60-79500-25-00264_2. 60-79500-5-00264 Exhibit D Builder RFP Housing Plans.pdf.PDF
PDF 9 MB Posted
- Solicitation number
- 60-79500-25-00264
- Issued by
- New Mexico
About this file
Summary of Representative Housing Plans for New Mexico Home Recovery Program
This document comprises architectural and structural design plans and specifications for three single-family residential housing types (Zuni, Chuska, and Peloncilla models) developed for the State of New Mexico's residential construction services program. The plans include floor plans, roof plans, exterior elevations, electrical layouts, plumbing systems, HVAC designs, and comprehensive construction details for both slab-on-grade (SOG) and pier-and-beam (P&B) foundation options. The reference plan sets establish consistent pricing and cost comparison bases among offerors but are not program-approved construction drawings and will not be used for actual construction. Selected contractors will be required to develop, submit, and obtain approval for their own complete architectural and engineering design sets in accordance with all applicable federal, state, and local requirements, as well as program design and construction standards. The housing units range from approximately 1,077 to 1,478 square feet and must comply with the 2021 International Residential Code, New Mexico Building Code, and certifications for one HUD-approved energy program and one HUD-approved green program.
The specifications establish comprehensive minimum requirements for all materials, construction methods, and installations, including fiber cement siding (James Hardie), 30-year architectural asphalt shingles, vinyl windows with low-E insulation, energy-efficient appliances, and various structural elements dependent on site conditions. All contractors must carry workers compensation insurance, liability insurance, and builder's risk insurance in contractually specified amounts, secure all necessary permits and approvals from local authorities having jurisdiction, conduct special inspections as required by code, and provide one-year warranties on workmanship and materials. The program requires compliance with passive radon protection measures, flood elevation requirements where applicable, accessible design features where mandated, and adherence to all addenda and change orders that take precedence over original construction documents. The contractor assumes responsibility for site security, material storage, temporary utilities, compliance verification, and coordination of all trades to ensure professional workmanship and code-compliant, constructible final designs responsive to program requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXHIBIT D: REPRESENTATIVE
HOUSING PLANS
The reference plan sets are not program-approved construction drawings and shall not be construed as pre-approved designs for permitting or construction. The plans provided with this solicitation are issued solely to establish a consistent basis for pricing and cost comparisons among Offerors. These reference plan sets are intended to illustrate general housing types, approximate scope, and relative complexity only.
Offerors are advised that the reference plan sets will not be used to construct program homes.
Final design and construction documents will be project-specific and may vary based on site conditions, local code requirements, household needs, and program standards.
As part of contract performance, the selected contractor(s) will be required to develop, submit, and obtain approval for their own complete architectural and engineering design sets in accordance with all applicable federal, state, and local requirements, as well as program design and construction standards.
Submission of pricing based on the reference plan sets does not relieve the contractor of responsibility for ensuring that final designs are code-compliant, constructible, and responsive to program requirements.
GN-0.00
GENERAL NOTES
DRAWING LIST
TABLE OF CONTENTS
GN-0.00 GENERAL NOTES
GN-0.10 GENERAL NOTES
GN-0.20 AGEING IN PLACE
A-1.00 FLOOR PLAN - ROOF PLAN
A-2.00 EXTERIOR ELEVATIONS (ELEVATED)
A-2.10 EXTERIOR ELEVATIONS (SLAB ON GRADE)
A-3.00 ELECTRICAL PLAN
A-4.00 PLUMBING PLAN
A-5.00 HVAC PLAN
A-6.00 STANDARD SECTIONS 1 (ELEVATED)
A-6.01 STANDARD SECTIONS 1 (SLAB ON GRADE)
A-6.10 STANDARD SECTIONS 2
A-6.20 STANDARD SECTIONS 3
NM BUILDING CODE, 14.7.3 NMAC, 2021 IBC, AS AMENDED
BUILDING CODES
THIS PROJECT SHALL COMPLY WITH THE:
XX-XXXX-XXX -XXX -XXX -X -X.XX
COBALT PROJ. NO.
PROGRAM FLOOR PLAN STYLE
YEAR
FOUNDATION TYPE
DISCIPLINE
SHEET NO.
EXAMPLE:
19-0000-COH-ACA-SOG-A-1.00
PROGRAM:
NM-FAFR
FOUNDATION TYPES
SOG : SLAB ON GRADE
P&B : PIER & BEAM
DISCIPLINE
C CIVIL AND SITE
A ARCHITECTURAL
F FOUNDATION
S STRUCTURAL
M MECHANICAL
E ELECTRICAL
P PLUMBING
ARCHITECTURAL SYMBOLS
NORTH ARROW
1 DOOR TAG
A WINDOW TAG
LEGEND
EXTERIOR ELEVATION
SYMBOL
X KEY NOTE TAG
FLOOR PLAN STYLES
ZUN ZUNI
CHU CHUSKA
PLN PELONCILLA
STATE OF NEW MEXICO
GENERAL NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR MAKING SURE ALL SPECIAL INSPECTIONS
REQUIRED IN IBC AND IS COMPLETED AND PROVIDE THE LOCAL MUNICIPALITY WITH
THE INSPECTION AGENCY, CONTACT INFORMATION AND SPECIAL INSPECTION
PERFORMED.
2. GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING CONSTRUCTION
ADHERES TO FEMA FLOOD PLAIN, LOCAL MUNICIPALITY, (FFE) FINISHED FLOOR
ELEVATION REQUIREMENTS AND/OR DISASTER RECOVERY CONSTRUCTION
GUIDELINES.
3. GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL LOCAL
MINICIPALITY CODE REQUIREMENTS AND/OR DISASTER RECOVERY CONSTRUCTION
GUIDELINES.
4. CONTRACTOR SHALL UNDERSTAND THAT THE WORK SPECIFIED HEREIN AND
SHOWN ON THE DRAWINGS SHALL BE A FINISHED AND WORKING JOB AS AGREED
UPON IN THE CONSTRUCTION AGREEMENT BETWEEN THE APPLICANT AND THE
CONTRACTOR. ALL WORK SHALL COMPLY WITH CURRENT FEDERAL, STATE, LOCAL
BUILDING CODES/ORDINANCES, AND THE STATE OF NEW MEXICO PROGRAM
REQUIREMENTS. AS WELL AS, CERTIFIED AS ONE HUD APPROVED ENERGY
PROGRAM AND ONE HUD APPROVED GREEN PROGRAM.
5. ADDENDA AND CHANGE ORDERS TO DRAWINGS AND SPECIFICATIONS TAKE
PRECEDENCE OVER THE ORIGINAL CONSTRUCTION DOCUMENTS. SHOULD THERE
BE A CONFLICT BETWEEN ANY OF THE CONSTRUCTION DOCUMENTS, THE MOST
STRINGENT OF THE CONFLICTING REQUIREMENTS WILL APPLY. CONTRACTOR WILL
CONSULT WITH PROGRAM VENDOR WHEN CONFLICTS ARISE.
6. CONTRACTOR IS TO SECURE AND PAY FOR ALL PERMITS AND FILE ALL REQUIRED
DRAWINGS, SPECIFICATIONS AND CERTIFICATIONS WITH THE AUTHORITY HAVING
JURISDICTION.
7. CONTRACTOR TO SECURE AND PAY FOR ALL INSPECTIONS REQUIRED FOR
INDEPENDENT INSPECTION PROCESS WHEN THERE IS NO LOCAL AUTHORITY
HAVING JURISDICTION. LEE CARES WILL REQUIRE A CERTIFICATE OF COMPLETION
WHEN THERE IS NO AHJ BY A LICENSED INDEPENDENT INSPECTOR.
8. WHEN REQUIRED CONTRACTOR SHALL BUILD TO FORTIFIED STANDARDS SET BY
THE CITY AND/OR COUNTY AGENCY HAVING JURISDICTION.
9. CONTRACTOR SHALL PROVIDE AN ACCESSIBLE ROUTE, RAMP, OR WHERE NOT
POSSIBLE, A WHEELCHAIR LIFT MEETING ADA REQUIREMENTS TO PROVIDE
ACCESS TO ONE (1) ACCESSIBLE EXTERIOR DOOR ENTRANCE WHERE REQUIRED
BY THE PROGRAM. IF THE APPLICANT HAS AN APPROVED VERIFICATION OF
DISABILITY FORM AND REQUESTED THE NO STEP ENTRANCE.
10. ALL DIMENSIONS ARE FROM FACE OF STUD UNLESS OTHERWISE NOTED.
11. DO NOT SCALE DRAWING. FOLLOW DIMENSIONS ONLY.
12. WINDOW SIZES INDICATED ON PLANS ARE APPROXIMATE ROUGH OPENING.
13. CONTRACTOR SHALL FIELD VERIFY ALL CABINET DIMENSIONS BEFORE
FABRICATION.
14. ALL GLASS LOCATED WITHIN 18" OF FLOOR, 12" OF A DOOR, OR LOCATED WITHIN
60" OF SHOWERS SHALL BE TEMPERED.
15. THE GENERAL CONTRACTOR MUST COMPLY WITH THE REQUIREMENTS OF THE
LOCAL MUNICIPALITY AND THE OWNER FOR THE USE OF PREMISES, ACCESS TO
THE PROJECT SITE AND TRASH REMOVAL.
16. THE GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COORDINATING
THE WORK OF ALL TRADES, SHALL CHECK ALL DIMENSIONS AND COORDINATE THE
DOCUMENTS WITH CONDITIONS AT THE JOB SITE.
17. THE DOCUMENTS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.
18. THE GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR JOB SITE
SAFETY. DIMENSIONS WHICH MUST BE CONFIRMED AND COORDINATED AT THE
JOB SITE. FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION.
COORDINATING THE WORK OF ALL OTHER TRADES. AND THE SATISFACTORY
PERFORMANCE OF THE SUBCONTRACTORS.
19. WATERLINES RUNNING THROUGH UNCONDITIONED SPACES SHALL BE INSULATED.
20. COORDINATE LOCATION OF UTILITY METERS WITH SITE PLAN AND LOCATE AWAY
FROM PUBLIC VIEW.
21. ALL EXPOSED INSULATION SHALL HAVE A FLAME SPREAD RATING OF LESS THAN 25
AND A SMOKE DENSITY RATING OF LESS THAN 450.
22. PROVIDE COMBUSTION AIR VENTS WITH SCREEN AND BACK DAMPER FOR ANY
APPLIANCE WITH AN OPEN FLAME.
23. ALL BATH AND TOILET AREA WALLS AND CEILINGS SHALL HAVE WATER RESISTANT
GYP. BOARD. RESTROOM WALLS SHALL BE SMOOTH, HARD, AND NONABSORBENT
TO A MIN. HT. OF 48" WITHIN 2'-0" OF A TOILET.
