526-21-120_100BD-STAMPED_DRAWINGS-P2-COMBINED.pdf
PDF 16 MB Posted
- Solicitation number
- 36C24226B0024
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A I -
B
C
D
E
F
VA FORM 08- 6231
N·� 01-.... ...J
OII
<( u
L!J 11-L!J <( (/)I� ....._,_1=
2 3 4
5 6 7
EMOLITION PLAN LEGEND
.::1=="""""'t=
EXISTING PARTITION TO
REMAIN
EXISTING PARTITION TO BE
REMOVED
EXISTING SLIDING DOOR TO BE
REMOVED
u fi:-Jl
EXISTING FIXTURES TO BE
REMOVED
DESCRIPTIVE NOTE FOR AREA TO
BE REMOVED
AREA NOT IN CONTRACT
I' �� � v QI
EXISTING FIXTURES TO
REMAIN 1111
I•• II
I
SHARED 1
BATHROOM
l1E-102AI II
II
----7 IU
I I
A- !--l�JI I 1-NSSi
:!Pf.I
2 BED
ROOM
l1E-102I
ENLARGED DEMOLITION PARTIAL 1ST FLOOR PLAN
1/8" = 1'-0"
="°"-cc
2 BED
ROOM
I 1E-104 I /2) ..
I BATHROOM HARED
// I SHARED /4' /
/ l1E-104AI 1
{THROOM I,If !t E-106AI I ,..._ /./ _ I _I
/I \.!_)-" " r---/11 /;Jr!. ---., !� ! lc\_ I �"/iv I \"_,r--·· I/ I
--' �l-.1,j� 1
@V" ',"-©
:n
POSE
2 BED
ROOM
I 1E-106 I
= "°""----c., = oo---�
2 BED
ROOM
I 1E-108 I .r0 f BATHROOM ARED
M I
1 SHARED
/ l1E-108A! THROO I 1/ l1E-112AI I@A ; , . I
I r----,-.� .
I ;::11!7!-----
\2_, r-
•·---j----11 l I/ /�
� I 4/J v/ I �
• ./::!f,_ ..JlJ I 1 r-\ I,/ CLEAN '·,"-'::D
� LINEN \.
2 BED
ROOM
I 1E-112 I
= oo-------c., 2 BED
ROOM
l1E-114I
;/I SHARED
ARED I BATHROOM
THROOM 1/1 l1E-114AI l1E-116AI /
2 BED
ROOM
l1E-110I
I 1 :
I • ,.. ___ -r-ri, .
I � / /0/,r---J I ' ' /2
I 1E-116 I 2 BED
ROOM
l1E-118I / \ r,;\_ SHARED
� BATHROOM
I
"'I
OFFICE
1· tE-133 I
', l1E-134AI /2
1,-.___ u /0/ 7 J 2 BED 0 "r-/::/"l 1 1 , ROOM
0---· ' :ftc)LJ n / , 1 • 7�.J l@✓- "-,�'D
REC
THE
CLEAN
LINEN
t:?
l1E-130I
' .- ' .... "'"' ©-·-+--:eT; ,r1,�- , , TYP.
CORRIDOR
I C1-34 I
CORRIDOR
I C1-35 I
1/I SHARE •
I BATHRO
� _) ,..ltE.;_1 1 BAI
W' / ---rh, I jCJl1 (5\-----/_-l} ,I, \..:....J
-- .. t::f.._ I... IJ
_I -Ii
©-I
DIF1ec:rOR %ii 1/J
. Sl.DRC. . Ill cl-iiil
Cl,, .DIETI'f'lAtf Ota@J
PATIENT
1ceMPUTER
ROOM·•·
I 1e'.J2Q l
PMS
ROOM·.
1E-1n;1
:17t,__ l.@
1E-134I ��_'".\-""J
2 BED
ROOM
l1E-13ZI
@1 L ___ °'tli;o 1,_!-@
I • I /
/2 lf/.J--- �
I SHARED
!J ED f 1
1 BATHR
��/ ;�::ooM /
2 BED
� 13
�I . �-,,�, j'·.
Rr #2
CONSULTANT
11E-13 I/ / l1E-128AI '/ ROOM Lb ..J , ,rn,, Cc-... �- '.---. �
2 BED
ROOM
I 1E-126 I
ROOM / /,,.�l1E-124BI (. '11111/ •
0---�/T��@M r:\ /H'i L---���1'1¢.1
\2.r
LOCKER -=,,_7/ia ·/ f SHARED ROOM ,!'l', I BATHROOM 11 E-124 I i ELECTRIC l1E-126A]
ROOM
_ /4 I 1E-171 I
-----=--- ffi'l=�----,4111/ """·
5'-0" r s"fAIAS l/ (jz.·1/f
"'l'!:7•, ... , -- , ... ·, 'ti'. -----
--- ·1-.
-"--' n
I '
\.. .. ' 1 'I ' - ---- \ \ \ , ; r--..J I
--- \ ' ..0 \
- ----- \ i c_..., l.--i---- 5:
----,-___ 's \ -------
� -.J -\_..----- -�� - ------r----_, L1, --.._J
�ION 1 - DEMO E-WING PATIENT RESTROOMS
A
KEY PLAN
NOT TO SCALE 0�
ARCHITECT/ENGINEER OF RECORD
Drawing THle Phase
9 10
ENERAL DEMOLITION PLAN NOTES
A CONTRACTOR SHALL COORDINATE DEMOLITION WORK WITH ALL TRADES, FOR ITEMS SHOWN TO BE
REMOVED ON THIS PLAN. GENERAL CONTRACTOR SHALL ALSO COORDINATE WITH ALL TRADES, THE REMOVAL REINSTALLATION, AND/OR REWORKING OF THE EXISTING FINISHES AS REQUIRED FOR THE
ROUTING OF EXISTING/NEW SERVICES INTO THE PROJECT AREA.
B. PRIOR TO THE START OF DEMOLITION, CONTRACTOR SHALL WALK TO SPACE WITH THE ARCHITECT AND
COR TO IDENTIFY ANY ITEMS TO BE TURNED OVER TO THE GOVERNMENT.
C. CONTRACTOR SHALL REMOVE ALL WINDOW COVERING AND ACCESSORIES COMPLETE.
D. ANY ITEMS DAMAGED BY THE CONTRACTOR OR BY PERSONS UNDER THE SUPERVISION OF THE
CONTRACTOR THAT ARE NOT INDICATED TO BE REMOVED OR DEMOLISHED SHALL BE
REPAIRED/REPLACED TO LIKE NEW CONDITION AT THE CONTRACTORS EXPENSE.
E. REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION.
F. CONTRACTOR SHALL PROVIDE NEGATIVE AIR PRESSURE IN THE AREA BEING MODIFIED TO PREVENT THE SPREAD OF AIRBORNE DUST/PARTICLES TO OTHER OCCUPIED AREAS OF THE MEDICAL CENTER, SEE
SPECIFICATIONS .
G. GENERAL CONTRACTOR SHALL PROVIDE CONSTRUCTION AND WARNING SIGNS AS PER THE
SPECIFICATIONS.
H. CONTRACTOR SHALL MAINTAIN THE EXISTING BUILDING IN A WATERTIGHT STATE THROUGHOUT CONSTRUCTION. ANY DAMAGE CAUSED BY THE CONTRACTOR SHALL BE REPAIRED TO BE LIKE NEW AND
SHALL MATCH NEW CONSTRUCTION.
I. CONTRACTOR SHALL MAINTAIN A FULLY SEALED ENTRY POINTS TO THE ROOMS AND/OR AREAS BEING RENOVATED. ROOMS MUST BE SEALED TO PREVENT THE TRANSFER OF DUST AND DEBRIS TO ADJACENT
SPACES.
J. GENERAL CONTRACTOR SHALL MAINTAIN WALK-OFF (STICKY) MATS ON BOTH SIDES OF THE ENTRY
POINTS TO THE ROOMS AND/OR AREAS BEING RENOVATED. CHANGE MATS REGULARLY AND AS
DIRECTED BY THE VA INFECTION CONTROL STAFF TO PREVENT THE TRANSFER OF FOOT TRAFFIC DUST
AND DEBRIS.
K. UNLESS OTHERWISE INDICATED ON FIRE PROTECTION DRAWINGS THE EXISTING SPRINKLER SYSTEM SHALL REMAIN LIVE AND FUNCTIONAL DURING ALL PHASES OF CONSTRUCTION. CONTRACTOR SHALL
TAKE GREAT CARE TO NOT DAMAGE ANY EXISTING HEADS OR PIPING,
L. CONTRACTOR SHALL SALVAGE WALL MOUNTED SIGNAGE, CHARTS, MARKERBOARDS, CLOCKS, FURNITURE AND ETC. AND TURN OVER TO THE COR. COORDINATE WORK SCOPE WITH THE VA PRIOR TO START OF
DEMOLITION.
M. CONTRACTOR IS TO DISPOSE OF ALL CONSTRUCTION WASTE IN ACCORDANCE WITH OSHA GUIDELINES.
CONTRACTOR MUST PROVIDE WASTE TICKETS TO ENSURE PROPER CLEANUP.
N. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL REVIEW THE "ASBESTOS ABATEMENT MONITORING REPORT", PREPARED IN FEBRUARY 2018 AND THE "CLEARANCE AIR REPORT" PREPARED IN MARCH 2020, BOTH FOR THE JAMES J. PETERS VAMC, BRONX NEW YORK.
0. THE CONTRACTOR IS RESPONSIBLE FOR REPLACING ANY EXISTING FLOORING IN THE EVENT OF DAMAGE.
REPLACEMENT FLOORING TO MATCH EXISTING.
0 DEMOLITION PLAN KEY NOTES
'NOT ALL KEYED NOTES ARE APPLICABLE TO THIS SHEET, REFER TO ALL DEMOLITION
SHEETS FOR REFERENCE.
1. EXISTING BATHROOM DOORS AND RAILING TO BE REMOVED. PATCH AND REPAIR SURFACES TO RECEIVE
NEW DOOR AND DOOR HARDWARE.
2. EXISTING VANITY AND LAVATORY TO BE REMOVED. PATCH AND REPAIR WALL AND PREP SURFACES TO
RECEIVE NEW VANITY AT LOWER HEIGHT. REFER TO INTERIOR ELEVATION.
3. EXISTING FIRE EXTINGUISHER CABINET TO BE RELOCATED.
4. EXISTING WALL MOUNTED TELEVISION TO BE RELOCATED.
5. EXISTING PATIENT TOILET TO BE RELOCATED FOR NEW PLUMBING BUMP-OUT. REFER TO NEW WORK ON
AE-102.
6. REMOVE EXISTING GRAB BAR MOUNT AND TURN OVER TO THE VA. PATCH AND REPAIR WALL.
7. DEMO EXISTING WALL TO RECEIVE NEW DOOR OPENING. PATCH AND REPAIR EFFECTED ADJACENT
SURFACES.
