This is a Limited Asbestos Survey Report prepared by R & R Environmental, Inc. for the Utah State Developmental Center's Raintree Building located in American Fork, Utah, in coordination with the State of Utah Department of Administrative Services, Division of Facilities Construction and Management (DFCM). The survey was conducted in August 2025 to assess asbestos-containing materials (ACM) in the building prior to a planned renovation and mechanical upgrade project. The inspection was performed by Tyler Coles, a Utah Accredited Asbestos Building Inspector (ASB-8562), and reviewed by David C. Roskelley, a certified industrial hygienist and safety professional. Seventy-six bulk samples were collected from suspect materials throughout the building and analyzed via Polarized Light Microscopy (PLM) by Eurofins Reservoirs Environmental, Inc., an NVLAP-accredited laboratory (Lab Code 101896). The survey identified asbestos-containing materials in two primary locations: AHU/Duct Gasket Sealant (approximately 40 square feet containing up to 5% chrysotile asbestos) and TSI-End Sealant (approximately 100 square feet containing up to 8% chrysotile asbestos).
The identified asbestos-containing materials must be removed prior to disturbance by a licensed abatement contractor before the planned $2,100,000 mechanical and plumbing upgrade to the Raintree Building proceeds. The survey report acknowledges inherent limitations in asbestos identification procedures and emphasizes that while the investigation reduces uncertainty, it does not guarantee identification of all ACM present in the structure. Materials are classified as either NESHAP-regulated asbestos-containing materials (R-ACM) or non-regulated asbestos-containing materials (N-R-ACM) based on their friability and potential for disturbance during renovation activities. The report includes detailed appendices with sample logs, laboratory results, photographic documentation, and floor plans to support the findings and recommendations for safe handling during the upcoming construction project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS (LIMITED), LEAD (LIMITED), AND HAZARDOUS MATERIALS
INSPECTION, SURVEY AND ASSESSMENT
FOR THE
UTAH STATE DEVELOPMENTAL CENTER
RAINTREE BUILDING
1088 NORTH 870 EAST
AMERICAN FORK, UTAH 84003
A LIMITED ASBESTOS SURVEY AND ASSESSMENT
FOR THE
UTAH STATE DEVELOPMENTAL CENTER
RAINTREE BUILDING
October 14, 2025
Prepared for:
Mrs. Aubrey Stapel
Project Manager
State of Utah
Department of Administrative Services
Division of Facilities Construction and Management (DFCM)
State Office Building Room 4110
Salt Lake City, Utah 84114
PH: (801) 641-0964
Prepared by:
R & R Environmental, Inc. (R & R)
47 West 9000 South, Suite #2
Sandy, Utah 84070 dave@rrenviro.com
Phone (801) 541-1035
TABLE OF CONTENTS
ASBESTOS
1.0 INTRODUCTION
2.0 EXECUTIVE SUMMARY
3.0 SAMPLING METHODS
4.0 SURVEY RESULTS
5.0 CONCLUSIONS
6.0 LIMITATIONS AND EXCLUSION OF WARRANTY.……………………………………………………6
List of Appendices
Appendix A Sample Log
Appendix B Laboratory Report
Appendix C Photo Log
Appendix D Floor Plans
Appendix E State of Utah Certifications
Limited Asbestos Survey Report Page 1 USDC, Raintree Building American Fork, Utah 84003
1.0 INTRODUCTION
R & R Environmental, Inc. (R & R) was contacted to conduct a limited asbestos survey for the
Utah State Developmental Center, Raintree Building located at 1088 North 870 East in American
Fork, Utah 84003. The Raintree Building is scheduled to undergo a renovation. The survey consisted of a visual assessment of the structure for suspect asbestos containing materials (ACM) and bulk sampling of the materials. The fieldwork component of this survey was conducted by
Mr. Tyler Coles who is a Utah Accredited Asbestos Building Inspector.
This report presents the conditions and observations noted on the visit dates.