24. ALL WINDOWS AND GLAZING VALUES FOR NFRC RATED U AND SHGC TO MEET
MINIMUM REQUIREMENTS AS STATED PER ICC, CLIMATE ZONE, AND ENERGY
CALCULATION. AS WELL AS, CERTIFIED AS ONE HUD APPROVED ENERGY PROGRAM
AND ONE HUD APPROVED GREEN PROGRAM.
25. ATTIC TO HAVE MINIMUM R-38 INSULATION. CONSULT ENERGY CALCULATION FOR
REQUIRED R-VALUE.
26. NOTE: ALL VALUES ARE PUT FORTH AS A MINIMUM. THE STRICTER VALUE FOUND
AMONG THE ENERGY CALCULATION, GREEN CHECKLIST, AND/OR HVAC
CALCULATION SHALL BE USED.
GENERAL CONDITIONS
1. CONTRACTOR SHALL CARRY WORKERS COMPENSATION INSURANCE, LIABILITY
INSURANCE, AND BUILDER’S RISK INSURANCE, IN THE AMOUNT CONTRACTUALLY
SPECIFIED, ON EACH INDIVIDUAL PROJECT.
2. MATERIAL STANDARDS SHALL CONFORM TO HUD REQUIREMENTS OR AS SPECIFIED
BY PROGRAM PLANS, WHICHEVER IS GREATER.
3. THIS HOME WILL BE SUBJECT TO A MINIMUM OF TWO SEPARATE INSPECTIONS (ONE
AT INSULATION BEFORE DRYWALL AND ONE WHEN HOME IS READY FOR FINAL
BUILDING INSPECTION) BY RATING COMPANY
4. THIS HOME SHALL BE CERTIFIED AS ONE HUD APPROVED ENERGY PROGRAM AND
ONE HUD APPROVED GREEN PROGRAM.
5. CONTRACTOR IS RESPONSIBLE FOR MEETING ALL ENERGY AND GREEN PROGRAM
CERTIFICATIONS AND OTHER PROGRAM REQUIREMENTS.
6. THE ARCHITECTURAL PLANS STATE MINIMUMS AS REQUIRED BY CODE. ANY
VARIATION THAT SURPASSES MINIMUM REQUIREMENTS IS PERMISSIBLE.
7. N/A
8. CONTRACTOR WILL PROVIDE TEMPORARY POWER, WATER, AND PORTABLE TOILET.
SERVICE FOR TEMPORARY WATER, MAINTENANCE AND DELIVERY OF PORTABLE
TOILET UNTIL REMOVAL, AND ALL ASSOCIATED CHARGES FOR SAME.
9. CONTRACTOR IS RESPONSIBLE FOR SECURITY OF SITE AND STORAGE OF
MATERIALS FROM WEATHER, THEFT, VANDALISM, AND THE LIKE. PROGRAM IS NOT
RESPONSIBLE FOR ANY EXPENSES OR COSTS INCURRED AS A RESULT OF THE
AFOREMENTIONED EVENTS.
10. ALL MATERIALS MUST BE IN NEW AND UNUSED CONDITION. REPURPOSING
PREVIOUSLY INSTALLED MATERIALS IS NOT ALLOWABLE.
11. ALL MANUFACTURER INSTALLATION INSTRUCTIONS SHALL BE ADHERED TO.
FASTENERS AND INSTALLATION METHODS USED MUST BE AS PER MANUFACTURER
INSTRUCTIONS.
12. ALL SPECIFICATION SHEETS AND ASSOCIATED WARRANTY DOCUMENTATION
(APPLIANCES, MECHANICAL UTILITIES, HARDWARE, ETC.) WILL BE GIVEN TO THE
APPLICANT NO LATER THAN AT THE TIME OF THE FINAL INSPECTION.
13. FINISHES SHALL BE SELECTED BY THE APPLICANT BEFORE CONSTRUCTION START
OR ITEM INSTALLATION. CONTRACTORS MAY NOT DEVIATE FROM THE SCOPE OF
WORK WITHOUT PRIOR DISCUSSION WITH AND WRITTEN, SIGNED APPROVAL FROM
THE PROGRAM FIRST AND THEN THE APPLICANT. SELECTION DOCUMENT MUST BE
UPLOADED TO SYSTEM OF RECORD.
14. ALL WORK WILL BE PERFORMED IN A PROFESSIONAL AND WORKMANLIKE MANNER
AND IN CONFORMANCE WITH MANUFACTURER REQUIREMENTS. SEAMS, JOINTS,
MITERS, ETC. WILL BE TIGHT AND COSMETICALLY CORRECT. SPLITS, GAPS, CHIPS,
ETC. ARE NOT ALLOWABLE. TRIM-OUTS AND FINISH ELEMENTS SHALL BE OF THE
SAME COLOR AND/OR TYPE. EXAMPLE: WHITE RECEPTACLES WITH WHITE COVER
PLATES, NICKEL DOOR HINGES WITH NICKEL DOORKNOBS.
15. ALL NEW RESIDENTIAL BUILDINGS AND ADDITIONS TO EXISTING RESIDENTIAL
BUILDINGS, CONTRACTOR IS RESPONSIBLE AND SHALL USE PASSIVE RADON
PROTECTION MEASURES. REFERENCE 2021 APPENDIX F NEW MEXICO STANDARD
FOR PASSIVE RADON-RESISTANT NEW RESIDENTIAL BUILDING CONSTRUCTION.
CONCRETE
1. CONSTRUCT FORMS TO THE EXACT SIZES, SHAPES, LINES AND DIMENSIONS
SHOWN, AND AS REQUIRED TO OBTAIN ACCURATE ALIGNMENT, LOCATION AND
GRADES. PROVIDE FOR OPENINGS, BLOCKING, INSERTS AND OTHER FEATURES
REQUIRED FOR THE WORK.
2. THOROUGHLY CLEAN FORMS AND ADJACENT SURFACES TO RECEIVE CONCRETE.
REMOVE CHIPS, WOOD, SAWDUST, DIRT OR OTHER DEBRIS JUST BEFORE
CONCRETE IS TO BE PLACED.
3. REFER TO STRUCTURAL DRAWINGS FOR EXACT SPECIFICATIONS AND COMPLY
WITH THE SPECIFIED CODES AND STANDARDS.
4. CLEAN REINFORCEMENT TO BE FREE FROM LOOSE RUST, MILL SCALE, EARTH, ICE,
AND OTHER MATERIALS THAT REDUCE OR DESTROY BOND WITH THE CONCRETE.
5. ACCURATELY POSITION, SUPPORT AND SECURE REINFORCEMENT AGAINST
DISPLACEMENT BY FORMWORK, CONSTRUCTION, OR CONCRETE PLACEMENT
OPERATIONS. LOCATE AND SUPPORT REINFORCING BY METAL CHAIRS, RUNNERS,
BOLSTERS, SPACERS, AND HANGERS AS REQUIRED.
6. ARRANGE, SPACE, AND ACCURATELY TIE BARS AND BAR SUPPORTS TOGETHER
WITH 16-GAUGE WIRE TO HOLD REINFORCEMENT ACCURATELY IN POSITION
DURING CONCRETE PLACEMENT OPERATIONS.
7. CONCRETE USED FOR BUILDING SLABS SHALL BE 3,000 PSI 28-DAY COMPRESSIVE
STRENGTH WITH A 5 ½ IN. MAXIMUM AND 3 IN. MINIMUM SLUMP. REFER TO
STRUCTURAL DRAWINGS FOR EXACT SPECIFICATIONS AND INSTALLATION
REQUIREMENTS.
8. ALL CONCRETE IS TO BE POURED WHEN THE TEMPERATURE IS AT FORTY DEGREES
FAHRENHEIT (40 F) OR ABOVE AND RISING. IF THE SURFACE TEMPERATURE IS
OVER NINETY DEGREES FAHRENHEIT (90 F) STEPS TO COOL THE SURFACE SUCH
AS WATERING WILL BE TAKEN AS REQUIRED. REFER TO STRUCTURAL DRAWINGS
FOR EXACT SPECIFICATIONS AND ADDITIONAL INSTALLATION REQUIREMENTS.
9. ALL CONCRETE SLAB ON GRADE FOUNDATIONS SHALL BE PLACED
MONOLITHICALLY AND BE A MINIMUM OF 4 INCHES THICK. TOP OF SLAB PLACED ON
GRADE MUST BE A MINIMUM OF 6 INCHES ABOVE SURROUNDING SOIL LEVEL AFTER
FINAL GRADE. REFER TO STRUCTURAL DRAWINGS FOR SPECIFICATIONS.
10. DEPOSIT CONCRETE CONTINUOUSLY OR IN LAYERS OF SUCH THICKNESS THAT NO
CONCRETE WILL BE PLACED ON CONCRETE THAT HAS HARDENED SUFFICIENTLY
TO CAUSE THE FORMATION OF SEAMS OR PLANES OF WEAKNESS WITHIN THE
SECTION. IF A SECTION CANNOT BE PLACED CONTINUOUSLY, PROVIDE
CONSTRUCTION JOINTS.
11. PLACING CONCRETE IN FORMS. DEPOSIT CONCRETE IN FORMS IN HORIZONTAL
LAYERS IN A MANNER TO AVOID INCLINED CONSTRUCTION JOINTS. CONSOLIDATE
ALL CONCRETE PLACED IN FORMS BY MECHANICAL VIBRATING EQUIPMENT
SUPPLEMENTED BY HAND-SPADING, RODDING OR TAMPING. MAINTAIN
REINFORCING STEEL IN PROPER POSITION CONTINUOUSLY DURING CONCRETE
PLACEMENT OPERATIONS.
12. FLOAT FINISH. APPLY FLOAT FINISH TO MONOLITHIC SLAB SURFACES THAT ARE TO
RECEIVE TROWEL FINISH OR OTHER FINISHES. CONSOLIDATE THE SURFACE WITH
POWER-DRIVEN FLOATS, BY HAND-FLOATING IF THE AREA IS SMALL OR
INACCESSIBLE TO POWER UNITS. CHECK AND LEVEL THE SURFACES PLANE ON THE
SURFACE TO A TOLERANCE NOT EXCEEDING 1/4 IN. IN 10 FT. WHEN TESTED WITH A
10 FT. STRAIGHT EDGE PLACED IN THE SURFACE AT NOT LESS THAN 2 DIFFERENT
ANGLES. CUT DOWN HIGH SPOTS AND FILL ALL LOW SPOTS. UNIFORMLY SLOPE
SURFACES TO DRAINS. IMMEDIATELY AFTER LEVELING, RE-FLOAT THE SURFACE TO
A UNIFORMLY SMOOTH, GRANULAR SURFACE.
