This is a set of construction documents issued for bid by the Massachusetts Department of Transportation (MassDOT) for cooling tower replacements at Haymarket Center located at 136 Blackstone Street, Boston, MA 02109. The project, identified as Federal Aid Project No. 616454-134457, involves the full replacement of existing corroded galvanized steel cooling towers with new stainless steel cooling towers of equivalent capacity, provisions for a new cooling system for the mechanical room penthouse, installation of an exhaust ventilation system for the adjacent generator room, and replacement of roof drains below the cooling towers. The construction documents were issued for bid on June 15, 2026, and include architectural, mechanical, plumbing, and electrical drawings prepared by Austin Architects LLC, C.A. Crowley Engineering, Inc., and Art Engineering Corporation. The project is classified as an Alterations - Level 2 per the 2021 International Existing Building Code and must comply with applicable Massachusetts building codes, energy conservation codes, and accessibility regulations. No changes to occupancy, building height, area, or existing sprinkler and fire alarm systems are anticipated.
The project scope includes the installation of two new stainless steel cooling towers (CT-1 and CT-2) with a capacity of 118 CFM and 60 MBH cooling at 95°F wet bulb and 85°F entering water temperature, a new ceiling-mounted air handling unit (AHU-1) with 1,800 CFM capacity, and a new exhaust fan (EF-1) with 1,560 CFM capacity for the generator room. New electrical equipment includes NEMA 4X stainless steel fused disconnect switches for the cooling towers, new GFCI receptacles, and safety disconnect snap switches for the air handling unit, exhaust fan, and motorized damper. Existing condensate water piping, chilled water piping, makeup water piping, and control systems are to remain and be reconnected to the new equipment. The contractor is responsible for equipment location coordination with manufacturer specifications, field verification of existing conditions, and system startup and commissioning to confirm proper operation with existing control sequences.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Boston-A-2.pdf | ||
| 616454-134457 CDSP inclusive.pdf | ||
| MassDOT Haymarket Cooling Towers_PreBid_Sign-in Log_260721.pdf | ||
| BOSTON-A-1.pdf | ||
| Boston-A-3.pdf | ||
| Boston- 616454 - FINAL Sub Bid Results.pdf | ||
| How to submit questions in COMMBUYS.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATE
MA
FED. AID PROJ. NO.
SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO. 616454-134457
COVER SHEET
CONSTRUCTION DOCUMENTS
ISSUED FOR BID
15 JUNE 2026
MASSACHUSETTS DEPARTMENT OF TRANSPORTATION
BOSTON - COOLING TOWER REPLACEMENTS
AT HAYMARKET CENTER
Architect
AUSTIN ARCHITECTS LLC
219 Concord Avenue Cambridge, MA 02138
Mechanical & Plumbing Engineer
C.A. CROWLEY ENGINEERING, INC.
645 County Street, Suite 6 Taunton, MA 02780
136 Blackstone Street Boston, MA 02109
DRAWING LIST
GENERAL
G000 COVER SHEET
G001 SYMBOLS AND ABBREVIATIONS
G002 CODE SUMMARY AND LIFE SAFETY PLANS
ARCHITECTURAL
A101 PARTIAL PLANS AND DETAILS
PLUMBING
P101 PLUMBING NEW WORK PLAN
PD101 PLUMBING DEMO WORK
MECHANICAL
M000 HVAC LEGEND, NOTES, DETAILS AND SCHEDULES
M101 HVAC MECHANICAL ROOM - NEW WORK
MD101 HVAC MECHANICAL ROOM - DEMO
ELECTRICAL
E001 ELECTRICAL LEGEND AND NOTES
E002 ELECTRICAL DETAILS
E101 LEVEL 5 MECHANICAL ROOM PLAN - ELECTRICAL DEMOLITION
E102 LEVEL 5 MECHANICAL ROOM PLAN - PROPOSED ELECTRICAL
APPROXIMATE LOCATION
OF COOLING TOWERS
Electrical Engineer
ART ENGINEERING CORPORATION
38 Front Street, Floor 3 Worcester, MA 01608
N
X#
A5--
A---
101'-0"
9'-6" AFF
A3--
A3--
A3--
A
#A
ARCHITECTURAL STANDARD SYMBOLSABBREVIATIONS
HATCH PATTERNS / MATERIAL SYMBOLS
REF. DWG
DETAIL ON
REF. DWG
Resilient Sheet FlooringRSF
Rubber BaseRB
RequiredREQD
West, Wide, WidthW
Welded Wire FabricWWF
WeightWT
Water ClosetWC
GA Gage, Gauge
GALV Galvanized
GL Glass, Glazing
GMU Glass Masonry Unit d Penny Perpendicular
WIN Window
WO Without
W/ With
A/C Air Conditioning
ALT Alternate
AL/ALUM Aluminum
AB Anchor Bolt
ALRM Alarm
ANOD Anodized
APPROX Approximate
ARCH Architect (ural)
AUTO Automatic
AmountAMT
ADD Addendum
ADH Adhesive
ADJ Adjacent
ADJT Adjustable
AGG Aggregate
VERT Vertical
VEST Vestibule
VP Veneer Plaster
VCT Vinyl Composition Tile
