6-SLCC RM 020 090 BID SET DRAWINGS 01-12-2026.pdf
PDF 17 MB Posted
- Attached to
- SLCC CT Classroom Remodel 020 090
- Solicitation number
- SLCC2026-W1014
- Issued by
- Salt Lake County, Salt Lake City, Utah
About this file
This is a Bid Set Drawing package for an interior tenant improvement project at Salt Lake Community College (SLCC) located at 1830 Community Boulevard, Taylorsville, Utah 84123. The project involves the remodeling of Rooms 020 and 090, which will function as classroom and testing center spaces. The scope of work includes selective demolition of existing walls, ceilings, flooring, and mechanical/electrical/plumbing systems; installation of new gypsum board assemblies, acoustical ceilings, resilient flooring, carpet tiles, and interior painting; reconfiguration of mechanical HVAC systems with VAV boxes and ductwork modifications; electrical system upgrades including new lighting fixtures, receptacles, wiring, and fire alarm devices; and restoration of finishes and systems to code-compliant conditions. The project documents indicate separate cost line items must be provided for work in Rooms 020 and 090. The drawings are dated January 12, 2026, with a revision response to comments dated January 7, 2026. The contract is structured as a stipulated sum (single prime contract) with the tenant providing builder's risk insurance and the general contractor demonstrating comprehensive liability and automobile liability coverage.
The project specifications require compliance with 2021 International Building Code, 2021 International Mechanical Code, 2021 International Plumbing Code, 2021 International Fire Code, 2021 International Electrical Code, and 2023 National Electrical Code standards. Deferred submittals are required for fire alarm and fire sprinkler systems, with final design and specifications to be provided by the contractor. The project includes allowances for spare ceiling tiles (20 tiles for Room 020 and 40 tiles for Room 090) and requires coordination with the building owner for contractor staging areas, delivery entrances, and parking. Final completion requirements include code inspection reports, fire marshal clearance, elevator and boiler inspector approvals where applicable, and certificates of compliance from fabricators. The documents note that the owner will furnish and install certain items such as whiteboards and signage, while the contractor is responsible for receiving, handling, storage, installation, and protection of owner-furnished materials.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-Certificate-of-Substantial-Completion (1).docx | DOCX document | |
| 7-SLCC RM 020 090 PROJECT MANUAL 01-12-2026.pdf | ||
| 5-Invitation for Bid - SLCC CT Classroom Remodel 020 090.docx | DOCX document | |
| 1-SALT LAKE COMMUNITY COLLEGE GENERAL BID PROVISIONS.pdf | ||
| 4-Subcontractors+List (1).docx | DOCX document | |
| 3-Contractors-Agreement (1).docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DFCM SUBMITTAL NOTES
1. A CODE INSPECTION REPORT RECOMMENDING THAT A CERTIFICATE OF OCCUPANCY BE ISSUED.
2. CERTIFICATE OF FIRE CLEARANCE FROM THE SLCC FIRE MARSHALL.
3. FINAL APPROVAL FROM THE STATE ELEVATOR INSPECTOR, IF APPLICABLE.
4. FINAL APPROVAL FROM THE STATE BOILER INSPECTOR, IF APPLICABLE.
5. A CERTIFICATE OF COMPLIANCE FROM THE APPROVED FABRICATOR, IF APPLICABLE. IBC 1704.2.2
North: ______ South: ______ East: ______ West: ______
Special Use and Occupancy (e.g. High Rise, Covered Mall): __________________
Official for Complex Buildings. Including, but not limited to:
g) Fire Stopping, Including Tested Design Number.
f) Exterior and Interior Accessibility Route.
e) Fire Assembly Locator Sheet.
a) High Rise Requirements.
b) Atriums.
c) Performance Based Criteria.
d) Means or Egress Analysis.
2) Additional Code Information shall be provided at the discretion of the Building
Code Accessibility Chapters, the more restrictive requirement shall govern.
through - ADA Guidelines and specific reference to the International Building
1) In case of conflict with the U.S. Department of Justice Federal Registers Parts
FOOTNOTES:
M. Minimum Number of Required Plumbing Facilities:
FIXTURES REQUIRED & PROVIDED UNCHANGED BY REMODEL.
Exit Width Required: _______________ Exit Width Provided: _______________
Element Hours Assembly ListingListingElement AssemblyHours
Smoke Partitions Fire Partitions
Exterior Bearing Walls Interior Bearing Walls Exterior Non-Bearing Walls Structural Frame Partitions - Permanent Fire Barriers
Floors - Ceiling Floors Roofs - Ceiling Roofs Exterior Doors and Windows Shaft Enclosures Fire Walls
BAHTBABABA
Design Wind Speed: ______ mphB. Seismic Design Category: ______
L. Design Occupant Load: ____________
K. Fire Resistance Rating Requirements for Building Elements (hours).
Area Modifications:J:
____________________________________________Tabular Area:I:
per Floor (square feet): Actual AreaH:
Number of Stories: ______ Building Height: _____________G:
Required: ______ Provided: ______ Type of Sprinkler System: ____________ Sprinklers:F:
Mixed Occupancies: ______ Nonseparated Uses: ______E.
separation distance (in hours):
Requirements for the Exterior Walls based on the fireFire Resistance RatingD.
C. Type of Construction (circle one):
Change in Use: Yes ______ No ______ Mixed Occupancy: Yes _____ No ______
Guildelines ADA Accessibility Building Conservation Uniform Code for National Electrical Code
Conservation Code International Energy International Fire Code International Plumbing Code International Mechanical Code International Building Code
YearYear
APPLICABLE CODES
A. Occupancy and Group: ________ ________ ________ ________ ________
CODE ANALYSIS
B
XX
TBD N/A
N/A N/A N/A N/A
UNCHANGED
L1= UNCHANGED
N/A N/A N/A N/A
UNCHANGED
UNCHANGED
UNCHANGED
UNCHANGED
UNCHANGED
NOT APPLICABLE
3 UNCHANGED
N/A0
92,000 SQFT PER FLOOR
L2= UNCHANGED
Basement= UNCHANGED
NOT APPLICABLE
Total= UNCHANGED
Stair Width Required: ____________ Stair Width Provided: ____________
N/A
1. DEFERRED SUBMITTALS WILL INCLUDE FIRE ALARMS AND FIRE SPRINKLERS.
Gas Code International Fuel ICC-A117.1
Accessibility Standard
Stair Occupant Load: _____________UNCHANGED
REQUIREMENTS FOR OCCUPANCY
EXIST.
PROJECT DIRECTORY
ARCHITECT
CRSA
STEVE SIMMONS
(801) 355-5915
STEVE@CRSA.COM
MECHANICAL ENGINEER
RESOLUT GROUP
JAKE BECK
(801) 530-3148
JBECK@RESOLUTGROUP.COM
ELECTRICAL ENGINEER
MATTHEW HARVERKAMP
SPECTRUM ENGINEERING
(800) 678-7077
MATT.HAVERKAMP@SPECENG.COM
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
1/ 7/
1:
:1
AM GI000
COVER SHEET
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
NONSTRUCTURAL COMPONENT CHECKLIST
ITEM DESCRIPTION
NOT
REQUIRED
ON CONST.
DOCUMENTS
DEFERRED
SUBMITTAL COMMENTS
ARCHITECTURAL COMPONENTS:
Interior Nonstructural Walls & Partitions X Cantilever Elements (i.e. parapets, etc.) X Exterior Nonstructural Wall Elements X Veneer X Penthouse X Ceilings (i.e. suspended grid or hard-lid) X Cabinets (i.e. storage cabinets, equip, etc.) X Access Floors X Storage Racks X Appendages & Ornamentations X Signs & Billboards X Others:
Others: X
MEP COMPONENTS: X
Fire Sprinklers X Mechanical Equipments (i.e. HVAC, fans, air handlers, boilers, furnaces, tanks, chillers, water heaters, heat exchangers, evaporates, engines, turbines, pumps, compressors, MFR equipments, etc.)
X Mechanical Submittal
Electrical Equipments (i.e. generators, batteries inverters, transformers, MCC, panel boards, switch gear, cabinets, etc.)
X Electrical Submittal
Elevator & Escalator Components X Communication Equipments, Computers, Instrumentation, and Controls X Roof - mounted Chimneys, Stacks, Cooling & Electrical Towers X Lighting Fixtures X Vibration Isolated Components X Piping & Conduit System X Mechanical & Electrical Submittal Ductwork (including in-line components) X Mechanical Submittal Conveyors X Cable Trays X Electrical Submittal Others: X Others: X
SHEET INDEX
GENERAL INFORMATION
GI000 COVER SHEET
GI001 LEVEL 0 LIFE SAFETY PLAN
GI002 LEVEL 1 LIFE SAFETY PLAN
GI003 ARCHITECTURAL SPECIFICATIONS
GI004 SYMBOLS AND LEGENDS
ARCHITECTURE
AD100 LEVEL 0 RM 020 DEMO FLOOR & RCP PLAN
AD101 LEVEL 0 RM 090 DEMO FLOOR & RCP PLAN
AE100 LEVEL 0 RM 090 FLOOR, FINISH & RCP PLANS
AE101 LEVEL 0 RM 020 FLOOR, FINISH & RCP PLANS
AE501 WALLS, DOOR TYPES, SCHEDULES & DETAILS
MECHANICAL
M000 MECHANICAL SYMBOLS AND LEGEND
M001 MECHANICAL GENERA NOTES
M100 LEVEL 0 MECHANICAL PLAN
M401 ENLARGED MECHANICAL PLANS
M402 ENLARGED MECHANICAL PLANS
M501 MECHANICAL DETAILS & SCHEDULES
M701 MECHANICAL SPECIFICATIONS
M702 MECHANICAL SPECIFICATIONS
ELECTRICAL
EE001 ELECTRICAL COVER SHEET
EE002 ELECTRICAL SPECIFICATIONS
EE003 ELECTRICAL SPECIFICATIONS
EE004 TELECOM SCHEDULES AND NOTES
EE501 ELECTRICAL DETAILS
EE701 TYPICAL MOUNTING DETAILS
ED100 OVERALL ELECTRICAL DEMOLITION PLAN
ED101 RM 090 ELECTRICAL DEMOLITION PLAN
ED102 RM 020 ELECTRICAL DEMOLITION PLAN
EP100 OVERALL ELECTRICAL PLAN
EP101 ROOM 090 ENLARGED ELECTRICAL PLAN
EP102 ROOM 020 ENLARGED ELECTRICAL PLAN
EP601 ELECTRICAL SCHEDULES
EP615 PANEL SCHEDULES
EY601 FIRE ALARM RISER DIAGRAMS
SLCC RM 020 & 090 REMODEL
1830 COMMUNITY BLVD
TAYLORSVILLE, UT 84123
NOTES TO BIDDERS:
PROVIDE SEPARATE COSTS IN THE BID FOR WORK IN ROOMS 020 & 090
NO. DATE DESCRIPTION
1 2026/01/07 RESPONSE TO
COMMENTS
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
GRW
Call 801-403-8152 for Inspections
Haverkamp
10221159-2202 Matthew John
L
IC
EN
S E
D
PROF E S S I ONA L
ENG
I NEER
S T A T E O F U T A H
No.
