This document provides the electrical drawings and specifications for the Marquette Armory Boiler Replacement project in Marquette, Michigan, which is being undertaken by the Michigan Department of Military and Veterans Affairs. The drawings detail the demolition and new installation of electrical infrastructure, including power distribution panels, lighting, and HVAC equipment. Key details include the project scope, equipment schedules, and electrical system one-line diagrams.

The project is located in Alger County and Menominee City, Michigan. Bids for this state and local contract opportunity are due by 2:00 PM on the bid deadline, with details on electronic bid submission provided. COVID-19 precautions may be in effect, requiring bidders to wear masks when attending meetings. The project term is not specified in the documentation provided.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CABLE TV, TELEPHONE,

DATA OR DUPLEX RECEPT

OUTLET (UNLESS NOTED)

TOP OF

COUNTER

BASEBOARD RADIATOR

FIRE ALARM

HORN/SPEAKER/STROBE

SWITCHES,

THERMOSTAT, WALL

OCCUPANCY SENSOR,

FIRE ALARM PULL

STATION

FLOOR

ELECTRIC WATER COOLER

CEILING

CL

7'

4'

6" M

IN

ELECTRICAL OUTLET

6"

6"

CL

/4

RECOMMENDATIONS

PER MANUFACTURERS

TYPICAL 3⌀ 4-WIRE

DRY-TYPE UTILITY

TRANSFORMER

T-X

TYPICAL 3⌀ 4-WIRE

DRY-TYPE TRANSFORMER

SERVICE FROM SERVICE PANEL

T-X

BRANCH PANEL

CONNECTIONS BY

UTILITY

SUPPLY-SIDE

BONDING JUMPER

SERVICE

PANEL

G

NEU. NEU.

G

BRANCH PANEL

GROUNDED CONDUCTOR

GROUNDING ELECTRODE

CONDUCTOR

GROUNDING ELECTRODE

REFER TO NOTE 2

EQUIPMENT GROUNDING

CONDUCTOR

MAIN BUILDING JUMPER

GRADE

GROUNDED CONDUCTOR SYSTEM BONDING

JUMPER

SUPPLY-SIDE

BONDING

JUMPER

SEPARATELY DERIVED SYSTEM

G

NEU.

1. SIZE GROUNDING/BONDING CONDUCTORS PER NEC ARTICLE 250

2. GROUNDING ELECTRODE SYSTEM AS PER NEC ARTICLE 250 SECTION III.

NOTES

1. ALL ELECTRICAL INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE CURRENT NATIONAL ELECTRICAL CODE AND ANY STATE/LOCAL AMENDMENTS.

2. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACQUISITION OF AN ELECTRICAL PERMIT AND SCHEDULING OF THE NECESSARY

INSPECTIONS. UPON COMPLETION OF THE WORK THE ELECTRICAL CONTRACTOR SHALL PROVIDE THE OWNER EVIDENCE OF INSPECTION APPROVAL.

3. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION REQUIRED WITH THE ELECTRIC UTILITY SERVING THE FACILITY. UTILITY

COSTS SHALL BE PAID SEPARATELY BY THE OWNER.

GENERAL NOTES - ELECTRICAL

SURFACE / CEILING MOUNT

EMERGENCY SURFACE / CEILING

MOUNT

PENDANT / CHAIN MOUNT

EMERGENCY PENDANT / CHAIN

MOUNT

RECESSED MOUNT

EMERGENCY RECESSED MOUNT

COMBINATION FAN / LIGHT

TRACK STRIP

WALL MOUNT

EMERGENCY WALL MOUNT

EXTERIOR POLE MOUNT

EXTERIOR POST MOUNT

EMERGENCY WALL PACK

EXIT SIGN

CEILING FAN

DISCONNECT SWITCH

FUSED DISCONNECT SWITCH

COMBINATION MOTOR STARTER

WITH DISCONNECT SWITCH

MOTOR STARTER

ELECTRICAL METER

DISTRIBUTION PANEL

ELECTRICAL POWER PANEL

SURFACE MOUNT

ELECTRICAL POWER PANEL

FLUSH MOUNT

LIGHITNG CONTROL PANEL

RELAY

ELECTRICAL TRANSFORMER

ELECTRICAL PULL BOX

JUNCTION BOX

SINGLE PHASE MOTOR

THREE PHASE MOTOR

VARIABLE FREQUENCY DRIVE

X = NUMBER AND TYPE OF PORTS

C COAXIAL PORT

D DATA PORT

H HDMI PORT

P PHONE PORT

W WIRELESS ACCESS POINT

X

X H Z

SENSORS

J J

PC

IC

PS

K

CR

DL

M

R

A

CO

HD

F F

F F

T

PB

1. MINIMUM SIZE OF RIGID CONDUIT SHALL BE 3/4".

2. MINIMUM SIZE OF FLEX CONDUIT SHALL BE 1/2".

3. MINIMUM SIZE WALL BOX IN CMU SHALL BE

4"X4".

4. MINIMUM SIZE OF UNDERGROUND CONDUIT

SHALL BE 1 1/4"

J

(WALL) (CEILING)

NURSE

N

N

FACP

FAA

FS

TS

PS

DH

C

P

(LIGHT)(NO LIGHT)

CARD READER

MAGNETIC SWITCH (DOOR CONTACT)

ELECTRONIC DOOR LOCK

MOTORIZED DOOR OPERATOR

ELECTRIC STRIKE

KEYPAD ENTRY DEVICE

ENTRANCE CALL SYSTEM

SECURITY CAMERA

PANIC ALARM SPEAKER/STROBE

ES

DP##

PP##

PP##

(WALL)

(CLG)

(FLR)

B

M

WG

HSS

OUTDOOR BELL / CHIME

SMOKE DETECTOR

SMOKE DETECTOR WITH AUDIBLE BASE

SMOKE/CARBON MONOXIDE DETECTOR

DUCT SMOKE DETECTOR

HEAT DETECTOR

FIRE ALARM HORN/STROBE

FIRE ALARM STROBE

FIRE ALARM SPEAKER

FIRE ALARM SPEAKER/STROBE

FIRE ALARM PULL STATION

ELECTROMAGNETIC DOOR HOLD OPEN

END OF LINE RESISTOR

FIRE ALARM FLOW SWITCH

FIRE ALARM PRESSURE SWITCH

FIRE ALARM TAMPER SWITCH

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

HOOD SUPPRESSION SYSTEM FIRE ALARM

CONTACT

ELR

I/C

DC

DO

SWITCHES: X = DESIGNATION BELOW

H = HUB CONTROLLER

Z = LIGHTING ZONE

PUSH BUTTON

EMERGENCY STOP BUTTON

PHOTOCELL

CEILING MOUNTED PULL SWITCH

WIRELESS NETWORK LIGHTING CONTROLLER

(HUB) H# = CONTROLLER INDICATOR

LIGHTING CONTROL SCHEME NUMBER

SINGLE POLE

2 TWO POLE

3 THREE WAY

4 FOUR WAY

DM DIMMER

F FAN

K KEY OPERATED

LV LOW VOLTAGE

M MOTION DETECTION

O OCCUPANCY SENSOR

P PILOT LIGHT

T TIMER

F F

S S

X

X X

(FURN)

