Amendment 0002 - NY FLAP DOT 63(1).pdf
PDF 793 KB Posted
- Attached to
- Roadway Improvements to NYS Route 63
- Solicitation number
- 693C73-23-B-000012
About this file
This amendment to a federal solicitation provides revisions to plans and specifications and reschedules the bid opening date for a roadway improvements project on NYS Route 63. The Eastern Federal Lands Highway Division of the Federal Highway Administration issued Solicitation 693C73-23-B-000012 seeking bids to improve 5.7 miles of Route 63 located in Franklin County, New York. The amendment revises wingwall details on plans sheets, responds to twenty-seven questions from prospective bidders, and reschedules the bid opening from July 27, 2023 to August 8, 2023 at 2:00 PM EDT. Work under the contract includes design and construction of three box culverts and associated drainage features.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(x)
693C7323B000012 x x
1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR
OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
ASHBURN VA 20147
ATTN: Construction
693C73
SUITE E2-3-300
QUANTUM PARK, 22001 LOUDOUN COUNTY PKWY
EASTERN FEDERAL LANDS HIGHWAY DIVISION
FEDERAL HIGHWAY ADMINISTRATION
ASHBURN VA 20147
ATTN: Acquisitions
693C73
SUITE E2-3-300
QUANTUM PARK, 22001 LOUDOUN COUNTY PKWY
EASTERN FEDERAL LANDS HIGHWAY DIVISION
FEDERAL HIGHWAY ADMINISTRATION
See Block 1407/27/20230002
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
07/03/2023
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Project NY FLAP DOT 63(1)
The purpose of this Amendment is to:
1) Provide a summary of responses to questions/clarifications asked by potential bidders.
2) Revise plans sheets as follows:
a) Plans sheets K01 and K02 - Proposed wingwall callout revised to reference detail E602-C.
3) Reschedule the Bid Opening date to August 8, 2023, at 2:00 p.m. EDT.
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
Amendment No. 0002
U.S. DEPARTMENT OF TRANSPORTATION
FEDERAL HIGHWAY ADMINISTRATION
EASTERN FEDERAL LANDS HIGHWAY DIVISION
Project NY FLAP DOT 63(1)
Roadway Improvements to NYS Route 63
Solicitation: 693C73-23-B-000012
The purpose of this Amendment is to:
1) Provide a summary of responses to questions/clarifications asked by potential bidders.
2) Revise plans sheets as follows:
a) Plans sheets K01 and K02 – Proposed wingwall callout revised to reference detail
E602-C.
3) Reschedule the Bid Opening date to August 8, 2023, at 2:00 p.m. EDT.
Questions / Clarifications
The following questions and issues were submitted to EFLHD at eflhd.conracts@dot.gov. The
Government response or clarification is provided. Due to the repetitive nature of several questions and issues, the wording of the questions may have been revised and some questions have not been included.
The Government’s direct response to the sender may also have been updated below for better clarity.
1) Detail for 14” prestressed piling:
Response: Pile design and layout is included with the 55101-0600 (Precast Prestressed
Concrete Pile) pay item, contractor is responsible for determining the final length and location of the piles for the design.
2) Piling layout in construction plan:
Response: Pile design and layout is included with the 55101-0600 (Precast Prestressed
Concrete Pile) pay item, contractor is responsible for determining the final length and location of the piles for the design.
3) PDA requirements for pile driving:
Response: Refer bidder to FP-14 Section 551.
4) Pile cutoff information:
Response: Refer bidder to Subsection 551.14.
5) Pile driving criteria:
Response: Refer bidder to FP-14 Section 551 and latest version of AASHTO LRFD Section
10. Contractor is responsible for the design of the piles.
../../../../../../../natr/1e10/Proj_Dev/Eng_Coord/3Advertisement/Amendments/Amendment%201/Final%20Documents/eflhd.conracts@dot.gov
6) SCR 201.05A section C requires contractor to extend excavation to a minimum depth of 6 feet below proposed grade for clearing and grubbing. Is this accurate?
Response: See Amendment #1 for revised Section 201 of SCR to clarify that are two different methods for the removal of invasive species.
7) SCR 107.10(c) states to verify the presence or absence of invasive species prior to conducting work. Is this the contractors responsibility?
Response: Correct this would be the contractor's responsibility. The plans do provide some locations of invasive species.
8) SCR 156.04 states to maintain one lane of traffic at all times. Is there no exception to this?
Response: Refer bidder to Subsection 156.04 of the SCR.
9) On sheet S12, Designer note #4 refers to a foundation design report. Is there a foundation design report available for review or is this actually referring to the final design report? Response: Sheet
S12 is a NYDOT Standard Drawing to provide general guidance for the Contractors
Design. Boring logs were provided as Government Furnished Information for the project advertisement.
10) The plans refer to steel piles, the bid schedule refers to concrete piles and the final design report refers to timber piles for the box culverts. Is this up to the contractor to determine which type of pile to use?
Response: Provide bids based on the pay items (concrete piles) shown in the advertised documents bid schedule. After the project is awarded a Value Engineering proposal can be submitted to the CO for possible approval, as described under FP Subsection 103.03.