8. REMOVE EXISTING DOOR AND FRAME COMPLETE
9. DEMO EXISTING SINK, FAUCET AND REMOVE CASEWORK FOR RELOCATION. PATCH AND REPAIR WALL
AND FLOOR
10. DEMO PARTIAL OF EXISTING WALL FOR NEW MANUALLY OPERATED PARTITION WALL SYSTEM POCKET
INSTALLATION OPENING. COORDINATE WITH NEW WORK
11. REMOVE EXISTING SHOWER UNIT AND TRENCH DRAIN AS REQUIRED FOR NEW RESTROOM
CONFIGURATION. COORDINATE WITH NEW WORK
12. REMOVE EXISTING SINK AND COUNTER TOP AS REQUIRED FOR NEW WALL MOUNTED SINK.
13. REMOVE EXISTING WALL PARTITION AS REQUIRED FOR NEW RESTROOM CONFIGURATION
14. REMOVE EXISTING TOILET ACCESSORIES AS REQUIRED FOR NEW WORK. SOME OF EXISTING TOILET
ACCESSORIES TO BE RE-USED AND RELOCATED AS NEEDED FOR NEW RESTROOM CONFIGURATION
CONSTRUCTION. COORDINATE WITH TOILET ACCESSORIES SCHEDULE, NEW ENLARGED PLAN AND NEW
INTERIOR ELEVATIONS.
15. .�REA OF ON-GOING VA PROJECT THfoJ IS NOT ASSOCl.�TED WITH THIS CONTRACT.
Project Title Project Number 526-21-120> lf:to/·�v'• ',!,\fol 4,V rS JAMES J. PETERS
VETERANS AFFAIRS
MEDICAL CENTER
ENLARGED PARTIAL DEMOLITION
FIRST FLOOR PLAN
100% BID DOCUMENTS MODIFY SCI Building Number
Revisions: Date:
1 2 3 4
WEST P □ INT
ENGIN.EERS PLLC
(502)890-2210 * WESTPOINTENGINEERS.COM
1941 BISHOP LANE SUITE 400' LOUISVILLE, KY 40218
i
� ,- "-,:'&,, (J .
,u_'"' •
. "" <C .r -
�""= .-.. o, � a· "'i\
�r - ,O·
VA
U.S. Department of Veterans Affairs
Approved: Project Director
7 8
Location JAMES J. PETERS VA MEDICAL CENTER
130 W KINQSBFIOOE ROAD, BRONX, NY 10468
Issue Date
03-24-2025
Checked
BVG �
L::_J
Drawing Number
AD103
A
B
C
D
E
F
A
B
C
D
E
F
VA FORM 08- 6231
I
! �Q I I I I I I L ___________ _
QJ --L _______________ ,
AOL
AOL
KITCHEN
I 1D-109 I
<0
BATHR
1 D-1
I
� � ,---rr--r -� _ _ _ , -., r--------------------rt'--f _ _ _ _ ___ _J
" 1 raff=,--- • --
I I I ' I
",--.. I
I rr1.-••pI i' 11
Lt!., _�, ------.JJ
DAY
ROOM
I 1D-114 I
��=-=-==a ,r® ______________ _J_ _
ENLARGED DEMOLITION 1ST FLOOR PLAN AT DAY ROOM 1 D-114
318" = 1 '-0"
I
-71 �- I
/II \ :
l��I r
-)1
\\ IJ
,-,p
;?� l�\\:tl _}4 � 1
\_) � 2 I
���_J_�����
+�7 I I
I I
_______ ....,,. _ _j
II
ii I!
i 1 1
I! I ' ' I il µ
:..JI �=--- �
4 REFERENCE ENLARGED DEMOLITION PLAN - AT TYP. SHARED BATHROOM IN EWING
0110 3/8" = 1'-0"
Revisions:
CONSULTANT
Date:
I
\_,I u
I ;_j
_I
I I
L_ ___ _
CT
I I I I
I 9' - O"I
�IL�
Ill II --------
---- Ill II
-- -<I. JI
RESTROOM
l1E-124BI
------ADL--7,,-,,-� :-B,ATHROOM
I - -
! , , --[t D-f09AI 1- , ' - ;, ,_ 1
:,:,©'- -· I 1 4 ' , - I I - ' .J I' , � , ' I l�,-1 _, 1'- ,- ,- I ·-1 .._.,_,.,:__L..:;:_ __. ' - ---
17'-1i"
14'-7" l l
7 8
D
ISJxJ ADL
KITCHEN
I 1D-109 I I 8' - O"I l:sJ
I l
------------ ---------------'l�-----------
I I I I' '
I I I L __ L_J ' ' '' ' ' ' ' '' ' '' ' ' I I I I I I L __ L_J I I I' ' ' ' ' '
F--=----41 II /11 '1. ,, rr----=---
11 0 ,11 ··\I I I I . '..I\ l I l
I I I I I I L __ L...J I I I' ' ' I I I I I I I I I L __ L...J' ' ' I I I' ' ' I I I' ' ' I I I' ' '
L--LJ
I I I 1 '-11" I 1,...-r ,f
L __ L.J' ' '' ' '' ' ' I I I' ' '' ' ' ' ' '
L __ LJ
I I I I I I I I I I I I I I I' ' ' I I I L--L...J' ' ' ' ' ' I I I
•'\I I I I )I I I I -
I I I ' ' ' L __ L...J ' ' '
6'-2" I 1 1 1 I I I' ' ' ' ' ' ' ' ' L __ L...J ' ' ' ' ' '
DAY
ROOM
I 1D-114 I I 9' - O"I
1-:-------:----- -:-----:
�--------i---- ' ' G) ' r.nm-1mrl :i i i I I I I I I l 1 l :1111111111 llf: I I I : : LllllJ_!_llilJ_IIUJ : :
L-L-------L-------L- ____ ...J I I I I I I I I I I I I I I I I I I I I lj\ I I I r I� �-L-------L-------L-----�
II 12'/ II r-..
e II\::._/,; I\ �
II
H I I
11 / !
II / I
II I I
'----==--.....__.....J rr----_-.. .,, II /1
1112' / l 11\!:.../1 I
I
:: / iv '\III / II
II 1 II
II/ II
II/ 11
l.!::-_ -�---JJ
II 2 / II
H / 11
II , II
II / II
II / II
II I II
II/ II
II/ II
�--� --.....JJ
1 ENLARGED DEMOLITION REFLECTED CEILING 1ST FLOOR PLAN AT DAY ROOM 1D-114
,e.0110 318" = 1'-0"
0 DEMOLITION PLAN KEY NOTES
'NOT ALL KEYED NOTES ARE APPLICABLE TO THIS SHEET, REFER TO ALL DEMOLITION
SHEETS FOR REFERENCE.
1. EXISTING BATHROOM DOORS AND RAILING TO BE REMOVED. PATCH AND REPAIR SURFACES TO RECEIVE
NEW DOOR AND DOOR HARDWARE.
2. EXISTING VANITY AND LAVATORY TO BE REMOVED. PATCH AND REPAIR WALL AND PREP SURFACES TO
RECEIVE NEW VANITY AT LOWER HEIGHT. REFER TO INTERIOR ELEVATION.
3. EXISTING FIRE EXTINGUISHER CABINET TO BE RELOCATED.
4. EXISTING WALL MOUNTED TELEVISION TO BE RELOCATED.
5. EXISTING PATIENT TOILET TO BE RELOCATED FOR NEW PLUMBING BUMP-OUT. REFER TO NEW WORK ON
AE-102.
7. DEMO EXISTING WALL TO RECEIVE NEW DOOR OPENING. PATCH AND REPAIR EFFECTED ADJACENT
SURFACES.
8. REMOVE EXISTING DOOR AND FRAME COMPLETE
9. DEMCIT)(]STING SINK, FAUCET ANITPEl\IDVE-c-;,;:s-EWORK FOR RELOCATION. PATCH ANO REPAIR WALL
AND FLOOR.
10. DEMO PARTIAL OF EXISTING WALL FOR NEW MANUALLY OPERA TED PARTITION WALL SYSTEM POCKET
INSTALLATION OPENING. COORDINATE WITH NEW WORK
11. REMOVE EXISTING SHOWER UNIT AND TRENCH DRAIN AS REQUIRED FOR NEW RESTROOM
CONFIGURATION. COORDINATE WITH NEW WORK
12. REMOVE EXISTING SINK AND COUNTER TOP AS REQUIRED FOR NEW WALL MOUNTED SINK.
13. REMOVE EXISTING WALL PARTITION AS REQUIRED FOR NEW RESTROOM CONFIGURATION
CONSTRUCTION. COORDINATE WITH NEW WORK
ENLARGED DEMOLITION PLAN - RESTROOM 1 E-124B 14. REMOVE EXISTING TOILET ACCESSORIES AS REQUIRED FOR NEW WORK. SOME OF EXISTING TOILET
ACCESSORIES TO BE RE-USED AND RELOCATED AS NEEDED FOR NEW RESTROOM CONFIGURATION
CONSTRUCTION. COORDINATE WITH TOILET ACCESSORIES SCHEDULE, NEW ENLARGED PLAN AND NEW
INTERIOR ELEVATIONS.
3/8" = 1 '-011
ARCHITECT/ENGINEER OF RECORD
WEST POINT
ENG'INEERS PLLC
(502)890-2210 • WESTPOINTENGINEERS.COM
1941 BISHOP LANE SUITE 400 • LOUISVILLE, KY 40218
STAMP 1 At!,'C�2•1J' I .1'6;.-iii w"" .�f&�--- \ m ii, fe�I!
,,,❖.�:v· :�,,. ' !�t-
JAMES J. PETERS
VETERANS AFFAIRS
MEDICAL CENTER
VA
U.S. Department of Veterans Affairs
Drawing Title Phase
ENLARGED PARTIAL DEMO PLANS 100% BID DOCUMENTS
Approved: Project Director
7 8
9 10
GENERAL PLAN NOTES
A GENERAL CONTRACTOR TO VERIFY AND MATCH EXISTING PARTITION
THICKNESS WHEN INFILLING/PATCHING EXISTING PARTITIONS.
B. PATCH EXISTING PARTITIONS EFFECTED BY DEMOLITION WORK
SCOPE, TO MATCH ADJACENT EXISTING WORK; PREP WALLS AS
REQUIRED FOR NEW PAINT FINISH.
C. REPAIR AND/OR REPLACE EXISTING SUSPENDED ACOUSTICAL CEILING
SYSTEM. NEW CONSTRUCTION TO MATCH EXISTING WORK.
D. REFER TO PLUMBING SHEET P-501 FOR SCHEDULE OF PLUMBING
FIXTURES.
REFLECTED CEILING PLAN LEGEND
NOTE: NOT ALL SYMBOLS ARE USED IN THIS PROJECT
m EXISTING 2' X 2' ACOUSTICAL TILE CEILING TO REMAIN r----:---·-r--r--i�---+--• .,.... •. �----,I I I I I�---+---+- I ____ � L ... L ... L=r ... J
DEMO ACOUSTICAL TILE CEILING
RECESSED CAN LIGHT, REFER TO ELECTRICAL
EXISTING SPRINKLER HEAD TO REMAIN
C2J
Ir _/�j ..,,-- J
C2J
[ZJ
IS]
EXISTING 2' X 4' LIGHT FIXTURE TO REMAIN
REMOVE 2' X 4' LIGHT FIXTURE
NEW 2' X 4' LIGHT FIXTURE
EXISTING HVAC RETURN TO REMAIN
EXISTING HVAC SUPPLY TO REMAIN
EXISTING EXHAUST AIR GRILLE TO REMAIN
ESeel •=al REMOVE EXHAUST AIR GRILLE TO BE RELOCATED
-�-,:•;,,1;i' ��:::. ,'--.,•' ," n .,;•1 ;.'r;;•;i.�:,i:•( �.: ,;.•>;��·�<.; )!·�.\:!,�
i. t. •lr".:.:·:2;\ "V°"}'.j�,,, ............. ,.
