This is an Amendment of Solicitation/Modification of Contract (Standard Form 30) issued by GLS Contracting Office in Massena, NY for Contract ID 6923G526R0094, effective September 23, 2026. The amendment addresses questions received regarding fence specifications and provides clarifications on temporary and permanent fence requirements.

For temporary fencing, the amendment confirms that panel base fences with sandbags are required (not driven posts), temporary gates should be a minimum of 10 feet wide (not motorized), and privacy screens are acceptable as an alternative to slats. For permanent fencing, the amendment clarifies that the ornamental aluminum security fence panels may be 6 feet or 8 feet wide at contractor discretion, Specification 323113 regarding vinyl-coated chain link is not relevant, and foundation depths must be at least 5 feet below frost depth with closer post spacing (6 feet) as an alternative to the specified 8-foot spacing with deeper foundations. Offerors may use the basis of design product or equivalent products with less stringent foundation requirements, provided they meet minimum frost depth requirements and supplier specifications. The amendment includes attached Echelon II product data. All other terms and conditions remain unchanged, and the due date for proposals is unchanged. Acknowledgment of receipt by offerors is required prior to the specified hour and date.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

Previous edition unusable

2. AMENDMENT/MODIFICATION NUMBER

6923G526R0094 A00005

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

The purpose of this amendment is to:

1. Answer the following questions received on the following continuation page. Echelon II product data is also attached.

2. All other terms and conditions remain unchanged. The due date for proposals remains unchanged.

GLS Contracting Office 180 Andrews Street Massena, NY 13662

6923G526R0094

1 2

09/23/2026

08/27/2026

X X

--CONTINUATION PAGE -

The purpose of this amendment is to answer the following questions:

• 1.) Q: Notes on C001 & Spec. 015000 have several reference to “movable” or “portable.” Plans say to refer to the details on CS501…although that detail calls for “panel base and sandbags” it is depicted like a fence that would have driven posts though. Temporary fence typically has driven posts with the mesh stretched continuously or individual panels on stands. A: We want panel base fences with sandbags.

• 2.) Q: Gates? CD101 requests a 24’ wide gate. Detail 1/ CS501 shows a 10’ wide DSG. Pedestrian Gate detail 4/ CS501 is constructed like a permanent SSG. Spec.

015000; 1.5.B is calling for a temporary gate to be “motorized”? A: We do not require a motorized temporary gate. The temporary gate should be a minimum of 10' wide.

• 3.) Q: Privacy intent? Spec 015000; 1.5 calls for slats. Slats are very time consuming & expensive. Also, they would not be practical if going in panels. Is privacy screen an option? That too is not ideal on panels though. A: A privacy screen is acceptable.

Permanent fence:

• 4.) Q: “Security Fence see specification 323119” on CS101. This is an industrial ornamental aluminum fence. There are no details for it nor do I see post spacing in the specification. The manufacturer offers these panels in 6’ & 8’. Especially more important because 3.3.D.3 is calling out post depth 8’ & 18” diameter! A: Width of panels, 6' or 8' is left up to the contractor. 8' would be more practical for our purposes.

• 5.) Q: Why is there a Spec. 323113? Is there an alternate for a permanent vinyl coated chain link fence in lieu of the ornamental aluminum? If so, there’s also no permanent fence details. A: Spec 323113 is not relevant.

• 6.) Q: For the ornamental security fence. The foundations called for are gigantic vs a typical foundation, probably uses 5X as much concrete & labor. Our equipment can not dig to that depth either, so I’d have to sub out. Any consideration to a more normal sized foundation? 4’ deep X 12” diameter? A: The Echelon II fence matches the Visitor’s Center fence. Their requirements call for 8’ deep as shown in the attached product data. There is a possibility for a shallower foundation with closer (6’) post spacing as opposed to the 8’. Still less concrete overall at 8’ spacing though.

Offerors can utilize the basis of design product or an equivalent product with less stringent foundation requirements would also be acceptable, as long as the foundations are at least down below frost depth of 5’ and meet supplier requirements.