11/21/2025
L I C
E N
S E
D
P
ROFESS IONA
L
E N
G I N
E E
R
No. 8325442-2202
S
T A
T E OF U
TA
H
JACOB D.
BECK
12-19-25
CLASSROOM
090C
CLASSROOM
WOMEN RR
MEN RR
082A
STORAGE
001C
HALLWAY
001B
HALLWAY
090B
STORAGE
S005
STAIRS
TESTING
CENTER
001A
HALLWAY
033B-A
TESTING LAB
HALLWAY
033D
IT OFFICE
033E
DOUBLE
OFFICE
033F
WORKROOM
033B
OBSERVATION
033A
GED TESTING
RECEPTION
033G
DIRECTOR
OFFICE
033H
ADVISOR
OFFICE
63' - 4" 232' - 3"
67' - 8" 214' - 5"
71' - 1" 165' - 9"
69' - 11" 82' - 7"
71' - 1" 215' - 2"
S001
STAIRS
CLASSROOM
FILE SECURE
STORAGE
001F
HALLWAY
EXIT
LIFE SAFETY LEGEND
EXIT ACCESS PATH
EXIT SIGN
EGRESS PATH
TRAVEL DISTANCE
30' - 0" 50' - 0"
COMMON PATH
OF TRAVEL
ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPMENT ROOM
EDUCATIONAL
BUSINESS AREAS
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/2
2/
:2 6:
P
M GI001
LEVEL 0 LIFE
SAFETY PLAN
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
3/32" = 1'-0"GI001
A1 LEVEL 0 LIFE SAFETY PLAN
N
OCCUPANT LOAD BY ROOM
MARK ROOM NAME AREA ROOM FUNCTION OCCUPANT LOAD FACTOR OCCUPANTS EXIT WIDTH TOTAL
020 TESTING CENTER 884 SF EDUCATIONAL - CLASSROOM AREA (20 SF NET) 20 45 9.00"
033 HALLWAY 415 SF BUSINESS AREAS (100 SF GROSS) 100 5 1.00"
033 RECEPTION 250 SF BUSINESS AREAS (100 SF GROSS) 100 3 0.60"
033A GED TESTING 704 SF BUSINESS AREAS (100 SF GROSS) 100 8 1.60"
033B OBSERVATION 136 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"
033B-A TESTING LAB 559 SF BUSINESS AREAS (100 SF GROSS) 100 6 1.20"
033D IT OFFICE 119 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"
033E DOUBLE OFFICE 177 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"
033F WORKROOM 73 SF BUSINESS AREAS (100 SF GROSS) 100 1 0.20"
033G DIRECTOR OFFICE 124 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"
033H ADVISOR OFFICE 100 SF BUSINESS AREAS (100 SF GROSS) 100 2 0.40"
090 CLASSROOM 955 SF EDUCATIONAL - CLASSROOM AREA (20 SF NET) 20 48 9.60"
090B STORAGE 149 SF ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM (300 SF GROSS) 300 1 0.20"
090C CLASSROOM 974 SF EDUCATIONAL - CLASSROOM AREA (20 SF NET) 20 49 9.80"
TOTAL OCCUPANT LOAD (PER
LEVEL) 5620 SF 176 35.20"
NO. DATE DESCRIPTION
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
GRW
Call 801-403-8152 for Inspections
LIFE SAFETY LEGEND
EXIT ACCESS PATH
EXIT SIGN
EGRESS PATH
TRAVEL DISTANCE
30' - 0" 50' - 0"
COMMON PATH
OF TRAVEL
ACCESSORY STORAGE AREAS, MECHANICAL
EQUIPMENT ROOM
EDUCATIONAL
BUSINESS AREASEXIT
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/2
2/
:2 6:
P
M GI002
LEVEL 1 LIFE
SAFETY PLAN
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
N
3/32" = 1'-0"GI002
A1 LEVEL 1 LIFE SAFETY PLAN
NO. DATE DESCRIPTION
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/2
2/
:2 6:
P
M GI003
ARCHITECTURAL
SPECIFICATIONS
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
SECTION 011000 - SUMMARY
1.1 PROJECT
PROJECT NAME: SLCC RM 020 & 090 REMODEL
OWNER: SALT LAKE COMMUNITY COLLEGE
ARCHITECT: CRSA
1.2 CONTRACT DESCRIPTION
A. STIPULATED SUM (SINGLE PRIME CONTRACT)
1.3 SUPPLEMENTARY CONDITIONS
A. INSURANCE REQUIREMENTS
1. THE TENANT SHALL PROVIDE BUILDER’S RISK INSURANCE DURING CONSTRUCTION AND PROPERTY AND LIABILITY INSURANCE FOR
COMPLETED IMPROVEMENTS.
2. THE TENANT’S GENERAL CONTRACTOR MUST DEMONSTRATE A CERTIFICATE OF INSURANCE LICENSED IN THE STATE OF UTAH SHOWING FULL COVERAGE OF THE CONTRACTOR FOR COMPREHENSIVE AUTOMOBILE LIABILITY AND COMMERCIAL GENERAL LIABILITY.
1.4 SCOPE OF WORK
A. SCOPE OF WORK OF PROJECT: INTERIOR TENANT IMPROVEMENT WITHIN AN EXISTING BUILDING AS INDICATED IN THE CONTRACT DOCUMENTS.
B. USE OF SITE: LIMITED TO WORK IN AREAS INDICATED. COORDINATE WITH BUILDING OWNER FOR CONTRACTOR STAGING AREAS, CONTRACTOR
DELIVERY ENTRANCES AND CONTRACTOR PARKING AREAS.
C. TENANT'S OCCUPANCY REQUIREMENTS: OCCUPANCY OF COMPLETED AREAS OF CONSTRUCTION.
D. FOR FF&E (FIXTURES, FURNITURE AND EQUIPMENT) SEE INFORMATION THAT IS PROVIDED BY THE DESIGN AGENCY
END OF SECTION 011000
SECTION 012500 - SUBSTITUTION PROCEDURES
1.1 SECTION INCLUDES
A. PROCEDURAL REQUIREMENTS FOR PROPOSED SUBSTITUTIONS.
1.2 GENERAL REQUIREMENTS
A. SUBSTITUTION REQUEST FORM: CSI FORM13.1A.
B. DOCUMENTATION:
1. JUSTIFICATION.
2. COORDINATION INFORMATION.
3. DETAILED COMPARISON.
4. PRODUCT DATA.
5. SAMPLES.
6. CERTIFICATES AND QUALIFICATION DATA.
7. LIST OF SIMILAR INSTALLATIONS.
8. MATERIAL TEST REPORTS.
9. RESEARCH REPORTS.
10. DETAILED COMPARISON OF CONTRACTOR'S CONSTRUCTION SCHEDULE.
11. COST INFORMATION.
12. CONTRACTOR'S CERTIFICATION.
13. CONTRACTOR'S WAIVER OF RIGHTS TO ADDITIONAL PAYMENT OR TIME.
C. ARCHITECT'S ACTION: IF NECESSARY, ARCHITECT WILL REQUEST ADDITIONAL INFORMATION WITHIN SEVEN DAYS OF RECEIPT OF A REQUEST FOR SUBSTITUTION. ARCHITECT WILL NOTIFY CONTRACTOR OF ACCEPTANCE OR REJECTION WITHIN 15 DAYS OF RECEIPT, OR
SEVEN DAYS OF RECEIPT OF ADDITIONAL INFORMATION.
1.3 SUBSTITUTIONS
A. SUBSTITUTIONS FOR CAUSE: NOT LATER THAN 15 DAYS PRIOR TO TIME REQUIRED FOR PREPARATION AND REVIEW OF SUBMITTALS.
B. SUBSTITUTIONS FOR CONVENIENCE: WILL BE CONSIDERED IF RECEIVED WITHIN 30 DAYS AFTER COMMENCEMENT OF THE WORK.
END OF SECTION 012500
SECTION 012900 - PAYMENT PROCEDURES
1.1 SUMMARY
A. SCHEDULE OF VALUES:
1. PROVIDE MULTIPLE LINE ITEMS FOR PRINCIPAL SUBCONTRACT AMOUNTS IN EXCESS OF FIVE PERCENT OF THE CONTRACT SUM.
2. INCLUDE SEPARATE LINE ITEMS UNDER CONTRACTOR AND PRINCIPAL SUBCONTRACTS FOR PROJECT CLOSEOUT REQUIREMENTS IN AN
AMOUNT TOTALING FIVE PERCENT OF THE CONTRACT SUM AND SUBCONTRACT AMOUNT.
3. UTILIZE DFCM FORM "SCHEDULE OF VALUES".
B. APPLICATIONS FOR PAYMENT:
1. PAYMENT APPLICATION TIMES: INDICATED IN THE AGREEMENT.
2. PAYMENT APPLICATION FORMS: AIA DOCUMENT G702 AND AIA DOCUMENT G703.
3. WAIVER OF MECHANIC'S LIEN: SUBMITTED FROM ENTITIES LAWFULLY ENTITLED TO FILE A LIEN FOR WORK COVERED BY PAYMENT INCLUDING
SUBCONTRACTORS, SUB-SUBCONTRACTORS, AND SUPPLIERS FOR CONSTRUCTION PERIOD COVERED BY PREVIOUS APPLICATION.