NEW GYPSUM BOARD CEILING/BULKHEAD
EXISTING CEILING/BULKHEAD
GENERAL REFLECTED CEILING PLAN NOTES
A. REFER TO ROOM FINISH SCHEDULE FOR CEILING HEIGHTS.
B REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION ON
LIGHTING AND LAYOUT.
C. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS SUPPL YIRETURN
GRILLS.
D. REFER TO FIRE PROTECTION DRAWINGS FOR LOCATIONS AND
INFORMATION ON SPRINKLER HEADS.
E. REPLACE ALL CEILING TILES AT THE END OF EACH SHIFT. IF TILES
CANNOT BE REPLACED COORDINATE WITH THE COR FOR DIRECTION,
SOME AREAS MAY REQUIRE A 1-HOUR SEPARATION BETWEEN OCCUPIED
SPACES BECAUSE THIS MAY INTERRUPT SPRINKLER SERVICE.
G) DEMO REFLECTED CEILING PLAN KEYNOTES
1. PARTIAL DEMO EXISTING CEILING TILES AND GRIDS FOR NEW
CONTINUOUSLY HINGED MANUALLY OPERA TED PARTITION WALL SYSTEM
INSTALLATION. COORDINATE WITH NEW WORK.
2. REMOVE EXISTING LIGHT FIXTURES. EXISTING SPRINKLER HEADS TO BE
ADJUSTED AND REUSED FOR NEW AOL BEDROOM IF AFFECTED.
COORDINATE WITH NEW WORK, ELECTRICAL AND FIRE PROTECTION.
3. RELOCATE EXISTING RETURN AIR GRILLE AS REQUIRED FOR NEW
AUTOMATED PARTITION WALL SYSTEM POCKET INSTALLATION.
COORDINATE WITH NEW WORK AND MECHANICAL.
PLUMBING DRAWINGS.
Project TIiie
MODIFY SCI
Location JAMES J. PETERS VA MEDICAL CENTER
130 W KINGSSAIOGE ROAD, BRONX, NY 10468
Issue Date 03-24-2025
Checked
BVG
Drawn ws
ATE WITH
Project Number 526-21-120
Building Number
Drawing Number
AD110
A
B
C
D
A
C
D
E
F r
I •• -·- - ' -64
SCI RESIDENT
CENTER
I 10-1221
MECHANICAL
EQUIPME!-lt
ROOM
t iQ I
VA FORM 08 - 6231
= c=----
2 BED\f9:\ ROOM
SHARED '---"'" 1�
'.� -ffo-120 I
B M 6��2��1
M
CORRIDOR
·1c1-32I
EPVA
OFFICE
I 10-1� I
2 BED (,):\\ SHARED
ROOM � BATHROOM
I 10-1 l1D-118AI
PSYCHOl1 [ 1D-121 [
;YCHOU
= c=----
--= c=----
SHARED \\('t
BATHROOM �' •
l1D-116AI
2 BED
ROOM
I 10-116 I i J
BiJIPMENT
STORAGE
!10-117[
'ECIAU
I 10-13
--= c=----
--= c=----
SHARED
2 BED � BATHROOM
ROOM \¼]' [1D-114AI
[ 1D-114
3/-\
SHARED
BATHROOM
110-110Aj
I
2 BED
ROOM
l1D-110I i J
-1/--;:::=-,-
2 BED
l'I\ ROOM <1. (1 11D-108].__ , I
SHARED
BATHROOM
l1D-108AI
2 BED
ROOM
l1D-106I SHARED '\:,[;;
BATHROOM �\'a.
l1D-106AI i J
CLEAN
LINEN
110-1121 � E-11E-10 \,,------
AOL
KITCHEN
11D-1091 o
CORRIDOR
I C1-33 I
1i}133[
CHARTING \\\
OFFICE
110:135 I ,1 __ 11□-137 I
AOL
BATHROOM
\ DAY
ROOM
110-1141
' I I \, .
t t '\ 1\ ,,•.
'\ 'i
• I . , I \ • • ' \
CORRIO� 115'-
\1
AOL
BEDROOM
l1D-109BI �
I C1-30 \
"' l \ 110J c;;1 "'\� ,,,,, 6'-'t - -\ \�"1 11 �-
II
2 BED
ROOM 11\� SHARED
I 1D-104 I \gl: BATHROOM r l1D-104AI
CORRIDOR
I C1-338 I
CYSTdscoPY l1@o1 um e, ,• =l'ffl"t
NURSE
STATION
110-1a I r&.
,;M, �· N -. 0....J ...- I
I w
(_) <l'.
1--1 w<l'. w2 ■ (J)
"ii
;JI
SHARED '®
BATHROOM : §1
l1E-102AI p- 7
----i 1' /
I
I
I
I
I
I
I
I l•i
I •I
1: I I •I
I
I 1 L -.
'-0
CORRIDOI
I C1-29 I
I
SIR£il'I
EQUII
8 9 10
GENERAL PLAN NOTES
A. GENERAL CONTRACTOR TO VERIFY AND MATCH EXISTING PARTITION
THICKNESS WHEN INFILLING/PATCHING EXISTING PARTITIONS.
B. PATCH EXISTING PARTITIONS EFFECTED BY DEMOLITION WORK
SCOPE, TO MATCH ADJACENT EXISTING WORK; PREP WALLS AS
REQUIRED FOR NEW PAINT FINISH.
C. REPAIR AND/OR REPLACE EXISTING SUSPENDED ACOUSTICAL CEILING
SYSTEM. NEW CONSTRUCTION TO MATCH EXISTING WORK.
D. REFER TO PLUMBING SHEET P-501 FOR SCHEDULE OF PLUMBING
FIXTURES.
REFERENCE PLAN LEGEND
l
ROOM
NAME
1 0000 I
1€>3
0---
ROOM NAME TAG
REFER TO ROOM FINISH SCHEDULE
FOR ADDITIONAL INFORMATION
CODE NOTE TAG
INTERIOR ELEVATION TAG
WALL SECTION TAG
DOOR SCHEDULE TAG
REFER TO DOOR SCHEDULE FOR
ADDITIONAL INFORMATION
WALL TYPE TAG
AREA NOT IN CONTRACT
0 ARCHITECTURAL PLAN KEY NOTES
"NOT All KEYED NOTES ARE APPLICABLE TO THIS SHEET, REFER TO ALL
NEW WORK SHEETS FOR REFERENCE.
1. INSTALL NEW SINGLE PANEL SLIDING PATIENT BATHROOM DOOR WITH ADA
COMPLIANT POWERED OPENER
2. NEW VANITY AND LAVATORY. VANITY TO BE SOLID SURFACE COUNTERTOP, SOLID
SURFACE BACK & SIDE-SPLASH AND SOLID SURFACE FRONT & SIDE SKIRT PANELS
TO MATCH EXISTING IN D-WING FOR SIZE, COLOR AND FINISH. REINFORCE FRONT
SKIRT PANEL TO RECEIVE RECESSED AND SURFACE MOUNTED ACCESSORIES.
VANITY TO HAVE 3 CONCEALED COUNTERTOP SUPPORTS. REFER TO ELEVATION
1/AE202, CASEWORK DETAILS AE701 AND THE SCl/0 DESIGN GUIDE FOR REQUIRED
ACCESSORIES ANO ADDITIONAL INFORMATION.
! 1D-1291
CLEAN
LINEN
CORRIDOR
I C1-31 I
SHARED
,,..,.-- STORAGE
I 1D-140 I /©1
CYSTOSCOPY
I 10-141)
Ol'F.ICE
I
I
I
I
I
I
• d
S-r.� ... • ii;'
3. RELOCATED EXISTING PATIENT TOILET. REFER TO PLUMBING SHEET P-102 FOR
ADDITIONAL INFORMATION.
4. NEW PLUMBING BUMP OUT, 9" DEEP, 2'-1" HIGH AND 1'-6" WIDE TO MATCH D-WING
IN SIZE AND FINISHES. REFER TO THE SCIID DESIGN GUIDE FOR ADDITIONAL
INFORMATION.
STAIR
I P I
ELECTRTC
ROOM
I 1D-163 I
11'1'.JSI�
2 BED
'?, ROOM
SHARED
BATHROOM
110-12aA1
REFERENCE PARTIAL ENLARGED 1ST FLOOR PLAN
1/8" a 1'-0"
Revisions: Date:
I 1D-132 I t SHARED
L- BATHROOM
2 BED �\ l1D-130AI
ROOM
[ 1D-130 I
�\ \Ml,-.� ..,� '!,a=
CONSULTANT
SHARED \®,
2 BED
BATHROOM :� ROOM
l1D-134AI \ 11D-134[
2 BEP
ROOM-°
j 1D-136 I
\ BATHROOM
l1D-136AI
I I ,·
Ji!�·
-4.�
ARCHITECT/ENGINEER OF RECORD
WEST P □ INT
ENGINEERS PLLC
(502)890-2210 • WESTPOINTENGINEERS.COM
1941 BISHOP LANE SUITE 400 • LOUISVILLE, KY 40218
STAMP I 9 11,,_,,,
lli/lCI:.
n ,v�
1 3 c.nriv
Drawing Title
I
- M
1 1,Ji I
I= �n-
. ;'-';'�[): I - -
LJ
-�. 11fl
5. RELOCATED CASEWORK WITH NEW SINK AND FAUCET. REFER TO PLUMBING
SHEET P-101 FOR ADDITIONAL IN FORMATION.
6. NEW 1 HR RATED DOOR, FRAME AND HARDWARE SET, MATCH EXISTING AOL
KITCHEN DOOR, FRAME AND HARDWARE SET.
7. NEW CONTINUOUSLY HINGED MANUALLY OPERATED PARTITION WALL SYSTEM.
REFER TO SPECIFICATION 10 22 26 OPERABLE PARTITION FOR ADDITIONAL
INFORMATION.
8. NEW CEILING MOUNTED PATIENT LIFT SYSTEM. CONTRACTOR TO PROVIDE
STRUCTURAL DESIGN PER SPECIFICATION 11 73 00 CEILING MOUNTED PATIENT
LIFT SYSTEM. REFER TO SHEET AE110 FOR MORE INFORMATION .
9. RE-LOCATED EXISTING FIRE EXTINGUISHER CABINET. REFER TO ADA GUIDELINES
FOR MOUNTING HEIGHT.
10. VA PROVIDED BED FOR NEW AOL BEDROOM.
11. NEW 1 HR RATED WALL PARTITION. 3-5/8" METAL STUD WITH 1 LAYER OF TYPE "X"
GWB ON EACH SIDE, SECURE AND SEAL TO UNDERSIDE OF DECK. INFILL WITH
SOUND ATTENUATION BATT INSULATION. STORAGE ROOM SIDE TO HAVE FINISH,
PAINT AND BASE MATCHING ADJACENT WALLS.