13. TROWEL FINISH. APPLY TROWEL FINISH TO MONOLITHIC SLAB SURFACES THAT ARE
TO BE EXPOSED TO VIEW. AFTER FLOATING, BEGIN THE FIRST TROWEL FINISH
OPERATION USING A POWER-DRIVEN TROWEL. CONSOLIDATE THE CONCRETE
SURFACE BY FINAL HAND TROWELING WITH A SURFACE PLANE TOLERANCE NOT
EXCEEDING 1/8 IN. IN 10 FT. WHEN TESTED WITH A 10 FT. STRAIGHT EDGE. GRIND
SMOOTH SURFACE DEFECTS WHICH WOULD TELEGRAPH THROUGH APPLIED
FLOORING SYSTEM.
14. BROOM FINISH. FINISHES THAT ARE EXPOSED AND SUBJECT TO FOOT TRAFFIC
SHALL RECEIVE A BROOM FINISH WITH A TEXTURE OF PLUS OR MINUS 1/16 IN. OR
AS DESIGNATED IN THE STRUCTURAL DRAWINGS.
15. FLOOR SLAB DAMP-PROOFING MEMBRANE (VAPOR BARRIER) SHALL BE 6 MIL.
POLYETHYLENE FILM, UNLESS OTHERWISE NOTED, "VISQUEEN" OR EQUAL,
INSTALLED OVERFILL AT FLOOR SLAB OF ENCLOSED BUILDING AREA LOCATIONS.
LAP MINIMUM 24 IN. WITH TOP LAP IN THE DIRECTION OF SPREADING CONCRETE.
EXTEND VAPOR BARRIER INTO BEAM TRENCHES 6 IN. BELOW HAUNCH.
16. PRIOR TO PLACING CONCRETE, INSPECT VAPOR BARRIER TO ENSURE THERE ARE
NO HOLES OR TEARS.
WOODS, PLASTICS, AND COMPOSITES
1. ALL WORK SHALL BE ERECTED PLUMB, TRUE AND IN ACCORDANCE WITH
DRAWINGS AND SPECIFICATIONS. WORK SHALL COMPLY WITH ALL STRUCTURAL
DRAWINGS, NOTES, AND SPECIFICATIONS. EXCESSIVELY SCUFFED, SCRATCHED,
DENTED OR OTHERWISE DAMAGED WOOD MUST BE REPLACED. ALL FRAMING
WORK TO CONFORM TO LOCAL BUILDING CODES AND ENGINEERING
REQUIREMENTS.
2. CONFORM TO THE LATEST GRADING RULES OF THE LUMBER MANUFACTURERS
ASSOCIATION UNDER WHOSE RULES THE LUMBER WAS PRODUCED.
3. SILL OR BASE PLATES IN CONTACT WITH CONCRETE FOUNDATIONS, EXPOSED TO
EXTERIOR CONDITIONS, OR WITHIN 18" OF GROUND LEVEL SHALL BE ACQ TREATED.
FOR A PIER AND BEAM, OR WOOD PILING FOUNDATION, ALL LUMBER BELOW THE
FLOOR JOISTS SHALL BE TREATED. ALL STAIRS AND DECKS SHALL BE TREATED.
ALL TREATED WOOD TO BE MARKED AMERICAN WOOD PROTECTION ASSOCIATION
(A.W.P.A. AND STAMP) OR WESTERN WOOD PRESERVERS INSTITUTE (W.W.P.I. AND
STAMP). MARK SHALL BE VISIBLE WHEN INSTALLED. ONLY HOT DIPPED GALVANIZED
OR STAINLESS-STEEL FASTENERS APPROVED FOR USE WITH ACQ TREATED
LUMBER SHALL BE USED. NO ALUMINUM MATERIALS SHALL BE USED IN DIRECT
CONTACT WITH ACQ TREATED WOOD.
4. CARPENTRY SHALL INCLUDE ALL ROUGH AND DRESSED LUMBER AND ALL WORK IN
CONNECTION WITH MATERIAL INSTALLATION. THE CONTRACTOR SHALL DO ALL
CUTTING AND FRAMING AS REQUIRED BY ANY OTHER TRADE FOR THE COMPLETION
OF CONSTRUCTION. ALL WORK SHALL BE DONE ACCURATELY, NEATLY AND
SECURELY FITTED IN THE MOST WORKMANLIKE MANNER IN ACCORDANCE WITH
THE WORKING DRAWINGS. ALL FRAMING TO BE PER DRAWINGS. FRAMING TO
INCLUDE ANY FURRING OR "CUT-OUTS" NECESSARY FOR INSTALLATION OF AIR
CONDITIONING AND OTHER MEP SYSTEMS.
5. LUMBER SHALL BE CLASSIFIED, AND GRADE MARKED TO THE CODES AND
REQUIREMENTS OF THE MANUFACTURER'S ASSOCIATIONS OR RESIDENTIAL
STANDARDS OF THE PARTICULAR REGION. LUMBER SHALL BE LIVE STOCK,
THOROUGHLY SEASONED, AND WELL MANUFACTURED. MATERIALS GENERALLY
SHALL BE FREE FROM WARP THAT CANNOT BE CORRECTED BY BRIDGING OR
NAILING. REFERENCE STRUCTURAL NOTES FOR ALL STRUCTURAL WOOD MEMBER
REQUIREMENTS.
6. ALL PLYWOOD WHICH HAS ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO
THE ELEMENTS SHALL BE EXTERIOR TYPE. PLYWOOD MANUFACTURED OR
ORIGINATING IN CHINA SHALL NOT BE USED.
a) EXTERIOR SHEAR WALL SHEATHING SHALL BE APA EXPOSURE 1 RATED
CDX PLYWOOD OR OSB. ALL OTHER WALL SHEATHING SHALL BE CDX
PLYWOOD OR OSB OR EQUIVALENT ZIP SYSTEM. REFER TO STRUCTURAL
DRAWINGS FOR SPECIFICATIONS AND INSTALLATION REQUIREMENTS.
b) ALL ROOF SHEATHING TO BE CDX PLYWOOD OR OSB OR EQUIVALENT
ZIP SYSTEM. SHEATHING WITH RADIANT BARRIER TO MEET APA EXPOSURE 1
RATING. REFER TO STRUCTURAL DRAWINGS FOR SPECIFICATIONS AND
INSTALLATION REQUIREMENTS.
c) FLOOR SHEATHING SHALL BE 3/4" THICK PLYWOOD SHEATHING TO MEET
APA EXPOSURE 1 RATED PLYWOOD. GLUED AND SCREWED; REFER TO
STRUCTURAL DRAWINGS FOR SPECIFICATIONS AND ADDITIONAL
INSTALLATION REQUIREMENTS.
7. ALL CLIPS, STRAPS, HANGERS, HOLD-DOWNS, FASTENERS, AND ASSOCIATED
DEVICES SHALL BE GALVANIZED (PER STRUCTURAL), AS MANUFACTURED BY
SIMPSON STRONG-TIE CO. INC OR OTHER APPROVED MANUFACTURES. INSTALL
PER MANUFACTURERS SPECIFICATIONS.
8. ALL BEAMS SHALL BE MADE UP OF A NUMBER OF 2X JOISTS OR
ENGINEER-SPECIFIED ANTHONY POWER BEAM, OR EQUIVALENT.
9. LATERALLY SUPPORT AT ENDS AND AT EACH SUPPORT BY SOLID BLOCKING
EXCEPT WHERE THE ENDS OF JOISTS ARE NAILED TO A HEADER, BAND, RIM JOIST,
OR ADJOINING STUD. SOLID BLOCKING SHALL BE NO LESS THAN 1 1/2" THICKNESS
AND SHALL MATCH THE DEPTH OF THE JOISTS.
10. INSTALL JOIST HANGERS AT EACH END OF EACH CEILING JOIST WHERE REQUIRED.
VERIFY LIGHT FIXTURE CENTERLINE LOCATIONS AND JOIST/TRUSS PLACEMENT
PRIOR TO INSTALLATION.
11. BRIDGING MUST BE #2 SOUTHERN YELLOW PINE OR FIR, GRADED AND STAMPED
(FIR TO BE USED IN NON-LOAD BEARING AREAS ONLY). REFER TO STRUCTURAL
DRAWINGS.
12. PREMANUFACTURED WOOD OPEN WEB FLOOR JOISTS ABLE TO SUPPORT
CODE-REQUIRED LIVE AND DEAD LOADS. PROVIDE AS INDICATED ON DRAWINGS.
SUBMIT SHOP DRAWINGS SIGNED AND SEALED BY A PROFESSIONAL STRUCTURAL
ENGINEER LICENSED TO PRACTICE IN THE STATE OF NEW MEXICO FOR REVIEW
AND APPROVAL. SEE STRUCTURAL FOR ADDITIONAL REQUIREMENTS.
13. REMOVE ALL UNUSED WOOD, INCLUDING FORM LUMBER, SCRAP LUMBER,
SHAVINGS AND SAWDUST IN CONTACT WITH THE GROUND. LEAVE NO WOOD
BURIED IN FILL OR BACKFILL.
EXTERIOR FINISH CARPENTRY
1. GENERAL: USE GALVANIZED, STAINLESS STEEL OR TREATED NAILS AS REQUIRED.
INSTALL PER MANUFACTURER'S INSTRUCTIONS.
2. FIBER CEMENT SIDING AND TRIM: MANUFACTURED BY JAMES HARDIE OR
EQUIVALENT; TO BE CONCEALED NAILED INSTALLATION, UNLESS NOTED
OTHERWISE; IN COMPLIANCE WITH STRUCTURAL DESIGN PRESSURE
REQUIREMENTS, WHERE REQUIRED. SHALL INCLUDE ALL REQUIRED ACCESSORIES
FOR A COMPLETE INSTALLATION.
3. EXTERIOR MATERIALS:
a) FASCIA BOARDS AND TRIM: 'HZ10' HARDIE TRIM, TEXTURED FINISH, PRE-PRIMED. SMOOTH FINISH MAY BE SUBSTITUTED IF TEXTURED FINISH IS
UNAVAILABLE.
b) LAP SIDING: 'HZ10' HARDIE PLANK, 8 1/4", PRE-PRIMED. SMOOTH FINISH
MAY BE SUBSTITUTED IF TEXTURED FINISH IS UNAVAILABLE
c) SOFFIT: 'HZ10' HARDIE SOFFIT, CONTINUOUS, VENTED, PRE-PRIMED.
SMOOTH FINISH MAY BE SUBSTITUTED IF TEXTURED FINISH IS UNAVAILABLE.
PROVIDE METAL SCREEN AT SOFFIT OPENINGS.
d) BOARD AND BATTEN PANELS (OPTION): 'HZ10" HARDIE PANEL VERTICAL
SIDING WITH 'HZ10' HARDIE TRIM BATTENS, SMOOTH OR TEXTURED FINISH,
PRE-PRIMED.
e) SHAKES AT PORCH GABLE (OPTION): 'HZ10' HARDIESHINGLE
STAGGERED EDGE SHINGLES, PRE-PRIMED.
f) PORCH SOFFIT: 'HZ10' HARDIEPANEL, SMOOTH OR TEXTURED FINISH, PRE-PRIMED.