Anchor, AnchorageANC
ABV Above
AFF Above Finished Floor
AP Access Panel
ACOUS Acoustical
ACT Acoustical Tile
Angle
Centerline ChannelC
Acoustic Wall PanelAWP
CAB Cabinet
CUH Cabinet Unit Heater
CPT Carpet (ed)
CB Cement Board
CLG Ceiling
CEM Cement
CTR Center
CT Ceramic Tile
CO Cleanout
DEPT Department
DTL Detail
DIAM Diameter
DIM Dimension
DW Dishwasher
Depress (ed, ion)DEPR
DPR Dispenser
DISP Disposal
DR Door
DO Door Opening
DBL Double
EXH Exhaust
EXST Existing
EXP Expansion, Exposed
EJT Expansion Joint
EXT Exterior
EXTD Extruded
ExposedEXP
ELEV Elevator
EMER Emergency
ENC Enclose (ure)
EQ Equal
EQP Equipment
Entry MatEM
FAB Fabricated
FOC Face of Concrete
FOF Face of Finish
FOM Face of Masonry
FIN Finish (ed)
FF Finished Floor
FA Fire Alarm
FE Fire Extinguisher
FEC Fire Extinguisher Cabinet
FHC Fire Hose Cabinet
Fiber BoardFB
FD Floor Drain
FLUOR Fluorescent
FTG Footing
FLR Floor (ing)
FDN Foundation
FS Full Size
FUR Furred (ing)
FrameFR
GD Grade, Grading
GT Grout
GWB Gypsum Wallboard
GrilleGR
HPT High Point
HC Hollow Core
HM Hollow Metal
HB Hose Bibb
HCP/HDCP Handicapped
HDB Hardboard
HDW Hardware
HVAC Heating/Ventilating/ Air Conditioning
HT Height
High PerformanceHP
LTWT Light Weight
LVR Louver
LAM Laminate (d)
LAV Lavatory
LCC Lead-coated Copper
LH Left Hand
LT Light
MACH Machine
MH Manhole
MFR Manufacture (er)
MAS Masonry
MO Masonry Opening
MIN Minimum
MISC Miscellaneous
MOD Modular
MR Moisture Resistant
MLDG Molding, Moulding
PLAM Plastic Laminate
PWD Plywood
PT Paint (ed)
PVC Polyvinyl Chloride
PBD Particleboard
PTN Partition
PVMT Pavement
PERF Perforate (d)
PLS Plaster
PLN Plan
PR Pair
PNL Panel
RD Roof Drain
RM Room
RO Rough Opening
SCH Schedule
SNT Sealant
SEC Section
RAD Radius
RWL Rainwater Leader
REF Reference
PL PlateRound, Diameter
Reflected Ceiling PlanRCP
SHT Sheet
SM Sheet Metal
SH Shelf, Shelving
SHWR Shower
STD Standard
STA Station
STL Steel
STO Storage
STR Structur (e, al)
SUSP Suspended
Verify In FieldVIF
Americans w/ Disabilities ActADA
BSMT Basement
BM Beam
BRG Bearing
BEL Below
BTWN Between
CMU Concrete Masonry Unit
CONST Construction
CONT Continuous, Continue (d)
CONTR Contractor
CJT Control Joint
CLR Clear (ance)
CLO Closet
COL Column
COMP Compress (ed),(ion),(ible)
CONC Concrete
HorizontalHORZ
T Tread
TYP Typical
UL Underwriters Laboratory
Unless Otherwise NotedUON
AVG Average
BIT Bituminous
BLK Block
BLKG Blocking
BD Board
BOT Bottom
BKT Bracket
BRK Brick
BLDG Building
BUR Built-Up Roofing
CG Corner Guard
CORR Corridor
CRS Course
DA Double Acting
DN Down
DWR Drawer
DWG Drawing
DF
EachEA
Drinking Fountain
E East
ELEC Electric (al)
EWC Electric Water Cooler
EL Elevation
FPRF Fireproof
FIXT Fixture
FR Fire Rating
HR Hour
IN Inch
INCL Include (d),(ing)
ID Inside Diameter
INSUL Insulate (d),(ion)
INT Interior
INV Invert
JAN Janitor
JT Joint
J Joist
KIT Kitchen
MTL Material (s)
MAX Maximum
MECH Mechanical
MC Medicine Cabinet
MET Metal
MTD Mounted
NOM Nominal
NPS Nominal Pipe Size
N North
NA Not Applicable
NIC Not In Contract
NTS Not To Scale
NO Number
OC On Center (s)
OPNG Opening
OPP Opposite
OPH Opposite Hand
OZ Ounce
OD Outside Diameter
OA Overall
OH Overhead
PSF Pounds per Square Foot
PSI Pounds per Square Inch
PROP Proposed
QTY Quantity
QT Quarry Tile
RA Return Air
REV Revision
RH Right Hand
R Riser
SIM Similar
SOG Slab On Grade
STC Sound Transmission Class
S South
SPEC Specification (s)
SQ Square
SS Solid Surface
ST Stair
TKBD Tackboard
TEL Telephone
TEMP Temporary
THK Thick (ness)
T&G Tongue and Groove
T&B Top and Bottom
TC Top of Concrete
TF Top of Footing
TJ Top of Joist
TSL Top of Slab
TST Top of Steel
TW Top of Wall
FOOT Foot
Vinyl BaseVB
JC Janitor Closet
TP Toilet Partition
Solid PlasticSLD PLST
Cementitious Wall BaordCWB
± Plus / Minus
ØDegree (s)°
DemolishedDEM'D
RESIST Resistant
PTW Pressure Treated Wood
WD Wood
DOOR NUMBER
EQUIPMENT TYPE
1- HOUR RATED PARTITION
GYPSUM WALLBOARD
PLASTER ON LATH
PLYWOOD
FIRESAFING
BATT INSULATION
INSULATION
RIGID INSULATION
FIREPROOFING
CONCRETE
PRECAST CONCRETE
CONCRETE MASONRY UNIT
BRICK
CUT STONE
ALUMINUM
PREMOULDED FILLER
ACOUSTICAL TILE
TERRAZZO
RESILIENT FLOORING
CARPET
QUARRY TILE
CERAMIC TILE
GRAVEL
EARTH
WOOD (ROUGH, BLOCKING)
WOOD (ROUGH, CONT)
WOOD (FINISH, SECTION)
STEEL
PLASTIC LAMINATE
NEW CONSTRUCTION
TO BE DEMOLISHED
EXISTING CONSTRUCTION TO REMAIN
2- HOUR RATED PARTITION
COLUMN REFERENCE
NEW DOOR
EXISTING DOOR TO REMAIN, U.O.N.
