5.a 31025040_drw.pdf

PDF 492 KB Posted

Attached to
Request for Information (RFI) 475215, Helium-Water Shell-and-Tube Heat Exchangers
Solicitation number
475215
Issued by

About this file

This is an engineering envelope drawing for the Central Cryogenic Compressor System Intercooler Vessel, produced by Brookhaven National Laboratory's Collider-Accelerator Department for the RHIC (Relativistic Heavy Ion Collider) facility. Drawing number 31025040, Revision A, was drawn by L. Demino on 04/18/24 and checked by J. Kandora on 8/19/25, with design approval from R. Lynch, engineering approval from P. Patel, and safety approval from R. Feder, all dated 9/25.

The vessel specifications include overall dimensions of 112.5 inches in length with a maximum diameter of 31.9 inches and a weight of 3,453.2 pounds. The vessel features eleven nozzle connections (FN1-FN11) with varying specifications: two 3-inch Schedule 40 welded-end inlet/outlet connections for water service, two 10-inch Schedule 40 welded-end inlet/outlet connections for helium service, one 2-inch NPT vent, two 2-inch NPT inspection ports, one 2-inch NPT drain, six 3/4-inch and 1/2-inch NPT test connections, one 1/2-inch NPT oil drain (plugged), and one anode connection (TBD). The drawing incorporates dimensional tolerances per ASME Y14.5 2009 and references specification documents SPEC-CAD-1372 Rev-A and 31025045 SOW Rev-A for interpretation. Vessel supports are required on two units only with provisions for forklift and pallet jack forks. The document is controlled under U.S. Department of Commerce Export Control Administration Regulations as EAR99 technology.

View the file

Other files

File Type Posted
5.c 31025042_drw.pdf PDF
4. SPEC_CAD-1372.pdf PDF
5.b 31025041_drw.pdf PDF
5.d 31025043_drw.pdf PDF
5.e 31025046_Utility_HX.pdf PDF
2. RFI Document 475215.pdf PDF
1. RFI Letter 475215.pdf PDF
3. BNL_RHIC_CRYO_IX&AX_RFI_V3.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

7 6 5

C

D

NOTES:

8 7 6 5

COLLIDER-ACCELERATOR DEPARTMENT

SCALE:

DRAWING NUMBER:

FINISH

APPLICATION

4 3

CATEGORY

Q.A.

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

USED ON DRAWING NO. QTY. PER ASS'Y.

BREAK SHARP EDGES

ANGULAR TOLERANCE �#�1�$�

DECIMAL TOLERANCES

.X �#� .030

.XX �#� .015

.XXX �#� .005

ACCORDANCE WITH

ASME Y14.5 2009

INTERPRET IN GENERAL

D

SIZE

SHEET OFWEIGHT:

UPTON, N.Y. 11973 D

W G

N O

REV.

O F

S H T

B

ER V

4 3 2

C

D

.03 MAX. MIN. 015

CREO

BROOKHAVEN NATIONAL LABORATORY

10.052.0

2X 21.0

14.017.0

6.0

3.5

2X 36.0

7.0 8.5

4X

THRU ONE WALL

.875

2X 45.0�$�

4X 20.0

28.128.1

22.283.3

4X 23.0

2X 6.25

2X 6.25

31.7

35.0

18.0

67.0

57.0

5.8

112.5

31.9

21.0

4X 16.50

2X 21.0

2X 24.0

2X 6.25

14.8

8X 17.0

1.25

RHIC

CENTRAL CRYOGENIC COMPRESSOR SYSTEM

INTERCOOLER VESSEL

31025040 A3

A

A 3453.2

REVISION APPROVALS

SUPVENGDESCHKBYDATEDESCRIPTIONECN NO.REV

------INITIAL RELEASE-A

31025041

1 1

ENVELOPE DRAWING

3/32DEPARTMENT

CHAIR

SAFETY / RSC

Q.A.

DIVISION

HEAD

CEE / CME

SUPERVISOR

APPROVAL R.FEDER 9/25

ENG / PHY

APPROVAL P.PATEL 9/25

DESIGN

APPROVAL R.LYNCH 9/25

CHECKED

BY J. KANDORA 8/19/25

DRAWN BY L. DEMINO 04/18/24

FN11 ANODE TBD - 3000# N.P.T. 1 ANODE

FN10 OIL DRAIN 1/2" - 3000# N.P.T. 1 PLUGGED

FN9 TEST CONN. 1/2" - 3000# N.P.T. 6 PLUGGED

FN8 TEST CONN. 3/4" - 3000# N.P.T. 6 PLUGGED

FN7 VENT 2" - 3000# N.P.T. 1 PLUGGED

FN6 INSPECTION 2" - 3000# N.P.T. 2 PLUGGED

FN5 DRAIN 2" - 3000# N.P.T. 1 PLUGGED

FN4 OUTLET 10" SCH. 40 WELD END 1 HELIUM

FN3 INLET 10" SCH. 40 WELD END 1 HELIUM

FN2 OUTLET 3" SCH. 40 WELD END 2 WATER

FN1 INLET 3" SCH. 40 WELD END 2 WATER

MARK SERVICE CONNECTION DESCRIPTION QTY REMARKS

PORT INDEX

1. ALL DIMENSIONS ARE FOR REFERENCE

2. VESSEL SUPPORTS ON TOP ARE ONLY REQUIRED ON (2) UNITS

3. SUPPORTS TO HAVE PROVISIONS FOR FORKLIFT & PALLET JACK FORKS AS SPECIFIED IN SPEC-CAD-1372 SECTION 3.3

INTERPRET IN ACCORDANCE WITH SPEC-CAD-1372 REV-A & 31025045SOW REV-A

FN11

FN7

BOLTED OR WELDED CONNECTION

TBD

FN5

FN10

SEE NOTE 2SEE NOTE 2

2X HELIUM PIPE

CUT OFF POINT

FOR FIELD ERRECTION

2X FN8

FN4

2X FN9

FN3

SEE DETAIL A

DETAIL A

SCALE 3/16

4X

SECTION B-B

4X WATER PIPE

CUT OFF POINT

FOR FIELD ERRECTION

2X FN6

FN1

4X FN8

4X FN9

FN2

FN2

FN1

THIS INFORMATION IS CONTROLLED BY THE

U.S. DEPARTMENT OF COMMERCE EXPORT

CONTROL ADMINISTRATION REGULATIONS

15 CFR PARTS 730-774 AS EAR99 TECHNOLOGY

APPROVED

ELEC APPVL IN

W

INDCHILL

Sheet 1
Views
FRONT
RIGHT
TOP
A
left_10

File details come from the government source that posted it. Updated .