The following general information is included in this survey report:
• Executive Summary (Section 2.0)
• Sampling Methods (Section 3.0)
• Analytical Results (Section 4.0)
• Conclusions (5.0)
Limited Asbestos Survey Report Page 2
2.0 EXECUTIVE SUMMARY
The asbestos-containing material (ACM) identified at the Utah State Developmental
Center, Raintree Building located at 1088 North 870 East in American Fork, Utah 84003 is as follows:
Material Location Quantity % Asbestos Friable Condition Photo
AHU/Duct Gasket
Sealant 130 40 ft2
Up to
5% Chrysotile No Good 2
TSI-End Sealant Throughout ~100 ft2 Up to
8% Chrysotile Yes Good 3/4
Limited Asbestos Survey Report Page 3
UTAH STATE DEVELOPMENTAL CENTER, RAINTREE BUILDING
1088 NORTH 870 EAST, AMERICAN FORK, UTAH 84003
DATE OF SURVEY: AUGUST 2025
NESHAP - REGULATED
ASBESTOS-CONTAINING MATERIALS (R-ACM)
1. Friable asbestos material (>1% asbestos and can be crumbled, pulverized, or reduced to powder by hand pressure)
X Thermal system insulation (TSI)*
Textured ceiling material (TCM)*
Spray-on insulation or fireproofing*
Blown-in insulation*
Ceiling tiles/panels*
Plaster, gypsum board, gypsum board joint compound*
Cloth materials* (Boiler Flue Gasket)
Paper materials* (HVAC Paper Tape and Insulating Board)
Electrical wiring insulation*
Sink undercoating (loose)*
Other*
2. Category I ACM which has become friable
Packings
Gaskets
Resilient floor coverings (floor tile and sheet vinyl)
Asphalt roofing products (Dust Debris, Roofing Underlayment Debris, Flashing Material)
3. Category I ACM that will be or has been subjected to sanding, grinding, cutting, or abrading
Packings
X Gaskets
Resilient floor coverings (floor tile and sheet vinyl)
Asphalt roofing products
4. Category II ACM that has a high probability of becoming or has become friable during demolition or renovation operations
Asbestos cement materials (TransiteT)*
Asphalt, tar and rubber-base ACM products other than roofing products*
Non-asphalt and non-paper roofing products*
Paint*
Fire brick and/or mortar*
Stainless steel sink undercoating (solid)*
Encapsulated TCM*
Encapsulated TSI*
Mastic for floor tile, ceiling tile, cove molding, etc.*
Other
Limited Asbestos Survey Report Page 4
UTAH STATE DEVELOPMENTAL CENTER, RAINTREE BUILDING
1088 NORTH 870 EAST, AMERICAN FORK, UTAH 84003
DATE OF SURVEY:AUGUST 2025
NESHAP NON-REGULATED
ASBESTOS-CONTAINING MATERIAL (N-R-ACM)
1. > 1% asbestos
2. Category I Non-friable (cannot be crumbled, pulverized, or reduced to powder by hand pressure)
ACM with >1% asbestos by new PLM procedure
Packings
X Gaskets (Window Glazing & Caulking)
Resilient floor coverings (floor tile)
X Asphalt roofing products
3. Category II Non-friable ACM with >1% asbestos by new PLM procedure (Category includes items meeting Category I definition but not specifically listed in that category)
Asbestos cement materials (TransiteT)* (Fume hoods, counter tops, and window panels)
Asphalt, tar and rubber-base ACM products other than roofing products*
X Non-asphalt and non-paper roofing products*
Paint* (Silver Paint Sealant)
Fire brick and/or mortar*
Sink undercoating (solid)*
Mastic for floor tile, ceiling tile, cove molding, etc.*
Other* (Fire Rated Door/Frame)
Notes:
1. (*) Denotes R&R’s interpretation of materials included in this category.
2. New PLM procedure is outlined in Appendix A, Subpart F, 40 CFR, Part 783, Section 1, Polarized Light Microscopy.
3. The Environmental Protection Agency (EPA) National Emission Standard for Hazardous Air
Pollutants (NESHAP) asbestos revision as outlined in 40 CFR, Part 61, became effective
November 20, 1990. The asbestos classification system outlined in the revision and included in this section is dynamic in nature. Asbestos materials classified as “NON-REGULATED” at the time of the survey may become “REGULATED” due to ongoing or planned maintenance, renovation, or demolition actions, which can transform a material containing greater than 1% asbestos from a “non-friable” and NON-REGULATED to a friable and REGULATED condition.
Classification of ACM in this section and in the executive summary of this report is, therefore, based on the observations of the surveyor at the time of the survey and may or may not be appropriate at later dates.
4. Maintenance, renovation, demolition, weathering, normal wear, water, or other damage can alter the “NON-REGULATED” status of materials, and necessitate precautions required for handling them as “REGULATED” asbestos-materials.
Limited Asbestos Survey Report Page 5
3.0 SAMPLING METHODS
Survey procedures were based on those outlined in Title 40 Code of Federal Regulation (CFR)
Part 763, USEPA Asbestos Hazard Emergency Response Act, and the Asbestos Model
Accreditation Plan (effective April 4, 1994). The procedures included visual observation, physical inspection, bulk sample collection, and condition assessment of suspect ACM. The number of samples collected was based on the amount and accessibility of each homogeneous material, with consideration given for the type, age, and condition.
Seventy-six (76) samples were collected from the suspect materials to assess the presence of asbestos (or lack thereof) in building materials/systems. Each sample collected was placed into a sealable plastic bag or tub, marked with a unique sample identification code, and packaged for subsequent shipment to the laboratory for analysis. Individual sample identification consisted of a numeric code denoting the sampling media/location.
After packaging and labeling, samples were submitted under proper chain-of-custody to
Reservoirs Environmental, Inc., Denver, Colorado. The National Voluntary Laboratory
Accreditation Program (NVLAP), Lab Code 101896 accredits Reservoirs for asbestos analysis.
Samples were analyzed via Polarized Light Microscopy (PLM) utilizing EPA Method 600/M4-
82-020. Please note that USEPA and OSHA regulations define an ACM as a material containing more than one (1) percent asbestos, by volume, as determined by PLM analysis. In the case of multi-layer systems (e.g., floor tile/mastic layers), the laboratory analyzed and reported each layer separately.
4.0 SURVEY RESULTS
Seventy-six (76) representative samples collected were submitted for analytical determination. A summary of analytical results for samples collected and analyzed for this survey are in Appendix
B (Laboratory Results) and are discussed below by building material/system type. Photographs of the buildings where samples were taken are included as Appendix C. Floor Plans of the building where samples were taken are included in Appendix D
Limited Asbestos Survey Report Page 6
5.0 CONCLUSIONS
Asbestos-containing materials were identified in the building. See Executive Summary for details
The identified materials must be removed prior to disturbance by a licensed abatement contractor.
