5-Scedule II -Montgomery Helioscopes Combined.pdf

PDF 7 MB Posted

Attached to
Solar Procurement and Installation for projects identified by the Sustainable Energy Partnership (“SEP”)
Solicitation number
6599
Issued by
Montgomery County, Pennsylvania

About this file

This document contains solar system performance reports prepared by the Pennsylvania Solar Center using Aurora Solar simulation software for multiple solar photovoltaic projects identified by the Sustainable Energy Partnership (SEP), a consortium comprising Bucks County, Chester County, Delaware County, and Montgomery County in Pennsylvania. The reports present detailed technical analyses and annual energy production projections for eight distinct solar installations across the Montgomery County region, including systems at the Fire Academy (540 Port Indian Rd, Eagleville, PA), Youth Center (60 Eagleville Rd, Eagleville, PA), Trail Center (75 East Lafayette St., Norristown, PA), and Courthouse Annex (102 N York Rd, Willow Grove, PA). Each project includes comparative analyses between two system configurations: one utilizing Enphase microinverters and one utilizing SolarEdge string inverters with power optimizers. The projects range in scale from 22.82 kW to 1.78 MW DC nameplate capacity, with annual production estimates ranging from approximately 29.3 MWh to 2.375 GWh. The simulation reports employ standardized weather data from the National Renewable Energy Laboratory (NREL) for the region at coordinates 40.15, -75.35, with consistent assumptions regarding soiling rates, albedo, module characteristics, and system losses applied across all analyses.

The reports detail comprehensive system metrics including performance ratios ranging from 75.8 percent to 84.6 percent, module specifications utilizing QCELLS Q.PEAK DUO bifacial solar modules rated at 485 watts or 585 watts, and inverter options from Enphase and SolarEdge manufacturers. Each analysis quantifies system losses across multiple categories including front shading (1.0 to 5.4 percent), reflection (3.0 to 3.6 percent), soiling (4.9 to 5.2 percent), temperature derating (2.0 to 6.8 percent), and inverter losses (1.5 to 3.5 percent). The documents provide detailed field segment layouts specifying racking configurations, tilt angles, azimuth orientations, module counts, and power ratings for each installation. All simulations were conducted using identical meteorological conditions and thermal modeling parameters, establishing a standardized baseline for comparing system performance between different inverter architectures and configurations across the SEP counties' solar procurement initiative.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MontCo - Fire Academy Enphase - Montgomery, 540 Port Indian Rd, Eagleville, PA 19403

Project Name Montgomery

Project

Address

540 Port Indian Rd, Eagleville, PA

19403

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design MontCo - Fire Academy Enphase

Module DC

Nameplate

127.07 kW

Inverter AC

Nameplate

111.87 kW

Load Ratio: 1.14

Annual Production 168.8 MWh

Performance Ratio 83.9% kWh/kWp 1,328.7

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version 7cc42bb06c-14b3484bd1-

9cccf5a138-0f50ce10e4

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

10k

20k

30k

Sources of System Loss

Front ShadingFront Shading: 2.2%: 2.2%Front Shading: 2.2%

ReflectionReflection: 3.3%: 3.3%Reflection: 3.3%

SoilingSoiling: 5.0%: 5.0%Soiling: 5.0% IrradianceIrradiance: 0.7%: 0.7%Irradiance: 0.7%

TemperatureTemperature: 2.0%: 2.0%Temperature: 2.0%

ElectricalElectrical MismatchMismatch: 0.1%: 0.1% Electrical Mismatch: 0.1%

WiringWiring: 0.1%: 0.1%Wiring: 0.1%

ClippingClipping: 0.9%: 0.9%Clipping: 0.9%

InvertersInverters: 2.9%: 2.9%Inverters: 2.9%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

BifacialityBifaciality: 0.1%: 0.1%Bifaciality: 0.1%

Annual Production Report produced by Pennsylvania Solar Center

© 2026 Aurora Solar 1 / 4 April 20, 2026

Description Output

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal

Irradiance 1,476.0

POA Irradiance 1,583.2 7.3%

Shaded Irradiance 1,548.7 -2.2%

Irradiance after Reflection 1,497.7 -3.3%

Irradiance after Soiling 1,422.4 -5.0%

Total Front Collector Irradiance 1,422.4 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on

Surface

437.2 -

Surface Reflected

Irradiance after

Albedo

87.4 -80.0%

Conversion from

Surface Area to

Collector Area

124.3

Surface Irradiance in Collector Plane

5.6 -95.5%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in Collector Plane 5.6

Sky Diffuse 1.6

Beam Effective 0.0

Total Unshaded

Irradiance on Rear

Side

7.2

Shaded Irradiance on Rear Side 6.9 -5.0%

Total Rear Collector Irradiance 6.9

Effective Rear Collector

Irradiance

4.8 -30.0%

Total Collector Irradiance 1,427.2

Energy

(kWh)

Nameplate 181,370.9

Output at Irradiance Levels 180,067.7 -0.7%

Output at Cell Temperature Derate 176,499.3 -2.0%

Output after Electrical Mismatch 176,361.6 -0.1%

Output after Rear Mismatch 176,302.5 0.0%

Optimal DC Output 176,239.8 -0.1%

Constrained DC Output 174,710.4 -0.9%

Inverter Output 169,680.8 -2.9%

Energy to Grid 168,832.4 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 22.0 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature

Model Sandia Model

Temperature

Model Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation

Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module Q.PEAK DUO XL-G10.d/BFG

485W (QCELLS)

Spec Sheet

Characterization, PAN True

Inverter

IQ9N-3P-A-US-277 (2026)

(Enphase) Default Characterization N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

© 2026 Aurora Solar 2 / 4 April 20, 2026 https://app.helioscope.com/library/meteo/6111

Component Name Count

Inverters

IQ9N-3P-A-US-277 (2026)

(Enphase)

(111.87 kW)

Strings 10 AWG (Copper) 262 (705.3 ft)

Module

QCELLS, Q.PEAK DUO XL-

G10.d/BFG 485W (485W)