12. VA PROVIDED ROLL-AWAY WARDROBE, AS NEEDED.
13. NEW TOILET FIXTURE AND SINK. INCLUDING TOILET ACCESSORIES. REFER TO
! H
J
11 INTcRIOIZl:tE'1AT!Or-r,MOUNTffJG'REIGH I ANDl 'ID�B'ING FOR ADDITIONAL ,lo • INFORMATION z I"' ... I I 1::il;:?�
IIW
o I <i:I- w <i: I w � (J)
D
�3 \ --�� - -�----- _;,,_ -----
�-i-
'C_j) A KEY PLAN
NOTTO SCALE
ENLARGED PARTIAL NEW WORK
FIRST FLOOR PLAN
Phase
100% BID DOCUMENTS
14. NEW FLOOR TO MATCH RESTROOM 1D-126A IN D-WING. PATCH AND REPAIR DEMO
WORK PRIOR TO NEW WORK.
15. RELOCATED EXISTING WALL MOUNTED TELEVISION WITH NEW ASSOCIATED
ELECTRICAL AND CABLE CONNECTIONS. COR TO VERIFY LOCATION.
16. NEW VA PROVIDED WALL MOUNTED TELEVISION WITH NEW ASSOCIATED
ELECTRICAL AND CABLE CONNECTIONS. MOUNT AT 60" OF.F., CONTRACTOR TO
INSTALL. COR TO VERIFY LOCATION.
17. AREA OF ON-GOING VA PROJECT THAT IS NOT ASSOCIATED WITH THIS CONTRACT.
Project Title Project Number 526-21-120
MODIFY SCI Building Number
JAMES J. PETERS
VETERANS AFFAIRS
MEDICAL CENTER Approved: Project Director Location JAMES J. PETERS VA MEDICAL CENTER
130 W KINGSBAIDGE ROAD, BRONX, NY 10468
Drawing Number
VA
U.S. Department of Veterans Affairs
7 8
Issue Date
03-24-2025
Checked
BVG
Drawn ws
AE101
A
B
C
D
C
D
E
F
I
!JI
l� sPT(ON::..., ... ,.
VA FORM 08 - 6231
.... I� � I ::::i W
I I
C/) ■ '.2:
l!!J!I == rl I l
SHARED ;
� BATHROOM i � l1E-102AI : e
2 BED
ROOM
I 1E-102 I
----7 I /
I I .
I
'R £•1�''-0
I I I 11:br,.,,_, I
1· I ,1
I I I I
CORRIDO
I I C1-29 I tJnRri�1 "'·:,.
I I I I I I I
...J
'IPT1
le-U I �
INJURY
·GIJWlc
1,I;
p " ] LU I :::r: IIB' •. ; . , ., -. -e :M1 ' - fa.,-, . :'¥C . . • I
<( I oLU I-
LU I <(C/) 2:
3 4 5 6
= :oc--__,, :0,-.. �-=
2 BED
ROOM
;/ 11E-104 I /41/ SHARED / I/,fJ/ BATHROOM 'A
HARED
r-- --, l1E-104AI , ATHRooM lrt\ 1/ / , l1E-106Aj .
r-- ___ / /
Hf
,' rt?r1-,-
-_ I , I . -
Ly-�
2 BED
ROOM
2 BED r0
=:cc,._ �
ROOM f ;/ I 1E-108 I /j)/ SHARED /_I ,.._ (:0 BATHROOM n
HARED
2 BED \ -c_/
1/
11 E-100AI I ATHROOM ,1/B'i ROOM / l1E-112Aj
'W I 1E-112 Ir-- ... _ ,' I , 1-Q'.
2 BED
ROOM
= c:,--._ -----:, ="'"----.c:c "=
)---7-" ,' /j-ff!r
., ----, t 3 / ___j_-,{j 0. 0 r- 1/ ©-· e· -rr-;
r ,.C:3 / '-< 1
I 1E-114 I _/J) /J<l; SHARED /!
r-- ['½' BATHROOM
ARED
SHARED
r,;\ BATHROOM 'c/\_ l1E-134AI /
0-- ,i'c,- -
- --, 1m \
'0/.._ ,' -2.jjED, :/4) ROOM 4 r,l:,,J-Fi , W 11E-134 I
'/-lr--'s.
I - ,/�LEANl(9--- LINEN
[1E-1101
C'RE
-16'
TE,
CLEAN
LINEN
l1E 130�---<4
E-12 s,_�i· D ,,_ -1 i ____ i . o_;-� 3 /{ j /
: ---__, I...:; � ' 2 BED
(i!v SHARED/ I D
ROOM jv,l O S ARE I 1E-132 I ·1 BATH�3�A, BAT ROOM l!"!'!J) 2 BED
11 E- 1 E 128A liftf!!J ROOM
I 1E-128 I l1E-114AI /ll'�THROOM
/ 11 E-116AI /!,
CORRIDOR
I Cf-34 I
CORRIDOR
I C1-35 I
2 BED
ROOM
r- ...... _
13/ -• REST,/ ! /
IRQ
O _iilT.J @;...._1E-124B
/4 j
2 BED ,
...... � 4 ROOM , -:-----f:}� j I 1E-126 I 4 __; --_,'___v O
/l=3/ !r, t.___ 2 �
- LOCKER11)
L
SHARED
BATHROOM
l1E-126AI
ROOM
/ l1E-124I
/4 j =-J ,_
= :0,-.. --=
2 BED r0 ROOM !J<l,, I 1E-1)8l }jj,fi' f SHARE I BATHRO�M f\'itE--118
ELECTRIC A
ROOM
I 1E-171 I /j
A
I f' ,, jl
.r ,, " -_,._
IP:
-. ROOM
REFERENCE PARTIAL ENLARGED 1ST FLOOR PLAN
118" = 1 '-0''
CONSULTANT
Revisions: Date:
1 2 3 4
ARCHITECT/ENGINEER OF RECORD
WEST POINT
ENGINEERS PLLC
(502)890-2210 • WESTPOINTENGINEERS.COM
1941 BISHOP LANE SUITE 400 • LOUISVILLE,. KY 40218
STAM,, u J,,�..Lo:,, Qr NE�,,..,-,,.., I. V,,q
;��\ (j) 0: ' "' m ., , i\ !.rt l--' 1'� iir.·..,_ ,;,-r,e JI 2t};
f (.,, .. 75 79,,,-,<' "' '"'-�-- ti-:"❖ 'f.':;::��•◊ µ � 1Y
' "'fl' -¾-"�. ,, JAMES J, PETERS
VETERANS AFFAIRS
MEDICAL CENTER
VA
U,S. Department of Veterans Affairs
Drawing Title
---- \ ,- \ \ ;- / ------------------- I I \ \ / / ---
\ \ � \ L ,-"'"J -1 \_.___) L--' -�✓ /
I _,._;-, �---- I \_..----- \, L ----r----. -.,, _ _...-........ 1 -.J
KEY PLAN
A NOT TO SCALE
ENLARGED PARTIAL NEW WORK
FIRST FLOOR PLAN
Phase
0�
100% BID DOCUMENTS
Approved: Project Director
7 8
9 10
GENERAL PLAN NOTES
A, GENERAL CONTRACTOR TO VERIFY AND MATCH EXISTING PARTITION
THICKNESS WHEN INFILLING/PATCHING EXISTING PARTITIONS,
B. PATCH EXISTING PARTITIONS EFFECTED BY DEMOLITION WORK
SCOPE, TO MATCH ADJACENT EXISTING WORK; PREP WALLS AS
REQUIRED FOR NEW PAINT FINISH.
C. REPAIR AND/OR REPLACE EXISTING SUSPENDED ACOUSTICAL CEILING
SYSTEM, NEW CONSTRUCTION TO MATCH EXISTING WORK.
D. REFER TO PLUMBING SHEET P-501 FOR SCHEDULE OF PLUMBING
FIXTURES.
REFERENCE PLAN LEGEND
ROOM ROOM NAME TAG
NAME
1 0000 1
REFER TO ROOM FINISH SCHEDULE
FOR ADDITIONAL INFORMATION
w
1�3
I
CODE NOTE TAG
INTERIOR ELEVATION TAG
WALL SECTION TAG
DOOR SCHEDULE TAG
REFER TO DOOR SCHEDULE FOR
ADDITIONAL INFORMATION
WALL TYPE TAG
AREA NOT IN CONTRACT
0 ARCHITECTURAL PLAN KEY NOTES
•NOT ALL KEYED NOTES ARE APPLICABLE TO THIS SHEET, REFER TO ALL
NEW WORK SHEETS FOR REFERENCE.
1. INSTALL NEW SINGLE PANEL SLIDING PATIENT BATHROOM DOOR WITH ADA
COMPLIANT POWERED OPENER.
2. NEW VANITY AND LAVATORY. VANITY TO BE SOLID SURFACE COUNTERTOP, SOLID
SURFACE BACK & SIDE-SPLASH AND SOLID SURFACE FRONT & SIDE SKIRT PANELS
TO MATCH EXISTING IN D-WING FOR SIZE, COLOR AND FINISH. REINFORCE FRONT
SKIRT PANEL TO RECEIVE RECESSED AND SURFACE MOUNTED ACCESSORIES.
VANITY TO HAVE 3 CONCEALED COUNTERTOP SUPPORTS. REFER TO ELEVATION
1/AE202, CASEWORK DETAILS AE701 AND THE SCIID DESIGN GUIDE FOR REQUIRED
ACCESSORIES AND ADDITIONAL INFORMATION.
3. RELOCATED EXISTING PATIENT TOILET. REFER TO PLUMBING SHEET P-102 FOR
ADDITIONAL INFORMATION.
4. NEW PLUMBING BUMP OUT, 9" DEEP, 2'-1" HIGH AND 1'-6" WIDE TO MATCH D-WING
IN SIZE AND FINISHES. REFER TO THE SCI/D DESIGN GUIDE FOR ADDITIONAL
INFORMATION.
5. RELOCATED CASEWORK WITH NEW SINK AND FAUCET. REFER TO PLUMBING
SHEET P-101 FOR ADDITIONAL INFORMATION.
6, NEW 1 HR RATED DOOR, FRAME AND HARDWARE SET, MATCH EXISTING AOL
KITCHEN DOOR, FRAME AND HARDWARE SET.
7. NEW CONTINUOUSLY HINGED MANUALLY OPERATED PARTITION WALL SYSTEM.
REFER TO SPECIFICATION 10 22 26 OPERABLE PARTITION FOR ADDITIONAL
INFORMATION.
8. NEW CEILING MOUNTED PATIENT LIFT SYSTEM. CONTRACTOR TO PROVIDE
STRUCTURAL DESIGN PER SPECIFICATION 11 73 00 CEILING MOUNTED PATIENT
LIFT SYSTEM. REFER TO SHEET AE110 FOR MORE INFORMATION.
9. RE-LOCATED EXISTING FIRE EXTINGUISHER CABINET, REFER TO ADA GUIDELINES
FOR MOUNTING HEIGHT.
10. VA PROVIDED BED FOR NEW AOL BEDROOM.
11. NEW 1 HR RATED WALL PARTITION. 3-5/8" METAL STUD WITH 1 LAYER OF TYPE "X"
GWB ON EACH SIDE, SECURE AND SEAL TO UNDERSIDE OF DECK INFILL WITH
SOUND ATTENUATION BATT INSULATION. STORAGE ROOM SIDE TO HAVE FINISH,
PAINT AND BASE MATCHING ADJACENT WALLS,
12. VA PROVIDED ROLL-AWAY WARDROBE, AS NEEDED.
13. NEW TOILET FIXTURE AND SINK, INCLUDING TOILET ACCESSORIES. REFER TO
INTERIOR ELEVATION, MOUNTING HEIGHT AND PLUMBING FOR ADDITIONAL
INFORMATION
14, NEW FLOOR TO MATCH RESTROOM 1D-126A IN D-WING. PATCH AND REPAIR DEMO
WORK PRIOR TO NEW WORK.