SPEAKER

INTERCOM CALL BOX

BELL

MICROPHONE JACK

POWER SUPPLY

REQUIRES WIRE GUARD

NURSE CALL MAIN PANEL

NURSE CALL PULL STATION

NURSE CALL LIGHT

CLOCK

SIMPLEX RECEPTACLE

DUPLEX GROUNDED RECEPTACLE

208/240/480V, 1ϕ STRAIGHT BLADE RECEPTACLE

QUADRUPLEX RECEPTACLE

DUPLEX RECEPTACLE ON EMERGENCY POWER

FLOOR BOX

CEILING BOX

SPECIALTY RECEPTACLE

CTR MOUNTED ABOVE COUNTER

G GROUND FAULT CIRCUIT INTERRUPTER

GC GFCI - MOUNTED ABOVE COUNTER

U DUAL USB PORTS

UC DUAL USB PORTS ABOVE COUNTER

WP WEATHERPROOF RECEPT & COVER, GFI

H##

D DAYLIGHT

M MOTION DETECTION

O OCCUPANCY

V VACANCY

H = HUB CONTROLLER

Z = LIGHTING ZONE

XS X

H Z

S X H Z

LP##

(CEILING) (WALL)

(CEILING) (WALL)

(CEILING)

(WALL)

(WALL)(CLG)

(CLG) (WALL) (FLR)

ELECTRICAL SYMBOLS LEGEND

VFD

XX-X EQUIPMENT INDICATOR

INDICATES EXISTING

e LF-1

H Z

LIGHT FIXTURE INDICATOR

HUB CONTROLLER

LIGHTING ZONE

e

RACEWAY NOTES

WIRES

OTHER SYMBOLS

TELEPHONE/COMMUNICATIONS

FIRE ALARM SYSTEMRECEPTACLE OUTLETS

SECURITY

POWER DISTRIBUTION

LIGHT FIXTURES

SWITCHES

(360 VIEW)

P P

SX

(W/ LIGHTS)

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

P L

U R

I B

U

E S

U N

U M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I

S P

E N

I N

S U

L A

M A

M

OE

N A

M

ARCHITECTS ENGINEERS PLANNERS

OHM-ADVISORS.COM

R

424 Hancock Street Hancock, MI 49930

PH 906.482.0535 | F 906.482.6453

F

IL

E P

A T

H

S H

E E

T

ID

E N

T

IF

IC

A

T

IO

N N o.

IS

S U

E D

F O

R D

A T

E

OHM PROJECT No.

P R

E

LI

M

IN

A R

Y

C O

N S

T R

U C

T

IO

N

F

IN

A L

R E

C O

R D

D T

M B

F

IL

E N

U M

B E

R

COPYRIGHT 2022 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

A P

P R

O V

E D

A C

C O

U N

T

IN

G T

E M

P

B

IM

-2

2-

M ar qu et te

A rm or y

B oi le r

R ep la ce m en t/7

0_

F P

M E

_M ar qu et te A rm or y_ B oi le rR ep la ce m en t_

_C

E N

.r vt

6/

/2

9:

:0

A

M

C he ck er

A pp ro ve r

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

V

E T

E R

A N

S A

F F

A

IR

S

M ar qu et te A rm or y R ep la ce B oi le r E

-0

7136-22-0060

1/

6.

JB

B

E

LE

C T

R

IC

A L

N O

T E

S A

N D

S Y

M B

O

LS

D es ig ne r

/0 6/ xx xx

/x x/ xx xx xx

/x x/ xx

/0 6/

R

E V

IE

W

N.T.S

TYPICAL MOUNTING HEIGHTS

ELEC. ABBR.

_SPECIAL

Φ PHASE

A

A AMPERE

AFF ABOVE FINISHED FLOOR

C

C CONDUIT

CAT CATALOGUE

CB CIRCUIT BREAKER

CMU CONCRETE MASONRY UNIT

CO. COMPANY

CUH CABINET UNIT HEATER

E

EC ELECTRICAL CONTRACTOR

EF EXHAUST FAN

EWC ELECTRIC WATER COOLER

F

FA FIRE ALARM

G

G GROUND FAULT CIRCUIT

INTERRUPTER

GND EQUIPMENT GROUND

H

HID HIGH INTENSITY DISCHARGE

HPS HIGH PRESSURE SODIUM

HVAC HEATING VENTILATING & AIR

CONDITIONING

K

K KEY OPERATED DEVICE

KVA KILOVOLT-AMPERES

KW KILOWATTS

L

LED LIGHT EMITTING DIODE

M

MCB MAIN CIRCUIT BREAKER

MDP MAIN DISTRIBUTION PANEL

MH METAL HALIDE

MISC MISCELLANEOUS

MLO MAIN LUG ONLY

MTD MOUNTED

N

NEU NEUTRAL

No. NUMBER

P

PL PILOT

R

RECEPT RECEPTACLE

T

TEL TELEPHONE

TV TELEVISION

TYP TYPICAL

U

UGE UNDERGROUND ELECTRIC

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

V

V VOLT

VA VOLT-AMPERES

W

W WIRE

WNC WIRELESS NETWORK CONTROLLER

WP WEATHERPROOF

X

XFMR TRANSFORMER

N.T.S

GROUNDING BONDING DIAGRAM

DN

2D

J

LPB

LP-C

LOCATED ABOVE MEZZANINE

UNIT HEATERS STARTER

AND HOA SWITCH

SWITCH FOR FAN AND LIGHTS

SWITCH FOR FAN AND LIGHTS

4 4 4 4

1. DRAWINGS SHOW MAJOR DEMOLITION ONLY; THE CONTRACTOR SHALL PROVIDE ALL DEMOLITION

FOR THE COMPLETION OF THE WORK WHETHER EXPLICITLY SHOWN OR NOT.

2. THE OWNER RESERVES THE RIGHT TO KEEP ANY REMOVED EQUIPMENT OR MATERIALS. ALL

DEMOLITION DEBRIS TO BE REMOVED FROM THE SITE AND DISPOSED OF IN AN APPROVED LANDFILL.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY TEMPORARY EXTERIOR OPENINGS MADE FROM

DEMOLITION WORK TO ENSURE THEY ARE WEATHER TIGHT AT THE END OF EACH DAY.

4. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING WHERE CONDUITS AND

JUNCTION BOXES ARE REMOVED UNLESS OTHERWISE NOTED.

5. ANY JUNCTION BOXES REMAINING IN PLACE THAT HAVE HAD DEVICES REMOVED ARE TO RECEIVE

BLANK COVER PLATES MATCHING PROJECT REQUIREMENTS.