4. TRIM AND DECORATIVE MILLWORK SHALL BE INSTALLED IN COMPLIANCE WITH
LOCAL REQUIREMENTS; SHALL INCLUDE ALL REQUIRED FASTENERS AND
ACCESSORIES FOR COMPLETE INSTALLATION.
5. COLUMN WRAP SHALL BE PREFABRICATED; DESIGN, AS INDICATED ON DRAWINGS.
6. LOUVER / GABLE VENT SHALL BE DESIGNED AS INDICATED ON DRAWINGS; PROVIDE
METAL SCREENING AT OPENINGS.
INTERIOR FINISH CARPENTRY
1. PROVIDE WEATHER PROTECTION FOR ALL MILLWORK DELIVERED TO THE JOB.
2. INSPECT FINISH MATERIALS (TRIM, DOORS, ETC.) TO ENSURE THAT NO SUB-GRADE,
DEFECTIVE OR MACHINE MARKED PIECES ARE INSTALLED. USE ONE PIECE FOR
LENGTH WHEREVER POSSIBLE.
3. WINDOW STOOL AND APRON ARE TO BE 3/4" THICK WHITE PINE STOOL WITH
GYPSUM BOARD JAMB; CASING. TO BE PAINTED TO MATCH DOOR WOOD TRIM.
4. CLOSETS ARE TO HAVE 1 1/2" DIAMETER WOOD RODS, 3/4" THICK WOOD SHELVING
WITH 3 4"X1 12" SOLID WOOD EDGE BANDING, TO BE PAINTED.
5. LAUNDRY ROOM IS TO HAVE ONE ROW OF 3/4" THICK WOOD SHELVING WITH 3 4"X1
12" SOLID WOOD EDGE BANDING ABOVE WASHER/DRYER PER INTERIOR
ELEVATIONS, TO BE PAINTED.
6. PANTRY TO HAVE FIVE (5) 3/4" THICK WOOD SHELVING WITH 3 4"X1 12" SOLID WOOD
EDGE BANDING, TO BE PAINTED. ADD ADDITIONAL SUPPORT AS NEEDED.
7. ALL BATHROOM CABINETS AND DOORS TO BE FACE FRAME TYPE PLYWOOD / SOLID
WOOD, PRE- FINISHED OR APPROVED EQUIVALENT. COLOR TO BE PER
PRE-SELECTED FINISH SCHEDULE.
8. ALL KITCHEN CABINETS AND DOORS TO BE FACE FRAME TYPE PLYWOOD / SOLID
WOOD, PRE- FINISHED OR APPROVED EQUIVALENT. COLOR TO BE SELECTED BY
OWNER FROM PRE-SELECTED FINISH SCHEMES.
NOTE: NO PARTICLE BOARD SHALL BE EXPOSED TO THE ATMOSPHERE*
9. NO NAIL OR SCREW HOLES OR OTHER FASTENING SHALL BE VISIBLE ON THE
EXTERIOR.
10. TOE BASES TO BE 3 1/2" HIGH, 3" DEEP.
11. THE CABINET FABRICATOR AND GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL REQUIRED APPLIANCE "CUT-OUTS" TAKEN FROM THE MANUFACTURER'S
INSTALLATION INSTRUCTIONS AND TEMPLATES, AS SELECTED.
12. CABINET HINGES ARE TO BE 1/2" OVERLAY CONCEALED HINGES. PROVIDED BY
MANUFACTURER, POLISHED OR BRUSHED CHROME FINISH.
13. DOOR CATCHES ARE TO BE POLISHED OR BRUSHED CHROME FINISH AS PROVIDED
BY MANUFACTURER
14. KITCHEN COUNTERTOPS ARE TO BE PLASTIC LAMINATE, MATTE FINISH BY
FORMICA OR EQUAL COUNTER, ADHERED TO 3/4" PARTICLE BOARD SUBSTRATE
MADE WITH EXTERIOR GLUE AND BINDERS CONTAINING NO UREA FORMALDEHYDE.
WITH 4" HIGH INTEGRAL BACKSPLASH WITH ROLL EDGE. SIDE SPLASH AS
REQUIRED. ALL LAMINATE TO BE HANDLED AND INSTALLED IN ACCORDANCE WITH
THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. WATERPROOF
AROUND SINK CUT OUT PERIMETER TOP, EDGE, AND BOTTOM. CONTRACTOR TO
PROVIDE OWNER WITH PRE- SELECTED COLOR SAMPLES FOR COLOR SELECTION.
15. BATHROOM VANITY IS TO BE WITH INTEGRAL SINK, 1/2" THICK SOLID POLYMER
MATERIAL ADHESIVELY JOINED WITH INCONSPICUOUS SEAMS; STANDARD EDGE
DETAILS WITH INTEGRAL BOWL. PROVIDE COVED BACKSPLASH AND SIDE
SPLASHES.
THERMAL AND MOISTURE PROTECTION
1. MATERIALS: ONE PART 100% LIQUID POLYMER, POLYSULFIDE OR ACRYLIC BASE
COMPOUND, NON-SAGGING, NON- STAINING, GUN CONSISTENCY. ROD STOCK
BACKUP SHALL BE FLEXIBLE, CLOSED CELL, EXPANDED POLYETHYLENE ROUND
RODDING 1-1/3 TIMES THE JOINT WIDTH IN DIAMETER CONFORMING TO FEDERAL
SPECIFICATIONS HH-F-341, TYPE 1, CLASS A AND B. COLOR TO BE
MANUFACTURER'S STANDARD AND CHEMICALLY COMPATIBLE WITH SUBSTRATE
PER MANUFACTURER'S RECOMMENDATION. SEALANT TO HAVE A MINIMUM 20-YEAR
WARRANTY.
2. LOCATION: PROVIDE SEALANT AT ALL JOINTS AND RECESSES IN EXTERIOR AND
INTERIOR CONSTRUCTION WHERE REQUIRED TO PREVENT INFILTRATION OF
WATER, MOISTURE, AIR, SOUND, AND LIGHT. PLACE CONTINUOUS BEAD OF
ACOUSTICAL SEALANT BETWEEN EXTERIOR SILL PLATE AND FLOOR.
3. APPLICATION: BEFORE APPLYING SEALANTS, ALL SURFACES SHALL BE
ABSOLUTELY CLEAN OF DIRT, GREASE, LOOSE MATERIAL, AND FOREIGN MATTER.
APPLY PRIMERS AND SEALANTS IN STRICT ACCORDANCE WITH MANUFACTURER'S
PRINTED INSTRUCTIONS. ALL SEALANTS IN EXPOSED OR VISIBLE LOCATIONS TO BE
TOOLED SMOOTH AS RECOMMENDED BY SEALANT MANUFACTURER. ALL WINDOW
TOPS, SIDES AND BOTTOMS OF DOOR THRESHOLDS TO HAVE FULL BED OF
SEALANT. COMPLETE SEALANT INSTALLATION BEFORE THE FINAL COAT OF PAINT IS
APPLIED.
4. ALL BUILDING INSULATION TO HAVE A FLAME-SPREAD RATING OF 25 AND A
SMOKE-DEVELOPED RATING OF 50.
5. FOR ROOFS AND CEILINGS USE FORMALDEHYDE FREE, R-38 MINIMUM BORATE
TREATED CELLULOSE OR R-38 MINIMUM FIBERGLASS BLOW-IN, SPRAY FOAM OR
BLOW-IN MINERAL WOOL INSULATION MATERIAL, ASTM E-84, CLASS A,
NON-COMBUSTIBLE. PROVIDE INSULATION BAFFLES AT ROOF TO ACCOMMODATE
VENTING. ATTIC INSULATION CARD AND ATTIC RULERS SHOULD BE ON SITE.
CONSULT ENERGY CALCULATION FOR REQUIRED R-VALUE.
6. FOR EXTERIOR WALLS, INSULATE USING IBC APPROVED INSULATION WITH MINIMUM
R-VALUE BY CLIMATE ZONE. CONSULT ENERGY CALCULATION FOR REQUIRED
R-VALUE. ENSURE CONSTRUCTION MEETS ENERGY STAR REQUIREMENTS.
7. WHEN HOUSE IS ELEVATED, FOR UNDERFLOOR USE FORMALDEHYDE FREE,
UNFACED, FIBERGLASS, SPRAY FOAM OR MINERAL WOOL BATT INSULATION
MATERIAL, ASTM E-84, CLASS A, NON-COMBUSTIBLE.
8. ALL VOIDS AROUND WINDOWS, EXTERIOR DOORS, AND WALL PENETRATIONS ARE
TO BE FILLED WITH HIGH-DENSITY FOAMED- IN-PLACE THERMAL INSULATION, AND
CAULKED, SEALED OR GASKETED AS NEEDED WHEN IN CONTACT WITH DRYWALL.
DO NOT USE PRODUCTS CONTAINING UREA FORMALDEHYDE.
9. USE BAFFLES AROUND ALL HEAT SOURCES AND AT THE PLYWOOD DECK BETWEEN
THE JOISTS.
10. ALL MATERIALS THAT WILL BE COVERED MUST BE AT OR BELOW 19% MOISTURE
CONTENT BEFORE BEING COVERED UP
ROOFS
1. SHINGLE ROOF:
a. 30-YEAR ELK, CELOTEX OR GAF OR COMPARABLE ALTERNATE COMPOSITION
ARCHITECTURAL SHINGLES, FIBERGLASS-BASED ASPHALT SHINGLES, ASTM
D3161, CLASS F WITH TYPE I - SELF SEALING; UL RATING OF A AND WIND
RESISTANCE LABEL TO MEET DESIGNATED STRUCTURAL WIND DESIGN
PRESSURES; 220 MINIMUM LB. / SQUARE; SQUARE TYPE; INSTALLED PER
MANUFACTURER'S DETAILS.
b. ALL VALLEYS TO BE WOVEN OR CLOSED-CUT TO COMPLY WITH WINDSTORM
GUIDELINES AND PER MANUFACTURER'S RECOMMENDATIONS.
c. NAIL THE ROOF DECK WITH 8D RING-SHANK NAILS. 8D RING-SHANK NAILS MUST
BE AT LEAST 0.113-IN. DIAMETER AND 2-3/8-IN. LONG. DOCUMENTATION:
PHOTOGRAPH THE FASTENER PACKAGE OR THE NAILS PRIOR TO
INSTALLATION.
d. INSTALL ICE AND WATER SHIELD UNDERLAYMENT TO ALL ROOF SHEATHING.
INSTALL UNDERLAYMENT TO MANUFACTURER SPECIFICATION.