END OF SECTION 012900
SECTION 013100 - PROJECT MANAGEMENT AND COORDINATION
1.1 REQUESTS FOR INFORMATION (RFIS)
A. RFI FORMS: USE AIADOCUMENTG716.
B. ARCHITECT'S ACTION: ALLOW SEVEN WORKING DAYS FOR ARCHITECT'S RESPONSE FOR EACH RFI.
C. RFI LOG: MAINTAIN A TABULAR LOG OF RFIS. SUBMIT LOG WEEKLY. USE CSI LOGFORM13.2B.
1.2 PROJECT MEETINGS
A. SCHEDULE AND CONDUCT MEETINGS.
B. PRE-CONSTRUCTION CONFERENCE.
1. PRE-INSTALLATION CONFERENCES: BEFORE EACH CONSTRUCTION ACTIVITY THAT REQUIRES COORDINATION.
C. PROJECT CLOSEOUT CONFERENCE: NO LATER THAN 30 DAYS PRIOR TO THE SCHEDULED DATE OF SUBSTANTIAL COMPLETION.
D. PROGRESS MEETINGS: AT WEEKLY, COORDINATED WITH PREPARATION OF PAYMENT REQUESTS.
E. COORDINATION MEETINGS: AT BIWEEKLY INTERVALS, IN ADDITION TO SPECIFIC MEETINGS HELD FOR OTHER PURPOSES.
END OF SECTION 013100
SECTION 013200 - CONSTRUCTION PROGRESS DOCUMENTATION
1.1 INFORMATIONAL SUBMITTALS
A. FORMAT FOR SUBMITTALS: PDF ELECTRONIC FILE.
B. CONTRACTOR'S CONSTRUCTION SCHEDULE.
C. SPECIAL REPORTS: SUBMIT AT TIME OF UNUSUAL EVENT.
D. UPDATING: AT MONTHLY INTERVALS, ISSUED ONE WEEK BEFORE PROGRESS MEETING.
END OF SECTION 013200
SECTION 013300 - SUBMITTAL PROCEDURES
1.1 PROCEDURES
A. ELECTRONIC COPIES OF DIGITAL DATA FILES OF THE CONTRACT DRAWINGS WILL BE PROVIDED BY ARCHITECT FOR CONTRACTOR'S USE, IF ASKED.
B. PROCESSING TIME:
1. INITIAL REVIEW: 14 DAYS.
2. RE-SUBMITTAL REVIEW: 15 DAYS.
3. CONCURRENT CONSULTANT REVIEW: 14 DAYS.
C. TRANSMITTAL FORM: AIA DOCUMENT G810.
D. SUBMITTAL PROCEDURES:
1. POST PDF FILES DIRECTLY TO ARCHITECT'S FTP SITE.
A. ACTION SUBMITTALS.
B. INFORMATIONAL SUBMITTALS.
C. CERTIFICATES AND CERTIFICATIONS SUBMITTALS: PROVIDE A DIGITAL SIGNATURE ON ELECTRONICALLY SUBMITTED
CERTIFICATES AND CERTIFICATIONS WHERE INDICATED.
D. DELEGATED-DESIGN SERVICES CERTIFICATION: IN ADDITION TO OTHER REQUIRED SUBMITTALS, SUBMIT DIGITALLY SIGNED PDF
ELECTRONIC FILE, SIGNED AND SEALED BY THE RESPONSIBLE DESIGN PROFESSIONAL.
E. CONTRACTOR'S REVIEW:
1. SUBMITTALS: MARKED WITH APPROVAL STAMP BEFORE SUBMITTING TO ARCHITECT.
2. ACTION SUBMITTALS: STAMPED WITH AN ACTION STAMP AND RETURNED.
3. INFORMATIONAL SUBMITTALS: REVIEWED BUT NOT RETURNED, OR REJECTED IF THEY DO NOT COMPLY WITH REQUIREMENTS.
4. INCOMPLETE SUBMITTALS WILL BE RETURNED WITHOUT REVIEW.
5. SUBMITTALS NOT REQUIRED: MAY NOT BE REVIEWED AND MAY BE DISCARDED.
END OF SECTION 01300
SECTION 015000 - TEMPORARY FACILITIES AND CONTROL
1.1 GENERAL
A. FIRE EXTINGUISHERS.
1.2 TEMPORARY UTILITY INSTALLATION
A. PROVIDE ISOLATION OF WORK AREAS IN OCCUPIED FACILITIES WITH NOISE AND DUST CONTROLS.
END OF SECTION 015000
SECTION 015000 - PRODUCT REQUIREMENTS
1.1 PRODUCT SELECTION PROCEDURES
A. PRODUCT SELECTION PROCEDURES:
1. MANUFACTURER/SOURCE: PRODUCT BY MANUFACTURER OR FROM SOURCE NAMED THAT COMPLIES WITH REQUIREMENTS.
2. PRODUCTS: ONE OF THE PRODUCTS LISTED THAT COMPLIES WITH REQUIREMENTS. COMPARABLE PRODUCTS WILL BE CONSIDERED
UNLESS OTHERWISE INDICATED.
3. MANUFACTURERS: PRODUCT BY ONE OF THE MANUFACTURERS LISTED THAT COMPLIES WITH REQUIREMENTS. COMPARABLE
PRODUCTS WILL BE CONSIDERED UNLESS OTHERWISE INDICATED.
4. BASIS-OF-DESIGN PRODUCT: EITHER THE SPECIFIED PRODUCT OR A COMPARABLE PRODUCT BY ONE OF THE OTHER NAMED
MANUFACTURERS.
5. VISUAL MATCHING SPECIFICATION: PRODUCT THAT MATCHES ARCHITECT'S SAMPLE. ARCHITECT'S DECISION WILL BE FINAL.
6. VISUAL SELECTION SPECIFICATION: PRODUCT (AND MANUFACTURER) THAT COMPLIES WITH OTHER SPECIFIED REQUIREMENTS.
ARCHITECT WILL SELECT COLOR, GLOSS,PATTERN, DENSITY, OR TEXTURE FROM MANUFACTURER'S PRODUCT LINE THAT INCLUDES
BOTH STANDARD AND PREMIUM ITEMS.
B. COMPARABLE PRODUCTS
1. CONDITIONS FOR CONSIDERATION:
A. PRODUCT DOES NOT REQUIRE REVISIONS TO THE CONTRACT DOCUMENTS, IS CONSISTENT WITH THE CONTRACT DOCUMENTS AND WILL PRODUCE THE INDICATED RESULTS, AND IS COMPATIBLE WITH OTHER PORTIONS OF THE WORK.
B. COMPARISON OF PROPOSED PRODUCT WITH THOSE NAMED IN THE SPECIFICATIONS.
C. PRODUCT PROVIDES SPECIFIED WARRANTY.
END OF SECTION 016000
SECTION 017300 - EXECUTION
1.1 EXECUTION
A. EXISTING CONDITIONS: EXISTENCE AND LOCATION OF SITE IMPROVEMENTS, UTILITIES, AND OTHER CONSTRUCTION AFFECTING
THE WORK MUST BE INVESTIGATED AND VERIFIED.
1. REVIEW OF THE CONTRACT DOCUMENTS AND FIELD CONDITIONS.
C. PROGRESS CLEANING
1. CLEAN PROJECT SITE AND WORK AREAS DAILY. DISPOSE OF MATERIALS LAWFULLY.
2. KEEP INSTALLED WORK CLEAN.
3. REMOVE DEBRIS FROM CONCEALED SPACES.
D. STARTING AND ADJUSTING
1. START EQUIPMENT AND OPERATING COMPONENTS TO CONFIRM PROPER OPERATION.
2. ADJUST EQUIPMENT FOR PROPER OPERATION.
E. PROTECTION OF INSTALLED CONSTRUCTION
1. PROVIDE FINAL PROTECTION AND MAINTAIN CONDITIONS THAT ENSURE WORK IS WITHOUT DAMAGE.
END OF SECTION 017300
SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL
1.1 SUMMARY
A. RECYCLING NONHAZARDOUS DEMOLITION AND CONSTRUCTION WASTE, TO GREATEST EXTENT PRACTICAL.
B. DISPOSING OF NONHAZARDOUS DEMOLITION AND CONSTRUCTION WASTE.
1.2 WASTE MANAGEMENT PLAN
A. TYPES AND QUANTITIES OF DEMOLITION AND CONSTRUCTION WASTE.
B. TRAIN WORKERS, SUBCONTRACTORS, AND SUPPLIERS ON PROPER WASTE MANAGEMENT PROCEDURES.
C. CONTRACTOR TO TEST EXISTING DOORS FOR ASBESTOS. IF ASBESTOS IS DETECTED, SLCC WILL BE RESPONSIBLE FOR THE REMOVAL AND
DISPOSAL OF THE DOOR.
END OF SECTION 017419
SECTION 017700 - CLOSEOUT PROCEDURES
1.1 SUBSTANTIAL COMPLETION
A. PREPARE AND SUBMIT CONTRACTOR'S LIST OF INCOMPLETE ITEMS (PUNCH LIST) PREPARED ON CSI FORM14.1A.
B. OWNER ADVISED OF PENDING INSURANCE CHANGEOVER.
C. WARRANTIES, MAINTENANCE SERVICE AGREEMENTS, AND SIMILAR DOCUMENTS SUBMITTED.
D. RELEASES, OCCUPANCY PERMITS, AND OPERATING CERTIFICATES SUBMITTED.
E. PROJECT RECORD DOCUMENTS SUBMITTED.
F. TOOLS, SPARE PARTS, AND EXTRA MATERIALS DELIVERED.
G. FINAL CHANGEOVER OF LOCKS PERFORMED.
H. STARTUP TESTING COMPLETED.
I. TEST/ADJUST/BALANCE RECORDS SUBMITTED.
J. TEMPORARY FACILITIES REMOVED.
K. OWNER ADVISED OF HEAT AND UTILITY CHANGEOVER.
L. CHANGEOVER INFORMATION FOR USE, OPERATION, AND MAINTENANCE SUBMITTED.
M. OWNER'S PERSONNEL INSTRUCTED IN OPERATION, ADJUSTMENT, AND MAINTENANCE OF EQUIPMENT AND SYSTEMS.
N. FINAL CLEANING PERFORMED.
O. TOUCH-UP PERFORMED.
P. 10% FINISH MATERIALS MUST BE RESERVED FOR ATTIC STOCK.
1.2 FINAL COMPLETION
A. PRELIMINARY PROCEDURES: BEFORE REQUESTING FINAL INSPECTION, COMPLETE THE FOLLOWING:
B. FINAL APPLICATION FOR PAYMENT SUBMITTED.
C. LIST OF INCOMPLETE ITEMS (PUNCH LIST) ENDORSED BY ARCHITECT AS COMPLETED OR OTHERWISE RESOLVED FOR ACCEPTANCE.
D. EVIDENCE OF CONTINUING INSURANCE COVERAGE SUBMITTED.
E. FINAL PEST-CONTROL INSPECTION REPORT AND WARRANTY SUBMITTED.
1.3 SUBMITTAL OF PROJECT WARRANTIES.
A. PARTIAL OCCUPANCY: SUBMIT WARRANTIES WITHIN 15 DAYS OF COMPLETION OF DESIGNATED PORTIONS OF THE WORK THAT ARE OCCUPIED
OR USED BY OWNER.
B. ORGANIZE WARRANTY DOCUMENTS BASED ON PROJECT MANUAL AND BIND IN HEAVY-DUTY, THREE-RING, VINYL-COVERED, LOOSE-LEAF
BINDERS.
C. SCAN WARRANTIES AND BONDS INTO A SINGLE INDEXED ELECTRONIC PDF FILE.
1.4 O AND M MANUALS.
1.5 FINAL CLEANING
A. CLEAN EACH SURFACE OR UNIT TO CONDITION EXPECTED IN AN AVERAGE COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM.
B. REPLACE DISPOSABLE AIR FILTERS AND CLEAN PERMANENT AIR FILTERS.
C. CLEAN DUCTS, BLOWERS, AND COILS IF UNITS WERE OPERATED WITHOUT FILTERS DURING CONSTRUCTION. CLEAN HVAC SYSTEM IN
COMPLIANCE WITH NADCASTANDARD1992-01.
1.6 REPAIR OF THE WORK
A. REPAIR OR REMOVE AND REPLACE DEFECTIVE CONSTRUCTION. WHERE DAMAGED OR WORN ITEMS CANNOT BE REPAIRED OR RESTORED, PROVIDE REPLACEMENTS. RESTORE DAMAGED CONSTRUCTION AND PERMANENT FACILITIES USED DURING CONSTRUCTION TO SPECIFIED
CONDITION.
END OF SECTION 017700
SECTION 017800 - PROJECT RECORD DOCUMENTS
1.1 RECORD DOCUMENTS
PREPARE AND SUBMIT RECORD DOCUMENTS AS FOLLOWS:
A. ONE SET OF MARKED-UP RECORD PRINTS.
B. RECORD SPECIFICATIONS: ONE PAPER COPY.
C. RECORD PRODUCT DATA: ANNOTATED PDF ELECTRONIC FILES AND DIRECTORIES.
D. MISCELLANEOUS RECORD SUBMITTALS: ANNOTATED PDF ELECTRONIC FILES AND DIRECTORIES.
END OF SECTION 017839
SECTION 092116 - GYPSUM BOARD ASSEMBLIES
1.1 SUMMARY:
A. PERFORMANCE CRITERIA FOR GYPSUM BOARD ASSEMBLIES
B. METAL STUD WALL FRAMING
C. METAL CHANNEL CEILING FRAMING
D. ACOUSTIC INSULATION
E. GYPSUM WALLBOARD
1.2 SUBMITTALS
A. PRODUCT DATA
1.3 PRODUCTS:
A. METAL FRAMING MATERIALS
1. C-SHAPED STUDS W/ KNURLED OR EMBOSSED FACES
2. U-SHAPED RUNNER
3. RESILIENT FURRING CHANNEL
4. PARTITION HEAD TO STRUCTURE CONNECTIONS
B. GYPSUM BOARD MATERIALS
1. GYPSUM WALLBOARD
C. GYPSUM BOARD ACCESSORIES
1. ACOUSTIC INSULATION
A. MINERAL-FIBER
2. BEADS
A. METAL CORNER BEADS (90 DEGREE OUTSIDE CORNERS)
3. JOINT MATERIALS
A. PAPER TAPE
B. JOINT COMPOUND
C. FASTENING SCREWS
1.4 INSTALLATION
A. FRAMING INSTALLATION
B. ACOUSTICAL ACCESSORIES INSTALLATION
C. BOARD INSTALLATION
D. JOINT TREATMENT
END OF SECTION 092116
SECTION 079200 - JOINT SEALANTS
1.1 SUMMARY:
A. PERFORMANCE CRITERIA FOR GYPSUM BOARD ASSEMBLIES
B. METAL STUD WALL FRAMING
C. METAL CHANNEL CEILING FRAMING
D. ACOUSTIC INSULATION
E. GYPSUM WALLBOARD
1.2 SUBMITTALS
A. PRODUCT DATA
1.3 WARRANTY
A. 2 YEAR MANUFACTURER WARRANTY
1.4 PRODUCTS:
A. NON-SAG JOINT SEALANTS
1. ACRYLIC ACOUSTICAL SEALANT
1.5 INSTALLATION
END OF SECTION 079200
SECTION 095100 - ACOUSTICAL CEILINGS
1.1 SUMMARY:
A. SUSPENDED METAL GRID CEILING SYSTEM
B. ACOUSTICAL UNITS
1.2 SUBMITTALS
A. PRODUCT DATA
1.3 PRODUCTS:
A. ACOUSTICAL TILE/PANELS
1. ARMSTRONG
A. CORTEGA SECOND LOOK 2767, 24" X 24", WHITE
1.4 SUSPENSION SYSTEMS
A. METAL GRID SUSPENSION SYSTEM
1.5 INSTALLATION
A. SUSPENSION SYSTEM
END OF SECTION 095100
SECTION 096813 - TILE CARPETING
1.1 SUMMARY:
A. CARPET TILE
1.2 SUBMITTALS
A. PRODUCT DATA
B. SAMPLES
1.3 PRODUCTS:
A. PAINT
1. INTERFACE: SHIVER ME TIMBERS
A. CYPRUS #103923, 25 CM X 1 M
B. ACCESSORIES
1. CARPET TILE ADHESIVE
END OF SECTION 096813
SECTION 096500 - RESILIENT FLOORING
1.1 SUMMARY:
A. RESILIENT BASE
1.2 SUBMITTALS
A. PRODUCT DATA
B. SAMPLES
1.3 PRODUCTS:
A. RESILIENT BASE
1. TARKETT FLOORING
A. JOHNSONITE DC-63-4, 4", BURNT UMBER; COVED
END OF SECTION 096500
SECTION 099123 - INTERIOR PAINTING
1.1 SUMMARY:
A. INTERIOR SURFACES
1.2 SUBMITTALS
A. PRODUCT DATA
B. SAMPLES
1.3 PRODUCTS:
A. PAINT
1. SUPPLIER: PAINT WEST, 1606 3500 S. WEST VALLEY, UT 84119
A. COLOR: SLCC REVUE
END OF SECTION 099123
SECTION 081400 - WOOD DOORS
1.1 SUMMARY:
A. FLUSH WOOD DOORS
B. HOLLOW METAL FRAMES
1.2 SUBMITTALS
A. PRODUCT DATA
1. MUST COMPLY WITH ANSI WDMA I.S.1A-2
B. SHOP DRAWINGS
C. SAMPLES
D. WARRANTY
2.1 PRODUCTS:
A. INTERIOR DOORS
1. SOLID CORE DOORS
A. FINISH: PLAIN SLICED RED OAK, CLEAT LACQUER FINISH
B. EXTRA HEAVY DUTY
2. SOUND RATED DOORS
A. FINISH: PLAIN SLICED RED OAK, CLEAT LACQUER FINISH
B. EXTRA HEAVY DUTY
2.2 ACCESSORIES
A. HOLLOW METAL DOOR FRAMES
1. USE SEMI-GLOSS DTM (DIRECT TO METAL) PAINT
2. MATCH COLOR OF EXISTING DOOR FRAMES WHEN PROJECT IS WITH AN EXISTING BUILDING
3. PAINTED DOOR FRAMES TO BE SPRAY PAINTED WITHIN AN EXISTING BUILDING
B. DOOR WINDOW FRAMES
C. DOOR WINDOW GLAZING
1. CLEAR & TEMPERED
3.1 INSTALLATION
END OF SECTION 099123
SECTION 024100 - DEMOLITION
1.1 SUMMARY:
A. SELECTIVE DEMOLITION
1.2 EXECUTION:
A. DEMOLITION
1. REMOVE ALL ELEMENTS MARKED AS DEMOLISHED AS PER DRAWINGS
2. REMOVE AND PRESERVE ALL ELEMENTS MARKED AS PRESERVE/SALVAGED
1.3 GENERAL PROCEDURES AND PROJECT CONDITIONS
A. COMPLY WITH APPLICABLE CODES & REGULATIONS FOR DEMOLITION OPERATIONS AND FOR SAFETY OF THE EXISTING BUILDING AND PUBLIC.
B. DO NOT BEGIN REMOVAL UNTIL RECEIPT OF NOTIFICATION TO PROCEED FROM OWNER
C. PROTECT EXISTING STRUCTURES AND OTHER ELEMENTS TO REMAIN IN PLACE THAT ARE NOT TO BE REMOVED
D. PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES RECYCLABLE MATERIALS
1.4
END OF SECTION 079200
NO. DATE DESCRIPTION
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
N
INTERIOR ELEVATIONS
EXTERIOR ELEVATIONS
BUILDING SECTIONS
WALL SECTIONS
KEYNOTE
DOOR NUMBER
WALL TYPE
ROOM NAME AND
NUMBER
GLAZING TYPE
DATUM
WINDOW TYPE
CENTER LINE
GRID
PROJECT NORTH (UNO)
CEILING TYPE AND
ELEVATION
DETAIL CALL OUT
ROOM FINISH
1t 10' - 0"
XX
A
XXXX
XX
XXXX
XX
XXXX
XX
XXXX
A2
WALL FINISH
FLOOR FINISH
BASE FINISH
SYMBOLS LEGEND
XX
XXXX
XX
XXXX
? MATERIALXXX
ALTERNATE ROOM
FINISH
WALL FINISHES
FLOOR FINISH
BASE FINISH
AE101
Wx Wx
Wx Wx Fx
Bx
ROOM NAME
DIM TO INSIDE
OF DOOR
FRAME. U.N.O.
DIM TO OUTSIDE
OF WINDOW
FRAME. U.N.O.
DIM TO RIGHT OF
STUD, OR TOP
OF STUD. U.N.O.
DIM TO OUTSIDE
OF DOOR FRAME
AT CONCRETE
AND MASONRY
U.N.O.
FRAMED WALLS
CONC & MASONRY WALLS
DIM TO OUTSIDE
OF WINDOW
FRAME U.N.O.
TYPICAL DIMENSIONING KEYABBREVIATIONS
TILE
OTHERWISE
OR SIDEWALK
SQUARE FOOT
FIRE EXTINGUISHER F.E.C.
OF ARCHITECTS
COEFFICIENT
BOARD
BITUM.
PERPENDICULAR PERP.
MISCELLANEOUS MISC.
INFORMATION INFO.
HYD HYDRANT
EXPANSION JOINT E.J.
CABINET
TOP OF FOOTING T.O.F.
GFGI GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
CONTRACTION JOINT C.T.J.
CONSTRUCTION JOINT C.J.
AIR CONDITIONING
CONTRACTOR INSTALLED
TESTING MATERIALS
ADJ.
A.F.F.
ALUM.
A.S.T.M.
BD.
BLDG.
B.M.
B.O.
BRG.
BTWN.
CER.
CLG.
CLR.
CMU
COL.
CONC.
CONT.
CONST.
COORD.
DBL.
DIA.
DTL.
DWGS.
EA.
ELEV.
EQ.
E.S.
EXIST.
EXPAN.
EXT.
E.W.C.
F.D.
FDN.
F.E.
F.F.
FIN.
FLR.
FTG.
GA.
GALV.
GFCI
GND.
GOVT OR GOV.
GWB.
GYP. BD.
HC.
HDW.
H.M.
HORIZ.
HR.
HT.
HVAC
I.D.
INSUL.
LAV.
LT.
MECH.
MANUF OR MFG.
MIN.
M.O.
MTL.
N.I.C.
NO.
N.T.S.
O.C.
O.D.
O.H.
OPP.
PART.
PL.
PNTD.
P.S.I.
R.D.
RAD.
REINF.
REQ'D
RM.
R.O.
S.D.I.
SHR.
SHT.
SIM.
SPEC.
STC
STD.
STR.
SUSP.
THRU
T.O.
T.O.A.
T.O.C.
T.O.S.
T.O.W.
TYP.
VCT
VERT OR VER.
VEST.
W/
WD.
AT
CENTER LINE
ADJUSTABLE
ABOVE FINISH FLOOR
ALUMINUM
AMERICAN SOCIETY FOR
BITUMINOUS
BUILDING
BENCHMARK
BOTTOM OF
BEARING
BETWEEN
CERAMIC
CEILING
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONTINUOUS
CONSTRUCTION
COORDINATE
DOUBLE
DIAMETER
DETAIL
DRAWINGS
EACH
ELEVATION
EQUAL
EACH SIDE
EXISTING
EXPANSION
EXTERIOR
ELECTRIC WATER COOLER
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FINISH FLOOR
FINISH
FLOOR
FOOTING
GAGE/GAUGE
GALVANIZED
GOVERNMENT FURNISHED
GROUND
GOVERNMENT
GYPSUM WALL BOARD
GYPSUM BOARD
HANDICAPPED
HARDWARE
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
HEATING/VENTILATION/
INSIDE DIAMETER
INSULATION
LAVATORY
LIGHT
MECHANICAL
MANUFACTURER
MINIMUM
MASONRY OPENING
METAL
NOT IN CONTRACT
NUMBER
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OVERHEAD
OPPOSITE
PARTITION
PLATE
PAINTED
POUNDS PER SQUARE INCH
ROOF DRAIN
RADIUS
REINFORCED
REQUIRED
ROOM
ROUGH OPENING
STEEL DECK INSTITUTE
SHOWER
SHEET
SIMILAR
SPECIFICATION
SOUND TRANSMISSION
STANDARD
STRUCTURAL
SUSPENDED
THROUGH
TOP OF
TOP OF ASPHALT
TOP OF CURB
TOP OF SLAB
TOP OF WALL
TYPICAL
VINYL COMPOSITION
VERTICAL
VESTIBULE
WITH
WOOD
MAINTENANCE MAINT.
MAXIMUM MAX.
MATERIAL MAT.
OHD OVERHEAD DOOR
PROTECTION PROT.
SUPER. SUPERVISOR
DIAMETER
DEPARTMENT DEPT
ELEVATION EL.
APPROXIMATE APPROX.
GALLONS PER MINUTE GPM
GALLON GAL.
QTY. QUANTITY
MANUFACTURER MFR.
VENEER VNR.
UNLESS NOTED U.N.O.
B.P. BASE PLATE
A.I.A. AMERICAN INSTITUTE
BOT. BOTTOM
C.P. CAP PLATE
A.B. ANCHOR BOLT
E.F. EACH FACE
O.F. OUTSIDE FACE
I.F. INSIDE FACE 3L THREE LAYERS
P.C.F. POUNDS PER CUBIC FOOT
P.S.F. POUNDS PER
LT. WT. LIGHT WEIGHT
S.J.I. STEEL JOIST INSTITUTE
SCHED. SCHEDULE
M.C.J. MASONRY CONTROL JOINT
ARCH. ARCHITECTURAL
ABV. ABOVE
P.L.F. POUNDS PER LINEAL FOOT
O.W.S.J. OPEN WEB STEEL JOIST
FDTN. FOUNDATION
DET. DETAIL
W.W.F. WELDED WIRE FABRIC
IN. INCHES
FT. FEET
H.S.A. HEADED STUD ANCHOR
D.B.A. DEFORMED BAR ANCHOR
STIFF. STIFFENER
E.W. EACH WAY
L ANGLE
RE: REFERENCE TO
W.A.S. WALL AS SCHEDULED
NUMBER#
O.F.C.I. OWNER FURNISHED CONTRACTOR INSTALLED
O.F.O.I. OWNER FURNITHED OWNER INSTALLED
MATERIAL LEGEND
CONCRETE
MASONRY
STEEL
BATT INSULATION
RIGID INSULATION
FINISH GRADE WOOD /
HARDWOOD
PLYWOOD
SPRAY FOAM INSULATION
DEMOLITION, SHOWN
HIDDEN LINE
WOOD STUD
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/2
2/
:2 6:
P
M GI004
SYMBOLS AND
LEGENDS
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
NO. DATE DESCRIPTION
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
GENERAL DEMO NOTES
GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL
REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS OR
CONFLICT IN THE DRAWINGS BEFORE BEGINNING WORK.
DO NOT SCALE DRAWINGS.
ALL EXISTING ITEMS TO REMAIN SHALL BE PROTECTED DURING DEMOLITION
AND CONSTRUCTION.
ALL ITEMS TO BE REMOVED ARE TO BE DISPOSED OF OFF SITE AT THE
APPROPRIATE FACILITY. ITEMS FOR SALVAGE TO BE STORED ON SITE AND
ADEQUATELY PROTECTED FROM WEATHER AND THEFT.
CONTRACTOR IS TO NOTIFY OWNER PRIOR TO REMOVAL OF ANY FIXTURES.
ALL MECHANICAL, PLUMBING AND ELECTRICAL FIXTURES AND RELATED ROUGH-
INS ARE TO BE REMOVED AT AFFECTED AREAS TO NEAREST WALL FOR
REROUTING.
CONTRACTOR TO VERIFY ALL UTILITIES PRIOR TO REMOVAL FOR MOST
ECONOMICAL PATHWAY.
CONTRACTOR IS TO PROVIDE THE OWNER WITH 24 HOURS ADVANCE NOTICE
PRIOR TO ANY UTILITY SHUT-DOWNS OR DISCONNECTS.
ALL UTILITIES ARE TO BE IDENTIFIED AND THEIR LOCATIONS CLEARLY MARKED
BY QUALIFIED ENTITIES PRIOR TO DEMOLITION AND/OR CONSTRUCTION.
ANY STRUCTURAL WALLS TO BE REMOVED ARE TO HAVE THE REMAINDER OF
THE WALLS PROPERLY SHORED UNTIL NEW STRUCTURE IS IN PLACE.
ANY FLOORING OR FLOOR STRUCTURE TO BE REMOVED IS TO HAVE
REMAINDER OF FLOORING OR FLOOR STRUCTURE PROPERLY SHORED UNTIL
NEW STRUCTURE IS IN PLACE.
PATCH AND REPAIR ANY DAMAGE DONE DURING DEMO PHASE. ALL EXISTING
WALL FINISHES TO BE AS SCHEDULED.
TEST DEMOLISHED DOORS FOR ASBESTOS. IF ASBESTOS IS PRESENT. OWNER
SHALL BE RESPONSIBLE COST OF DISPOSAL.
C
D
E
F
11 12 13
033B-A
TESTING LAB
033E
DOUBLE
OFFICE
033D
IT OFFICE
TESTING
CENTER
033B
OBSERVATION
HALLWAY 033F
WORKROOM
033G
DIRECTOR
OFFICE
033A
GED TESTING
001F
HALLWAY
001A
HALLWAY
2.03
CLASSROOM
C
D
E
F
11 12 13
033B-A
TESTING LAB
033E
DOUBLE
OFFICE
033D
IT OFFICE
TESTING
CENTER
033B
OBSERVATION
HALLWAY
033F
WORKROOM
033G
DIRECTOR
OFFICE
033A
GED TESTING
001F
HALLWAY
001A
HALLWAY
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
CLASSROOM
EXIST
9' - 4"
DEMO CEILING LEGEND
DEMO EXISTING LAY-IN GRID CEILING
EXISTING LAY-IN GRID CEILING TO REMAIN.
RETURN GRILL
LIGHTING
PROJECTOR
COMMUNICATION DEVICE(S)
EXIT SIGN
SECURITY CAMERA
DEMO FLOOR LEGEND
WALL TO BE REMOVED, FULL
HEIGHT
WALL TO REMAIN
DOOR AND FRAME TO BE
REMOVED, UNLESS OTHERWISE
NOTED
DOOR AND FRAME TO REMAIN
WINDOW AND FRAME TO BE REMOVED
FLOOR TO BE DEMOLISHED
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/2
2/
:2 6:
P
M AD100
LEVEL 0 RM 020
DEMO FLOOR &
RCP PLAN
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
1/8" = 1'-0"AD100
A1 RM 020 ENLARGED DEMO PLAN
1/8" = 1'-0"AD100
A3
RM 020 ENLARGED DEMO REFLECTED CEILING
PLAN
KEYNOTES
2.03 REMOVE AND PRESERVE DOOR FOR FUTURE REINSTALLATION AT LOCATION
INDICATED
N
NO. DATE DESCRIPTION
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
GENERAL DEMO NOTES
GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL
REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS OR
CONFLICT IN THE DRAWINGS BEFORE BEGINNING WORK.
DO NOT SCALE DRAWINGS.
ALL EXISTING ITEMS TO REMAIN SHALL BE PROTECTED DURING DEMOLITION
AND CONSTRUCTION.
ALL ITEMS TO BE REMOVED ARE TO BE DISPOSED OF OFF SITE AT THE
APPROPRIATE FACILITY. ITEMS FOR SALVAGE TO BE STORED ON SITE AND
ADEQUATELY PROTECTED FROM WEATHER AND THEFT.