6. CONDUITS AND CONDUCTORS ABANDONED AS PART OF THE WORK SHALL BE DEMOLISHED WHERE NOT BURIED IN WALLS OR UNDERGROUND. CAP OR PLUG ANY ABANDONED CONDUITS THAT REMAIN.

7. WHERE DEVICES ARE REMOVED FROM THE MIDDLE OF A CIRCUIT, THE CONTRACTOR SHALL BE RESPONSIBLE TO RE-ROUTE THE CIRCUIT TO MAINTAIN CIRCUIT INTEGRITY TO REMAINING DEVICES.

8. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES FOUND IN EXISTING CONDITIONS.

9. CONTRACTOR TO COORDINATE WITH THE OWNER OR ENGINEER A MINIMUM OF 24 HOURS IN

ADVANCE OF SHUTTING OFF OR DISCONNECTING ANY UTILITIES. CONTRACTOR TO ENSURE ALL

EXISTING SYSTEMS TO REMAIN ARE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT

UNLESS OTHERWISE DIRECTED BY THE ENGINEER/OWNER.

10. CONTRACTOR TO TAKE ALL PRECAUTIONS NECESSARY TO PROTECT ITEMS NOT INTENDED TO BE

DEMOLISHED AND TO RESTORE TO EXISTING CONDITIONS ANY ITEMS DAMAGED THAT WERE NOT

INTENDED TO BE DEMOLISHED.

GENERAL NOTES - ELECTRICAL DEMOLITION

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

P L

U R

I B

U

E S

U N

U M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I

S P

E N

I N

S U

L A

M A

M

OE

N A

M

ARCHITECTS ENGINEERS PLANNERS

OHM-ADVISORS.COM

R

424 Hancock Street Hancock, MI 49930

PH 906.482.0535 | F 906.482.6453

F

IL

E P

A T

H

S H

E E

T

ID

E N

T

IF

IC

A

T

IO

N N o.

IS

S U

E D

F O

R D

A T

E

OHM PROJECT No.

P R

E

LI

M

IN

A R

Y

C O

N S

T R

U C

T

IO

N

F

IN

A L

R E

C O

R D

D T

M B

F

IL

E N

U M

B E

R

COPYRIGHT 2022 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

A P

P R

O V

E D

A C

C O

U N

T

IN

G T

E M

P

B

IM

-2

2-

M ar qu et te

A rm or y

B oi le r

R ep la ce m en t/7

0_

F P

M E

_M ar qu et te A rm or y_ B oi le rR ep la ce m en t_

_C

E N

.r vt

6/

/2

9:

:0

A

M

C he ck er

A pp ro ve r

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

V

E T

E R

A N

S A

F F

A

IR

S

M ar qu et te A rm or y R ep la ce B oi le r E

D P

7136-22-0060

1/

6.

JB

B

1S T

F

LO

O R

E

LE

C T

R

IC

A L

D E

M O

LI

T

IO

N

P

LA

N

D es ig ne r

/0 6/ xx xx

/x x/ xx xx xx

/x x/ xx

/0 6/

R

E V

IE

W

3/32" = 1'-0"1

1ST FLOOR ELECTRICAL DEMOLITION PLAN

SHEET KEYNOTES - ELEC. DEMOLITION

1 REMOVE CONNECTION TO WATER HEATER. REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE.

2 REMOVE CONNECTION TO MECHANICAL EQUIPMENT. REMOVE DISCONNECTS, CONDUIT AND CONDUCTORS

BACK TO SOURCE.

3 REMOVE CONNECTION TO UNIT HEATER. REMOVE DISCONNECT, CONDUIT AND CONDUCTORS BACK TO

SOURCE.

4 REMOVE LIGHT FIXTURE. REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE OR NEAREST FIXTURE TO

REMAIN

5 REMOVE LIGHT SWITCH. REMOVE CONDUCTORS BACK TO SOURCE.

6 REMOVE MOTOR STARTER/HOA SWITCH. REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE.

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

P L

U R

I B

U

E S

U N

U M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I

S P

E N

I N

S U

L A

M A

M

OE

N A

M

ARCHITECTS ENGINEERS PLANNERS

OHM-ADVISORS.COM

R

424 Hancock Street Hancock, MI 49930

PH 906.482.0535 | F 906.482.6453

F

IL

E P

A T

H

S H

E E

T

ID

E N

T

IF

IC

A

T

IO

N N o.

IS

S U

E D

F O

R D

A T

E

OHM PROJECT No.

P R

E

LI

M

IN

A R

Y

C O

N S

T R

U C

T

IO

N

F

IN

A L

R E

C O

R D

D T

M B

F

IL

E N

U M

B E

R

COPYRIGHT 2022 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

A P

P R

O V

E D

A C

C O

U N

T

IN

G T

E M

P

B

IM

-2

2-

M ar qu et te

A rm or y

B oi le r

R ep la ce m en t/7

0_

F P

M E

_M ar qu et te A rm or y_ B oi le rR ep la ce m en t_

_C

E N

.r vt

6/

/2

9:

:0

A

M

C he ck er

A pp ro ve r

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

V

E T

E R

A N

S A

F F

A

IR

S

M ar qu et te A rm or y R ep la ce B oi le r E

D

7136-22-0060

1/

6.

JB

B

E

LE

C T

R

IC

A L

D E

M O

LI

T

IO

N

S C

H E

D U

LE

S

D es ig ne r

/0 6/ xx xx

/x x/ xx xx xx

/x x/ xx

/0 6/

R

E V

IE

W

CONNECTED LOAD: (kVA) 0.00 0.00

UNKNOWN -- 1 20 39 0.00 0.00 40

RCAS,PC2-SUPPLY ROOM -- 1 20 37 0.00 0.00 38

20 2 -- AIR CONDITIONER-RM 125-126

TIMER SWITCH -- 1 20 35 0.00 0.00 36 20 1 -- BOILER ROOM

EXHAUST-SHOWER TOILET -- 1 20 33 0.00 0.00 34 20 1 -- AIR COMPRESSOR

SPARE -- 1 20 31 0.00 0.00 32 20 1 -- EXHAUST-E.M. SHOWER RM

LIGHTS-CLASSROOM(WEST)(... -- 1 20 29 0.00 0.00 30 20 1 -- LIGHTS-CLASSROOM (EAST)...

