614074 Bid Items List.txt
TXT text file 9 KB Posted
- Solicitation number
- BD-27-1030-0H100-0H002-131777
- Issued by
- Suffolk County, Massachusetts
About this file
This is a bid items list for the Massachusetts Department of Transportation District 6 Standpipe & Fire Safety Inspection, Testing and Repairs project, identified as contract number 614074 with an estimated value of $1.458 million. The scope of work encompasses comprehensive inspection, testing, and repair services across multiple facilities within District 6, including emergency response stations, maintenance facilities, vent buildings, toll facilities, bridges, and tunnel infrastructure. The bid items include 1,100 hours of system repair labor, quarterly inspections at 25 locations (9 occurrences each), semi-annual inspections at 22 locations (5 occurrences each), annual fire pump testing at 15 locations (3 occurrences each), annual inspections at 20 locations (3 occurrences each), and five-year fire safety system tests at 20 locations (1 occurrence each). Additional items include 111 roadway dry standpipe flow tests and hydrostatic tests, four emergency response incidents, and traffic management services including cones, signing, truck-mounted attenuators, temporary illumination, arrow boards, changeable message signs, and reflectorized drums. Electronic proposals are due August 18, 2026 at 2:00 p.m. through www.bidx.com.
All prospective bidders must hold current DCAMM certification in the Fire Protection Sprinkler Systems category, with non-certified bids subject to removal from consideration. Bidders are required to submit a Request Proposal Form (R109) and current DCAMM Certificate of Contractor Eligibility for prequalification approval before accessing proposal documents. Prime and general contractors must additionally provide valid DCAMM Prime/General Contractor Certificates of Eligibility, completed Prime/General Contractor Update Statements, and Document B00521 Forms in compliance with Massachusetts General Law Chapter 149, Section 44D. A proposal guaranty equal to 5% of the bid value is required. Bidders must obtain a Digital ID from www.bidx.com at least 14 days prior to bid opening and possess a valid vendor code issued by MassDOT. The project is subject to prevailing wage rates as determined by the Massachusetts Department of Labor and Workforce Development and must comply with Architectural Access Board rules and Division of Occupational Safety requirements. Award decisions will be made under Massachusetts General Laws Chapter 149, Sections 44A through 44H. No filed sub-bids are required for this solicitation.
Text of this file
PRO_FILENO = 614074,DESCPT = Standpipe & Fire Safety Inspection, Testing and Repairs,Location = DISTRICT 6,DB_CONTRACT = 135792
OFF_QUANT,UNITS,DESCPT1,ITEM_NO
"1100.000","HR","SYSTEM REPAIR-LABOR","100.14"
"9.000","EA","QUARTERLY INSPECTION - EMERGENCY RESPONSE STATION #1","100.201"
"9.000","EA","QUARTERLY INSPECTION - EMERGENCY RESPONSE STATION #2","100.202"
"9.000","EA","QUARTERLY INSPECTION - CENTRAL MAINTENANCE FACILITY","100.203"
"9.000","EA","QUARTERLY INSPECTION - MAINTENANCE FACILITY 10","100.204"
"9.000","EA","QUARTERLY INSPECTION - HIGHWAY OPERATIONS CENTER","100.205"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #1","100.206"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #3","100.207"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #4","100.208"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #10","100.209"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #5","100.210"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #6","100.211"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #7","100.212"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #8","100.213"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #15","100.214"
"9.000","EA","QUARTERLY INSPECTION - AIR INTAKE STRUCTURE","100.215"
"9.000","EA","QUARTERLY INSPECTION - TED WILIAMS TUNNEL IMMERSED TUBE","100.216"
"9.000","EA","QUARTERLY INSPECTION - VENT BUILDING #11","100.217"
"9.000","EA","QUARTERLY INSPECTION - TOLL FACILITY BLDG 1 - RAMP E-T","100.218"
