6-SLCC RM 020 090 BID SET DRAWINGS 01-12-2026.pdf

PDF 17 MB Posted

Attached to
SLCC CT Classroom Remodel 020 090
Solicitation number
SLCC2026-W1014
Issued by
Salt Lake County, Salt Lake City, Utah

About this file

This is a Bid Set Drawing package for an interior tenant improvement project at Salt Lake Community College (SLCC) located at 1830 Community Boulevard, Taylorsville, Utah 84123. The project involves the remodeling of Rooms 020 and 090, which will function as classroom and testing center spaces. The scope of work includes selective demolition of existing walls, ceilings, flooring, and mechanical/electrical/plumbing systems; installation of new gypsum board assemblies, acoustical ceilings, resilient flooring, carpet tiles, and interior painting; reconfiguration of mechanical HVAC systems with VAV boxes and ductwork modifications; electrical system upgrades including new lighting fixtures, receptacles, wiring, and fire alarm devices; and restoration of finishes and systems to code-compliant conditions. The project documents indicate separate cost line items must be provided for work in Rooms 020 and 090. The drawings are dated January 12, 2026, with a revision response to comments dated January 7, 2026. The contract is structured as a stipulated sum (single prime contract) with the tenant providing builder's risk insurance and the general contractor demonstrating comprehensive liability and automobile liability coverage.

The project specifications require compliance with 2021 International Building Code, 2021 International Mechanical Code, 2021 International Plumbing Code, 2021 International Fire Code, 2021 International Electrical Code, and 2023 National Electrical Code standards. Deferred submittals are required for fire alarm and fire sprinkler systems, with final design and specifications to be provided by the contractor. The project includes allowances for spare ceiling tiles (20 tiles for Room 020 and 40 tiles for Room 090) and requires coordination with the building owner for contractor staging areas, delivery entrances, and parking. Final completion requirements include code inspection reports, fire marshal clearance, elevator and boiler inspector approvals where applicable, and certificates of compliance from fabricators. The documents note that the owner will furnish and install certain items such as whiteboards and signage, while the contractor is responsible for receiving, handling, storage, installation, and protection of owner-furnished materials.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DFCM SUBMITTAL NOTES

1. A CODE INSPECTION REPORT RECOMMENDING THAT A CERTIFICATE OF OCCUPANCY BE ISSUED.

2. CERTIFICATE OF FIRE CLEARANCE FROM THE SLCC FIRE MARSHALL.

3. FINAL APPROVAL FROM THE STATE ELEVATOR INSPECTOR, IF APPLICABLE.

4. FINAL APPROVAL FROM THE STATE BOILER INSPECTOR, IF APPLICABLE.

5. A CERTIFICATE OF COMPLIANCE FROM THE APPROVED FABRICATOR, IF APPLICABLE. IBC 1704.2.2

North: ______ South: ______ East: ______ West: ______

Special Use and Occupancy (e.g. High Rise, Covered Mall): __________________

Official for Complex Buildings. Including, but not limited to:

g) Fire Stopping, Including Tested Design Number.

f) Exterior and Interior Accessibility Route.

e) Fire Assembly Locator Sheet.

a) High Rise Requirements.

b) Atriums.

c) Performance Based Criteria.

d) Means or Egress Analysis.

2) Additional Code Information shall be provided at the discretion of the Building

Code Accessibility Chapters, the more restrictive requirement shall govern.

through - ADA Guidelines and specific reference to the International Building

1) In case of conflict with the U.S. Department of Justice Federal Registers Parts

FOOTNOTES:

M. Minimum Number of Required Plumbing Facilities:

FIXTURES REQUIRED & PROVIDED UNCHANGED BY REMODEL.

Exit Width Required: _______________ Exit Width Provided: _______________

Element Hours Assembly ListingListingElement AssemblyHours

Smoke Partitions Fire Partitions

Exterior Bearing Walls Interior Bearing Walls Exterior Non-Bearing Walls Structural Frame Partitions - Permanent Fire Barriers

Floors - Ceiling Floors Roofs - Ceiling Roofs Exterior Doors and Windows Shaft Enclosures Fire Walls

BAHTBABABA

Design Wind Speed: ______ mphB. Seismic Design Category: ______

L. Design Occupant Load: ____________

K. Fire Resistance Rating Requirements for Building Elements (hours).

Area Modifications:J:

____________________________________________Tabular Area:I:

per Floor (square feet): Actual AreaH:

Number of Stories: ______ Building Height: _____________G:

Required: ______ Provided: ______ Type of Sprinkler System: ____________ Sprinklers:F:

Mixed Occupancies: ______ Nonseparated Uses: ______E.

separation distance (in hours):

Requirements for the Exterior Walls based on the fireFire Resistance RatingD.

C. Type of Construction (circle one):

Change in Use: Yes ______ No ______ Mixed Occupancy: Yes _____ No ______

Guildelines ADA Accessibility Building Conservation Uniform Code for National Electrical Code

Conservation Code International Energy International Fire Code International Plumbing Code International Mechanical Code International Building Code

YearYear

APPLICABLE CODES

A. Occupancy and Group: ________ ________ ________ ________ ________

CODE ANALYSIS

B

XX

TBD N/A

N/A N/A N/A N/A

UNCHANGED

L1= UNCHANGED

N/A N/A N/A N/A

UNCHANGED

UNCHANGED

UNCHANGED

UNCHANGED

UNCHANGED

NOT APPLICABLE

3 UNCHANGED

N/A0

92,000 SQFT PER FLOOR

L2= UNCHANGED

Basement= UNCHANGED

NOT APPLICABLE

Total= UNCHANGED

Stair Width Required: ____________ Stair Width Provided: ____________

N/A

1. DEFERRED SUBMITTALS WILL INCLUDE FIRE ALARMS AND FIRE SPRINKLERS.

Gas Code International Fuel ICC-A117.1

Accessibility Standard

Stair Occupant Load: _____________UNCHANGED

REQUIREMENTS FOR OCCUPANCY

EXIST.

PROJECT DIRECTORY

ARCHITECT

CRSA

STEVE SIMMONS

(801) 355-5915

STEVE@CRSA.COM

MECHANICAL ENGINEER

RESOLUT GROUP

JAKE BECK

(801) 530-3148

JBECK@RESOLUTGROUP.COM

ELECTRICAL ENGINEER

MATTHEW HARVERKAMP

SPECTRUM ENGINEERING

(800) 678-7077

MATT.HAVERKAMP@SPECENG.COM

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

1/ 7/

1:

:1

AM GI000

COVER SHEET

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

NONSTRUCTURAL COMPONENT CHECKLIST

ITEM DESCRIPTION

NOT

REQUIRED

ON CONST.

DOCUMENTS

DEFERRED

SUBMITTAL COMMENTS

ARCHITECTURAL COMPONENTS:

Interior Nonstructural Walls & Partitions X Cantilever Elements (i.e. parapets, etc.) X Exterior Nonstructural Wall Elements X Veneer X Penthouse X Ceilings (i.e. suspended grid or hard-lid) X Cabinets (i.e. storage cabinets, equip, etc.) X Access Floors X Storage Racks X Appendages & Ornamentations X Signs & Billboards X Others:

Others: X

MEP COMPONENTS: X

Fire Sprinklers X Mechanical Equipments (i.e. HVAC, fans, air handlers, boilers, furnaces, tanks, chillers, water heaters, heat exchangers, evaporates, engines, turbines, pumps, compressors, MFR equipments, etc.)

X Mechanical Submittal

Electrical Equipments (i.e. generators, batteries inverters, transformers, MCC, panel boards, switch gear, cabinets, etc.)

X Electrical Submittal

Elevator & Escalator Components X Communication Equipments, Computers, Instrumentation, and Controls X Roof - mounted Chimneys, Stacks, Cooling & Electrical Towers X Lighting Fixtures X Vibration Isolated Components X Piping & Conduit System X Mechanical & Electrical Submittal Ductwork (including in-line components) X Mechanical Submittal Conveyors X Cable Trays X Electrical Submittal Others: X Others: X

SHEET INDEX

GENERAL INFORMATION

GI000 COVER SHEET

GI001 LEVEL 0 LIFE SAFETY PLAN

GI002 LEVEL 1 LIFE SAFETY PLAN

GI003 ARCHITECTURAL SPECIFICATIONS

GI004 SYMBOLS AND LEGENDS

ARCHITECTURE

AD100 LEVEL 0 RM 020 DEMO FLOOR & RCP PLAN

AD101 LEVEL 0 RM 090 DEMO FLOOR & RCP PLAN

AE100 LEVEL 0 RM 090 FLOOR, FINISH & RCP PLANS

AE101 LEVEL 0 RM 020 FLOOR, FINISH & RCP PLANS

AE501 WALLS, DOOR TYPES, SCHEDULES & DETAILS

MECHANICAL

M000 MECHANICAL SYMBOLS AND LEGEND

M001 MECHANICAL GENERA NOTES

M100 LEVEL 0 MECHANICAL PLAN

M401 ENLARGED MECHANICAL PLANS

M402 ENLARGED MECHANICAL PLANS

M501 MECHANICAL DETAILS & SCHEDULES

M701 MECHANICAL SPECIFICATIONS

M702 MECHANICAL SPECIFICATIONS

ELECTRICAL

EE001 ELECTRICAL COVER SHEET

EE002 ELECTRICAL SPECIFICATIONS

EE003 ELECTRICAL SPECIFICATIONS

EE004 TELECOM SCHEDULES AND NOTES

EE501 ELECTRICAL DETAILS

EE701 TYPICAL MOUNTING DETAILS

ED100 OVERALL ELECTRICAL DEMOLITION PLAN

ED101 RM 090 ELECTRICAL DEMOLITION PLAN

ED102 RM 020 ELECTRICAL DEMOLITION PLAN

EP100 OVERALL ELECTRICAL PLAN

EP101 ROOM 090 ENLARGED ELECTRICAL PLAN

EP102 ROOM 020 ENLARGED ELECTRICAL PLAN

EP601 ELECTRICAL SCHEDULES

EP615 PANEL SCHEDULES

EY601 FIRE ALARM RISER DIAGRAMS

SLCC RM 020 & 090 REMODEL

1830 COMMUNITY BLVD

TAYLORSVILLE, UT 84123

NOTES TO BIDDERS:

PROVIDE SEPARATE COSTS IN THE BID FOR WORK IN ROOMS 020 & 090

NO. DATE DESCRIPTION

1 2026/01/07 RESPONSE TO

COMMENTS

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

GRW

Call 801-403-8152 for Inspections

Haverkamp

10221159-2202 Matthew John

L

IC

EN

S E

D

PROF E S S I ONA L

ENG

I NEER

S T A T E O F U T A H

No.