11) Is sheet S13 missing from the plans? Our plan set goes from S12 to S14.
Response: There is no S13 sheet.
12) The details and dimensions in the plans are in general, vague. Can you provide the engineers quantity computations to help us better understand the intent whereby the pay item quantities were derived?
Response: Provide bids based on the advertised documents. No quantity calculations will be provided.
13) Will a Gant chart be an acceptable scheduling method in lieu of a CPM schedule submission?
Response: CPM schedules are not required according to section 155.05 of the Special
Contract Requirements. The contractor is to provide a Bar Chart Method schedule in accordance with section 155.
14) With the maintaining of one open lane at all times during construction, can we request night time work during the critical excavation components?
Response: Refer bidder to Section 156.08 of the SCR.
15) Will the contractor be allowed to shift traffic over a temporary culvert outside the normal edge of pavement in order to phase construction on the box culverts?
Response: Provide bids based on the advertised documents. The Government will not recommend or approve means and methods during the advertisement of the project.
16) Based on Spec Book Section 104, please confirm that the expectation is for the Contractor to hire and supply a certified PE to design all the structural work including the piling system?
Response: Correct per Section 104 of the FP.
17) Section 157 requires weekly erosion inspection reports. Will the contractor or CO perform the weekly erosion control inspections and reports?
Response: Refer bidder to Section 157.14 of the FP.
18) There is no phasing plan or centerline shoring shown for the culverts. Does the CO expect that we will be closing the road and detouring traffic during the culvert installations? If no road closure is allowed, what is the desired process for shoring at centerline?
Response: Refer bidder to Subsection 602.03. The contractor is to follow OSHA safety regulations 29 CFR, Part 1926, Subpart P.
19) Will the contractor be allowed to install a carrier pipe for dewatering purposes under the existing road and then abandon in place?
20) The drainage summary table on sheet C02 shows 29.0 cy of structural concrete, class A pay item
55201-0200. Where are the footing dimensions to back up these quantities?
Response: Footing dimensions for quantities were developed based on the NYDOT
Standard Plan sheets in relation to the size of the culvert. The Contractor’s designer will need to determine the final dimensions based on the design requirements.
21) If the contractor is to provide the design and dimensions for the box culverts and foundations will they be required to utilize the deep foundation pile and strip footing system? Will the contractor be allowed to choose the invert slab with keyway option as shown on sheet S11? If the contractor chooses the invert slab option, what pay items would be utilized for payment since there are no piles and strip footings?
22) There appears to be an intended design for the culvert foundations because specific item numbers and quantities are given but yet the design is left up to the contractor. If the contractor is to abide by the stated items and quantities then the department’s design must be provided. If the department’s design is not provided and is left up to the contractor, by what means will payment be made when the contractors design does not align with the given items and quantities?
Response: The Contractor’s designer will need to determine the final design to meet the design loading. Payment will be made based on the final constructed quantities.
23) Will NYSDOT approved mix designs for asphalt be acceptable?
Response: Refer bidder to Section 401 of the SCR.
24) Sheets K01 and K02 call out wingwalls as shown on E602-D which will not work correctly with a 3 sided span unit on strip footings. Sheets D02, D07 and D08 call out wingwalls as shown on
E602-C. Please clarify which detail is intended for installation.
Response: Changed Detail callout from E602-D to E602-C. See amendment #2
25) If we are responsible for designing the piling system for the culverts can steel piles be utilized in lieu of concrete piles since concrete piles are not usually available in western NY?
Response: Provide bids based on the pay items (concrete piles) shown in the advertised documents bid schedule. After the project is awarded a Value Engineering proposal can be submitted to the CO for possible approval, as described under FP Subsection 103.03.
26) Please clarify which class of RCP pipe is required for the 24” culvert pipe.
27) Please provide the dimensions of the existing box culverts at station 156+04, 225+32 and 245+17 so that a centerline of road piling system can be designed around and over the existing culverts.
Response:
CIN: C410048 15ft span by 4.6ft rise by 26ft long
CIN: C116868 8ft span by 3.5ft rise by 29ft long
CIN: C116888 10 ft span by 2.5ft rise by 28ft long
156+04 - CIN 410048
150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
580 580
590 590
600 600
610 610
620 620
630 630
618.57Des Grade =
19' Span x 7' Rise x 40' Length Three Sided Precast Reinforced Concrete Box Culvert
See Detail E556-A Install Bridge Railing, Steel, Two Rail (typ.)
See Detail E602-C Install 10' Wingwall at a 70° Angle (typ.)
Flowline Invert Outlet Elevation = 611.20'
Flowline Invert Inlet Elevation = 611.25'
Elevation = 609.25' Bottom of Box Culvert
Existing Ground Surface
Install Box Culvert. See Notes and Detail E602-A
Slope 0.125%
Elevation = 609.20' Bottom of Box Culvert
Native Streambed Material
See Detail E253-A Wildlife Benching (not shown for clairity) Depth = 24"
Embedment
W RExisting Right-of-Way (Typ.)