6.0 LIMITATIONS AND EXCLUSION OF WARRANTY
This limited asbestos survey and assessment was performed using procedures and a level of diligence typically exercised by professional consultants performing similar services.
However, asbestos-containing material (ACM) can be present in a structure, but not identified using ordinary investigative procedures.
No asbestos survey can completely, eliminate uncertainty regarding the presence of ACM.
R&R Environmental, Inc.’s level of diligence and investigative procedures are intended to reduce, but not eliminate, potential uncertainty regarding the presence of ACM. The procedures used for this survey attempt to establish a balance between the competing goals of limiting investigative costs, time, and building damage, and reducing the uncertainty about unknown conditions. Therefore, the determinations in this report should not be construed as a guarantee that all ACM present in the subject property has been included in this report.
This report presents R&R Environmental, Inc.’s professional determinations, which are dependent upon information obtained during performance of consulting services. R&R
Environmental, Inc. assumes no responsibility for omissions or errors resulting from inaccurate information provided by sources outside of R&R Environmental, Inc.
No warranty or guarantee, expressed or implied, is made regarding the findings, conclusions, or recommendations contained in this report. The limitations presented above supersede the requirements or provisions of all other contracts or scopes of work, implied, or otherwise, except stated or acknowledged herein.
Limited Asbestos Survey Report Page 7
A LIMITED ASBESTOS SURVEY AND ASSESSMENT
OF THE
UTAH STATE DEVELOPMENTAL CENTER
RAINTREE BUILDING
During the month of August 2025, R & R Environmental, Inc. (R & R) of Sandy, Utah, conducted a limited asbestos survey and assessment of the Utah State Developmental Center, Raintree
Building located at 1088 North 870 East in American Fork, Utah 84003. Bulk samples of suspect asbestos-containing materials were collected and analyzed. The condition of all friable and non-friable asbestos-containing materials was, assessed. The following accredited inspector conducted the survey and assessment.
Inspected by:
Tyler Coles Date
State of Utah, Division of Air Quality Inspector
Certification Number: ASB-8562
State of Utah Company Certification: ASBC-237
This report was reviewed by:
David C. Roskelley, MSPH, CIH, CSP Date
State of Utah, Division of Air Quality Inspector
Certification Number: ASB-1370
AHERA Inspector #5 PSI 65451 I
Certified Safety Professional #15774
Certified Industrial Hygienist #8529
State of Utah Company Certification: ASBC-237
Appendix A
Sample Log
SAMPLE LOG
AUGUST 2025
Sample #
Material/
Homogenous Area Sample Location Quantity
Lab Result
(%/Type) Assessment
RT-01 Wall Insulation System 130 700 ft2 None Detected Undamaged
RT-02 Wall Insulation System 130 700 ft2 None Detected Undamaged
RT-03 Wall Insulation System 130 700 ft2 None Detected Undamaged
RT-04 TSI-End Sealant 130 40 ft2 None Detected Partial Damage
RT-05 TSI-End Sealant 130 40 ft2 None Detected Partial Damage
RT-06 TSI-End Sealant 130 40 ft2 None Detected Partial Damage
RT-07 TSI-Jacket 130 600 LF None Detected Partial Damage
RT-08 TSI-Jacket 130 600 LF None Detected Partial Damage
RT-09 TSI-Jacket 130 600 LF None Detected Undamaged
RT-10 Wall Packing (Red) Electrical 6 ft2 None Detected Undamaged
RT-11 Wall Packing (Red) Electrical 6 ft2 None Detected Undamaged
RT-12 Vibration Isolator 130 8 ft2 None Detected Undamaged
RT-13 Vibration Isolator 130 8 ft2 None Detected Undamaged
RT-14 AHU/Duct Gasket Sealant 130 40 ft2 4% Chrysotile Undamaged
RT-15 AHU/Duct Gasket Sealant 130 40 ft2 4% Chrysotile Undamaged
RT-16 Pipe Thread Sealant 130 30 ft2 None Detected Undamaged
RT-17 Pipe Thread Sealant 130 30 ft2 None Detected Undamaged
RT-18 Duct Sealant (Gray) 130 50 ft2 None Detected Undamaged
RT-19 Duct Sealant (Gray) 130 50 ft2 None Detected Undamaged
RT-20 TSI-End Sealant 126 100 ft2 None Detected Undamaged
RT-21 TSI-End Sealant 126 100 ft2 None Detected Undamaged
RT-22 TSI-End Sealant 126 100 ft2 None Detected Undamaged
Homogenous Area Sample Location Quantity
Lab Result
(%/Type) Assessment
RT-23 TSI-Tank Wrapping 126 30 LF None Detected Undamaged
RT-24 TSI-Tank Wrapping 126 30 LF None Detected Undamaged
RT-25 TSI-Tank Wrapping 126 30 LF None Detected Undamaged
RT-26 TSI-Jacket (Brace) 126 Tunnel 180 LF None Detected Undamaged
RT-27 TSI-Jacket (Brace) 126 Tunnel 180 LF None Detected Undamaged