DETAIL REFERENCE
WALL SECTION
BUILDING SECTION
PARTITION TYPE
GLAZING TYPE
WINDOW TYPE
KEYNOTE REFERENCE
ELEVATION REFERENCE (SECTION)
ELEVATION REFERENCE (PLAN)
ROOM NAME / NUMBER / AREA
INTERIOR ELEVATION REFERENCE
EXTERIOR ELEVATION REFERENCE
LOUVER TYPE
(REF KEY SYMBOLS ON PLAN DWGS)
THERMOSTAT, ELEC OUTLET, SWITCH
A3--
A: xxx SF
ROOM
EXPANSION JOINT
AESS Architecturally Exposed Structural Steel
AEMM Architecturally Exposed Misc. Metal
Level
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number:
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Sheet of
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138
Tel. 617-441-8500
MA -
1/8" = 1'-0"
SYMBOLS AND
ABBREVIATIONS
G001
June 15, 2026 - BID SET
COOLING TOWER
REPLACEMENTS AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
616454-134457
Author
Checker
0856.35
SYMBOLS AND ABBREVIATIONS
616454-134457
No. Description Date
MECHANICAL ROOM
GENERATOR ROOM
STAIR 4
5ST-4
ROOF MECHANICAL
ELEVATOR LOBBY
DN
C
B.5
B.2
B
C.1
432 4.53.31.1
EXISTING FIXED LADDER UP TO
ROOF OVER MECHANICAL ROOM
EXIT 1
EXIT 2
COOLING TOWERS
M A X . O
V E R A
LL D
IA
G
O N A L
O F R
O O
M
= 80'-5"EXIT ACCESS
SEPARATION DISTANCE = 65'-9"
C C
B.5
B.2
B
C.1 C.1
D D
C.7
F
F
G
E
6.5
6.5
7.3
4.53.31.1
EXISTING FIXED LADDER DOWN TO COOLING TOWERS
EXISTING FIXED LADDER UP TO ROOF ABOVE 6TH FLOOR
DN
EGRESS ROUTE ON ROOF TO STAIRWELL REENTRY
OPEN TO BELOW
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number:
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Sheet of
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138
Tel. 617-441-8500
MA -
1/16" = 1'-0"
CODE SUMMARY AND
LIFE SAFETY PLANS
G002
June 15, 2026 - BID SET
COOLING TOWER
REPLACEMENTS AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
616454-134457
Author
Checker
0856.35
CODE SUMMARY AND LIFE SAFETY PLANS
616454-134457
No. Description Date
CODE SUMMARY
PROPOSED WORK IS TO OCCUR AT THE COOLING TOWERS NEXT TO THE FIFTH FLOOR MECHANICAL ROOM OVER THE PARKING GARAGE AT HAYMARKET CENTER IN BOSTON, MA. THE SCOPE OF WORK INCLUDES THE
FOLLOWING:
• FULL REPLACEMENT OF THE EXISTING CORRODED GALVANIZED STEEL COOLING TOWERS WITH NEW
STAINLESS STEEL COOLING TOWERS OF THE SAME CAPACITY.
• PROVISIONS FOR NEW COOLING SYSTEM FOR THE MECHANICAL ROOM PENTHOUSE.
• EXHAUST VENTILATION SYSTEM FOR THE GENERATOR ROOM ADJACENT TO THE COOLING TOWERS.
• REPLACEMENT OF ROOF DRAINS BELOW THE COOLING TOWERS.
THERE IS NO CHANGE IN OCCUPANCY
APPLICABLE CODES:
• 780 CMR - MASSACHUSETTS STATE BUILDING CODE, 10TH EDITION (AMENDMENTS TO IBC):
• 2021 INTERNATIONAL BUILDING CODE
• 2015 INTERNATIONAL EXISTING BUILDING CODE
• 225 CMR 23 COMMERCIAL STRETCH CODE, MA AMENDMENTS TO:
• 2021 INTERNATIONAL ENERGY CONSERVATION CODE
• 2021 INTERNATIONAL MECHANICAL CODE
• 248 CMR - MA UNIFORM STATE PLUMBING CODE (12/08/2023)
• 527 CMR 12 - MA ELECTRICAL CODE (BASED ON NFPA 70 NATIONAL ELECTRICAL CODE)
• 527 CMR 1 - MA FIRE PREVENTION REGULATIONS (BASED ON 2021 NFPA 1)
• 521 CMR - MASSACHUSETTS ARCHITECTURAL ACCESS BOARD REGULATIONS (01/27/2006)
• THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) (09/15/2010)
• NFPA STANDARDS
COMPLIANCE METHOD:
WORK AREA COMPLIANCE METHOD (CHAPTERS 7-8 OF 2021 IEBC)
CLASSIFICATION OF WORK: ALTERATIONS - LEVEL 2 (PER 2021 IEBC SECTION 504)
801.1 THE PROJECT CONSIST OF THE REPLACEMENT OR UPGRADE OF EXISTING MECHANICAL SYSTEMS.
THE PROJECT SHALL COMPLY WITH CHAPTER 8 OF THE IEBC AS APPLICABLE.
801.2 LEVEL 1 COMPLIANCE: IN ADDITION TO CHAPTER 8, THE SCOPE OF WORJ SHALL COMPLY WITH
CHAPTER 7 OF THE IEBC AS WELL.
801.3 SYSTEM INSTALLATIONS: LEVEL 2 ALTERATIONS ARE LIMITED TO MECHANICAL SYSTEMS, REQUIREMENTS RELATED TO WORK AREA ARE NOT APPLICABLE.
801.4 COMPLIANCE: ALL NEW ELEMENTS WILL BE COMPLIANT WITH THE IBC, EXCEPT FOR THE
EXCEPTIONS NOTED IN THIS SECTION.
CONSTRUCTION TYPE:
EXISTING: TYPE IB REDUCED TO IIA BASED ON 780 CMR 602.1.4.1 (5TH ED.)
PROVIDED: NO CHANGE TO EXISTING
AUTOMATIC SPRINKLER SYSTEM:
REQUIRED: YES, EXISTING TO REMAIN
FIRE ALARM NOTIFICATION SYSTEM:
REQUIRED: YES, EXISTING TO REMAIN
BUILDING HEIGHT AND AREA:
NO CHANGE TO EXISTING WITH THIS PROJECT
FIRE RESISTANCE RATING REQUIREMENTS:
EXISTING RATINGS BY FLOOR FOR PARCEL 7 WEST ARE PER CA/T PROJECT RECORD DAWING C15A3-A-201.
