5-2-DA27002-26317480 Plans-CW Bldg. 21.pdf
PDF 46 MB Posted
- Solicitation number
- DA27002
- Issued by
- Utah
About this file
This is a permit set of architectural and structural construction plans for the Utah National Guard Camp Williams Building 21 Remodel project, prepared by the State of Utah Division of Facilities Construction and Management (DFCM) in coordination with Architectural NEXUS, Inc., and multiple engineering firms. The project involves a comprehensive renovation of the existing Building 21 facility located at 17800 S Redwood Road, Bluffdale, Utah, classified as a Level 3 Alteration under the 2021 International Existing Building Code. The scope of work includes complete demolition of existing interior construction; construction of new offices, conference rooms, and training rooms; modification and installation of mechanical, plumbing, and electrical systems; exterior upgrades including EIFS finish installation with added insulation; roofing system replacement; removal and replacement of doors and windows; and incorporation of dedicated IT spaces. All work is confined to the existing building footprint. The project is designed to accommodate up to 147 occupants with a total remodeled area of 5,432 square feet and includes compliance with accessibility requirements per ICC/ANSI A117.1-2009 standards. The permit set was dated May 15, 2026, and includes comprehensive architectural, structural, mechanical, plumbing, and electrical documentation with detailed specifications for wall assemblies, fire-rated construction, seismic requirements, and nonstructural component detailing.
The construction cost estimate for this project is $2,400,000.00. The project is being procured through a Stage II Invitation to Bid process, with eligibility restricted to contractors who have been prequalified under the DFCM Stage I Prequalification process and are currently listed on the DFCM Prequalified Contractors list as of the solicitation date. The design incorporates fire resistance ratings, seismic restraint requirements for nonstructural components, and deferred submittals for fire alarm and mass notification systems. Special inspections and testing are required for structural steel welding, bolted connections, concrete placement, and masonry construction in accordance with IBC Sections 1704 and 1705. All work must comply with applicable codes including the International Building Code, International Existing Building Code, International Energy Conservation Code, National Electrical Code, and Utah-specific amendments. The project includes provisions for structural observations by the engineer of record and requires coordination between all trades prior to construction commencement.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IND
USTRY
T H E
G R E A T
S E
A L
OF THE
S
T A T E
O F
U T A H
State of Utah-Department of Administrative Services
DIVISION OF FACILITIES CONSTRUCTION
AND MANAGEMENT
4315 South 2700 West, Floor 3/Taylorsville, Utah 84129-2128
NEXUS PROJECT #: DFCM PROJECT NO. 26317480
VICINITY MAP
PROJECT LOCATION
PROJECT DESCRIPTION:
DFCM APPROVAL
UTAH NATIONAL GUARD
CAMP WILLIAMS
BUILDING 21 REMODEL
17800 S Redwood Rd, Bluffdale, UT 84065
PERMIT SET
05.15.2026
25062
The projects scope of work consists of the Camp Williams existing South Building 21 Remodel constructed in the early 1990s, including comprehensive renovation of the existing interior and selective exterior upgrades to repurpose the facility for office, conference, and training functions.
Scope includes complete demolition of existing interior construction; construction of new offices, conference rooms, training rooms, and support spaces in accordance with the Contract Documents, including partitions, floor and wall finishes, casework, and specialties; modification and installation of mechanical systems and associated connections; updated plumbing systems, fixtures, and connections; and revised electrical distribution, lighting, power, and system routing. Additional work includes incorporation of dedicated IT spaces; removal and replacement of doors and windows;
installation of EIFS exterior finish with added insulation; and roofing system replacement. All work is confined to the existing building footprint and includes adjustment to occupant load while maintaining the existing occupancy classification. The project is classified as a Level 3 Alteration in accordance with the 2021 International Existing Building Code (IEBC).
GI000
COVER SHEET
R E
D W
O O
D R
D W 2700 N
I15
CAMP WILLIAMS
CONTACT: E-MAIL:
PHONE: INTERNET:
AGENCY
Utah National Guard 17800 S Redwood Rd
Lehi, UT 84045
801.471.9696
Jonathan Butler jonathan.d.butler21.nfg@army.mil http://www.guard.utah.gov/
CONTACT: E-MAIL:
PHONE: INTERNET:
ARCHITECT
Architectural NEXUS, Inc.
2505 East Parleys Way
Salt Lake City, UT 84109
801.924.5000
Stephen Springer sspringer@archnexus.com http://www.archnexus.com
CONTACT: E-MAIL:
PHONE: INTERNET:
STRUCTURAL ENGINEER
Structural Design Studio 2225 East Murray Holladay Rd., Suite 100
Salt Lake City, UT 84117
801.274.3950
Jake Merkley jake@structuralds.com http://www.structuralds.com
CONTACT: E-MAIL:
PHONE: INTERNET:
OWNER
Utah DFCM 43145 South 2700 West, Fl. 3
Taylorsville, UT 84129
801.960.7647
Randy Mellor rmellor@utah.gov http://www.dfcm.utah.gov
BID PACKAGE GENERAL NOTES
A. THIS BID PACKAGE SHALL BE BID IN ITS ENTIRETY. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS,
TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS
BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE
AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR
IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY.
B. AS PART OF THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE WORK OF ALL
SUB-CONTRACTORS, TRADES AND SUPPLIERS, THE CONTRACTOR SHALL ENDEAVOR
TO IDENTIFY AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS
BETWEEN THE WORK OF DIFFERENT PARTIES AT THE EARLIEST POSSIBLE DATE SO AS
TO ALLOW REASONABLE AND ADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED
WITHOUT DELAYING THE WORK. ALL DEVIATIONS FROM THAT WHICH IS REQUIRED BY
THE CONTRACT DOCUMENTS MUST BE APPROVED IN ADVANCE BY THE ARCHITECT.