11/21/2025

L I C

E N

S E

D

P

ROFESS IONA

L

E N

G I N

E E

R

No. 8325442-2202

S

T A

T E OF U

TA

H

JACOB D.

BECK

12-19-25

CLASSROOM

090C

CLASSROOM

WOMEN RR

MEN RR

082A

STORAGE

001C

HALLWAY

001B

HALLWAY

090B

STORAGE

S005

STAIRS

TESTING

CENTER

001A

HALLWAY

033B-A

TESTING LAB

HALLWAY

033D

IT OFFICE

033E

DOUBLE

OFFICE

033F

WORKROOM

033B

OBSERVATION

033A

GED TESTING

RECEPTION

033G

DIRECTOR

OFFICE

033H

ADVISOR

OFFICE

63' - 4" 232' - 3"

67' - 8" 214' - 5"

71' - 1" 165' - 9"

69' - 11" 82' - 7"

71' - 1" 215' - 2"

S001

STAIRS

CLASSROOM

FILE SECURE

STORAGE

001F

HALLWAY

EXIT

LIFE SAFETY LEGEND

EXIT ACCESS PATH

EXIT SIGN

EGRESS PATH

TRAVEL DISTANCE

30' - 0" 50' - 0"

COMMON PATH

OF TRAVEL

ACCESSORY STORAGE AREAS, MECHANICAL

EQUIPMENT ROOM

EDUCATIONAL

BUSINESS AREAS

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/2

2/

:2 6:

P

M GI001

LEVEL 0 LIFE

SAFETY PLAN

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

3/32" = 1'-0"GI001

A1 LEVEL 0 LIFE SAFETY PLAN

N

OCCUPANT LOAD BY ROOM

MARK ROOM NAME AREA ROOM FUNCTION OCCUPANT LOAD FACTOR OCCUPANTS EXIT WIDTH TOTAL

020 TESTING CENTER 884 SF EDUCATIONAL - CLASSROOM AREA (20 SF NET) 20 45 9.00"

033 HALLWAY 415 SF BUSINESS AREAS (100 SF GROSS) 100 5 1.00"

033 RECEPTION 250 SF BUSINESS AREAS (100 SF GROSS) 100 3 0.60"

033A GED TESTING 704 SF BUSINESS AREAS (100 SF GROSS) 100 8 1.60"

033B OBSERVATION 136 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"

033B-A TESTING LAB 559 SF BUSINESS AREAS (100 SF GROSS) 100 6 1.20"

033D IT OFFICE 119 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"

033E DOUBLE OFFICE 177 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"

033F WORKROOM 73 SF BUSINESS AREAS (100 SF GROSS) 100 1 0.20"

033G DIRECTOR OFFICE 124 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"

033H ADVISOR OFFICE 100 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"

090 CLASSROOM 955 SF EDUCATIONAL - CLASSROOM AREA (20 SF NET) 20 48 9.60"

090B STORAGE 149 SF ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM (300 SF GROSS) 300 1 0.20"

090C CLASSROOM 974 SF EDUCATIONAL - CLASSROOM AREA (20 SF NET) 20 49 9.80"

TOTAL OCCUPANT LOAD (PER

LEVEL) 5620 SF 176 35.20"

NO. DATE DESCRIPTION

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

GRW

Call 801-403-8152 for Inspections

LIFE SAFETY LEGEND

EXIT ACCESS PATH

EXIT SIGN

EGRESS PATH

TRAVEL DISTANCE

30' - 0" 50' - 0"

COMMON PATH

OF TRAVEL

ACCESSORY STORAGE AREAS, MECHANICAL

EQUIPMENT ROOM

EDUCATIONAL

BUSINESS AREASEXIT

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/2

2/

:2 6:

P

M GI002

LEVEL 1 LIFE

SAFETY PLAN

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

N

3/32" = 1'-0"GI002

A1 LEVEL 1 LIFE SAFETY PLAN

NO. DATE DESCRIPTION

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/2

2/

:2 6:

P

M GI003

ARCHITECTURAL

SPECIFICATIONS

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

SECTION 011000 - SUMMARY

1.1 PROJECT

PROJECT NAME: SLCC RM 020 & 090 REMODEL

OWNER: SALT LAKE COMMUNITY COLLEGE

ARCHITECT: CRSA

1.2 CONTRACT DESCRIPTION

A. STIPULATED SUM (SINGLE PRIME CONTRACT)

1.3 SUPPLEMENTARY CONDITIONS

A. INSURANCE REQUIREMENTS

1. THE TENANT SHALL PROVIDE BUILDER’S RISK INSURANCE DURING CONSTRUCTION AND PROPERTY AND LIABILITY INSURANCE FOR

COMPLETED IMPROVEMENTS.

2. THE TENANT’S GENERAL CONTRACTOR MUST DEMONSTRATE A CERTIFICATE OF INSURANCE LICENSED IN THE STATE OF UTAH SHOWING FULL COVERAGE OF THE CONTRACTOR FOR COMPREHENSIVE AUTOMOBILE LIABILITY AND COMMERCIAL GENERAL LIABILITY.

1.4 SCOPE OF WORK

A. SCOPE OF WORK OF PROJECT: INTERIOR TENANT IMPROVEMENT WITHIN AN EXISTING BUILDING AS INDICATED IN THE CONTRACT DOCUMENTS.

B. USE OF SITE: LIMITED TO WORK IN AREAS INDICATED. COORDINATE WITH BUILDING OWNER FOR CONTRACTOR STAGING AREAS, CONTRACTOR

DELIVERY ENTRANCES AND CONTRACTOR PARKING AREAS.

C. TENANT'S OCCUPANCY REQUIREMENTS: OCCUPANCY OF COMPLETED AREAS OF CONSTRUCTION.

D. FOR FF&E (FIXTURES, FURNITURE AND EQUIPMENT) SEE INFORMATION THAT IS PROVIDED BY THE DESIGN AGENCY

END OF SECTION 011000

SECTION 012500 - SUBSTITUTION PROCEDURES

1.1 SECTION INCLUDES

A. PROCEDURAL REQUIREMENTS FOR PROPOSED SUBSTITUTIONS.

1.2 GENERAL REQUIREMENTS

A. SUBSTITUTION REQUEST FORM: CSI FORM13.1A.

B. DOCUMENTATION:

1. JUSTIFICATION.

2. COORDINATION INFORMATION.

3. DETAILED COMPARISON.

4. PRODUCT DATA.

5. SAMPLES.

6. CERTIFICATES AND QUALIFICATION DATA.

7. LIST OF SIMILAR INSTALLATIONS.

8. MATERIAL TEST REPORTS.

9. RESEARCH REPORTS.

10. DETAILED COMPARISON OF CONTRACTOR'S CONSTRUCTION SCHEDULE.

11. COST INFORMATION.

12. CONTRACTOR'S CERTIFICATION.

13. CONTRACTOR'S WAIVER OF RIGHTS TO ADDITIONAL PAYMENT OR TIME.

C. ARCHITECT'S ACTION: IF NECESSARY, ARCHITECT WILL REQUEST ADDITIONAL INFORMATION WITHIN SEVEN DAYS OF RECEIPT OF A REQUEST FOR SUBSTITUTION. ARCHITECT WILL NOTIFY CONTRACTOR OF ACCEPTANCE OR REJECTION WITHIN 15 DAYS OF RECEIPT, OR

SEVEN DAYS OF RECEIPT OF ADDITIONAL INFORMATION.

1.3 SUBSTITUTIONS

A. SUBSTITUTIONS FOR CAUSE: NOT LATER THAN 15 DAYS PRIOR TO TIME REQUIRED FOR PREPARATION AND REVIEW OF SUBMITTALS.

B. SUBSTITUTIONS FOR CONVENIENCE: WILL BE CONSIDERED IF RECEIVED WITHIN 30 DAYS AFTER COMMENCEMENT OF THE WORK.

END OF SECTION 012500

SECTION 012900 - PAYMENT PROCEDURES

1.1 SUMMARY

A. SCHEDULE OF VALUES:

1. PROVIDE MULTIPLE LINE ITEMS FOR PRINCIPAL SUBCONTRACT AMOUNTS IN EXCESS OF FIVE PERCENT OF THE CONTRACT SUM.

2. INCLUDE SEPARATE LINE ITEMS UNDER CONTRACTOR AND PRINCIPAL SUBCONTRACTS FOR PROJECT CLOSEOUT REQUIREMENTS IN AN

AMOUNT TOTALING FIVE PERCENT OF THE CONTRACT SUM AND SUBCONTRACT AMOUNT.

3. UTILIZE DFCM FORM "SCHEDULE OF VALUES".

B. APPLICATIONS FOR PAYMENT:

1. PAYMENT APPLICATION TIMES: INDICATED IN THE AGREEMENT.

2. PAYMENT APPLICATION FORMS: AIA DOCUMENT G702 AND AIA DOCUMENT G703.

3. WAIVER OF MECHANIC'S LIEN: SUBMITTED FROM ENTITIES LAWFULLY ENTITLED TO FILE A LIEN FOR WORK COVERED BY PAYMENT INCLUDING

SUBCONTRACTORS, SUB-SUBCONTRACTORS, AND SUPPLIERS FOR CONSTRUCTION PERIOD COVERED BY PREVIOUS APPLICATION.