15. RELOCATED EXISTING WALL MOUNTED TELEVISION WITH NEW ASSOCIATED
ELECTRICAL AND CABLE CONNECTIONS, COR TO VERIFY LOCATION,
16. NEW VA PROVIDED WALL MOUNTED TELEVISION WITH NEW ASSOCIATED
ELECTRICAL AND CABLE CONNECTIONS. MOUNT AT 60" O,F,F,, CONTRACTOR TO
INSTALL COR TO VERIFY LOCATION.
17, AREA OF ON-GOING VA PROJECT THAT IS NOT ASSOCIATED WITH THIS CONTRACT.
Project Title
MODIFY SCI
Location JAMES J. PETERS VA ME[)CAL CENTER 130 W Kl1GSB�DGE ROAD, BAQNJs NY 10468
Issue Date
03-24-2025
Cfiecked
BVG
Drawn ws
Project Number 526-21-120
Building Number
Drawing Number
AE102
A
B
C
D
C
D
E
F
�£101
[ I
I
/ a '-""" _jL -':J.1- - -ti !
f----,l L--fl rl
I I 'j I I I I I I
4 \ I I
\I I
I I
I\\ I I I l/) ____ !
�E202
J�----_J
REST
ROOM
l1E-124BI m\ RIil
REFERENCE ENLARGED 1ST FLOOR PLAN AT REST ROOM 1E-124B
3J.811 =-1'-0"
I j[ 0
D D
1�
SHeE□
.T),ROOM
,,1t-128A
I D
I ----- I I I I
� Ill�I I I
� 1
:..J if nu.:
l·[
AOL
BATHROOM
[D 11 D-109AI
Q..Jl.Q f'";==-=!
r-······ �=::::::=� ··--1·r'-""" ...
17'-8"
DAY
ROOM
10-1
�=::::=j
" n
IT •• � FF=-=·-·c::· =-·=··=··c,;· F"---,------,..------~--i
--------------tt---
AOL
KITCHEN
I 1D-109 I oo
L _ _J 1! --� , L.._ __ _ ·----
, , , 7 I ii�, �
- - ·1 1D-1098 = r ! , � P,••····••i ···�·····�··· ••••••• l.J , I. �
·1·1 i I I I ' ' , ' n
A.C:1 �/'\
= �----- • . ' . ■ i ■ : ! I : • ' I • •
I
• u • • fl fl ■ "
A II
H
U ft 1Q II . ". ". ". " . " � -
E �0��
����ENCE ENLARGED 1ST FLOOR PLAN -AT TYP. SHARED BATHROOM IN EWING P..-----'I ,, ___ .
I"---� , ___ , i !1
AOL
BEDROOM
11 D-109BI
CONSULTANT
Revisions: Date:
I/A FORM 08- 6231
1 2 3 4 l[� )JI I[-b-:===-� ·-----
··]1
3'•1 M
!i" "
! 3'-1" Li!! <;:.=,===-----·-" __ ,_,..:r I' 1·1
1'1 TTI ' "
TI I
Ii - L ii
, T I r 1 1
I II I w I I i 0 "
' II I I l"I I I H I -
11 6'-2"
REFERENCE ENLARGED 1ST FLOOR PLAN AT AOL BEDROOM 1D-109B
3/8" = 1 '-0"
ARCHITECT/ENGINEER OF RECORD
WEST POINT
ENGINEERS PLLC
(502)890-2210 * WESJPOINTENGINEERS.COM
1941 BISHOP LANE SUITE 400 • LOUISVILLE, KY 40218
STAMP
, �� o 2 f'• oFNE�
·----:t€L� o�,"ii tli'I'- �• ·� l\ ,..,... a: j:.._J·- " ,•J LV I.A " 0 •
. lfl
<"�- - - • j� •·i:$1..-- .c.-·�¥c, -··'i ,.087'51'9 / <it
��t� nt:::,:�
JAMES J. PETERS
VETERANS AFFAIRS
MEDICAL CENTER
VA
U.S. Department of Veterans Affairs
Drawing Title
REFERENCE ENLARGED FIRST FLOOR
PLAN AT MODIFIED ROOMS
Approved: Project Director
I c-,, i.i� <· • •• ,• '1-''P-Mi?ii<�'"i,?J�•
, r:i·?�¥j�f1,� : .. t::
/I '.,, ;-:±,tfo .. ' :'.-'.t:fut:-JC,'./_; ,T,o/;':-1
Phase
100% BID DOCUMENTS
II
9 10
GENERAL PLAN NOTES
A. GENERAL CONTRACTOR TO VERIFY AND MATCH EXISTING PARTITION
THICKNESS WHEN INFILLING/PATCHING EXISTING PARTITIONS.
B. PATCH EXISTING PARTITIONS EFFECTED BY DEMOLITION WORK
SCOPE, TO MATCH ADJACENT EXISTING WORK; PREP WALLS AS
REQUIRED FOR NEW PAINT FINISH.
C. REPAIR AND/OR REPLACE EXISTING SUSPENDED ACOUSTICAL CEILING
SYSTEM. NEW CONSTRUCTION TO MATCH EXISTING WORK.
D. REFER TO PLUMBING SHEET P-501 FOR SCHEDULE OF PLUMBING
FIXTURES.
REFERENCE PLAN LEGEND
I
ROOM
NAME
1 0000 1
(j)-/
1€>3
0--
ROOM NAME TAG
REFER TO ROOM FINISH SCHEDULE
FOR ADDITIONAL INFORMATION
CODE NOTE TAG
INTERIOR ELEVATION TAG
WALL SECTION TAG
DOOR SCHEDULE TAG
REFER TO DOOR SCHEDULE FOR
ADDITIONAL INFORMATION
WALL TYPE TAG
AREA NOT IN CONTRACT
0 ARCHITECTURAL PLAN KEY NOTES
'NOT ALL KEYED NOTES ARE APPLICABLE TO THIS SHEET, REFER TO ALL
NEW WORK SHEETS FOR REFERENCE.
1. INSTALL NEW SINGLE PANEL SLIDING PATIENT BATHROOM DOOR WITH ADA
COMPLIANT POWERED OPENER.
2. NEW VANITY AND LAVATORY. VANITY TO BE SOLID SURFACE COUNTERTOP, SOLID
SURFACE BACK & SIDE-SPLASH AND SOLID SURFACE FRONT & SIDE SKIRT PANELS
TO MATCH EXISTING IN D-WING FOR SIZE, COLOR AND FINISH. REINFORCE FRONT
SKIRT PANEL TO RECEIVE RECESSED AND SURFACE MOUNTED ACCESSORIES.
VANITY TO HAVE 3 CONCEALED COUNTERTOP SUPPORTS. REFER TO ELEVATION
1/AE202, CASEWORK DETAILS AE701 AND THE SCI/D DESIGN GUIDE FOR REQUIRED
ACCESSORIES AND ADDITIONAL INFORMATION.
3. RELOCATED EXISTING PATIENT TOILET. REFER TO PLUMBING SHEET P-102 FOR
4.
5.
ADDITIONAL INFORMATION.
NEW PLUMBING BUMP OUT, 9" DEEP, 2'-1" HIGH AND 1"-6" WIDE TO MATCH D-WING
IN SIZE AND FINISHES. REFER TO THE SCI/D DESIGN GUIDE FOR ADDITIONAL
INFORMATION.
RELOCATED CASEWORK WITH NEW SINK AND FAUCET. REFER TO PLUMBING
SHEET P-101 FOR ADDITIONAL INFORMATION.
6. NEW 1 HR RATED DOOR, FRAME AND HARDWARE SET. MATCH EXISTING ADL
KITCHEN DOOR, FRAME AND HARDWARE SET.
7. NEW CONTINUOUSLY HINGED MANUALLY OPERA TED PARTITION WALL SYSTEM.
REFER TO SPECIFICATION 10 22 26 OPERABLE PARTITION FOR ADDITIONAL
INFORMATION.
8. NEW CEILING MOUNTED PATIENT LIFT SYSTEM. CONTRACTOR TO PROVIDE
STRUCTURAL DESIGN PER SPECIFICATION 11 73 00 CEILING MOUNTED PATIENT
LIFT SYSTEM. REFER TO SHEET AE110 FOR MORE INFORMATION.
9. RE-LOCATED EXISTING FIRE EXTINGUISHER CABINET. REFER TO ADA GUIDELINES
FOR MOUNTING HEIGHT.
10. VA PROVIDED BED FOR NEW AOL BEDROOM.
11. NEW 1 HR RATED WALL PARTITION. 3-518" METAL STUD WITH 1 LAYER OF TYPE "X"
GWB ON EACH SIDE, SECURE AND SEAL TO UNDERSIDE OF DECK. INFILL WITH
SOUND ATTENUATION BATT INSULATION. STORAGE ROOM SIDE TO HAVE FINISH,
PAINT AND BASE MATCHING ADJACENT WALLS.
12. VA PROVIDED ROLL-AWAY WARDROBE, AS NEEDED.
13. NEW TOILET FIXTURE AND SINK. INCLUDING TOILET ACCESSORIES. REFER TO
INTERIOR ELEVATION, MOUNTING HEIGHT AND PLUMBING FOR ADDITIONAL
INFORMATION
14. NEW FLOOR TO MATCH RESTROOM 1D-126A IN D-WING. PATCH AND REPAIR DEMO
WORK PRIOR TO NEW WORK.
15. RELOCATED EXISTING WALL MOUNTED TELEVISION WITH NEW ASSOCIATED
ELECTRICAL AND CABLE CONNECTIONS. COR TO VERIFY LOCATION.
16. NEW VA PROVIDED WALL MOUNTED TELEVISION WITH NEW ASSOCIATED
ELECTRICAL AND CABLE CONNECTIONS. MOUNT AT 60" O.F.F., CONTRACTOR TO
INSTALL. COR TO VERIFY LOCATION.
17. AREA OF ON-GOING VA PROJECT THAT IS NOT ASSOCIATED WITH THIS CONTRACT.
Project Tltle
MODIFY SCI
Location JAMES J. PETERS VA MEDICAL CENTER
130 W KINGSBRIXE ROAD, BRONX, NY 10468
Issue Date 03-24-2025
Checked
BVG
Drawn ws
Project Number 526-21-120
Building Number
Drawing Number
AE103
A
B
C
D
1 2
B
C
D
E
F
IRevisions:
VA FORM 08- 6231 1 i 2
1 5/6" METAL snJDS
FRAMING AT 24" O.C,
EXTEi-10 TO STRUCTURE
ABOVE
1 1/2" BATT
INSULATION FaR SOUND
BAFFLE
2 LAYERS OF 5/8"
GYPSUM BOARD, EXTUlD
TO STRUcnJRE ABOVE
EXISTINC CEIUNG Tl!.ES
TO REMAIN. REPAIR AS
NEEDED FOR NEW WALL
PAITTITION SYSTEM
INSTALLATIOt.l l't . ·-:· ·;, ' "
HANGER RODS TO BOTT0'-'1 OF
FLOOR STRUCTURE ABOVE.