C. IN CASE OF ANY DISCREPANCY WITHIN THE CONTRACT DOCUMENTS, THE MOST
STRINGENT REQUIREMENT OR MOST COSTLY OPTION SHALL APPLY, UNLESS
CLARIFICATION IS SOUGHT IN WRITING AND RECEIVED FROM THE ARCHITECT PRIOR
TO BIDDING. THE CONTRACTOR SHALL BRING ANY KNOWN DISCREPANCIES TO THE
ATTENTION OF THE ARCHITECT AS SOON AS POSSIBLE, AND IN ANY EVENT, PRIOR TO
COMMENCING AFFECTED WORK.
D. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE OF ANY CONFLICTS
BETWEEN VENDOR DRAWINGS AND THE CONTRACT DOCUMENTS. THE LATEST
VENDOR DRAWINGS SHALL GOVERN AND BE VERIFIED WITH THE OWNER AND THE
ARCHITECT.
E. THE ARCHITECTURAL DRAWINGS TAKE PRECEDENCE IN ESTABLISHING AND
COORDINATING THE FINISHED APPEARANCE AND EXACT LOCATION OF ALL EXPOSED
ELEMENTS OF THE WORK OF ALL TRADES, INCLUDING THAT WORK WHICH IS
ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES. QUANTITIES ARE TO
BE PROVIDED AS SHOWN ON DRAWINGS OF OTHER DISCIPLINES, BUT LOCATIONS
SHOWN ON OTHER DRAWINGS ARE SUBJECT TO COORDINATION WITH THE
ARCHITECTURAL DRAWINGS WHERE SUCH ITEMS ARE SHOWN, UNLESS OTHERWISE
NOTED ON THE ARCHITECTURAL DRAWINGS.
F. EXCEPT WHERE DIRECTED TO PLACE ITEMS OF WORK AT THE APPROXIMATE
LOCATION SHOWN, DO NOT SCALE DRAWINGS FOR DIMENSIONAL INFORMATION. NOT
ALL ELEMENTS OF THE DRAWINGS MAY BE DRAWN TO EXACT SCALE. ALL REQUIRED
DIMENSIONS ARE SHOWN OR MAY BE DERIVED FROM THOSE SHOWN ON THE
DRAWINGS, SCHEDULES AND SPECIFICATIONS. IF DIMENSIONS ARE NOT PRESENT, THE
ARCHITECT IS TO BE NOTIFIED SO THAT A CLARIFICATION CAN BE ISSUED. DIMENSIONS
ARE TO BE COORDINATED WITH ALL DISCIPLINES, VENDORS AND OWNER-FURNISHED
EQUIPMENT, FURNITURE AND DEVICES TO ASSURE PROPER PLACEMENT AND
WARRANTY REQUIREMENTS.
G. ALL CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CODES, ORDINANCES AND
REGULATIONS. SEE THE GI-SERIES SHEETS FOR PARTIAL REGULATORY INFORMATION,
INCLUDING CODE COMPLIANCE TABLES, RATED ASSEMBLY TYPES AND TYPICAL
ACCESSIBILITY CLEARANCE AND COMPLIANCE REQUIREMENTS.
H. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND THEIR
COMPATIBILITY WITH NEW CONSTRUCTION, AND COORDINATE ANY DISCREPANCIES
WITH THE ARCHITECT PRIOR TO PROCEEDING WITH AFFECTED WORK.
I. THE CONTRACTOR SHALL PROTECT ALL EXISTING FIRE-RESISTANCE-RATED
ASSEMBLIES AND SPRAY-APPLIED STRUCTURAL FIREPROOFING FROM DAMAGE.
PATCH AND FULLY REPAIR ANY DAMAGE TO SUCH ITEMS, WHETHER EXISTING OR
CAUSED BY NEW CONSTRUCTION OR DEMOLITION ACTIVITIES, TO LIKE-NEW
CONDITION IN ACCORDANCE WITH THE ORIGINAL LISTED SYSTEMS. SEAL ALL EXISTING
AND NEW ASSEMBLY PENETRATIONS WITH LISTED FIRE-RESISTANCE-RATED
ASSEMBLIES, WHERE OCCUR, TO MAINTAIN THE INTEGRITY OF THE ASSEMBLIES.
J. ALL UNUSED FLOOR SLAB PENETRATIONS 36 SQUARE INCHES OR LESS IN AREA ARE
TO BE INFILLED USING 4,000 PSI CONCRETE FOR THE FULL DEPTH OF THE EXISTING
SLAB. COORDINATED WITH ARCHITECT FOR INFILL OF LARGER OPENINGS.
SEE GI101
DESIGN CRITERIA
APPLICABLE CODES
OTHER CRITERIA
DEFERRED SUBMITTALS
FIRE ALARM / MASS NOTIFICATION SYSTEM
SEISMIC RESTRAINTS
CONTACT: E-MAIL:
PHONE: INTERNET:
MECHANICAL ENGINEER
Colvin Engineering 505 East South Temple, Suite 100
Salt Lake City, UT 84102
801.505.5417
Mike Dallon mike.dallon@lynkengineers.com http://www.cea-ut.com
CONTACT: E-MAIL:
PHONE: INTERNET:
ELECTRICAL ENGINEER
Colvin Engineering 505 East South Temple, Suite 100
Salt Lake City, UT 84102
801.698.2875
Tyler Squire tyler.squire@lynkengineers.com http://www.cea-ut.com
APPROVALS
Jonathan D. Butler, CFMO Manager Date
P R
O
FE
SS IONA L ENG
IN
E E
R
S
T A T E O F UT A
H
No. 318584-2202
Michael E. Dallon
05/15/2026
801.274.3950 :: structuralds.com
LANOISSEF
O
R P
ENG I N
E
E R
JACOB L.
