OF

CONDUCTORS OR PULL STRINGS.

INCOMING MAIN LUGS ONLY.

ATS-FP-CB-A AND ATS-FP-CB-B (GFE) - FIRE PUMP MAIN NORMAL FEED BREAKER IN NEMA 4X S.S. ENCLOSURE WITH WINDOW.

SIZE OVER LOCKED ROTOR. INSTALL REMOTE OPERATOR OUTSIDE OF ARC FLASH BOUNDARY. CONNECT LINE SIDE OF BREAKER DIRECTLY TO THE SECONDARY OF THE UTILITY TRANSFORMER. PROVIDE ADEQUATE LUGS AT THE SECONDARY OF THE UTILITY

TRANSFORMER TO COMPLETE THIS CONNECTION. COORDINATE WORK WITH DUKE ENERGY.

PROVIDE AS 84 CIRCUIT VERTICAL PANELBOARD.

3 POLE, DOUBLE THROW DISCONNECT SWITCH IS CFE.

PROVIDE CONNECTION BETWEEN BUSS A AND BUSS B PAIRED TRANSFORMER GROUND. SEE TRANSFORMER PAIRED

GROUNDING DETAIL 2 ON SHEET E-622.

SPD: RAYVOSS 277-3Y-N1-3-06-C, CLIN 1004 (GFE) MOUNT EXTERNALLY AND AS CLOSE AS POSSIBLE TO MINIMIZE LENGTH

(12") OF CONDUCTORS AND BENDS IN THE CONDUCTORS.

SPD: RAYVOSS 277-3Y-M3-3-06-C, CLIN 1010 (GFE) MOUNT EXTERNALLY AND AS CLOSE AS POSSIBLE TO MINIMIZE LENGTH

(12") OF CONDUCTORS AND BENDS IN THE CONDUCTORS.

SPD: RAYVOSS 120-3Y-M3-4-06-A, CLIN 1003 (GFE) MOUNT EXTERNALLY AND AS CLOSE AS POSSIBLE TO MINIMIZE LENGTH

(12") OF CONDUCTORS AND BENDS IN THE CONDUCTORS.

PROVIDE LOCKABLE CIRCUIT BREAKERS.

PROVIDE SHUNT TRIP CIRCUIT TO E/G CONTROLLER FOR ENGINE GENERATOR LOAD BANK LOAD SHEDDING.

PROVIDE POWER METER. CT'S AND VOLTAGE SENSING SHALL BE PLACED IN A LOCATION TO READ CURRENT AND VOLTAGE FROM THE INCOMING CABLE FROM SESHA. PROVIDE CONTROL POWER FROM DEDICATED 120VAC CRITICAL POWER CIRCUIT.

POSITION CT'S AND VOLTAGE SENSING ON INCOMING LUGS FROM SESHA. METER TO INCLUDE ETHERNET AND DIGITAL INPUT

OPTIONS. LABEL THE DISPLAY "UTILITY FEED" ON EXTERIOR OF THE GEAR.

PROVIDE TEMPORARY ENGINE GENERATOR CONNECTION BOX, 36" X 24" X 12" NEMA 4X S.S. BOX, BERTHOLD ELECTRIC: W16-5S-

M OR APPROVED EQUAL.

PROVIDE 60/60/3, DISCONNECT SWITCH. PROVIDE CONNECTION FROM DISCONNECT SWITCH TO ELEVATOR CONTROLLER.

SEE E/G CONTROLLER INTERCONNECTIONS DETAIL ON DETAIL 1 DRAWING E619 FOR E/G CONTROLLER START SIGNAL, SHUNT TRIPS, REMOTE BREAKER OPERATORS, ATS START SIGNAL, AND ALL OTHER I/O AND CONTROL FUNCTIONS.

SEE SINGLE TRANSFORMER GROUNDING DETAIL 1 ON SHEET E-622.

BOND NEUTRAL TO GROUND WITH 4/0 AWG CONDUCTOR INSIDE ENGINE GENERATOR.

FOR CONTINUATION, SEE SHEET E801.

FOR CONTINUATION, SEE SHEET E802.

FOR CONTINUATION, SEE SHEET E803.

FOR CONTINUATION, SEE SHEET CLT-D-ATCT-E800.

PROVIDE AS 84 CIRCUIT VERTICAL PANELBOARD. FULLY POPULATE EMPTY SPACES WITH SPARE 20A-1P BREAKERS.

PROVIDE KEY TRANSFER BLOCKS.

PROVIDE LOAD SIDE FIRE PUMP MOTOR WIRING PER MANUFACTURER'S RECOMMENDATIONS.

PANEL IS DUAL FED. PROVIDE MB AND MBB AS AUTOMATIC SWITCHES.

SPD: RAYVOSS 277-3Y-M3-4-06-C, CLIN 1011 (GFE) MOUNT EXTERNALLY AND AS CLOSE AS POSSIBLE TO MINIMIZE LENGTH

(12") OF CONDUCTORS AND BENDS IN THE CONDUCTORS.

BOND NEUTRAL TO GROUND INSIDE TEMPORARY GENERATOR CONNECTION BOX. PROVIDE LABEL ON OUTSIDE OF BOX STATING

'DO NOT MAKE NEUTRAL/GROUND BOND AT TEMPORARY GENERATOR'.

ATS-FP-CB-A-PB / ATS-FP-CB-B-PB REMOTE CONTROL SWITCH (GFE) - SELECTOR SWITCH, 3-POSITION MOMENTARY- MAINTAINED-MOMENTARY SPRING RETURN TO CENTER, 600V, 10A, 2NO-2NC CONTACTS; CODE B, WITH ONE RED AND ONE GREEN LIGHT. INSTALLED INSIDE A NEMA 4X S.S. BOX WITH WINDOW. INSTALL OUTSIDE CIRCUIT BREAKER ARC FLASH

BOUNDARY.