"9.000","EA","QUARTERLY INSPECTION - TOLL FACILITY BLDG 2 - I-90 TOLL PLAZA","100.219" "9.000","EA","QUARTERLY INSPECTION - EMERGENCY RESPONSE STATION #4 / ELEC. STATION #2","100.220"
"9.000","EA","QUARTERLY INSPECTION - ELECTRICAL SUBSTATION #3","100.222"
"9.000","EA","QUARTERLY INSPECTION - 185 KNEELAND BLDG BOSTON","100.226"
"9.000","EA","QUARTERLY INSPECTION - FORE RIVER BRIDGE","100.227"
"9.000","EA","QUARTERLY INSPECTION - CHELSEA BRIDGE","100.228"
"9.000","EA","QUARTERLY INSPECTION - TOBIN ADMIN (TOBIN MF)","100.229"
"9.000","EA","QUARTERLY INSPECTION - INTERCHANGE 14","100.230"
"5.000","EA","SEMI-ANNUAL INSPECTION - EMERGENCY RESPONSE STATION #1","100.231"
"5.000","EA","SEMI-ANNUAL INSPECTION - EMERGENCY RESPONSE STATION #2","100.232"
"5.000","EA","SEMI-ANNUAL INSPECTION - CENTRAL MAINTENANCE FACILITY","100.233"
"5.000","EA","SEMI-ANNUAL INSPECTION - MAINTENANCE FACILITY / ERS 10","100.234"
"5.000","EA","SEMI-ANNUAL INSPECTION -HIGHWAY OPERATIONS CENTER","100.235"
"5.000","EA","SEMI-ANNUAL INSPECTION -VENT BUILDING #1","100.236"
"5.000","EA","SEMI-ANNUAL INSPECTION -VENT BUILDING #3","100.237"
"5.000","EA","SEMI-ANNUAL INSPECTION -VENT BUILDING #4","100.238"
"5.000","EA","SEMI-ANNUAL INSPECTION -VENT BUILDING #5","100.240"
"5.000","EA","SEMI-ANNUAL INSPECTION -VENT BUILDING #6","100.241"
"5.000","EA","SEMI-ANNUAL INSPECTION -VENT BUILDING #7","100.242"
"5.000","EA","SEMI-ANNUAL INSPECTION -VENT BUILDING #8","100.243"
"5.000","EA","SEMI-ANNUAL INSPECTION -VENT BUILDING #15","100.244"
"5.000","EA","SEMI-ANNUAL INSPECTION - AIR INTAKE STRUCTURE","100.245"
"5.000","EA","SEMI-ANNUAL INSPECTION -TED WILLIAMS TUNNEL IMMERSED TUBE","100.246"
"5.000","EA","SEMI-ANNUAL INSPECTION -TOLL FACILITY BLDG 1 - RAMP E-T","100.248"
"5.000","EA","SEMI-ANNUAL INSPECTION - TOLL FACILITY BLDG 2 - I-90 TOLL PLAZA","100.249" "5.000","EA","SEMI-ANNUAL INSPECTION - EMERGENCY RESPONSE STATION #4 / ELEC. STA. #2","100.250"
"5.000","EA","SEMI-ANNUAL INSPECTION - ELECTRICAL SUBSTATION #3","100.252"
"5.000","EA","SEMI-ANNUAL INSPECTION -185 KNEELAND BLDG BOSTON","100.256"
"5.000","EA","SEMI-ANNUAL INSPECTION - MILTON DEPOT FUEL ISLAND","100.257"
"5.000","EA","SEMI-ANNUAL INSPECTION - WESTWOOD DEPOT FUEL ISLAND","100.258"
"5.000","EA","SEMI-ANNUAL INSPECTION -TOBIN ADMIN (TOBIN MF)","100.259"
"5.000","EA","SEMI-ANNUAL INSPECTION - INTERCHANGE 14","100.260"
"5.000","EA","SEMI-ANNUAL INSPECTION - FORE RIVER BRIDGE","100.261"
"5.000","EA","SEMI-ANNUAL INSPECTION - CHELSEA BRIDGE","100.262"
"3.000","EA","ANNUAL FIRE PUMP TESTING - EMERGENCY RESPONSE STATION #1","100.270" "3.000","EA","ANNUAL FIRE PUMP TESTING - EMERGENCY RESPONSE STATION #2","100.271"
"3.000","EA","ANNUAL FIRE PUMP TESTING - CENTRAL MAINTENANCE FACILITY","100.272"
"3.000","EA","ANNUAL FIRE PUMP TESTING - MAINTENANCE FACILITY / ERS 10","100.273"
"3.000","EA","ANNUAL FIRE PUMP TESTING - HIGHWAY OPERATIONS CENTER","100.274"
"3.000","EA","ANNUAL FIRE PUMP TESTING - VENT BUILDING #1","100.275"
"3.000","EA","ANNUAL FIRE PUMP TESTING - VENT BUILDING #3","100.276"
"3.000","EA","ANNUAL FIRE PUMP TESTING -185 KNEELAND BLDG BOSTON","100.277"
"3.000","EA","ANNUAL FIRE PUMP TESTING - VENT BUILDING #5","100.279"
"3.000","EA","ANNUAL FIRE PUMP TESTING - VENT BUILDING #6","100.280"
"3.000","EA","ANNUAL FIRE PUMP TESTING - VENT BUILDING #7","100.281"
"3.000","EA","ANNUAL FIRE PUMP TESTING - VENT BUILDING #8","100.282"
"3.000","EA","ANNUAL FIRE PUMP TESTING - CANA","100.283"
"3.000","EA","ANNUAL FIRE PUMP TESTING - AIR INTAKE STRUCTURE","100.284"
"3.000","EA","ANNUAL FIRE PUMP TESTING -TOLL FACILITY BLDG 1 - RAMP E-T","100.285" "3.000","EA","ANNUAL FIRE PUMP TESTING - TOLL FACILITY BLDG 2 - I-90 TOLL PLAZA","100.286"
"3.000","EA","ANNUAL FIRE PUMP TESTING - FORE RIVER BRIDGE","100.287"
"3.000","EA","ANNUAL FIRE PUMP TESTING - CHELSEA BRIDGE","100.288"
"3.000","EA","ANNUAL INSPECTION - EMERGENCY RESPONSE STATION #1","100.351"
"3.000","EA","ANNUAL INSPECTION - EMERGENCY RESPONSE STATION #2","100.352"
"3.000","EA","ANNUAL INSPECTION - CENTRAL MAINTENANCE FACILITY","100.353"
"3.000","EA","ANNUAL INSPECTION - MAINTENANCE FACILITY / ERS 10","100.354"