MINIMUM FIRE RATINGS REQUIRED:
A. FIRST FLOOR AND ALL STRUCTURES BELOW GRADE - NO WORK THIS PROJECT
B. SECOND FLOOR (INCLUDING SUPPORTING COLUMNS AT FIRST FLOOR) - NO WORK THIS PROJECT
C. THIRD FLOOR - NO WORK THIS PROJECT
D. FOURTH FLOOR / ROOF - NO WORK THIS PROJECT
E. FIFTH FLOOR / ROOF
E.1 2-HR FLOOR CEILING ASSEMBLY AND BEAMS
F. ROOF
F.1 1-1/2 HR TYPICAL ROOF-CEILING ASSEMBLY AND ROOF BEAMS
OCCUPANCY GROUP:
USE GROUP S-2, STORAGE LOW-HAZARD (OPEN PARKING STRUCTURE)
MEANS OF EGRESS - OCCUPANT LOAD FACTORS:
MECHANICAL/STORAGE = 300 SF GROSS PER OCCUPANT
OCCUPANT LOAD:
3288 GSF / 300 GSF PER OCC = 11 OCCUPANTS
MINIMUM NUMBER OF EXITS:
2 REQUIRED, 2 PROVIDED (NO CHANGE), REFER TO LIFE SAFETY PLAN FOR EGRESS ROUTES
PER 780 CMR 1006.2.2.1: TWO EXIT ACCESS DOORWAYS ARE REQUIRED IN BOILER, INCINERATOR AND FURNACE ROOMS WHERE THE AREA IS OVER 500 SF AND ANY FUEL-FIRED EQUIPMENT EXCEEDS 400,000 BTU INPUT CAPACITY. WHERE TWO EXIT ACCESS DOORWAYS ARE REQUIRED, ONE IS PERMITTED TO BE A FIXED LADDER OR AN ALTERNATING TREAD DEVICE. EXIT ACCESS DOORWAYS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE EQUAL TO ONE-HALF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL
DIMENSION OF THE ROOM.
MAX. OVERALL DIAGONAL DISTANCE OF MECHANICAL ROOM = 80'-5"
EXIT ACCESS DOORWAYS SEPARATION DISTANCE = 65'-9" COMPLIES
ACCESSIBILITY:
MASSACHUSETTS ARCHITECTURAL ACCESS BOARD (521 CMR) RULES AND REGULATIONS APPLY TO ALL AREAS ACCESSED BY THE PUBLIC IN COMMERCIAL BUILDINGS. EXISTING ACCESSIBLE ROUTES ARE PROVIDED TO THE FOLLOWING ACCESSIBLE ELEMENTS: PARKING, PUBLIC ENTRANCE, WAITING AREAS, PUBLIC RESTROOMS. NO CHANGE.
ENERGY CONSERVATION (2021 IECC):
IEBC 809.1 MINIMUM REQUIREMENTS: THE ALTERATIONS SHALL CONFORM TO THE ENERGY REQUIREMENTS
OF THE IECC AS THEY RELATE TO NEW CONSTRUCTION.
C501.2 COMPLIANCE PATHWAY: ALTERATIONS TO EXISTING BUILDINGS SHALL COMPLY WITH SECTION
C503 OF THE IECC.
C503 ALTERATIONS: REQUIRES COMPLIANCE WITH SECTION C503, C402, C403, C404 AND C405.
ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTRE IS NO LESS
CONFORMING TO THE PROVISIONS OF THE IECC.
C503.3 HEATING AND COOLING SYSTEMS: NEW COOLING AND DUCT SYSTEMS SHALL COMPLY WITH
SECTION C403 AND C408.
1/16" = 1'-0"
FIFTH FLOOR MECHANICAL RM LIFE SAFETY PLAN
1/16" = 1'-0"
SIXTH FLOOR / ROOF LIFE SAFETY PLAN
GE-02GE-01
GS-02
DN
UP
T Y
P
TYP
10' - 0"
HATCHED AREA INDICATES EXTENT OF
CEMENT PLASTER CEILING TO BE
REMOVED AND REPLACED FOR
REPLACEMENT OF ROOF DRAINS AND
HORIZONTAL PIPING RELATED SCOPE,
REFER TO PLUMBING DRAWINGS FOR
PLUMBING SCOPE BY GC
TYPICAL JOINTS IN CEMENT PLASTER
CEILING TO BE MAINTAINED
A101
TYP
ACCESS PANELS TO BE PROVIDED
BELOW EACH ROOF/FLOOR DRAIN AS
REQUIRED
PAINT CEMENT PLASTER CEILING TO
MATCH EXISTING ADJACENT COLOR
EXISTING CEMENT
PLASTER CEILING TO
REMAIN
3 3.3 42
B
B.2
B.5
C
10" VIF
NEW SEALANT WITH BACKER ROD
NEW CEMENT PLASTER ON METAL
LATH, REFER TO SECTION 092400
EXISTING RIGID INSULATION,
REMOVE AND REINSTALL,
PROVIDE NEW TO MATCH
EXISTING WHERE MISSING
AND/OR DAMAGED
EXISTING TO REMAIN SS CAVITY
CLOSURE TRIM
EXISTING STEEL STRUCTURE
W/ SPRAY FIRE PROOFING,
DO NOT DAMAGE FIRE
PROOFING
NEW J-BEAD, TYP
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number:
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Sheet of
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138
Tel. 617-441-8500
MA -
As indicated
PARTIAL PLANS AND
DETAILS
A101
June 15, 2026 - BID SET
COOLING TOWER
REPLACEMENTS AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
616454-134457
Author
Checker
0856.35
PARTIAL PLANS AND DETAILS
616454-134457
No. Description Date
1/8" = 1'-0"
LEVEL 4 REFLECTED CEILING PLAN (OVER COVERED PARKING AREA)
3" = 1'-0"
CEMENT PLASTER DETAIL AT EDGE, TYP
4" RL
4" R L
4" R L
CO
CO
4" 4"
EXISTING TO REMAIN
4" RAIN LEADER
NEW 4" RAIN LEADER
CONNECT EXISTING
RAIN LEADER
NEW 4"RL UP
TO ROOF DRAIN
NEW 4"RL UP
TO ROOF DRAIN
NEW 4"RL UP
TO ROOF DRAIN
4" R L
1/8" / 1'-0"
EXISTING TO REMAIN
4" RAIN LEADER
4" RD
WATTS FD-200-L
4" RD
WATTS FD-200-L
4" RD
WATTS FD-200-L
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number: 616454-134457