CONTRACTOR TO FlELD \r£RIFT'
D:ISTING CONDITIONS FOR
SECURE SUPPORT. DO NOT
CONNECT TO INTERSTITIAL
FLOOR ASSEMBLY, ONLY
ATTACH TO STEEL BEAMS OR
CONCRETE'.. CONTRACTOR TO
COORDINATE SliOP DRAWINGS
WITH PARTITION WALL
MANUFACTIJRER.
1 5/6' METAL STUDS
FRAMING AT 24' O.C.
EXTEND TO STRUCTURE
'80'1c
..lli,Li.1 � 2 LAYERS OF 5/8" ..;r,f,V- GYPSUM BOARD. EXTEND
TO STRUCTURE ABOVE
ROLL.EA CHAIN
EXISTING CEILING TILES
TO REMAIN. REPAIR AS
NEEDED FOR NEW WALL
PARTITl:'.IN 5YSTEM
INSTALLATION
HANGE:R BRACKET BY
MODrn!IIFOLO
STEEL, 8,1,il.
et:ARJNG TROLLEY
OFF WI-IITE BAKED
ENAMEL SOFFIT TRIM
PAN BY MODERNFOLD
4 5
@ AOL
BATHROOM
..... 110�109AI • I a.
0· l:S:[XJ
AOL
KITCHE
D
I 1D-10911
I a. - o .. 1 I ::::::--:-,,,1
!_d'
'.ji\lf'._
# 14 GIJIDE RAIL
e'R£-P,O,INTED OFF
WHITE
VINYL TOP SEAL [SJ
FINISH FLOOR
-1 .�O"J
V,orro, SCAL eROeDEs
2" OPERATING
CLEARANCE (+.50" /
MANUALLY OPERATED PARTITION WALL SYSTEM DETAIL
1 1/2" = 1'-0"
3 5/8" METAL STUDS
BRACING AT 48" O.C.
MAX. ATTACH TO
STRUCTURE ABOVE
@ I /I
17'-1;·
DAY
ROOM
110-114 I I 9' - O"I
I / I @I 1 1111111 110/ I
I
I
-1¾'i 0/
I I '
@I B
AE110
@ r� / 11
[XJo 0 @
I
AOL
BEDROOM
11 D-109BI
I 9' - O"I
1� /I I / I�.
I ' , I I ,'1 'I I"11 I, 3 5/6» METAL STUDS
FRAMING AT 24" O.C.
EXTEND TO STRUCTURE
ASOVE
0. ·• 1·
• "·, . . ... ,· .. . . '• , •I . - ; •.
·· l'I� .. --n • ·;y j •·
. ' ' ' :I t------L ...... ��-�---------in:,,: s11�,:1·n -� ____
• ii .f� ·<!. hi. • iii
I • ' "-
3 5/8" METAL sruos
FRAMING AT 24" 0.C.
EXTEND TO NEW W.-.LL
METAt. STUDS FRAf.illNG
I I .;!·I I '!
I l"J I I ;
I I,), ....,_ I ti I I;
I '··
5/8"
GYPSUM BOA.RD.
POCKET DOOR
�EXISTING CEILING T1LES
W RD./AI/i. REPAIR AS
NEEDED FOR NEW WALL
PARTITION SYSTEh-1 POCKET
CEILING INSTALLATION
MANUALLY OPERATED WALL SYSTEM POCKET CEILING DETAIL ENLARGED 1ST FLOOR REFLECTED CEILING PLAN AT AOL BEDROOM 1D-109B 11/2" = 1'-0" f' THREADED HANGER RODS
SECURE TO STRUCTURE
A9ovt. CONTRA.CmR TO
FIELO VERIFY EXISTING
CONOlilONS FOR SECURE
SUPPORT. CONTRACTOR TO
COORDINATE SHOP
DRAWINGS WITH PARTITION
WALL MANUtACTURER. ----,,._
� I � I 0
!id �
I I I
�OIJNTING
EXISTING CEIUNG TILES
TO REMAIN. REPAIR K;
NEEDED FOR NEW PATIENT
CElllNG LIFi SYSTE�
INSTALLATION
i\" STEEL STRUT ACROSS WEEi61NG
LOCKING
NUT. TYP.
EXISTING
GALVANIZED
STEEL WEOOING
,;·,,7""�
I, I ,, I +i I
I I, /I
I'""",,., ., LO CKING
NUT, TYP,
4 Sil:/ Qf., i', ir--'L-LOCKING
NUT, ITP.
CEIUNG LIFT
sac
I I I
EXl'STIN(; f'
F18ERBOAAD
PATIENT LIFT SYSTEM DETAIL
1112" = 1'-0"
CONSULTANT
3/8 " = 1 '-0"
II ARCHITECT/ENGINEER OF RECORD II STAMP 1'LJJl!;:.�do;i, Drawing Title
Phase
9 10
GENERAL PLAN NOTES
A GENERAL CONTRACTOR TO VERIFY AND MATCH EXISTING PARTITION
THICKNESS WHEN INFILLING/PATCHING EXISTING PARTITIONS.
8. PATCH EXISTING PARTITIONS EFFECTED BY DEMOLITION WORK
SCOPE, TO MATCH ADJACENT EXISTING WORK; PREP WALLS AS
REQUIRED FOR NEW PAINT FINISH.
C. REPAIR AND/OR REPLACE EXISTING SUSPENDED ACOUSTICAL CEILING
SYSTEM. NEW CONSTRUCTION TO MATCH EXISTING WORK.
D. REFER TO PLUMBING SHEET P-501 FOR SCHEDULE OF PLUMBING
FIXTURES .
REFLECTED CEILING PLAN LEGEND
NOTE: NOT ALL SYMBOLS ARE USED IN THIS PROJECT
m ,_ ______________ _a ' ' I : , : I' ' ' t---+---+--+--- L--.. L ... J._...J .. __ r --:::n l--------- i
[Z]
,•'·,; ,,,., ,/' _'.\ .. -:� .. :--:·•':,1.;,. :,, ,,,, .... ' '":+. �,,.,.,..,_, ., "'- -�-" I � ·-'.i / ).:1-'.·•i .•• ,,,;�•1 .. �"> '•· (·:.."•�••·' I · �;�;;;�/lf��;;17I
EXISTING 2' X 2' ACOUSTICAL TILE CEILING TO REMAIN
DEMO ACOUSTICAL TILE CEILING
RECESSED CAN LIGHT, REFER TO ELECTRICAL
EXISTING SPRINKLER HEAD TO REMAIN
EXISTING 2' X 4' LIGHT FIXTURE TO REMAIN
REMOVE 2' X 4' LIGHT FIXTURE
NEW 2' X 4' LIGHT FIXTURE
EXISTING HVAC RETURN TO REMAIN
EXISTING HVAC SUPPLY TO REMAIN
EXISTING EXHAUST AIR GRILLE TO REMAIN
REMOVE EXHAUST AIR GRILLE TO BE RELOCATED
NEW GYPSUM BOARD CEILING/BULKHEAD
EXISTING CEILING/BULKHEAD
GENERAL REFLECTED CEILING PLAN NOTES
A. REFER TO ROOM FINISH SCHEDULE FOR CEILING HEIGHTS.
B. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION ON
LIGHTING AND LAYOUT.
C. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS SUPPL YIRETURN
GRILLS.
D REFER TO FIRE PROTECTION DRAWINGS FOR LOCATIONS AND
INFORMATION ON SPRINKLER HEADS.
E. REPLACE ALL CEILING TILES AT THE END OF EACH SHIFT. IF TILES
CANNOT BE REPLACED COORDINATE WITH THE COR FOR DIRECTION,
SOME AREAS MAY REQUIRE A 1-HOUR SEPARATION BETWEEN OCCUPIED
SPACES BECAUSE THIS MAY INTERRUPT SPRINKLER SERVICE.
REFLECTED CEILING PLAN KEYNOTES 0
1. NEW GWB DROP SOFFIT AT 8 '-6" HIGH A.F.F. ALIGN AND FLUSH WITH
EXISTING ADJACENT ACT FOR NEW CONTINUOUSLY HINGED MANUALLY
OPERATED PARTITION WALL SYSTEM INSTALLATION. REFER TO WALL
SECTION.
2.
3.
4.
NEW LIGHT FIXTURES FOR NEW AOL BEDROOM, CONTRACTOR PROVIDED.
COORDINATE WITH ELECTRICAL.
NEW GWB CEILING AT 8'-6" HIGH A.F.F. FOR NEW CONTINUOUSLY HINGED
MANUALLY OPERATED PARTITION WALL SYSTEM POCKET INSTALLATION.
REFER TO WALL SECTION.
NEW PATIENT LIFT SYSTEM. REFER TO SPECIFICATION 1173 00 FOR
ADDITIONAL PATIENT LIFT SYSTEM REQUIREMENTS. CONTRACTOR TO
COORDINATE WITH COR FOR CONTRACTOR FURNISHED, CONTRACTOR
INSTALLED (CFCI), BASIS OF DESIGN SUREHANDS 2810 L CEILING LIFT
WITH TRAVERSE RAIL CEILING TRACK SYSTEM. SEE CEILING DETAIL
C/AE110. COORDINATE SHOP DRAWINGS AND INSTALLATION WITH
MANUFACTURER AND COR TO ENSURE FINAL INSTALLATION MEETS
MANUFACTURER'S WARRANTY. SEE DETAIL C/AE-110,
5. NEW GWB CEILING. CEILING HEIGHT AND FINISH TO MATCH
SURROUNDING ADL BATHROOM 1D-109A CEILING.
6. NEW MECHANICAL DIFFUSER. REFER TO MECHANICAL DRAWINGS FOR
TYPE AND ADDITIONAL INFORMATION .
Project Title - --
Project Number 526-21-120N!:11,- JAMES J PETERS ENLARGED FIRST FLOOR REFLECTED ii,i
''o 100% BID DOCUMENTS MODIFY SCI Building Number l□ate:
I 3 I 4
W E ST P □ 'I NT �*;;:;l;;r ··�1
ENGINEERS PLLC �.��,qJ
(502)890-2210 • WESTPOINTENGINEERS.COM
Y:<} ,,,��,_:fl 1941 BISHOP LANE SUITE 400 • LOUISVILLE, KY 40218 �o ili
�s•a\O,,,"';' .
'. �·· .I L Jl .
I 5 I
VETERANS AFFAIRS
MEDICAL CENTER
VA
U.S. Department of Veterans Affairs
6 I
CEILING PLAN AT ADL BEDROOM
Approved: Project Director
7 I 8 I
Location JAMES J. PETERS VA MEDICAL CENTER
130 W KI-JGSBRIDGE ROAD, BRONX, NY 10468
Issue Date Checked I Draw
"ss
03-24-2025 BVG
9 I
I !Drawing Number
11 AE110
A
B
C
D
C
D
E
F f
'�---- .,,,,-. .,11". ...... _ , • . "' J ' ···
WADL BEDROOM CONCEPT MODEL -VIEW 1
... . . g?A/4 .•.4,--.,•hll -r-:T'\ADL_BEDJ�O_QM_COr-JCEPT_MDDEL-VJEW 2
IQ
Revisions:
VA FORM 08 - 6231 1 2
.21.- -
,: '1
_.--:- :;:�--c.
