This is an Amendment of Solicitation/Modification of Contract (Standard Form 30) issued by the GLS Contracting Office in Massena, NY for solicitation 6923G526R0094. The amendment, numbered A00006 with an effective date of 09/24/2026, revises answers to previously asked questions and updates specification section 323119. The due date for proposals remains unchanged. The amendment clarifies requirements for an ornamental security fence project.

Key revisions include: (1) the corrected concrete foundation depth is 5' 6" with a 12" diameter (revised from the previous answer regarding the initial 8' deep specification); (2) confirmation that the fence is meant to match the aesthetics of the adjacent Visitor Center, with the fence panel being slightly different but visually compatible; (3) specification that post size should be 3" Square as a function of fence height; and (4) clarification that offerors may use the basis of design product or an equivalent product with less stringent foundation requirements, provided foundations meet the minimum depth below frost line of 5' and comply with supplier requirements. All other terms and conditions remain unchanged, and the amendment requires no contractor signature or return.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

Previous edition unusable

2. AMENDMENT/MODIFICATION NUMBER

6923G526R0094 A00006

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

The purpose of this amendment is to:

1. Revise the answer for question 6 that was answered in amendment A00005. Answer an additional question received and revise spec section 323119. All specification sections and drawings not explicitly revised by this amendment remain unchanged from the original solicitation or previous amendments.

2. All other terms and conditions remain unchanged. The due date for proposals remains unchanged.

GLS Contracting Office 180 Andrews Street Massena, NY 13662

6923G526R0094

1 2

09/24/2026

08/27/2026

X X

--CONTINUATION PAGE -

The purpose of this amendment is to answer the following questions:

• Revision to Question #6 from amendment A00005:

6.) Q: For the ornamental security fence. The foundations called for are gigantic vs a typical foundation, probably uses 5X as much concrete & labor. Our equipment can not dig to that depth either, so I’d have to sub out. Any consideration to a more normal sized foundation? 4’ deep X 12” diameter?

• A: The Echelon II fence matches the Visitor’s Center fence. Their requirements call for 8’ deep as shown in the attached product data. There is a possibility for a shallower foundation with closer (6’) post spacing as opposed to the 8’. Still less concrete overall at 8’ spacing though. Offerors can utilize the basis of design product or an equivalent product with less stringent foundation requirements would also be acceptable, as long as the foundations are at least down below frost depth of 5’ and meet supplier requirements.

• REVISED ANSWER: The correct concrete depth is 5' 6". Correct diameter is 12".

• Q:The specification it says under 2.1.A “basis of design for the fencing system is specifically selected to match the aesthetics of the adjacent Visitor Center.” Can you confirm if that is the fence that this one is meant to match? If so, by my records it does not quite match what is in your specification. This specification also does not qualify post size.

A: The fence panel itself is slightly different from the one at the Visitor Center but it still matches the aesthetics. Post size should be 3" Square. The size is a function of the height, so it should match the existing Visitor’s Center as long as they select that manufacturer. Should they select a different manufacturer, their post size may vary and we’ll need to evaluate if that feature is one of those that are salient to the determination.