LIGHTS-BOILER RM -- 1 20 27 0.00 0.00 28 20 1 -- LIGHTS-DAY ROOM

CONDENSATE PUMPS -- 1 20 25 0.00 0.00 26 20 1 -- HEATER UNIT VENTS-RM127

RCAS,PC3-ORDERLY RM -- 1 20 23 0.00 0.00 24 20 1 -- RECEPT-LIEUT OFFICE

DRINKING FILTER-LOBBY -- 1 20 21 0.00 0.00 22 20 1 -- RECEPT LOBBY

AIR CONDITIONER-RM 132 -- 1 20 19 0.00 0.00 20 20 1 -- OIL CIRCULATOR

LIGHTS-E.M. LOCKER RM UNI... -- 1 20 17 0.00 0.00 18 20 1 -- UNIT HEATER-STORAGE RM

LIGHTS-E.M. SHOWER RM -- 1 20 15 0.00 0.00 16 20 1 -- LIGHTS-E.M. LOCKER RM

LIGHTS-LIEUT OFFICE -- 1 20 13 0.00 0.00 14 20 1 -- LIGHTS-LIET LOCKER...

LIGHTS-PUBLIC... -- 1 20 11 0.00 0.00 12 20 1 -- LIGHTS-ORDERLY RM,OFFICE

LIGHTS-ENTRANCE -- 1 20 9 0.00 0.00 10 20 1 -- LOBBY LIGHTS

RCAS-TRAINING OFFICE,PC4 -- 1 20 7 0.00 0.00 8 20 1 -- LIGHTS-UNIT STORAGE

RECEPT-DAYROOM AND... -- 1 20 5 0.00 0.00 6 20 1 -- LIGHTS-VAULT,SIGNAL UTILIT...

RECEPT-WOMANS BATHROOM -- 1 20 3 0.00 0.00 4 20 1 -- RECEPT-BOILER &...

RECEPT-UNIT STORAGE &... -- 1 20 1 0.00 0.00 2 20 1 -- RECEPT-E.M. STORAGE &...

IDENTIFICATION WIRE POLE AMP CKT

A B A B

CKT AMP POLE WIRE IDENTIFICATION

BOLD ITALIC TEXT DENOTES DEMOLITION

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 3 MCB RATING: N/A

SUPPLY FROM: PHASES: 1 MAINS TYPE: MLO

LOCATION: HEATER RM 124 VOLTS: 120/208 Single SCCR RATING:

BRANCH PANEL: LP-C_DEMO

CONNECTED LOAD: (kVA) 0.00 0.00

TIRE CHANGER -- 1 20 33 0.00 0.00 34 20 1 -- DISPATCH OFFICE LIGHTS

TIRE CHANGER -- 1 20 31 0.00 0.00 32 20 1 -- GARAGE CEILING FANS

SIGNAL ROOM -- 1 20 29 0.00 0.00 30 20 1 -- RECEPT BELOW PANEL

ASSEMBLY HALL EXHAUST -- 1 20 27 0.00 0.00 28 20 1 -- SIGNAL ROOM

UNIT HEATERS SOUTH -- 1 20 25 0.00 0.00 26 20 1 -- FIRINGLINE STRWL LIGHTS

UNIT HEATERS WEST -- 1 20 23 0.00 0.00 24 20 1 -- UNIT HEATERS NORTH

MAINT ROOM HEATER -- 1 20 21 0.00 0.00 22 20 1 -- UNIT HEATERS EAST

AT&T RECEPT -- 1 20 19 0.00 0.00 20 20 1 -- MAINT SHIP A/C

RIFLE RANGE SUMP PUMP -- 1 20 17 0.00 0.00 18 20 1 -- MAINT SHIP A/C

RIFLE RANGE LIGHTS EAST -- 1 20 15 0.00 0.00 16 20 1 -- RIFLE RANGE RECEPT

CLASSROOM & OFFICE LIGHTS -- 1 20 13 0.00 0.00 14 20 1 -- RIFLE RANGE LIGHTS WEST

GARAGE LIGHTS WEST... -- 1 20 11 0.00 0.00 12 20 1 -- UNIT STORAGE LIGHTS

GARAGE LIGHTS WEST -- 1 20 9 0.00 0.00 10 20 1 -- MAINT ROOM LIGHTS

GARAGE LIGHTS SOUTHEAST -- 1 20 7 0.00 0.00 8 20 1 -- OUTSIDE LIGHTS

GARAGE LIGHTS NORTHEAST -- 1 20 5 0.00 0.00 6 20 1 -- MAINT ROOM RECEPT

STOREROOM RECEPT -- 1 20 3 0.00 0.00 4 20 1 -- STOREROOM LIGHTS

GARAGE RECEPT WEST -- 1 20 1 0.00 0.00 2 20 1 -- GARAGE RECEPT EAST

IDENTIFICATION WIRE POLE AMP CKT

A B A B

CKT AMP POLE WIRE IDENTIFICATION

BOLD ITALIC TEXT DENOTES DEMOLITION

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 3 MCB RATING: N/A

SUPPLY FROM: PHASES: 1 MAINS TYPE: MLO

LOCATION: FOOD STORAGE ARE... VOLTS: 120/208 Single SCCR RATING:

BRANCH PANEL: LPA_DEMO

CONNECTED LOAD: (kVA) 0.00 0.00 0.00

27 28

25 26

23 24

21 0.00 0.00 22

19 0.00 0.00 20OIL HEATER -- 3 50

17 0.00 0.00 18

50 3 -- NEW BUILDING/FURNACE

15 0.00 0.00 16

13 0.00 0.00 14PUMP P2 -- 3 50

11 0.00 0.00 12

50 3 -- PUMP P1

9 0.00 0.00 10

7 0.00 0.00 8BOILER -- 3 50

5 0.00 0.00 6

50 3 -- BAR SUBPANEL

3 0.00 0.00 4

UNKNOWN -- 2 50

1 0.00 0.00 2

100 2 -- UNKNOWN

IDENTIFICATION WIRE POLE AMP CKT

A kVA

B kVA

C kVA

A kVA

B kVA

C kVA

CKT AMP POLE WIRE IDENTIFICATION

BOLD ITALIC TEXT DENOTES DEMOLITION

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 4 MCB RATING: N/A

SUPPLY FROM: PHASES: 3 MAINS TYPE: MLO

LOCATION: HEATER RM 124 VOLTS: 120/208 Wye SCCR RATING:

EXISTING BRANCH PANEL: PP1_DEMO

DM

S O

S O

S V S V

DM

EXISTING CKT

EXISTING CKT

EXISTING CKT

OCCUPANCY SENSOR TO

CONTROL BATHROOM FAN

PL1PL1E

PL1

PL1E

PL1

LT1 DW

LT1EDW

LT1 DW

LT1 DW

LT1EDWLT1 DW

LT1 LT1

LT1

LT1

LT1

LT1

LT1

LT1

LT1

LT1 LT1

LT1 LT1

LT1

LT1

BREAK RM

E.M. TOILET

UTILITY RM

DRYING

SHOWER

SIGNAL RM

STRONG RM

ASSEMBLY HALL

STAIR

UNIT STORAGE

LOBBY.

FEMALE DRYING ROOM

121B

FEMALE LOUNGE

FEMALE LATRINE

HEATER RM

LIBRARY & DAY RM

CLASS RM

VESTIBULE

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

P L

U R

I B

U

E S

U N

U M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I

S P

E N

I N

S U

L A

M A

M

OE

N A

M

ARCHITECTS ENGINEERS PLANNERS

OHM-ADVISORS.COM

R

424 Hancock Street Hancock, MI 49930

PH 906.482.0535 | F 906.482.6453

F

IL

E P

A T

H

S H

E E

T

ID

E N

T

IF

IC

A

T

IO

N N o.

IS

S U

E D

F O

R D

A T

E

OHM PROJECT No.

P R

E

LI

M

IN

A R

Y

C O

N S

T R

U C

T

IO

N

F

IN

A L

R E

C O

R D

D T

M B

F

IL

E N

U M

B E

R

COPYRIGHT 2022 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

A P

P R

O V

E D

A C

C O

U N

T

IN

G T

E M

P

B

IM

-2

2-

M ar qu et te

A rm or y

B oi le r

R ep la ce m en t/7

0_

F P

M E

_M ar qu et te A rm or y_ B oi le rR ep la ce m en t_

_C

E N

.r vt

6/

/2

9:

:0

A

M

C he ck er

A pp ro ve r

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

V

E T

E R

A N

S A

F F

A

IR

S

M ar qu et te A rm or y R ep la ce B oi le r E

L1

7136-22-0060

1/

6.

JB

B

1S T

F

LO

O R

L

IG

H T

IN

G

P

LA

N

D es ig ne r

/0 6/ xx xx

/x x/ xx xx xx

/x x/ xx

/0 6/

R

E V

IE

W

3/32" = 1'-0"1

1ST FLOOR LIGHTING PLAN

FD FD

FD

LP-C

LPB

FS (RIGHT)

FS (LEFT)

LP-ADP

CONTROL SWITCHES FOR CONTACTORS

EF LOCATED ON ROOF

CT CAB & CONNECTION BOX

MAIN SWITCH

EXIT LIGHT PANEL

UV-3

UH-10

UH-11

UH-9

UH-1

UH-4

UH-5

UH-2 UH-3

UH-6

B-1 B-2

P-4

P-5

P-6

P-3

P-1

P-2

PP1

UH-8

BOILER E-STOP SEE

DETAIL 2 SHEET E-501

BOILER E-STOP SEE

DETAIL 2 SHEET E-501

EXHAUST FAN SWITCH

WITH TOILET LIGHTING

OCCUPANCY SENSOR

PP1 - 5,7,9

LP-C - 18

BREAK RM

VEHICLE STORAGE

107A

FOOD SERVICE AREA

106A

UNIT STORAGE

UNIT STORAGE

UNIT STORAGE

STAIR

E.M. TOILET

PASSAGE

DRYING

UTILITY RM

SHOWER

SIGNAL RM

STRONG RM

UNIT STORAGE

FEMALE DRYING ROOM

121B

FEMALE LOUNGE

FEMALE LATRINE

ASSEMBLY HALL

LOBBY.

ORDERLY RM

OFFICE

LIEUT OFFICE

TOILET

136 LOCKER RM

TRAINING

VESTIBULE

LIBRARY & DAY RM

HEATER RM

CLASS RM

LP-A - 22

LP-A - 23

FS (LEFT) - 54,56

LP-C - 25

FS (LEFT) - 58

FS (LEFT) - 59

SUMP PUMP

UH-7

LP-A - 22

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

P L

U R

I B

U

E S

U N

U M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I

S P

E N

I N

S U

L A

M A

M

OE

N A

M

ARCHITECTS ENGINEERS PLANNERS

OHM-ADVISORS.COM

R

424 Hancock Street Hancock, MI 49930

PH 906.482.0535 | F 906.482.6453

F

IL

E P

A T

H

S H

E E

T

ID

E N

T

IF

IC

A

T

IO

N N o.

IS

S U

E D

F O

R D

A T

E

OHM PROJECT No.

P R

E

LI

M

IN

A R

Y

C O

N S

T R

U C

T

IO

N

F

IN

A L

R E

C O

R D

D T

M B

F

IL

E N

U M

B E

R

COPYRIGHT 2022 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

A P

P R

O V

E D

A C

C O

U N

T

IN

G T

E M

P

B

IM

-2

2-

M ar qu et te

A rm or y

B oi le r

R ep la ce m en t/7

0_

F P

M E

_M ar qu et te A rm or y_ B oi le rR ep la ce m en t_

_C

E N

.r vt

6/

/2

9:

:0

A

M

C he ck er

A pp ro ve r

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

V

E T

E R

A N

S A

F F

A

IR

S

M ar qu et te A rm or y R ep la ce B oi le r E

P

7136-22-0060

1/

6.

JB

B

P O

W E

R P

LA

N

D es ig ne r

/0 6/ xx xx

/x x/ xx xx xx

/x x/ xx

/0 6/

R

E V

IE

W

3/32" = 1'-0"1

1ST FLOOR POWER PLAN

3/32" = 1'-0"2

BASEMENT POWER PLAN

WP

CU-1

FS (LEFT) - 55,57

LP-A - 24

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

P L

U R

I B

U

E S

U N

U M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I

S P

E N

I N

S U

L A

M A

M

OE

N A

M

ARCHITECTS ENGINEERS PLANNERS

OHM-ADVISORS.COM

R

424 Hancock Street Hancock, MI 49930

PH 906.482.0535 | F 906.482.6453

F

IL

E P

A T

H

S H

E E

T

ID

E N

T

IF

IC

A

T

IO

N N o.

IS

S U

E D

F O

R D

A T

E

OHM PROJECT No.

P R

E

LI

M

IN

A R

Y

C O

N S

T R

U C

T

IO

N

F

IN

A L

R E

C O

R D

D T

M B

F

IL

E N

U M

B E

R

COPYRIGHT 2022 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

A P

P R

O V

E D

A C

C O

U N

T

IN

G T

E M

P

B

IM

-2

2-

M ar qu et te

A rm or y

B oi le r

R ep la ce m en t/7

0_

F P

M E

_M ar qu et te A rm or y_ B oi le rR ep la ce m en t_

_C

E N

.r vt

6/

/2

9:

:0

A

M

C he ck er

A pp ro ve r

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

V

E T

E R

A N

S A

F F

A

IR

S

M ar qu et te A rm or y R ep la ce B oi le r E

P

7136-22-0060

1/

6.

JB

B

R O

O F

P O

W E

R P

LA

N

D es ig ne r

/0 6/ xx xx

/x x/ xx xx xx

/x x/ xx

/0 6/

R

E V

IE

W

3/32" = 1'-0"1

ROOF POWER PLAN

DP1

PP1

200A

28CKT

MLO

POLE MOUNT

TRANSFORMER

BY UTILITY

225A/125 3P

100A/70 2P

AIR

COMPRESSOR

50A 2P

1 2 3 4 5

M

METER SOCKET

AND C.T CABINET

600A FUSED DISCONNECT

225A/125 2P

LPB

200A

34CKT

MLO

225A/125 2P

LPA

200A

34CKT

MLO

LPC

200A

42CKT

MLO

EXHUAST FAN

50A 3P

XXA

3P

XXA

3P

ELECTRICAL CIRCUIT

ELECTRICAL CIRCUIT

R

ELECTRICAL CIRCUIT

N

BOILER CONTROL RELAY

LOCKABLE

DISCONNECT

MAINTAINED

PUSH BUTTON

N

N

B-1 BOILER TERMINAL

B-2 BOILER TERMINAL

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

P L

U R

I B

U

E S

U N

U M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I

S P

E N

I N

S U

L A

M A

M

OE

N A

M

ARCHITECTS ENGINEERS PLANNERS

OHM-ADVISORS.COM

R

424 Hancock Street Hancock, MI 49930

PH 906.482.0535 | F 906.482.6453

F

IL

E P

A T

H

S H

E E

T

ID

E N

T

IF

IC

A

T

IO

N N o.

IS

S U

E D

F O

R D

A T

E

OHM PROJECT No.

P R

E

LI

M

IN

A R

Y

C O

N S

T R

U C

T

IO

N

F

IN

A L

R E

C O

R D

D T

M B

F

IL

E N

U M

B E

R

COPYRIGHT 2022 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

A P

P R

O V

E D

A C

C O

U N

T

IN

G T

E M

P

B

IM

-2

2-

M ar qu et te

A rm or y

B oi le r

R ep la ce m en t/7

0_

F P

M E

_M ar qu et te A rm or y_ B oi le rR ep la ce m en t_

_C

E N

.r vt

6/

/2

9:

:0

A

M

C he ck er

A pp ro ve r

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

V

E T

E R

A N

S A

F F

A

IR

S

M ar qu et te A rm or y R ep la ce B oi le r E

-5

7136-22-0060

1/

6.

JB

B

E

LE

C T

R

IC

A L

D E

T A

IL

S

D es ig ne r

/0 6/ xx xx

/x x/ xx xx xx

/x x/ xx

/0 6/

R

E V

IE

W

1/8" = 1'-0"1

ONE LINE DIAGRAM

12" = 1'-0"2

BOILER EMERGENCY SHUTOFF DETAIL

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T A

N D

B U

D G

E T

S T

A T

E O

F M

IC

H

IG

A

N

A D

A M

P L

A C

H R

A D

IR

E

C T

O R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

D E

S

IG

N A

N D

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

P L

U R

I B

U

E S

U N

U M

C I

R C

U M

S P

I C

E

S I

Q U

E R

E I

S P

E N

I N

S U

L A

M A

M

OE

N A

M

ARCHITECTS ENGINEERS PLANNERS

OHM-ADVISORS.COM

R

424 Hancock Street Hancock, MI 49930

PH 906.482.0535 | F 906.482.6453

F

IL

E P

A T

H

S H

E E

T

ID

E N

T

IF

IC

A

T

IO

N N o.

IS

S U

E D

F O

R D

A T

E

OHM PROJECT No.

P R

E

LI

M

IN

A R

Y

C O

N S

T R

U C

T

IO

N

F

IN

A L

R E

C O

R D

D T

M B

F

IL

E N

U M

B E

R

COPYRIGHT 2022 OHM ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF OHM AND THE SAME MAY NOT BE DUPLICATED, DISTRIBUTED, OR DISCLOSED WITHOUT PRIOR WRITTEN CONSENT OF OHM

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

A P

P R

O V

E D

A C

C O

U N

T

IN

G T

E M

P

B

IM

-2

2-

M ar qu et te

A rm or y

B oi le r

R ep la ce m en t/7

0_

F P

M E

_M ar qu et te A rm or y_ B oi le rR ep la ce m en t_

_C

E N

.r vt

6/

/2

9:

:0

A

M

C he ck er

A pp ro ve r

D E

P A

R T

M E

N T

O F

M

IL

IT

A

R Y

V

E T

E R

A N

S A

F F

A

IR

S

M ar qu et te A rm or y R ep la ce B oi le r E

-6

7136-22-0060

1/

6.

JB

B

E

LE

C T

R

IC

A L

S C

H E

D U

LE

S

D es ig ne r

/0 6/ xx xx

/x x/ xx xx xx

/x x/ xx

/0 6/

R

E V

IE

W

CONNECTED LOAD: (kVA) 0.00 0.00

UNKNOWN -- 1 20 39 0.00 0.00 40

RCAS,PC2-SUPPLY ROOM -- 1 20 37 0.00 0.00 38

20 2 -- AIR CONDITIONER-RM 125-126

TIMER SWITCH -- 1 20 35 0.00 0.00 36 20 1 -- BOILER ROOM

EXHAUST-SHOWER TOILET -- 1 20 33 0.00 0.00 34 20 1 -- AIR COMPRESSOR

SPARE -- 1 20 31 0.00 0.00 32 20 1 -- EXHAUST-E.M. SHOWER RM

LIGHTS-CLASSROOM(WEST)(... -- 1 20 29 0.00 0.00 30 20 1 -- LIGHTS-CLASSROOM (EAST)...

LIGHTS-BOILER RM -- 1 20 27 0.00 0.00 28 20 1 -- LIGHTS-DAY ROOM

BOILERS B-1 AND B-2 12 1 20 25 0.00 0.00 26 20 1 -- HEATER UNIT VENTS-RM127

RCAS,PC3-ORDERLY RM -- 1 20 23 0.00 0.00 24 20 1 -- RECEPT-LIEUT OFFICE

DRINKING FILTER-LOBBY -- 1 20 21 0.00 0.00 22 20 1 -- RECEPT LOBBY

AIR CONDITIONER-RM 132 -- 1 20 19 0.00 0.00 20 20 1 -- OIL CIRCULATOR

LIGHTS-E.M. LOCKER RM UNI... -- 1 20 17 0.00 0.00 18 20 1 12 UH-9, UH-10, UH-11

LIGHTS-E.M. SHOWER RM -- 1 20 15 0.00 0.00 16 20 1 -- LIGHTS-E.M. LOCKER RM

LIGHTS-LIEUT OFFICE -- 1 20 13 0.00 0.00 14 20 1 -- LIGHTS-LIET LOCKER...

LIGHTS-PUBLIC... -- 1 20 11 0.00 0.00 12 20 1 -- LIGHTS-ORDERLY RM,OFFICE

LIGHTS-ENTRANCE -- 1 20 9 0.00 0.00 10 20 1 -- LOBBY LIGHTS

RCAS-TRAINING... -- 1 20 7 0.00 0.00 8 20 1 -- LIGHTS-UNIT STORAGE

RECEPT-DAYROOM AND... -- 1 20 5 0.00 0.00 6 20 1 -- LIGHTS-VAULT,SIGNAL UTILIT...

RECEPT-WOMENS BATHROOM -- 1 20 3 0.00 0.00 4 20 1 -- RECEPT-BOILER &...

RECEPT-UNIT STORAGE &... -- 1 20 1 0.00 0.00 2 20 1 -- RECEPT-E.M. STORAGE &...

IDENTIFICATION WIRE POLE AMP CKT

A kVA

B kVA

A kVA

B kVA

CKT AMP POLE WIRE IDENTIFICATION

BOLD ITALIC INDICATES PROPOSED DEVICE

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 3 MCB RATING: N/A

SUPPLY FROM: PHASES: 1 MAINS TYPE: MLO

LOCATION: HEATER RM 124 VOLTS: 120/208 Single SCCR RATING:

EXISTING BRANCH PANEL: LP-C

CONNECTED LOAD: (kVA) 0.00 0.00

-- 1 20 31 0.00 0.00 32 20 1 --

ASSEMBLY HALL CONTACTOR -- 1 20 29 0.00 0.00 30 20 1 -- ASSEMBLY HALL CONTACTOR

ASSEMBLY HALL CONTACTOR -- 1 20 27 0.00 0.00 28 20 1 -- ASSEMBLY HALL CONTACTOR

SPARE -- 1 20 25 0.00 0.00 26 20 1 -- SPARE

UNIT VENT MOTORS -- 1 20 23 0.00 0.00 24 20 1 --

UNKNOWN -- 1 20 21 0.00 0.00 22 20 1 -- UNIT VENT MOTORS

RECEPT-EAST -- 1 20 19 0.00 0.00 20 20 1 -- UNKNOWN

UNKNOWN -- 1 20 17 0.00 0.00 18 20 1 -- UNKNOWN

UNKNOWN -- 1 20 15 0.00 0.00 16 20 1 -- UNKNOWN

LIGHTS-ASSEMBLY HALL -- 1 20 13 0.00 0.00 14 20 1 -- LIGHTS-ASSEMBLY HALL

LIGHTS-ASSEMBLY HALL -- 1 20 11 0.00 0.00 12 20 1 -- LIGHTS-ASSEMBLY HALL

LIGHTS-ASSEMBLY HALL -- 1 20 9 0.00 0.00 10 20 1 -- LIGHTS-ASSEMBLY HALL

LIGHTS-ASSEMBLY HALL -- 1 20 7 0.00 0.00 8 20 1 -- LIGHTS-ASSEMBLY HALL

LIGHTS-ASSEMBLY HALL -- 1 20 5 0.00 0.00 6 20 1 -- LIGHTS-ASSEMBLY HALL

LIGHTS-ASSEMBLY HALL -- 1 20 3 0.00 0.00 4 20 1 -- LIGHTS-ASSEMBLY HALL

LIGHTS-ASSEMBLY HALL -- 1 20 1 0.00 0.00 2 20 1 -- LIGHTS-ASSEMBLY HALL

IDENTIFICATION WIRE POLE AMP CKT

A kVA

B kVA

A kVA

B kVA

CKT AMP POLE WIRE IDENTIFICATION

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 3 MCB RATING: N/A

SUPPLY FROM: PHASES: 1 MAINS TYPE: MLO

LOCATION: ASSEMBLY HALL 100 VOLTS: 120/208 Single SCCR RATING:

EXISTING BRANCH PANEL: LPB

CONNECTED LOAD: (kVA) 3.60 2.90 0.70

#57 ICE MAKER -- 1 20 29 0.00 0.00 30

VEGETABLE RECEPT -- 1 20 27 0.00 0.00 28

20 2 --

SHUNT TRIP #49 STACKED

OVER RECEPT

25 0.00 0.00 26 20 1 -- DAIRY REFRIGERATOR

23 0.00 0.00 24 20 1 -- #67 FREEZER RECEPT#26 GARBAGE DISPOSAL -- 3 20

21 0.00 0.00 22 20 1 -- COOKING HOOD CONTROL...

19 0.00 0.00 20 20 1 -- COOKING HOOD LIGHTS

HOT FOOD PAN -- 2 20

17 0.00 0.00 18

#16 COLD FOOD PAN -- 1 20 15 0.00 0.00 16

20 2 --

SHUNT TRIP GAS RANGE

RECEPT

FOOD STORAGE RM EXHAUS... -- 1 20 13 0.00 0.00 14

11 0.00 0.00 12

9 0.00 0.00 10

20 3 --

ROOF COMBO EXHAUST FAN

MAKE UP AIR UNIT

COFFEE MAKER -- 3 45

7 0.00 0.00 8 20 1 -- WATER HEATER CIRC PUMPS

#3 MIXER DUPLEX RECEPT -- 1 20 5 0.00 0.00 6 20 1 -- DISHWASHER EXHAUST HOOD

LIGHTS-FOOD STORAGE -- 1 20 3 0.00 0.00 4 20 1 -- RECEPTS-FOOD STORAGE

LIGHTS-FOOD SERVICE -- 1 20 1 0.00 0.00 2 20 1 -- LIGHTS-SCULLERY AREA

IDENTIFICATION WIRE POLE AMP CKT

A kVA

B kVA

C kVA

A kVA

B kVA

C kVA

CKT AMP POLE WIRE IDENTIFICATION

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 4 MCB RATING: 250 A

SUPPLY FROM: PHASES: 3 MAINS TYPE: MCB

LOCATION: FOOD STORAGE ARE... VOLTS: 120/208 Wye SCCR RATING:

EXISTING BRANCH PANEL: FS (RIGHT)

CONNECTED LOAD: (kVA) 3.60 2.90 0.70

PUMP P-5 12 1 20 59 0.00 60

57 2.90 0.00 58 20 1 12 PUMP P-4

CU-1 (ROOF) 8 2 40

55 2.90 0.70 56

BASEMENT 4 PLUG BOX -- 1 20 53 0.00 0.70 54

20 2 12 UV-3

DATA ROUTER CLOSET... -- 1 20 51 0.00 0.00 52

OFFICE RECEPTS -- 1 20 49 0.00 0.00 50

20 2 -- SERVER ROOM A/C

ROOFTOP AHU 120V RECEPT -- 1 20 47 0.00 0.00 48

GARAGE WORKBENCH... -- 1 20 45 0.00 0.00 46

GARAGE WORKBENCH... -- 1 20 43 0.00 0.00 44

35 3 -- #30 DISHWASHER

FOOD PREP & DVULLRTY... -- 1 20 41 0.00 0.00 42

FOOD PREP RECEPTS -- 1 20 39 0.00 0.00 40

37 0.00 0.00 38

35 3 -- #36 BOOSTER HEATER

35 0.00 0.00 36DISHWASHER -- 3 60

33 0.00 0.00 34

OFFICE REPECTS -- 1 20 31 0.00 0.00 32

20 3 -- #54 GARBAGE DISPOSAL

IDENTIFICATION WIRE POLE AMP CKT

A kVA

B kVA

C kVA

A kVA

B kVA

C kVA

CKT AMP POLE WIRE IDENTIFICATION

BOLD ITALIC INDICATES PROPOSED DEVICE

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 4 MCB RATING: 225 A

SUPPLY FROM: FS (RIGHT) PHASES: 3 MAINS TYPE: MCB

LOCATION: FOOD STORAGE ARE... VOLTS: 120/208 Wye SCCR RATING:

EXISTING BRANCH PANEL: FS (LEFT)

CONNECTED LOAD: (kVA) 0.00 0.00

TIRE CHANGER -- 1 20 33 0.00 0.00 34 20 1 -- DISPATCH OFFICE LIGHTS

TIRE CHANGER -- 1 20 31 0.00 0.00 32 20 1 -- GARAGE CEILING FANS

SIGNAL ROOM -- 1 20 29 0.00 0.00 30 20 1 -- RECEPT BELOW PANEL

ASSEMBLY HALL EXHAUST -- 1 20 27 0.00 0.00 28 20 1 -- SIGNAL ROOM

SPARE -- 1 20 25 0.00 0.00 26 20 1 -- FIRINGLINE STRWL LIGHTS

UH-1, UH-2, UH-4, UH-5 12 1 20 23 0.00 0.18 24 20 1 12 RECEPT-ROOF

MAINT ROOM HEATER -- 1 20 21 0.00 0.00 22 20 1 12 UH-3, UH-6, UH-7, UH-8

AT&T RECEPT -- 1 20 19 0.00 0.00 20 20 1 -- MAINT SHIP A/C

RIFLE RANGE SUMP PUMP -- 1 20 17 0.00 0.00 18 20 1 -- MAINT SHIP A/C

RIFLE RANGE LIGHTS EAST -- 1 20 15 0.00 0.00 16 20 1 -- RIFLE RANGE RECEPT

CLASSROOM & OFFICE LIGHTS -- 1 20 13 0.00 0.00 14 20 1 -- RIFLE RANGE LIGHTS WEST

GARAGE LIGHTS WEST... -- 1 20 11 0.00 0.00 12 20 1 -- UNIT STORAGE LIGHTS

GARAGE LIGHTS WEST -- 1 20 9 0.00 0.00 10 20 1 -- MAINT ROOM LIGHTS

GARAGE LIGHTS SOUTHEAST -- 1 20 7 0.00 0.00 8 20 1 -- OUTSIDE LIGHTS

GARAGE LIGHTS NORTHEAST -- 1 20 5 0.00 0.00 6 20 1 -- MAINT ROOM RECEPT

STOREROOM RECEPT -- 1 20 3 0.00 0.00 4 20 1 -- STOREROOM LIGHTS

GARAGE RECEPT WEST -- 1 20 1 0.00 0.00 2 20 1 -- GARAGE RECEPT EAST

IDENTIFICATION WIRE POLE AMP CKT

A kVA

B kVA

A kVA

B kVA

CKT AMP POLE WIRE IDENTIFICATION

BOLD ITALIC INDICATES PROPOSED DEVICE

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 3 MCB RATING: N/A

SUPPLY FROM: PHASES: 1 MAINS TYPE: MLO

LOCATION: FOOD STORAGE ARE... VOLTS: 120/208 Single SCCR RATING:

EXISTING BRANCH PANEL: LP-A

CONNECTED LOAD: (kVA) 0.00 0.00 0.00

49 -- -- 50

47 -- -- 48SPACE -- 3 --

45 -- -- 46

-- 3 -- SPACE

43 0.00 0.00 44

ASSEMBLY HALL -- 2 20

41 0.00 0.00 42

225 2 -- BOILER ROOM POWER

39 -- -- 40

37 -- -- 38SPACE -- 3 --

35 -- -- 36

-- 3 -- SPACE

33 -- -- 34

31 -- -- 32SPACE -- 3 --

29 -- -- 30

-- 3 -- SPACE

27 0.00 0.00 28

GARAGE -- 2 20

25 0.00 0.00 26

125 2 -- SPARE

23 -- -- 24

21 -- -- 22SPACE -- 3 --

19 -- -- 20

-- 3 -- SPACE

17 0.00 0.00 18

BOILER ROOM LIGHTS -- 2 100

15 0.00 0.00 16

SPACE -- 1 -- 13 -- 0.00 14

50 3 -- UNKNOWN

11 -- 0.00 12

9 -- 0.00 10SPACE -- 3 --

7 -- 0.00 8

50 3 --

OMS COMPRESSOR, SINGLE

PHASE FOR NEW

COMPRESSOR

5 -- 0.00 6

3 -- 0.00 4SPACE -- 3 --

1 -- 0.00 2

60 3 --

BASEMENT EXHAUST SMALL

COMPRESSOR FAN

IDENTIFICATION WIRE POLE AMP CKT

A B C A B C

CKT AMP POLE WIRE IDENTIFICATION

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 4 MCB RATING: N/A

SUPPLY FROM: PHASES: 3 MAINS TYPE: MLO

LOCATION: FOOD STORAGE ARE... VOLTS: 120/208 Wye SCCR RATING:

EXISTING BRANCH PANEL: DP

CONNECTED LOAD: (kVA) 0.18 0.18 0.18

27 28

25 26

23 24

21 0.00 0.00 22

19 0.00 0.00 20OIL HEATER -- 3 50

17 0.00 0.00 18

50 3 -- NEW BUILDING/FURNACE

15 0.00 0.00 16

13 0.00 0.00 14PUMP P2 -- 3 50

11 0.00 0.00 12

50 3 -- PUMP P1

9 0.18 0.00 10

7 0.18 0.00 8PUMP P-3 8 3 50

5 0.18 0.00 6

50 3 -- BAR SUBPANEL

3 0.00 0.00 4

UNKNOWN -- 2 50

1 0.00 0.00 2

100 2 -- UNKNOWN

IDENTIFICATION WIRE POLE AMP CKT

A kVA

B kVA

C kVA

A kVA

B kVA

C kVA

CKT AMP POLE WIRE IDENTIFICATION

BOLD ITALIC INDICATES PROPOSED DEVICE

NOTES:

ENCLOSURE: TYPE 1

MOUNTING: SURFACE WIRES: 4 MCB RATING: N/A

SUPPLY FROM: PHASES: 3 MAINS TYPE: MLO

LOCATION: HEATER RM 124 VOLTS: 120/208 Wye SCCR RATING:

EXISTING BRANCH PANEL: PP1

Sheets
E-001 - ELECTRICAL NOTES AND SYMBOLS
EDP101 - 1ST FLOOR ELECTRICAL DEMOLITION PLAN
ED501 - ELECTRICAL DEMOLITION SCHEDULES
EL101 - 1ST FLOOR LIGHTING PLAN
EP101 - POWER PLAN
EP111 - ROOF POWER PLAN
E-501 - ELECTRICAL DETAILS
E-601 - ELECTRICAL SCHEDULES