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138 Tel. 617-441-8500
MA -
N
616454-134457
1/8" = 1'-0"
PLUMBING NEW WORK
P101
15 JUNE, 2026 - BID SET
COOLING TOWER
REPLACEMENT AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
RLA
RCV
0856.35
PLUMBING NEW WORK
1/8" = 1'-0"1 PLUMBING - MECHANICAL ROOM PART PLAN - NEW WORK
1/8" = 1'-0"2 PLUMBING - ROOF PART PLAN - NEW WORK
4"
4"
EXISTING TO REMAIN
4" RAIN LEADER
EXISTING TO BE REMOVED
RAIN LEADER
DISCONNECT AND CAP EXISTING
PIPING FOR FUTURE CONNECTION
EXISTING TO BE REMOVE
4"RL UP TO ROOF DRAIN
EXISTING TO BE REMOVE
4"RL UP TO ROOF DRAIN
EXISTING TO BE REMOVE
4"RL UP TO ROOF DRAIN
EXISTING TO REMAIN
4" RAIN LEADER
EXISTING TO BE REMOVE
ROOF DRAIN
EXISTING TO BE REMOVE
ROOF DRAIN
EXISTING TO BE REMOVE
ROOF DRAIN
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number: 616454-134457
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138 Tel. 617-441-8500
MA -
N
616454-134457
1/8" = 1'-0"
PLUMBING DEMO WORK
PD101
15 JUNE, 2026 - BID SET
COOLING TOWER
REPLACEMENT AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
RLA
RCV
0856.35
PLUMBING DEMO WORK
1/8" = 1'-0"1 PLUMBING - MECHANICAL ROOM PART PLAN - DEMO
1/8" = 1'-0"2 PLUMBING - ROOF PART PLAN - DEMO
HVAC LEGEND
CT
AHU
EF
COOLING TOWER
AIR HANDLING UNIT
EXHUAST FAN
CHWS&R CHILLED WATER SUPPLY AND RETURN
AFF ABOVE FINISHED FLOOR
HP HORSE POWER
DN DOWN
HVAC HEATING, VENTILATING & AIR CONDITIONING
DOV DRAIN-OFF VALVE
CFM CUBIC FEET PER MINUTE
EA EXHAUST AIR
OA OUTDOOR AIR
SA SUPPLY AIR
RA RETURN AIR
EC ELECTRICAL CONTRACTOR
GC GENERAL CONTRACTOR
PC PLUMBING CONTRACTOR
BFP BACKFLOW PREVENTER
CD CONDENSATE DRAIN
ESP EXTERNAL STATIC PRESSURE
TYP. TYPICAL
ROUND AIR DUCT UP
ROUND AIR DUCT DOWN
SUPPLY AIR DUCT UP
SUPPLY AIR DUCT DOWN
RETURN/EXHAUST AIR DUCT UP
RETURN/EXHAUST AIR DUCT DOWN
MOTORIZED DAMPER
MD
CONDENSATE WATER SUPPLY
CONDENSATE WATER RETURN
CONDENSATE DRAIN
CHILLED WATER SUPPLY
CHILLED WATER RETURN
MAKE UP WATER PIPE
THERMOSTAT-ELECTRICT
MW
CHWR
CHWS
CD
CNR
CNS PIPE UP
PIPE DOWN
PIPE TEE DROP
PIPE STUB UP W/FLOW ARROW
PIPE ANCHOR
PIPE GUIDE
GATE VALVE
STRAINER
CONTROL VALVE
DRAIN-OFF VALVE W/UNION
DOV
BUTTERFLY VALVE
GLOBE VALVE
BALL VALVE
FLEXIBLE PIPE
THERMOMETER
PRESSURE GAUGE
AUTOMATIC AIR VENT
BACKDRAFT DAMPER
BD
CNS&R CONDENSATE WATER SUPPLY AND RETURN
CONNECT NEW TO EXISTING
1.
2.
3.
4.
ALL EXISTING HVAC SYSTEMS, DUCTWORK, DIFFUSERS, REGISTERS & GRILLES,
PIPING, CONTROLS ETC. SERVING THE BUILDING SHALL REMAIN UNLESS
OTHERWISE NOTED.
CONTRACTOR SHALL RECONNECT PIPING AND CONTROLS TO THE REINSTALLED
EQUIPMENT AND PROVIDE START-UP FOR ALL EQUIPMENT AND CONFIRM
RECONNECTED EQUIPMENT WORKS WITH EXISTING CONTROL SEQUENCE.
CONTRACTOR SHALL LOCATE ALL NEW EQUIPMENT INCLUDING BUT NOT LIMITED TO
THE COOLING TOWERS, FANCOIL UNITS AND EXHAUST FAN ETC. PER MANUFACTURER'S
INSTRUCTIONS MAINTAINING RECOMMENDED CLEARANCES.
CONTRACTOR SHALL COORDINATE THE EXACT LOCATIONS OF ALL EQUIPMENT,
DUCTWORK, PIPING AND ASSOCIATED ACCESSORIES WITH EXISTING
CONDITIONS IN THE FIELD. DRAWINGS ARE DIAGRAMMATIC AND INDICATE
APPROXIMATE LOCATIONS OF THE APPARATUS. ANY DISCREPANCIES IN THE
FIELD SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER
FOR CLARIFICATION.
GENERAL NOTES
1.
2.
KEYED NOTES:
NEW AHU SHALL BE CEILING MOUNTED. PROVIDE NEW CHWS&R PIPING TO CONNECT TO EXISTING PIPING AS SHOWN.
PROVIDE OFFSETS AND FITTINGS AS REQUIRED FOR CONNECTION. ROUTE AHU CD PIPING TO FLOOR DRAIN.
MOUNT COOLING TOWER ON THE EXISTING STEEL DUNNAGE WITH VIBRATION ISOLATION. CONTRACTOR TO COORDINATE SUPPORTING EQUIPMENT IN ACCORDANCE WITH COOLING TOWER MANUFACTURE REQUIREMENTS(TYP.2).
MODEL CFM O.A.
SUPPLY FAN
HP ESP MBH
COOLING
V PH HZ
ELECTRICAL
LBS
WEIGHT
REMARKS
NO.
ITEM
AHU-1 BCHE054 1800 0 1.0 - 54 115 1 60 130 -
BASED ON TRANE
AIR HANDLING UNIT SCHEDULE
SERVICE
MECHANICAL ROOM
BASED ON MARLEY STRUCTURE AND CASING SHALL BE SS301L STAINLESS STEEL.
PROVIDE INTERNAL HEATERS ON ALL FAN MOTORS TO PREVENT INTERNAL CONDENSATION.
PROVIDE GEARBOX WITH 5 YEAR OIL CHANGE INTERVALS.
2 3
HZ
REMARKS
WB (°F)
ELECTRICAL
CFM
EWT (°F)
V PH
LWT (°F)GPMMODELNO.