RT-28 TSI-Jacket (Brace) 126 Tunnel 180 LF None Detected Undamaged
RT-29 TSI-End Sealant 126 60 ft2 8% Chrysotile Undamaged
RT-30 TSI-End Sealant 126 60 ft2 None Detected Undamaged
RT-31 TSI-End Sealant 126 60 ft2 8% Chrysotile Undamaged
RT-32 Sink Undercoat (Grey) Apartment 4 Kitchen >350 ft2 None Detected Undamaged
RT-33 Sink Undercoat (Grey) Apartment 4 Kitchen >350 ft2 None Detected Undamaged
RT-34 Roof Shingles Roof 2,000 ft2 None Detected Undamaged
RT-35 Roof Shingles Roof 2,000 ft2 None Detected Undamaged
RT-36 Roof Shingles Roof 2,000 ft2 None Detected Undamaged
RT-37 Roof Shingles Roof 2,000 ft2 None Detected Undamaged
WCRT-01 Black Fitting Generator 5 ft2 None Detected Undamaged
WCRT-02 Red Fitting Generator 5 ft2 None Detected Undamaged
WCRT-03 Door Insulation Generator 20 ft2 None Detected Undamaged
WCRT-04 Door Insulation Generator 20 ft2 None Detected Undamaged
WCRT-05 Door Insulation Generator 20 ft2 None Detected Undamaged
WCRT-06 Pipe Thread Sealant Generator 2 ft2 None Detected Undamaged
WCRT-07 Black Fitting Generator 5 ft2 None Detected Undamaged
WCRT-08 Black Fitting Generator 5 ft2 None Detected Undamaged
WCRT-09 Red Fitting Generator 5 ft2 None Detected Undamaged
WCRT-10 Red Fitting Generator 5 ft2 None Detected Undamaged
MAY 23, 2023
Homogenous Area Sample Location Quantity
Lab Result
(%/Type) Assessment
USDCRT-03 Wall System East Entry 4,662 ft2 None Detected Undamaged
USDCRT-04 Wall System Multipurpose 4,662 ft2 None Detected Undamaged
USDCRT-05 Wall System North Storage 4,662 ft2 None Detected Undamaged
RAIN-06 Wall System Boiler Room 4,662 ft2 None Detected Undamaged
RAIN-07 Wall System 425 4,662 ft2 None Detected Undamaged
RAIN-08 2’ x 2’ Ceiling Panel Nurse Station 650 ft2 None Detected Undamaged
RAIN-09 12” Ceiling Tile Conference Room 1,785 ft2 None Detected Undamaged
RAIN-10 12” Ceiling Tile Outside Break
Room 1,785 ft2 None Detected Undamaged
RAIN-11 2’ x 2’ Ceiling Panel Apartment 3 Kitchen 650 ft2 None Detected Undamaged
USDCRT-11 CMU Block Filler Conference Room 8,120 ft2 None Detected Undamaged
USDCRT-12 CMU Block Filler Conference Room 8,120 ft2 None Detected Undamaged
USDCRT-13 CMU Block Filler Boiler Room 8,120 ft2 None Detected Undamaged
USDCRT-14 CMU Block Filler Boiler Room 8,120 ft2 None Detected Undamaged
USDCRT-15 CMU Block Filler West Entry 8,120 ft2 None Detected Undamaged
USDCRT-16 CMU Block Filler East Storage 8,120 ft2 None Detected Undamaged
RAIN-13 CMU Block Filler Apartment 5
Bedroom 8,120 ft2 None Detected Undamaged
OCTOBER 29, 2012
Homogenous Area Sample Location Quantity
Lab Result
(%/Type) Assessment
Rain – 01 Cream Flooring with
Aggregate Pattern Supply Room ~4,000 ft2 None Detected Undamaged
Rain – 02 Cream Flooring with
Aggregate Pattern Towel Closet ~4,000 ft2 None Detected Undamaged
Rain – 03 Cream Flooring with
Aggregate Pattern Main Laundry ~4,000 ft2 None Detected Undamaged
Rain – 04
Sheet Vinyl Flooring
(Gray with Blue and Pink
Specks) & Mastic
Nurse Station 650 ft2 None Detected Undamaged
Rain – 05 Vinyl Cove Base
(Cream Colored) & Mastic Copy Room 650 ft2 None Detected Undamaged
Rain – 06 Wall System Boiler Room 2,500 ft2 None Detected Undamaged
Rain – 07 Wall System 425 2,500 ft2 None Detected Undamaged
Rain – 08 2’ x 2’ Ceiling Panel
(Gray Sand texture) Nurse Station 2,500 ft2 None Detected Undamaged
Rain – 09 12” Ceiling Tile (White with Fissures and Holes) Hall Outside 650 ft2 None Detected Undamaged
Rain – 10 12” Ceiling Tile (White with Fissures and Holes)
Conference Room, Outside Break Room >1,500 ft2 None Detected Undamaged
Rain – 11 2’ x 2’ Ceiling Panel
(Drywall) Apartment 3 Kitchen >1,500 ft2 None Detected Undamaged
Rain – 12 Sink Undercoat (Gray) Apartment 4 Kitchen >350 ft2 None Detected Undamaged
Rain – 13 CMU Block Filler Apartment 5
Bedroom >1,000 ft2 None Detected Undamaged
Rain – 14 TSI-End Sealant Boiler Room 60 ft2 None Detected Undamaged
Rain – 15 TSI-End Sealant Tunnels 60 ft2 6% Chrysotile Undamaged
Rain – 16 TSI-End Sealant Central HVAC 40 ft2 None Detected Undamaged
Homogenous Area Sample Location Quantity
Lab Result
(%/Type) Assessment
Rain - 17 AC Duct Sealant Central HVAC Room 150 ft2 None Detected Undamaged
Rain – 18 AC Unit Sealant Central HVAC
Room 40 ft2 5% Chrysotile Undamaged
Rain – 19 Vibration Isolator Central HVAC Room 60 ft2 None Detected Undamaged
Rain – 20 Wall Insulation System Central HVAC Room 400 ft2 None Detected Undamaged
Rain – 21 Window Sealant Exterior Windows 150 ft2 None Detected Undamaged
Rain – 22 Window Sealant Roof s 150 ft2 None Detected Undamaged
Rain – 23 Roof Shingles Angled Roof