(127.07 kW)

Components

Description Combiner Poles String Size Stringing Strategy

Wiring Zone - 1-1 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field

Segment 1

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

154.03525°

1.5 ft 1x1 52 52

25.22 kW

Field

Segment 2

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

154.03525°

1.5 ft 1x1 67 67

32.50 kW

Field

Segment 3

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

154.03525°

1.5 ft 1x1 53 53

25.71 kW

Field

Segment 4

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

154.03525°

1.5 ft 1x1 90 90

43.65 kW

Field Segments

© 2026 Aurora Solar 3 / 4 April 20, 2026

Detailed Layout2

© 2026 Aurora Solar 4 / 4 April 20, 2026

MontCo - Fire Academy String - Montgomery, 540 Port Indian Rd, Eagleville, PA

19403

Project Name Montgomery

Project

Address

540 Port Indian Rd, Eagleville, PA

19403

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design MontCo - Fire Academy String

Module DC

Nameplate

127.07 kW

Inverter AC

Nameplate

133.20 kW

Load Ratio: 0.95

Annual Production 169.1 MWh

Performance Ratio 84.1% kWh/kWp 1,330.7

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version 68034364bf-a0135c5470-

972ff57921-bdb00e3c98

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

10k

20k

30k

Sources of System Loss

Front ShadingFront Shading: 2.2%: 2.2%Front Shading: 2.2%

ReflectionReflection: 3.3%: 3.3%Reflection: 3.3%

SoilingSoiling: 5.0%: 5.0%Soiling: 5.0% IrradianceIrradiance: 0.7%: 0.7%Irradiance: 0.7%

TemperatureTemperature: 2.0%: 2.0%Temperature: 2.0%

ElectricalElectrical MismatchMismatch: 0.5%: 0.5% Electrical Mismatch: 0.5%

OptimizersOptimizers: 1.2%: 1.2%Optimizers: 1.2%

WiringWiring: 0.4%: 0.4%Wiring: 0.4%

InvertersInverters: 1.5%: 1.5%Inverters: 1.5%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

BifacialityBifaciality: 0.1%: 0.1%Bifaciality: 0.1%

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal

Irradiance 1,476.0

POA Irradiance 1,583.2 7.3%

Shaded Irradiance 1,548.7 -2.2%

Irradiance after Reflection 1,497.7 -3.3%

Irradiance after Soiling 1,422.4 -5.0%

Total Front Collector Irradiance 1,422.4 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on

Surface

437.2 -

Surface Reflected

Irradiance after

Albedo

87.4 -80.0%

Conversion from

Surface Area to

Collector Area

124.3

Surface Irradiance in Collector Plane

5.6 -95.5%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in Collector Plane 5.6

Sky Diffuse 1.6

Beam Effective 0.0

Total Unshaded

Irradiance on Rear

Side

7.2

Shaded Irradiance on Rear Side 6.9 -5.1%

Total Rear Collector Irradiance 6.9

Effective Rear Collector

Irradiance

4.8 -30.0%

Total Collector Irradiance 1,427.2

Energy

(kWh)

Nameplate 181,363.0

Output at Irradiance Levels 180,059.9 -0.7%

Output at Cell Temperature Derate 176,491.7 -2.0%

Output after Electrical Mismatch 175,691.4 -0.5%

Output after Rear Mismatch 175,632.6 0.0%

Optimizer Output 173,521.1 -1.2%

Optimal DC Output 172,752.1 -0.4%

Constrained DC Output 172,534.5 -0.1%

Inverter Output 169,946.5 -1.5%

Energy to Grid 169,096.8 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 22.0 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature

Model Sandia Model

Temperature

Model Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation

Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module Q.PEAK DUO XL-G10.d/BFG

485W (QCELLS)

Spec Sheet

Characterization, PAN True

Inverter SE66.6KUS (SolarEdge) Spec Sheet N/A

Buck Boost

Optimizer S1200 (SolarEdge) Mfg Spec Sheet N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

Inverters SE66.6KUS (SolarEdge) 2 (133.20 kW)

Strings 10 AWG (Copper) 8 (1,375.7 ft)

Optimizers S1200 (SolarEdge) 134 (160.80 kW)

Module

QCELLS, Q.PEAK DUO XL-

G10.d/BFG 485W (485W)

262 (127.07 kW)

Components

Description Combiner Poles String Size Stringing Strategy

Wiring Zone - 13-35 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field

Segment 1

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

154.03525°

1.5 ft 1x1 52 52

25.22 kW

Field

Segment 2

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

154.03525°

1.5 ft 1x1 67 67

32.50 kW

Field

Segment 3

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

154.03525°

1.5 ft 1x1 53 53

25.71 kW

Field

Segment 4

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

154.03525°

1.5 ft 1x1 90 90

43.65 kW

Field Segments

MontCo - Youth Center Enphase - Montgomery, 540 Port Indian Rd, Eagleville, PA 19403

Project Name Montgomery

Project

Address

540 Port Indian Rd, Eagleville, PA

19403

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design MontCo - Youth Center Enphase

Module DC

Nameplate

350.17 kW

Inverter AC

Nameplate

308.29 kW

Load Ratio: 1.14

Annual

Production

436.2 MWh

Performance

Ratio 80.7% kWh/kWp 1,245.6

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version 7478cad220-d9da36e9eb-

649e91004b-10da27cc5d

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

20k

40k

60k

Sources of System Loss

Front ShadingFront Shading: 1.0%: 1.0%Front Shading: 1.0%

ReflectionReflection: 3.6%: 3.6%Reflection: 3.6%

SoilingSoiling: 4.9%: 4.9%Soiling: 4.9%

IrradianceIrradiance: 0.7%: 0.7%Irradiance: 0.7%

TemperatureTemperature: 6.8%: 6.8%Temperature: 6.8%

ElectricalElectrical MismatchMismatch: 0.1%: 0.1% Electrical Mismatch: 0.1%

WiringWiring: 0.1%: 0.1%Wiring: 0.1%

ClippingClipping: 0.3%: 0.3%Clipping: 0.3%

InvertersInverters: 2.9%: 2.9%Inverters: 2.9%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

BifacialityBifaciality: 0.0%: 0.0%Bifaciality: 0.0%

© 2026 Aurora Solar 1 / 4 April 21, 2026

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal

Irradiance 1,476.0

POA Irradiance 1,542.9 4.5%

Shaded Irradiance 1,527.2 -1.0%

Irradiance after Reflection 1,472.0 -3.6%

Irradiance after Soiling 1,399.2 -4.9%

Total Front Collector Irradiance 1,399.1 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on

Surface

20.4 -

Surface Reflected

Irradiance after

Albedo

4.1 -80.0%

Conversion from

Surface Area to

Collector Area

6.0

Surface Irradiance in Collector Plane

0.3 -95.7%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in Collector Plane 0.3

Sky Diffuse 0.1

Beam Effective 0.0

Total Unshaded

Irradiance on Rear

Side

0.4

Shaded Irradiance on Rear Side 0.3 -5.1%

Total Rear Collector Irradiance 0.3

Effective Rear Collector

Irradiance

0.2 -30.0%

Total Collector Irradiance 1,399.4

Energy

(kWh)

Nameplate 490,078.2

Output at Irradiance Levels 486,418.7 -0.7%

Output at Cell Temperature Derate 453,484.8 -6.8%

Output after Electrical Mismatch 453,136.6 -0.1%

Output after Rear Mismatch 453,129.0 0.0%

Optimal DC Output 452,841.6 -0.1%

Constrained DC Output 451,375.5 -0.3%

Inverter Output 438,366.7 -2.9%

Energy to Grid 436,174.9 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 29.2 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature

Model Sandia Model

Temperature

Model Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation

Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module Q.PEAK DUO XL-G10.d/BFG

485W (QCELLS)

Spec Sheet

Characterization, PAN True

Inverter

IQ9N-3P-A-US-277 (2026)

(Enphase) Default Characterization N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

© 2026 Aurora Solar 2 / 4 April 21, 2026

IQ9N-3P-A-US-277 (2026)

(Enphase)

722 (308.29 kW)

Strings 10 AWG (Copper)

(3,272.8 ft)

Module

QCELLS, Q.PEAK DUO XL-

G10.d/BFG 485W (485W)

722 (350.17 kW)

Components

Description Combiner Poles String Size Stringing Strategy

Wiring Zone - 1-1 Along Racking

Wiring Zone 2 - 1-1 Along Racking

Wiring Zone 3 - 1-1 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field

Segment 1

Flush

Mount

Landscape

(Horizontal) 12° 69° 0.1 ft 1x1 71 71

34.44 kW

Field

Segment 2

Flush

Mount

Landscape

(Horizontal) 12° 158.1819° 0.1 ft 1x1 58 58

28.13 kW

Field

Segment 3

Flush

Mount

Landscape

(Horizontal) 12° 158.3404° 0.1 ft 1x1 185 185

89.73 kW

Field

Segment 4

Flush

Mount

Landscape

(Horizontal) 12° 68.154594° 0.1 ft 1x1 135 135

65.48 kW

Field

Segment 5

Flush

Mount

Landscape

(Horizontal) 10° 157.8452° 0.1 ft 1x1 61 61

29.59 kW

Field

Segment 6

Flush

Mount

Landscape

(Horizontal) 10° 157.8452° 0.1 ft 1x1 55 55

26.68 kW

Field

Segment 7

Flush

Mount

Landscape

(Horizontal) 10° 158.46954° 0.1 ft 1x1 63 63

30.56 kW

Field

Segment 8

Flush

Mount

Landscape

(Horizontal) 10° 157.84369° 0.1 ft 1x1 63 63

30.56 kW

Field

Segment 9 Fixed Tilt

Landscape

(Horizontal)

Module:

10°

Module:

157.84369°

1.7 ft 1x1 9 9

4.37 kW

Field

Segment 10 Fixed Tilt

Landscape

(Horizontal)

Module:

10°

Module:

157.84369°

1.7 ft 1x1 16 16

7.76 kW

Field

Segment 11 Fixed Tilt

Landscape

(Horizontal)

Module:

10°

Module:

157.84369°

1.7 ft 1x1 6 6

2.91 kW

Field Segments

© 2026 Aurora Solar 3 / 4 April 21, 2026

© 2026 Aurora Solar 4 / 4 April 21, 2026

MontCo - Youth Center String - Montgomery, 540 Port Indian Rd, Eagleville, PA

19403

Project Name Montgomery

Project

Address

540 Port Indian Rd, Eagleville, PA

19403

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design MontCo - Youth Center String

Module DC

Nameplate

350.17 kW

Inverter AC

Nameplate

399.60 kW

Load Ratio: 0.88

Annual

Production

435.8 MWh

Performance

Ratio 80.7% kWh/kWp 1,244.6

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version 7478cad220-d9da36e9eb-

649e91004b-10da27cc5d

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

20k

40k

60k

Sources of System Loss

Front ShadingFront Shading: 1.0%: 1.0%Front Shading: 1.0%

ReflectionReflection: 3.6%: 3.6%Reflection: 3.6%

SoilingSoiling: 4.9%: 4.9%Soiling: 4.9%

IrradianceIrradiance: 0.7%: 0.7%Irradiance: 0.7%

TemperatureTemperature: 6.8%: 6.8%Temperature: 6.8%

ElectricalElectrical MismatchMismatch: 0.3%: 0.3% Electrical Mismatch: 0.3%

OptimizersOptimizers: 1.2%: 1.2%Optimizers: 1.2%

WiringWiring: 0.3%: 0.3%Wiring: 0.3%

ClippingClipping: 0.1%: 0.1%Clipping: 0.1%

InvertersInverters: 1.5%: 1.5%Inverters: 1.5%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal

Irradiance 1,476.0

POA Irradiance 1,542.9 4.5%

Shaded Irradiance 1,527.2 -1.0%

Irradiance after Reflection 1,472.0 -3.6%

Irradiance after Soiling 1,399.2 -4.9%

Total Front Collector Irradiance 1,399.1 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on

Surface

20.4 -

Surface Reflected

Irradiance after

Albedo

4.1 -80.0%

Conversion from

Surface Area to

Collector Area

6.0

Surface Irradiance in Collector Plane

0.3 -95.7%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in Collector Plane 0.3

Sky Diffuse 0.1

Beam Effective 0.0

Total Unshaded

Irradiance on Rear

Side

0.4

Shaded Irradiance on Rear Side 0.3 -10.0%

Total Rear Collector Irradiance 0.3

Effective Rear Collector

Irradiance

0.2 -30.0%

Total Collector Irradiance 1,399.3

Energy

(kWh)

Nameplate 490,070.5

Output at Irradiance Levels 486,411.1 -0.7%

Output at Cell Temperature Derate 453,384.5 -6.8%

Output after Electrical Mismatch 452,029.0 -0.3%

Output after Rear Mismatch 452,021.7 0.0%

Optimizer Output 446,586.8 -1.2%

Optimal DC Output 445,051.8 -0.3%

Constrained DC Output 444,679.5 -0.1%

Inverter Output 438,009.3 -1.5%

Energy to Grid 435,819.3 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 29.2 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature

Model Sandia Model

Temperature

Model Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation

Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module Q.PEAK DUO XL-G10.d/BFG

485W (QCELLS)

Spec Sheet

Characterization, PAN True

Inverter SE66.6KUS (SolarEdge) Spec Sheet N/A

Buck Boost

Optimizer S1200 (SolarEdge) Mfg Spec Sheet N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

Inverters SE66.6KUS (SolarEdge) 6 (399.60 kW)

Strings 10 AWG (Copper) 23 (2,807.1 ft)

Optimizers S1200 (SolarEdge) 368 (441.60 kW)

Module

QCELLS, Q.PEAK DUO XL-

G10.d/BFG 485W (485W)

722 (350.17 kW)

Components

Description Combiner Poles String Size Stringing Strategy

Wiring Zone - 13-35 Along Racking

Wiring Zone 2 - 13-35 Along Racking

Wiring Zone 3 - 13-35 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field

Segment 1

Flush

Mount

Landscape

(Horizontal) 12° 69° 0.1 ft 1x1 71 71

34.44 kW

Field

Segment 2

Flush

Mount

Landscape

(Horizontal) 12° 158.1819° 0.1 ft 1x1 58 58

28.13 kW

Field

Segment 3

Flush

Mount

Landscape

(Horizontal) 12° 158.3404° 0.1 ft 1x1 185 185

89.73 kW

Field

Segment 4

Flush

Mount

Landscape

(Horizontal) 12° 68.154594° 0.1 ft 1x1 135 135

65.48 kW

Field

Segment 5

Flush

Mount

Landscape

(Horizontal) 10° 157.8452° 0.1 ft 1x1 61 61

29.59 kW

Field

Segment 6

Flush

Mount

Landscape

(Horizontal) 10° 157.8452° 0.1 ft 1x1 55 55

26.68 kW

Field

Segment 7

Flush

Mount

Landscape

(Horizontal) 10° 158.46954° 0.1 ft 1x1 63 63

30.56 kW

Field

Segment 8

Flush

Mount

Landscape

(Horizontal) 10° 157.84369° 0.1 ft 1x1 63 63

30.56 kW

Field

Segment 9 Fixed Tilt

Landscape

(Horizontal)

Module:

10°

Module:

157.84369°

1.7 ft 1x1 9 9

4.37 kW

Field

Segment 10 Fixed Tilt

Landscape

(Horizontal)

Module:

10°

Module:

157.84369°

1.7 ft 1x1 16 16

7.76 kW

Field

Segment 11 Fixed Tilt

Landscape

(Horizontal)

Module:

10°

Module:

157.84369°

1.7 ft 1x1 6 6

2.91 kW

Field Segments

MontCo - Trail Center Enphase IQ8 - Montgomery, 75 East Lafayette St., Norristown, PA

Project Name Montgomery

Project Address 75 East Lafayette St., Norristown, PA

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design MontCo - Trail Center Enphase IQ8

Module DC

Nameplate

22.82 kW

Inverter AC

Nameplate

18.53 kW

Load Ratio: 1.23

Annual Production 30.67 MWh

Performance Ratio 85.0% kWh/kWp 1,344.2

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version d41bb4f217-702647e35c-

25cbfbd28d-1d4a14f0cf

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

1k

2k

3k

4k

Sources of System Loss

Front ShadingFront Shading: 1.1%: 1.1%Front Shading: 1.1%

ReflectionReflection: 3.5%: 3.5%Reflection: 3.5%

SoilingSoiling: 5.0%: 5.0%Soiling: 5.0%IrradianceIrradiance: 0.8%: 0.8%Irradiance: 0.8%

TemperatureTemperature: 2.0%: 2.0%Temperature: 2.0%

ElectricalElectrical MismatchMismatch: 0.1%: 0.1% Electrical Mismatch: 0.1%

WiringWiring: 0.1%: 0.1%Wiring: 0.1%

ClippingClipping: 0.6%: 0.6%Clipping: 0.6%

InvertersInverters: 2.7%: 2.7%Inverters: 2.7%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

BifacialityBifaciality: 0.1%: 0.1%Bifaciality: 0.1%

Rear MismatchRear Mismatch: 0.0%: 0.0%Rear Mismatch: 0.0%

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal Irradiance 1,476.0

POA Irradiance 1,581.2 7.1%

Shaded Irradiance 1,564.5 -1.1%

Irradiance after Reflection 1,510.0 -3.5%

Irradiance after Soiling 1,433.8 -5.0%

Total Front Collector Irradiance 1,433.8 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on Surface