- ----q
• � --::::::i� • , - 0 - - - l
CONSULTANT
Date:
4 5 c-�•
,"i:"
ARCHITECT/ENGINEER OF RECORD
WEST ... POINT
ENGINEERS PLLC
(502)890-2210 • WESTPOINTENGINEERS.COM
1941 BISHOP LANE SUITE 400 • LOUISVILLE, KY 40218
l -·
@AOL BEDROOM CONCEPT MODEL-VIEW 3
'0
Drawing Title
� it•!:·)·
JAMES J. PETERS
VETERANS AFFAIRS
MEDICAL CENTER
ADL BEDROOM CONCEPT MODEL
ro, w !!11 'to
II
"'V � <;,:_, •10• •' ll S D __ ;;:!Jl'.-,,.¢' • • epartment l-
'4�
,, , _ 1 ilv--/" VA of Veterans Affafrs
Approved: Project Director
Phase
100% BID DOCUMENTS
,-re-·· ',,-�
•-e-1'
Project Title
MODIFY SCI
Location JAMES J. PETERS VA MEDICAL CENTER
130 W KINQSMDQE ROAD, BRONX, NY 10468
Issue Date
03-24-2025
Checked
BVG
Drawn ws
A
B
C
D
E
F
Project Nurrilier
526-21-120
Building Number
Drawing Number
AE201
C I
I
E
F
VA FORM 08 - 6231
142>
PROVIDE NEW CERAMIC WALL TILE BELOW
AND PAINTED DRY WALL ABOVE TO MATCH r EXISTING ADJACENT FINISH WALL WHERE THE
EXISTING SHOWER UNIT AND WALL
PARTITION,!$ DEMOLISHED
, " • RE USED EXISTING
I � / WALL MOUNTED LIGHT FIXTURE.r--17/ REFER TO ELECTRICAL
/ TA-3
I
Q w TA-6 \ • TA-5>--1:l r'
I 'f·1
TA-2
I \
EXISTING CERAMIC WALL TILE
FINISH AND PAINTED DRYWALL
ABOVE TO REMAIN. REPAIR,'
'---+---------+----i -J.. REPLACE AS NEEDED AFTER THE
1 '-6• MIN. 1 '-3" MIN.
INTERIOR ELEVATION
�;,��-�.OOM E-1 1248
Revisions:
EXISTING YANITY REMOVAL
Date:
3 4
EXISTING CERAMIC WALL
3'-4"
TILE WALL FINISH AND
PAINTED DRYvVALL ABOVE \
TO REMAIN AS IS
TA-7 /I t
PROVIDE NEW CERAMIC WALL TILE BELOW
AND PAINTED DRYWALL ABOVE TO MATCH
Ir- EXISTING ADJACEr-.. T FINISH WALL WHERE THE
EXISTING SHOWER UNIT IS DEMOLISHED
'°t= I \ �- ----------,LI ' I
TA-2
'°t=�------+-+--+---' ---',- 7"-9�� 1'-0"
I:!
:y-1 " " /:r
I w r"1 ·1
:r I � ,_ 11 _11 �
N
INTERIOR ELEVATION
0 0
6 7
I
INTERIOR ELEVATION
II
5'-0" /L r@
� I
7'-9"-hJ w j
TOILET ACCESSORIES SCHEDULE
ITEM NAME PROVIDED BY
TA-1 42" GRAB BAR CONTR
TA-2 36"GRAB BAR CONTR
TA-3 MIRROR (24W" x 36H") RE-USE EXISTING
TA-4 SOAP DISPENSER RE-USE EXISTING
TA-5 MUL Tl-ROLL TOILET TISSUE DISPENSER RE-USE EXISTING
TA-6 PAPER TOWEL DISPENSER RE-USE EXISTING
TA-7 18" VERTICAL GRAB BAR CONTR
TA-8 TOILET SEAT PAPER COVER DISPENSER RE-USE EXISTING
TA-9 COAT HOOK - DOUBLE CONTR.
GENERAL CONTRACTOR NOTE:
REFERENCE THE VA OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT'S TECHNICAL INFORMATION
LIBRARY (TIL) FOR INFORMATION ON JSN NUMBERS (TIL "BASIS OF DESIGN" EQUIPMENT)
EQUIPMENT/MEDICAL ACCESSORIES NOTES:
INSTALLED BY
CONTR.
CONTR
CONTR.
VA
VA
VA
CONTR.
CONTR
CONTR
I. PROVIDE BLOCKING (3'-5,�" 22GA METAL STUDS) FOR ALL WALL SUPPORTED EQUIPMENT AND MEDICAL ACCESSORIES.
2. CONTRACTOR TO COORDINATE WITH THE COR ON THE FINAL LOCATION(S) ALL EQUIPMENT AND MEDICAL ACCESSORIES.
3. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. SEE SHEETS EP101 & EP102 FOR ELECTRICAL REQUIREMENTS FOR NEW
EQUIPMENT
JSN #
A5109
A1067 A5075
A5082
A5145
INTERIOR ELEVATION
3 \ RESTROOM E-1 1248 E-WING PATIENT SHARED BATHROOM, TYP. ,--,, E-WING PATIENT SHARED BATHROOM, TYP. 4. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. SEE SHEET P-501 FOR PLUMBING SCHEDULE AND DETAILS.
� 3/8" = 1'-0"
CONSULTANT
3 4
3/8" = 1 '-0''
ARCHITECT/ENGINEER OF RECORD
WEST P □ INT
ENGINEERS PLLC
(502)890-2210 • WESTPOINTENGINEERS.COM
1941 BISHOP LANE SUITE 400 • LOUISVILLE, KY 40218
STAM
if'�1;; o .,1 ,' f NE11, '¾.• o >--o /,�"" �1'cJ'"'-V4tv
Q ;p.;._, ;;;, cJ' li;
· "'-ic -/,:'R1,: "1 ,··"' ., CP (!!_,:
�2::•ol•CDw r - .
UJ o5 ·e1,=_ "",;
� cf) ' •• • "'
�,r;, ,, '<i:
n�E-sa\O'ifo.f
Yf(v.W
3/8" = 1 '-0"
I
1-z� / 111,,, :J 1 11 lli
EXISTING CERAMIC WALL
TILE FINISH AND PAINTED
DRYINALL ABOVE TO REMAIN
AS IS
'I I I
, , , �I ' , INTERIOR ELEVATION
RESTROOM E-11248
--fji"
3/8" = 1'-0"
:'-5"
GRAB BA,"! � ---ti
.1'-D" � _j_J'-6"
I'm iv,m
I
� TOILET
� WAL:Q'"N <
I t ,. " 1 r,•.m
JD e----=I ' ---+
0 T' ' i
'UE
� I ��""1 I . L.)._/ 7"9' l j r
�I �=-+---,k--, �r----i-- 't.-� 11'
I J;, [GRABBAR
\ I \< ; '-4,,- �l
L!W/.JORY TOILE7 ,,.,,, '"'"" 1Y1u, EJXTLJRC.: MOUNTING HEIGHTS
MIRROR +7 SOAP
OISPENSER
w i,;
i, ACCESSORY MC\,)NJING HEIGHT_S
+-+'__,_J
0- PAPER TO.'IEL
OISF�NSER
( uIYPICAL FIXTURE MOUNTING HE1C3H_T � 3/8" = 1'-0"
Drawing Title
COATHOOK - -
\ , ---+ l'JOTE
CONTRACTOR SHAi.l PROVIDE ALL
BLOCKING ANO SUPPLEMENTN.. SUPPORT
RE:JUIR:O FOR SECURE A\ID PROPER
INSTALLATION OF TOILET ROOM FIXTURES
AND AGC�SSORIES.
Phase
5. UNLESS OTHERWISE NOTED, INSTALL ALL EQUIPMENT AND MEDICAL ACCESSORIES PER THE VA'S AND MANUFACTURER'S RECOMMENDED
MOUNTING HEIGHTS.
FURNISHED BYI INSTALLED BY
O.F.CJ OWNER (VA) FURNISHED/ CONTRACTOR INSTALLED
0 ARCHITECTURAL PLAN KEY NOTES
'NOT All KEYED NOTES ARE APPLICABLE TO THIS SHEET, REFER TO All
NEW WORK SHEETS FOR REFERENCE.
INSTALL NEW SINGLE PANEL SLIDING PATIENT BATHROOM DOOR WITH ADA
COMPLIANT POWERED OPENER.
2 . NEW VANITY AND LAVATORY. VANITY TO BE SOLID SURFACE COUNTERTOP, SOLID
SURFACE BACK & SIDE-SPLASH AND SOLID SURFACE FRONT & SIDE SKIRT PANELS
TO MATCH EXISTING IN D-WING FOR SIZE, COLOR AND FINISH. REINFORCE FRONT
SKIRT PANEL TO RECEIVE RECESSED AND SURFACE MOUNTED ACCESSORIES.
VANITY TO HAVE 3 CONCEALED COUNTERTOP SUPPORTS. REFER TO ELEVATION
1/AE202, CASEWORK DETAILS AE701 AND THE SCI/D DESIGN GUIDE FOR REQUIRED
ACCESSORIES AND ADDITIONAL INFORMATION.
RELOCATED EXISTING PATIENT TOILET. REFER TO PLUMBING SHEET P-102 FOR
ADDITIONAL INFORMATION.
4. NEW PLUMBING BUMP OUT, 9" DEEP, 2'-1" HIGH AND 1'-6" WIDE TO MATCH D-WING
IN SIZE AND FINISHES. REFER TO THE SCI/D DESIGN GUIDE FOR ADDITIONAL
INFORMATION.
Project Title Project Number
526-21-120
JAMES J. PETERS
VETERANS AFFAIRS
MEDICAL CENTER
INTERIOR ELEVATIONS 100% BID DOCUMENTS MODIFY SCI
Building Number
VA
U.S. Department of Veterans Affairs
Approved: Project Director
7 8
Location JAMES J. PETERS VA MEDICAL CEMER
130 W =BRIOOE ROAD, BRONX, NY 10468
Issue Date
03-24-2025
Checked
BVG
Drawn ws
Drawing Number
AE202
A
B
II c
I D
C
D
E
F
1 2
IBATHROOMI
l PACKAGE w1orn
1 IBATHROOMI
ELECTRIC
SOLENOID
LOCK
' 6"
COMBINED
ACTIVATION/
SAFETY
SENSOR
• ro
HEADER ABOVE �--- !PATIENT ROOMI
/ '-----11 f�����s HEADER ABOVE 7 !PATIENT ROOM I w
LF
FT HAND
11· RIGHT HAl�D
SLIDING DOOR COVER
A
� �=�-� - DOOR JAMB DETAIL
!PATIENT ROOM!
IBATHROOMI �
VA FORM 08 - 6231
w
"'*CONTRACTOR SHALL VERIFY PARTITION THICKNESS
PRIOR TO DETERMINING FRJ!..ME THROAT SIZE
HOLLOW METAL FRAME W /
Z CLIP ANCHORS
I rPARTITION WHERE IT
� OCCURS - SEE PLANS
1 .,,-CAULK, TYP. BOTH SlOE.SI
METAL STUDS
w ' / I I I I 11 I (I 1 1 in ' v- I r ' -( _)(�)1
Ji _-"/ I •--
2" FULL HEIGHT METAL RUNNER
FASTENED TO BOTH
ADJACENT METAL STUDS
STANDARD FRAME
SEE PARTITION TYPE
r ,, 1
, II\../..-.;
I r 111! 1111 r
1 Ii"
FRAME DEPTH
STANDARD FRAME
METAL STUDS
METAL STUD HEAD
FRAMING
CAULK, TYP.