END OF SECTION 012900

SECTION 013100 - PROJECT MANAGEMENT AND COORDINATION

1.1 REQUESTS FOR INFORMATION (RFIS)

A. RFI FORMS: USE AIADOCUMENTG716.

B. ARCHITECT'S ACTION: ALLOW SEVEN WORKING DAYS FOR ARCHITECT'S RESPONSE FOR EACH RFI.

C. RFI LOG: MAINTAIN A TABULAR LOG OF RFIS. SUBMIT LOG WEEKLY. USE CSI LOGFORM13.2B.

1.2 PROJECT MEETINGS

A. SCHEDULE AND CONDUCT MEETINGS.

B. PRE-CONSTRUCTION CONFERENCE.

1. PRE-INSTALLATION CONFERENCES: BEFORE EACH CONSTRUCTION ACTIVITY THAT REQUIRES COORDINATION.

C. PROJECT CLOSEOUT CONFERENCE: NO LATER THAN 30 DAYS PRIOR TO THE SCHEDULED DATE OF SUBSTANTIAL COMPLETION.

D. PROGRESS MEETINGS: AT WEEKLY, COORDINATED WITH PREPARATION OF PAYMENT REQUESTS.

E. COORDINATION MEETINGS: AT BIWEEKLY INTERVALS, IN ADDITION TO SPECIFIC MEETINGS HELD FOR OTHER PURPOSES.

END OF SECTION 013100

SECTION 013200 - CONSTRUCTION PROGRESS DOCUMENTATION

1.1 INFORMATIONAL SUBMITTALS

A. FORMAT FOR SUBMITTALS: PDF ELECTRONIC FILE.

B. CONTRACTOR'S CONSTRUCTION SCHEDULE.

C. SPECIAL REPORTS: SUBMIT AT TIME OF UNUSUAL EVENT.

D. UPDATING: AT MONTHLY INTERVALS, ISSUED ONE WEEK BEFORE PROGRESS MEETING.

END OF SECTION 013200

SECTION 013300 - SUBMITTAL PROCEDURES

1.1 PROCEDURES

A. ELECTRONIC COPIES OF DIGITAL DATA FILES OF THE CONTRACT DRAWINGS WILL BE PROVIDED BY ARCHITECT FOR CONTRACTOR'S USE, IF ASKED.

B. PROCESSING TIME:

1. INITIAL REVIEW: 14 DAYS.

2. RE-SUBMITTAL REVIEW: 15 DAYS.

3. CONCURRENT CONSULTANT REVIEW: 14 DAYS.

C. TRANSMITTAL FORM: AIA DOCUMENT G810.

D. SUBMITTAL PROCEDURES:

1. POST PDF FILES DIRECTLY TO ARCHITECT'S FTP SITE.

A. ACTION SUBMITTALS.

B. INFORMATIONAL SUBMITTALS.

C. CERTIFICATES AND CERTIFICATIONS SUBMITTALS: PROVIDE A DIGITAL SIGNATURE ON ELECTRONICALLY SUBMITTED

CERTIFICATES AND CERTIFICATIONS WHERE INDICATED.

D. DELEGATED-DESIGN SERVICES CERTIFICATION: IN ADDITION TO OTHER REQUIRED SUBMITTALS, SUBMIT DIGITALLY SIGNED PDF

ELECTRONIC FILE, SIGNED AND SEALED BY THE RESPONSIBLE DESIGN PROFESSIONAL.

E. CONTRACTOR'S REVIEW:

1. SUBMITTALS: MARKED WITH APPROVAL STAMP BEFORE SUBMITTING TO ARCHITECT.

2. ACTION SUBMITTALS: STAMPED WITH AN ACTION STAMP AND RETURNED.

3. INFORMATIONAL SUBMITTALS: REVIEWED BUT NOT RETURNED, OR REJECTED IF THEY DO NOT COMPLY WITH REQUIREMENTS.

4. INCOMPLETE SUBMITTALS WILL BE RETURNED WITHOUT REVIEW.

5. SUBMITTALS NOT REQUIRED: MAY NOT BE REVIEWED AND MAY BE DISCARDED.

END OF SECTION 01300

SECTION 015000 - TEMPORARY FACILITIES AND CONTROL

1.1 GENERAL

A. FIRE EXTINGUISHERS.

1.2 TEMPORARY UTILITY INSTALLATION

A. PROVIDE ISOLATION OF WORK AREAS IN OCCUPIED FACILITIES WITH NOISE AND DUST CONTROLS.

END OF SECTION 015000

SECTION 015000 - PRODUCT REQUIREMENTS

1.1 PRODUCT SELECTION PROCEDURES

A. PRODUCT SELECTION PROCEDURES:

1. MANUFACTURER/SOURCE: PRODUCT BY MANUFACTURER OR FROM SOURCE NAMED THAT COMPLIES WITH REQUIREMENTS.

2. PRODUCTS: ONE OF THE PRODUCTS LISTED THAT COMPLIES WITH REQUIREMENTS. COMPARABLE PRODUCTS WILL BE CONSIDERED

UNLESS OTHERWISE INDICATED.

3. MANUFACTURERS: PRODUCT BY ONE OF THE MANUFACTURERS LISTED THAT COMPLIES WITH REQUIREMENTS. COMPARABLE

PRODUCTS WILL BE CONSIDERED UNLESS OTHERWISE INDICATED.

4. BASIS-OF-DESIGN PRODUCT: EITHER THE SPECIFIED PRODUCT OR A COMPARABLE PRODUCT BY ONE OF THE OTHER NAMED

MANUFACTURERS.

5. VISUAL MATCHING SPECIFICATION: PRODUCT THAT MATCHES ARCHITECT'S SAMPLE. ARCHITECT'S DECISION WILL BE FINAL.

6. VISUAL SELECTION SPECIFICATION: PRODUCT (AND MANUFACTURER) THAT COMPLIES WITH OTHER SPECIFIED REQUIREMENTS.

ARCHITECT WILL SELECT COLOR, GLOSS,PATTERN, DENSITY, OR TEXTURE FROM MANUFACTURER'S PRODUCT LINE THAT INCLUDES

BOTH STANDARD AND PREMIUM ITEMS.

B. COMPARABLE PRODUCTS

1. CONDITIONS FOR CONSIDERATION:

A. PRODUCT DOES NOT REQUIRE REVISIONS TO THE CONTRACT DOCUMENTS, IS CONSISTENT WITH THE CONTRACT DOCUMENTS AND WILL PRODUCE THE INDICATED RESULTS, AND IS COMPATIBLE WITH OTHER PORTIONS OF THE WORK.

B. COMPARISON OF PROPOSED PRODUCT WITH THOSE NAMED IN THE SPECIFICATIONS.

C. PRODUCT PROVIDES SPECIFIED WARRANTY.

END OF SECTION 016000

SECTION 017300 - EXECUTION

1.1 EXECUTION

A. EXISTING CONDITIONS: EXISTENCE AND LOCATION OF SITE IMPROVEMENTS, UTILITIES, AND OTHER CONSTRUCTION AFFECTING

THE WORK MUST BE INVESTIGATED AND VERIFIED.

1. REVIEW OF THE CONTRACT DOCUMENTS AND FIELD CONDITIONS.

C. PROGRESS CLEANING

1. CLEAN PROJECT SITE AND WORK AREAS DAILY. DISPOSE OF MATERIALS LAWFULLY.

2. KEEP INSTALLED WORK CLEAN.

3. REMOVE DEBRIS FROM CONCEALED SPACES.

D. STARTING AND ADJUSTING

1. START EQUIPMENT AND OPERATING COMPONENTS TO CONFIRM PROPER OPERATION.

2. ADJUST EQUIPMENT FOR PROPER OPERATION.

E. PROTECTION OF INSTALLED CONSTRUCTION

1. PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS THAT ENSURE WORK IS WITHOUT DAMAGE.

END OF SECTION 017300

SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL

1.1 SUMMARY

A. RECYCLING NONHAZARDOUS DEMOLITION AND CONSTRUCTION WASTE, TO GREATEST EXTENT PRACTICAL.

B. DISPOSING OF NONHAZARDOUS DEMOLITION AND CONSTRUCTION WASTE.

1.2 WASTE MANAGEMENT PLAN

A. TYPES AND QUANTITIES OF DEMOLITION AND CONSTRUCTION WASTE.

B. TRAIN WORKERS, SUBCONTRACTORS, AND SUPPLIERS ON PROPER WASTE MANAGEMENT PROCEDURES.

C. CONTRACTOR TO TEST EXISTING DOORS FOR ASBESTOS. IF ASBESTOS IS DETECTED, SLCC WILL BE RESPONSIBLE FOR THE REMOVAL AND

DISPOSAL OF THE DOOR.

END OF SECTION 017419

SECTION 017700 - CLOSEOUT PROCEDURES

1.1 SUBSTANTIAL COMPLETION

A. PREPARE AND SUBMIT CONTRACTOR'S LIST OF INCOMPLETE ITEMS (PUNCH LIST) PREPARED ON CSI FORM14.1A.

B. OWNER ADVISED OF PENDING INSURANCE CHANGEOVER.

C. WARRANTIES, MAINTENANCE SERVICE AGREEMENTS, AND SIMILAR DOCUMENTS SUBMITTED.

D. RELEASES, OCCUPANCY PERMITS, AND OPERATING CERTIFICATES SUBMITTED.

E. PROJECT RECORD DOCUMENTS SUBMITTED.

F. TOOLS, SPARE PARTS, AND EXTRA MATERIALS DELIVERED.

G. FINAL CHANGEOVER OF LOCKS PERFORMED.

H. STARTUP TESTING COMPLETED.

I. TEST/ADJUST/BALANCE RECORDS SUBMITTED.

J. TEMPORARY FACILITIES REMOVED.

K. OWNER ADVISED OF HEAT AND UTILITY CHANGEOVER.

L. CHANGEOVER INFORMATION FOR USE, OPERATION, AND MAINTENANCE SUBMITTED.

M. OWNER'S PERSONNEL INSTRUCTED IN OPERATION, ADJUSTMENT, AND MAINTENANCE OF EQUIPMENT AND SYSTEMS.

N. FINAL CLEANING PERFORMED.

O. TOUCH-UP PERFORMED.

P. 10% FINISH MATERIALS MUST BE RESERVED FOR ATTIC STOCK.

1.2 FINAL COMPLETION

A. PRELIMINARY PROCEDURES: BEFORE REQUESTING FINAL INSPECTION, COMPLETE THE FOLLOWING:

B. FINAL APPLICATION FOR PAYMENT SUBMITTED.

C. LIST OF INCOMPLETE ITEMS (PUNCH LIST) ENDORSED BY ARCHITECT AS COMPLETED OR OTHERWISE RESOLVED FOR ACCEPTANCE.

D. EVIDENCE OF CONTINUING INSURANCE COVERAGE SUBMITTED.

E. FINAL PEST-CONTROL INSPECTION REPORT AND WARRANTY SUBMITTED.

1.3 SUBMITTAL OF PROJECT WARRANTIES.

A. PARTIAL OCCUPANCY: SUBMIT WARRANTIES WITHIN 15 DAYS OF COMPLETION OF DESIGNATED PORTIONS OF THE WORK THAT ARE OCCUPIED

OR USED BY OWNER.

B. ORGANIZE WARRANTY DOCUMENTS BASED ON PROJECT MANUAL AND BIND IN HEAVY-DUTY, THREE-RING, VINYL-COVERED, LOOSE-LEAF

BINDERS.