CONTRACTOR IS TO NOTIFY OWNER PRIOR TO REMOVAL OF ANY FIXTURES.
ALL MECHANICAL, PLUMBING AND ELECTRICAL FIXTURES AND RELATED ROUGH-
INS ARE TO BE REMOVED AT AFFECTED AREAS TO NEAREST WALL FOR
REROUTING.
CONTRACTOR TO VERIFY ALL UTILITIES PRIOR TO REMOVAL FOR MOST
ECONOMICAL PATHWAY.
CONTRACTOR IS TO PROVIDE THE OWNER WITH 24 HOURS ADVANCE NOTICE
PRIOR TO ANY UTILITY SHUT-DOWNS OR DISCONNECTS.
ALL UTILITIES ARE TO BE IDENTIFIED AND THEIR LOCATIONS CLEARLY MARKED
BY QUALIFIED ENTITIES PRIOR TO DEMOLITION AND/OR CONSTRUCTION.
ANY STRUCTURAL WALLS TO BE REMOVED ARE TO HAVE THE REMAINDER OF
THE WALLS PROPERLY SHORED UNTIL NEW STRUCTURE IS IN PLACE.
ANY FLOORING OR FLOOR STRUCTURE TO BE REMOVED IS TO HAVE
REMAINDER OF FLOORING OR FLOOR STRUCTURE PROPERLY SHORED UNTIL
NEW STRUCTURE IS IN PLACE.
PATCH AND REPAIR ANY DAMAGE DONE DURING DEMO PHASE. ALL EXISTING
WALL FINISHES TO BE AS SCHEDULED.
TEST DEMOLISHED DOORS FOR ASBESTOS. IF ASBESTOS IS PRESENT. OWNER
SHALL BE RESPONSIBLE COST OF DISPOSAL.
DEMO CEILING LEGEND
DEMO EXISTING LAY-IN GRID CEILING
EXISTING LAY-IN GRID CEILING TO REMAIN.
RETURN GRILL
LIGHTING
PROJECTOR
COMMUNICATION DEVICE(S)
EXIT SIGN
SECURITY CAMERA
DEMO FLOOR LEGEND
WALL TO BE REMOVED, FULL
HEIGHT
WALL TO REMAIN
DOOR AND FRAME TO BE
REMOVED, UNLESS OTHERWISE
NOTED
DOOR AND FRAME TO REMAIN
WINDOW AND FRAME TO BE REMOVED
FLOOR TO BE DEMOLISHED
A
B
C
2 3 4
CLASSROOM
090B
STORAGE
WOMEN RR
001C
HALLWAY
001B
HALLWAY
S005
STAIRS
2.02
2.05
2.05
A
B
C
2 3 4
CLASSROOM
090B
STORAGE
WOMEN RR
001C
HALLWAY
001B
HALLWAY
S005
STAIRS
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
2.01
2.04
1/8" = 1'-0"AD101
A1 RM 090 ENLARGED DEMO PLAN
1/8" = 1'-0"AD101
A3
RM 090 ENLARGED DEMO REFLECTED CEILING
PLAN
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/2
2/
:2 6:
P
M AD101
LEVEL 0 RM 090
DEMO FLOOR &
RCP PLAN
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
3KEYNOTES
2.01 REMOVE AND PRESERVE GRID PANELS FOR FUTURE REINSTALLATION
2.02 REMOVE WHOLE WALL PANELS TO THE NEAREST JOINT EAST OF GRID LINE 2
2.04 REMOVE GRID PANELS WHERE NESSESSARY FOR CONSTRUCTION OF NEW
WALL
2.05 REMOVE AND PRESERVE WHITEBOARD. RETURN TO OWNER.
N
NO. DATE DESCRIPTION
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
CEILING LEGEND
RETURN GRILL
EXISTING ACOUSTICAL CEILING TILE
2'x2' ACOUSTICAL CEILING TILE C1 X'-X"
EXIST
X'-X"
SUPPLY DIFFUSER
LIGHTING
FIRE SPRINKLERS & ALARM
MOTION SENSORS
SPEAKERS
PROJECTOR
COMMUNICATION DEVICE(S)
EXIT SIGN
WALL MOUNTED PROJECTOR SCREEN
A
B
C
2 3 4
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
CLASSROOM
090B
STORAGE
090C
CLASSROOM
WOMEN RR
001C
HALLWAY
001B
HALLWAY
S005
STAIRS
CL1
9' - 4"
9.01
9.03
A
B
C
2 3 4
CLASSROOM
090B
STORAGE
090C
CLASSROOM
WOMEN RR
001C
HALLWAY
001B
HALLWAY
S005
STAIRS
A2
A1
9.02
9.02
AE100E1
AE100
C2
D1
D2
E2
B1
B2
C1
090C
4'
1/
8"
39' - 5 3/4" +/-
TYP.
9.02
9.04
TYP.
9.06
TYP.
9.07
TYP.
9.02
9.04
TYP.
9.06
3'
0"
1' - 0"1' - 0"
TYP.
9.07
9.05
GENERAL PLAN NOTES
GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL
REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS OR
CONFLICT IN THE DRAWINGS BEFORE BEGINNING WORK.
DO NOT SCALE DRAWINGS.
FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S
STANDARD DETAILS OR APPROVED SHOP DRAWINGS / DATA SHEETS IN
ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
AT DEMOLISHED & NEWLY CONSTRUCTED WALLS, PATCH & REPAIR CEILING
GRID SYSTEM.
FURNITURE LAYOUT IS PROVIDED AS A CONCEPTUAL LAYOUT. FURNITURE NOT
INCLUDED IN CONTRACT.
INCLUDE AN ALLOWANCE IN THE BID FOR (20) TILES IN ROOM 020 AND (40) TILES
IN ROOM 090.
OWNER IS PROVIDING & INSTALLING SIGNAGE
CLASSROOM
CPT1 BR1
P1 C1
090B
STORAGE
CLASSROOM
090C
CPT1 BR1
P1 C1
WOMEN RR
001C
HALLWAY
001B
HALLWAY
S005
STAIRS
FINISH LEGEND
EXISTING FLOORING TO REMAIN
CARPET
EXT
CPT1
TILE
Fx
OPEN GRATE CAT WALK
Fx(NO ADDITIONAL FINISH)
T1 TRANSITION
FINISH KEY LEGEND
Fx: FLOOR FINISH Bx: BASE MATERIAL / FINISH Wx: WALL FINISH Cx: CEILING FINISH Wx: PLAN TOP WALL FINISH Wx: PLAN RIGHT WALL FINISH Wx: PLAN BOTTOM WALL FINISH Wx: PLAN LEFT WALL FINISH
Fx Bx
Wx Cx
ROOM FINISH TAG
ROOM NAME
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/2
2/
:2 6:
P
M AE100
LEVEL 0 RM 090
FLOOR, FINISH &
RCP PLANS
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
KEYNOTES
9.01 REUSE PREVIOUSLY REMOVED & PRESERVED GRID PANELS. MATCH NEW
GRID TO EXISTING.
9.02 OWNER FURNISHED, CONTRACTOR INSTALLED 8' X 4' WHITE BOARD.
CENTER ON WALL
9.03 PROJECTOR
9.04 ROLLER PROJECTOR SCREEN
9.05 CORK BOARD (EXISTING)
9.06 WALL BASE
9.07 PATCH ALL AREAS AFFECTED BY ELECTRICAL WORK. PAINT TO MATCH
1/8" = 1'-0"AE100
A1 RM 090 ENLARGED FLOOR PLAN
1/8" = 1'-0"AE100
A4 RM 090 ENLARGED REFLECTED CEILING PLAN
N
1/4" = 1'-0"AE100
E1 RM 090 - WEST
1/4" = 1'-0"AE100
C2 RM 090C - NORTH
1/4" = 1'-0"AE100
D1 RM 090 - EAST
1/4" = 1'-0"AE100
E2 RM 090 - NORTH
1/4" = 1'-0"AE100
D2 RM 090 - SOUTH
1/4" = 1'-0"AE100
B1 RM 090C - EAST
1/4" = 1'-0"AE100
B2 RM 090C - SOUTH
1/4" = 1'-0"AE100
C1 RM 090C - WEST
1/8" = 1'-0"AE100
A3 RM 090 ENLARGED FINISH FLOOR PLAN
NO. DATE DESCRIPTION
KEYNOTES APPLY TO ALL ELEVATIONS OF ROOM 090C
KEYNOTES APPLY TO ALL ELEVATIONS OF ROOM 090
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
GENERAL PLAN NOTES
GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND SHALL
REPORT TO THE ARCHITECT ANY UNKNOWN CONDITIONS, ERRORS OR
CONFLICT IN THE DRAWINGS BEFORE BEGINNING WORK.
DO NOT SCALE DRAWINGS.
FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S
STANDARD DETAILS OR APPROVED SHOP DRAWINGS / DATA SHEETS IN
ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
AT DEMOLISHED & NEWLY CONSTRUCTED WALLS, PATCH & REPAIR CEILING
GRID SYSTEM.
FURNITURE LAYOUT IS PROVIDED AS A CONCEPTUAL LAYOUT. FURNITURE NOT
INCLUDED IN CONTRACT.
INCLUDE AN ALLOWANCE IN THE BID FOR (20) TILES IN ROOM 020 AND (40) TILES
IN ROOM 090.
OWNER IS PROVIDING & INSTALLING SIGNAGE
C
D
E
F
G
H
11 12 13
033B-A
TESTING LAB
033E
DOUBLE
OFFICE
033D
IT OFFICE
TESTING
CENTER
CLASSROOM
033B
OBSERVATION
HALLWAY
033F
WORKROOM
033G
DIRECTOR
OFFICE
033H
ADVISOR
OFFICE
033A
GED TESTING
001F
HALLWAY
001A
HALLWAY
RECEPTION
033G
9.02 AE101 D1
D2
E1
E2
HALLWAY
C
D
E
F
11 12 13
033B-A
TESTING LAB
033E
DOUBLE
OFFICE
033D
IT OFFICE
TESTING
CENTER
CLASSROOM
033B
OBSERVATION
HALLWAY
033F
WORKROOM
033G
DIRECTOR
OFFICE
033A
GED TESTING
001F
HALLWAY
001A
HALLWAY
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
EXIST
9' - 4"
TYP.
9.02
TYP.
9.06
9.07
2' - 9" 6' - 0" 6' - 0" 6' - 0" 10' - 7" 7' - 3"
3' - 2 3/4"6' - 0"6' - 0"6' - 0"6' - 0"4' - 1 3/4"
CEILING LEGEND
RETURN GRILL
EXISTING ACOUSTICAL CEILING TILE
2'x2' ACOUSTICAL CEILING TILE C1 X'-X"
EXIST
X'-X"
SUPPLY DIFFUSER
LIGHTING
FIRE SPRINKLERS & ALARM
MOTION SENSORS
SPEAKERS
PROJECTOR
COMMUNICATION DEVICE(S)
EXIT SIGN
WALL MOUNTED PROJECTOR SCREEN
033B-A
TESTING LAB
033E
DOUBLE
OFFICE
033D
IT OFFICE
TESTING
CENTER
EXT BR1
P1 C1
CLASSROOM
033B
OBSERVATION
HALLWAY
033F
WORKROOM
033G
DIRECTOR
OFFICE
033H
ADVISOR
OFFICE
033A
GED TESTING
001F
HALLWAY
001A
HALLWAY
RECEPTION
HALLWAY
FINISH LEGEND
EXISTING FLOORING TO REMAIN
CARPET
EXT
CPT1
TILE
Fx
OPEN GRATE CAT WALK
Fx(NO ADDITIONAL FINISH)
T1 TRANSITION
FINISH KEY LEGEND
Fx: FLOOR FINISH Bx: BASE MATERIAL / FINISH Wx: WALL FINISH Cx: CEILING FINISH Wx: PLAN TOP WALL FINISH Wx: PLAN RIGHT WALL FINISH Wx: PLAN BOTTOM WALL FINISH Wx: PLAN LEFT WALL FINISH
Fx Bx
Wx Cx
ROOM FINISH TAG
ROOM NAME
N
KEYNOTES
9.02 OWNER FURNISHED, CONTRACTOR INSTALLED 8' X 4' WHITE BOARD. CENTER
ON WALL
9.06 WALL BASE
9.07 PATCH ALL AREAS AFFECTED BY ELECTRICAL WORK. PAINT TO MATCH
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/2
2/
:2 6:
P
M AE101
LEVEL 0 RM 020
FLOOR, FINISH &
RCP PLANS
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
1/8" = 1'-0"AE101
A1 RM 020 ENLARGED FLOOR PLAN
1/8" = 1'-0"AE101
A4 RM 020 ENLARGED REFLECTED CEILING PLAN
1/4" = 1'-0"AE101
D1 RM 020 - EAST
1/4" = 1'-0"AE101
E1 RM 020 - WEST
1/4" = 1'-0"AE101
D2 RM 020 - SOUTH
1/4" = 1'-0"AE101
E2 RM 020 - NORTH
1/8" = 1'-0"AE101
A3 RM 020 ENLARGED FINISH FLOOR PLAN
NO. DATE DESCRIPTIONKEYNOTES APPLY TO ALL ELEVATIONS OF ROOM 020
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
2' o.c.3_ 4"
7/8" 3_ 4"
8" MAX.
7/8" 7/8"
Unattached Wall
Attached Wall
Unattached W all
B or P B
B
B
B
B
B
B
B
BBB
UNATTACHED
WALL
ATTACHED
WALL
B or P B or P
1-1/2"
TOTAL
TRAVEL
OPTIONAL
ATTACHED
WALL
POP RIVETSCREW TIGHTENED THROUGH MAIN
RUNNER WEB RESTRICTING
SEPARATION FRM WALL MOLDING
SEISMIC CLIPS OR POP RIVETS
8" MAX.
8" MAX.
PERIMETER WIRE 48" O.C.
& WITHIN 8" OF WALL
° M
AX
45° M
AX
45° MAX45
° M
AX
MAIN RUNNER
CROSS RUNNER
2" MIN. 2" MIN.
(4) #12 GAGE WIRES SECURED TO MAIN
RUNNER WITHIN 2" OF CROSS RUNNER
INTERSECTION & SPLAYED 90 DEGREES
FROM EACH OTHER AT ANGLE NOT
EXCEEDING 45 DEGREES FROM
HORIZONTAL PLANE OF CEILING.
COMPRESSION STRUT FROM THE
MAIN RUNNER TO THE
STRUCTURE ABOVE.
1.
2.
3.
4.
NOTES:
HEAVY DUTY GRID
ELECTRICAL OR OTHER FIXTURES SHALL NOT BE
DESIGNED TO COMPROMISE CEILING PERMFORMANCE
WIRES TIES SHALL HAVE NO LESS THAN 3 TURNS
CEILING DESIGN & INSTALLATION SHALL COMPLY WITH ASCE
7 CURRENT EDITION
5/
8" TY
P
5/ 8"
1"
J-MOLD TRIM
LONG-LEG SLIP
TRACK
ACOUSTIC BATT
INSULATION
CAULK
METAL DECK
PAINT-ABLE CAULK
ALL AROUND
PAINTED HOLLOW MTL. DOOR &
ANCHORED W/ MASONRY
ANCHORS
DOOR AS SCHEDULED
PLASTER
EXISTING CMU
EXISTING CMU
PAINT-ABLE CAULK ALL
AROUND
PAINTED HOLLOW MTL. DOOR
FRAME MINERAL WOOL
FILLED & ANCHORED W/
MASONRY ANCHORS
PLASTER
- V
IF
7"
DOOR TYPES
B
1T
FRAME TYPES
A5
AE501
A4
AE501
SOLID CORE WOOD STAIN
STANDARD NARROW LIGHT
2"x X HM FRAME.
PAINT: DRF1
SE
E
SC
H
2"
2" SEE SCH 2"
A
(EXISTING) SOLID CORE
WOOD DOOR
5/8" GYP. BD.
6" 20 GA. METAL STUD @ 16" O.C.
FIRE TEST:
SOUND TEST:
FIRE RATING:
STC RATING:
WALL HEIGHT:
A2 N/A
UL: V438, U465
STC-53
TO DECK
SOUND BATT
INSULATION.
RC-1
5/8" GYP. BD.
3 5/8" 20 GA. METAL STUD @ 16" O.C.
FIRE TEST:
SOUND TEST:
FIRE RATING:
STC RATING:
WALL HEIGHT:
A1 N/A
NGC 2018106
STC-46
6" ABOVE WALL
SOUND BATT
INSULATION.
LAY-IN ACOUSTIC PANEL
SUSPENSION WIRE TO
STRUCTURE
CL1
DOOR JAMB
DOOR STOP
ESD VINYL TILE
DOOR PER SCHEDULE,
WHERE OCCURS
TYP CARPET REDUCER TRANSITION
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/2
2/
:2 6:
P
M AE501
WALL & DOOR
TYPE,
SCHEDULES &
DETAILS
25-027
BID SET 2025-12-19
SL
C
C R
M
R
EM
O D
EL
C
O M
M U
N
IT
Y
BL
VD
TA
YL
O
R
SV
IL
LE
, U T
DOOR SCHEDULE
DOOR # SIZE DOOR TYPE FRAME TYPE HARDWARE GROUP COMMENTSWIDTH HEIGHT THICKNESS
020 3' - 0" 7' - 0" 1 3/4" B A CLASSROOM SET
033G 3' - 0" 7' - 0" 1 3/4" A A CLASSROOM SET PREVIOUSLY SALVAGED DOOR FROM RM 020
090 3' - 0" 7' - 0" 1 3/4" B A CLASSROOM SET
090C 3' - 0" 7' - 0" 1 3/4" B A CLASSROOM SET
1/2" = 1'-0"AE501
A1 LAY-IN CEILING SEISMIC BRACING
3" = 1'-0"AE501
B4 STC 50 WALL DEFLECTION TRACK
3" = 1'-0"AE501
A4 HM DOOR HEAD - INTERIOR WALL
3" = 1'-0"AE501
A5 HM DOOR JAMB - INTERIOR WALL
FINISH LEGEND
KEY DESCRIPTION MANUFACTURER STYLE/PATTERN COLOR/FINISH SIZE NOTES
BASE FINISHES
BR1 RUBBER BASE JOHNSONITE JOHNSONITE DC-63-4 BURNT UMBER 4" COVED.
EXT EXISTING TO REMAIN
CEILING
C1 ACT ARMSTRONG CORTEGA SECOND LOOK 2767 WHITE 24" X 24" X 3/4"
EXT EXISTING TO REMAIN
DOOR FRAME FINISH
DRF1 PAINT PAINT WEST SLCC CONSTRUCTION TRADE DOOR FRAMES
FLOOR FINISHES
CPT1 CARPET TILE INTERFACE SHIVER ME TIMBERS CYPRUS #103923 25 CM X 1 M INSTALL ASHLAR
EXT EXISTING TO REMAIN
T2 TRANSITION GENOTEK REDUCER STAINLESS #530
WALL FINISHES
EXT PAINT PAINT WEST SLCC REVUE
P1 EXISTING TO REMAIN
NO. DATE DESCRIPTION
6" = 1'-0"AE501
E1 T1 TRANSITION
REVIEWED FOR CODE
COMPLIANCE
BY: _____________________
DATE: ______________01/12/2026
The plan review performed is limited to the contents of these plans. Any errors or omissions contained herein shall not be construed as permission to allow conditions to exist in violation of the codes and ordinances adopted by jurisdiction.
SD
A
M101
A
M-101
T
12/12 CD-1
(2) 200
DUCTWORK/GRILLES PIPING PLUMBING LINETYPES LINETYPES CONT.