MERKLEY
7937030
OETATS
F UTAH
05/15/2026
No.
8182456
TYLER
SQUIRE
L
IC
E N
S E D
PROFESS IONAL
E N G
I N E
E R
STATE OF UTAH
05/15/2026
MATCH LINE
A1 / Axxx
MATCH LINE TAG
EXISTING WALL TO REMAIN
WALL TO BE DEMOLISHED,
DEMOLISHED EQUIPMENT/FIXTURES
NEW WALL
BREAK LINE
CENTER LINE SYMBOL
0' x' y' z'
REVISION DESIGNATION
ELEVATION SYMBOL
REVISION NUMBER
ELEVATION ABOVE DATUM
ELEVATION DESCRIPTION
DRAWING SYMBOL LEGEND
CASEWORK TYPE DESIGNATION
CDS NUMBER (M DENOTES
MODIFICATION - SEE SHEET
A551 FOR MODIFIED MILLWORK
ELEVATIONS AND DETAILS)
AWS STANDARD CDS NUMBERING SYSTEM
WIDTH
HEIGHT DEPTH
NORTH ARROW
GRAPHIC SCALES
ROUND BREAK LINE
REVISION CLOUD
SLOPE INDICATION
##" / 12"
DETAIL REFERENCE
A2 A401
A1
A3
INTERIOR ELEVATIONS
DETAIL NUMBER
SHEET NUMBER
A1 A501
DETAIL REFERENCE
DETAIL NUMBER
SHEET NUMBER
A1 A201
EXTERIOR ELEVATION REFERENCE
SHEET NUMBER
DETAIL NUMBER
A1 A302
WALL SECTION REFERENCE
SHEET NUMBER
DETAIL NUMBER
A1 A301
BUILDING SECTION REFERENCE
DETAIL NUMBER
SHEET NUMBER
ROOM DESIGNATION (FLOOR PLAN)
ROOM NUMBER
ROOM NAME
A1 A301
DETAIL NUMBER
SHEET NUMBER
ROOM DESIGNATION (REFLECTED
CEILING PLAN)
CEILING HEIGHT ABOVE FINISH FLOOR
ROOM NUMBER
GLASS TYPE DESIGNATION
KEYED NOTE DESIGNATION
ASSEMBLY TYPE DESIGNATION
EQUIPMENT DESIGNATION
WINDOW DESIGNATION
DOOR DESIGNATION
GLASS TYPE
EQUIPMENT NAME
KEY NOTE NUMBER
WINDOW TYPE
DOOR NUMBER
ASSEMBLY TYPE (FLOOR, WALL, CEILING, ROOF)
MATERIAL TYPE DESIGNATION
FINISH TYPE
SEE AI601 FINISH LEGEND
RISE
RUN
CL
DETAIL / SHEET NUMBER
Room Name
1,500 SF
EQUIPMENT MARK#####
DESCRIPTION
100'-0"
T.O. WALL
###M #W
#H
#D
MODIFICATION DESCRIPTION
xx" = 1'-0" GRAPHIC SCALE
A1 A301
12"
TRUE NORTH
LIST OF ABBREVIATIONS
THE PRECEDING LIST OF ABBREVIATIONS
IS PRESENTED AS A GENERAL GUIDE AND
DOES NOT NECESSARILY SHOW ALL
ABBREVIATIONS USED. OTHER
GENERALLY ACCEPTED ABBREVIATIONS
MAY BE FOUND AMONG THE DRAWINGS -
SOME ABBREVIATIONS SHOWN ABOVE
MAY NOT BE USED WITHIN THIS DRAWING
SET.