C. SCAN WARRANTIES AND BONDS INTO A SINGLE INDEXED ELECTRONIC PDF FILE.

1.4 O AND M MANUALS.

1.5 FINAL CLEANING

A. CLEAN EACH SURFACE OR UNIT TO CONDITION EXPECTED IN AN AVERAGE COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM.

B. REPLACE DISPOSABLE AIR FILTERS AND CLEAN PERMANENT AIR FILTERS.

C. CLEAN DUCTS, BLOWERS, AND COILS IF UNITS WERE OPERATED WITHOUT FILTERS DURING CONSTRUCTION. CLEAN HVAC SYSTEM IN

COMPLIANCE WITH NADCASTANDARD1992-01.

1.6 REPAIR OF THE WORK

A. REPAIR OR REMOVE AND REPLACE DEFECTIVE CONSTRUCTION. WHERE DAMAGED OR WORN ITEMS CANNOT BE REPAIRED OR RESTORED, PROVIDE REPLACEMENTS. RESTORE DAMAGED CONSTRUCTION AND PERMANENT FACILITIES USED DURING CONSTRUCTION TO SPECIFIED

CONDITION.

END OF SECTION 017700

SECTION 017800 - PROJECT RECORD DOCUMENTS

1.1 RECORD DOCUMENTS

PREPARE AND SUBMIT RECORD DOCUMENTS AS FOLLOWS:

A. ONE SET OF MARKED-UP RECORD PRINTS.

B. RECORD SPECIFICATIONS: ONE PAPER COPY.

C. RECORD PRODUCT DATA: ANNOTATED PDF ELECTRONIC FILES AND DIRECTORIES.

D. MISCELLANEOUS RECORD SUBMITTALS: ANNOTATED PDF ELECTRONIC FILES AND DIRECTORIES.

END OF SECTION 017839

SECTION 092116 - GYPSUM BOARD ASSEMBLIES

1.1 SUMMARY:

A. PERFORMANCE CRITERIA FOR GYPSUM BOARD ASSEMBLIES

B. METAL STUD WALL FRAMING

C. METAL CHANNEL CEILING FRAMING

D. ACOUSTIC INSULATION

E. GYPSUM WALLBOARD

1.2 SUBMITTALS

A. PRODUCT DATA

1.3 PRODUCTS:

A. METAL FRAMING MATERIALS

1. C-SHAPED STUDS W/ KNURLED OR EMBOSSED FACES

2. U-SHAPED RUNNER

3. RESILIENT FURRING CHANNEL

4. PARTITION HEAD TO STRUCTURE CONNECTIONS

B. GYPSUM BOARD MATERIALS

1. GYPSUM WALLBOARD

C. GYPSUM BOARD ACCESSORIES

1. ACOUSTIC INSULATION

A. MINERAL-FIBER

2. BEADS

A. METAL CORNER BEADS (90 DEGREE OUTSIDE CORNERS)

3. JOINT MATERIALS

A. PAPER TAPE

B. JOINT COMPOUND

C. FASTENING SCREWS

1.4 INSTALLATION

A. FRAMING INSTALLATION

B. ACOUSTICAL ACCESSORIES INSTALLATION

C. BOARD INSTALLATION

D. JOINT TREATMENT

END OF SECTION 092116

SECTION 079200 - JOINT SEALANTS

1.1 SUMMARY:

A. PERFORMANCE CRITERIA FOR GYPSUM BOARD ASSEMBLIES

B. METAL STUD WALL FRAMING

C. METAL CHANNEL CEILING FRAMING

D. ACOUSTIC INSULATION

E. GYPSUM WALLBOARD

1.2 SUBMITTALS

A. PRODUCT DATA

1.3 WARRANTY

A. 2 YEAR MANUFACTURER WARRANTY

1.4 PRODUCTS:

A. NON-SAG JOINT SEALANTS

1. ACRYLIC ACOUSTICAL SEALANT

1.5 INSTALLATION

END OF SECTION 079200

SECTION 095100 - ACOUSTICAL CEILINGS

1.1 SUMMARY:

A. SUSPENDED METAL GRID CEILING SYSTEM

B. ACOUSTICAL UNITS

1.2 SUBMITTALS

A. PRODUCT DATA

1.3 PRODUCTS:

A. ACOUSTICAL TILE/PANELS

1. ARMSTRONG

A. CORTEGA SECOND LOOK 2767, 24" X 24", WHITE

1.4 SUSPENSION SYSTEMS

A. METAL GRID SUSPENSION SYSTEM

1.5 INSTALLATION

A. SUSPENSION SYSTEM

END OF SECTION 095100

SECTION 096813 - TILE CARPETING

1.1 SUMMARY:

A. CARPET TILE

1.2 SUBMITTALS

A. PRODUCT DATA

B. SAMPLES

1.3 PRODUCTS:

A. PAINT

1. INTERFACE: SHIVER ME TIMBERS

A. CYPRUS #103923, 25 CM X 1 M

B. ACCESSORIES

1. CARPET TILE ADHESIVE

END OF SECTION 096813

SECTION 096500 - RESILIENT FLOORING

1.1 SUMMARY:

A. RESILIENT BASE

1.2 SUBMITTALS

A. PRODUCT DATA

B. SAMPLES

1.3 PRODUCTS:

A. RESILIENT BASE

1. TARKETT FLOORING

A. JOHNSONITE DC-63-4, 4", BURNT UMBER; COVED

END OF SECTION 096500

SECTION 099123 - INTERIOR PAINTING

1.1 SUMMARY:

A. INTERIOR SURFACES

1.2 SUBMITTALS

A. PRODUCT DATA

B. SAMPLES

1.3 PRODUCTS:

A. PAINT

1. SUPPLIER: PAINT WEST, 1606 3500 S. WEST VALLEY, UT 84119

A. COLOR: SLCC REVUE

END OF SECTION 099123

SECTION 081400 - WOOD DOORS

1.1 SUMMARY:

A. FLUSH WOOD DOORS

B. HOLLOW METAL FRAMES

1.2 SUBMITTALS

A. PRODUCT DATA

1. MUST COMPLY WITH ANSI WDMA I.S.1A-2

B. SHOP DRAWINGS

C. SAMPLES

D. WARRANTY

2.1 PRODUCTS:

A. INTERIOR DOORS

1. SOLID CORE DOORS

A. FINISH: PLAIN SLICED RED OAK, CLEAT LACQUER FINISH

B. EXTRA HEAVY DUTY

2. SOUND RATED DOORS

A. FINISH: PLAIN SLICED RED OAK, CLEAT LACQUER FINISH

B. EXTRA HEAVY DUTY

2.2 ACCESSORIES

A. HOLLOW METAL DOOR FRAMES

1. USE SEMI-GLOSS DTM (DIRECT TO METAL) PAINT

2. MATCH COLOR OF EXISTING DOOR FRAMES WHEN PROJECT IS WITH AN EXISTING BUILDING

3. PAINTED DOOR FRAMES TO BE SPRAY PAINTED WITHIN AN EXISTING BUILDING

B. DOOR WINDOW FRAMES

C. DOOR WINDOW GLAZING

1. CLEAR & TEMPERED

3.1 INSTALLATION

END OF SECTION 099123

SECTION 024100 - DEMOLITION

1.1 SUMMARY:

A. SELECTIVE DEMOLITION

1.2 EXECUTION:

A. DEMOLITION

1. REMOVE ALL ELEMENTS MARKED AS DEMOLISHED AS PER DRAWINGS

2. REMOVE AND PRESERVE ALL ELEMENTS MARKED AS PRESERVE/SALVAGED

1.3 GENERAL PROCEDURES AND PROJECT CONDITIONS

A. COMPLY WITH APPLICABLE CODES & REGULATIONS FOR DEMOLITION OPERATIONS AND FOR SAFETY OF THE EXISTING BUILDING AND PUBLIC.

B. DO NOT BEGIN REMOVAL UNTIL RECEIPT OF NOTIFICATION TO PROCEED FROM OWNER

C. PROTECT EXISTING STRUCTURES AND OTHER ELEMENTS TO REMAIN IN PLACE THAT ARE NOT TO BE REMOVED

D. PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES RECYCLABLE MATERIALS

1.4

END OF SECTION 079200

NO. DATE DESCRIPTION

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

N

INTERIOR ELEVATIONS

EXTERIOR ELEVATIONS

BUILDING SECTIONS

WALL SECTIONS

KEYNOTE

DOOR NUMBER

WALL TYPE

ROOM NAME AND

NUMBER

GLAZING TYPE

DATUM

WINDOW TYPE

CENTER LINE

GRID

PROJECT NORTH (UNO)

CEILING TYPE AND

ELEVATION

DETAIL CALL OUT

ROOM FINISH

1t 10' - 0"

XX

A

XXXX

XX

XXXX

XX

XXXX

XX

XXXX

A2

WALL FINISH

FLOOR FINISH

BASE FINISH

SYMBOLS LEGEND

XX

XXXX

XX

XXXX

? MATERIALXXX

ALTERNATE ROOM

FINISH

WALL FINISHES

FLOOR FINISH

BASE FINISH

AE101

Wx Wx

Wx Wx Fx

Bx

ROOM NAME

DIM TO INSIDE

OF DOOR

FRAME. U.N.O.

DIM TO OUTSIDE

OF WINDOW

FRAME. U.N.O.

DIM TO RIGHT OF

STUD, OR TOP

OF STUD. U.N.O.

DIM TO OUTSIDE

OF DOOR FRAME

AT CONCRETE

AND MASONRY

U.N.O.

FRAMED WALLS

CONC & MASONRY WALLS

DIM TO OUTSIDE

OF WINDOW

FRAME U.N.O.

TYPICAL DIMENSIONING KEYABBREVIATIONS

TILE

OTHERWISE

OR SIDEWALK

SQUARE FOOT

FIRE EXTINGUISHER F.E.C.

OF ARCHITECTS

COEFFICIENT

BOARD

BITUM.

PERPENDICULAR PERP.

MISCELLANEOUS MISC.

INFORMATION INFO.

HYD HYDRANT

EXPANSION JOINT E.J.

CABINET

TOP OF FOOTING T.O.F.

GFGI GOVERNMENT FURNISHED

GOVERNMENT INSTALLED

CONTRACTION JOINT C.T.J.

CONSTRUCTION JOINT C.J.

AIR CONDITIONING

CONTRACTOR INSTALLED

TESTING MATERIALS

ADJ.

A.F.F.

ALUM.