BOTH SIDES
HOLLOW METAL
FRAME W/ Z CLIP
ANCHORS B
SLIDING DOOR
RECESSED
PANIC DEVICE
FRAME WIDrn 4j'
ALUM - DOOR HEAD AND SILL DETAIL
3" = 1'-0"
,-C
1.
�00R JAMB DETAIL ,-O
��f:
�00R HEAD DETAIL
Revisions:
3-5/8" METAL RUNNER
TRACK FASTEN TO
STRUCTURE ABOVE@
24"(MIN.) O.C. DO NOT
SECURE STUDS TO TRACK
SCHEDULED CEILING
V PlJ\N VIEW
LINE OF STRUCTURE
ABOVE
CONTINUOUS SEALANT
EA SIDE (TYPICAL)
INSULATION - SEE
SPECIFICATIONS
3-5/8" METAL STUDS @
16" O.C. MAXIMUM.
ll,t<J:ll- (1)LAYER OF TYPE "x" s/s"
CONTINUOUS SEALANT
EA. SIDE (TYPICAL)�
l 4l" LK '1
JUL# U465- 1 HOURI
NON LOAD BEARING
RATED PARTITION
NOT TO SCALE
GYPSUM BOARD
BASE - SEE FINISH
SCHEDULE FOR TYPE
TRACK RUNNER
FLOOR SLAB
[A]
CONSULTANT
Date:
PARTITION NOTES
A. PARTITION NOTES APPLY TO ALL INTERIOR PARTITIONS CONSTRUCTED FOR THE PROJECT.
B. PARTITION TYPE DRAWINGS INDICATE THE GENERAL RELATIONSHIP AMONG MATERIALS AND
CONSTRUCTION OF PARTITIONS WITHIN THE SCOPE OF WORK.
C. WHERE PARTITION FRAMING MEETS EXISTING STRUCTURE ABOVE, CONTRACTOR SHALL UTILIZE DEFLECTION CLIPS OR SLIP TRACK TO ANCHOR STUDS. (SLIP TRACK IS APPROPRIATE ONLY WHERE A CONSISTENT LEVEL UNINTERRUPTED STRUCTURE EXISTS ABOVE. PROVIDE DEFLECTION CLIPS OF
VARYING TYPE APPROPRIATE FOR THE EXISTING CONDITION ENCOUNTERED WHERE TOP OF
PARTITION MEETS EXISTING CONSTRUCTION. DEFLECTION CLIPS OR SLIP TRACK SHALL PROVIDE FOR
DEFLECTION OF UP TO 3/4".
D. WHERE GYPSUM BOARD IS SHOWN TO EXTEND TO STRUCTURE ABOVE, HOLD THE GYPSUM BOARD 1" BELOW THE LINE OF EXISTING STRUCTURE. (FIRE SEAL ALL SUCH VOIDS IN CONTINUOUS GYPSUM
BOARD WHERE OCCURRING AT FIRE-RATED WALLS.)
ARCHITECT/ENGINEER OF RECORD
WEST P □ INT
ENGINEERS PLLC
(502)890-2210 'WESTPOINTENGINEERS.COM
1941 BISHOP LANE SUITE 400 • LOUISVILLE, KY 40218
STAMP , ���
f of NEW
1,tL VA,v
Q
,pf-\
J " "-i: *) ',., I.J.;- .• .. • .. l, (]> C! ,'* Z, -' ' � ', I m ltJ 'c:�� '�; • I i;�/�,�I -.?'C.,...�' •• ;; �
3J/
�0 t'.f.� .· 0'<;,,087STs���".
,,,�""");,t"·_ / I ���/l_./'-'"
6 7 8
DOOR SCHEDULE
REFER TO SPECIFICATION SECTION 08 71 00 DOOR HARDWARE FOR DOOR HARDWARE SCHEDULE
DOOR ROOM ROOM DOOR
NUMBER NUMBER NAME TYPE WIDTH HEIGHT MATERIAL
ID-104A 1D-104A SHARED BATHROOM D1 4'-1�" 7'-8" ALUM
ID-106A ID-106A SHARED BATHROOM D1 4'-ll" 7'-8" ALUM
1D-108A 10-IOBA SHARED BATHROOM D1 4'-1�'' 7'-8" ALUM
1D-109B 1D-109B ADL ROOM D2 3'-6" 7'-0" SCWD
1D-110A 1D-110A SHARED BATHROOM D1 4'-1t 7'-8" ALUM
1D-114A ID-114A SHARED BATHROOM 01 4•.1;· 7'-8" ALUM
1D·116A 1D-116A SHARED BATHROOM 01 4'-1l" 7'-8" ALUM
1D-118A 1D-118A SHARED BA TH ROOM D1 4'-1�" 7'-8" ALUM
1D-120A 1D-120A SHARED BATHROOM 01 4'-11" 7'-8" ALUM
1D-128A 1D-128A SHARED BATHROOM D1 4'-1�" 7'-8" ALUM
1D-130A 1D-130A SHARED BATHROOM D1 4'-1l· 7'-8" ALUM
1D-134A 1D-134A SHARED BATHROOM D1 4'-1�" 7'-8" ALUM
ID-136A 1D-136A SHARED BATHROOM D1 4'-11" 7'-8" ALUM
IE-102A 1E-102A SHARED BATHROOM 01 4'-11" 7'-8" ALUM
IE-104A 1E-104A SHARED BATHROOM 01 4'-1j" r-8" ALUM
1E-108A 1 E-10BA SHARED BATHROOl\l D1 4'-1l· 7'-8' ALUM
1E-112A 1E-112A SHARED BATHROOM D1 4'-1/" 7'-8� ALUM
1E-114A 1E-114A SHARED BATHROOM D1 4'-1�� 7'-8" ALUM
1E-116A 1E-116A SHARED BATHROOM D1 4'·11" 7'-8" ALUM
1E-118A 1E-118A SHARED BATHROOM D1 4'· 1�" 7'-8" ALUM
1E-126A 1E-126A SHARED BATHROOM D1 4'-1j" 7'-8" ALUM
1E-128A 1E-12BA SHARED BATHROOM 01 4'-1�" 7'-8" ALUM
1E-132A 1E-132A SHARED BATHROOM D1 4' 1j" 7'-8" ALUM
1 E-134A 1E-134A SHARED BATHROOM D1 4'· 11" r-a" ALUM
DOOR SCHEDULE GENERAL NOTES
A UNLESS OTHERWISE NOTED, ALL DOORS SHALL BE MADE READABLY OPERABLE FROM SIDE WHICH EGRESS IS TO BE MADE
WITHOUT A KEY OR SPECIAL KNOWLEDGE.
B. ALL LATCHSETS AND LOCKSETS ARE TO HAVE ADA LEVER HANDLES
C. PROVIDE WALL MOUNTED STOPS WHENEVER POSSIBLE
D. CONTRACTOR TO COORDINATE KEYING WITH THE VA
E. REFER TO SPECIFICATIONS FOR HARDWARE SCHEDULE
F. REFER TO WOOD DOOR SPECIFICATION FOR INFORMATION ON THE WOOD SPECIES AND FINISH
G HARDWARE FINISH TO BE BRUSHED NICKEL- TO MATCH EXISTING
H. SHARED BATHROOM DOOR OPENINGS ARE EXITING AND NEED TO BE FIELD VERIFIED BY CONTRACTOR.
I. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DOOR HEIGHTS AND WIDTHS TO BE COMPLIANT WITH MANUFACTURER.
DOOR SCHEDULE COMMENTS
1. HOLLOW METAL FRAME TO BE PAINTED· TO MATCH EXISTING
2. SOLID CORE WOOD DOOR - FINISH TO MATCH EXISTING
MATERIAL SCHEDULE
HM HOLLOW METAL
SCWD SOLID CORE WOOD
ALUM ALUMINIUM
,/6'1
FINISH FLOOR
TOUCHLESS STAINLESS
STEEL PLATE r(WAVE TO OPEN
DETECTOR)
FINISH FLOOR
L SEE l
-. SCHEDULE "
FLUSH
FRAME
TYPE MATERIAL
ALUM
ALUM
ALUM
F2 HM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUI�
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
HEAD
BIAE601
B/AE601
B/AE601
D/AE601
BIAE601
B/AE601
BIAE601
B/AE601
B/AE601
B/AE601
B/AE601
B/AE601
B/AE601
B/AE601
81AE601
BIAE601
B/AE601
B/AE601
BIAE601
B/AE601
B/AE601
B/AE601
B/AE601
BIAE601
0I
JAMB
AIAE601
AIAE601
AIAE601
C/AE601
AIAE601
AIAE601
A/AE601
A/AE601
AIAE601
A/AE601
A/AE601
A/AE601
A/AE601
AIAE601
AIAE601
AIAE601
AIAE601
A/AE601
A/AE601
A/AE601
AIAE601
AIAE601
A/AE601
AIAE601
* f
L SEE l
, SCHEDULE .,
9 10
SILL RATING HARDWARE COMMENTS
SET
BIAE601
BIAE601
BIAE601
1-HR 1A
B/AE601
BIAE601
BIAE601
B/AE601
B/AE601
B/AE601
B/AE601
B/AE601
BIAE601
BIAE601
BIAE601
B/AE601
B/AE601
BIAE601
B/AE601
B/AE601
B/AE601
B/AE601
B/AE601
BiAE601
• TEMPERED AND FROSTED GLA.SS (TO MATCH EXISTING DOOR)
• FINISH; ANODIZED
• STANLEY AUTO DOOR: WALL SURfACE APPLIED
• COORDINATE WITH STAINLESS STEEL TOUCHLESS
ACTUATOR WITH ADJUSTABLE RANGE AND RELAY HOLD
TIME MOUNTED
ON WALL. PROV/DE ELECTRICAL PO\i\J'ER AS REQUIRED
DOOR TYPES
NOT TO SCALE
Drawing Title
JAMES J. PETERS
VETERANS AFFAIRS
MEDICAL CENTER
DOOR TYPES, SCHEDULE, DETAILS AND
PAR 11 TION TYPE
Approve<!: Project Director
VA
U.S. Department of Veterans Affairs
Phase
FRAME TYPES
1/4" = 1'-0"
100% BID DOCUMENTS
Project Title
MODIFY SCI
Location JAMES J. PETERS VA MEDICAL CENTER
130 W KINGSBRIDGE ROAD, BRONX, NY 10468
Issue Date 03-24-2025
Checked
BVG
Drawn ws
Project Number 526-21-120
Building Number
Drawing Number
AE601
A
B
C
D
A I
C
D
E
F
SCHEDULED FAUCET AND
CONTROLS, REFER TO
PLUMBING DRAWINGS --.._
SCHEDULED SOLID SURFACE
(SS-1) COUNTERTOP AND
SOLID SURFACE
I 2
LINE OF TOILET SHOWN AS
REFERENCE FOR PLACEMENT OF
RECESSED TOILET TISSUE SINGLE
ROLL HOLDER -------�
I
BACKSPLASH/SIDESPLASH 1(7\
TO MATCH - - --- --s
=::;o,..___,,,,,,,,�--,----,--- f--
LJ
-, ----=--=t----'t--=c---=n STAINLESS STEEL GRAB BAR " i\ ·,,,� _e lJi, " t,'r,1 !itf' itZ@: _, MOUNTED TO FRONT SKIRT PANEL ,…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .