This is an envelope drawing for a Central Cryogenic Compressor System Aftercooler Vessel, designated drawing number 31025042, Revision A, prepared by Brookhaven National Laboratory's Collider-Accelerator Department. The drawing provides detailed technical specifications and dimensional requirements for a pressure vessel used in the RHIC (Relativistic Heavy Ion Collider) facility located in Upton, New York.

The aftercooler vessel features multiple connection ports with specific designations and functions, including two 3-inch Schedule 40 water inlet/outlet connections (FN1 and FN2), two 10-inch Schedule 40 helium inlet/outlet connections (FN3 and FN4), one 2-inch drain connection (FN5), four 2-inch inspection ports (FN6), one 2-inch vent connection (FN7), six 3/4-inch test connections (FN8), six 1/2-inch test connections (FN9), one 1/2-inch oil drain plug (FN10), and one anode connection (FN11). The vessel measures approximately 198 inches in length with various dimensional specifications detailed throughout. Key notes specify that vessel supports on the top are required on only two of the units and must include provisions for forklift and pallet jack forks per specification SPEC-CAD-1372 Section 3.3. The drawing is interpreted in accordance with SPEC-CAD-1372 Revision A and 31025045 Statement of Work Revision A, with all dimensions provided for reference purposes and tolerances conforming to ASME Y14.5 2009 standards.

View the file

Other files

File Type Posted
4. SPEC_CAD-1372.pdf PDF
5.b 31025041_drw.pdf PDF
5.d 31025043_drw.pdf PDF
5.e 31025046_Utility_HX.pdf PDF
2. RFI Document 475215.pdf PDF
1. RFI Letter 475215.pdf PDF
3. BNL_RHIC_CRYO_IX&AX_RFI_V3.pdf PDF
5.a 31025040_drw.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

7 6 5

C

D

NOTES:

8 7 6 5

COLLIDER-ACCELERATOR DEPARTMENT

SCALE:

DRAWING NUMBER:

FINISH

APPLICATION

4 3

CATEGORY

Q.A.

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

USED ON DRAWING NO. QTY. PER ASS'Y.

BREAK SHARP EDGES

ANGULAR TOLERANCE �#�1�$�

DECIMAL TOLERANCES

.X �#� .030

.XX �#� .015

.XXX �#� .005

ACCORDANCE WITH

ASME Y14.5 2009

INTERPRET IN GENERAL

D

SIZE

SHEET OFWEIGHT:

UPTON, N.Y. 11973 D

W G

N O

REV.

O F

S H T

B

ER V

4 3 2

C

D

.03 MAX. MIN. 015

CREO

BROOKHAVEN NATIONAL LABORATORY

4.0

4.8

9.5

6.3

12.5

2.5

2x 50.9

2x 106.9

18.0

198.0

24.0

156.0

5.1

17.0

27.0

22.0

162.0

4X 16.0

2X 45�$�

2X 4.0

2X 11.5

2X 16.0 2X 16.0

4X 10.5

141.5

138.5

12.0

2X 4.0

2X

THRU ONE WALL

.750

FN11 ANODE TBD"-3000# N.P.T. 1 ANODE

FN10 OIL DRAIN 1/2"-3000# N.P.T. 1 PLUGGED

FN9 TEST CONN. 1/2"-3000# N.P.T. 6 PLUGGED

FN8 TEST CONN. 3/4"-3000# N.P.T. 6 PLUGGED

FN7 VENT 2"-3000# N.P.T. 1 PLUGGED

FN6 INSPECTION 2"-3000# N.P.T. 4 PLUGGED

FN5 DRAIN 2"-3000# N.P.T. 1 PLUGGED

FN4 OUTLET 10"-SCH 40 WELD END 1 HELIUM

FN3 INLET 10"-SCH 40 WELD END 1 HELIUM

FN2 OUTLET 3" SCH 40 WELD END 2 WATER

FN1 INLET 3" SCH. 40 WELD END 2 WATER

MARK SERVICE CONNECTION DESCRIPTION QTY REMARKS

PORT INDEX

RHIC

CENTRAL CRYOGENIC COMPRESSOR SYSTEM

AFTERCOOLER VESSEL

31025042 A3

A

A 1279.4

REVISION APPROVALS

SUPVENGDESCHKBYDATEDESCRIPTIONECN NO.REV

------INITIAL RELEASE-A

31025043

1 1

ENVELOPE DRAWING

3/32DEPARTMENT

CHAIR

SAFETY / RSC

Q.A.

DIVISION

HEAD

CEE / CME

SUPERVISOR

APPROVAL R.FEDER 09/25

ENG / PHY

APPROVAL P.PATEL 09/25

DESIGN

APPROVAL R.LYNCH 09/25

CHECKED

BY J. KANDORA 08/18/25

DRAWN BY L.DEMINO 04/18/24

1. ALL DIMENSIONS ARE FOR REFERENCE.

2. VESSEL SUPPORTS ON TOP ARE ONLY REQUIRED ON (2) UNITS

3. SUPPORTS TO HAVE PROVISIONS FOR FORKLIFT & PALLET JACK FORKS AS SPECIFIED IN SPEC-CAD-1372 SECTION 3.3

INTERPRET IN ACCORDANCE WITH SPEC-CAD-1372 REV-A & 31025045SOW REV-A

FN5

FN7FN11

FN10

BOLTED OR WELDED CONNECTION

TBD

SEE NOTE 2SEE NOTE 2

SEE DETAIL A

DETAIL A

SCALE 5/32

4X

SECTION A-A

2X FN8

2X FN9

4X FN6

FN2

FN2

FN1

FN1

2X FN8

2X FN9

FN8

FN9

FN4

FN3

FN8

FN9

APPROVED

ELEC APPVL IN

W

INDCHILL

rfeder Stamp

Sheet 1
Views
new_view_6
top_7
A
left_9
right_10

File details come from the government source that posted it. Updated .