Surfaces 2,000 ft2 None Detected Undamaged
Appendix B
Laboratory Report
August 20, 2025
Sincerely, Jeanne Spencer President
Subcontractor Number:
Laboratory Report: RES 683727-1
Project #/P.O. #: USDC
Project Description: Raintree Bulk 8/19
Ty Coles R & R Environmental 47 West 9000 South #2 Sandy, UT 84070
Dear Ty, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
RES 683727-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
by Camryn Baumgartner
08/20/202508/20/202508/20/202508/20/2025
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
4955 Yarrow St, Suite 100, Arvada, CO 80002
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non- AAAA SubSubSubSub AsbestosAsbestosAsbestosAsbestos FibrousFibrousFibrousFibrous YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 683727 -683727 -683727 -683727 - RT-01RT-01RT-01RT-01 A Brown insulation 100 NDNDNDND 90 10.0 683727 -683727 -683727 -683727 - RT-02RT-02RT-02RT-02 A Brown insulation 100 NDNDNDND 90 10.0 683727 -683727 -683727 -683727 - RT-03RT-03RT-03RT-03 A Brown insulation 100 NDNDNDND 90 10.0 683727 -683727 -683727 -683727 - RT-04RT-04RT-04RT-04 A Yellow insulation w/ white/silver wrap 40 NDNDNDND 80 20.0 B White sealant 60 NDNDNDND 0 100.0 683727 -683727 -683727 -683727 - RT-05RT-05RT-05RT-05 A Yellow insulation 30 NDNDNDND 90 10.0 B White sealant 70 NDNDNDND 0 100.0 683727 -683727 -683727 -683727 - RT-06RT-06RT-06RT-06 A Yellow insulation w/ white/silver wrap 40 NDNDNDND 80 20.0 B White sealant 60 NDNDNDND 0 100.0 683727 -683727 -683727 -683727 - RT-07RT-07RT-07RT-07 A Yellow insulation w/ white/silver wrap & white paint 100 NDNDNDND 80 20.0 683727 -683727 -683727 -683727 - RT-08RT-08RT-08RT-08 A White sealant 50 NDNDNDND 0 100.0 B White/silver wrap 50 NDNDNDND 65 35.0 683727 -683727 -683727 -683727 - RT-09RT-09RT-09RT-09 A Yellow insulation w/ white/silver wrap 50 NDNDNDND 75 25.0 B White sealant 50 NDNDNDND 0 100.0 683727 -683727 -683727 -683727 - RT-10RT-10RT-10RT-10 A Red fireproofing 100 NDNDNDND 15 85.0 683727 -683727 -683727 -683727 - RT-11RT-11RT-11RT-11 A Red fireproofing 100 NDNDNDND 15 85.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 683727-1
R & R Environmental
USDC
Raintree Bulk 8/19 August 20, 2025 EPA 600/R-93/116 - Short Report, Bulk Priority August 20, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 683727 -683727 -683727 -683727 - RT-12RT-12RT-12RT-12 A Black fibrous resinous material 100 NDNDNDND 30 70.0 683727 -683727 -683727 -683727 - RT-13RT-13RT-13RT-13 A Black fibrous resinous material 100 NDNDNDND 30 70.0 683727 -683727 -683727 -683727 - RT-14RT-14RT-14RT-14 A Light-gray resinous material 100 ChrysotileChrysotileChrysotileChrysotile 4444 0 96.0 683727 -683727 -683727 -683727 - RT-15RT-15RT-15RT-15 A Light-gray resinous material 100 ChrysotileChrysotileChrysotileChrysotile 4444 0 96.0 683727 -683727 -683727 -683727 - RT-16RT-16RT-16RT-16 A Gray/white resinous material 100 NDNDNDND 0 100.0 683727 -683727 -683727 -683727 - RT-17RT-17RT-17RT-17 A Brown resinous material 100 NDNDNDND 0 100.0 683727 -683727 -683727 -683727 - RT-18RT-18RT-18RT-18 A Gray resinous material 100 NDNDNDND 0 100.0 683727 -683727 -683727 -683727 - RT-19RT-19RT-19RT-19 A Gray resinous material 100 NDNDNDND 0 100.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Josh Baker Analyst
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 683727-1
R & R Environmental
USDC
Raintree Bulk 8/19 August 20, 2025 EPA 600/R-93/116 - Short Report, Bulk Priority August 20, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
SUBMITTED BY INVOICE TO
Client Sample ID Number
RES Job #: 683727
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Company: R & R Environmental Company: R & R Environmental
Address: 47 West 9000 South #2 Address: 47 West 9000 South #2
Sandy, UT 84070 Sandy, UT 84070
Project Number and/or P.O. #: USDC Project Zip Code:
Project Description/Location: Raintree Bulk 8/19
Contact: Ty Coles -1 PLM Priority Phone: (801) 830-1924
Fax:
Cell: (801) 830-1924
Final Data Deliverable Email Address:
ty@rrenviro.com (+ 2 ADDNL. CONTACTS)
PLM / PCM / TEM DTL RUSH PRIORITY STANDARD Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
Mold Analysis RUSH PRIORITY STANDARD
Special Instructions:
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
1 RT-01 X B
2 RT-02 X B
3 RT-03 X B
4 RT-04 X B
5 RT-05 X B
6 RT-06 X B
7 RT-07 X B
8 RT-08 X B
9 RT-09 X B
10 RT-10 X B
11 RT-11 X B
12 RT-12 X B
13 RT-13 X B
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET 30 days. Failure to comply with payment terms may result in a 1.5% monthly interest surcharge.