ITEM FAN MOTORS
HP
EAT
CT-1&2 NC8401NAN1 95 85 78 60118 10 460 3 60
COOLING TOWER SCHEDULE
(FT)
PD
10.43
PROVIDE SINGLE WATER INLET ON ALL TOWERS.
PROVIDE EQUALIZING LINE CONNECTIONS BETWEEN CELLS.
PROVIDE VIBRATION SWITCH ON ALL TOWERS.
PROVIDE ELECTRIC WATER LEVEL CONTROL ON ALL TOWERS.7
4 5 6 7
(LBS)
WEIGHT
8,500
(KW)
BASIN HEATER
AX-36-25-0420-VG-4 IN LINE 19 115/1/60 CONTROLLED BY THERMOSTATGENERATOR ROOMEF-1 1/4900 1560.375
WEIGHT
(LBS) V/PH/HZ
BASED ON GREENHECK
SERVICE
EXHAUST FAN SCHEDULE
ITEM
NO.
MODEL TYPE ESP.
IN.
CFM HP RPM REMARKS
THREADED
SUSPENSION
RODS AS
REQUIRED(TYP.)
VIBRATION
ISOLATOR(TYP.)
STEEL CHANNEL SUPPORT
BY HVAC CONTRACTOR
(TYP.)
EXHAUST AIR DUCT
ROOF SUPPORT
STRUCTURE
FLEXIBLE
CONN.(TYP.)
INLINE FAN
EXHAUST AIR DUCT
NO SCALE
INLINE EXHAUST FAN DETAIL
BD
M
12" DEEP PLENUM
FULL SIZE OF
LOUVER
EXISTING HORIZONTAL
SUPPORT
BEAMS ±42" ON
CENTER
EXISTING METAL PANEL.
PITCH DOWN
TO LOUVER
NOTES:
FURNISH AND INSTALL AN INTAKE AIR DUCT
AS HEREINAFTER SPECIFIED. CUTTING AND
PATCHING SHALL BE BY THIS
CONTRACTOR. LOUVER IS EXISTING.
1.
2. SEQUENCE OF OPERATION: THE EXHAUST FAN
CONTROLS SHALL BE WIRED TO INTERLOCK
WITH THE CONTROL DAMPER LOCATED ON THE
INTAKE LOUVER. THE DAMPER SHALL OPEN AND
THIS WILL ALLOW THE EXHAUST FAN TO
OPERATE ON ACTIVATION OF THE
PROVING SWITCH. THE PROVING SWITCH WILL
DETERMINE IF THE DAMPER IS FULLY OPEN.
SOLDER WATER
TIGHT ALL JOINTS
MOTORIZED DAMPER
EXISTING LOUVER
NO SCALE
INTAKE DUCT INSTALLATION DETAIL
AHU NEW AIR
HANDLING
UNIT
NEW CHILLED
WATER
PIPING
3/4" PVC CONDENSATE
DRAIN TO FLOOR DRAIN
SUPPLY AIRRETURN AIR
NEW VIBRATION
ISOLATOR (TYP.)
NEW THREADED SUSPENSION
RODS AS REQUIRED (TYP.)
NEW COOLING COIL
ROOF SUPPORT
STRUCTURE
NO SCALE
AIR HANDLING SYSTEM - DETAIL
2 POSITION
CONTROL VALVE
BALL VALVE
STRAINER WITH DRAIN VALVE
1/2" MESH GALV. SCREEN1/2" MESH GALV. SCREEN
NEW 1" DRAIN VALVE
EXISTING CHWR
NO SCALE
AHU-1 CHWS&R CONNECTION DETAIL
NEW TEE
TO AHU-1
TO CHILLER
EXISTING CHWS
NEW TEE
TO AHU-1
TO CHILLER
NEW 1" CHWR NEW 1" CHWS
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number: 616454-134457
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138 Tel. 617-441-8500
MA -
616454-134457
As indicated
HVAC LEGEND, NOTES,
DETAILS & SCHEDULES
M000
15 JUNE, 2026 - BID SET
COOLING TOWER
REPLACEMENT AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
YC
MHV
0856.35
HVAC LEGEND, NOTES, DETAILS & SCHEDULES
T T
2 3 3.3 4
B
B.2
B.5
C
C.1
1.1
MECHANICAL ROOM
GENERATOR ROOM
ROOF MECHANICAL
8" CNR
8" CNS
6" C
NS
6" C
NS
6" C
NR
6" C
NR
6" C
NR
6" C
NR
6" C
NR
8" CNR
2" MW
1 1 /4" M W
1 1 /4" M W
EXISTING CONDENSATE
WATER PIPE .
EXISTING
CONDENSATE
WATER PIPE .
EXISTING
CONDENSATE
WATER PIPE .
NEW EQUALIZER
PIPE .
EXISTING MAKE UP
WATER PIPE .
CT
CT
AHU
EF
EXISTING CONDENSATE
WATER PIPE TO CHILLER.
EXISTING CHILLED
WATER PIPE TO CHILLER.
1" C
HW
S
1" CHWR
NEW 1" CHWS&R
CONNECT TO EXISTING
CHWS&R.
CONTROL VALVE
NEW 36"x18" OA DUCT
OPEN ENDED W/WMS.
MOTORIZED DAMPER
INTERLOCKED TO EF-1
EXISTING LOUVER
NEW EA DUCT OPEN
ENDED W/WMS.
BD
EXISTING GENERATOR
TO AHU-1
3" C
HW
R
3" C
HW
S
NEW 1" CD TO
EXISTING FLOOR
DRAIN
MD
EXISTING
COOLING TOWER
STELL DUNNAGE.
EXISTING
COOLING TOWER
STELL DUNNAGE.
RA
SA
HX
8" CNS
8" C
NR
CWP
CWP
CWP
EXISTING
CONDENSATE PUMP
TO EXISTING
CHILLER
EXISTING FREE
COOLING HEAT
EXCHANGER
EXISTING DRY
SPRINKLER PIPING
EXISTING LIGHT
TO BE RELOCATED
6' - 10"
0"
NEW 6" CONDENSATE
WATER PIPE CONECT
TO EXISTING PIPING .
NEW 6"
CONDENSATE
WATER PIPE
CONECT TO
EXISTING PIPING .
0"
6' - 10"
NEW MANUAL
ISOLATION VALVE.