A
A/C AIR CONDITIONING
ACT ACOUSTICAL CEILING TILE
APC ACOUSTICAL PANEL CEILING
AD AREA DRAIN
AFC ABOVE FINISHED CEILING
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALUM ALUMINUM
ANOD ANODIZED
ARCH ARCHITECT
@ AT
B
BD BOARD
BLDG BUILDING
BO BOTTOM OF
C
C CELSIUS
CH COAT HOOK
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CG CORNER GUARD
CI CONTINUOUS INSULATION
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CT CERAMIC TILE
CTJ CONSTRUCTION JOINT
D
D DEEP
DEG DEGREE
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
DWGS DRAWINGS
E
(E) EXISTING
EA EACH
EJ EXPANSION JOINT
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EOS EDGE OF SLAB
ERD EXISTING ROOF DRAIN
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
F
F FAHRENHEIT
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FDC FIRE DEPARTMENT CONNECTION
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FE FINISHED EDGE
FG FINISH GRADE
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FND FOUNDATION
FO FINISHED OPENING
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUD
FOW FACE OF WALL
FRG FIBER REINFORCED GYPSUM
FSP FIRE STANDPIPE
FT FEET
FV FIELD VERIFY
G
GA GAUGE
GALV GALVANIZED
GFRC GLASS-FIBER-REINFORCED
CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GL GLASS
GWB GYPSUM WALL BOARD
GYP GYPSUM
H
H HIGH
HB HOSE BIBB
HDR HEADER
HM HOLLOW METAL
HR HOUR
HT HEIGHT
I
ID INSIDE DIAMETER; INSIDE DIMENSION
IN INCH
INFO INFORMATION
INT INTERIOR
J
JAN JANITOR
K (NOT USED)
L
LAB LABORATORY
LAV LAVATORY
LBS POUNDS
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
M
MACH RM MACHINE ROOM
MAX MAXIMUM
MFR MANUFACTURER
MECH MECHANICAL
MEZZ MEZZANINE
MIN MINIMUM
MO MASONRY OPENING
N
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O
OC ON CENTER
OD OUTSIDE DIAMETER;
OUTSIDE DIMENSION
OFD OVERFLOW DRAIN
OH DR OVERHEAD DOOR
OFCI OWNER FURNISHED, CONTRACTOR
INSTALLED
OPH OPPOSITE HAND
OPP OPPOSITE
OFOI OWNER FURNISHED, OWNER INSTALLED
ORIG ORIGINAL
P
P LAM PLASTIC LAMINATE
PLAS PLASTER
PLUMB PLUMBING
PR PAIR
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
Q
QT QUARRY TILE
R
R RISER
RAD RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIDGERATOR
REQD REQUIRED
REV REVISION
RH RELATIVE HUMIDITY
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
RWL RAIN WATER LEADER
S
S SMOKE DETECTOR
SAM SELF ADHESIVE MEMBRANE
SCHED SCHEDULE
SECT SECTION
SIM SIMILAR
SPEC SPECIFICATION
SS STAINLESS STEEL
STD STANDARD
STRUCT STRUCTURAL
T
T TREAD
TEL TELEPHONE
TEMP TEMPORARY
THK THICK
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF SLAB; TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
TO TOP OF
U
UL UNDERWRITER'S LABORATORIES
UNO UNLESS NOTED OTHERWISE
V
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
W
W/ WITH
W/O WITHOUT
WD WOOD
WH WALL HYDRANT
WP WORKING POINT
WRB WEATHER RESISTIVE BARRIER
X,Y,Z (NOT USED)
CAST-IN-PLACE CONCRETE
CONCRETE MASONRY UNIT
PRECAST CONCRETE / GLASS FIBER
REINFORCED CONCRETE (GFRC)
BRICK VENEER
RIGID INSULATION
BATT INSULATION
CONTINUOUS MATERIAL
NON CONTINUOUS MATERIAL
(BLOCKING)
GYPSUM BOARD
PLYWOOD
UNDISTURBED EARTH
GRAVEL
HATCH LEGEND
NOTE: HATCHING ANGLES MAY VARY DUE TO ANGLE OF WALL DRAWN, WHILE HATCHING PATTERN REMAINS SIMILAR.
BACKFILL OR FILL
EXTERIOR SHEATHING
METAL
T
CR H IT
E
A
IC
E
L
NS E D
C
O UT
HS
TE
TA
F
A
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
DFCM APPROVAL
123456
E
D
C
B
A
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© ARCH NEXUS All Rights Reserved
STAMP
D F
C M
P R
O J E
C T
N O
05-15-26
STEPHEN M.
No. 7655609-0301
SPRINGER
/2
/2
:0
:2
P
M
A u to d e sk
D o c s:
U T
N G
C W
B
R e m o d e l_ r2
/A R
C H
_2
-U
T N
G C
W B
R e m o d e l_
.r v t
SHEET INDEX &
GENERAL
INFORMATION
AS
S R e d w o o d
R d
B lu ff d a le
U
T
U T
A H
N A
T
IO
N A
L G
U A
R D
25062
05.15.2026
PERMIT SET
GI001
SS
C A
M P
W
IL
L
IA
M S
B U
IL
D
IN
G
R E
M O
D E
L
# SHEET NAME
GENERAL:
GI000 COVER SHEET
GI001 SHEET INDEX & GENERAL INFORMATION
GI101 CODE ANALYSIS, EXITING AND OCCUPANCY PLAN
GI102 GENERAL CODE REQUIREMENTS
GI501 ASSEMBLY TYPES
GI701 ACCESSIBILITY COMPLIANCE
ARCHITECTURAL SITE:
AS101 ARCHITECTURAL SITE PLAN
STRUCTURAL
S001 GENERAL STRUCTURAL NOTES
S002 GENERAL STRUCTURAL NOTES
S101 FOOTING + FOUNDATION PLAN
S121 ROOF FRAMING PLAN
S201 EXTERIOR WALL REPAIR BUILDING ELEVATIONS
S501 STRUCTURAL DETAILS
ARCHITECTURAL:
AD101 ARCHITECTURAL DEMOLITION FLOOR PLAN
AD151 ARCHITECTURAL DEMOLITION RCP PLAN
AD201 DEMOLITION BUILDING ELEVATIONS
AE101 FLOOR PLAN
AE121 ROOF PLAN
AE151 REFLECTED CEILING PLAN
AE161 ATTIC PLAN
AE201 BUILDING ELEVATIONS
AE251 INTERIOR ELEVATIONS
AE301 BUILDING SECTIONS
AE351 WALL SECTIONS
AE501 ARCHITECTURAL DETAILS
AE502 ARCHITECTURAL DETAILS
AE551 MILLWORK DETAILS
AE601 DOOR & WINDOW SCHEDULE & TYPES
AE701 TYPICAL DETAILS
AI101 FINISH PLAN
AI401 ENLARGED FINISH PLANS
AI601 FINISH SCHEDULE & LEGEND
AI701 TYPICAL FINISH DETAILS
MECHANICAL:
M001 MECHANICAL LEGEND, SYMBOLS & ABBREVIATIONS
MH101 LEVEL 1 MECHANICAL PLAN
MH102 ROOF MECHANICAL PLAN
MH501 MECHANICAL DETAILS
MH601 MECHANICAL SCHEDULES
MH701 VRF SCHEMATIC
MH702 MECHANICAL SCHEMATICS
MP101 LEVEL 1 PIPING PLAN
PLUMBING:
P001 PLUMBING LEGEND, SYMBOLS & ABBREVIATIONS
PL100 UNDERGROUND PLUMBING PLAN
PL101 LEVEL 1 PLUMBING PLAN
PL401 ENLARGED PLUMBING PLANS
PL501 PLUMBING DETAILS
PL601 PLUMBING SCHEDULES
ELECTRICAL:
E-001 ELECTRICAL LEGEND, SYMBOLS & ABBREVIATIONS
ES101 ELECT SITE PLAN
EP101 LEVEL 1 POWER PLAN
EL101 LEVEL 1 LIGHTING PLAN
TN101 LEVEL 1 TELECOM PLAN
TY101 LEVEL 1 SECURITY PLAN
TA101 LEVEL 1 A/V PLAN
FA101 LEVEL 1 FIRE ALARM PLAN
E-501 ELECTRICAL DETAILS
E-601 ELECTRICAL SCHEDULES
E-602 ELECTRICAL SCHEDULES
E-603 ELECTRICAL SCHEDULES
E-701 ELECTRICAL ONE-LINES
E-702 ELECTRICAL ONE-LINES
SHEET INDEX
# Date Revision
SHOWER
SHOWER
WH
WH
North: ______ South: ______ East: ______ West: ______
Special Use and Occupancy (e.g. High Rise, Covered Mall): __________________
d) Unlimited Area Building: Yes ______ No ______ Code Section: ______ a a
3) Three Story: A (3)______
2) Two Story: A (2)______
1) One Story: ______
c) Total Allowable Area for:
1_< Allowable Area
Actual Area
b) Sum of the Ratio Calculations for Mixed Occupancies:
a) aA =
Official for Complex Buildings. Including, but not limited to:
g) Fire Stopping, Including Tested Design Number.
f) Exterior and Interior Accessibility Route.
e) Fire Assembly Locator Sheet.
a) High Rise Requirements.
b) Atriums.
c) Performance Based Criteria.
d) Means or Egress Analysis.
2) Additional Code Information shall be provided at the discretion of the Building
Code Accessibility Chapters, the more restrictive requirement shall govern.
through - ADA Guidelines and specific reference to the International Building
1) In case of conflict with the U.S. Department of Justice Federal Registers Parts
FOOTNOTES:
e) Drinking Fountains: ______ Service Sinks: ______
d) Bath Tubs or Showers: ______
c) Lavatories - Required (m) ______ (f) ______ Provided (m) ______ (f) ______
a) Water Closets - Required (m) ______ (f) ______ Provided (m) ______ (f) _____
M. Minimum Number of Required Plumbing Facilities:
Exit Width Required: __________ Exit Width Provided: ____________
Element Hours Assembly ListingListing
Element AssemblyHours
Smoke Partitions
Fire Partitions
Exterior Bearing Walls
Interior Bearing Walls
Exterior Non-Bearing Walls
Structural Frame
Partitions - Permanent
Fire Barriers
Floors - Ceiling Floors
Roofs - Ceiling Roofs
Exterior Doors and Windows
Shaft Enclosures
Fire Walls
BAHTBABABA
Design Wind Speed: ______ mphB. Seismic Design Category: ______
L. Design Occupant Load: __________________________________
K. Fire Resistance Rating Requirements for Building Elements (hours).
Area Modifications:J:
Tabular Area:I:
per Floor (square feet): ____________________________________Actual AreaH:
Number of Stories: ______ Building Height: ______G:
Required: ______ Provided: ______
Sprinklers:F:
Mixed Occupancies: ______ Nonseparated Uses: ______E.
separation distance (in hours):
Requirements for the Exterior Walls based on the fireFire Resistance RatingD.
C. Type of Construction (circle one):
Change in Use: Yes ______ No ______ Mixed Occupancy: Yes ______ No ______
Guildelines
ADA Accessibility
Building Conservation
Uniform Code for
National Electrical Code
Conservation Code
International Energy
International Fire Code
International Plumbing Code
International Mechanical Code
International Building Code
A. Occupancy and Group: ________ ________ ________ ________ ________
International Fuel Gas Code
Type of Sprinkler System (IBC 903.3.1)__________________
At A t+ +I fx A t Isx 0.25I =f F P 30W
b) Urinals - Required (m) ______ (f) ______ Provided (m) ______ (f) _____
(table 503): ____________________________________________
CODE ANALYSIS
APPLICABLE CODES
Year Year
A. SEE WALL TYPES ON FLOOR PLANS AND RATED WALL
ASSEMBLIES IN GI500s SHEET SERIES FOR SPECIFIC
WALL CONSTRUCTION TO ACHIEVE THE RATINGS
SHOWN ON THIS PLAN.
B. SEE AE700s SHEET SERIES FOR FIRE EXTINGUISHER
CABINET DETAILS.