Relinquished By:
Ty Coles Date/Time: 08/19/2025 14:50:42 Sample Condition: Acceptable
Received By:
Emily Creasey Date/Time: 08/20/2025 10:34:07 Carrier: Fed-Ex
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
Laboratory Analysis Instructions
(Sample ID's must be unique)
Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Surface = SU Swab = SW
Tape = T Wipe = W
Drinking Water = DW
Waste Water = WW
**ASTM E1792 approved wipe media only**
RES Job #: 683727
Submitted By: R & R Environmental
14 RT-14 X B
15 RT-15 X B
16 RT-16 X B
17 RT-17 X B
18 RT-18 X B
19 RT-19 X B
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
August 28, 2025
Jeanne Spencer President
Subcontractor Number:
Laboratory Report: RES 685917-1
Project #/P.O. #: USDC
Project Description: Raintree Bulk 2
Ty Coles R & R Environmental 47 West 9000 South #2 Sandy, UT 84070
Dear Ty, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
RES 685917-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
by Camryn Baumgartner
08/28/202508/28/202508/28/202508/28/2025
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 685917 -685917 -685917 -685917 - RT-20RT-20RT-20RT-20 A White sealant 10 NDNDNDND 5 95.0 B Brown insulation w/ off-white/silver wrap 90 NDNDNDND 85 15.0 685917 -685917 -685917 -685917 - RT-21RT-21RT-21RT-21 A White sealant 35 NDNDNDND 5 95.0 B Brown insulation w/ off-white/silver wrap 65 NDNDNDND 85 15.0 685917 -685917 -685917 -685917 - RT-22RT-22RT-22RT-22 A White sealant 30 NDNDNDND 5 95.0 B Brown insulation w/ off-white/silver wrap 70 NDNDNDND 85 15.0 685917 -685917 -685917 -685917 - RT-23RT-23RT-23RT-23 A Yellow insulation w/ off-white/silver wrap 100 NDNDNDND 85 15.0 685917 -685917 -685917 -685917 - RT-24RT-24RT-24RT-24 A Yellow insulation w/ off-white/silver wrap 100 NDNDNDND 85 15.0 685917 -685917 -685917 -685917 - RT-25RT-25RT-25RT-25 A Yellow insulation w/ off-white/silver wrap 100 NDNDNDND 90 10.0 685917 -685917 -685917 -685917 - RT-26RT-26RT-26RT-26 A Off-white/silver wrap 5 NDNDNDND 65 35.0 B Off-white insulation 95 NDNDNDND 15 85.0 685917 -685917 -685917 -685917 - RT-27RT-27RT-27RT-27 A Off-white/silver wrap 4 NDNDNDND 65 35.0 B Off-white insulation 96 NDNDNDND 15 85.0 685917 -685917 -685917 -685917 - RT-28RT-28RT-28RT-28 A Off-white insulation 100 NDNDNDND 15 85.0 685917 -685917 -685917 -685917 - RT-29RT-29RT-29RT-29 A White sealant 20 ChrysotileChrysotileChrysotileChrysotile 8888 0 92.0 B Yellow insulation 80 NDNDNDND 95 5.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 685917-1
R & R Environmental
USDC
Raintree Bulk 2 August 28, 2025 EPA 600/R-93/116 - Short Report, Bulk Priority August 28, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 685917 -685917 -685917 -685917 - RT-30RT-30RT-30RT-30 A Yellow insulation 35 NDNDNDND 95 5.0 B White sealant 65 NDNDNDND 0 100.0 685917 -685917 -685917 -685917 - RT-31RT-31RT-31RT-31 A Beige sealant 15 ChrysotileChrysotileChrysotileChrysotile 8888 0 92.0 B Tan insulation 85 NDNDNDND 95 5.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Andrew Roberts Analyst
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 685917-1
R & R Environmental
USDC
Raintree Bulk 2 August 28, 2025 EPA 600/R-93/116 - Short Report, Bulk Priority August 28, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
RES Job #: 685917
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Project Description/Location: Raintree Bulk 2
Contact: Ty Coles -1 PLM Priority Phone: (801) 830-1924
Fax:
Cell: (801) 830-1924
Final Data Deliverable Email Address:
ty@rrenviro.com (+ 2 ADDNL. CONTACTS)
PLM / PCM / TEM DTL RUSH PRIORITY STANDARD Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
1 RT-20 X B
2 RT-21 X B
3 RT-22 X B
4 RT-23 X B
5 RT-24 X B
6 RT-25 X B
7 RT-26 X B
8 RT-27 X B
9 RT-28 X B
10 RT-29 X B
11 RT-30 X B
12 RT-31 X B
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET 30 days. Failure to comply with payment terms may result in a 1.5% monthly interest surcharge.
Ty Coles Date/Time: 08/27/2025 15:37:50 Sample Condition: Acceptable
Emily Creasey Date/Time: 08/28/2025 11:08:03 Carrier: Fed-Ex
Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
September 14, 2025
Jeanne Spencer President
Subcontractor Number:
Laboratory Report: RES 689678-1
Project #/P.O. #: USDC
Project Description: Willowcreek/Raintree Generator 9/11/25
Ty Coles R & R Environmental 47 West 9000 South #2 Sandy, UT 84070
Dear Ty, Eurofins Reservoirs is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA LAP), Lab ID 101533 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively.
Eurofins Reservoirs has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office.
RES 689678-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Eurofins Reservoirs will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed, as received and with the information provided by the customer. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Eurofins Reservoirs. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986.
by Camryn Baumgartner
09/14/202509/14/202509/14/202509/14/2025
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Laboratory Sample IDLaboratory Sample IDLaboratory Sample IDLaboratory Sample ID LLLL Asbestos ContentAsbestos ContentAsbestos ContentAsbestos Content Non-Non-Non-Non- Non-Non-Non-Non-
YYYY PhysicalPhysicalPhysicalPhysical PartPartPartPart MineralMineralMineralMineral VisualVisualVisualVisual FibrousFibrousFibrousFibrous ComponentsComponentsComponentsComponents EEEE DescriptionDescriptionDescriptionDescription EstimateEstimateEstimateEstimate ComponentsComponentsComponentsComponents
Client Sample NumberClient Sample NumberClient Sample NumberClient Sample Number RRRR (%) (%) (%) (%) 689678 -689678 -689678 -689678 - WCRT-01WCRT-01WCRT-01WCRT-01 A Black resinous material 100 NDNDNDND 0 100.0 689678 -689678 -689678 -689678 - WCRT-02WCRT-02WCRT-02WCRT-02 A Reddish-brown resinous material w/ white fibrous woven material
100 NDNDNDND 25 75.0
689678 -689678 -689678 -689678 - WCRT-03WCRT-03WCRT-03WCRT-03 A Black resinous material w/ gray foam 100 NDNDNDND TR 100.0 689678 -689678 -689678 -689678 - WCRT-04WCRT-04WCRT-04WCRT-04 A Green foam w/ black resinous material 100 NDNDNDND 0 100.0 689678 -689678 -689678 -689678 - WCRT-05WCRT-05WCRT-05WCRT-05 A Black resinous material w/ dark-gray foam 30 NDNDNDND TR 100.0 B Green foam w/ black resinous material 70 NDNDNDND 0 100.0 689678 -689678 -689678 -689678 - WCRT-06WCRT-06WCRT-06WCRT-06 A Brown resinous material 100 NDNDNDND 0 100.0 TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Brett Colbert Analyst
Eurofins Reservoirs Environmental, Inc Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
RES Job Number:
Client:
Client Project/P.O.:
Client Project Description:
Date Samples Received:
Analysis Type:
Turnaround:
Date Samples Analyzed:
RES 689678-1
R & R Environmental
USDC
Willowcreek/Raintree Generator 9/11/25 September 12, 2025 EPA 600/R-93/116 - Short Report, Bulk Priority September 14, 2025
EUROFINS RESERVOIRS ENVIRONMENTAL, INC
NVLAP Lab Code 101896-0
AIHA LAP, LLC. LAB ID 101533
TABLE: I ANALYSIS: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
NA = Not Analyzed NR = Not Received ND = None Detected TR = Trace; <1 % Visual Estimate Trem-Act = Tremolite-Actinolite
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
RES Job #: 689678
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Project Description/Location: Willowcreek/Raintree Generator 9/11/25
Contact: Ty Coles -1 PLM Priority Phone: (801) 830-1924
Fax:
Cell: (801) 830-1924
Final Data Deliverable Email Address:
ty@rrenviro.com (+ 2 ADDNL. CONTACTS)
PLM / PCM / TEM DTL RUSH PRIORITY STANDARD Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
1 WCRT-01 X B
2 WCRT-02 X B
3 WCRT-03 X B
4 WCRT-04 X B
5 WCRT-05 X B
6 WCRT-06 X B
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Reservoirs Environmental, Inc establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Reservoirs Environmental, Inc will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET30. Failure to comply with payment terms may result in a 18% APR finance charge.
Ty Coles Date/Time: 09/12/2025 10:39:16 Sample Condition: Acceptable
Emily Creasey Date/Time: 09/12/2025 11:49:33 Carrier: Fed-Ex
Eurofins Reservoirs QA Manual
Effective September 06, 2023 Q:\QAQC\Eurofins Reservoirs QA Manual.pdf
(303) 964-1986
(866) RES-IENV
https://www.eurofinsus.com/builtenv https://clients.rei.et.eurofinsus.com
Appendix C
Photo Log
PHOTO 1: Utah State Developmental Center, Raintree Building
PHOTO 2: Asbetsos Containing AHU/Duct
Gasket Sealant
PHOTO 3: Asbetsos Containing TSI-End
Sealant
PHOTO 4: Asbetsos Containing TSI - End
Sealant
R & R Environmental, Inc.
