5.c 31025042_drw.pdf
PDF 397 KB Posted
- Solicitation number
- 475215
- Issued by
-
Department of Energy Office of Science
About this file
This is an envelope drawing for a Central Cryogenic Compressor System Aftercooler Vessel, designated drawing number 31025042, Revision A, prepared by Brookhaven National Laboratory's Collider-Accelerator Department. The drawing provides detailed technical specifications and dimensional requirements for a pressure vessel used in the RHIC (Relativistic Heavy Ion Collider) facility located in Upton, New York.
The aftercooler vessel features multiple connection ports with specific designations and functions, including two 3-inch Schedule 40 water inlet/outlet connections (FN1 and FN2), two 10-inch Schedule 40 helium inlet/outlet connections (FN3 and FN4), one 2-inch drain connection (FN5), four 2-inch inspection ports (FN6), one 2-inch vent connection (FN7), six 3/4-inch test connections (FN8), six 1/2-inch test connections (FN9), one 1/2-inch oil drain plug (FN10), and one anode connection (FN11). The vessel measures approximately 198 inches in length with various dimensional specifications detailed throughout. Key notes specify that vessel supports on the top are required on only two of the units and must include provisions for forklift and pallet jack forks per specification SPEC-CAD-1372 Section 3.3. The drawing is interpreted in accordance with SPEC-CAD-1372 Revision A and 31025045 Statement of Work Revision A, with all dimensions provided for reference purposes and tolerances conforming to ASME Y14.5 2009 standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 4. SPEC_CAD-1372.pdf | ||
| 5.b 31025041_drw.pdf | ||
| 5.d 31025043_drw.pdf | ||
| 5.e 31025046_Utility_HX.pdf | ||
| 2. RFI Document 475215.pdf | ||
| 1. RFI Letter 475215.pdf | ||
| 3. BNL_RHIC_CRYO_IX&AX_RFI_V3.pdf | ||
| 5.a 31025040_drw.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
7 6 5
C
D
NOTES:
8 7 6 5
COLLIDER-ACCELERATOR DEPARTMENT
SCALE:
DRAWING NUMBER:
FINISH
APPLICATION
4 3
CATEGORY
Q.A.
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
USED ON DRAWING NO. QTY. PER ASS'Y.
BREAK SHARP EDGES
ANGULAR TOLERANCE �#�1�$�
DECIMAL TOLERANCES
.X �#� .030
.XX �#� .015
.XXX �#� .005
ACCORDANCE WITH
ASME Y14.5 2009
INTERPRET IN GENERAL
D
SIZE
SHEET OFWEIGHT:
UPTON, N.Y. 11973 D
W G
N O
REV.
O F
S H T
B
ER V
4 3 2
C
D
.03 MAX. MIN. 015
CREO
BROOKHAVEN NATIONAL LABORATORY
4.0
4.8
9.5
6.3
12.5
2.5
2x 50.9
2x 106.9
18.0
198.0
24.0
156.0
5.1
17.0
27.0
22.0
162.0
4X 16.0
2X 45�$�
2X 4.0
2X 11.5
2X 16.0 2X 16.0
4X 10.5
141.5
138.5
12.0
2X 4.0
2X
THRU ONE WALL
.750
FN11 ANODE TBD"-3000# N.P.T. 1 ANODE
FN10 OIL DRAIN 1/2"-3000# N.P.T. 1 PLUGGED
FN9 TEST CONN. 1/2"-3000# N.P.T. 6 PLUGGED
FN8 TEST CONN. 3/4"-3000# N.P.T. 6 PLUGGED
FN7 VENT 2"-3000# N.P.T. 1 PLUGGED
FN6 INSPECTION 2"-3000# N.P.T. 4 PLUGGED
FN5 DRAIN 2"-3000# N.P.T. 1 PLUGGED
FN4 OUTLET 10"-SCH 40 WELD END 1 HELIUM
FN3 INLET 10"-SCH 40 WELD END 1 HELIUM
FN2 OUTLET 3" SCH 40 WELD END 2 WATER
FN1 INLET 3" SCH. 40 WELD END 2 WATER
MARK SERVICE CONNECTION DESCRIPTION QTY REMARKS
PORT INDEX
RHIC
CENTRAL CRYOGENIC COMPRESSOR SYSTEM
AFTERCOOLER VESSEL
31025042 A3
A
A 1279.4
REVISION APPROVALS
SUPVENGDESCHKBYDATEDESCRIPTIONECN NO.REV
------INITIAL RELEASE-A
31025043
1 1
ENVELOPE DRAWING
3/32DEPARTMENT
CHAIR
SAFETY / RSC
Q.A.
DIVISION
HEAD
CEE / CME
SUPERVISOR
APPROVAL R.FEDER 09/25
ENG / PHY
APPROVAL P.PATEL 09/25
DESIGN
APPROVAL R.LYNCH 09/25
CHECKED
BY J. KANDORA 08/18/25
DRAWN BY L.DEMINO 04/18/24
1. ALL DIMENSIONS ARE FOR REFERENCE.
2. VESSEL SUPPORTS ON TOP ARE ONLY REQUIRED ON (2) UNITS
3. SUPPORTS TO HAVE PROVISIONS FOR FORKLIFT & PALLET JACK FORKS AS SPECIFIED IN SPEC-CAD-1372 SECTION 3.3
INTERPRET IN ACCORDANCE WITH SPEC-CAD-1372 REV-A & 31025045SOW REV-A
FN5
FN7FN11
FN10
BOLTED OR WELDED CONNECTION
TBD
SEE NOTE 2SEE NOTE 2
SEE DETAIL A
DETAIL A
SCALE 5/32
4X
SECTION A-A
2X FN8
2X FN9
4X FN6
FN2
FN2
FN1
FN1
2X FN8
2X FN9
FN8
FN9
FN4
FN3
FN8
FN9