PROVIDE ONE EMERGENCY LIGHTING INVERTER SYSTEM WITH (6) 20A-1P OUTPUT DISTRIBUTION BREAKERS AND BATTERY CAPACITY FOR 90 MINUTES OF RUN TIME. CONTROLLED POWER COMPANY #ELU-DJX-5-1S10 OR APROVED EQUAL. CFE.

PROVIDE GROUND FAULT INDICATION AT GENERATOR AND AT REMOTE MONITORS IN THE CAB AND FIRE CONTROL ROOM.

FOR CONTINUATION, SEE SHEET CLT-D-ATCT-E801.

PROVIDE JJ200 THERMAL MAGNETIC BREAKER.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

30.

31.

32.

33.

34.

35.

CHECKED

URS project no.

Copyright © 2014 URS Corporation, All Rights Reserved

DESIGNED DATE

H

G

F

E

D

C

B

A

7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

DRAWN

APPROVED BY

JCNISSUED BY

SUBMITTED BY

SIGNATURE:

DATE:

DRAWING NO

SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALE FOR OTHER SIZES

REVIEWED BY

CLT-D-TRACO-

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

TRACON

EASTERN SERVICE AREA ATLANTA, GEORGIA

CHARLOTTE NCCHARLOTTE DOUGLAS INTERNATIONAL AIRPORT (CLT)

PROJECT/SYSTEM ENGINEER ENGINEERING MANAGER

REV APROVED

DATE

REDLINE

DATEDESCRIPTION JCN APVD

400 Northpark Town Center,1000 Abernathy Road, NE.

Suite 900 Tel. No (678)808-8800

Atlanta, Georgia 30328

Fax. (678)808-8400

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

08/31/2015

PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552

FOR OFFICIAL USE ONLY

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

1103700

110370008/31/2015 ISSUED FOR BID

8/

/2

:2 2:

A

M

8/31/2015 10:22:25 AM

15290056

JAW

KCV

E800

KCV

SINGLE LINE DIAGRAM - TRACON - NOTES

DUKE ENERGY

1000KVA MAIN UTILITY

TRANSFORMER

23.9/13.8KV - 480V,

Z=5.75%, AVAILABLE FAULT

CURRENT=20,918A

GEN-B1

480V, 3PH, 3W

800KW, GFE

(ROOM 187) N G

GEN-B1-

IB

1600AF

1600AT

LSIA, RG

GENERATOR

CONTROLLER

ATS-ELEV-B-

GM-FB LSI

GSHB

1600A, 480V, 3PH,3W

GFE, 18,000 AIR

(ROOM 185)

QED 2

SPD

GFE

NOTE 10

1600AF

1600AT

3P

GEN-B1

GB, LSIA

ATSB-

GM-FB

LSI

ATS-FP-2-

GM-FB

032026

GEN-B1-LB-DS

1200AF

480V, 3P, 3W, NF,

GFE, NEMA 4X S.S.

GEN-B1-LB

750KW,480V,

3P, 3W, GFE

NEMA 4X S.S.

USHB-

GMBB-FB

LSI

100AF

60AT

3P

1600AF

1600AT

3P

250AS

150AT

3P

GSHB-SPD-FB

200AF/200AT

3P

400AF

90AT

3P

SECTION PARTITION

ATS-B,

1600A, 480V, 3P, 3W

GFE, 25,000 WCR

(ROOM 185)

UPS-B

100KVA, 480V

3P, 3W

GFE (ROOM 184)

UPS-B-BATT-CB

400AF/400AT

ATS-B-

FB LSI

SEDSHB

1600A, 480V, 3PH,3W

GFE, 25,000 AIR

(ROOM 185)

QED 2

SPD

GFE

NOTE 10

SEDSHB-SPD-FB

200AF/200AT

3P

ATS-ELEV-

B-FB LSI

100AF

60AT

3P

1600AF

1600AT

3P

SECTION

PARTITION

NOTE 4

NOTE 5

EPMS SECTION

NOTE 15

T-EDPLB

150KVA

480V- 208Y/120V, GFE

(ROOM 185)

M

NOTE 18

NOTE 20

ATS-FP-CB-A

480V, 3P, 3W

600AF/500AT

GFE, NOTE 2,6

NEMA 4X S.S.

GEN-A1

480V, 3PH, 3W

800KW, GFE

(ROOM 182) N G

GEN-A1-

IB

1600AF

1600AT

LSIA, RG

SESHA-MB-PB

REMOTE CONTROL

SWITCH NOTE 3

GENERATOR

CONTROLLER

FP-1 FIRE PUMP

CONTROLLER

WITH ATS

50HP

NOTE 27

ATS-ELEV-A-

GM-FB LSI

GSHA

1600A, 480V, 3PH,3W

GFE, 18,000 AIR

(ROOM 179)

QED 2

018 019

ATS-FLS-

GM-FB LSI

SPD

GFE

NOTE 10

1600AF

1600AT

3P G1

GEN-A1-

GB, LSIA

ATSA-

GM-FB

LSI

ATS-FP-1-

GM-FB

020015

GEN-A1-LB-DS

1200AF, 480V,

3P, 3W, NF, GFE

NEMA 4X S.S.

GEN-A1-LB

750KW,480V, 3P, 3W

GFE, NEMA 4X S.S.