47 West 9000 South, Suite #2, Sandy, Utah 84070
(801) 352-2380 • Fax: (801) 352-2381
SITE PHOTOGRAPHS
ALIMITED ASBESTOS SURVEY AND
ASSESSMENT
USDC
RAINTREE BUILDING
PROJECT NO:
DESIGNED BY:
SCALE:
REVIEWED BY:
DRAWN BY:
DATE:
FILE:
Appendix D
Floor Plan
Appendix E
State of Utah Certifications
Utah Asbestos Certification Department of
Environmental Quality Tim Davis lnltrlm Extcurivt Dlrtcror
Tyler Coles
- " 0 ~
State of Utah
SPENCERJ.COX
Gm-,-
OEIDRE HENDERSON
lktltffltml Gcn't!mor
DIVISION OF AIR QUALITY
Bryce C. Bird
Dirtctor
\ _/ zX;;...-1::!
April l , 2025
Tyler Coles R&R Environmental, Inc.
47 West 9000 South, #2 Sandy,UT 84070
Dear Mr. Coles:
Re: Utah Asbestos Program Individual Certification Card
DAQA-001-25
The Utah Division of Air Quality (DAQ) has reviewed your Utah Asbestos Program Certification Application for Individuals and we.are pleased to inform you that your application has been approved.
Your new asbestos program individual certification card is enclosed with this letter and this card is the sole method of individual certification documentation that you will receive from the DAQ.
Please check the information on your asbestos program certification card carefully. Please confirm th.at the photograph, name, and certification discipline(s) are correct. Also, please remember to keep your current asbestos program certification card with you at all times when you are performing regulated asbestos work activities.
Please contact Barbara Perkins at (80 I) 536-0221 or at bperkins@utah.gov if you have any questions regarding this letter or the enclosed asbestos program certification card.
Sincerely, ~y~ Leonard Wright v,i.r n.io:18 MOT)
Leonard Wright, Manager Air Toxics, Lead-Based Paint, and Asbestos Section
LW:BP:lr
195 North 1950 West, 4"' Floor• Salt Lake City, UT Maili111 Addrca: P.O. Box 144820 • Salt Lake City, UT 84114-4820
Ttlcphonc (80 I) 536-4000 • Fu (801) 536-4099 • T.D.D. (801) 536-4414 www."'19.11tah.1l"V
Prinlcd OC1 IO<We ro<:yti.d pepor
Utah Lead-Based Paint Certification
State of Utah
SPENCER J. COX
Go,·tmor
DEIDRE HENDERSON
litutenant Gol'limor
February 11, 2025
Steve Smith
Department of Environmental Quality
Kimberly D. Shelley Exec11tfre Director
DIVISION OF AIR QUALITY
Bryce C Bird
Director
R&R Environmental, Inc.
4 7 West 9000 South, #2 Sandy, UT 84070
Dear Mr. Smith:
Re: Utah Lead-Based Paint Program Individual Certification Card
Inspector l Risk Aue
-4~;_·~
Director, Utah D1v1sion of Air Quality
DAQA-002-25
The Utah Division of Air Quality (DAQ) has reviewed your Utah Lead-Based Paint (LBP)
Program Certification Application for Individuals and we are pleased to inform you that your application has been approved. Your new LBP program individual certification card is enclosed with this letter and this card is the sole method of individual certification documentation that you will receive from the DAQ.
Please check the information on your LBP program certification card carefully. Please confirm that the photograph, name, and certification discipline(s) are correct. Also, please remember to keep your current LBP program certification card with you at all times when you are performing regulated LBP work activities.
Please contact Barbara Perkins at (80 l) 536-0221 or at bperkins@utah.gov if you have any questions regarding this letter or the enclosed LBP program certification card.
Sincerely, ~ Sl1J~ Leonard Wright (Feb 7, 2025 12:09 MST)
Leonard Wright, Manager Air Toxics, Lead-Based Paint, and Asbestos Section
LW:BP:lr
195 Nonh 1950 Wes,, 4~' Hoor • Sall Lake City, Ur Mailing Addrm l' 0 llo"< 144820 • Suh Lnl.c Cny. UT 84114-1820
'I elephone (80 I) 536-4000 • l·a"< (801) 536-4099 ·TDD (80 I) 536-1-11-1 ~• u ,, di:tJ mnh gm•
P11111cd on I00~. 1ccycled papc, LIMITED LEAD-BASED PAINT INSPECTION
UTAH STATE DEVELOPMENTAL CENTER
RAINTREE BUILDING
State of Utah
Department of Administrative Services
Division of Facilities Construction and Management (DFCM)
State Office Building Room 4110
47 West 9000 South, Suite #2
Sandy, Utah 84070
Phone (801) 541-1035
LIMITED LEAD-BASED PAINT INSPECTION
UTAH STATE DEVELOPMENTAL CENTER
TABLE OF CONTENTS
TITLE PAGE
1.0 Introduction
2.0 Building Description
3.0 Lead-based Paint Definition
4.0 Procedures
4.1 Paint Sampling Methods
4.2 XRF Calibration
4.3 Field Documentation
5.0 Findings
6.0 Results and Recommendation
8.0 Limitations and Exclusion of Warranty
Appendices
A. Data Tables
Table 1 – Building Component with Lead Levels at 0.3 mg/cm2 and above
Table 2 – Building Component with Lead Levels at below 0.3 mg/cm2
B. Photograph Log
USDC Limited Lead-Based Paint Inspection
State of Utah DFCM Page 1
Limited Lead-Based Paint Inspection
UTAH STATE DEVELOPMENTAL CENTER
1.0 INTRODUCTION
During the month of August 2025, a limited lead-based paint (LBP) survey was conducted for the Utah State Developmental Center, Raintree Building.