A.S.T.M.

BD.

BLDG.

B.M.

B.O.

BRG.

BTWN.

CER.

CLG.

CLR.

CMU

COL.

CONC.

CONT.

CONST.

COORD.

DBL.

DIA.

DTL.

DWGS.

EA.

ELEV.

EQ.

E.S.

EXIST.

EXPAN.

EXT.

E.W.C.

F.D.

FDN.

F.E.

F.F.

FIN.

FLR.

FTG.

GA.

GALV.

GFCI

GND.

GOVT OR GOV.

GWB.

GYP. BD.

HC.

HDW.

H.M.

HORIZ.

HR.

HT.

HVAC

I.D.

INSUL.

LAV.

LT.

MECH.

MANUF OR MFG.

MIN.

M.O.

MTL.

N.I.C.

NO.

N.T.S.

O.C.

O.D.

O.H.

OPP.

PART.

PL.

PNTD.

P.S.I.

R.D.

RAD.

REINF.

REQ'D

RM.

R.O.

S.D.I.

SHR.

SHT.

SIM.

SPEC.

STC

STD.

STR.

SUSP.

THRU

T.O.

T.O.A.

T.O.C.

T.O.S.

T.O.W.

TYP.

VCT

VERT OR VER.

VEST.

W/

WD.

AT

CENTER LINE

ADJUSTABLE

ABOVE FINISH FLOOR

ALUMINUM

AMERICAN SOCIETY FOR

BITUMINOUS

BUILDING

BENCHMARK

BOTTOM OF

BEARING

BETWEEN

CERAMIC

CEILING

CLEAR

CONCRETE MASONRY UNIT

COLUMN

CONCRETE

CONTINUOUS

CONSTRUCTION

COORDINATE

DOUBLE

DIAMETER

DETAIL

DRAWINGS

EACH

ELEVATION

EQUAL

EACH SIDE

EXISTING

EXPANSION

EXTERIOR

ELECTRIC WATER COOLER

FLOOR DRAIN

FOUNDATION

FIRE EXTINGUISHER

FINISH FLOOR

FINISH

FLOOR

FOOTING

GAGE/GAUGE

GALVANIZED

GOVERNMENT FURNISHED

GROUND

GOVERNMENT

GYPSUM WALL BOARD

GYPSUM BOARD

HANDICAPPED

HARDWARE

HOLLOW METAL

HORIZONTAL

HOUR

HEIGHT

HEATING/VENTILATION/

INSIDE DIAMETER

INSULATION

LAVATORY

LIGHT

MECHANICAL

MANUFACTURER

MINIMUM

MASONRY OPENING

METAL

NOT IN CONTRACT

NUMBER

NOT TO SCALE

ON CENTER

OUTSIDE DIAMETER

OVERHEAD

OPPOSITE

PARTITION

PLATE

PAINTED

POUNDS PER SQUARE INCH

ROOF DRAIN

RADIUS

REINFORCED

REQUIRED

ROOM

ROUGH OPENING

STEEL DECK INSTITUTE

SHOWER

SHEET

SIMILAR

SPECIFICATION

SOUND TRANSMISSION

STANDARD

STRUCTURAL

SUSPENDED

THROUGH

TOP OF

TOP OF ASPHALT

TOP OF CURB

TOP OF SLAB

TOP OF WALL

TYPICAL

VINYL COMPOSITION

VERTICAL

VESTIBULE

WITH

WOOD

MAINTENANCE MAINT.

MAXIMUM MAX.

MATERIAL MAT.

OHD OVERHEAD DOOR

PROTECTION PROT.

SUPER. SUPERVISOR

DIAMETER

DEPARTMENT DEPT

ELEVATION EL.

APPROXIMATE APPROX.

GALLONS PER MINUTE GPM

GALLON GAL.

QTY. QUANTITY

MANUFACTURER MFR.

VENEER VNR.

UNLESS NOTED U.N.O.

B.P. BASE PLATE

A.I.A. AMERICAN INSTITUTE

BOT. BOTTOM

C.P. CAP PLATE

A.B. ANCHOR BOLT

E.F. EACH FACE

O.F. OUTSIDE FACE

I.F. INSIDE FACE 3L THREE LAYERS

P.C.F. POUNDS PER CUBIC FOOT

P.S.F. POUNDS PER

LT. WT. LIGHT WEIGHT

S.J.I. STEEL JOIST INSTITUTE

SCHED. SCHEDULE

M.C.J. MASONRY CONTROL JOINT

ARCH. ARCHITECTURAL

ABV. ABOVE

P.L.F. POUNDS PER LINEAL FOOT

O.W.S.J. OPEN WEB STEEL JOIST

FDTN. FOUNDATION

DET. DETAIL

W.W.F. WELDED WIRE FABRIC

IN. INCHES

FT. FEET

H.S.A. HEADED STUD ANCHOR

D.B.A. DEFORMED BAR ANCHOR

STIFF. STIFFENER

E.W. EACH WAY

L ANGLE

RE: REFERENCE TO

W.A.S. WALL AS SCHEDULED

NUMBER#

O.F.C.I. OWNER FURNISHED CONTRACTOR INSTALLED

O.F.O.I. OWNER FURNITHED OWNER INSTALLED

MATERIAL LEGEND

CONCRETE

MASONRY

STEEL

BATT INSULATION

RIGID INSULATION

FINISH GRADE WOOD /

HARDWOOD

PLYWOOD

SPRAY FOAM INSULATION

DEMOLITION, SHOWN

HIDDEN LINE

WOOD STUD

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/2

2/

:2 6:

P

M GI004

SYMBOLS AND

LEGENDS

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

NO. DATE DESCRIPTION

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

GENERAL DEMO NOTES

GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL

REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS OR

CONFLICT IN THE DRAWINGS BEFORE BEGINNING WORK.

DO NOT SCALE DRAWINGS.

ALL EXISTING ITEMS TO REMAIN SHALL BE PROTECTED DURING DEMOLITION

AND CONSTRUCTION.

ALL ITEMS TO BE REMOVED ARE TO BE DISPOSED OF OFF SITE AT THE

APPROPRIATE FACILITY. ITEMS FOR SALVAGE TO BE STORED ON SITE AND

ADEQUATELY PROTECTED FROM WEATHER AND THEFT.

CONTRACTOR IS TO NOTIFY OWNER PRIOR TO REMOVAL OF ANY FIXTURES.

ALL MECHANICAL, PLUMBING AND ELECTRICAL FIXTURES AND RELATED ROUGH-

INS ARE TO BE REMOVED AT AFFECTED AREAS TO NEAREST WALL FOR

REROUTING.

CONTRACTOR TO VERIFY ALL UTILITIES PRIOR TO REMOVAL FOR MOST

ECONOMICAL PATHWAY.

CONTRACTOR IS TO PROVIDE THE OWNER WITH 24 HOURS ADVANCE NOTICE

PRIOR TO ANY UTILITY SHUT-DOWNS OR DISCONNECTS.

ALL UTILITIES ARE TO BE IDENTIFIED AND THEIR LOCATIONS CLEARLY MARKED

BY QUALIFIED ENTITIES PRIOR TO DEMOLITION AND/OR CONSTRUCTION.

ANY STRUCTURAL WALLS TO BE REMOVED ARE TO HAVE THE REMAINDER OF

THE WALLS PROPERLY SHORED UNTIL NEW STRUCTURE IS IN PLACE.

ANY FLOORING OR FLOOR STRUCTURE TO BE REMOVED IS TO HAVE

REMAINDER OF FLOORING OR FLOOR STRUCTURE PROPERLY SHORED UNTIL

NEW STRUCTURE IS IN PLACE.

PATCH AND REPAIR ANY DAMAGE DONE DURING DEMO PHASE. ALL EXISTING

WALL FINISHES TO BE AS SCHEDULED.

TEST DEMOLISHED DOORS FOR ASBESTOS. IF ASBESTOS IS PRESENT. OWNER

SHALL BE RESPONSIBLE COST OF DISPOSAL.

C

D

E

F

11 12 13

033B-A

TESTING LAB

033E

DOUBLE

OFFICE

033D

IT OFFICE

TESTING

CENTER

033B

OBSERVATION

HALLWAY 033F

WORKROOM

033G

DIRECTOR

OFFICE

033A

GED TESTING

001F

HALLWAY

001A

HALLWAY

2.03

CLASSROOM

C

D

E

F

11 12 13

033B-A

TESTING LAB

033E

DOUBLE

OFFICE

033D

IT OFFICE

TESTING

CENTER

033B

OBSERVATION

HALLWAY

033F

WORKROOM

033G

DIRECTOR

OFFICE

033A

GED TESTING

001F

HALLWAY

001A

HALLWAY

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

CLASSROOM

EXIST

9' - 4"

DEMO CEILING LEGEND

DEMO EXISTING LAY-IN GRID CEILING

EXISTING LAY-IN GRID CEILING TO REMAIN.

RETURN GRILL

LIGHTING

PROJECTOR

COMMUNICATION DEVICE(S)

EXIT SIGN

SECURITY CAMERA

DEMO FLOOR LEGEND

WALL TO BE REMOVED, FULL

HEIGHT

WALL TO REMAIN

DOOR AND FRAME TO BE

REMOVED, UNLESS OTHERWISE

NOTED

DOOR AND FRAME TO REMAIN

WINDOW AND FRAME TO BE REMOVED

FLOOR TO BE DEMOLISHED

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/2

2/

:2 6:

P

M AD100

LEVEL 0 RM 020

DEMO FLOOR &

RCP PLAN

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

1/8" = 1'-0"AD100

A1 RM 020 ENLARGED DEMO PLAN

1/8" = 1'-0"AD100

A3

RM 020 ENLARGED DEMO REFLECTED CEILING

PLAN

KEYNOTES

2.03 REMOVE AND PRESERVE DOOR FOR FUTURE REINSTALLATION AT LOCATION

INDICATED

N

NO. DATE DESCRIPTION

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

GENERAL DEMO NOTES

GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL

REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS OR

CONFLICT IN THE DRAWINGS BEFORE BEGINNING WORK.

DO NOT SCALE DRAWINGS.

ALL EXISTING ITEMS TO REMAIN SHALL BE PROTECTED DURING DEMOLITION

AND CONSTRUCTION.

ALL ITEMS TO BE REMOVED ARE TO BE DISPOSED OF OFF SITE AT THE

APPROPRIATE FACILITY. ITEMS FOR SALVAGE TO BE STORED ON SITE AND

ADEQUATELY PROTECTED FROM WEATHER AND THEFT.