DOCUMENTATION: PHOTOGRAPH THE COMPLETED INSTALLATION
e. INSTALL DRIP EDGE OVER THE UNDERLAYMENT AT RAKES AND EAVES AND
FASTEN AT 4 IN. O.C. STAGGERED. DOCUMENTATION: NONE NEEDED, WILL BE
CERTIFIED AT THE FINAL INSPECTION
2. WARRANTY: CONTRACTOR WARRANTY SHALL INCLUDE ALL MATERIALS AND LABOR
TO REPAIR ANY DEFECTS OR LEAKS THAT DEVELOP AND REPAIR OR MAKE GOOD
ANY DAMAGE CAUSED BY LEAKS AND ROOF REPAIRS FOR A PERIOD OF ONE (1)
YEAR FROM DATE OF SUBSTANTIAL COMPLETION. MANUFACTURER'S WARRANTY
SHALL BE 30 YEAR "NO DOLLAR LIMIT" WARRANTY.
3. MATERIALS: SHEET METAL SHALL BE 26-GAUGE UNLESS NOTED OTHERWISE AK
STEEL ZINCGRIP STEEL, OR EQUAL. SEAMS SHALL BE LOCKED AND SOLDERED
WITH 50% PIG LEAD WITH NON-CORROSIVE FLUX. JOINTS SHALL BE LAPPED 6" AND
BEDDED IN PLASTIC ROOFER'S CEMENT FS-SS-C-153. FASTENERS IN CONTACT
WITH GALVANIZED IRON SHALL BE GALVANIZED, OR CADMIUM PLATED STEEL
SCREWS, OR GALVANIZED OR CADMIUM PLATED STRONG-HOLD TYPE NAILS. ALL
SHEET METAL WORK SHALL CONFORM TO SMACNA. SHEET METAL FLASHING
REQUIRED AT ALL ROOF EDGE, VALLEYS, TIE- INS, CRICKETS, WALL/ROOF
INTERSECTIONS, AND ALL EXTERIOR DOORS AND WINDOW HEADS.
4. SHEET METAL FOR ROOFS, WINDOWS, AND GUTTERS
1. ROOF EDGE FLASHING AND DRIP EDGES: ANGLED. 28-GAUGE GALVANIZED
STEEL;
2. ROOF VALLEYS AND TIE-INS: 26-GAUGE GALVANIZED STEEL.
3. WINDOWS AND DOORS: Z-BAR FLASHING OR EQUIVALENT INSTALLED PER
MANUFACTURER'S INSTRUCTIONS.
4. GUTTERS AND DOWNSPOUTS:
a) PLAIN HALF-ROUND: 6" WIDE AND 4" DIAMETER DOWNSPOUT, MINIMUM.
22-GAUGE GALVANIZED STEEL, OR ALUMINUM PREFINISHED.
b) STANDARD K-STYLE: 6" WIDE AND 4" X 5" DOWNSPOUT, MINIMUM.
22-GAUGE GALVANIZED STEEL, OR ALUMINUM PREFINISHED.
c) PROVIDE SPLASH BLOCK AT EACH DOWNSPOUT OR CONTROL ALL RUN
OFF AND EROSION.
5. RIDGE VENTS AND OTHER ROOF VENTS; NON-COMBUSTIBLE CONSTRUCTION;
INSTALL 1/8" METAL SCREEN AT ALL VENT OPENINGS; MUST MEET STRUCTURAL
REQUIREMENTS. RIDGE VENTS ARE TO BE SHINGLE OVER TYPE.
6. ROOF UNDERLAYMENT OF THE SEALED ROOF DECK TO MEET THE MINIMUM
REQUIREMENTS OF GOVERNING JURISDITION.
OCCUPANCY: R-3 - RESIDENTIAL
CONSTRUCTION TYPE: VB
NM RESIDENTIAL CODE, 14.7.3 NMAC, 2021 IRC, AS AMENDED
NM ENERGY CONSERVATION CODE, 14.7.2 NMAC
2020 NATIONAL ELECTRIC CODE, NFPA 70
NM PLUMBING CODE, 14.8.2 NMAC, 2021 IPC AS AMENDED
2021 INTERNATIONAL WILDLIFE URBAN INTERFACE (IWUIC)
NM FIRE CODE, 10.25.5 NMAC, 2021 IFC AS AMENDED
NM FUEL GAS CODE, 14.8.3 NMAC, 2021 IFGC AS AMENDED
2021 IECC, AS AMENDED
# DATE DESCRIPTION
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN ANY
FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
ISSUANCE / REVISION
PROJECT LOCATION OR ADDRESS:
CLIENT NAME:
ENGINEERING AND INSPECTIONS, LLC
26-0###
CDBG - DR
NEW MEXICO
PLEXOS GROUP
ISSUE FOR ESTIMATING01/10/2026A
GN-0.10
GENERAL NOTES
DOORS AND WINDOWS
1. ALL DOORS AND WINDOWS SHALL BE INSPECTED TO ENSURE THAT THEY ARE
SQUARE, PLUMB, AND ACCURATE BEFORE INSTALLATION AND COMPLY WITH SIZE,
THICKNESS, AND DESIGN AS SHOWN IN THE CONSTRUCTION DOCUMENTS AND
SCHEDULES AND MEET LOCAL CODES. ALL SCHEDULED DOORS SHALL BE
INSTALLED TO BE PLUMB, LEVEL, AND SQUARE AND OPERATE FREELY, BUT NOT
LOOSELY, AND SHALL BE ADJUSTED TO FUNCTION PROPERLY. DOORS SHALL BE
FREE FROM RATTLING WHEN IN LATCHED POSITION.
2. ALL WOOD DOORS AND WINDOW SHALL CONFORM TO STANDARDS SET BY AWI
(ARCHITECTURAL WOODWORK INSTITUTE) AND NWMA (NATIONAL WOODWORK
MANUFACTURER'S ASSOCIATION). PROVIDE ONE-YEAR MINIMUM GUARANTEE
AGAINST ALL DEFECTS.
3. SCHEDULE: REFERENCE DOOR SCHEDULE ON PLANS FOR SIZES, TYPES,
LOCATIONS, ETC.
4. ALL EXTERIOR DOORS MUST BE FABRICATED AND INSTALLED TO MEET THE
ENGINEERED DESIGN AND ENERGY STAR PER CLIMATE ZONE.
5. VERIFY WITH LOCAL CODE AND ORDINANCES AND PROVIDE "IMPACT" RESISTANT
EXTERIOR DOORS, WHERE REQUIRED BY CODE.
6. INTERIOR DOORS ARE TO BE 6 PANEL OR MATCHING THROUGHOUT HOME.
7. INSTALL LOUVER DOOR WHERE REQUIRED BY CODE FOR VENTILATION.
8. PROVIDE WEATHER STRIPPING ON ALL EXTERIOR DOORS.
9. AT LEAST ONE EXTERIOR DOOR SHALL HAVE ALUMINUM, 2-PIECE INTERLOCKING
THRESHOLD TO MEET ADA REQUIREMENTS. WHEN THE APPLICANT HAS
VERIFICATION OF DISABILITY FORM, WITH NO STEP ENTRANCE SELECTED.
10. CONTRACTOR SHALL COMPLETELY INSTALL FINISH HARDWARE AS REQUIRED,
WITHOUT DAMAGING CABINETRY AND DOOR FINISHES AND IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
11. CONTRACTOR WILL BE RESPONSIBLE FOR ALL HARDWARE DELIVERED TO THE JOB
SITE. HARDWARE MUST ALWAYS BE PROTECTED FROM DAMAGE PRIOR TO AND
AFTER INSTALLATION.
12. EXTERIOR HARDWARE: ALL EXTERIOR DOOR HARDWARE SHALL COMPLY WITH
LOCAL CODE. INCLUDE DOOR LOCKS, HINGES, DOOR STOPS, WEATHER-STRIP, AND
THRESHOLD. PROVIDE COMPRESSIBLE DOOR SEALS WITH RUBBER BOTTOM
GASKET WHERE SOUND MITIGATION IS REQUIRED.
13. INTERIOR HARDWARE: INCLUDE DOOR LOCKS, HINGES AND DOOR STOPS.
BRUSHED CHROME FINISH. BEDROOMS AND BATHROOMS TO HAVE PRIVACY
LOCKSETS. ALL OTHER DOORS SHALL HAVE PASSAGE LOCKSETS.
14. INSTALL LEVER TYPE DOOR HANDLES ON ALL DOORS.
15. ALL ENTRANCE LOCKSETS TO BE KEYED ALIKE (INCLUDING DEADBOLTS) PROVIDE
MINIMUM TWO KEYS TOTAL.
16. ALL WINDOWS MUST BE FABRICATED AND INSTALLED TO MEET THE ENGINEERED
DESIGN PRESSURES. REFER TO STRUCTURAL DRAWINGS. INSTALLATION SHALL BE
ACCORDING TO DETAILS AND MANUFACTURER'S RECOMMENDATIONS TO ASSURE
A WEATHER-TIGHT FIT. ALL FRAMES WILL BE INSTALLED PLUMB, LEVEL AND
SQUARE TO ENSURE PROPER FUNCTIONING WITH REGARD TO SLIDING, LOCKING
AND WEATHERING. REFERENCE WINDOW SCHEDULE ON PLANS FOR SIZES,
LOCATIONS, ETC. IF THERE ARE DISCREPANCIES BETWEEN THE PLANS AND
SPECIFICATIONS, THE SPECIFICATIONS WILL RULE.
17. VERIFY LOCAL CODE AND ORDINANCES AND PROVIDE "IMPACT" RESISTANT
WINDOWS, WHERE REQUIRED BY CODE.
18. SINGLE HUNG, OPERABLE TYPE VINYL WINDOWS, INSULATED FRAME WITH
FACTORY GLAZED, LOW-E INSULATED GLASS UNITS COMPRISED OF 2 LAYERS OF
GLASS - PROVIDE IMPACT RESISTANT GLASS WHERE REQUIRED BY CODE.
WINDOWS SHALL BE ENERGY STAR RATED FOR THE PROPER CLIMATE ZONE.
19. EACH OPEN AREA OF OPERABLE WINDOWS MUST BE SUPPLIED WITH REMOVABLE
SCREENS COVERING THE OPERABLE AREA. SCREEN MATERIAL IS NOT TO BE LESS
THAN 8-8X16 MESH PER INCH.
20. ALL OPERABLE WINDOWS MUST HAVE A SECURITY DEVICE/LOCK.
FINISHES
1. CEILINGS ARE TO BE 1/2" THICK, ANSI/ASTM C30, PAINTED GYPSUM BOARD WITH
TAPE AND ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION.
2. WALLS ARE TO BE 1/2" THICK ANSI/ASTM C30, PAINTED GYPSUM BOARD WITH TAPE
AND ACCESSORIES. (BATHROOM WALL SHALL BE REINFORCED WITH SOLID 2X12
LUMBER FOR POTENTIAL INSTALLATION OF GRAB BARS. REFER TO FLOOR PLANS
FOR REINFORCED WALL LOCATIONS.).