Finished Ground/Bottom of Waterway
W R
(Future work done by others) Estimated Invert Elevation = 604' Proposed 20" Sanitary Force Main
-2.0% 1:10 -2.0%1:10
209+84 - CIN 151391
150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
590 590
600 600
610 610
620 620
630 630
618.39Des Grade =
24-Inch x 60 Feet Pipe Culvert
Existing Ground Surface
See Detail ET 601-4 Install Concrete, Headwall (typ.)
Invert Inlet Elevation = 614.11'
See Detail ET 602-07 Install 24" Pipe Culvert
Invert Outlet Elevation = 613.07'
Finished Ground/Bottom of Waterway
W RExisting Right-of-Way (Typ.)
W R
(Future work done by others) Estimated Invert Elevation = 608.50' Proposed 20" Sanitary Force Main
DRAINAGE CROSS SECTIONS
ROADWAY IMPROVEMENT TO ROUTE 63
FHWA, Office of Federal Lands Highway
SCALE IN FEET
0 10 20 for review and approval according to subsection 104.03.
all reinforcement, and submit design drawings to the CO Design concrete box culvert, headwalls, and wingwalls, including 3.
Field verify all dimensions.2.
Furnish Waterproofing Membrane according to Section 559.1.
NOTES:
Bevel concrete box culvert 1 inch along inside edge at culvert entrance.6.
Provide a minimum cover of 6 inches over the culvert.5.
incidental to diversion channel pay item.
Provide dry excavation using diversion channel. Dewatering is 4.
to reference Detail E602-C.
AMD #0002 - Proposed wingwall callout revised
NO. DATE BY REVISIONS
06/26/23 JGA1
-2.0% -2.0%1:5 1:12
Slope 1.73%
STATE PROJECT
NUMBER
SHEET
NY NY FLAP DOT 63(1) K01
2:31 PM 26 July 2023 ]K01 - Sheet [M:\PROJECTS\_ACCESS\NY\Projects\NY 04_NY FLAP DOT 63(1)\Proj_Dev\CADD\K01-K02-NY-FLAP_DOT_63-1_DRG_XS_AMEND0001.dgn
225+32 - CIN 116868
150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
590 590
600 600
610 610
620 620
630 630
618.14Des Grade =
617.89Subgrade =
Embeded Depth = 36"
See Detail E602-C
Install 5' Wingwall at a 70° Angle (typ.)
Flowline Invert Inlet Elevation = 612.30'
Elevation = 609.30'
Bottom of Box Culvert
Flowline Invert Outlet Elevation = 612.20'
Elevation = 609.20'
Bottom of Box Culvert
Install Box Culvert. See Notes and Detail E602-B
Existing Ground
10' Span x 6' Rise x 50' Length Three Sided Precast Reinforced Concrete Box Culvert
Slope 0.2%
Material
Native Streambed
W
RExisting Right-of-Way (Typ.)
W
R
Finished Ground/Bottom of Waterway
(Future work done by others) Estimated Invert Elevation = 607' Proposed 20" Sanitary Force Main
-2.0% -2.0%1:13 1:16
245+17 - CIN 116888
150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
590 590
600 600
610 610
620 620
630 630
620.43Des Grade =
Embeded Depth = 36"
Flowline Invert Inlet Elevation = 614.50'
Elevation = 611.50' Bottom of Box Culvert
Install Box Culvert. See Notes and Detail E602-B
Finished Ground/Bottom of Waterway
Slope 0.2%
Flowline Invert Outlet Elevation = 614.40'
Elevation = 611.40' Bottom of Box Culvert
See Detail E602-C Install 5' Wingwall at a 70° Angle (typ.)
Existing Ground Surface
10' Span x 6' Rise x 48' Length Three Sided Precast Reinforced Concrete Box Culvert
Material Native Streambed
W R
W RExisting Right-of-Way (Typ.)
(Future work done by others) Estimated Invert Elevation = 606.50' Proposed 20" Sanitary Force Main
DRAINAGE CROSS SECTIONS
ROADWAY IMPROVEMENT TO ROUTE 63
FHWA, Office of Federal Lands Highway
SCALE IN FEET
0 10 20
NOTES:
for review and approval according to subsection 104.03.
all reinforcement, and submit design drawings to the CO Design concrete box culvert, headwalls, and wingwalls, including 3.
Field verify all dimensions.2.
Furnish Waterproofing Membrane according to Section 559.1.
Bevel concrete box culvert 1 inch along inside edge at culvert entrance.5.
Provide a minimum cover of 6 inches over the culvert.4.
to reference Detail E602-C.
AMD #0002 - Proposed wingwall callout revised
NO. DATE BY REVISIONS
06/26/23 JGA1
-2.0% -2.0%1:6 1:6
STATE PROJECT
NUMBER
SHEET
NY NY FLAP DOT 63(1) K02
2:32 PM 26 July 2023 ]K02 - Sheet [M:\PROJECTS\_ACCESS\NY\Projects\NY 04_NY FLAP DOT 63(1)\Proj_Dev\CADD\K01-K02-NY-FLAP_DOT_63-1_DRG_XS_AMEND0001.dgn