CONTRACTOR IS TO NOTIFY OWNER PRIOR TO REMOVAL OF ANY FIXTURES.

ALL MECHANICAL, PLUMBING AND ELECTRICAL FIXTURES AND RELATED ROUGH-

INS ARE TO BE REMOVED AT AFFECTED AREAS TO NEAREST WALL FOR

REROUTING.

CONTRACTOR TO VERIFY ALL UTILITIES PRIOR TO REMOVAL FOR MOST

ECONOMICAL PATHWAY.

CONTRACTOR IS TO PROVIDE THE OWNER WITH 24 HOURS ADVANCE NOTICE

PRIOR TO ANY UTILITY SHUT-DOWNS OR DISCONNECTS.

ALL UTILITIES ARE TO BE IDENTIFIED AND THEIR LOCATIONS CLEARLY MARKED

BY QUALIFIED ENTITIES PRIOR TO DEMOLITION AND/OR CONSTRUCTION.

ANY STRUCTURAL WALLS TO BE REMOVED ARE TO HAVE THE REMAINDER OF

THE WALLS PROPERLY SHORED UNTIL NEW STRUCTURE IS IN PLACE.

ANY FLOORING OR FLOOR STRUCTURE TO BE REMOVED IS TO HAVE

REMAINDER OF FLOORING OR FLOOR STRUCTURE PROPERLY SHORED UNTIL

NEW STRUCTURE IS IN PLACE.

PATCH AND REPAIR ANY DAMAGE DONE DURING DEMO PHASE. ALL EXISTING

WALL FINISHES TO BE AS SCHEDULED.

TEST DEMOLISHED DOORS FOR ASBESTOS. IF ASBESTOS IS PRESENT. OWNER

SHALL BE RESPONSIBLE COST OF DISPOSAL.

DEMO CEILING LEGEND

DEMO EXISTING LAY-IN GRID CEILING

EXISTING LAY-IN GRID CEILING TO REMAIN.

RETURN GRILL

LIGHTING

PROJECTOR

COMMUNICATION DEVICE(S)

EXIT SIGN

SECURITY CAMERA

DEMO FLOOR LEGEND

WALL TO BE REMOVED, FULL

HEIGHT

WALL TO REMAIN

DOOR AND FRAME TO BE

REMOVED, UNLESS OTHERWISE

NOTED

DOOR AND FRAME TO REMAIN

WINDOW AND FRAME TO BE REMOVED

FLOOR TO BE DEMOLISHED

A

B

C

2 3 4

CLASSROOM

090B

STORAGE

WOMEN RR

001C

HALLWAY

001B

HALLWAY

S005

STAIRS

2.02

2.05

2.05

A

B

C

2 3 4

CLASSROOM

090B

STORAGE

WOMEN RR

001C

HALLWAY

001B

HALLWAY

S005

STAIRS

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

2.01

2.04

1/8" = 1'-0"AD101

A1 RM 090 ENLARGED DEMO PLAN

1/8" = 1'-0"AD101

A3

RM 090 ENLARGED DEMO REFLECTED CEILING

PLAN

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/2

2/

:2 6:

P

M AD101

LEVEL 0 RM 090

DEMO FLOOR &

RCP PLAN

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

3KEYNOTES

2.01 REMOVE AND PRESERVE GRID PANELS FOR FUTURE REINSTALLATION

2.02 REMOVE WHOLE WALL PANELS TO THE NEAREST JOINT EAST OF GRID LINE 2

2.04 REMOVE GRID PANELS WHERE NESSESSARY FOR CONSTRUCTION OF NEW

WALL

2.05 REMOVE AND PRESERVE WHITEBOARD. RETURN TO OWNER.

N

NO. DATE DESCRIPTION

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

CEILING LEGEND

RETURN GRILL

EXISTING ACOUSTICAL CEILING TILE

2'x2' ACOUSTICAL CEILING TILE C1 X'-X"

EXIST

X'-X"

SUPPLY DIFFUSER

LIGHTING

FIRE SPRINKLERS & ALARM

MOTION SENSORS

SPEAKERS

PROJECTOR

COMMUNICATION DEVICE(S)

EXIT SIGN

WALL MOUNTED PROJECTOR SCREEN

A

B

C

2 3 4

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

CLASSROOM

090B

STORAGE

090C

CLASSROOM

WOMEN RR

001C

HALLWAY

001B

HALLWAY

S005

STAIRS

CL1

9' - 4"

9.01

9.03

A

B

C

2 3 4

CLASSROOM

090B

STORAGE

090C

CLASSROOM

WOMEN RR

001C

HALLWAY

001B

HALLWAY

S005

STAIRS

A2

A1

9.02

9.02

AE100E1

AE100

C2

D1

D2

E2

B1

B2

C1

090C

4'

1/

8"

39' - 5 3/4" +/-

TYP.

9.02

9.04

TYP.

9.06

TYP.

9.07

TYP.

9.02

9.04

TYP.

9.06

3'

0"

1' - 0"1' - 0"

TYP.

9.07

9.05

GENERAL PLAN NOTES

GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL

REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS OR

CONFLICT IN THE DRAWINGS BEFORE BEGINNING WORK.

DO NOT SCALE DRAWINGS.

FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S

STANDARD DETAILS OR APPROVED SHOP DRAWINGS / DATA SHEETS IN

ACCORDANCE WITH THE PROJECT SPECIFICATIONS.

AT DEMOLISHED & NEWLY CONSTRUCTED WALLS, PATCH & REPAIR CEILING

GRID SYSTEM.

FURNITURE LAYOUT IS PROVIDED AS A CONCEPTUAL LAYOUT. FURNITURE NOT

INCLUDED IN CONTRACT.

INCLUDE AN ALLOWANCE IN THE BID FOR (20) TILES IN ROOM 020 AND (40) TILES

IN ROOM 090.

OWNER IS PROVIDING & INSTALLING SIGNAGE

CLASSROOM

CPT1 BR1

P1 C1

090B

STORAGE

CLASSROOM

090C

CPT1 BR1

P1 C1

WOMEN RR

001C

HALLWAY

001B

HALLWAY

S005

STAIRS

FINISH LEGEND

EXISTING FLOORING TO REMAIN

CARPET

EXT

CPT1

TILE

Fx

OPEN GRATE CAT WALK

Fx(NO ADDITIONAL FINISH)

T1 TRANSITION

FINISH KEY LEGEND

Fx: FLOOR FINISH Bx: BASE MATERIAL / FINISH Wx: WALL FINISH Cx: CEILING FINISH Wx: PLAN TOP WALL FINISH Wx: PLAN RIGHT WALL FINISH Wx: PLAN BOTTOM WALL FINISH Wx: PLAN LEFT WALL FINISH

Fx Bx

Wx Cx

ROOM FINISH TAG

ROOM NAME

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/2

2/

:2 6:

P

M AE100

LEVEL 0 RM 090

FLOOR, FINISH &

RCP PLANS

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

KEYNOTES

9.01 REUSE PREVIOUSLY REMOVED & PRESERVED GRID PANELS. MATCH NEW

GRID TO EXISTING.

9.02 OWNER FURNISHED, CONTRACTOR INSTALLED 8' X 4' WHITE BOARD.

CENTER ON WALL

9.03 PROJECTOR

9.04 ROLLER PROJECTOR SCREEN

9.05 CORK BOARD (EXISTING)

9.06 WALL BASE

9.07 PATCH ALL AREAS AFFECTED BY ELECTRICAL WORK. PAINT TO MATCH

1/8" = 1'-0"AE100

A1 RM 090 ENLARGED FLOOR PLAN

1/8" = 1'-0"AE100

A4 RM 090 ENLARGED REFLECTED CEILING PLAN

N

1/4" = 1'-0"AE100

E1 RM 090 - WEST

1/4" = 1'-0"AE100

C2 RM 090C - NORTH

1/4" = 1'-0"AE100

D1 RM 090 - EAST

1/4" = 1'-0"AE100

E2 RM 090 - NORTH

1/4" = 1'-0"AE100

D2 RM 090 - SOUTH

1/4" = 1'-0"AE100

B1 RM 090C - EAST

1/4" = 1'-0"AE100

B2 RM 090C - SOUTH

1/4" = 1'-0"AE100

C1 RM 090C - WEST

1/8" = 1'-0"AE100

A3 RM 090 ENLARGED FINISH FLOOR PLAN

NO. DATE DESCRIPTION

KEYNOTES APPLY TO ALL ELEVATIONS OF ROOM 090C

KEYNOTES APPLY TO ALL ELEVATIONS OF ROOM 090

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

GENERAL PLAN NOTES

GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL

REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS OR

CONFLICT IN THE DRAWINGS BEFORE BEGINNING WORK.

DO NOT SCALE DRAWINGS.

FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S

STANDARD DETAILS OR APPROVED SHOP DRAWINGS / DATA SHEETS IN

ACCORDANCE WITH THE PROJECT SPECIFICATIONS.

AT DEMOLISHED & NEWLY CONSTRUCTED WALLS, PATCH & REPAIR CEILING

GRID SYSTEM.

FURNITURE LAYOUT IS PROVIDED AS A CONCEPTUAL LAYOUT. FURNITURE NOT

INCLUDED IN CONTRACT.

INCLUDE AN ALLOWANCE IN THE BID FOR (20) TILES IN ROOM 020 AND (40) TILES

IN ROOM 090.

OWNER IS PROVIDING & INSTALLING SIGNAGE

C

D

E

F

G

H

11 12 13

033B-A

TESTING LAB

033E

DOUBLE

OFFICE

033D

IT OFFICE

TESTING

CENTER

CLASSROOM

033B

OBSERVATION

HALLWAY

033F

WORKROOM

033G

DIRECTOR

OFFICE

033H

ADVISOR

OFFICE

033A

GED TESTING

001F

HALLWAY

001A

HALLWAY

RECEPTION

033G

9.02 AE101 D1

D2

E1

E2

HALLWAY

C

D

E

F

11 12 13

033B-A

TESTING LAB

033E

DOUBLE

OFFICE

033D

IT OFFICE

TESTING

CENTER

CLASSROOM

033B

OBSERVATION

HALLWAY

033F

WORKROOM

033G

DIRECTOR

OFFICE

033A

GED TESTING

001F

HALLWAY

001A

HALLWAY

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

EXIST

9' - 4"

TYP.

9.02

TYP.