510.3 -

Surface Reflected

Irradiance after

Albedo

102.1 -80.0%

Conversion from

Surface Area to

Collector Area

141.6

Surface Irradiance in Collector Plane

5.4 -96.2%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in

Collector Plane 5.4

Sky Diffuse 1.7

Beam Effective 0.0

Total Unshaded

Irradiance on Rear

Side

7.1

Shaded Irradiance on Rear Side 6.7 -5.0%

Total Rear Collector Irradiance 6.7

Effective Rear Collector

Irradiance

4.7 -30.0%

Total Collector Irradiance 1,438.5

Energy

(kWh)

Nameplate 32,812.9

Output at Irradiance Levels 32,561.2 -0.8%

Output at Cell Temperature Derate 31,907.2 -2.0%

Output after Electrical Mismatch 31,886.4 -0.1%

Output after Rear Mismatch 31,875.9 0.0%

Optimal DC Output 31,861.6 -0.1%

Constrained DC Output 31,685.4 -0.6%

Inverter Output 30,822.0 -2.7%

Energy to Grid 30,667.9 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 22.0 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature

Model Sandia Model

Temperature

Model Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation

Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module

Q.PEAK DUO XL-G11S 585W

(QCells)

Spec Sheet Characterization, PAN

True

Inverter

IQ8P-3P-72-E-US-208 (2026)

(Enphase) Default Characterization N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

IQ8P-3P-72-E-US-208 (2026)

(Enphase)

39 (18.53 kW)

Strings 10 AWG (Copper) 39 (110.2 ft)

Module QCells, Q.PEAK DUO XL-G11S

585W (585W)

39 (22.82 kW)

Components

Description Combiner Poles String Size Stringing Strategy

Wiring Zone - 1-1 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field

Segment 1

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

206.01668°

1.5 ft 1x1 39 39

22.82 kW

Field Segments

MontCo - Trail Center String - Montgomery, 75 East Lafayette St., Norristown, PA

Project Name Montgomery

Project Address 75 East Lafayette St., Norristown, PA

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design MontCo - Trail Center String

Module DC

Nameplate

22.82 kW

Inverter AC

Nameplate

25.00 kW

Load Ratio: 0.91

Annual Production 29.29 MWh

Performance Ratio 81.2% kWh/kWp 1,283.8

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version 68034364bf-a0135c5470-

972ff57921-bdb00e3c98

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

1k

2k

3k

4k

Sources of System Loss

Front ShadingFront Shading: 1.1%: 1.1%Front Shading: 1.1%

ReflectionReflection: 3.5%: 3.5%Reflection: 3.5%

SoilingSoiling: 5.0%: 5.0%Soiling: 5.0%

IrradianceIrradiance: 0.8%: 0.8%Irradiance: 0.8%TemperatureTemperature: 2.0%: 2.0%Temperature: 2.0%

ElectricalElectrical MismatchMismatch: 4.0%: 4.0% Electrical Mismatch: 4.0%

WiringWiring: 0.4%: 0.4%Wiring: 0.4%

ClippingClipping: 0.0%: 0.0%Clipping: 0.0%

InvertersInverters: 3.5%: 3.5%Inverters: 3.5%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

BifacialityBifaciality: 0.1%: 0.1%Bifaciality: 0.1%

Rear MismatchRear Mismatch: 0.0%: 0.0%Rear Mismatch: 0.0%

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal Irradiance 1,476.0

POA Irradiance 1,581.2 7.1%

Shaded Irradiance 1,564.5 -1.1%

Irradiance after Reflection 1,510.0 -3.5%

Irradiance after Soiling 1,433.8 -5.0%

Total Front Collector Irradiance 1,433.9 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on Surface

510.3 -

Surface Reflected

Irradiance after

Albedo

102.1 -80.0%

Conversion from

Surface Area to

Collector Area

141.6

Surface Irradiance in Collector Plane

5.4 -96.2%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in

Collector Plane 5.4

Sky Diffuse 1.7

Beam Effective 0.0

Total Unshaded

Irradiance on Rear

Side

7.1

Shaded Irradiance on Rear Side 6.7 -5.2%

Total Rear Collector Irradiance 6.7

Effective Rear Collector

Irradiance

4.7 -30.0%

Total Collector Irradiance 1,438.6

Energy

(kWh)

Nameplate 32,822.3

Output at Irradiance Levels 32,570.4 -0.8%

Output at Cell Temperature Derate 31,915.9 -2.0%

Output after Electrical Mismatch 30,630.8 -4.0%

Output after Rear Mismatch 30,620.8 0.0%

Optimal DC Output 30,520.6 -0.4%

Constrained DC Output 30,512.1 0.0%

Inverter Output 29,436.7 -3.6%

Energy to Grid 29,289.5 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 22.0 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature

Model Sandia Model

Temperature

Model Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation

Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module

Q.PEAK DUO XL-G11S 585W

(QCells)

Spec Sheet

Characterization, PAN True

Inverter CPS SCA25KTL-DO/US-208 (Chint

Power Systems) Default Characterization N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

CPS SCA25KTL-DO/US-208

(Chint Power Systems)

1 (25.00 kW)

Strings 10 AWG (Copper) 3 (219.7 ft)

Module QCells, Q.PEAK DUO XL-G11S

585W (585W)

39 (22.82 kW)

Components

Description Combiner Poles String Size Stringing Strategy

Wiring Zone - 5-16 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field

Segment 1

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

206.01668°

1.5 ft 1x1 39 39

22.82 kW

Field Segments

MontCo - Courthouse Annex Enphase IQ8 - Montgomery, 102 N York Rd, Willow Grove, PA 19090

Project Name Montgomery

Project

Address

102 N York Rd, Willow Grove, PA

19090

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design MontCo - Courthouse Annex

Enphase IQ8

Module DC

Nameplate

39.29 kW

Inverter AC

Nameplate

38.48 kW

Load Ratio: 1.02

Annual Production 52.19 MWh

Performance Ratio 84.6% kWh/kWp 1,328.5

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version d41bb4f217-702647e35c-

25cbfbd28d-1d4a14f0cf

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.5k

5k

7.5k

Sources of System Loss

Front ShadingFront Shading: 2.3%: 2.3%Front Shading: 2.3%

ReflectionReflection: 3.4%: 3.4%Reflection: 3.4%

SoilingSoiling: 5.0%: 5.0%Soiling: 5.0% IrradianceIrradiance: 0.7%: 0.7%Irradiance: 0.7%

TemperatureTemperature: 2.0%: 2.0%Temperature: 2.0%

ElectricalElectrical MismatchMismatch: 0.1%: 0.1% Electrical Mismatch: 0.1%

WiringWiring: 0.1%: 0.1%Wiring: 0.1%

InvertersInverters: 2.7%: 2.7%Inverters: 2.7%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

BifacialityBifaciality: 0.2%: 0.2%Bifaciality: 0.2%

Rear MismatchRear Mismatch: 0.0%: 0.0%Rear Mismatch: 0.0%

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal Irradiance 1,476.0

POA Irradiance 1,570.2 6.4%

Shaded Irradiance 1,534.5 -2.3%

Irradiance after Reflection 1,482.5 -3.4%

Irradiance after Soiling 1,408.3 -5.0%

Total Front Collector Irradiance 1,408.3 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on Surface

447.5 -

Surface Reflected

Irradiance after

Albedo

89.5 -80.0%

Conversion from

Surface Area to

Collector Area

127.3

Surface Irradiance in Collector Plane

5.8 -95.4%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in

Collector Plane 5.8

Sky Diffuse 1.6

Beam Effective 0.1

Total Unshaded

Irradiance on Rear

Side

7.5

Shaded Irradiance on Rear Side 7.1 -5.0%

Total Rear Collector Irradiance 7.1

Effective Rear Collector

Irradiance

5.0 -30.0%

Total Collector Irradiance 1,413.3

Energy

(kWh)

Nameplate 55,527.0

Output at Irradiance Levels 55,119.5 -0.7%

Output at Cell Temperature Derate 54,007.3 -2.0%

Output after Electrical Mismatch 53,964.7 -0.1%

Output after Rear Mismatch 53,945.8 0.0%

Optimal DC Output 53,915.5 -0.1%

Constrained DC Output 53,908.9 0.0%

Inverter Output 52,451.3 -2.7%

Energy to Grid 52,189.0 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 21.9 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature

Model Sandia Model

Temperature

Model Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation

Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module Q.PEAK DUO XL-G10.d/BFG

485W (QCELLS)

Spec Sheet

Characterization, PAN True

Inverter

IQ8P-3P-72-E-US-208 (2026)

(Enphase) Default Characterization N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

IQ8P-3P-72-E-US-208 (2026)

(Enphase)

81 (38.48 kW)

Strings 10 AWG (Copper) 81 (352.8 ft)

Module

QCELLS, Q.PEAK DUO XL-

G10.d/BFG 485W (485W)

81 (39.29 kW)

Components

Description Combiner Poles String Size Stringing Strategy

Wiring Zone - 1-1 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field

Segment 1

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

215.55°

1.5 ft 1x1 81 81

39.29 kW

Field Segments

MontCo - Courthouse Annex String - Montgomery, 102 N York Rd, Willow

Grove, PA 19090

Project Name Montgomery

Project

Address

102 N York Rd, Willow Grove, PA

19090

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design MontCo - Courthouse Annex String

Module DC

Nameplate

39.29 kW

Inverter AC

Nameplate

36.00 kW

Load Ratio: 1.09

Annual

Production

49.08 MWh

Performance

Ratio 79.6% kWh/kWp 1,249.3

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version 7478cad220-d9da36e9eb-

649e91004b-10da27cc5d

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.5k

5k

7.5k

Sources of System Loss

Front ShadingFront Shading: 2.3%: 2.3%Front Shading: 2.3%

ReflectionReflection: 3.4%: 3.4%Reflection: 3.4%

SoilingSoiling: 5.0%: 5.0%Soiling: 5.0%

IrradianceIrradiance: 0.7%: 0.7%Irradiance: 0.7%TemperatureTemperature: 2.0%: 2.0%Temperature: 2.0%

ElectricalElectrical MismatchMismatch: 5.5%: 5.5% Electrical Mismatch: 5.5%

WiringWiring: 0.3%: 0.3%Wiring: 0.3%

ClippingClipping: 0.1%: 0.1%Clipping: 0.1%

InvertersInverters: 2.9%: 2.9%Inverters: 2.9%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

BifacialityBifaciality: 0.2%: 0.2%Bifaciality: 0.2%

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal Irradiance 1,476.0

POA Irradiance 1,570.2 6.4%

Shaded Irradiance 1,534.6 -2.3%

Irradiance after Reflection 1,482.5 -3.4%

Irradiance after Soiling 1,408.3 -5.0%

Total Front Collector Irradiance 1,408.3 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on Surface

447.5 -

Surface Reflected

Irradiance after

Albedo

89.5 -80.0%

Conversion from

Surface Area to

Collector Area

127.3

Surface Irradiance in Collector Plane

5.8 -95.4%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in

Collector Plane 5.8

Sky Diffuse 1.6

Beam Effective 0.1

Total Unshaded

Irradiance on Rear

Side

7.5

Shaded Irradiance on Rear Side 7.1 -5.1%

Total Rear Collector Irradiance 7.1

Effective Rear Collector

Irradiance

5.0 -30.0%

Total Collector Irradiance 1,413.3

Energy

(kWh)

Nameplate 55,526.2

Output at Irradiance Levels 55,118.6 -0.7%

Output at Cell Temperature Derate 54,006.7 -2.0%

Output after Electrical Mismatch 51,034.0 -5.5%

Output after Rear Mismatch 51,016.2 0.0%

Optimal DC Output 50,873.7 -0.3%

Constrained DC Output 50,803.9 -0.1%

Inverter Output 49,324.5 -2.9%

Energy to Grid 49,077.9 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 21.9 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature

Model Sandia Model

Temperature

Model Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation

Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module Q.PEAK DUO XL-G10.d/BFG

485W (QCELLS)

Spec Sheet

Characterization, PAN True

Inverter CPS SCA 36KTL-DO (US) (Chint) Manufacturer N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

Inverters CPS SCA 36KTL-DO (US) (Chint) 1 (36.00 kW)

Strings 10 AWG (Copper) 6 (598.2 ft)

Module

QCELLS, Q.PEAK DUO XL-

G10.d/BFG 485W (485W)

81 (39.29 kW)

Components

Description Combiner Poles String Size Stringing Strategy

Wiring Zone - 13-16 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field

Segment 1

Fixed

Tilt

Landscape

(Horizontal)

Module:

10°

Module:

215.55°

1.5 ft 1x1 81 81

39.29 kW

Field Segments

Montco- Eagleville Campus- Enphase_04212026 - Montgomery, 60

Eagleville Rd, Eagleville, PA 19403

Project Name Montgomery

Project Address 60 Eagleville Rd, Eagleville, PA 19403

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design Montco- Eagleville Campus-

Enphase_04212026

Module DC

Nameplate

1.78 MW

Inverter AC

Nameplate

1.30 MW

Load Ratio: 1.37

Annual

Production

2.375 GWh

Performance

Ratio 79.8% kWh/kWp 1,332.3

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version 8e3cf736c4-9e4df94b8e-

35ab2d83df-34f6b04b77

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

100k

200k

300k

Sources of System Loss

Front ShadingFront Shading: 5.3%: 5.3%Front Shading: 5.3%

ReflectionReflection: 3.0%: 3.0%Reflection: 3.0%

SoilingSoiling: 5.2%: 5.2%Soiling: 5.2%IrradianceIrradiance: 0.7%: 0.7%Irradiance: 0.7%

TemperatureTemperature: 2.6%: 2.6%Temperature: 2.6%

WiringWiring: 0.2%: 0.2%Wiring: 0.2%

ClippingClipping: 3.4%: 3.4%Clipping: 3.4%

InvertersInverters: 3.0%: 3.0%Inverters: 3.0%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

BifacialityBifaciality: 0.8%: 0.8%Bifaciality: 0.8%

Rear MismatchRear Mismatch: 0.2%: 0.2%Rear Mismatch: 0.2%

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal

Irradiance 1,476.0

POA Irradiance 1,669.2 13.1%

Shaded Irradiance 1,580.7 -5.3%

Irradiance after Reflection 1,533.6 -3.0%

Irradiance after Soiling 1,453.9 -5.2%

Total Front Collector

Irradiance 1,453.9 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on

Surface

476.5 -

Surface Reflected

Irradiance after

Albedo

95.3 -80.0%

Conversion from

Surface Area to

Collector Area

157.2

Surface

Irradiance in

Collector Plane

30.8 -80.4%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in Collector Plane 30.8

Sky Diffuse 11.8

Beam Effective 0.2

Total Unshaded

Irradiance on

Rear Side

42.8

Shaded Irradiance on Rear Side 40.7 -5.0%

Total Rear Collector Irradiance 40.7

Effective Rear Collector

Irradiance

28.5 -30.0%

Total Collector Irradiance 1,482.3

Energy

(kWh)

Nameplate 2,641,601.2

Output at Irradiance Levels 2,622,220.7 -0.7%

Output at Cell Temperature

Derate 2,554,845.4 -2.6%

Output after Electrical Mismatch 2,553,213.6 -0.1%

Output after Rear Mismatch 2,548,327.0 -0.2%

Optimal DC Output 2,547,769.8 -0.2%

Constrained DC Output 2,459,987.5 -3.4%

Inverter Output 2,386,701.8 -3.0%

Energy to Grid 2,374,768.4 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 23.0 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature Model Sandia Model

Temperature Model

Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module

Q.PEAK DUO XL-G11S 585W

(QCells)

Spec Sheet Characterization, PAN

True

Inverter

IQ9N-3P-A-US-277 (2026)

(Enphase) Default Characterization N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

IQ9N-3P-A-US-277 (2026)

(Enphase)

3,047 (1.30

MW)

Strings 10 AWG (Copper) 3,047

(3,990.4 ft)

Module QCells, Q.PEAK DUO XL-

G11S 585W (585W)

3,047 (1.78

MW)

Components

Description Combiner Poles String Size Stringing Strategy

Emergnecy Ops N - 1-1 Along Racking

Archives - 1-1 Along Racking

Emergency Ops S - 1-1 Along Racking

Coroners - 1-1 Along Racking

Garage - 1-1 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field Segment

Flush

Mount

Landscape

(Horizontal) 10° 325.20993° 0.0 ft 1x1 307 307

179.60 kW

Field Segment

Fixed Tilt

Portrait

(Vertical)

Module:

25°

Module:

165.68896°

12.0 ft 2x1 229 458

267.93 kW

Field Segment

5 (copy) Fixed Tilt

Portrait

(Vertical)

Module:

25° Module: 180° 12.0 ft 2x1 385 770

450.45 kW

Field Segment

8 (copy) Fixed Tilt

Portrait

(Vertical)

Module:

25° Module: 180° 12.0 ft 2x1 548 1,096

641.16 kW

Field Segment

7 (copy) Fixed Tilt

Portrait

(Vertical)

Module:

25° Module: 180° 12.0 ft 2x1 208 416

243.36 kW

Field Segments

Montco- Eagleville Campus- String_04212026 - Montgomery, 60 Eagleville

Rd, Eagleville, PA 19403

Project Name Montgomery

Project Address 60 Eagleville Rd, Eagleville, PA 19403

Prepared By Pennsylvania Solar Center info@pasolarcenter.org

Report

Design Montco- Eagleville Campus-

String_04212026

Module DC

Nameplate

1.78 MW

Inverter AC

Nameplate

1.26 MW

Load Ratio: 1.41

Annual

Production

2.252 GWh

Performance

Ratio 75.8% kWh/kWp 1,265.2

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Simulator Version 3d95575071-500033d1a3-

7a70f8553e-2e9c31aff5

System Metrics Project Location

Monthly Production kW h

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

100k

200k

300k

Sources of System Loss

Front ShadingFront Shading: 5.4%: 5.4%Front Shading: 5.4%

ReflectionReflection: 3.0%: 3.0%Reflection: 3.0%

SoilingSoiling: 5.2%: 5.2%Soiling: 5.2%

IrradianceIrradiance: 0.7%: 0.7%Irradiance: 0.7%TemperatureTemperature: 2.6%: 2.6%Temperature: 2.6%

ElectricalElectrical MismatchMismatch: 4.7%: 4.7% Electrical Mismatch: 4.7%

WiringWiring: 0.6%: 0.6%Wiring: 0.6%

ClippingClipping: 3.5%: 3.5%Clipping: 3.5%

InvertersInverters: 2.8%: 2.8%Inverters: 2.8%

AC SystemAC System: 0.5%: 0.5%AC System: 0.5%

BifacialityBifaciality: 0.8%: 0.8%Bifaciality: 0.8%

Rear MismatchRear Mismatch: 0.2%: 0.2%Rear Mismatch: 0.2%

Delta

Front

Irradiance

(kWh/m )

Annual Global Horizontal

Irradiance 1,476.0

POA Irradiance 1,669.2 13.1%

Shaded Irradiance 1,578.7 -5.4%

Irradiance after Reflection 1,531.7 -3.0%

Irradiance after Soiling 1,452.1 -5.2%

Total Front Collector

Irradiance 1,451.9 0.0%

Rear Irradiance

(kWh/m )

Supported only for fixed tilt racking

Surface

Irradiance in

Collector

Plane

Global Incident

Irradiance on

Surface

476.2 -

Surface Reflected

Irradiance after

Albedo

95.2 -80.0%

Conversion from

Surface Area to

Collector Area

157.0

Surface

Irradiance in

Collector Plane

30.7 -80.4%

Unshaded

Irradiance on

Rear Side

Surface Irradiance in Collector Plane 30.7

Sky Diffuse 11.7

Beam Effective 0.2

Total Unshaded

Irradiance on

Rear Side

42.7

Shaded Irradiance on Rear Side 40.5 -5.2%

Total Rear Collector Irradiance 40.5

Effective Rear Collector

Irradiance

28.3 -30.0%

Total Collector Irradiance 1,480.2

Energy

(kWh)

Nameplate 2,634,626.1

Output at Irradiance Levels 2,615,247.0 -0.7%

Output at Cell Temperature

Derate 2,548,119.8 -2.6%

Output after Electrical Mismatch 2,427,147.0 -4.7%

Output after Rear Mismatch 2,422,505.0 -0.2%

Optimal DC Output 2,413,224.4 -0.6%

Constrained DC Output 2,329,819.5 -3.5%

Inverter Output 2,263,520.3 -2.8%

Energy to Grid 2,252,202.8 -0.5%

Temperature Metrics

Avg. Operating Ambient Temp 14.6 °C

Avg. Operating Cell Temp 22.9 °C

Simulation Metrics

Operating Hours 4684

Solved Hours 4684

Annual Production

Description Condition Set 1

Weather Dataset TMY, 10km grid (40.15,-75.35), NREL (prospector)

Solar Angle

Location Meteo Lat/Lng

Transposition

Model Perez Model

Temperature Model Sandia Model

Temperature Model

Parameters

Rack Type a b Temperature Delta

Fixed Tilt -3.56 -0.075 3°C

Flush Mount -2.81 -0.0455 0°C

East-West -3.56 -0.075 3°C

Carport -3.56 -0.075 3°C

Soiling (%) J F M A M J J A S O N D

23 21 11 4 1 0 1 1 1 1 5 16

Albedo J F M A M J J A S O N D

0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20 0.20

Rear Mismatch

Loss 10% Rear Shading Factor 5%

Module

Transparency 0%

Irradiation Variance 5%

Cell Temperature

Spread 4° C

Module Binning

Range -2.5% to 2.5%

AC System Derate 0.50%

Module &

Component

Characterizations

Type Component Characterization Bifacial

Module

Q.PEAK DUO XL-G11S 585W

(QCells)

Spec Sheet Characterization, PAN

True

Inverter

CPS SCA 36KTL-DO (US)

(Chint) Manufacturer N/A

Condition Set

Annual Production Report produced by Pennsylvania Solar Center

CPS SCA 36KTL-DO (US)

(Chint)

35 (1.26 MW)

Strings 10 AWG (Copper)

(42,382.7 ft)

Module QCells, Q.PEAK DUO XL-

G11S 585W (585W)

3,043 (1.78

MW)

Components

Description Combiner Poles String Size Stringing Strategy

Emergency Ops S - 13-16 Along Racking

Archives - 13-16 Along Racking

Garage - 13-16 Along Racking

Coroners - 13-16 Along Racking

Emergnecy Ops N - 13-16 Along Racking

Wiring Zones

Description Racking Orientation Tilt Azimuth Intrarow

Spacing

Frame

Size Frames Modules Power

Field

Segment 5 Fixed Tilt

Portrait

(Vertical)

Module:

25° Module: 180° 12.0 ft 2x1 385 770

450.45 kW

Field

Segment 7 Fixed Tilt

Portrait

(Vertical)

Module:

25° Module: 180° 12.0 ft 2x1 208 416

243.36 kW

Field

Segment 8 Fixed Tilt

Portrait

(Vertical)

Module:

25° Module: 180° 12.0 ft 2x1 546 1,092

638.82 kW

Field

Segment 4

Flush

Mount

Landscape

(Horizontal) 10° 325.20993° 0.0 ft 1x1 307 307

179.60 kW

Field

Segment 5 Fixed Tilt

Portrait

(Vertical)

Module:

25°

Module:

165.68896°

12.0 ft 2x1 229 458

267.93 kW

Field Segments

File details come from the government source that posted it. Updated .