USHA-

GMBB-FB

LSI

100AF

60AT

3P

400AS

125AT

3P

1600AF

1600AT

3P

250AS

150AT

3P

GSHA-SPD-FB

200AF/200AT

3P

400AF

100AT

3P

SECTION PARTITION

ATS-A,

1600A, 480V, 3P, 3W

GFE, 25,000 WCR

(ROOM 179)

UPS-A

100KVA, 480V

3PH, 3W

GFE (ROOM 180)

UPS-A-BATT-CB

400AF/400AT

023 ELEV-DS-A

480V, 3P, 3W

60AF/60A

CFE (ROOM 173)

NOTE 17024

ELEVATOR A

CONTROLLER

ATS-ELEV-A,

150A,3P,3W

480V, GFE

18,000 WCR

(ROOM 173)

ATS-A-

FB LSI

SEDSHA

1600A, 480V

3PH, 3W

GFE

25,000 AIR

(ROOM 179)

QED 2

SPD

GFE

NOTE 10

SEDSHA-SPD-FB

200AF/200AT

3P

008009006

ATS-FLS-

FB LSI

ATS-ELEV-

A-FB LSI

100AF

60AT

3P

1600AF

1600AT

3P

400AS

125AT

3P

SECTION

PARTITION

NOTE 4

NOTE 5

EPMS

SECTION

NOTE 15

T-EDPLA

150KVA

480V-208Y/120V, GFE(ROOM 179)

1600AF

1600AT

3P G1

GEN-T-GB

N.O., LSIA

NOTE 18

NOTE 9

NOTE 20

DUKE ENERGY

1000KVA MAIN UTILITY

TRANSFORMER

23.9/13.8KV - 480V,

Z=5.75%, AVAILABLE FAULT

CURRENT=20,918A

M

SESHA-MB

480V, 1600AF/1600AT

3P, 3W, NW LSIG

NOTES 1, 2

SESHA

1600A, 480V

3PH, 4W, GFE

25,000 AIR

(ROOM 181)

QED 2

ST

N G

SESHB-MB-PB

REMOTE CONTROL

SWITCH NOTE 3

SESHB-MB

480V, 1600AF/1600AT

3P, 3W, NW LSIG

NOTES 1, 2

SESHB

1600A, 480V

3PH,4W,

GFE

25,000 AIR

(ROOM 186)

QED 2

ST

N G

049048 055

EDPHA1-

CAB-FB

LSI

USHA-

MBB-FB

LSI

UPSA-

SBB-FB

LSI

UPSA-RIB-

FB LSI

T-EDPLA-

FB LSI

NOTE 13

EDPHA1-

FB LSI

ESHA-MB

LSI

ESHA-SPD-FB

100AF,100AT,3P

ESHA

1600A, 480V

3PH, 3W, 25,000 AIR,

GFE, (ROOM 179)

QED 2

SPD

GFE NOTE 11

1600AF

1600AT

3P

800AF

400AT

3P

400AS

400AT

3P

250AS

150AT

3P

250AS

150AT

3P

250AS

150AT

3P

400AS

225AT

3P

CH-1-FB

LSI

400AS

350AT

3P 051

B-CH-1

ESHA-TB, N.O.

LSI

K1

059058 063 064

EDPHB1-

CAB-FB

LSI

USHB-MBB-

FB LSI

UPSB-SBB-

FB LSI

UPSB-RIB-

FB LSI

T-EDPLB-

FB LSI

NOTE 13

EDPHB1-

FB LSI

ESHB-MB

LSI

ESHB-SPD-FB

100AF,100AT,3P

ESHB

1600A, 480V

3PH,3W

25,000 AIR

GFE

(ROOM 185)

QED 2

SPD

GFE NOTE 11

1600AF

1600AT

3P

800AS

400AT

3P

400AS

400AT

3P

250AS

150AT

3P

250AS

150AT

3P

250AS

150AT

3P

400AS

225AT

3P

CH-2-FB

LSI

400AF

350AT

3P 061

B-CH-2

K1

ESHB-TB, N.O.

LSI K1

EDPHA2

225A, 480/277V

3PH, 4W, GFE

18,000 AIR

(ROOM 179)

I LINE

EDPHA2-MB

LI

T-EDPHA2

150KVA

480V-480Y/277V, GFE, (ROOM 179)

NOTE 19

T-EDPHA2-

FB LI

NOTE 13

EDPHA1-

MB LSI

EDPHA1

400A, 480V, 3PH,3W, GFE,

25,000 AIR

(ROOM 179)

I LINE

800AS

400AT

3P

400AF

225AT

3P

400AF

225AT

3P

SPARE

LSI

100AF

50AT

3P

SPD

EDPHA2-

SPD-FB

70AT

GFE

NOTE 29

075 EDPHB2

400A, 480/277V

3PH, 4W, GFE

18,000 AIR

(ROOM 185)

I LINE

EDPHB2-MB

LI

T-EDPHB2

150KVA

480V-480Y/277V, GFE, (ROOM 185)

NOTE 19

T-EDPHB2-

FB LI

NOTE 13

EDPHB1-

MB LSI

EDPHB1

400A, 480V, 3PH, 3W, GFE,

25,000 AIR

(ROOM 185) I LINE

800AS

400AT

3P

400AF

225AT

3P

400AF

225AT

3P

SPARE

LSI

100AF

50AT

3P

SPD

EDPHB2-

SPD-FB

70AT

GFE

NOTE 29

ATS-FLS

150A, 4P, 3W

480V, GFE

18,000 WCR

(ROOM 173)

FLSDPH1

200A, 480V, 3PH, 4W

GFE 18,000 AIR

(ROOM 173)

I LINE 045

SPD GFE

T-FLSPL-

FB

NOTE 13

FLSDPH1-

CAB-

FB LSI

100AF

20AT

2P

INV1-FB

LSI

NOTE 13

100AF

25AT

3P

FLSDPH1-SPD-FB

100AF/100AT

FLSDPH1-

MB LSI

100AS

60AT

3P

250AS

125AT

3P

NOTE 22

NOTE 22

NOTE 34

NOTE 23

NOTE 24

NOTE 22

NOTE 22

NOTE 23

NOTE 24

NOTE 22

NOTE 22

FROM COFFEE CREEK SUBSTATION

PRIMARY CIRCUIT (CIRCUIT 2406)

FROM COFFEE CREEK SUBSTATION

ALTERNATE CIRCUIT (CIRCUIT XXXX)

042 ELEV-DS-B

480V, 3P, 3W

60AF/60AT

CFE (ROOM 173)

NOTE 17043

ATS-ELEV-B,

150A,3P,3W

480V, GFE

18,000 WCR

(ROOM 173)

ELEVATOR B

CONTROLLER

NPH-

A-FB

LSIG

400AS

200AT

3P

NOTE 23

NPH-

B-FB

LSIG

250AS

200AT

3P

35 NOTE 23

ATS-FP-CB-B

480V, 3P, 3W

400AF/400AT

GFE, NOTE 2, 6

NEMA 4X S.S.

FP-2 FIRE PUMP

CONTROLLER WITH ATS

40HP, NOTE 27

1600AS, 1600AT, 3P1600AS, 1600AT, 3P

NOTE 11

FLSPL

60A, 208Y/120V

3PH, 4W, GFE

10,000 AIR

(ROOM 173)

NQOD

FLSPL-MB

LSI

T-FLSPL

15KVA

480V-208Y/120V, GFE, (ROOM 173)

NOTE 19

60AF

50AT

3P

T-FLSDPH1

75KVA

480V-480Y/277V, GFE, (ROOM 173)

NOTE 19

ATS-FP-CB-A-PB

REMOTE CONTROL

SWITCH NOTE 31

ST

ATS-FP-CB-B-PB REMOTE

CONTROL SWITCH NOTE 31

INV1

480/277V, 1PH,3W, 5KW

10,000 AIR

(ROOM 173)

NOTE 32

NOTE 33 NOTE 33

100AF

20AT

2P

BATT.

N E

N E N E N EN E

GEN-A1-

LBB

1200AF

1200AT

LSIA, PG

GEN-B1-

LBB

1200AF

1200AT

LSIA, PG

T-EPLA6

-A-FB

LSI

100AF

50AT

3P

T-EPLA6

30KVA

480V-208Y/120V, GFE, (GUARD

BOOTH) NOTE 19

T-EPLA6-DS

480V, 3P, 3W

60AF, CFE

(GUARD BOOTH)

NEMA 4X S.S.

EPLA6

100A, 208/120V

3PH, 4W, GFE

10,000 AIR

(GUARD BOOTH)

NQOD

EPLA6-MB

LSI

250AF

100AT

3P

SPD

EPLA6-

SPD-FB

100AT

GFE

NOTE 12

ATS PRIORITY SEQUENCE

UPON LOSS OF NORMAL UTILITY POWER THE ATS'S SHALL SWITCH FROM THE

NORMAL UTILITY POWER TO GENERATOR POWER WITH THE FOLLOWING PRIORITY:

1. FP-1 AND FP-2

2. ATS-FLS

3. ATS-ELEV-A, ATS-ELEV-B

4. ATS-A, ATS-B

IN THE EVENT OF A GENERATOR OVERLOAD CONDITION, THE LOADS SHOULD BE

DISCONNECTED FROM GENERATOR POWER IN REVERSE ORDER (4,3,2).

FP-2

ROOM 175

FP-1

ROOM 175

T-EPLA6-DT-DS

480V, 3P, 3W

60AF, GFE

(ROOM 179)

NOTE 8, CFE

B-AHU-1

-B-FB

LSI

400AS

200AT

3P

B-AHU-1

-A-FB

LSI

400AS

200AT

3P

B-AHU-1

B-AHU-1-DS

480V, 3P, 3W

200AF, CFE

(ROOM 177)

NOTE 8

194193

T-EPLA6

-B-FB

LSI

100AF

50AT

3P

MO

ST

MO MOMO

K1

T-FLSDPH1-DS

480V, 3P, 3W

200AF, CFE

(ROOM 173)196

CHECKED

URS project no.

Copyright © 2014 URS Corporation, All Rights Reserved

DESIGNED DATE

H

G

F

E

D

C

B

A

7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

DRAWN

APPROVED BY

JCNISSUED BY

SUBMITTED BY

SIGNATURE:

DATE:

DRAWING NO

SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALE FOR OTHER SIZES

REVIEWED BY

CLT-D-TRACO-

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

TRACON

EASTERN SERVICE AREA ATLANTA, GEORGIA

CHARLOTTE NCCHARLOTTE DOUGLAS INTERNATIONAL AIRPORT (CLT)

PROJECT/SYSTEM ENGINEER ENGINEERING MANAGER

REV APROVED

DATE

REDLINE

DATEDESCRIPTION JCN APVD

400 Northpark Town Center,1000 Abernathy Road, NE.

Suite 900 Tel. No (678)808-8800

Atlanta, Georgia 30328

Fax. (678)808-8400

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

08/31/2015

PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552

FOR OFFICIAL USE ONLY

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

1103700

110370008/31/2015 ISSUED FOR BID

8/

/2

:2 2:

A

M

8/31/2015 10:22:27 AM

15290056

JAW

KCV

E801

KCV

SINGLE LINE DIAGRAM - TRACON - CPDS TYPE 2A & 2B - 1

OF 3

085 086

T-UDPLB-FB

LSI

NOTE 13

UDPHB-CAB-FB

LSI

NOTE 13

UPSB-LBB

(N.O.)

UPSB-MIB LSI

USHB-SPD-FB, 100AF,100AT,3P

USHB-MBB

(N.O.) LSI

USHB-GMBB

(N.O.) LSI

GFE

SPD

069250AS

150AT

3P LSI

250AF

125AT

3P

250AF

150AT

3P

USHB

200A, 480V, 3PH, 3W, GFE

25,000 AIR

(ROOM 184)

QED 2

250AS

150AT

3P

250AS

150AT

3P

250AS

150AT

3PB1

B2 B1 B1

NOTE 11

STS1-FB-B

LSI

UDPLB-MB LSI

UDPLB-SPD-FB, 100AF,100AT,3P

GFE

SPD

250AF

250AT

3P

UDPLB

250A, 208V, 3PH, 4W

GFE, 10,000 AIR

(ROOM 184)

I LINE

400AS

250AT

3P

A3

NOTE 12

STS2-FB-A

LSI

250AF

250AT

3P

UDPLB-TB LSI

400AS/250AT

N.O. A3

STS2

250A, 208V, 3P, GFE,

10,000 WCR

(ROOM 184)

CPL6-FB

LSI

GFESPD

CDPL2

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 184)

I LINE

CDPL2-SPD-FB

100AF/100AT

3P

250AF

150AT

3P

CPL7-FB

LSI

250AF

150AT

3P

CPL8-FB

LSI

250AF

150AT

3P

CPL6-

MBB, N.O.