9.06

9.07

2' - 9" 6' - 0" 6' - 0" 6' - 0" 10' - 7" 7' - 3"

3' - 2 3/4"6' - 0"6' - 0"6' - 0"6' - 0"4' - 1 3/4"

CEILING LEGEND

RETURN GRILL

EXISTING ACOUSTICAL CEILING TILE

2'x2' ACOUSTICAL CEILING TILE C1 X'-X"

EXIST

X'-X"

SUPPLY DIFFUSER

LIGHTING

FIRE SPRINKLERS & ALARM

MOTION SENSORS

SPEAKERS

PROJECTOR

COMMUNICATION DEVICE(S)

EXIT SIGN

WALL MOUNTED PROJECTOR SCREEN

033B-A

TESTING LAB

033E

DOUBLE

OFFICE

033D

IT OFFICE

TESTING

CENTER

EXT BR1

P1 C1

CLASSROOM

033B

OBSERVATION

HALLWAY

033F

WORKROOM

033G

DIRECTOR

OFFICE

033H

ADVISOR

OFFICE

033A

GED TESTING

001F

HALLWAY

001A

HALLWAY

RECEPTION

HALLWAY

FINISH LEGEND

EXISTING FLOORING TO REMAIN

CARPET

EXT

CPT1

TILE

Fx

OPEN GRATE CAT WALK

Fx(NO ADDITIONAL FINISH)

T1 TRANSITION

FINISH KEY LEGEND

Fx: FLOOR FINISH Bx: BASE MATERIAL / FINISH Wx: WALL FINISH Cx: CEILING FINISH Wx: PLAN TOP WALL FINISH Wx: PLAN RIGHT WALL FINISH Wx: PLAN BOTTOM WALL FINISH Wx: PLAN LEFT WALL FINISH

Fx Bx

Wx Cx

ROOM FINISH TAG

ROOM NAME

N

KEYNOTES

9.02 OWNER FURNISHED, CONTRACTOR INSTALLED 8' X 4' WHITE BOARD. CENTER

ON WALL

9.06 WALL BASE

9.07 PATCH ALL AREAS AFFECTED BY ELECTRICAL WORK. PAINT TO MATCH

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/2

2/

:2 6:

P

M AE101

LEVEL 0 RM 020

FLOOR, FINISH &

RCP PLANS

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

1/8" = 1'-0"AE101

A1 RM 020 ENLARGED FLOOR PLAN

1/8" = 1'-0"AE101

A4 RM 020 ENLARGED REFLECTED CEILING PLAN

1/4" = 1'-0"AE101

D1 RM 020 - EAST

1/4" = 1'-0"AE101

E1 RM 020 - WEST

1/4" = 1'-0"AE101

D2 RM 020 - SOUTH

1/4" = 1'-0"AE101

E2 RM 020 - NORTH

1/8" = 1'-0"AE101

A3 RM 020 ENLARGED FINISH FLOOR PLAN

NO. DATE DESCRIPTIONKEYNOTES APPLY TO ALL ELEVATIONS OF ROOM 020

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

2' o.c.3_ 4"

7/8" 3_ 4"

8" MAX.

7/8" 7/8"

Unattached Wall

Attached Wall

Unattached W all

B or P B

B

B

B

B

B

B

B

BBB

UNATTACHED

WALL

ATTACHED

WALL

B or P B or P

1-1/2"

TOTAL

TRAVEL

OPTIONAL

ATTACHED

WALL

POP RIVETSCREW TIGHTENED THROUGH MAIN

RUNNER WEB RESTRICTING

SEPARATION FRM WALL MOLDING

SEISMIC CLIPS OR POP RIVETS

8" MAX.

8" MAX.

PERIMETER WIRE 48" O.C.

& WITHIN 8" OF WALL

° M

AX

45° M

AX

45° MAX45

° M

AX

MAIN RUNNER

CROSS RUNNER

2" MIN. 2" MIN.

(4) #12 GAGE WIRES SECURED TO MAIN

RUNNER WITHIN 2" OF CROSS RUNNER

INTERSECTION & SPLAYED 90 DEGREES

FROM EACH OTHER AT ANGLE NOT

EXCEEDING 45 DEGREES FROM

HORIZONTAL PLANE OF CEILING.

COMPRESSION STRUT FROM THE

MAIN RUNNER TO THE

STRUCTURE ABOVE.

1.

2.

3.

4.

NOTES:

HEAVY DUTY GRID

ELECTRICAL OR OTHER FIXTURES SHALL NOT BE

DESIGNED TO COMPROMISE CEILING PERMFORMANCE

WIRES TIES SHALL HAVE NO LESS THAN 3 TURNS

CEILING DESIGN & INSTALLATION SHALL COMPLY WITH ASCE

7 CURRENT EDITION

5/

8" TY

P

5/ 8"

1"

J-MOLD TRIM

LONG-LEG SLIP

TRACK

ACOUSTIC BATT

INSULATION

CAULK

METAL DECK

PAINT-ABLE CAULK

ALL AROUND

PAINTED HOLLOW MTL. DOOR &

ANCHORED W/ MASONRY

ANCHORS

DOOR AS SCHEDULED

PLASTER

EXISTING CMU

EXISTING CMU

PAINT-ABLE CAULK ALL

AROUND

PAINTED HOLLOW MTL. DOOR

FRAME MINERAL WOOL

FILLED & ANCHORED W/

MASONRY ANCHORS

PLASTER

- V

IF

7"

DOOR TYPES

B

1T

FRAME TYPES

A5

AE501

A4

AE501

SOLID CORE WOOD STAIN

STANDARD NARROW LIGHT

2"x X HM FRAME.

PAINT: DRF1

SE

E

SC

H

2"

2" SEE SCH 2"

A

(EXISTING) SOLID CORE

WOOD DOOR

5/8" GYP. BD.

6" 20 GA. METAL STUD @ 16" O.C.

FIRE TEST:

SOUND TEST:

FIRE RATING:

STC RATING:

WALL HEIGHT:

A2 N/A

UL: V438, U465

STC-53

TO DECK

SOUND BATT

INSULATION.

RC-1

5/8" GYP. BD.

3 5/8" 20 GA. METAL STUD @ 16" O.C.

FIRE TEST:

SOUND TEST:

FIRE RATING:

STC RATING:

WALL HEIGHT:

A1 N/A

NGC 2018106

STC-46

6" ABOVE WALL

SOUND BATT

INSULATION.

LAY-IN ACOUSTIC PANEL

SUSPENSION WIRE TO

STRUCTURE

CL1

DOOR JAMB

DOOR STOP

ESD VINYL TILE

DOOR PER SCHEDULE,

WHERE OCCURS

TYP CARPET REDUCER TRANSITION

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/2

2/

:2 6:

P

M AE501

WALL & DOOR

TYPE,

SCHEDULES &

DETAILS

25-027

BID SET 2025-12-19

SL

C

C R

M

R

EM

O D

EL

C

O M

M U

N

IT

Y

BL

VD

TA

YL

O

R

SV

IL

LE

, U T

DOOR SCHEDULE

DOOR # SIZE DOOR TYPE FRAME TYPE HARDWARE GROUP COMMENTSWIDTH HEIGHT THICKNESS

020 3' - 0" 7' - 0" 1 3/4" B A CLASSROOM SET

033G 3' - 0" 7' - 0" 1 3/4" A A CLASSROOM SET PREVIOUSLY SALVAGED DOOR FROM RM 020

090 3' - 0" 7' - 0" 1 3/4" B A CLASSROOM SET

090C 3' - 0" 7' - 0" 1 3/4" B A CLASSROOM SET

1/2" = 1'-0"AE501

A1 LAY-IN CEILING SEISMIC BRACING

3" = 1'-0"AE501

B4 STC 50 WALL DEFLECTION TRACK

3" = 1'-0"AE501

A4 HM DOOR HEAD - INTERIOR WALL

3" = 1'-0"AE501

A5 HM DOOR JAMB - INTERIOR WALL

FINISH LEGEND

KEY DESCRIPTION MANUFACTURER STYLE/PATTERN COLOR/FINISH SIZE NOTES

BASE FINISHES

BR1 RUBBER BASE JOHNSONITE JOHNSONITE DC-63-4 BURNT UMBER 4" COVED.

EXT EXISTING TO REMAIN

CEILING

C1 ACT ARMSTRONG CORTEGA SECOND LOOK 2767 WHITE 24" X 24" X 3/4"

EXT EXISTING TO REMAIN

DOOR FRAME FINISH

DRF1 PAINT PAINT WEST SLCC CONSTRUCTION TRADE DOOR FRAMES

FLOOR FINISHES

CPT1 CARPET TILE INTERFACE SHIVER ME TIMBERS CYPRUS #103923 25 CM X 1 M INSTALL ASHLAR

EXT EXISTING TO REMAIN

T2 TRANSITION GENOTEK REDUCER STAINLESS #530

WALL FINISHES

EXT PAINT PAINT WEST SLCC REVUE

P1 EXISTING TO REMAIN

NO. DATE DESCRIPTION

6" = 1'-0"AE501

E1 T1 TRANSITION

REVIEWED FOR CODE

COMPLIANCE

BY: _____________________

DATE: ______________01/12/2026

The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.

SD

A

M101

A

M-101

T

12/12 CD-1

(2) 200

DUCTWORK/GRILLES PIPING PLUMBING LINETYPES LINETYPES CONT.