"3.000","EA","ANNUAL INSPECTION - HIGHWAY OPERATIONS CENTER","100.355"
"3.000","EA","ANNUAL INSPECTION - VENT BUILDING #1","100.356"
"3.000","EA","ANNUAL INSPECTION - VENT BUILDING #3","100.357"
"3.000","EA","ANNUAL INSPECTION - VENT BUILDING #4","100.358"
"3.000","EA","ANNUAL INSPECTION - VENT BUILDING #5","100.359"
"3.000","EA","ANNUAL INSPECTION - VENT BUILDING #6","100.360"
"3.000","EA","ANNUAL INSPECTION - VENT BUILDING #7","100.361"
"3.000","EA","ANNUAL INSPECTION - VENT BUILDING #8","100.362"
"3.000","EA","ANNUAL INSPECTION - VENT BUILDING #15","100.363"
"3.000","EA","ANNUAL INSPECTION - AIR INTAKE STRUCTURE","100.364"
"3.000","EA","ANNUAL INSPECTION - TED WILLIAMS TUNNEL IMMERSED TUBE","100.365"
"3.000","EA","ANNUAL INSPECTION - TOLL FACILITY BLDG 1 - RAMP E-T","100.366"
"3.000","EA","ANNUAL INSPECTION - TOLL FACILITY BLDG 2 -I-90 TOLL PLAZA","100.367" "3.000","EA","ANNUAL INSPECTION- EMERGENCY RESPONSE STATION #4 / ELEC. STA. #2","100.368"
"3.000","EA","ANNUAL INSPECTION - ELECTRICAL SUBSTATION #3","100.369"
"3.000","EA","ANNUAL INSPECTION - 185 KNEELAND BLDG BOSTON","100.370"
"3.000","EA","ANNUAL INSPECTION - TOBIN ADMIN (TOBIN MF)","100.371"
"3.000","EA","ANNUAL INSPECTION - INTERCHANGE 14","100.372"
"3.000","EA","ANNUAL INSPECTION - FORE RIVER BRIDGE","100.373"
"3.000","EA","ANNUAL INSPECTION - CHEALSEA BRIDGE","100.374"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - EMERGENCY RESPONSE STATION #1","100.451" "1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - EMERGENCY RESPONSE STATION #2","100.452" "1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - CENTRAL MAINTENANCE FACILITY","100.453" "1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - MAINTENANCE FACILITY / ERS 10","100.454" "1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - HIGHWAY OPERATIONS CENTER","100.455"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - VENT BUILDING #1","100.456"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - VENT BUILDING #3","100.457"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - VENT BUILDING #4","100.458"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - VENT BUILDING #5","100.459"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - VENT BUILDING #6","100.460"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - VENT BUILDING #7","100.461"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - VENT BUILDING #8","100.462"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - VENT BUILDING #15","100.463"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - AIR INTAKE STRUCTURE","100.464"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - TED WILLIAMS TUNNEL IMMERSED TUBE","100.465" "1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - TOLL FACILITY BLDG 1 - RAMP E-T","100.466" "1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - TOLL FACILITY BLDG 2 -I-90 TOLL PLAZA","100.467" "1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - EMERGENCY RESPONSE STATION #4 / ELEC. STA. #2","100.468"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST -ELECTRICAL SUBSTATION #3","100.469"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - 185 KNEELAND BLDG BOSTON","100.470"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - TOBIN ADMIN (TOBIN MF)","100.471"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - INTERCHANGE 14","100.472"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - FORE RIVER BRIDGE","100.473"
"1.000","EA","5-YR FIRE SAFETY SYSTEM TEST - CHEALSEA BRIDGE","100.474"
"111.000","EA","ROADWAY DRY STANDPIPE FLOW TEST","100.65"
"111.000","EA","ROADWAY DRY STANDPIPE HYDROSTATIC TEST","100.66"
"4.000","EA","EMERGENCY RESPONSE","748.1"
"10.000","DAY","TRAFFIC CONES FOR TRAFFIC MANAGEMENT","851.1"
"25.000","SF","SAFETY SIGNING FOR TRAFFIC MANAGEMENT","852."
"20.000","DAY","TRUCK MOUNTED ATTENUATOR","853.403"
"10.000","DAY","TEMPORARY ILLUMINATION FOR WORK ZONE","853.8"
"10.000","DAY","ARROW BOARD (TYPE B)","856.060"
"10.000","DAY","PORTABLE CHANGEABLE MESSAGE SIGN","856.12"
"5.000","DAY","REFLECTORIZED DRUM","859."
"10.000","DAY","REFLECTORIZED DRUMS WITH SEQUENTIAL FLASHING WARNING LIGHTS","859.1"