3. MAXIMUM VARIATION OF FINISHED GYPSUM BOARD SURFACE FROM TRUE
FLATNESS OF 1/4 INCH (6.35 MM) IN 4 FEET (1219 MM) IN ANY DIRECTION.
4. BATHROOMS, KITCHEN, WASHER / DRYER CLOSET (ALL WET AREAS), USE
MOISTURE RESISTANT GYPSUM BOARD, ANSI/ASTM C630.
5. CORNER AND EDGE BEADS IS TO BE USG OR APPROVED EQUAL; QUARTER ROUND
OR 90-DEGREE CORNER BEAD;
6. TAPE AND JOINT CEMENT TO BE USG OR APPROVED EQUAL.
PAINT AND COATINGS
7. ALL PAINTS, COATINGS, AND FINISHES ARE TO BE APPLIED IN STRICT ACCORDANCE
WITH MANUFACTURER'S DIRECTIONS AND CARRY A MANUFACTURER'S WARRANTY.
8. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL MAKE CERTAIN THAT THE
SURFACE TO BE COVERED IS IN PROPER CONDITION TO RECEIVE THE FINISH
SPECIFIED. THE COVERAGE OF THE SURFACE SHALL BE HELD TO DENOTE THE
ACCEPTANCE OF THE SURFACE.
9. ALL INTERIOR SPACES ARE TO BE PRIMED AND PAINTED AS SCHEDULED. INTERIOR
PAINTING WILL NOT EXCEED A TOTAL OF THREE PAINT COLORS; ONE WALL COLOR,
ONE CEILING COLOR, AND ONE TRIM COLOR. COLORS TO BE SELECTED FROM
PRE-SELECTED COLOR SCHEMES.
10. EXTERIOR SURFACES TO BE PRIMED AND RECEIVE MINIMUM OF TWO TOP COATS
OF PAINT. COLORS TO BE SELECTED FROM PRE-SELECTED COLOR SCHEMES.
SPECIALTIES
1. BATHROOM ACCESSORIES SHALL BE ASI, AMERICAN STANDARD OR OTHER
APPROVED. ALL BATHROOM ACCESSORIES SHALL BE SUPPLIED BY ONE
MANUFACTURER.
2. TOWEL BARS, TWO (2), 18" LONG REQ.
3. TOILET TISSUE HOLDER, SINGLE ROLL.
4. MIRROR, HEIGHT ABOVE FINISHED FLOOR INDICATED ON DRAWINGS.
5. TUB/SHOWER ENCLOSURE: INSTALL NEW WHITE FIBERGLASS SHOWER/TUB
ENCLOSURE ABLE TO RECEIVE APPROVED GRAB BARS AS INDICATED ON PLANS.
INCLUDE NEW RAMP OVERFLOW AND DRAIN WITH STOP VALVE AND WATER
CONNECTIONS. VALVE MUST BE WASHERLESS AND HIGH-QUALITY
CHROME-PLATED BRASS UNIT WITH SINGLE CONTROL, LEVER TYPE PLUMBING
FIXTURE HANDLES. INSTALL PLUMBING PIPE ACCESS. PROVIDE SHOWER CURTAIN
ROD, BRUSHED CHROME FINISH.
6. N/A
7. SINK FAUCET WITH AERATOR SHOULD MEET IBC 2021 RESIDENTIAL CODE, SECTION
P2903, TABLE 2903.1; CHROME OR BRUSHED CHROME FINISH.
8. TOILETS SHOULD MEET IBC 2021 RESIDENTIAL CODE, SECTION P2903, TABLE 2903.1,
ELONGATED; 17”-19” FLOOR TO BOWL RIM HEIGHT, INCLUDING THE SEAT; CHROME
OR BRUSHED CHROME FINISH HANDLE.
9. SHOWERHEADS TO BE WATERSENSE LABELED (1.8 GALLONS PER MINUTE AT 80 PSI.
CHROME OR BRUSHED CHROME FINISH.
10. STACK REQUIRED. EVERY BUILDING SHALL HAVE AT LEAST ONE STACK THE SIZE OF
WHICH IS NOT LESS THAN 3 INCHES (76MM) IN DIAMETER. SUCH STACK SHALL RUN
UNDIMINISHED IN SIZE AND AS DIRECTLY AS POSSIBLE FROM THE BUILDING DRAIN
THROUGH TO THE OPEN AIR OR TO A VENT HEADER THAT EXTENDS TO THE OPEN
AIR.
11. RA REQUIREMENTS WHEN APPLICABLE, PROVIDE 36" HALLWAYS,WIDE ENOUGH TO
ACCOMMODATE A STANDARD WHEELCHAIR; ADEQUATE TURNING RADIUS FOR A
WHEELCHAIR IN THE KITCHEN; ADEQUATE TURNING RADIUS FOR A WHEELCHAIR IN
BOTH BATHROOMS; ALL DOORS INSTALLED WITH LEVERS INSTEAD OF KNOBS;
EXTERIOR DOORS, ALL BEDROOM.
12. RA-KITCHEN REQUIREMENTS WHEN APPLICABLE, PROVIDE WHEELCHAIR
ACCESSIBLE COOK TOP (KNOBS ON FRONT OF APPLIANCE).
EQUIPMENT
1. ALL EQUIPMENT SHALL BE ENERGY STAR RATED (OR EQUIVALENT). EQUIPMENT
ITEMS TO BE PROVIDED ACCORDING TO THE FOLLOWING SELECTION LIST
(RESIDENTIAL RANGES ARE NOT AVAILABLE AS ENERGY STAR):
a. RANGE: 30" ELECTRICAL RANGE WITH SMOOTH OR COIL TOPS.
b. MICROWAVE UNIT: WITH INTEGRAL EXHAUST FAN AND LIGHT; EXHAUST
TO EXTERIOR.
c. REFRIGERATOR: 18 CUBIC FOOT MINIMUM SIZE UNIT WITH AN ICE-MAKER.
d. SINK: 2 EQUAL SIZED COMPARTMENTS, 22" X 33", 6" DEEP MINIMUM, STAINLESS STEEL FINISH.
e. DISHWASHER AND GARBAGE DISPOSAL: INSTALL 24" BUILT-IN, MULTI-STAGE DISHWASHER; 1/2-HP CONTINUOUS FEED GARBAGE DISPOSAL.
2. DRYER EXHAUST DUCTS FOR CLOTHES DRYERS SHALL TERMINATE ON THE
OUTSIDE OF THE BUILDING AND SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER.
SCREENS SHALL NOT BE INSTALLED AT THE DUCT TERMINATION. DUCTS SHALL
NOT BE CONNECTED OR INSTALLED WITH SHEET METAL SCREWS OR OTHER
FASTENERS THAT WILL OBSTRUCT THE EXHAUST FLOW. CLOTHES DRYER EXHAUST
DUCTS SHALL NOT BE CONNECTED TO A VENT CONNECTOR, VENT OR CHIMNEY.
CLOTHES DRYER EXHAUST DUCTS SHALL NOT EXTEND INTO OR THROUGH DUCTS
OR PLENUMS. CLOTHES DRYER EXHAUST DUCTS SHALL BE SEALED
2. PROVIDE HOOK-UP AND VENTING FOR ELECTRIC CLOTHES WASHER AND DRYER.
DRYER EXHAUST DUCT TERMINATIONS SHALL BE IN ACCORDANCE WITH THE
DRYER MANUFACTURER'S INSTALLATION INSTRUCTIONS. WHERE THE
MANUFACTURER'S INSTRUCTIONS DO NOT SPECIFY A TERMINATION LOCATION, THE
EXHAUST DUCT SHALL TERMINATE NOT LESS THAN 3 FEET (914 MM) IN ANY
DIRECTION FROM OPENINGS INTO BUILDINGS, INCLUDING OPENINGS IN
VENTILATED SOFFITS. DRYER EXHAUST VENT CONNECTION SHALL BE TO
EXTERIOR. CLOTHES WASHER AND DRYER ARE NOT IN THE CONTRACT, NOT TO BE
SUPPLIED.
3. VENTING FROM RANGE HOOD SHALL DISCHARGE TO THE OUTDOORS THROUGH
SHEET METAL DUCTS CONSTRUCTED OF GALVANIZED STEEL, STAINLESS STEEL,
ALUMINUM OR COPPER. SUCH DUCTS SHALL HAVE SMOOTH INNER WALLS, SHALL
BE AIR TIGHT, SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER, AND SHALL BE
INDEPENDENT OF ALL OTHER EXHAUST SYSTEMS.
4. IN OTHER THAN GROUP I-1 AND I-2, WHERE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER’S INSTRUCTIONS AND WHERE MECHANICAL OR NATURAL
VENTILATION IS OTHERWISE PROVIDED IN ACCORDANCE WITH CHAPTER 4 OF THE
2021 IMC, LISTED AND LABELED DUCTLESS RANGE HOODS SHALL NOT BE
REQUIRED TO DISCHARGE TO THE OUTDOORS. DUCTLESS HOODS ARE NOT
ALLOWED AS A APART OF THE PROGRAM REQUIREMENTS. ALL RANGE HOODS ARE
TO BE VENTED TO THE EXTERIOR. REFERENCE NOTE NUMBER 3.
5. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR AND
CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL PLUMBING CODE, CITY,
COUNTY, AND STATE PLUMBING AND HEALTH CODES AND/OR LOCAL ORDINANCES,
MOST RECENT EDITION.
6. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND FILE ALL
NECESSARY DRAWINGS WITH THE CITY AND/OR COUNTY AGENCY HAVING
JURISDICTION.
7. SOIL WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC AS REQUIRED BY CODE.
ALL WATER PIPING (BOTH HOT AND COLD) SHALL BE PEX (OR APPROVED EQUAL)
AND SHALL BE SIZED AND INSTALLED SO THAT NO RUNNING WATER NOISE IS
AUDIBLE IN PIPING SYSTEM. ALL HOT AND COLD-WATER PIPING SHALL BE
INSTALLED INSIDE OF BUILDING INSULATION TO PREVENT FREEZING. WHERE THIS
IS NOT PRACTICAL, PIPING IS TO BE INSULATED - MINIMUM R-3.5. SWING JOINTS,
EXPANSION LOOPS, AND OFFSETS SHALL BE PROVIDED AS NECESSARY TO ALLOW
FOR EXPANSION OF PIPING.
8. WHERE EXISTING NATURAL GAS SERVICE EXISTS, UTILITY COMPANY SHALL
REMOVE GAS METER AND GAS LINE(S) TO EDGE OF PROPERTY AND CAP SERVICE.
9. PROVIDE HEAVY BRASS HOSE-BIBS WITH INSULATED CUT-OFFS, MOUNT WITH
HANDLES 4" FROM WALL IN LOCATIONS AS SHOWN AND NOTED ON DOCUMENTS.