N

LB/HR.GPM

12ø 4'-0"(1) - 1" SLOTS

L-1 200 CFM (RADIUS)

W R

12/12

45° D

FD

FSD

SD

OR

8/8

1.25D

AD

12/8 FO

ATC

CF

AW

AV

HP(NAME)

N20

(NAME)

R

12/8

12ø

UP

DN

12/12 12ø

1.5D

D

12∅ 12/12

HFR

HFS

FOR

FOS

HG

(NAME)

LPG

G(NAME)

GHR

HWR

HWS

E(NAME)

G

MUW

BF

BBD

HPS

MPS

LPS

HPC

LPC

P-1

OX

MA

MA 120

MV

N

C02

CA

LA

LV

B

CR

CS

CHWR

CHWS

IA

IA 120

MPC

BDD

SW

OX 120

RS

RL

V

RDO

RD

ROR

F

DI

DIR

RO

FOV

S

T

S

RPBP

THERMOSTATIC MIXING VALVE

REDUCED PRESSURE BACKFLOW

PREVENTOR W/ DRAIN PAN

FUEL OIL VENT

REVERSE OSMOSIS WATER SUPPLY

DEIONIZED WATER RETURN

DEIONIZED WATER SUPPLY

RISE OR DROP

FIRE SPRINKLER WATER

DRAIN PAN AND P-TRAP

FILL PORT

VALVE IN RISE

PRESSURE REDUCING VALVE SELF CONTAINED

COTG

FCO

MEDICAL OXYGEN AT PRESSURE

INDICATED

REVERSE OSMOSIS WATER RETURN

SOFT DOMESTIC WATER

VENT (SEWER)

SEWER (ABOVE GRADE)

SEWER (BELOW GRADE)

ROOF DRAIN OVERFLOW

ROOF DRAIN

VACUUM

PUMPED CONDENSATE

REFRIGERANT LIQUID

REFRIGERANT SUCTION

UNIT HEATER

DUCT SMOKE DETECTOR

3-WAY BLOW

PATTERN

2-WAY BLOW

PATTERN

1-WAY BLOW PATTERN

NEGATIVE PRESSURE DUCT - RISE

POSITIVE PRESSURE DUCT - DROP

POSITIVE PRESSURE DUCT - RISE

BACK DRAFT DAMPER

CEILING RETURN AIR GRILE

W/ SOUND BOOT

DOWNSPOUT NOZZLE

ROOF DRAIN

SENSOR

THERMOSTAT

SWITCH

HOSE BIBB

AIR VENT-AUTO

AIR VENT-MANUAL

FLOOR DRAIN

FLOOR SINK

SPRINKLER HEAD

FIRE RISER

BRANCH - TOP CONNECTION

BRANCH - BOTTOM CONNECTION

MEDIUM PRESSURE CONDENSATE

INSTRUMENT AIR AT PRESSURE

INDICATED

INSTRUMENT AIR

CHILLED WATER SUPPLY

CHILLED WATER RETURN

CONDENSER WATER SUPPLY

CONDENSER WATER RETURN

FIXTURE FROM LEVEL ABOVE

BRINE

LAB VACUUM

LAB AIR

COMPRESSED AIR

CARBON DIOXIDE

NITROUS OXIDE

NITROGEN

MEDICAL VACUUM

MEDICAL AIR AT PRESSURE INDICATED

MEDICAL AIR

MEDICAL OXYGEN

HIGH PRESSURE DOMESTIC WATER

ACID VENT

ACID WASTE

KEYED NOTE IDENTIFICATION

EQUIPMENT IDENTIFICATION

DETAIL TAG - TOP FIGURE IS DETAIL NO.

BOTTOM FIGURE IS SHEET NO.

SECTION TAG - TOP FIGURE IS SECTION NO.

BOTTOM FIGURE IS SHEET NO.

POINT OF CONNECTION

PLUMBING

FIXTURES

DOMESTIC HOT WATER RETURN

(DHWR)

DOMESTIC HOT WATER (DHW)

DOMESTIC COLD WATER (DCW)

FLOOR CLEAN-OUT

OR CLEAN-OUT TO

GRADE

HOSE

VALVE

FLOW SWITCH

NRS GATE VALVE WITH

SUPERVISION

BRANCH - SIDE CONNECTION

RISER - UP (ELBOW)

RISER - DOWN (ELBOW)

ARROW INDICATES DIRECTION OF FLOW IN

PIPE

NIGHT THERMOSTAT

45° ELBOW

90° ELBOW

CALIBRATED BALANCING

VALVE WITH GPM INDICATED

GLOBE VALVE

CHECK VALVE

GATE VALVE

RELIEF VALVE

ANGLE VALVE

PRESSURE REDUCING VALVE EXTERNAL PRESSURE

SOLENOID VALVE

FLOW SWITCH

REDUCER

LOW PRESSURE CONDENSATE

HIGH PRESSURE CONDENSATE

LOW PRESSURE STEAM

MEDIUM PRESSURE STEAM

HIGH PRESSURE STEAM

BOILER BLOW DOWN

BOILER FEED WATER

MAKE UP WATER

NATURAL GAS

EXISTING PIPING

HEATING HOT WATER SUPPLY

HEATING HOT WATER RETURN

GLYCOL HEAT RECOVERY PIPING

GLYCOL PIPING SOLUTION

LIQUIFIED PETROLEUM GAS

EXISTING PIPING TO BE

REMOVED

HOT GAS

FUEL OIL SUPPLY

FUEL OIL RETURN

HELICOPTER FUEL SUPPLY

HELICOPTER FUEL RETURN

CHEMICAL FEED

DEMOLITION

TOP

FIGURES INDICATE

NECK SIZE AND TYPE.

BOTTOM

FIGURE INDICATES

QUANTITY AND CFM.

NEGATIVE PRESSURE DUCT - DROP

ROUND DUCT - RISE

ROUND DUCT - DROP

UNDER FLOOR DUCT

TURNING VANES

FRESH AIR LOUVER

RELIEF AIR OR EXHAUST AIR LOUVER

CEILING SUPPLY DIFFUSER

CEILING RETURN REGISTER

CEILING EXHAUST REGISTER,

(BALANCE TO MATCH SUPPLY IF

RETURN CFM IS NOT SHOWN)

SIDEWALL SUPPLY

REGISTER

SIDEWALL EXHAUST OR

RETURN REGISTER

CEILING SUPPLY DIFFUSER

WITH FLEXIBLE DUCT

CEILING AIR GRILLE WITH

FLEXIBLE DUCT

LINEAR DIFFUSER WITH PLENUM AND FLEXIBLE

DUCT CONNECTION. TOP : DUCT SIZE, ACTIVE

LENGTH, NO. OF SLOTS & SIZE OF SLOT.

BOTTOM: TYPE , CFM, RADIUS (IF APPLICABLE).

FLEXIBLE DUCT CONNECTION

FLEXIBLE DUCT

FLAT OVAL DUCT WITH NET INSIDE

DIMENSIONS SHOWN IN INCHES.

RECTANGULAR DUCT WITH NET INSIDE

DIMENSIONS SHOWN IN INCHES.

ROUND DUCT WITH NET INSIDE DIMENSIONS

SHOWN IN INCHES.

WITH RESPECT TO AIR FLOW 15°

NOMINAL INCLINE WITH RADIUS

TURNS=DEPTH OF DUCT.

INCLINED RISE

INCLINED DROP

R/W=1. ROUND DUCT SIMILAR TO RECTANGULAR

RECTANGULAR TO RECTANGULAR OR ROUND TO ROUND

DUCT TRANSFORMATION MAXIMUM 15° INCLUDED ANGLE

EXCEPT WHERE SHOWN OTHERWISE.

RECTANGULAR TO ROUND DUCT TRANSFORMATION

BRANCH DUCT SPLIT WITH 6" WIDTH AND MIN.

R=WIDTH OF BRANCH DUCT DOWNSTREAM.

ELBOW TURNING VANE OPTIONAL.

TAP ENTRY AREA EQUALS 150% OF BRANCH AREA

HIGH EFFICIENCY FITTING

MANUAL VOLUME DAMPER

FIRE DAMPER IN DUCT, W/ ACCESS PANEL REQD.

COMBINATION FIRE/SMOKE DAMPER W/ ACCESS PANEL

SMOKE DAMPER W/ ACCESS PANEL

ATC DAMPER

ACCESS PANEL IN DUCT OR PLENUM

HEATING OR COOLING COIL IN DUCT

SINGLE DUCT AIR TERMINAL BOX VARIABLE OR

CONSTANT VOLUME. MIN. 1-1/2 TERMINAL INLET

SIZE STRAIGHT DUCT AT TERMINAL INLET.

LATERAL STRAINER WITH BLOW-OFF VALVE,

PROVIDE HOSE END WITH CAP WHERE DISCHARGE

IS NOT PIPED TO DRAIN

LEGEND OF MECHANICAL SYMBOLS AND ABBREVIATIONS

SHUT OFF VALVE

BALL VALVE

BUTTERFLY VALVE

MOTOR OPERATED BUTTERFLY VALVE

GATE VALVE - NON RISING STEM

PLUG VALVE

ATC - 2 WAY VALVE

ATC - 3 WAY VALVE

S

F&T=FLOAT & THERMOSTATIC

VENTURI FLOW METER

FLOW METER ORIFICE

PS

PRESSURE SWITCH

TEMPERATURE AND PRESSURE

TEST PORT

THERMOMETER WELL

THERMOMETER - TEMP RANGE AS INDICATED

PRESSURE GAUGE WITH

SHUT OFF PLUG VALVE

-1

F

PRESSURE GAUGE WITH PIGTAIL

UNION

FLANGE

ECCENTRIC REDUCER

PIPE CAP

SHUT OFF PLUG VALVE FOR

FOR USE WITH PRESSURE GAUGE

DN

LEADER INDICATES DOWNWORD SLOPE

FLEXIBLE EXPANSION JOINT

ALIGNMENT GUIDE

ANCHOR

VTR

WATER HAMMER ARRESTOR

VENT THRU ROOF

CLEAN-OUT

ANNOTATIONS

FIRE

EQUIPMENT

INLINE PUMP

FAN

INLINE PUMP

ICW

IHW

ISCW

IHWR

INDUSTRIAL SOFT COLD WATER

INDUSTRIAL HOT WATER RETURN

INDUSTRIAL HOT WATER

INDUSTRIAL COLD WATER

LW

LWR

LAB WATER

LAB WATER RETURN

TW

TWR TEMPERED WATER RETURN

TEMPERED WATER

FVS FLUSH VALVE SUPPLY

PC

GPM0.0

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

OR

WIDTH X HEIGHT

R.A. LOUVER

WIDTH X HEIGHT

O.A. LOUVER

12/12 RG-1

(2) 200

12/12 EG-1

(2) 200

12/12 SWS-1

(2) 200

12/12 SWR-1

(2) 200

12/12 CD-1

(2) 200

12/12 RG-1

(2) 200

2-WAY BLOW

PATTERN

4-WAY BLOW

PATTERN

F&T

A

L I C

E N

S E

D

P

ROFESS IONA

L

E N

G I N

E E

R

No. 8325442-2202

S

T A

T E OF U

TA

H

JACOB D.

BECK

12-19-25

PROJECT

REVISIONS

54321

D

C

B

A

E

54321 6

/1

/2

:3

:2

A

M

M000

MECHANICAL

SYMBOLS AND

LEGEND

25-027

BID SET 2025-12-19

S L

C C

R M

R

E M

O D

E L

C

O M

M U

N

IT

Y B

L V

D T

A Y

L O

R S

V

IL

L E

U

T

NO. DATE DESCRIPTION

REVIEWED…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .