502-16-04 Electrical 100 pct BID.pdf

PDF 10 MB Posted

Attached to
Z2DA--Proj. # 502-16-104 Replace HVAC System in Bldg. 2 Federal contract opportunity
Solicitation number
36C25620R0079
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--Proj. # 502-16-104 Replace HVAC System in Bldg. 2, newest first.
File Type Posted
502-16-104 Mechanical Rev. 1 Drwgs MH103 MH104 M504.pdf PDF
ADDENDUM NO. 0001.pdf PDF
EXHIBIT B PAST AND PRESENT PERFORMANCE QUESTIONNAIRE v2.docx DOCX document
502-16-104 010000 Gen Req Revision 5-18-20.docx DOCX document
502-16-104 Fire Protection 100 pct Bid.pdf PDF
Bldg 2 Asbestos Report.pdf PDF
502-16-104 Project Risk Assessment Bldg 2 HVAC 1-3-20.pdf PDF
502-16-104 Mechanical 100 pct Bid.pdf PDF
Wage Determination.txt TXT text file
EXHIBIT C SUBCONTRACTOR INFORMATION AND CONSENT v2.docx DOCX document
EXHIBIT F PROPOSAL INQUIRY FORM.docx DOCX document
502-16-104 Structural 100 pct Bid.pdf PDF
502-16-104 Electrical Rev. Drwg E-501.pdf PDF
EXHIBIT D CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY v2.docx DOCX document
36C25620R0079_3.docx DOCX document
EXHIBIT A PERFORMANCE RELEVANCY SURVEY v2.docx DOCX document
EXHIBIT E SURETY FORM.docx DOCX document
502-16-104 Combined Spec Set Replace HVAC Bldg 2.pdf PDF
502-16-104 Final SOW.docx DOCX document
Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

01Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

# 2

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

PH, Ø

A, AMP

AF

AFF

AFG

AHU

AT

AWG

C cd

DHC

EF

EG

ELEC

EMT

EWH

EXIST.

GND

GRS

HP

KAIC

KVA

KW

MAX.

MCB

MDP

MECH

MIN.

MLO

MS

NC

NEC

NEMA

NFPA

NIC

NTS

NO

NO.

PVC

R, REC

RGS

(SC)

SN

SPD

TYP

UL

UON

V

W

XFMR

PHASE,

AMPERE

AMP FRAME

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

AIR HANDLING UNIT

AMP TRIP

AMERICAN WIRE GAUGE

CONDUIT

CANDELA

DIRECT DIGITAL CONTROLS

EXHAUST FAN

EQUIPMENT GROUND

ELECTRIC

ELECTRICAL METALLIC TUBING

ELECTRIC WATER HEATER

EXISTING

GROUND

GALVANIZED RIGID STEEL

HORSEPOWER

THOUSAND AMPS INTERRUPTING CURRENT

KILO-VOLTAMPERES

KILOWATT

MAXIMUM

MAIN CIRCUIT BREAKER

MAIN DISTRIBUTION PANELBOARD

MECHANICAL

MINIMUM

MAIN LUGS ONLY

MOTOR STARTER

NORMALLY CLOSED

NATIONAL ELECTRICAL CODE

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NATIONAL FIRE PROTECTION ASSOCIATION

NOT IN CONTRACT

NOT TO SCALE

NORMALLY OPEN

NUMBER

POLYVINYL CHLORIDE

RECEPTACLE

RIGID GALVANIZED STEEL

SHARED CIRCUIT

SOLID NEUTRAL

SURGE PROTECTION DEVICE

TYPICAL

UNDERWRITERS LABORATORY

UNLESS OTHERWISE NOTED

VOLTS

WATT, WIRE

TRANSFORMER

ELECTRICAL LEGEND:

GFI = GROUND FAULT CIRCUIT INTERRUPTER

WIRING SYSTEM-BRANCH OR FEEDER CIRCUIT

BRANCH OR FEEDER CIRCUIT HOMERUN TO PANELBOARD,

SWITCHBOARD, MOTOR CONTROL CENTER, ETC. SUBSCRIPT

DENOTES PANELBOARD, SWITCHBOARD, MOTOR CONTROL

CENTER, ETC. AND OVERCURRENT PROTECTION DEVICE

NUMBER.

120V DUPLEX RECEPTACLE, MOUNTED 18" AFF UNO

MODIFIERS FOR RECEPTACLES:

WP = WEATHERPROOF

EXISTING PANELBOARD 208Y/120V, SEE PANEL SCHEDULE

EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULE

ROOM NUMBER

DEMOLITION NOTE SYMBOL

NEW WORK NOTE SYMBOL

1. ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE

INSTALLED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, THE

MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES, ALL APPLICABLE

LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND WITH THE LATEST

EDITION OF THE NATIONAL ELECTRICAL CODE.

2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS

WHERE THE BUILDING CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.

3. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE

AROUND ALL PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND

ROOFS IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL

CODE, UL LISTING REQUIREMENT AND THE APPLICABLE BUILDING CODES. REFER TO

THE ARCHITECTURAL DRAWINGS AND THE OWNER'S EXISTING AS-BUILT/RECORD

DRAWINGS, VERIFY CONSTRUCTION RATINGS AND PROVIDE PENETRATION

ASSEMBLIES SUITABLE FOR THE PARTICULAR CONSTRUCTION.

4. VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING ACCESSORIES, TRIMS AND ALL

REQUIRED MOUNTING HARDWARE TO SUIT THE PARTICULAR INSTALLATION.

5. PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING

CONSTRUCTION.

6. BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG MINIMUM.

7. COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION

SO AS TO AVOID CONFLICT DURING CONSTRUCTION.

EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM

SIGNAGE) OF EQUIPMENT LOCATION, OR SPARE, OR SPACE.

9. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE

PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT

PRODUCTS TO A PARTICULAR MANUFACTURER. PRODUCTS DEEMED EQUAL AND

APPROVED BY THE DESIGNER WILL BE ACCEPTED.

10. ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER,

AND/OR PARTICULAR EQUIPMENT MANUFACTURER'S SPECIFICATIONS.

11. CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE

TERMINATED ON THE DEVICE'S SCREW TERMINALS.

12. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR

EQUIPMENT UNLESS NOTED OTHERWISE.

13. ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.

14. ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE

NOTED.

15. ALL CONDUIT SHALL BE GRS, IMC OR EMT UNLESS OTHERWISE NOTED.

16. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE

LABEL LISTED BY AN APPROVED THIRD PARTY TESTING AGENCY.

8. ALL MODIFIED PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING

GENERAL REQUIREMENTS ABBREVIATIONS:

& SPECIAL NOTES

ABBREVIATIONS, LUMINAIRE SCHEDULE,

GENERAL REQUIREMENTS, LEGEND,

MJJ GDA

E-001

LUMINAIRE SCHEDULE

SYMBOL LABEL TYPE OF LAMP

BALLAST/

DRIVER

WATTS/

FIXTURE

VOLTAGE DESCRIPTION MANUFACTURER/CATALOG NUMBER

NOTES:

1. MANUFACTURER AND CATALOG NUMBERS SHOWN ARE FOR BASIS OF DESIGN, DESCRIPTIVE AND QUALITY STANDARDS ONLY, NOT TO BE USED FOR ORDERING WITHOUT VERIFICATION AND APPROVAL. CONTRACTOR TO PROVIDE PRODUCT OR EQUAL FOR

APPROVAL BY COR, ARCHITECT AND ENGINEER. ENGINEER IS NOT RESPONSIBLE FOR MISMATCHED OR INACCURATE PART NUMBERS.

2. FOR ALL LED LIGHT FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE SWITCHED OR CONTROLLED STATE FOLLOWING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC PROTECTIVE MEASURES DISABLE THE LED LAMPS.

PROVIDE WITH THE FIXTURE SUBMITTALS A LETTER OR STATEMENT OF WARRANTY FROM THE MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED OR

CONTROLLED STATE AUTOMATICALLY. DEMONSTRATE FIXTURE PERFORMANCE DURING COMMISSIONING. CONTRACTOR SHALL CORRECT ANY DEFICIENCIES AT CONTRACTOR EXPENSE.

3. LIGHT FIXTURES SHALL BE UL LISTED FOR DAMP LOCATIONS.

3922 LUMEN LED

1 ELECTRONIC

DRIVER

30 MVOLT

HALL LED 2X4 LENSED, GRID LAY IN TROFFER

LITHONIA 2GTL-F-4-40L-FW-GZ10-LP835

3922 LUMEN LED

1 ELECTRONIC

DRIVER

30 MVOLT

HALL LED 2X4 LENSED, GRID LAY IN TROFFER WITH EMERGENCY BATTERY BACK

UP

LITHONIA 2GTL-F-4-40L-FW-GZ10-LP835-EL14L

METHOD OF VOLTAGE DROP

CALCULATIONS

USING OHM'S LAW AND THE KNOWN RESISTIVITY CONSTANT OF CONDUCTOR

METAL (CIRCULAR MIL-OHM PER FOOT) FOR COPPER CONDUCTORS, CALCULATE

THE REQUIRED WIRE SIZE NECESSARY SO AS NOT TO EXCEED THE

RECOMMENDED VOLTAGE DROP OF 3% FOR BRANCH CIRCUIT CONDUCTORS.

METHOD OF SHORT CIRCUIT

CURRENT CALCULATIONS

SHORT CIRCUIT CURRENT CALCULATIONS SHALL BE PERFORMED ON THE

ELECTRICAL SYSTEM USING A BOLTED THREE PHASE FAULT CONDITION FOR

CALCULATIONS TO ACHIEVE MAXIMUM THERMAL AND MECHANICAL STRESS TO

THE SYSTEM FOR CALCULATION PURPOSES. EXISTING SHORT CIRCUIT VALUES

WILL BE USED OUTSIDE THE WORK ARE, FOR THE STARTING POINT OF THE

CALCULATIONS.

ARC-FLASH STUDY &

IDENTIFICATION REQUIREMENTS

PROVIDE ARC FLASH WARNING LABELS ON ALL NEW ELECTRICAL DISTRIBUTION

EQUIPMENT. SEE SPECIFICATION SECTION 26-05-73 OVERCURRENT PROTECTIVE

DEVICE COORDINATION STUDY. LABELING SHALL MEET NFPA-70E

REQUIREMENTS AND INCLUDE CALCULATED CAL/CM^2 VALUES AND LIST

PERSONAL PROTECTIVE EQUIPMENT (PPE) CATEGORY LEVEL REQUIREMENTS

SPECIFIC TO EACH PIECE OF INSTALLED EQUIPMENT. \

AN EXISTING ELECTRICAL SYSTEM ARC FLASH STUDY IS ON RECORD AND SHALL

BE MADE AVAILABLE BY THE VA FOR USE IN PREPARING THE ARC FLASH STUDY

REQUIRED FOR THIS PROJECT. SEE SECTION 26-05-73 PARTS 1.1.C & 1.6.C FOR

REQUIREMENTS REGARDING THE EXTENT OF THE STUDY.

2983 LUMEN LED

1 ELECTRONIC

DRIVER

23 MVOLT

OFFICE LED 2X4 LENSED, GRID LAY IN TROFFER

LITHONIA 2GTL-F-4-30L-FW-EZ1-LP835

2983 LUMEN LED

1 ELECTRONIC

DRIVER

23 MVOLT

OFFICE LED 2X4 LENSED, GRID LAY IN TROFFER WITH EMERGENCY BATTERY

BACK UP

LITHONIA 2GTL-F-4-30L-FW-EZ1-LP835-EL14L

DISCONNECT SWITCH SYMBOL

SMOKE DUCT DETECTOR

MOTORIZED DAMPER

SDT

MOD

16. BRANCH CONDUITS ARE 3/4"C. WITH (3)-#12 AWG, UON.

1500 LUMEN LED

1 ELECTRONIC

DRIVER

18 MVOLT 6" DIAMETER PENDANT MOUNT LED LITHONIA LDN6CYL-35/15-LO6AR-L55-MVOLT-GZ10-PM-DWHG

1500 LUMEN LED

1 ELECTRONIC

DRIVER

18 MVOLT LITHONIA LDN6CYL-35/15-LO6AR-L55-MVOLT-GZ10-FCM-DWHG6" DIAMETER CEILING MOUNT LED

DocuSign Envelope ID: B9D4F131-B263-4860-8434-0C5CADDF2C68

1/8/2020

SERVICE ROOM

TRANSFORMER ROOM

BATTERY ROOM

PIT

ELEV.

CWP 2-2

CWP 2-1

CWP 2-4

CWP 2-3

HWP 2-5, 2-6

CWP 2-5

CWP 2-6

HWP 2-2

HWP 2-1

ELECTRICAL DEMOLITION PLAN - BASEMENT

SCALE: 1/8" = 1'-0"

ELECTRICAL DEMOLITION PLAN - BASEMENT

MJJ GDA

ED101

WALL RATING LEGEND

N

KEY PLAN

SCALE: NO SCALE

BUILDING 2

TRUE

AREA OF WORK

KEY NOTES:

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

# 2

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

S S S S

02 11

1. DISCONNECT, REMOVE AND DEMOLISH

CHILLED WATER PUMP, COMPLETE. SEE

MECHANICAL SHEET FOR MORE

INFORMATION.

2. EXISTING PANEL TO REMAIN FOR USE WITH

NEW EQUIPMENT. PANELS SHOWN FOR

CONTRACTORS KNOWLEDGE.

3. DISCONNECT, REMOVE AND DEMOLISH HOT

WATER PUMP, COMPLETE. SEE

PHASING/MECHANICAL PLANS FOR MORE

INFORMATION.

0 4 8 16

N

O

R

T

H

TRUE

A. CONTRACTOR SHALL BE RESPONSIBLE FOR

TRACING AND IDENTIFYING CIRCUITS AND

CONDUITS THAT ORIGINATE, PASS THROUGH

OR TERMINATE IN THE AREA OF WORK.

MAINTAIN CIRCUIT CONTINUITY TO ALL

CIRCUITS WHICH ARE NOT COMPLETELY

REMOVED.

B. CONTRACTOR TO DISCONNECT AND REMOVE

ELECTRICAL CONNECTION TO HVAC EQUIPMENT

AND OTHER ELECTRICAL DEVICES. REMOVE

CONDUCTORS AND CONDUIT BACK TO

PANELBOARD SERVING EQUIPMENT OR TO THE

POINT WHERE OTHER REMAINING LOADS ARE

CONNECTED. MARK EXISTING OVERCURRENT

PROTECTION DEVICE AS "SPARE (UNUSED)"

AND TURN "OFF" WHERE NOT REUSED BACK TO

POINT OF JUNCTURE WITH SYSTEMS IN USE.

SEAL WATER TIGHT ANY PENETRATIONS THAT

REMAIN AS PART OF DEMOLITION.

C. CONDUIT/BOXES SHALL HAVE ELECTRICAL

WIRING REMOVED COMPLETELY AND NOT JUST

MADE "SAFE". CONDUIT/BOXES SHALL BE

REMOVED WHERE PRACTICAL WITHOUT

CREATING ADDITIONAL DEMOLITION/WORK. NO

EMPTY CONDUITS SHALL REMAIN.

D. WHERE CONDUIT IS REMOVED FROM EXISTING

RATED ASSEMBLY NOT SUBJECT TO

DEMOLITION, THE REMAINING PENETRATION

SHALL BE PATCHED/REPAIRED TO MAINTAIN

THE RATING OF THE ASSEMBLY.

CORRIDOR

LOBBY

ELEV.

ELEV.

DAV

102A

DAV

OFFICE

OFFICES

123A

STORAGE

CLASSROOM

OFFICE

STAIRS

DVB

F. TOILET

STOR.

SUPPLIES

117K

BREAK ROOM

117J

FIRE ALARM

117H

SPECIALIST

114G

OFFICE

SECRETARY

ASSOC. CHIEF

BIO HAZARD

RMS

M. TOILET

STORAGE

INSTRUCTOR

NURSING

INSTRUCTOR

NURSING

NURSING ED.

LOADING

ELEC.

RMS

117A

OFFICE

117B

OFFICE

117C

TESTING

117D

OFFICE

WAITING

EDUCATION

DOCTOR'S

BIO-FEED

BACK

ENTRY

117L

TECHN'S

RMS

117E

CHIEF'S OFFICE

117F

PSYCHOLOGY

VOC. REHAB

BOARD

DVB

OFFICES

LIBRARY

IT

TOILET

STORAGE

138A

STAIRS

ROOM

126A

STAIR

COPY VALEX

OFFICE VALEX

127A

TELLER/LOBBY

VAULT

127B

OFFICE

126E

CONFERENCE

126B

OFFICE

126D

CORRIDOR

TOILET

COMPUTER

128B

BREAK

LIBRARY

128E

128A

CHECKOUT

128C

128D

TOILET

128F

LIBRARY

LIBRARY

128G

128H

ELECT.

LIBRARY

DOCK

ID.4

OFFICE

F.C.U.

INSTRUCTOR

NURSING

126C

CORRIDOR

CORRIDOR

RECEPTION

116C

116A

OFFICE

UNION

116B

SHOP

ELECT.

TELE.

104A

RM

PHASE 1

PHASE 3

PHASE 2

ELECTRICAL DEMOLITION PLAN - 1ST FLOOR

MJJ GDA

ED102

WALL RATING LEGEND

N

KEY PLAN

SCALE: NO SCALE

BUILDING 2

TRUE

AREA OF WORK

KEY NOTES:

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

# 2

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

S S S S

03 11

1. REMOVE AND DEMOLISH MECHANICAL

EQUIPMENT CIRCUIT AND CONTROLS,

COMPLETE. SEE SHEET "MD-102" FOR MORE

INFORMATION.

ELECTRICAL DEMOLITION PLAN - 1ST FLOOR

SCALE: 1/8" = 1'-0"

0 4 8 16

N

O

R

T

H

TRUE

A. CONTRACTOR SHALL BE RESPONSIBLE FOR

TRACING AND IDENTIFYING CIRCUITS AND

CONDUITS THAT ORIGINATE, PASS THROUGH

OR TERMINATE IN THE AREA OF WORK.

MAINTAIN CIRCUIT CONTINUITY TO ALL

CIRCUITS WHICH ARE NOT COMPLETELY

REMOVED.

B. CONTRACTOR TO DISCONNECT AND REMOVE

ELECTRICAL CONNECTION TO HVAC EQUIPMENT

AND OTHER ELECTRICAL DEVICES. REMOVE

CONDUCTORS AND CONDUIT BACK TO

PANELBOARD SERVING EQUIPMENT OR TO THE

POINT WHERE OTHER REMAINING LOADS ARE

CONNECTED. MARK EXISTING OVERCURRENT

PROTECTION DEVICE AS "SPARE (UNUSED)"

AND TURN "OFF" WHERE NOT REUSED BACK TO

POINT OF JUNCTURE WITH SYSTEMS IN USE.

SEAL WATER TIGHT ANY PENETRATIONS THAT

REMAIN AS PART OF DEMOLITION.

C. CONDUIT/BOXES SHALL HAVE ELECTRICAL

WIRING REMOVED COMPLETELY AND NOT JUST

MADE "SAFE". CONDUIT/BOXES SHALL BE

REMOVED WHERE PRACTICAL WITHOUT

CREATING ADDITIONAL DEMOLITION/WORK. NO

EMPTY CONDUITS SHALL REMAIN.

D. WHERE CONDUIT IS REMOVED FROM EXISTING

RATED ASSEMBLY NOT SUBJECT TO

DEMOLITION, THE REMAINING PENETRATION

SHALL BE PATCHED/REPAIRED TO MAINTAIN

THE RATING OF THE ASSEMBLY.

PHASE 1

PHASE 3

PHASE 2

CORRIDOR

LOBBY

ELEV.

ELEV.

DAV

102A

DAV

OFFICE

OFFICES

123A

STORAGE

CLASSROOM

OFFICE

STAIRS

DVB

F. TOILET

STOR.

SUPPLIES

117K

BREAK ROOM

117J

FIRE ALARM

117H

SPECIALIST

114G

OFFICE

SECRETARY

ASSOC. CHIEF

111BIO HAZARD

RMS

M. TOILET

STORAGE

INSTRUCTOR

NURSING

INSTRUCTOR

NURSING

NURSING ED.

LOADING

ELEC.

RMS

117A

OFFICE

117B

OFFICE

117C

TESTING

117D

OFFICE

WAITING

EDUCATION

DOCTOR'S

BIO-FEED

BACK

ENTRY

117L

TECHN'S

RMS

117E

CHIEF'S OFFICE

117F

PSYCHOLOGY

VOC. REHAB

BOARD

DVB

OFFICES

LIBRARY

IT

TOILET

STORAGE

138A

STAIRS

ROOM

126A

STAIR

COPY VALEX

OFFICE VALEX

127A

TELLER/LOBBY

VAULT

127B

OFFICE

126E

CONFERENCE

126B

OFFICE

126D

CORRIDOR

TOILET

COMPUTER

128B

BREAK

LIBRARY

128E

128A

CHECKOUT

128C

128D

TOILET

128F

LIBRARY

LIBRARY

128G

128H

ELECT.

LIBRARY

DOCK

ID.4

OFFICE

F.C.U.

INSTRUCTOR

NURSING

126C

CORRIDOR

CORRIDOR

RECEPTION

116C

116A

OFFICE

UNION

116B

SHOP

ELECT.

TELE.

104A

RM

ELECTRICAL CEILING DEMOLITION PLAN - 1ST FLOOR

SCALE: 1/8" = 1'-0"

- 1ST FLOOR

ELECTRICAL CEILING DEMOLITION PLAN

MJJ GDA

ED103

WALL RATING LEGEND

N

KEY PLAN

SCALE: NO SCALE

BUILDING 2

TRUE

AREA OF WORK

KEY NOTES:

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

# 2

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

S S S S

04 11

1. BASE BID: REMOVAL OF ALL EXISTING LIGHT

FIXTURES AND RE-USE EXISTING LIGHT

FIXTURES AFTER RENOVATION WORK IN

CEILING IS COMPLETE.

2. DEDUCT ALTERNATIVE: INCLUDES REMOVAL

OF ALL EXISTING LIGHT FIXTURES AND

REPLACING WITH NEW, ON FIRST FLOOR.

0 4 8 16

N

O

R

T

H

TRUE

A. CONTRACTOR SHALL BE RESPONSIBLE FOR

TRACING AND IDENTIFYING CIRCUITS AND

CONDUITS THAT ORIGINATE, PASS THROUGH

OR TERMINATE IN THE AREA OF WORK.

MAINTAIN CIRCUIT CONTINUITY TO ALL

CONNECTIONS WHICH ARE NOT COMPLETELY

REMOVED.

B. CONTRACTOR TO DISCONNECT AND REMOVE

ELECTRICAL CONNECTIONS TO AS NEW CEILING

WORK REQUIRES EQUIPMENT LIGHTING &

CEILING MOUNTED DEVICES. REMOVE

CONDUCTORS AND CONDUIT BACK TO

PANELBOARD SERVING EQUIPMENT OR TO THE

POINT OF JUNCTURE WHERE OTHER LOADS

REMAIN CONNECTED. MARK EXISTING

OVERCURRENT PROTECTION DEVICE AS

"SPARE (UNUSED)" AND TURN "OFF" WHERE NOT

REUSED. SEAL WATER TIGHT ANY

PENETRATIONS THAT REMAIN AS PART OF

DEMOLITION.

C. CONDUIT/BOXES SHALL HAVE ELECTRICAL

WIRING REMOVED COMPLETELY AND NOT JUST

MADE "SAFE". CONDUIT/BOXES SHALL BE

REMOVED WHERE PRACTICAL WITHOUT

CREATING ADDITIONAL DEMOLITION/WORK. NO

EMPTY CONDUITS SHALL REMAIN.

D. WHERE CONDUIT IS REMOVED FROM EXISTING

RATED ASSEMBLY NOT SUBJECT TO

DEMOLITION, THE REMAINING PENETRATION

SHALL BE PATCHED/REPAIRED TO MAINTAIN

THE RATING OF THE ASSEMBLY.

E. TIE-UP AND PROTECT AUXILIARY SYSTEM

COMPONENTS TO BE RE-INSTALLED AT

EXISTING LOCATIONS IN CONJUNCTION WITH

NEW CEILING AND EXISTING ASSOCIATED

ELECTRICAL CONNECTIONS. WIRING AND

CONNECTIONS SHALL REMAIN FOR USE WITH

DEVICES IN CONJUNCTION WITH NEW CEILING.

EXISTING COMPONENTS TO REMAIN

FUNCTIONAL DURING CONSTRUCTION.

COMPONENTS EXPECTED TO BE ENCOUNTERED

INCLUDE:

1. FIRE/LIFE SAFETY: SMOKE

ALARMS,STROBES, HEAT SENSORS, ETC.

2. WIRELESS ACCESS POINTS (DATA,

CELLULAR)

3. PUBLIC ADDRESS AND PAGING SYSTEM

SPEAKERS

4. SURVEILLANCE CAMERAS AND INTRUSION

DETECTION

5. EMERGENCY/EGRESS LIGHTING AND

SIGNS

6. OTHER ELECTRICALLY CONENCTED

DEVICES ENCOUNTERED NOT LISTED

HERE

F. EXISTING LIGHTING CONTROLS ARE TO REMAIN.

CONTRACTOR SHALL DISCONNECT AND

REMOVE LUMIAIRES AND ACCESSORIES,

COMPLETE. AFTER CEILING RENOVATION WORK

IS COMPLETE, CONTRACTOR SHALL RE-INSTALL

LIGHTING WITH ALL COMPONENTS AND

ACCESSORIES FOR FULLY FUNCTIONING

SYSTEM.

PANEL '4-NX'

MCC-AC

ELECTRICAL DEMOLITION PLAN - ATTIC AND ROOF

SCALE: 1/8" = 1'-0"

ROOF

ELECTRICAL DEMOLITION PLAN - ATTIC &

MJJ GDA

ED104

WALL RATING LEGEND

N

KEY PLAN

SCALE: NO SCALE

BUILDING 2

TRUE

AREA OF WORK

KEY NOTES:

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

# 2

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

S S S S

05 11

1. EXISTING AHU-1 TO BE DEMOLISHED.

DISCONNECT AND REMOVE, COMPLETE. SEE

SHEET 'MD-105' FOR MORE INFORMATION.

2. EXISTING EXHAUST FAN TO BE DEMOLISHED.

DISCONNECT AND REMOVE, COMPLETE. SEE

SHEET 'MD-105' FOR MORE INFORMATION.

3. REMOVE EXISTING STARTER COMPONENTS

TO BE REPLACED WITH NEW CIRCUIT

BREAKERS FOR NEW AHU'S.

4. EXISTING AIR HANDLING UNIT TO BE

DEMOLISHED. DISCONNECT AND REMOVE,

COMPLETE. SEE SHEET 'MD-105' FOR MORE

INFORMATION.

5. EXISTING UTILITY RETURN FAN TO BE

DEMOLISHED. DISCONNECT AND REMOVE,

COMPLETE. SEE SHEET 'MD-105' FOR MORE

INFORMATION.

0 4 8 16

N

O

R

T

H

TRUE

A. CONTRACTOR SHALL BE RESPONSIBLE FOR

TRACING AND IDENTIFYING CIRCUITS AND

CONDUITS THAT ORIGINATE, PASS THROUGH

OR TERMINATE IN THE AREA OF WORK.

MAINTAIN CIRCUIT CONTINUITY TO ALL

CIRCUITS WHICH ARE NOT COMPLETELY

REMOVED.

B. CONTRACTOR TO DISCONNECT AND REMOVE

ELECTRICAL CONNECTION TO HVAC EQUIPMENT

AND OTHER ELECTRICAL DEVICES. REMOVE

CONDUCTORS AND CONDUIT BACK TO

PANELBOARD SERVING EQUIPMENT OR TO THE

POINT WHERE OTHER REMAINING LOADS ARE

CONNECTED. MARK EXISTING OVERCURRENT

PROTECTION DEVICE AS "SPARE (UNUSED)"

AND TURN "OFF" WHERE NOT REUSED BACK TO

POINT OF JUNCTURE WITH SYSTEMS IN USE.

SEAL WATER TIGHT ANY PENETRATIONS THAT

REMAIN AS PART OF DEMOLITION.

C. CONDUIT/BOXES SHALL HAVE ELECTRICAL

WIRING REMOVED COMPLETELY AND NOT JUST

MADE "SAFE". CONDUIT/BOXES SHALL BE

REMOVED WHERE PRACTICAL WITHOUT

CREATING ADDITIONAL DEMOLITION/WORK. NO

EMPTY CONDUITS SHALL REMAIN.

D. WHERE CONDUIT IS REMOVED FROM EXISTING

RATED ASSEMBLY NOT SUBJECT TO

DEMOLITION, THE REMAINING PENETRATION

SHALL BE PATCHED/REPAIRED TO MAINTAIN

THE RATING OF THE ASSEMBLY.

SM

G/SX-22

G/SX-41

G/SX-33

N2GS1-1

N2GS1-3

N2GS1-31

N2GS1-28

N2GS1-16

N2GS1-18

N2GS1-43

G/SX-44

G/SX-42

PHASE 3

PHASE 2

LOBBY

ELEV.

ELEV.

DAV

OFFICE

OFFICES

123A

STORAGE

CLASSROOM

OFFICE

DVB

F. TOILET

STOR.

SUPPLIES

117K

BREAK ROOM

117J

FIRE ALARM

117H

SPECIALIST

114G

SECRETARY

ASSOC. CHIEF

BIO HAZARD

RMS

M. TOILET

STORAGE

INSTRUCTOR

NURSING

INSTRUCTOR

NURSING

NURSING ED.

LOADING

ELEC.

RMS

117A

OFFICE

117B

OFFICE

TESTING

117D

OFFICE

WAITING

EDUCATION

DOCTOR'S

BIO-FEED

ENTRY

117L

TECHN'S

RMS

117E

CHIEF'S OFFICE

117F

PSYCHOLOGY

VOC. REHAB

BOARD

DVB

OFFICES

LIBRARY

IT

TOILET

STORAGE

138A

STAIRS

ROOM

126A

STAIR

COPY VALEX

OFFICE VALEX

127A

TELLER/LOBBY

VAULT

127B

OFFICE

126E

CONFERENCE

126B

OFFICE

126D

TOILET

COMPUTER

128B

BREAK

LIBRARY

128E

128A

CHECKOUT

128C

128D

TOILET

128F

LIBRARY

LIBRARY

128G

128H

ELECT.

LIBRARY

DOCK

ID.4

OFFICE

F.C.U.

INSTRUCTOR

NURSING

126C

CORRIDOR

CORRIDOR

RECEPTION

116C

116A

OFFICE

UNION

116B

SHOP

G/SX-19

117C

TESTING

BIO-FEED

BACK

ELECTRICAL CEILING PLAN - 1ST FLOOR

SCALE: 1/8" = 1'-0"

WALL RATING LEGEND

N

KEY PLAN

SCALE: NO SCALE

BUILDING 2

TRUE

AREA OF WORK

KEY NOTES:

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

# 2

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

S S S S

1. NEW LUMINAIRES TO UTILIZE EXISTING

CIRCUITS, LIGHTING CONTROLS, AND

DEVICES. SEE ARCHITECTURAL SHEETS FOR

REFLECTED CEILIING PLAN. SEE SHEET E-001

FOR LUMINAIRE SCHEDULE.

- 1ST FLOOR

ELECTRICAL CEILING INSTALLATION PLAN

MJJ GDA

EL101

06 11

A. EXISTING CIRCUIT AND LIGHTING CONTROLS SHALL BE

REUSED WITH NEW CONDITIONS. SALVAGE EXISTING LED

TYPE LUMINAIRES TO OWNER.

B. ALTERNATE DEDUCT-1: RE-INSTALL EXISTING LUMINAIRES

IN EXISTING LOCATIONS AND OMIT NEW LUMINARES.

C. LUMINAIRE SCHEDULE IS FOUND ON SHEET E-001.

D. RE-INSTALL EXISTING AUXILLIARY COMPONENTS IN

PREVIOUSLY INSTALLED LOCATIONS, IN CONJUNCTIONS

WITH NEW CEILING.

0 4 8 16

N

O

R

T

H

TRUE

SERVICE ROOM

TRANSFORMER ROOM

BATTERY ROOM

PIT

ELEV.

N-2-B-S-3-7, 9, 11

N-2-B-S-3-8, 10, 12

N-2-B-N-3-13, 15, 17

N-2-B-N-3-2, 4, 6

2-CWP-1

2-CWP-2

2-CWP-3

2-CWP-4

N-2-B-S-3-21

N-2-B-S-3-21

BOX FAN

BOX FAN

N-2-B-N-3-21

N-2-B-N-3-21

BOX FAN

BOX FAN

SM

SM

SM

SM

ELECTRICAL POWER PLAN - BASEMENT

SCALE: 1/8" = 1'-0"

1. NEW CHILLED WATER PUMPS SHALL UTILIZE

EXISTING CIRCUITS FROM DEMOLISHED

CHILLED WATER PUMPS.

2. NEW BOX FAN EQUIPMENT LOCATION. 120V, 1

PHASE, 9.8A, TYPICAL. SEE SHEET E-601 FOR

PANEL CIRCUIT INFORMATION.

ELECTRICAL POWER PLAN - BASEMENT

MJJ GDA

E-101

WALL RATING LEGEND

N

KEY PLAN

SCALE: NO SCALE

BUILDING 2

TRUE

AREA OF WORK

KEY NOTES:

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

# 2

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

S S S S

07 11

0 4 8 16

N

O

R

T

H

TRUE

A. SEE EQUIPMENT CONNECTION SCHEDULE

ON E-601 FOR ADDITIONAL INSTALLATION

DETAILS.

B. INSTALL MOTOR CONTROLLERS AS

REQUIRED FOR MECHANICAL INSTALLATION.

SEE MECHANICAL SCHEDULES ON SHEET

M-501 FOR DETAILS.

2-FCU-13A

2-FCU-02

2-FCU-04

2-FCU-05

2-FCU-06

2-FCU-08

2-FCU-01

2-FCU-03

2-FCU-07B

2-FCU-07A

2-FCU-09

2-FCU-10B

2-FCU-10C

2-FCU-11B

2-FCU-11C

2-FCU-11D

2-FCU-11E

2-FCU-11F

2-FCU-11G

2-FCU-11A

2-FCU-13B

2-FCU-14

2-FCU-15

2-FCU-17

2-FCU-18

2-FCU-16

DAC-1

2-FCU-19

ACCU-1

2-FCU-21

2-FCU-22

2-FCU-23

2-FCU-25

2-FCU-24

2-FCU-26

2-FCU-28

2-FCU-27

2-FCU-30

2-FCU-31

ACCU-2

DAC-2

DAC-3

ACCU-3

2-FCU-36

2-FCU-34

2-FCU-38

2-FCU-33

2-FCU-32

2-FCU-39

2-FCU-35

2-FCU-29

2-FCU-37

2-FCU-42

2-FCU-44

2-FCU-41

2-FCU-40

2-FCU-43

2-FCU-45

2-FCU-10A

2-FCU-46

SM

SM

SM

2-FCU-47

PHASE 3

PHASE 2

LOBBY

ELEV.

ELEV.

DAV

OFFICE

OFFICES

123A

STORAGE

CLASSROOM

OFFICE

DVB

F. TOILET

STOR.

SUPPLIES

117K

BREAK ROOM

117J

FIRE ALARM

117H

SPECIALIST

114G

SECRETARY

ASSOC. CHIEF

BIO HAZARD

RMS

M. TOILET

STORAGE

INSTRUCTOR

NURSING

INSTRUCTOR

NURSING

NURSING ED.

LOADING

ELEC.

RMS

117A

OFFICE

117B

OFFICE

117C

TESTING 117D

OFFICE

WAITING

EDUCATION

DOCTOR'S

BIO-FEED

BACK

ENTRY

117L

TECHN'S

RMS

117E

CHIEF'S OFFICE

117F

PSYCHOLOGY

VOC. REHAB

BOARD

DVB

OFFICES

LIBRARY

IT

TOILET

STORAGE

138A

STAIRS

ROOM

126A

STAIR

COPY VALEX

OFFICE VALEX

127A

TELLER/LOBBY

VAULT

127B

OFFICE

126E

CONFERENCE

126B

OFFICE

126D

CORRIDOR

TOILET

COMPUTER

128B

BREAK

LIBRARY

128E

128A

CHECKOUT

128C

128D

TOILET

128F

LIBRARY

LIBRARY

128G

128H

ELECT.

LIBRARY

DOCK

ID.4

OFFICE

F.C.U.

INSTRUCTOR

NURSING

126C

CORRIDOR

CORRIDOR

RECEPTION

116C

116A

OFFICE

UNION

116B

SHOP

PHASE 1

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

S

M

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

S

M

SMSM

S

M

SM

S

MSMS

M

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

S

M

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

S

M

2-FCU-48

2-FCU-11H

SM

2-FCU-11

2-FCU-20

SM

2-FCU-49

2-EF-ELEC

2-EF-BIO

SM

SM

ELECTRICAL POWER PLAN - 1ST FLOOR

SCALE: 1/8" = 1'-0"

WALL RATING LEGEND

N

KEY PLAN

SCALE: NO SCALE

BUILDING 2

TRUE

AREA OF WORK

KEY NOTES:

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

# 2

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

S S S S

1. INSTALL NEW 100A/3P CIRCUIT BREAKER INTO

DISTRIBUTION BOARD '2-MDPN-A' (LOCATED IN

ELECTRICAL ROOM 110) FOR NEW PANEL

'N-2-G-S-2'. SEE SHEET E-601 FOR ONE LINE

DIAGRAM.

2. CONNECT NEW PANEL TO EXISTING

PANELBOARD WITH (4)#2 & #8 GND IN 1.5"C.

ROUTE CONDUIT ABOVE CEILING AS SHOWN

ON DRAWING.

3. NEW ELECTRICAL POWER CONNECTION FOR

DDC CONTROLS AS SHOWN ON THIS SHEET.

ELECTRICAL POWER PLAN - 1ST FLOOR

MJJ GDA

E-102

08 11

0 4 8 16

N

O

R

T

H

TRUE

A. NEW FAN COIL UNIT CONNECTION.

ELECTRICAL POWER CONNECTION SHALL BE

INSTALL NEW 120V CIRCUITS TO NEW

MECHANICAL UNITS, UNO.

EQUIPMENT

DISH

ANTENNA

2-ERV-01

2-AH-1

2-AH-2

2-ERV-02

GFCI

GFCI

GFCI

2-4/NX-13

2-4/NX-13

2-4/NX-13

2-4/NX-13

MCC-AC-9

MCC-AC-3

MCC-AC-7

MCC-AC-8

PANEL '2-4/NX'

(IN ATTIC SPACE)

MCC-AC

2-4/NX-14

2-EF-SLEEP

2-EF-ATTIC

SM

SM

ELECTRICAL POWER PLAN - ROOF

SCALE: 1/8" = 1'-0"

WALL RATING LEGEND

N

KEY PLAN

SCALE: NO SCALE

BUILDING 2

TRUE

AREA OF WORK

KEY NOTES:

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

# 2

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

S S S S

1. NEW AIR HANDLING UNIT ELECTRICAL POWER

CONNECTION. SEE MECHANICAL SHEETS FOR

MORE INFORMATION.

2. NEW ENERGY RECOVERY VENTILATOR

ELECTRICAL POWER CONNECTION. SEE

MECHANICAL SHEETS FOR MORE

INFORMATION

3. NEW SERVICE RECEPTACLE ON STUB

PEDESTAL.

4. INSTALL NEW MECHANICAL EQUIPMENT

CIRCUIT BREAKERS IN EXISTING MCC.

PROVIDE COMPATIBLE EQUIPMENT FOR

EXISTING CUTLER-HAMMER 'UNITROL' MCC

5. CONNECT NEW SMOKE DUCT DETECTOR WITH

EXISTING FACP CONNECTION FROM EXISTING

MECHANICAL EQUIPMENT LOCATIONS.

6. NEW CIRCUIT FOR CHILLED WATER SUPPLY

HEAT TRACE. APPROX 75 LINEAR FEET. SEE

MECHANICAL SHEETS FOR MORE

INFORMATION.

ELECTRICAL POWER PLAN - ROOF

MJJ GDA

E-103

09 11

0 4 8 16

N

O

R

T

H

TRUE

A. SEE MECHANICAL EQUIPMENT CONNECTION

SCHEDULE ON SHEET E-601 FOR DETAILS.

System No.W-L-1001

June 15, 2005

F Ratings - 1, 2, 3 and 4 Hr (See Items 2 and 3)

T Ratings - 0, 1, 2, 3, and 4 Hr (See Item 3)

L Rating At Ambient - less than 1 CFM/sq ft

L Rating At 400 F - less than 1 CFM/sq ft

1. Wall Assembly

A. Studs

B. Gypsum Board*

2. Through Penetrant

A. Steel Pipe

B. Iron Pipe

C. Conduit

D. Copper Tubing

E. Copper Pipe

F. Through Penetrating Product* - Flexible Metal Piping

OMEGA FLEX INC

TITEFLEX CORP

A BUNDY CO

WARD MFG INC

3. Fill,Void or Cavity Material* - Caulk or Sealant

HILTI

1. Floor or Wall Assembly

Concrete Blocks*

Concrete Blocks

1A. Steel Sleeve

2. Through Penetrant

A. Steel Pipe

A1. Iron Pipe

B. Conduit

C. Conduit

3. Packing Material

4. Fill,Void or Cavity Materials* - Caulk or Sealant

HILTL

System No. C-AJ-1001

June 15, 2005

F Rating - 3 Hr

T Rating - 0 Hr

W Rating - Class I (See Item 4)

PROVIDE NEW 100A BREAKER IN

2MDP-A/B SECTION 3, IN SPARE AS

SHOWN.

2MDPN-A/B

1600A, 65 KAIC

120/208 3Ø 4W

SECTION 1

2MDPN-A/B

1600A, 65 KAIC

120/208 3Ø 4W

SECTION 2

2MDPN-A/B

1600A, 65 KAIC

120/208 3Ø 4W

SECTION 3

NEW PANEL

N-2-G-S-2

100A

4-2 AWG AND 1-8

EG GND IN 1"C.

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

# 2

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

ELECTRICAL DIAGRAMS & DETAILS

MJJ GDA

E-501

10 11

WALL CONDUIT PENETRATION DETAIL

NO SCALE

CEILING/FLOOR CONDUIT PENETRATION DETAIL

NO SCALE

ELECTRICAL DISTRIBUTION INSTALLATION DIAGRAM

NO SCALE

LUMINAIRE MOUNTING - LAY-IN CEILING

NO SCALE

EXIT SIGN MOUNTING - LAY-IN CEILING

NO SCALE

CONDUIT ROOF PENETRATION DETAIL

NO SCALE

ROOF CONDUIT SUPPORT DETAIL

NO SCALE

RECEPTACLE ROOF MOUTING DETAIL

NO SCALE

Revisions: Date

Drawing Title:

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

Office of

Construction and Facilities

Management

CONSULTANTS: PROJECT MANAGER:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120

Cary, North Carolina 27511 www.acg-pa.com 919-858-7420

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

# 2

502-16-104

TAMEKA J. TAYLOR

1-9-2020

100% CONSTRUCTION DOCUMENTS

17-108

2495 SHREVEPORT HWY. PINEVILLE, LA 71360

REPLACE HVAC SYSTEM

& PANEL SCHEDULES

MECHANICAL EQUIPMENT CONNECTION

MJJ GDA

E-601

11 11

MECHANICAL EQUIPMENT CONNECTION SCHEDULE

TAG DESCRIPTION VOLTS PHASE LOAD MOCP

2-FCU-01

CONDUCTORS NEUTRAL GROUND CONDUIT DISCONNECT TYPE

2- FAN COIL UNIT-01 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-02 2- FAN COIL UNIT-02 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-03 2- FAN COIL UNIT-03 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-04 2- FAN COIL UNIT-04 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-05 2- FAN COIL UNIT-05 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-06 2- FAN COIL UNIT-06 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-07A 2- FAN COIL UNIT-07A 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-07B 2- FAN COIL UNIT-07B 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-08 2- FAN COIL UNIT-08 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-09 2- FAN COIL UNIT-09 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-10A 2- FAN COIL UNIT-10A 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-10B 2- FAN COIL UNIT-10B 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-10C 2- FAN COIL UNIT-10C 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-11 2- FAN COIL UNIT-11 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-11A 2- FAN COIL UNIT-11A 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-11B 2- FAN COIL UNIT-11B 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-11C 2- FAN COIL UNIT-11C 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-11D 2- FAN COIL UNIT-11D 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-11E 2- FAN COIL UNIT-11E 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-11F 2- FAN COIL UNIT-11F 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-11G 2- FAN COIL UNIT-11G 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-11H 2- FAN COIL UNIT-11H 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-13A 2- FAN COIL UNIT-13A 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-13B 2- FAN COIL UNIT-13B 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-14 2- FAN COIL UNIT-14 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-15 2- FAN COIL UNIT-15 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-16 2- FAN COIL UNIT-16 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-17 2- FAN COIL UNIT-17 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-18 2- FAN COIL UNIT-18 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-19 2- FAN COIL UNIT-19 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-20 2- FAN COIL UNIT-20 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-21 2- FAN COIL UNIT-21 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-22 2- FAN COIL UNIT-22 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-23 2- FAN COIL UNIT-23 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-24 2- FAN COIL UNIT-24 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-25 2- FAN COIL UNIT-25 120 1 0.51 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-26 2- FAN COIL UNIT-26 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-27 2- FAN COIL UNIT-27 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-28 2- FAN COIL UNIT-28 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-29 2- FAN COIL UNIT-29 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-30 2- FAN COIL UNIT-30 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-31 2- FAN COIL UNIT-31 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-32 2- FAN COIL UNIT-32 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-33 2- FAN COIL UNIT-33 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-34 2- FAN COIL UNIT-34 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-35 2- FAN COIL UNIT-35 120 1 0.29 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-36 2- FAN COIL UNIT-36 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-37 2- FAN COIL UNIT-37 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-38 2- FAN COIL UNIT-38 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-39 2- FAN COIL UNIT-39 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-40 2- FAN COIL UNIT-40 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-41 2- FAN COIL UNIT-41 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-42 2- FAN COIL UNIT-42 120 1 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-43 2- FAN COIL UNIT-43 120 1 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-44 2- FAN COIL UNIT-44 120 1 0.51 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-45 2- FAN COIL UNIT-45 120 1 0.22 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-46 2- FAN COIL UNIT-46 120 1 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-47 2- FAN COIL UNIT-47 120 1 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-FCU-48 2- FAN COIL UNIT-48 120 1 0.46 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-CWP-1 208 3 6 AWG3 1"

2-CWP-2 208 3 6 AWG3 1"

2-CWP-3 208 3 6 AWG3 1"

2-CWP-4 2-COLD WATER PUMP-4 208 3 17.4 kVA 6 AWG3 1"

2-ERV-1 208 3 8 AWG3 3/4"

2-ERV-2

2-ENERGY RECOVERY

UNIT-2

208 3 13.5 kVA 8 AWG3 3/4"

2-AH-2 208 3 3P-70A 6 AWG3 1"

2-AH-2(UV)

120 1 1P-15A 12 AWG1 12 AWG 12 AWG 3/4"

2-AH-2(REC)

120 1 1P-15A 12 AWG1 12 AWG 12 AWG 3/4"

2-AH-1 2-AIR HANDLER-1 208 3 18.9 kVA 3P-70A 6 AWG3 1" 100F/70A/3P 250V N1 SAFETY DISCONNECT SWITCH

2-AH-1(UV)

2-UV LIGHTS-1 120 1 0.19 kVA 1P-15A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

2-AH-1(REC)

2-RECEPTACLE-1 120 1 0.96 kVA 1P-15A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

3P-50A

3P-50A

3P-60A

3P-60A

3P-60A

3P-60A

2-AIR HANDLER-2

2-UV LIGHTS-2

2-RECEPTACLE-2

2-ENERGY RECOVERY

UNIT-1

2-COLD WATER PUMP-3

2-COLD WATER PUMP-2

2-COLD WATER PUMP-1

100F/70A/3P 250V N3R SAFETY DISCONNECT SWITCH

60F/50A/3P 250V N3R SAFETY DISCONNECT SWITCH

60F/50A/3P 250V N3R SAFETY DISCONNECT SWITCH

60F/50A/3P 250V N3R SAFETY DISCONNECT SWITCH

30F/15A/1P 250V N3R SAFETY DISCONNECT SWITCH

30F/15A/1P 250V N3R SAFETY DISCONNECT SWITCH

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

8 AWG

10 AWG

10 AWG

18.9 kVA

0.19 kVA

0.96 kVA

13.5 kVA

17.4 kVA

17.4 kVA

17.4 kVA

0.46 kVA

0.46 kVA

0.51 kVA

0.46 kVA

MECHANICAL EQUIPMENT CONNECTION SCHEDULE

NO SCALE

2-FCU-49 2- FAN COIL UNIT-49 120 1 0.46 kVA 1P-20A 12 AWG1 12 AWG 12 AWG 3/4" 1P-20A 125V MOTOR RATED SWITCH

60F/50A/3P 250V N3R SAFETY DISCONNECT SWITCH

60F/50A/3P 250V N3R SAFETY DISCONNECT SWITCH

60F/50A/3P 250V N3R SAFETY DISCONNECT SWITCH

E-001-GENERAL NOTES LEGEND AND ABBREVIATIONS
Sheets and Views
GENERAL NOTES LEGEND AND ABBREVIATIONS
ED101-ELECTRICAL DEMOLITION PLAN - BASEMENT
Sheets and Views
ELECTRICAL DEMOLITION PLAN - BASEMENT
ED102-ELECTRICAL DEMOLITION PLAN - 1ST FLOOR
Sheets and Views
ELECTRICAL DEMOLITION PLAN - 1ST FLOOR
ED103-ELECTRICAL DEMOLITION PLAN - ATTIC AND ROOF
Sheets and Views
ELECTRICAL DEMOLITION PLAN - ATTIC AND ROOF
ED104-ELECTRICAL DEMOLITION PLAN - ATTIC AND ROOF
Sheets and Views
ELECTRICAL DEMOLITION PLAN - ATTIC AND ROOF
EL-101-ELECTRICAL NEW WORK PLAN - 1ST FLOOR
Sheets and Views
ELECTRICAL NEW WORK PLAN - 1ST FLOOR
E-101-ELECTRICAL NEW WORK PLAN - BASEMENT
Sheets and Views
ELECTRICAL NEW WORK PLAN - BASEMENT
E-102-ELECTRICAL NEW WORK PLAN - 1ST FLOOR
Sheets and Views
ELECTRICAL NEW WORK PLAN - 1ST FLOOR
E-103-ELECTRICAL NEW WORK PLAN - ROOF
Sheets and Views
ELECTRICAL NEW WORK PLAN - ROOF
E-501-ELECTRICAL DETAILS
Sheets and Views
ELECTRICAL DETAILS
E-601-ELECTRICAL DETAILS
Sheets and Views
ELECTRICAL DETAILS
2020-01-08T12:52:55-0800
Digitally verifiable PDF exported from www.docusign.com

File details come from the government source that posted it. Updated .