DO NOT LOCATE HOSE BIB ON FRONT ELEVATION OF HOUSE OR ON PORCHES,
BALCONIES, OR DECKS. U.N.O.
10. PROVIDE ESCUTCHEONS FOR EXPOSED PIPING PASSING THROUGH FLOORS,
WALLS, PARTITIONS, AND CEILINGS. POLISHED, OR BRUSHED CHROME FINISH.
11. CONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING FIXTURES REQUIRED
INCLUDING ALL ITEMS SUCH AS TRAPS, SUPPLY TUBING, STOP AND BASIN COCKS,
ETC. ALL FIXTURES SHALL BE FURNISHED AND INSTALLED WITHOUT DAMAGE OR
REPLACED IN CASE OF DAMAGE.
12. ONE 40 GALLON ELECTRIC WATER HEATER - GLASS LINED, QUICK RECOVERY, WITH
A MINIMUM FIVE (5) YEAR WARRANTY. PROVIDE 2-1/2" GALVANIZED, PLASTIC, OR
EQUAL DRAIN PAN. ENERGY STAR RATED; MINIMUM 0.95 EF (ELECTRIC).
13. SINKS, LAVATORIES, WATER CLOSETS, BATHTUBS, STALL SHOWERS (WHERE
REQUIRED), SHOWER HEADS, FITTINGS, TRIM. INSTALL LEVER TYPE PLUMBING
FIXTURE HANDLES. BRUSHED CHROME FINISH ACCESSORIES.
14. BATHTUBS TO BE FIBERGLASS PRE-FABRICATED TUB (30" X 60") OR SHOWER
(WHERE REQUIRED), AS INDICATED ON DRAWINGS.
HEATING VENTILATING AND AIR CONDITIONING
1. ALL WORK SHALL BE PERFORMED BY A LICENSED HVAC CONTRACTOR AND
CONFORM TO REQUIREMENTS OF ALL APPLICABLE CODES AND ORDINANCES.
2. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND FILE ALL
NECESSARY DRAWINGS WITH THE CITY AND/OR COUNTY AGENCY HAVING
JURISDICTION.
3. LOCATIONS OF OUTLETS WILL BE COORDINATED WITH LIGHTS AND STRUCTURE ON
THE BASIS OF CURRENT NEC CODES ADOPTED IN NEW MEXICO.
4. PROVIDE PROGRAMMABLE THERMOSTAT.
5. BALANCE SYSTEM AND TEST PERFORMANCE AND OPERATION OF ALL EQUIPMENT
AND MAKE ADJUSTMENTS OR CORRECTIONS REQUIRED FOR PROPER OPERATION.
6. FURNISH AND INSTALL LOW VOLTAGE CONTROL WIRING AND HIGH VOLTAGE
WIRING, INCLUDING CONNECTIONS TO EQUIPMENT.
7. STANDARD ONE (1) YEAR GUARANTEE FOR PARTS AND LABOR. IN ADDITION,
FURNISH A MINIMUM OF FIVE (5) YEAR MANUFACTURER'S WARRANTY FOR
COMPRESSOR, CONDENSER COIL, AND HEAT EXCHANGER.
8. INSULATE RETURN AIR DUCTS WITH SOUND ATTENUATING MATERIAL.
9. REFRIGERANT PIPING TO BE COPPER. PRIMARY CONDENSATE DRAIN TO BE PVC.
RUN TO HUB DRAIN WITH A TRAP PRIMER. AUXILIARY DRAIN PIPING TO BE 1"
PLASTIC. PROVIDE 2" DEEP DRAIN PAN UNDER EQUIPMENT WITH AUTO CUT OFF
FLOAT SWITCH. NOTE THAT MECHANICAL DRAIN LINES CANNOT CONNECT TO
PLUMBING SYSTEM.
10. ALL EQUIPMENT SHALL BE SET ON SUITABLE FOUNDATIONS AND SHALL HAVE
VIBRATION ISOLATION TO PREVENT NOISE. EQUIPMENT INSTALLED OUTSIDE SHALL
BE SET ON PADS AT BASE FLOOD ELEVATION OR IN ACCORDANCE WITH LOCAL
REQUIREMENTS. ALL EQUIPMENT SHALL HAVE MOTOR STARTERS.
11. A COMPLETE CHARGE OF REFRIGERANT AND OIL SHALL BE MAINTAINED
THROUGHOUT THE WARRANTY PERIOD.
12. AFTER THE SYSTEM HAS BEEN COMPLETELY INSTALLED, PROVIDE NECESSARY
TESTING, ADJUSTING, AND OPERATING TO PLACE THE SYSTEM IN SATISFACTORY
OPERATING CONDITION. AFTER FINAL INSPECTION AND APPROVAL, THE SYSTEM
SHALL BE GUARANTEED AGAINST DEFECTIVE WORKMANSHIP AND MATERIALS FOR
A PERIOD OF ONE YEAR.
13. EXTERIOR A/C COMPRESSOR UNIT SHALL BE STRAPPED OR BOLTED TO A
PERMANENT SUPPORT PLATFORM IN ACCORDANCE WITH LOCAL REQUIREMENTS.
14. AIR-CONDITIONING UNITS AND ELECTRIC HEAT PUMP SHALL BE SIZED AND HAVE AN
EFFICIENCY RATING IN ACCORDANCE TO MINIMUM IECC CODE REQUIREMENTS AND
APPROVED ENERGY RATING CALCULATIONS.
15. MECHANICAL VENTILATION NEEDS TO BE PROVIDED, PER IBC 2021 RESIDENTIAL
CODE, CHAPTER 4 VENTILATION, FOR LAUNDRY ROOM OR BATH FAN WITH A
MAKEUP AIR SUPPLY. A CONTROLLED BALANCED MECHANICAL VENTILATION IS
REQUIRED. SEE OPTIONS AS NOTED IN THE 2020 NGBS CERTIFIED SCORING
PATHWAY SECTION 1205.8.
16. THE MINIMUM INSULATION VALUE FOR SUPPLY DUCTWORK IS R-6 IN
SEMI-CONDITIONED SPACE AND R-8 IN UNCONDITIONED SPACE TO COMPLY WITH THE
INTERNATIONAL ENERGY CONSERVATION CODE.
17. DUCT MATERIAL:
a. SUPPLY: FLEX DUCT. MINIMUM R-6 INSULATION WRAP MIN.
b. RETURN: FRAMED PLENUM. FLEX DUCT.
c. REGISTERS: PREFINISHED METAL, OPPOSED BLADE, WHITE.
d. INSULATION: AS REQUIRED BY INTERNATIONAL ENERGY CODE, MOST
RECENT ADOPTED EDITION.
17. ALL HVAC DUCT WORK SHALL BE TAPED AND SEALED WITH MASTIC
18. EXHAUST FAN: PROVIDE EXHAUST FAN/LIGHT COMBINATION ADEQUATE FOR ROOM
SIZE PER MANUFACTURER'S RECOMMENDATION. USE NU-TONE OR EQUAL
SUBSTITUTE APPROVED BY DESIGNER AND MEETING LOCAL REQUIREMENTS. ALL
EXHAUST FANS SHALL HAVE 80 CFM MINIMUM AS REQUIRED BY PROGRAM AND BE
ENERGY STAR RATED. EXHAUST THROUGH ROOF OR SOFFIT EXCEPT ON
TWO-STORY HOUSE EXHAUST THROUGH WALL.
19. MINIMUM MERV 8 FILTERS MUST BE INSTALLED
20. ALL UTILITIES, MACHINERY, AND EQUIPMENT ARE TO BE ELEVATED ABOVE THE
DESIGN FLOOD ELEVATION (DFE) OR DESIGNED AND PROTECTED TO RESIST
DAMAGE BY PREVENTING FLOODWATER FROM ENTERING OR ACCUMULATING
WITHIN THEM IF LOCATED BELOW THE DFE. (ASCE 24-14 CH 7)
21. PLUMBING SYSTEMS BELOW THE DFE SHALL BE DESIGNED WITH AUTOMATIC
BACKFLOW DEVICES (ASCE 24-14 SECTION 7.3.3).
ELECTRICAL
1. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICIAN AND CONFORM TO
REQUIREMENTS OF NATIONAL ELECTRICAL CODES, STATE AND LOCAL CODES AND
ORDINANCES AND ARCHITECTURAL STANDARDS.
2. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND FILE ALL
NECESSARY DRAWINGS WITH THE CITY AND/OR COUNTY AGENCY HAVING
JURISDICTION.
3. CONTRACTOR SHALL SIZE ALL CONDUCTORS, FUSES, AND SWITCHES AS REQUIRED
BY LOADS AND PROVIDE SPACE FOR TWO ADDITIONAL CIRCUITS. LABEL ALL
CIRCUITS IN THE PANEL BOX.
4. ALL 220-VOLT CIRCUITS SHALL BE COPPER. ALL SWITCH LEGS AND 110-VOLT
BRANCH CIRCUITS SHALL BE COPPER, G.E. MULTI-CONDUCTOR, NON-METALLIC
"ROMEX," OR EQUAL. ALL JOINTS SHALL BE CODE APPROVED. CIRCUIT VOLTAGE
DROP SHALL CONFORM TO APPLICABLE CODES.
5. **NO ALUMINUM WIRING SHALL BE USED BEYOND THE PANEL (INTERIOR BRANCH
CIRCUITS OR SWITCH LEGS)**
6. ALUMINUM WIRING MAY ONLY BE USED FROM THE METER TO THE SERVICE PANEL
7. PROVIDE SEPARATE CIRCUITS FOR REFRIGERATOR, DISHWASHER W/ GFCI, RANGE,
AND MICROWAVE OVEN/VENT.
8. PROVIDE MAIN POWER DISCONNECT SWITCH INSTALLED AS REQUIRED BY CODE.
9. PROVIDE INTERIOR BREAKER PANEL ENCLOSURE WITH DOOR AND LATCH AND,
WHERE REQUIRED BY CODE, PROVIDE WITH A MAIN BREAKER. ENCLOSURE SHALL
BE LOCATED 48" ABOVE THE FINISH FLOOR (MAXIMUM) TO THE CENTERLINE OF THE
HIGHEST BREAKER.
10. INSTALL GFCI DEVICE WITHIN 72" OF ANY WATER SOURCE AS SPECIFIED IN
CURRENT IBC, TO INCLUDE DISHWASHER AND WASHER.
11. GFCI RECEPTACLES SHALL BE LABELED IN ACCORDANCE WITH NEC 406.3.
12. ALL SWITCH PLATES ARE TO BE WHITE FACEPLATES, HIGHEST CONTROL NO
HIGHER THAN 48" AFF, EXCEPT AS NOTED IN DOCUMENTS. SWITCH PLATES SHOULD
BE SET AS CLOSE TO DOOR FRAME AS PRACTICAL.