CPL6

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 197) NQOD, NOTE 28

250AF

175AT

3P

SPD

CPL6-

SPD-FB

100AT

GFE

NOTE 12

CPL6-

MB

CPL7-

MBB, N.O.

CPL7

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 193) NQOD, NOTE 25, 28

250AF

175AT

3P

SPD

CPL7-

SPD-FB

100AT

GFE

NOTE 12

CPL7-

MB

T-UDPLB

75KVA, K13

480V-208Y/120V, GFE (ROOM 184)

S2

CPL8-

MBB, N.O.

CPL8

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 196) NQOD, NOTE 25, 28

250AF

175AT

3P

SPD

CPL8-

SPD-FB

100AT

GFE

NOTE 12

CPL8-

MBP6 P7 P8

P6 P7 P8

CPL9-FB

LSI

250AF

150AT

3P

CPL9-

MBB, N.O.

CPL9

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 194) NQOD, NOTE 25, 28

250AF

175AT

3P

SPD

CPL9-

SPD-FB

100AT

GFE

NOTE 12

CPL9-

MB P9

P9

UPS-LB

100KVA

480V, 3PH, 3W

GFE, NEMA 4X S.S.

UPS-LB-DS

200A, 480V, 3P, 3W, NF,GFE

NEMA 4X S.S.

T-UDPLA-FB

LSI

NOTE 13

UDPHA-CAB-FB

LSI

UPSA-LBB

(N.O.)

UPSA-MIB LSI

USHA-SPD-FB, 100AF,100AT,3P

USHA-MBB

(N.O.) LSI

USHA-GMBB

(N.O.) LSI

GFE

SPD

080250AS

150AT

3P LSI

250AF

125AT

3P

250AF

150AT

3P

USHA

200A, 480V, 3PH, 3W, GFE

25,000 AIR

(ROOM 180)

QED 2

250AS

150AT

3P

250AS

150AT

3P

250AS

150AT

3P

A2 A1 A1

NOTE 11

UPS-A-LB-IB

LSI

LBDPH

200A, 480V, 3PH, 3W

GFE, 18,000 AIR

(ROOM 180)

I LINE

250AS

150AT

3P

KL UPS-B-LB-IB

LSI

250AS

150AT

3P

KL

LBH-FB

LSI

NOTE 35

250AS

150AT

3P

T-UDPLA

75KVA, K13

480V-208Y/120V, GFE (ROOM 180)

STS1-FB-A

LSI

UDPLA-MB LSI

UDPLA-SPD-FB, 100AF,100AT,3P

GFE

SPD

250AF

250AT

3P

UDPLA

250A, 208V, 3PH, 4W

GFE, 10,000 AIR

(ROOM 180) I LINE

400AS

250AT

3P

A3

NOTE 12

STS2-FB-B

LSI

250AF

250AT

3P

S1

UDPLA-TB LSI

400AS/250AT, N.O.

A3

CPL1-

MBB-

FB

LSI

250AF

150AT

3P

UDPLM

250A, 208V, 3PH, 4W

GFE, 10,000 AIR

(ROOM 180) I LINE

UDPLM-TB-A, LSI

400AS/250AT

CPL2-

MBB-

FB

LSI

250AF

150AT

3P

CPL3-

MBB-

FB

LSI

250AF

150AT

3P

CPL4-

MBB-

FB

LSI

250AF

150AT

3P

CPL5-

MBB-

FB

LSI

250AF

150AT

3P

CPL6-

MBB-

FB

LSI

250AF

150AT

3P

CPL7-

MBB-

FB

LSI

250AF

150AT

3P

UDPLM-TB-B, LSI

400AS/250AT

STS1

250A, 208V, 3P, GFE,

10,000 WCR

(ROOM 180)

CPL1-FB

LSI

CDPL1

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 180)

I LINE250AF

150AT

3P

CPL2-FB

LSI

250AF

150AT

3P

CPL3-FB

LSI

250AF

150AT

3P

CPL1-

MBB, N.O.

CPL1

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 197) NQOD

NOTE 28

250AF

175AT

3P

SPD

CPL1-

SPD-FB

100AT

GFE

NOTE 12

CPL1-

MB

CPL2-

MBB, N.O.

CPL2

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 190) NQOD

NOTE 25, 28

250AF

175AT

3P

SPD

CPL2-

SPD-FB

100AT

GFE

NOTE 12

CPL2-

MB

CPL3-

MBB, N.O.

CPL3

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 190) NQOD

NOTE 25, 28

250AF

175AT

3P

SPD

CPL3-

SPD-FB

100AT

GFE

NOTE 12

CPL3-

MB

CPL4-

MBB, N.O.

CPL4

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 194) NQOD, NOTE 25, 28

250AF

175AT

3P

SPD

CPL4-

SPD-FB

100AT

GFE

NOTE 12

CPL4-

MBP1 P2 P3 P4

P1 P2 P4P3

GFE

SPD

NOTE 12

UDPLM-SPD-FB, 100AF,100AT,3P

CPL8-

MBB-

FB

LSI

250AF

150AT

3P

CPL9-

MBB-

FB

LSI

250AF

150AT

3P

CPL4-FB

LSI

250AF

150AT

3P

CPL5-FB

LSI

250AF

150AT

3P

CPL5-

MBB, N.O.

CPL5

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 180) NQOD, NOTE 28

250AF

175AT

3P

SPD

CPL5-

SPD-FB

100AT

GFE

NOTE 12

CPL5-

MB P5

P5

NOTE 9

6 7 1

12 13

210 11

NOTE 21 NOTE 21 NOTE 21 NOTE 21 NOTE 21 NOTE 21

NOTE 24NOTE 24

P1

P2

P3

P4

P5

S1

S2

P7

P8

P9

P6

NOTE 26 NOTE 26

056 017

064 029

123 124

NOTE 28 NOTE 28 NOTE 28 NOTE 28 NOTE 28

NOTE 28 NOTE 28 NOTE 28 NOTE 28

A2

NOTE 12

A1

B2

GFESPD

CDPL1-SPD-FB

100AF/100AT

3P

NOTE 12

SOURCE 1 SOURCE 2 SOURCE 1 SOURCE 2

CHECKED

URS project no.

Copyright © 2014 URS Corporation, All Rights Reserved

DESIGNED DATE

H

G

F

E

D

C

B

A

7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

DRAWN

APPROVED BY

JCNISSUED BY

SUBMITTED BY

SIGNATURE:

DATE:

DRAWING NO

SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALE FOR OTHER SIZES

REVIEWED BY

CLT-D-TRACO-

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

TRACON

EASTERN SERVICE AREA ATLANTA, GEORGIA

CHARLOTTE NCCHARLOTTE DOUGLAS INTERNATIONAL AIRPORT (CLT)

PROJECT/SYSTEM ENGINEER ENGINEERING MANAGER

REV APROVED

DATE

REDLINE

DATEDESCRIPTION JCN APVD

400 Northpark Town Center,1000 Abernathy Road, NE.

Suite 900 Tel. No (678)808-8800

Atlanta, Georgia 30328

Fax. (678)808-8400

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

08/31/2015

PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552

FOR OFFICIAL USE ONLY

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

1103700

110370008/31/2015 ISSUED FOR BID

8/

/2

:2 2:

A

M

8/31/2015 10:22:29 AM

15290056

JAW

KCV

E802

KCV

SINGLE LINE DIAGRAM - TRACON - CPDS TYPE 2A & 2B - 2

EPLB1-

MB

EPLB1

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 194) NQOD, NOTE 7

250AF

150AT

3P

SPD

EPLB1-

SPD-FB

100AT

GFE

NOTE 12

EPLB1-

MBB,N.O.

EPLB2-

MB

EPLB2

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 185) NQOD

250AF

150AT

3P

SPD

EPLB2-

SPD-FB

100AT

GFE

NOTE 12

EPLB2-

MBB,N.O.

EPLB3-

MB

EPLB3

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 188) NQOD

250AF

150AT

3P

SPD

EPLB3-

SPD-FB

100AT

GFE

NOTE 12

EPLB3-

MBB,N.O.

EPLB4-

MB

EPLB4

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 140) NQOD

250AF

150AT

3P

SPD

EPLB4-

SPD-FB

100AT

GFE

NOTE 12

EPLB4-

MBB,N.O.E6

E6

E7

E7

E8

E8EPLA1-

MBB, N.O.

EPLA1

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 197) NQOD

250AF

150AT

3P

SPD

EPL1-

SPD-FB

100AT

GFE

NOTE 12

EPLA1-

MB

EPLA2-

MBB, N.O.

EPLA2

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 179) NQOD

250AF

150AT

3P

SPD

EPL2-

SPD-FB

100AT

GFE

NOTE 12

EPLA2-

MB

EPLA3-

MBB, N.O.

EPLA3

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 188) NQOD, NOTE 7

250AF

150AT

3P

SPD

EPL3-

SPD-FB

100AT

GFE

NOTE 12

EPLA3-

MB

EPLA4-

MBB, N.O.

EPLA4

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 194) NQOD

250AF

150AT

3P

SPD

EPL4-

SPD-FB

100AT

GFE

NOTE 12

EPLA4-

MBE1

E1 E2

E2 E3

E3 E4

E4

14 24 15 25 16 26 17 27 29 19 30 20 31 21 32 22NOTE 23NOTE 23

NPL-A

250A, 208/120V

3PH, 4W, GFE

10,000 AIR

(ROOM 177)

I LINE

NPL-A-MB

LSI

T-NPLA

45KVA

480V-208Y/120V, GFE, (ROOM 140)

NOTE 19

T-NPLA-

FB LSI

NOTE 13

NPH-A-

MB LSI

NPH-A

250A, 480V, 3PH, 3W, GFE,

18,000 AIR

(ROOM 177)

I LINE

200AF

200AT

3P

250AF

150AT

3P

100AF

70AT

3P

SPD

NPL-A-

SPD-FB

100AT

GFE

NOTE 12

34 NOTE 21

NPL-B

250A, 208/120V

3PH, 4W, GFE

10,000 AIR

(ROOM 140)

I LINE

NPL-B-MB

LSI

T-NPLB

45KVA

480V-208Y/120V, GFE, (ROOM 177)

NOTE 19

T-NPLB-

FB LSI

NOTE 13

NPH-B-

MB LSI

NPH-B

250A, 480V, 3PH, 3W, GFE,

18,000 AIR

(ROOM 140)

I LINE

200AF

200AT

3P

250AF

150AT

3P

100AF

70AT

3P

SPD

NPL-B-

SPD-FB

100AT

GFE

NOTE 12

35 NOTE 21

007 039

EPLA1-

FB

EPLA2-

FB

EPLA3-

FB

EPLA4-

FB

EDPLA

800A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 179)

I LINE

EDPLA-SPD-FB

100AF,100AT,3P

EDPLA-

MB LSI

GFESPD

EPLB1-

MBB-

FB

800AF

500AT

3P

250AF

150AT

3P

250AF

150AT

3P

250AF

150AT

3P

250AF

150AT

3P

250AF

150AT

3P

EPLB2-

MBB-

FB

250AF

150AT

3P

EPLB3-

MBB-

FB

250AF

150AT

3P

EPLB4-

MBB-

FB

250AF

150AT

3P

14 15 16 17 19 20 21

NOTE 21

NOTE 23NOTE 23NOTE 23NOTE 23NOTE 23NOTE 23NOTE 23NOTE 23

089 090 091 092 093 094 095 096

NOTE 12

EPLA1-

MBB-FB

EPLA2-

MBB-FB

EPLA3-

MBB-FB

EPLA4-

MBB-FB

EDPLB

800A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 185)