GENERAL NOTES - REGULATORY PLANS
OCCUPANCY USE LEGEND
(none)
Assembly w/o Fixed Seating: Unconcentrated (A-3)
Business Areas: Seat Count (B)
Educational: Classroom Areas (E)
A-3
460 SF
CONFERENCE
E
1234 SF
TRAINING
GROSS SF = 5890
EXIT COMPONENT WIDTH
31 OCCUPANTS
6.2" WIDTH REQ'D (31 OCC. x 0.20" (1005.3.2,1))
32" MIN. CLR. EXIT WIDTH REQ'D (1010.1.1)
33" CLEAR WIDTH PROVIDED
EXIT COMPONENT WIDTH
37 OCCUPANTS
7.4" WIDTH REQ'D (37 OCC. x 0.20" (1005.3.2,1))
32" MIN. CLR. EXIT WIDTH REQ'D (1010.1.1)
33" CLEAR WIDTH PROVIDED
EXIT COMPONENT WIDTH
40 OCCUPANTS
8.0" WIDTH REQ'D (40 OCC. x 0.20" (1005.3.2,1))
32" MIN. CLR. EXIT WIDTH REQ'D (1010.1.1)
33" CLEAR WIDTH PROVIDED
EXIT COMPONENT WIDTH
39 OCCUPANTS
7.8" WIDTH REQ'D (39 OCC. x 0.20" (1005.3.2,1))
32" MIN. CLR. EXIT WIDTH REQ'D (1010.1.1)
33" CLEAR WIDTH PROVIDED
B
87 SF
1004.5
OFFICE
A-3
165 SF
CONFERENCE
B
86 SF
1004.5
OFFICE
B
161 SF
1004.5
OFFICE
B
85 SF
1004.5
OFFICE
B
164 SF
1004.5
OFFICE
B
85 SF
1004.5
OFFICE
B
86 SF
1004.5
OFFICE
B
148 SF
1004.5
OFFICE
B
87 SF
1004.5
OFFICE
B
88 SF
1004.5
OFFICE
B
148 SF
1004.5
OFFICE
B
86 SF
1004.5
OFFICE
B
85 SF
1004.5
OFFICE
B
88 SF
1004.5
OFFICE
CIRC.
KITCHENETTE
VESTIBULE IT JANITOR/MECH WOMEN'S
MEN'S
VESTIBULE
CIRCULATIONUNISEX
UNISEX
BREAK
OCCUPANCY
MAX. TRAVEL
DISTANCE
BUSINESS AREAS (B) 200'
TRAVEL DISTANCE
COMMON PATH OF TRAVEL
OCCUPANCY
MAX. TRAVEL
DISTANCE
BUSINESS AREAS (B) OL ≤ 30 = 100'
OL > 30 = 75'
PATH OF TRAVEL
EGRESS
NUMBER OF OCCUPANTS PER
EXIT/EGRESS PATH
OCCUPANCY TAG
ROOM NAME
Name
000 SF
A-3 000
ROOM AREA
OCCUPANCY TYPE
OCCUPANCY LOAD FACTOR
PER TABLE 1004.5 / 1004.6
OCCUPANT LOAD
FIRE EXTINGUISHERS
COORDINATE TYPE AND LOCATION
WITH LOCAL FIRE MARSHALL
EXIT ACCESS TRAVEL DISTANCE PER
TABLE 1017.2, WITHOUT SPRINKLERS:
COMMON PATH OF TRAVEL DISTANCE PER
TABLE 1006.2.1, WITHOUT SPRINKLERS:
FE
FIRE EXTINGUISHER; CLASS A-B-C
FEC
FIRE EXTINGUISHER CABINET; CLASS A-B-C
(EXISTING UTNG - BUILDING 21)
N/A
B
X X N/A
D 105
NO
N/A - EXISTING TO REMAIN
N/A
N/A
N/A
N/A
EXISTING, N/A
EXISTING
EXISTING
EXISTING
29.4", MIN 36" 144"
NO NO
+/- 17'-0"
N/AN/A
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
N/A
5,432 SF REMODEL
EXISTING
0 0 0 0
N / A
N/A
N/A N/A
OTHER CRITERIA
DFCM DESIGN CRITERIA AND GUIDELINES AND GENERAL CONDITIONS
NOTE: THESE DRAWINGS COMPLY WITH ALL THE REQUIREMENTS OF THE DFCM DESIGN CRITERIA AND GUIDELINES
NOTE: THESE DRAWINGS COMPLY WITH THE UTNG CONSTRUCTION GUIDELINES
NO
3 2 3 2 N/A N/A 2 N/A
3 2 3 2
ICC/ANSI A117.1-2009
International Existing Building Code 2021
Utah Amendments, Title 15A Current
2 REQ
2 PROVIDED
1 REQ
2 PROVIDED
2 SHOWERS PROVIDED
PER 2/3M 1/3F SPLIT OF USERS
NONSTRUCTURAL COMPONENT CHECKLIST
ITEM DESCRIPTION
ON CONSTR.
DOCUMENTS
DEFERRED
SUBMITTAL COMMENTS
ARCHITECTURAL COMPONENTS:
INTERIOR NONSTRUCTURAL WALLS &
PARTITIONS
CEILINGS (I.E. SUSPENDED GRID OR HARD-LID)
STORAGE RACKS
MEP COMPONENTS:
MECHANICAL EQUIPMENT (I.E. HVAC, FANS,
AIR HANDLERS, BOILERS, FURNACES, TANKS,
CHILLERS, WATER HEATERS, HEAT
EXCHANGERS, EVAPORATORS, ENGINES,
TURBINES, PUMPS, COMPRESSORS, MFR
EQUIPMENT, ETC.)
