This is a Product Specifications document for the Interior Signage for North Regional Courthouse project located at 1600 W Hillsboro Boulevard, Deerfield Beach, Florida 33442, issued by Broward County. The project requires the fabrication, delivery, and installation of interior room identification signage, including permanent room numbers and updateable room functions. The signage must comply with the Florida Building Code, the 2010 ADA Standards for Accessible Design, and all relevant accessibility requirements. Eight sign types are specified with varying dimensions ranging from 8.5 inches in length and 3 inches to 9 inches in height. All signage shall feature a uniform 8-inch width with modular components allowing for inserts, notice holders, occupancy sliders, marker, magnetic, and cork boards, all flush to the sign face. Signs must include Grade II Braille with hemispherical domed dots protruding a minimum of 0.025 inches. The contractor is responsible for installation verification of existing conditions, assessment of the facility, and all sign installation work. Interior walls will be prepared by Broward County, and all work must be performed Monday through Friday from 8:00 a.m. to 5:00 p.m. EST, with building access scheduled and coordinated through the Project Manager in advance.
All signs must meet specific typography and tactile lettering standards established by the ADA Accessibility Guidelines and ICC/ANSI A117.1. Colors are specified as Pewter Grey base (CO102), Satin Silver trim, and White text, with a minimum 70 percent light reflectance value contrast between characters and background. Tactile room numbers must be between 5/8-inch and 3/4-inch high and raised, mounted adjacent to the door latch side with tactile text positioned 48 inches minimum to 60 inches maximum above the finished floor. Mounting shall use high-strength VHB tape or concealed mechanical fasteners depending on wall substrate, with all signs installed level, plumb, and flush to wall surfaces. For Sign Types A and F, vendors must provide polycarbonate or printed paper inserts on templates in Acrobat or Word format to allow owner updates. Prior to fabrication, vendors must submit shop drawings, finish and color samples, and full-size sign mock-ups for each sign type for County review and approval.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTTACHMENT C
Project: North Regional Courthouse Interior Signage
Project Location:
1600 W Hillsboro Blvd.
Deerfield Beach, FL 33442
1. General Scope
This section defines the requirements for the fabrication, delivery, and installation of interior room identification signage, including permanent room numbers and updateable room functions. Signage shall comply with applicable federal, state, and local codes, including the Florida Building Code, the 2010 ADA Standards for Accessible Design, and all relevant accessibility requirements.
2. Sign Requirements
2.1 Dimensions
• Chart with size per type:
Sign type Sign Size
A 8.5”L x 5.75”H
B 8.5”L x 3.5”H
C 8.5”L x 5.75”H
D 8.5”L x 9”H
E 8.5”L x 9”H
F 8.5”L x 3”H
G 8.5”L x 9”H
H 8.5”L x 9”H
• Custom sizes may be used only where required by room name length or architectural constraints. Any deviation from sign specifications must be approved by the Facility Management Project Manager in advance of fabrication.
2.2 Construction
• The signage shall, with the exception of directories and directionals, be a uniform 8
½” width to facilitate inserts printed on standard width paper.
• Insert components shall have a .080 thickness non-glare acrylic window and shall be inlaid flush to sign face for a smooth, seamless appearance.
• The signage shall include modules allowing for inserts, notice holders, occupancy sliders, marker, magnetic, and cork boards. All modules shall be flush to sign face for a smooth, seamless appearance.
• The laminates (front and back) shall be pressure laminated and precision machined together to a 90-degree angle. Edges shall be smooth, void of chips, burrs, sharp edges and marks.
• The signage shall utilize an acrylic sphere for Grade II Braille inserted directly into a scratch resistant, high pressure laminate sign face. Braille dots are to be pressure fit in high tolerance drilled holes.
• Braille dots shall be half hemispherical domed and protruding a minimum 0.025”.
• The signage shall utilize a pressure activated adhesive. The adhesive shall be nonhazardous and shall allow for flexing and deflection of the adhered components due to changes in temperature and moisture without bond failure.
• All signs shall be provided with appropriate mounting hardware. Hardware shall be finished and architectural in appearance and suitable for the mounting surface.
• Some signs may be installed on glass. A blank backer is required to be placed on the opposite side of the glass to cover tape and adhesive. The backer shall match the sign in size and shape.
2.3 Sign Paper Insert
For sign type A, Sign Type F:
• The signage shall accommodate polycarbonate inserts (for clear), or printed paper inserts by Owner to allow updating as required.
• Manufacturer shall provide a template containing layout, font, color, artwork and trim lines to allow Owner to produce inserts on laser or ink jet printer. The template shall be in an Acrobat or Word format (.pdf).
• Insert area measures 4 inches wide x 1.25 inches high.
• Insert area must be protected from dust, moisture, and tampering.
• Vendor to provide digital file template in Word format for paper insert.
3. Typography and Tactile Lettering
• Signs and their installation shall comply with the applicable provisions of the latest edition of the following standards and with requirements of authorities having jurisdiction:
• ADAAG – Americans with Disabilities Act Accessibility Guidelines; US Architectural and Transportation Barriers Compliance Board.
• International Code Council/American National Standards Institute A117.1-Standard on Accessible and Usable Buildings Facilities.
• National Fire Protection Association 101 Life Safety Code.
• Tactile Room Numbers: Minimum 5/8-inch high, Maximum 3/4-inch high, raised
4. Color and Contrast
• All signs must provide a minimum 70% light reflectance value (LRV) contrast between characters and background.
• All components (including inserts) shall maintain compliance with ADA visibility requirements under standard courthouse lighting.
• Surface finish shall be matte or low-glare to minimize reflections.
• Finishes:
o Base: Pewter Grey, CO102 o TRIM: Satin Silver o TEXT: White
5. Mounting and Installation
• All signage is to be installed by contractor.
5.1 Placement
• Signs must be mounted adjacent to the latch side of the door, with tactile text located:
o 48 inches minimum above the finished floor to the baseline of the lowest tactile line o 60 inches maximum to the highest tactile line
5.2 Mounting Method
• Use high-strength VHB tape or concealed mechanical fasteners depending on wall substrate.
• All signs must be level, plumb, and installed flush to wall surfaces.
1. Submittals and Approvals
The vendor is to provide the follow for review and approval by the County prior to fabrication.
o shop drawings, o finish and color samples, o full-size sign mock-up for each sign type.