I LINE

EDPLB-SPD-FB

100AF,100AT,3P

EDPLB-

MB LSI

GFESPD

EPLB1-

FB

800AF

500AT

3P

250AF

150AT

3P

250AF

150AT

3P

250AF

150AT

3P

250AF

150AT

3P

250AF

150AT

3P

EPLB2-

FB

250AF

150AT

3P

EPLB3-

FB

250AF

150AT

3P

EPLB4-

FB

250AF

150AT

3P

24 25 26 27 28 29

NOTE 21

NOTE 23 NOTE 23 NOTE 23 NOTE 23 NOTE 23 NOTE 23 NOTE 23 NOTE 23

101 102 103 104 105 106 107 108

NOTE 12

EPLB5-

MB

EPLB5

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 187) NQOD

250AF

150AT

3P

SPD

EPLB5-

SPD-FB

100AT

GFE

NOTE 12EPLB5-

MBB,N.O.E9

E9EPLA5-

MBB, N.O.

EPLA5

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 182) NQOD

250AF

150AT

3P

SPD

EPL5-

SPD-FB

100AT

GFE

NOTE 12EPLA5-

MBE5

E5

EPLA5-

MBB-FB

250AF

150AT

3P

NOTE 23

EPLB5-

FB

250AF

150AT

3P

NOTE 23

33 2318 28

EPLA5-

FB

250AF

150AT

3P

18 NOTE 23

EPLB5-

MBB-

FB

250AF

150AT

3P

23 NOTE 2322 30 31 32

NOTE 23NOTE 23 NOTE 23NOTE 23 NOTE 23NOTE 23 NOTE 23NOTE 23 NOTE 23NOTE 23 NOTE 23NOTE 23 NOTE 23NOTE 23 NOTE 23NOTE 23 NOTE 23NOTE 23

175 176E10

E10

CHECKED

URS project no.

Copyright © 2014 URS Corporation, All Rights Reserved

DESIGNED DATE

H

G

F

E

D

C

B

A

7 6 5 4 3 2 1

H

G

F

E

D

C

B

A

8 7 6 5 4 3 2 1

DRAWN

APPROVED BY

JCNISSUED BY

SUBMITTED BY

SIGNATURE:

DATE:

DRAWING NO

SCALES SHOWN FOR 22" X 34" SHEET. ADJUST SCALE FOR OTHER SIZES

REVIEWED BY

CLT-D-TRACO-

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

TRACON

EASTERN SERVICE AREA ATLANTA, GEORGIA

CHARLOTTE NCCHARLOTTE DOUGLAS INTERNATIONAL AIRPORT (CLT)

PROJECT/SYSTEM ENGINEER ENGINEERING MANAGER

REV APROVED

DATE

REDLINE

DATEDESCRIPTION JCN APVD

400 Northpark Town Center,1000 Abernathy Road, NE.

Suite 900 Tel. No (678)808-8800

Atlanta, Georgia 30328

Fax. (678)808-8400

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

08/31/2015

PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552

FOR OFFICIAL USE ONLY

DISCIPLINE: ELECTRICAL

NAME: KUNG C. VEN

NORTH CAROLINA REG. #: 036451

ELECTRICAL

1103700

110370008/31/2015 ISSUED FOR BID

8/

/2

:2 2:

A

M

8/31/2015 10:22:31 AM

15290056

JAW

KCV

E803

KCV

SINGLE LINE DIAGRAM - TRACON - CPDS TYPE 2A & 2B - 3

T-EDPHA2-

CAB-FB

LSI, NOTE 1

EDPHA1-CAB-MB

LSI

EDPHA1-CAB-SPD-FB

100AF/100AT

3P

GFESPD

EDPHA1-CAB

400A, 480V, 3PH,3W,

GFE

18,000 AIR

(ROOM 1209)

I LINE 400AF

175AT

3P

250AF

125AT

3P

T-EDPLA-

CAB-FB

LSI, NOTE 1

400AS

400AT

3P

SPARE-

FB

003 006

T-UDPLA-

CAB-FB, LSI

NOTE 1

UDPHA-CAB-MB

LSI

UDPHA-CAB-SPD-FB

100AF/100AT

3P

GFESPD

UDPHA-CAB

250A, 480V, 3PH,3W,

GFE

18,000 AIR

(ROOM 1208)

I LINE 250AF

125AT

3P

SPARE-

FB

400AS

150AT

3P

SPARE-

FB

T-UDPLB-

CAB-FB, LSI

NOTE 1

UDPHB-CAB-MB

LSI

UDPHB-CAB-SPD-FB

100AF/100AT

3P

GFESPD

UDPHB-CAB

250A, 480V, 3PH, 3W,

GFE

18,000 AIR

(ROOM 1208)

I LINE 250AF

125AT

3P

SPARE-

FB

400AS

150AT

3P

SPARE-

FB

T-EDPHB2-

CAB-FB

LSI,NOTE 1

EDPHB1-CAB-MB

LSI

EDPHB1-CAB-SPD-FB

100AF/100AT

3P

GFESPD

EDPHB1-CAB

400A, 480V, 3PH, 3W, GFE

18,000 AIR

(ROOM 1209)

I LINE 400AF

175AT

3P

250AF

125AT

3P

T-EDPLB-

CAB-FB

LSI,NOTE 1

400AS

400AT

3P

SPARE-

FB

T-EDPHA2-CAB

112.5KVA

480V-480Y/277V, GFE (ROOM 1209)

T-EDPHB2-CAB

112.5KVA

480V-480Y/277V, GFE (ROOM 1209)

T-EDPLA-CAB

75KVA

480V-208Y/120V, GFE (ROOM 1209)