ELECTRICAL EQUIPMENT (I.E. GENERATORS,
BATTERIES, INVERTERS, TRANSFORMERS, MCC,
PANEL BOARDS, SWITCH GEAR, CABINETS,
ETC.)
COMMUNICATION EQUIPMENT, COMPUTERS,
INSTRUMENTATION, AND CONTROLS
LIGHTING FIXTURES
PIPING & CONDUIT SYSTEMS
DUCTWORK (INCLUDING IN-LINE COMPONENTS)
CABLE TRAYS
NOTES:
1. Deferred submittals for seismic restraint of nonstructural components must be submitted to the DFCM Building Official a minimum of two weeks prior to the planned installation in order to allow for plan review and forwarding to inspectors. In the event that the submittal is deficient additional time may become necessary.
2. When seismic restraint of non-structural components is installed prior to receiving DFCM approval it shall not be covered or concealed until receiving both plan review and inspection approval. Further, installers are proceeding at their own risk until plan review and inspection approval occurs.
3. The requirements for seismic restraint of nonstructural components cannot be satisfied by a general reference to Design Manuals.
The design professional may utilize these manuals as a basis of their design, but must provide all supporting documentation to ensure that the design conforms to the requirements of ASCE 7-05, Chapter 13.
4. Submittals must include details of the proposed seismic restraint of nonstructural components. These details must show specific information relating to the materials, type, size, and locations of anchorages; materials used for bracing; attachment requirements of bracing to structure and component; and locations of transverse and longitudinal sway bracing and rod stiffeners. Submittals may also require structural calculations, engineering reports, test data, and/or specifications to ensure code compliance.
T
CR H IT
E
A
IC
E
L
NS E D
C
O UT
HS
TE
TA
F
A
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
DFCM APPROVAL
123456
E
D
C
B
A
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© ARCH NEXUS All Rights Reserved
STAMP
D F
C M
P R
O J E
C T
N O
05-15-26
STEPHEN M.
No. 7655609-0301
SPRINGER
/2
/2
:0
:5
P
M
A u to d e sk
D o c s:
U T
N G
C W
B
R e m o d e l_ r2
/A R
C H
_2
-U
T N
G C
W B
R e m o d e l_
.r v t
CODE ANALYSIS,
EXITING AND
OCCUPANCY
PLAN
AS
S R e d w o o d
R d
B lu ff d a le
U
T
U T
A H
N A
T
IO
N A
L G
U A
R D
25062
05.15.2026
PERMIT SET
GI101
SS
C A
M P
W
IL
L
IA
M S
B U
IL
D
IN
G
R E
M O
D E
L
1/8" = 1'-0"GI101
A6 LEVEL 01 - OCCUPANCY & EXITING PLAN
EGRESS PATH LENGTHS
PATH #
COMMON PATH
OF TRAVEL
LONGEST PATH
OF TRAVEL
1 0" 68' - 6"
2 12' - 7" 63' - 3"
THIS SHEET TO BE
PRINTED / VIEWED IN COLOR.
# Date Revision
TAG DESCRIPTION #
FEC CLASS A-B-C; SEMI-RECESSED CABINET 3
T
CR H IT
E
A
IC
E
L
NS E D
C
O UT
HS
TE
TA
F
A
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
DFCM APPROVAL
123456
E
D
C
B
A
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© ARCH NEXUS All Rights Reserved
STAMP
D F
C M
P R
O J E
C T
N O
05-15-26
STEPHEN M.
No. 7655609-0301
SPRINGER
/2
/2
:0
:5
P
M
A u to d e sk
D o c s:
U T
N G
C W
B
R e m o d e l_ r2
/A R
C H
_2
-U
T N
G C
W B
R e m o d e l_
.r v t
GENERAL CODE
REQUIREMENTS
AS
S R e d w o o d
R d
B lu ff d a le
U
T
U T
A H
N A
T
IO
N A
L G
U A
R D
25062
05.15.2026
PERMIT SET
GI102
SS
C A
M P
W
IL
L
IA
M S
B U
IL
D
IN
G
R E
M O
D E
L
A. WALL HEIGHT: ALL NEW INTERIOR WALL ASSEMBLIES ARE
CONTINUOUS TO BOTTOM OF DECK UNLESS NOTED OTHERWISE.
REFER TO THE LEGENDS ON THIS SHEET AND COORDINATE WITH
PLANS.
B. TILE BACKER / CEMENT BOARD: WALL TYPES DESCRIBED ON THIS
SHEET DO NOT SHOW OR ACCOUNT FOR REQUIREMENTS WHERE A
TILE FINISH OCCURS. WHERE THE FINISH SCHEDULE OR INTERIOR
ELEVATIONS CALL FOR TILE, REPLACE GYPSUM BOARD SHOWN IN
THAT WALL'S ASSEMBLY WITH TILE BACKER / CEMENT BOARD
WHERE THE TILE OCCURS. REPLACE OTHER GYPSUM BOARD
SHOWN IN THAT WALL'S ASSEMBLY WITH MOISTURE RESISTANT
GYPSUM BOARD WHERE NO TILE OCCURS.
C. BACKING / SUPPORT: WALL TYPES DESCRIBED ON THIS SHEET DO
NOT ACCOUNT FOR REQUIRED BACKING. CONTRACTOR TO
PROVIDE BACKING / SUPPORT FOR ALL MOUNTED FIXTURES,
EQUIPMENT, CASEWORK, AND/OR SYSTEMS FURNITURE.