(TYP. FOR 4)
6" C
NS
6" C
NS
NEW DRAIN-OFF
VALVE. (TYP. FOR 3)
TO EF-1
EXISTING LOUVER
EXISTING MOTORIZED
DAMPER FOR GENERATOR
NEW CONTROL
VALVE.
NEW CONTROL
VALVE.
NEW 6" CONDENSATE
WATER PIPE CONECT
TO EXISTING PIPING .
EXISTING AUTOMATIC
BYPASS VALVE TO
REMAIN. (TYP. FOR 2)
NEW ISOLATION
VALVE.
CONNECT
UNDERNEATH UNIT.
(TYP. FOR 2)
NEW EQUALIZER
PIPE UNDER
COOLING TOWER.
NEW EQUALIZER
PIPE UNDER
COOLING TOWER.
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number: 616454-134457
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138 Tel. 617-441-8500
MA -
N
616454-134457
1/4" = 1'-0"
HVAC MECHANICAL
ROOM - NEW WORK
M101
15 JUNE, 2026 - BID SET
COOLING TOWER
REPLACEMENT AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
YC
MHV
0856.35
HVAC MECHANICAL ROOM - NEW WORK
1/4" = 1'-0"1 HVAC - MECHANICAL ROOM PART PLAN - NEW WORK
EXISTING CONDENSATE WATER
PIPE TO REMAIN. (TYP.)
EXISTING
CONDENSATE
WATER PIPE TO
REMAIN. (TYP.)
EXISTING
CONDENSATE
WATER PIPE TO
REMAIN. (TYP.)
EXISTING
EQUALIZER PIPE
TO BE REMOVED.
EXISTING MAKE UP
WATER PIPE TO
REMAIN. (TYP.)
8" CNS
8" CNR
2" MW
8" CNR
6" C
NS
6" C
NR6"
6" C
NS
6"
6" C
NR
6" C
NR
EXISTING
COOLING TOWER
TO BE REMOVED.
EXISTING
COOLING TOWER
TO BE REMOVED.
MECHANICAL ROOM
GENERATOR ROOM
EXISTING GENERATOR
TO REMAIN.
EXISTING
COOLING TOWER
STELL DUNNAGE
TO REMAIN.
EXISTING
COOLING TOWER
STELL DUNNAGE
TO REMAIN.
EXISTING CONDENSATE
WATER PIPE TO CHILLER.
EXISTING
CONDENSATE PUMP
TO REMAIN
TO EXISTING
CHILLER
EXISTING HEAT
EXCHANGER TO
REMAIN
EXISTING
CONDENSATE
WATER PIPE TO
BE REMOVED AND
REINSTALLED .
EXISTING
CONDENSATE
WATER PIPE TO
BE REMOVED AND
REINSTALLED .
EXISTING LOUVER
TO REMAIN
EXISTING LOUVER
TO REMAIN
EXISTING MOTORIZED
DAMPER TO REMAIN
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number: 616454-134457
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138 Tel. 617-441-8500
MA -
N
616454-134457
1/4" = 1'-0"
HVAC MECHANICAL
ROOM - DEMO
MD101
15 JUNE, 2026 - BID SET
COOLING TOWER
REPLACEMENT AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
YC
MHV
0856.35
HVAC MECHANICAL ROOM - DEMO
1/4" = 1'-0"1 HVAC - MECHANICAL ROOM PART PLAN - DEMO
DN
B
B.2
B.5
C
1.1
MECHANICAL ROOM
GENERATOR ROOM
STAIR 4
5ST-4
ROOF MECHANICAL
ELEVATOR LOBBY
PPM
HPM-1
HPM-2
POSB
T-PPM
T-POSB
OSB
ATS-OSB
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
GEP-2
(ETR)
T-PPM
(ETR)
GEP-4
ATS-G
(ETR)
(ETR)
C3
(ETR)
GENERATOR
VFD VFD
CT-1
CT-2
(RP)
(RP)
BH-1
BH-2
(RP)
(RP)
(RP)
(RP)
(ETR) (ETR)
CT-1 CT-2
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number:
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Sheet of
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138
Tel. 617-441-8500
MA -
1/4" = 1'-0"
Level 5 Mechanical Room Plan - Electrical Demolition
E101
June 15, 2026 - BID SET
COOLING TOWER
REPLACEMENTS AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
616454-134457
AC
AC
0856.35
Level 5 Mechanical Room Plan - Electrical Demolition
616454-134457
1/4" = 1'-0"
Level 5 Mechanical Room Plan - Electrical Demolition
KEYED NOTES FOR E101
MAKE SAFE, DISCONNECT, AND REMOVE EXISTING
DISCONNECT SWITCH. INTERCEPT EXISTING WIRING IN A
WEATHERPROOF NEMA 4X STAINLESS STEEL JUNCTION
BOX FOR PROTECTION DURING CONSTRUCTION. PROTECT
AND MAINTAIN EXISTING WIRING FOR RECONNECTION TO
NEW DISCONNECT SWITCH.
MAKE SAFE, DISCONNECT, AND REMOVE EXISTING GFCI
RECEPTACLE. PROTECT EXISTING CIRCUIT FOR
RECONNECTION TO NEW RECEPTACLE.
DN
B
B.2
B.5
1.1
MECHANICAL ROOM
GENERATOR ROOM
STAIR 4
5ST-4
ROOF MECHANICAL
ELEVATOR LOBBY
T
T
M
T
PPM
HPM-1
HPM-2
POSB
T-PPM
T-POSB
OSB
ATS-OSB
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
(ETR)
GEP-2
(ETR)
T-PPM
(ETR)
GEP-4
ATS-G
(ETR)
(ETR)
C3
(ETR)
GENERATOR
CT-1
CT-2
NEMA 4X
HPM-2-8,10,12
NEMA 4X
HPM-2-1,3,5
BH-1
NEMA 4X
HPM-2-20,22,24
BH-2
NEMA 4X
HPM-2-25,27,29
WP/WIC
PPM-4
WP/WIC
PPM-4
VFD VFD
CT-1 CT-2
(ETR) (ETR)
EF-1
PPM-13
AHU-1
PPM-15
PPM-19
Professional Stamp Professional Stamp
Project Name:
MassDOT Project Number:
Project Location:
Project Architect
Drawn By:
Checked By:
AA Project No.:
Scale:
Original Issue Date
Revisions
Plan Name:
Drawing Number:
Sheet of
Project Consultant
STATE FEDERAL AID PROJECT NO. SHEET
NO.