13. ALL CONVENIENCE PLATES ARE TO BE WHITE FACEPLATES, EXCEPT AS NOTED IN
DOCUMENTS.
14. ALL DUPLEX OUTLETS TO BE INSTALLED SUCH THAT THE LOWEST OPERABLE PART
IS NO LOWER THAN 15" AFF, EXCEPT AS NOTED IN DOCUMENTS. COLOR TO MATCH
FACEPLATES.
15. FIXTURES ARE TO BE ENERGY STAR RATED; BRUSHED NICKEL FINISH, UNLESS
NOTED OTHERWISE. REFER TO ELECTRICAL LEGEND FOR REQUIRED FIXTURES
DESCRIPTION. CEILING FANS WITH LIGHT KITS REQUIRED IN BEDROOMS AND LIVING
ROOMS.
16. TYPICAL WALL SWITCH TO BE PROVIDED. COLOR TO MATCH FACEPLATES.
17. FOR TELEVISIONS PROVIDE RG-6 SHIELDED CABLES. PROVIDE FACEPLATE; COLOR
TO MATCH TYPICAL FACEPLATES.
18. FOR TELEPHONES PROVIDE CAT-5 WIRING. PROVIDE FACEPLATE; COLOR TO MATCH
TYPICAL FACEPLATES.
19. PROVIDE SMOKE DETECTOR ALARM WHERE REQUIRED BY CODE. PRODUCT OF
GENTEX # GN-303 SERIES OR OTHER APPROVED. ALARM DEVICES SHALL BE
INTERCONNECTED AND HARDWIRED 120VAC WITH 9VDC OR 10YR BATTERY
BACK-UP AND IN COMPLIANCE WITH UL 217, UL 2034 LISTING AND NFPA 72. DEVICE
SHALL BE INSTALLED PER GOVERNING AUTHORITY BUILDING CODES.
e. NOTE: IF HOUSE IS OCCUPIED BY A PERSON(S) WITH AUDIO/ VISUAL
IMPAIRMENT, PROVIDE SMOKE DETECTOR/ ALARM WITH 90DB HORN AND
FLASHING STROBE LIGHT - GENTEX # 7109-CS-C OR OTHER APPROVED. ALARM
DEVICES SHALL BE INTERCONNECTED AND HARDWIRED 120VAC WITH 9VDC OR
10YR BATTERY BACK-UP AND IN COMPLIANCE WITH UL 217, UL 2034 LISTING.
DEVISE SHALL BE INSTALLED PER GOVERNING AUTHORITY BUILDING CODES
AND NFPA 72.
20. COMBINATION SMOKE DETECTOR / CARBON MONOXIDE DETECTOR ALARM:
PROVIDE WHERE CARBON MONOXIDE DETECTORS ARE REQUIRED BY CODE.
PRODUCT OF GENTEX # GN-503 SERIES OR OTHER APPROVED. ALARM DEVICES
SHALL BE INTERCONNECTED AND HARDWIRED 120VAC WITH 9VDC OR 10YR
BATTERY BACK-UP AND IN COMPLIANCE WITH UL 217, UL 2034 LISTING AND NFPA 72.
DEVICE SHALL BE INSTALLED PER GOVERNING AUTHORITY BUILDING CODES.
21. CONTRACTOR SHALL BE RESPONSIBLE FOR FEES ASSOCIATED WITH
DISCONNECTING AND RECONNECTING UTILITIES. THIS DOES NOT INCLUDE
ACCOUNT SET UP DEPOSIT.
22. 95% HIGH EFFICACY LIGHTING REQUIRED
23. ELECTRIC METERS SHALL BE LOCATED ABOVE THE DESIGN FLOOD ELEVATION
UNLESS THE CONNECTION BETWEEN THE METER AND ELECTRIC LINES EXTENDING
VERTICALLY FROM THE METER IS WITHIN A WATERPROOF ENCLOSURE (ASCE 24-14
SECTION 7.2.3.).
24. MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS AND OTHER SERVICE
EQUIPMENT SHALL BE LOCATED AT OR ABOVE THE REQUIRED FLOOD ELEVATION
REQUIRED IN SECTION R322.2 OR R322.3. OF THE RESIDENTIAL BUILDING CODE.
# DATE DESCRIPTION
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN ANY
FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
ISSUANCE / REVISION
PROJECT LOCATION OR ADDRESS:
CLIENT NAME:
ENGINEERING AND INSPECTIONS, LLC
26-0###
CDBG - DR
NEW MEXICO
G-0.30
AGEING IN PLACE
SWITCH TYP.OUTLETS, DATA, TV,
& TELEPHONE
6' -0
" T
YP
" M
AX
5'-3" MIN.
TUB GRAB BAR
STANDARD
SURFACE MOUNTED
CONTINUOUS TOILET
GRAB BAR, SURFACE
MOUNTED w/ SNAP FLANGE
TO BOTTOM OF
REFLECTIVE
SURFACE
2' -9
'-0
3'-0"
MAX
6'-9" MIN.
TOILET TISSUE
DISPENSER,
SINGLE - SURF- MTD.
1'-6"
MAX
24"
MIN.
1' -1
/2
LINE OF
WALL
1' -1
1/
2"
4'-6" MIN.
2'
-9 " M
IN
3'
-0 " M
AX
3' -4
" M
AX
4' -6
M
AX
.7'
-0
2' -3
BLOCKING,
TYP.
ROLL-IN SHOWER GRAB
BARS, SURFACE MOUNTED
LINE
OF
WALL
24"
2' -1
0"
3' -0
LINE OF
WALL
2' -1
0"
3' -0
3'-4 1/2"
MAX
2' -1
0"
3' -0
1'-6"
2' -1
0"
3' -0
1'-6"
MAX
SINK
4' -0
" A C
C
ES
SI
BL
E 5'
-0 " T
YP
IC
AL
6"
MAX.
TOILET
16"-18"
NOTE:
ADA-TOILETS SHALL HAVE A TOILET SEAT
17"-19" AFF-AND SHALL HAVE CONTROL
VALVES ON THE WIDE SIDE OF THE TOILET
TANK, OPPOSITE OF ADJACENT WALL.
LINE OF
WALL
5' -3
1' -1
1/
2"
3'-9"
NAPKIN DISPOSAL
4 1/2"
LIGHT SWITCH
AT DOOR, TYP.
LINE OF
WALL
9" OF
BOWL
7' -9
" A C
C
ES
SI
BL
E
LINE OF
WALL
BEYOND
9"
CORNER
WALL
9"
6' -0
SINKTOILET & URINAL
LOCATION
OF
CONTROLS
3" -6
2'
-3
M
IN
CONTROL
WALL3'
-3
'-5
4' -9
" M
IN
6' -0
" M
AX
9"
MAX
LOCATION
OF CONTROL
LINE OF
WALL
LINE OF
WALL
BEYOND
FOLDING SHOWER
SEAT, SURFACE
MOUNTED
2'-6"
ACCESSIBLE TUB GRAB BARS
ACCESSIBLE ROLL-IN SHOWER GRAB BARS & SEAT
ACCESSORIES
7' -0
REMOVABLE
SEAT
7' -0
" S
TA
N D
AR
D
WHEN ABOVE
LOWER OUTLET
7' -0
9"
MAX
LINE OF
WALL
BEYOND
LINE OF
WALL
LINE OF
WALL
BEYOND
9'-0" 3'-9"
4' -0
" A D
A
7"-9"
ADJUSTABLE HEIGHT HAND
SHOWER MOUNTED ON
VERTICAL BAR
NOTE:
MATERIALS USED AS BACKERS FOR WALL TILE
IN TUB AND SHOWER AREAS AND WALL
PANELS IN SHOWER AREAS SHALL BE OF
MATERIALS LISTED IN TABLE R702.4.2.
*WHEN REQUIRED BY DISASTER RECOVERY PROGRAM, AND/OR MUNICIPAL CODE, AND/OR BUILDING CODE.
ADJUSTABLE HEIGHT
HAND SHOWER MOUNTED
ON VERTICAL BAR
LINE OF
WALL
BEYOND
TOWEL
BAR, SURFACE
MOUNTED
SHOWER CURTAIN
ROD MOUNTING
HEIGHT, TYP.
STANDARD
SHOWER HEAD
MOUNTING HEIGHT
STANDARD
CONTROLS
MOUNTING HEIGHT
WIRE CORNER
CADDY
(TUB & SHOWER)
WALL
MOUNTED
CORRIDOR SCONCE
WALL
MOUNTED
HAIRDRYER
MIRROR SURFACE
MOUNTED AT PUBLIC
& BOH TOILET
SE
E
N O
TE
TOILET
ACCESSORIES
FRONT VIEW SIDE VIEW FRONT/SIDE VIEW CONTROL WALL VIEW BACK WALL VIEW HEAD WALL VIEW
CONTROL WALL VIEW SIDE VIEW
1' -0
2' -0
# DATE DESCRIPTION
NOTE: SIGNATURES VALID FOR ONE YEAR ONLY AFTER DATE OF SIGNATURES
ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN ANY
FORM WITHOUT PRIOR WRITTEN AUTHORIZATION OF “COBALT”.
ISSUANCE / REVISION
PROJECT LOCATION OR ADDRESS:
CLIENT NAME:
ENGINEERING AND INSPECTIONS, LLC
26-0###
CDBG - DR
NEW MEXICO
01 ROOF PLAN 02 FLOOR PLAN
SCALE SCALE
SQUARE FOOTAGE CALCULATIONS
LOCATION SQUARE FOOTAGE REMARKS
FLOOR PLAN 1,478 SQFT
FRONT PORCH 92 SQFT
SIDE PORCH 45 SQFT
DOOR SCHEDULE
MARK QTY DESCRIPTIONS REMARKS
01 1 3'-0" X 6'-8" 1/2 LITE EXTERIOR
02 1 3'-0" X 6'-8" EXTERIOR
03 6 3'-0" X 6'-8" INTERIOR
04 1 2'-0" X 6'-8" INTERIOR
05 1 (2) 2'-0" X 6'-8" DOUBLE DOOR
06 1 22" X 30" MIN. ATTIC ACCESS 250 POUND LADDER RATING
07 1 3'-0" X 6'-8"
SELF CLOSING WITH A
MINIMUM OF 20 MINUTE FIRE
RATING (VENTED)
08 1 (2) 2'-6" X 6'-8" VENTED (IF GAS
APPLIANCES)
09 1 2'-0" X 6'-8"
VENTED (IF GAS
APPLIANCES)
WINDOW SCHEDULE
MARK QUANTITY DESCRIPTIONS REMARKS
A 7 3'-0" X 5'-0" SINGLE HUNG
B 1 3'-0" X 3'-0" SINGLE HUNG
MASTER
BATH
78 S.F.
9'-0" CLG.
A
A
A
BEDROOM 2
107 S.F.
9'-0" CLG.
LIVING/DI…