N
LB/HR.GPM
12ø 4'-0"(1) - 1" SLOTS
L-1 200 CFM (RADIUS)
W R
12/12
45° D
FD
FSD
SD
OR
8/8
1.25D
AD
12/8 FO
ATC
CF
AW
AV
HP(NAME)
N20
(NAME)
R
12/8
12ø
UP
DN
12/12 12ø
1.5D
D
12∅ 12/12
HFR
HFS
FOR
FOS
HG
(NAME)
LPG
G(NAME)
GHR
HWR
HWS
E(NAME)
G
MUW
BF
BBD
HPS
MPS
LPS
HPC
LPC
P-1
OX
MA
MA 120
MV
N
C02
CA
LA
LV
B
CR
CS
CHWR
CHWS
IA
IA 120
MPC
BDD
SW
OX 120
RS
RL
V
RDO
RD
ROR
F
DI
DIR
RO
FOV
S
T
S
RPBP
THERMOSTATIC MIXING VALVE
REDUCED PRESSURE BACKFLOW
PREVENTOR W/ DRAIN PAN
FUEL OIL VENT
REVERSE OSMOSIS WATER SUPPLY
DEIONIZED WATER RETURN
DEIONIZED WATER SUPPLY
RISE OR DROP
FIRE SPRINKLER WATER
DRAIN PAN AND P-TRAP
FILL PORT
VALVE IN RISE
PRESSURE REDUCING VALVE SELF CONTAINED
COTG
FCO
MEDICAL OXYGEN AT PRESSURE
INDICATED
REVERSE OSMOSIS WATER RETURN
SOFT DOMESTIC WATER
VENT (SEWER)
SEWER (ABOVE GRADE)
SEWER (BELOW GRADE)
ROOF DRAIN OVERFLOW
ROOF DRAIN
VACUUM
PUMPED CONDENSATE
REFRIGERANT LIQUID
REFRIGERANT SUCTION
UNIT HEATER
DUCT SMOKE DETECTOR
3-WAY BLOW
PATTERN
2-WAY BLOW
PATTERN
1-WAY BLOW PATTERN
NEGATIVE PRESSURE DUCT - RISE
POSITIVE PRESSURE DUCT - DROP
POSITIVE PRESSURE DUCT - RISE
BACK DRAFT DAMPER
CEILING RETURN AIR GRILE
W/ SOUND BOOT
DOWNSPOUT NOZZLE
ROOF DRAIN
SENSOR
THERMOSTAT
SWITCH
HOSE BIBB
AIR VENT-AUTO
AIR VENT-MANUAL
FLOOR DRAIN
FLOOR SINK
SPRINKLER HEAD
FIRE RISER
BRANCH - TOP CONNECTION
BRANCH - BOTTOM CONNECTION
MEDIUM PRESSURE CONDENSATE
INSTRUMENT AIR AT PRESSURE
INDICATED
INSTRUMENT AIR
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
FIXTURE FROM LEVEL ABOVE
BRINE
LAB VACUUM
LAB AIR
COMPRESSED AIR
CARBON DIOXIDE
NITROUS OXIDE
NITROGEN
MEDICAL VACUUM
MEDICAL AIR AT PRESSURE INDICATED
MEDICAL AIR
MEDICAL OXYGEN
HIGH PRESSURE DOMESTIC WATER
ACID VENT
ACID WASTE
KEYED NOTE IDENTIFICATION
EQUIPMENT IDENTIFICATION
DETAIL TAG - TOP FIGURE IS DETAIL NO.
BOTTOM FIGURE IS SHEET NO.
SECTION TAG - TOP FIGURE IS SECTION NO.
BOTTOM FIGURE IS SHEET NO.
POINT OF CONNECTION
PLUMBING
FIXTURES
DOMESTIC HOT WATER RETURN
(DHWR)
DOMESTIC HOT WATER (DHW)
DOMESTIC COLD WATER (DCW)
FLOOR CLEAN-OUT
OR CLEAN-OUT TO
GRADE
HOSE
VALVE
FLOW SWITCH
NRS GATE VALVE WITH
SUPERVISION
BRANCH - SIDE CONNECTION
RISER - UP (ELBOW)
RISER - DOWN (ELBOW)
ARROW INDICATES DIRECTION OF FLOW IN
PIPE
NIGHT THERMOSTAT
45° ELBOW
90° ELBOW
CALIBRATED BALANCING
VALVE WITH GPM INDICATED
GLOBE VALVE
CHECK VALVE
GATE VALVE
RELIEF VALVE
ANGLE VALVE
PRESSURE REDUCING VALVE EXTERNAL PRESSURE
SOLENOID VALVE
FLOW SWITCH
REDUCER
LOW PRESSURE CONDENSATE
HIGH PRESSURE CONDENSATE
LOW PRESSURE STEAM
MEDIUM PRESSURE STEAM
HIGH PRESSURE STEAM
BOILER BLOW DOWN
BOILER FEED WATER
MAKE UP WATER
NATURAL GAS
EXISTING PIPING
HEATING HOT WATER SUPPLY
HEATING HOT WATER RETURN
GLYCOL HEAT RECOVERY PIPING
GLYCOL PIPING SOLUTION
LIQUIFIED PETROLEUM GAS
EXISTING PIPING TO BE
REMOVED
HOT GAS
FUEL OIL SUPPLY
FUEL OIL RETURN
HELICOPTER FUEL SUPPLY
HELICOPTER FUEL RETURN
CHEMICAL FEED
DEMOLITION
TOP
FIGURES INDICATE
NECK SIZE AND TYPE.
BOTTOM
FIGURE INDICATES
QUANTITY AND CFM.
NEGATIVE PRESSURE DUCT - DROP
ROUND DUCT - RISE
ROUND DUCT - DROP
UNDER FLOOR DUCT
TURNING VANES
FRESH AIR LOUVER
RELIEF AIR OR EXHAUST AIR LOUVER
CEILING SUPPLY DIFFUSER
CEILING RETURN REGISTER
CEILING EXHAUST REGISTER,
(BALANCE TO MATCH SUPPLY IF
RETURN CFM IS NOT SHOWN)
SIDEWALL SUPPLY
REGISTER
SIDEWALL EXHAUST OR
RETURN REGISTER
CEILING SUPPLY DIFFUSER
WITH FLEXIBLE DUCT
CEILING AIR GRILLE WITH
FLEXIBLE DUCT
LINEAR DIFFUSER WITH PLENUM AND FLEXIBLE
DUCT CONNECTION. TOP : DUCT SIZE, ACTIVE
LENGTH, NO. OF SLOTS & SIZE OF SLOT.
BOTTOM: TYPE , CFM, RADIUS (IF APPLICABLE).
FLEXIBLE DUCT CONNECTION
FLEXIBLE DUCT
FLAT OVAL DUCT WITH NET INSIDE
DIMENSIONS SHOWN IN INCHES.
RECTANGULAR DUCT WITH NET INSIDE
DIMENSIONS SHOWN IN INCHES.
ROUND DUCT WITH NET INSIDE DIMENSIONS
SHOWN IN INCHES.
WITH RESPECT TO AIR FLOW 15°
NOMINAL INCLINE WITH RADIUS
TURNS=DEPTH OF DUCT.
INCLINED RISE
INCLINED DROP
R/W=1. ROUND DUCT SIMILAR TO RECTANGULAR
RECTANGULAR TO RECTANGULAR OR ROUND TO ROUND
DUCT TRANSFORMATION MAXIMUM 15° INCLUDED ANGLE
EXCEPT WHERE SHOWN OTHERWISE.
RECTANGULAR TO ROUND DUCT TRANSFORMATION
BRANCH DUCT SPLIT WITH 6" WIDTH AND MIN.
R=WIDTH OF BRANCH DUCT DOWNSTREAM.
ELBOW TURNING VANE OPTIONAL.
TAP ENTRY AREA EQUALS 150% OF BRANCH AREA
HIGH EFFICIENCY FITTING
MANUAL VOLUME DAMPER
FIRE DAMPER IN DUCT, W/ ACCESS PANEL REQD.
COMBINATION FIRE/SMOKE DAMPER W/ ACCESS PANEL
SMOKE DAMPER W/ ACCESS PANEL
ATC DAMPER
ACCESS PANEL IN DUCT OR PLENUM
HEATING OR COOLING COIL IN DUCT
SINGLE DUCT AIR TERMINAL BOX VARIABLE OR
CONSTANT VOLUME. MIN. 1-1/2 TERMINAL INLET
SIZE STRAIGHT DUCT AT TERMINAL INLET.
LATERAL STRAINER WITH BLOW-OFF VALVE,
PROVIDE HOSE END WITH CAP WHERE DISCHARGE
IS NOT PIPED TO DRAIN
LEGEND OF MECHANICAL SYMBOLS AND ABBREVIATIONS
SHUT OFF VALVE
BALL VALVE
BUTTERFLY VALVE
MOTOR OPERATED BUTTERFLY VALVE
GATE VALVE - NON RISING STEM
PLUG VALVE
ATC - 2 WAY VALVE
ATC - 3 WAY VALVE
S
F&T=FLOAT & THERMOSTATIC
VENTURI FLOW METER
FLOW METER ORIFICE
PS
PRESSURE SWITCH
TEMPERATURE AND PRESSURE
TEST PORT
THERMOMETER WELL
THERMOMETER - TEMP RANGE AS INDICATED
PRESSURE GAUGE WITH
SHUT OFF PLUG VALVE
-1
F
PRESSURE GAUGE WITH PIGTAIL
UNION
FLANGE
ECCENTRIC REDUCER
PIPE CAP
SHUT OFF PLUG VALVE FOR
FOR USE WITH PRESSURE GAUGE
DN
LEADER INDICATES DOWNWORD SLOPE
FLEXIBLE EXPANSION JOINT
ALIGNMENT GUIDE
ANCHOR
VTR
WATER HAMMER ARRESTOR
VENT THRU ROOF
CLEAN-OUT
ANNOTATIONS
FIRE
EQUIPMENT
INLINE PUMP
FAN
INLINE PUMP
ICW
IHW
ISCW
IHWR
INDUSTRIAL SOFT COLD WATER
INDUSTRIAL HOT WATER RETURN
INDUSTRIAL HOT WATER
INDUSTRIAL COLD WATER
LW
LWR
LAB WATER
LAB WATER RETURN
TW
TWR TEMPERED WATER RETURN
TEMPERED WATER
FVS FLUSH VALVE SUPPLY
PC
GPM0.0
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
WIDTH X HEIGHT
R.A. LOUVER
WIDTH X HEIGHT
O.A. LOUVER
12/12 RG-1
(2) 200
12/12 EG-1
(2) 200
12/12 SWS-1
(2) 200
12/12 SWR-1
(2) 200
12/12 CD-1
(2) 200
12/12 RG-1
(2) 200
2-WAY BLOW
PATTERN
4-WAY BLOW
PATTERN
F&T
A
L I C
E N
S E
D
P
ROFESS IONA
L
E N
G I N
E E
R
No. 8325442-2202
S
T A
T E OF U
TA
H
JACOB D.
BECK
12-19-25
PROJECT
REVISIONS
54321
D
C
B
A
E
54321 6
/1
/2
:3
:2
A
M
M000
MECHANICAL
SYMBOLS AND
LEGEND
25-027
BID SET 2025-12-19
S L
C C
R M
R
E M
O D
E L
C
O M
M U
N
IT
Y B
L V
D T
A Y
L O
R S
V
IL
L E
U
T
NO. DATE DESCRIPTION
REVIEWED…