T-UDPLA-CAB

75KVA

480V-208Y/120V, GFE (ROOM 1208)

T-UDPLB-CAB

75KVA

480V-208Y/120V, GFE (ROOM 1208)

T-EDPLB-CAB

75KVA

480V-208Y/120V, GFE (ROOM 1209)

GENERAL NOTES

KEYED NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

EDPHA2-CAB

-MB LSI

EDPHA2-CAB,

200A, 480/277V, 3PH, 4W, GFE,

18,000 AIR

(ROOM 1209)

I LINE

250AF

175AT

3P

EDPHA2-CAB-

SPD-FB

100AF, 70AT, 3P

GFE SPD

045 047

EPLA1-

CAB-

FB

EDPLA-CAB

250A, 208/120V, 3PH, 4W, GFE,

10,000AIR

(ROOM 1209) I LINE

250AF

150AT

3P

EPLA2-

CAB-

FB

EPLA3-

CAB-

FB

250AF

150AT

3P

250AF

150AT

3P

EDPLA-CAB-MB LSI

400AF/250AT, 3P

EDPHB2-

CAB-MB

LSI

EDPHB2-CAB,

200A, 480/277V, 3PH, 4W, GFE,

18,000 AIR

(ROOM 1209)

I LINE

250AF

175AT

3P

EDPHB2-CAB-

SPD-FB

100AF, 70AT, 3P

GFE SPD

035 036 037

EPLA1-

CAB-MBB-

FB

EDPLB-CAB

250A, 208/120V, 3PH, 4W, GFE,

10,000AIR

(ROOM 1209)

I LINE

250AF

150AT

3P

EPLA2-

CAB-MBB-

FB

EPLA3-

CAB-MBB-

FB

250AF

150AT

3P

250AF

150AT

3P

EDPLB-CAB-MB LSI

400AF/250AT, 3P

UDPLA-CAB

-MB LSI

UDPLA-CAB,

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 1208)

I LINE

250AF

250AT

3P

UDPLA-CAB-

SPD-FB

100AF, 70AT, 3P

SPD

STS1-

CAB-

FB-A

LSI

UDPLM-CAB,250A, 208/120V, 3PH, 4W,

GFE,10,000 AIR (ROOM 1208)

I LINE

UDPLM-CAB-

SPD-FB

100AF, 70AT, 3P

SPD

CPL1-

CAB

MBB-FB

250AF

150AT

3P,LSI

020 022 STS1-CAB

150A,208V, 3P, GFE

10,000 AIR

(ROOM 1208)

NOTE15

250AF

150AT

3P

S3

CPL1-

CAB-

FB LSI

250AF

150AT

3P

CDPL1-CAB

250A, 208/120V, 3PH,

4W, GFE,

10,000AIR

(ROOM 1208) I LINE

CPL8-CAB-

MBB, N.O.

CPL8-CAB

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 1109) NQOD, NOTE 14

250AF

175AT

3P

SPD

CPL8-

CAB-

SPD-FB

100AT

GFE

NOTE 2

CPL8-

CAB-

MB P17

P17

CPL5-CAB-

MBB, N.O.

CPL5-CAB

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 1405) NQOD, NOTE 14

250AF

175AT

3P

SPD

CPL5-

CAB-

SPD-FB

100AT

GFE

NOTE 2

CPL5-

CAB-

MB P14

P14

CPL6-CAB-

MBB, N.O.

CPL6-CAB

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 1405) NQOD, NOTE 14

250AF

175AT

3P CPL6-

CAB-

SPD-FB

100AT

CPL6-

CAB-

MB P15

P15

EPLA1-CAB-

MBB, N.O.

EPLA1-CAB

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 1209)

NQOD

250AF

150AT

3P

SPD

EPLA1-CAB-

SPD-FB

100AT

GFE

NOTE 2

EPLA1-

CAB-

MB E11

E11

EPLA2-CAB-

MBB, N.O.

EPLA2-CAB

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 1109) NQOD

250AF

150AT

3P

SPD

EPLA2-

CAB-

SPD-FB

100AT

GFE

NOTE 2

EPLA2-

CAB-

MB E12

E12

EPLA3-CAB-

MBB, N.O.

EPLA3-CAB

250A, 208/120V, 3PH, 4W, GFE,

10,000 AIR

(ROOM 1403) NQOD

250AF

150AT

3P

SPD

EPLA3-

CAB-

SPD-FB

100AT

GFE

NOTE 2

EPLA3-

CAB-

MB E13

E13

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

REFER TO SHEETS E500 SERIES FOR PANEL SCHEDULES FOR SIZES AND QUANTITY OF SPARE

BREAKERS AND ADDITIONAL PREPARED SPACES FOR ALL EQUIPMENT.

PROVIDE FINAL ADJUSTMENTS OF RATINGS AND SETTINGS FOR ALL EQUIPMENT PER SHORT

CIRCUIT, ARC FLASH, AND COORDINATION CALCULATIONS. CONTRACTOR TO FIELD VERIFY

CABLE LENGTH AND SUBMIT TO FAA, AND ADJUST FEEDER CONDUCTOR AND CONDUIT SIZES AS

NECESSARY TO ACCOMMODATE FIELD CONDITIONS FOR VOLTAGE DROPS, AND DERATING FOR

BELOW SLAB, ETC. ADJUST FEEDER AND CONDUIT SIZES TO MATCH LUG SIZE ON

PANELBOARDS, SWITCHBOARDS AND SWITCHGEAR. PROVIDE ARC FLASH LABELING FOR

EQUIPMENT. SEE SHORT CIRCUIT COORDINATION STUDY TO BE PERFORMED BY SQUARE D.

ALL BREAKERS AND SWITCHES SHALL BE IN NORMALLY CLOSED POSITION UNLESS OTHERWISE

NOTED.

TRANSFORMER DISCONNECTS SHALL BE LOCATED WITHIN 50 FEET OF TRANSFORMER.

LOCATE SPD…