TOTAL
SHEETS
PROJECT FILE NO.
Ten Park Plaza Suite 4160
Boston, MA 02116 857-368-4636 www.mass.gov/massdot
BOSTON
136 BLACKSTONE STREET
219 Concord Avenue Cambridge MA 02138
Tel. 617-441-8500
MA -
1/4" = 1'-0"
Level 5 Mechanical Room Plan - Proposed Electrical
E102
June 15, 2026 - BID SET
COOLING TOWER
REPLACEMENTS AT
HAYMARKET CENTER
136 BLACKSTONE STREET
BOSTON, MA 02109
616454-134457
AC
AC
0856.35
Level 5 Mechanical Room Plan - Proposed Electrical
616454-134457
1/4" = 1'-0"
Level 5 Mechanical Room Plan - Electrical
KEYED NOTES FOR E102
FURNISH AND INSTALL NEW NEMA 4X STAINLESS STEEL
FUSED DISCONNECT SWITCH AT COOLING TOWER.
INTERCEPT AND EXTEND WIRING FROM WEATHER PROOF
JUNCTION BOX TO NEW DISCONNECT SWITCH. CONNECT
TO EXISTING CIRCUITRY, VFD, AND CONTROLS AS SHOWN.
FURNISH AND INSTALL NEW GFCI RECEPTACLES IN PLACE
OF EXISTING. CONNECT TO EXISTING CIRCUITRY AS
SHOWN.
FURNISH AND INSTALL NEW SAFETY DISCONNECT SNAP
SWITCH TO POWER AIR HANDLING UNIT. FURNISH AND
INSTALL 2-12 AWG & 1-12 AWG GND IN 3/4" EMT CONDUIT
TO PANEL PPM.
FURNISH AND INSTALL NEW SAFETY DISCONNECT SNAP
SWITCH TO POWER EXHUAST FAN. FURNISH AND INSTALL
2-12 AWG & 1-12 AWG GND IN 3/4" EMT CONDUIT TO THE
PANEL PPM.
FURNISH AND INSTALL NEW SAFETY DISCONNECT SNAP
SWITCH TO POWER NEW MOTORIZED DAMPER. FURNISH
AND INSTALL 2-12 AWG & 1-12 AWG GND IN 3/4" EMT
CONDUIT TO PANEL PPM.
ELECTRICAL EQUIPMENT SCHEDULE
TAG DESCRIPTION FLA MCA MOCP VOLTAGE POLES
NEMA
RATING
DISC.
SWITCH
DISC.
FUSE PANEL CKT # FEEDER
AHU-1 AIR HANDLING UNIT 16 20 A 20 A 120 V 1 PPM 15 3/4"C, 2#12, #12G
BH-1 BASIN HEATER 9 11.63 A 20 A 480 V 3 NEMA 4X 30A-3P 20AF HPM-2 20,22,24 3/4"C, 3#12, #12G
BH-2 BASIN HEATER 9 11.63 A 20 A 480 V 3 NEMA 4X 30A-3P 20AF HPM-2 25,27,29 3/4"C, 3#12, #12G
CT-1 COOLING TOWER WIRED VIA VFD 14 17.5 A 35 A 480 V 3 NEMA 4X 30A-3P 20AF HPM-2 8,10,12 3/4"C, 3#12, #12G
CT-2 COOLING TOWER WIRED VIA VFD 14 17.5 A 35 A 480 V 3 NEMA 4X 30A-3P 20AF HPM-2 1,3,5 3/4"C, 3#12, #12G
EF-1 EXHAUST FAN 5.8 7.25 A 20 A 120 V 1 PPM 13 3/4"C, 2#12, #12G
No. Description Date
UTILIZE (4) EXISTING 20A-1P SPARE CIRCUIT BREAKERS AS NOTED ABOVE.
Notes:
41 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 42
39 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 40
37 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 38
35 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 36
33 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 34
31 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 32
29 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 30
27 1 20 A -- -- EXISTING SPARE 28
ERU-2/EUH-2 -- -- 20 A 2
1 20 A -- -- EXISTING SPARE 26
23 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 24
21 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 22
19 POWER FOR MOTORIZED DAMPER #12 20 A 1 1 20 A -- -- EXISTING SPARE 20
17 (EXISTING) EF-2 -- -- 20 A 1 1 20 A -- -- EXISTING SPARE 18
15 AHU-1 #12 20 A 1 1 20 A -- -- (EXISTING) MOTORIZED DAMPERS RM551 16
13 EF-1 #12 20 A 1 1 20 A -- -- (EXISTING) EF-3 14
11 (EXISTING) MOTORIZED DAMPERS ERU-2 -- -- 20 A 1 1 20 A -- -- (EXISTING) ERU-2 LIGHTS AND POWER 12
9 EXISTING SPARE -- -- 20 A 1 1 20 A -- -- (EXISTING) ERU-1 LIGHTS AND POWER 10
7 (EXISTING) MOTORIZED DAMPERS ERU-1 -- -- 20 A 1 1 20 A -- -- (EXISTING) RECEPTACLES ERU-1 8
5 (EXISTING) UV LIGHTS ERU-1 -- -- 20 A 1 1 20 A -- -- (EXISTING) CHEMICAL FEED SYSTEM 6
3 (EXISTING) UV LIGHTS ERU-1 -- -- 20 A 1 1 20 A #12 RECEPTACLE 4
1 (EXISTING) UV LIGHTS ERU-2 -- -- 20 A 1 1 20 A -- -- (EXISTING) UNIT HEATERS RM551 2
# Circuit Description Type WIre Trip Poles Poles Trip WIre Type Circuit Description #
Lugs: Standard
Supply From: Trip Size: MLO
Mounting: Surface Phases: 3 Bus Amps: 225
Location: Volts: 120/208 3PH Mains Type: MLO
Panel: Existing - PPM
| MassDOT_Haymarket Cooling Tower Replacement - Sheet - G000 - COVER SHEET |
| MassDOT_Haymarket Cooling Tower Replacement - Sheet - G001 - SYMBOLS AND ABBREVIATIONS |
| MassDOT_Haymarket Cooling Tower Replacement - Sheet - G002 - CODE SUMMARY AND LIFE SAFETY PLANS |
| MassDOT_Haymarket Cooling Tower Replacement - Sheet - A101 - PARTIAL PLANS AND DETAILS |
File details come from the government source that posted it. Updated .