COORDINATE WITH FLOOR PLANS, AND INTERIOR ELEVATIONS
PRIOR TO THE COVERING OF STUD FRAMING. REFER TO
MANUFACTURER'S RECOMMENDATIONS WHERE APPLICABLE,
OTHERWISE REFER TO DETAILS ON A700s SHEET SERIES.
D. STRUCTURAL SHEATHING: REFER TO STRUCTURAL DRAWINGS FOR
STRUCTURAL SHEATHING REQUIREMENTS AND ATTACHMENTS.
E. SEISMIC BRACING: PROVIDE SEISMIC BRACING AT ALL WALL TYPES
THAT DO NOT EXTEND TO DECK, REFER TO DETAILS ON A700s
SHEET SERIES.
F. PENETRATIONS: PENETRATIONS THROUGH FIRE RATED
ASSEMBLIES SHALL BE PROVIDED PER G550s SHEET SERIES.
G. LISTED ASSEMBLIES: RATED ASSEMBLIES PROVIDED PER G550s
SHEET SERIES.
H. ACOUSTIC WALLS: AT ALL WALLS WITH SOUND ATTENUATION, SEAL
ENTIRE TOP AND BOTTOM OF WALL WITH SOUND SEALANT.
I. DEFLECTION TRACK: AT ALL WALLS THAT EXTEND TO STRUCTURE
PROVIDE DEFLECTION TRACK. REFER TO DETAILS ON A700s SHEET
SERIES.
J. RATED WALL PRIORITY: FOR PARTITION PRIORITY FOR
SEQUENCING OF RATED WALL CONSTRUCTION REFER TO DETAILS
ON A700s SHEET SERIES.
K. INFORMATION IN THE LEGENDS BELOW IS FOR REFERENCE ONLY
AND DOES NOT OVERRIDE THE CONTENTS OF THE DETAILS ON THIS
SHEET.
L. DO NOT SCALE DRAWINGS.
GENERAL NOTES -
WALL TYPE ASSEMBLIES
XS#1.1
PREFIX: 'X' FOR EXTERIOR CORE WALL
CONSTRUCTION TYPE (SEE BELOW)
STRUCTURE THICKNESS (TO NEAREST No.)
FIRE RATING (AS NEEDED, SEE BELOW)
EXTERIOR WALL TAG LEGEND
S61M(C)
CONSTRUCTION TYPE (SEE BELOW)
STRUCTURE THICKNESS (TO NEAREST No.)
FIRE RATING (AS NEEDED, SEE BELOW)
MODIFIERS (AS NEEDED, SEE BELOW)
CONSTRUCTION TYPES
CONCRETE C
MASONRY M
STEEL STUDS S
C-H (SHAFTWALL) STUD H
WOOD STUDS W
CONCRETE C
MASONRY M
STEEL STUDS S
C-H (SHAFTWALL) STUD H
WOOD STUDS W
DOUBLE STUD #D
ACOUSTIC RATING A
FURRING F
GYP. ONE SIDE G
LEAD SHIELDING L
RF SHIELDING R
MAGNETIC SHIELDING M
TOP OF WALL CONDITION MODIFIER (SEE BELOW)
SEE TABLE BELOW
TOP OF WALL MODIFIERS
(U) = UNDERSIDE / BOTTOM OF CEILING
WALL EXTENDS TO UNDERSIDE OF
CEILING. TERMINATE WITH "J" MOULD AT
GYP. BOARD WALLS.
EXAMPLE
LINE OF STRUCTURE ABV. TYP.
CEILING, TYP.
SUBSTRATE, TYP.
0 HOUR (SMOKE) 0
1 HOUR 1
2 HOUR 2
3 HOUR 3
4 HOUR 4
NO RATING NOT SHOWN
FIRE RATING
1 HOUR 1
2 HOUR 2
3 HOUR 3
4 HOUR 4
NO RATING NOT SHOWN
TYPE (AS NEEDED)
INTERIOR WALL TAG LEGEND
CONSTRUCTION TYPES FIRE RATING
MODIFIER EXAMPLES TOP OF WALL CONDITIONS
(C) = 6" ABOVE CEILING
WALLS WILL TERMINATE AT 6" ABOVE THE HIGHEST
ADJOINING CEILING (UNLESS OTHERWISE NOTED)
OR 1 FULL COURSE ABOVE FOR MASONRY WALLS.
(H) = PARTIAL HEIGHT
REFER TO DRAWINGS FOR TOP OF
WALL ELEVATION
(S) = ONE SUBSTRATE TO STRUCTURE
SUBSTRATE BOARD WILL TERMINATE TO BOTTOM
OF DECK ON ONE SIDE AND THE OTHER SIDE SHALL
TERMINATE AT 6" ABOVE ADJOINING CEILING
(UNLESS OTHERWISE NOTED). TERMINATE 1 FULL
COURSE ABOVE FOR MASONRY WALLS.
(N) = NO SUBSTRATES TO STRUCTURE
SUBSTRATE BOARDS WILL TERMINATE AT 6" ABOVE
ADJOINING CEILING (UNLESS OTHERWISE NOTED)
OR 1 FULL COURSE ABOVE FOR MASONRY WALLS.
BRACING, TYP.
DETAILS PROVIDED PER A700s SHEET SERIES.
STUDS, TYP.
6" A
BV
6"
A
BV
6" A
BV
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
G1 N/A N/A N/A N/A
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
S3 N/A N/A N/A N/A
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
S3A N/A N/A
STC 40 NGC 2016074
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
S3GA
N/A N/A
STC 34 NGC 2013012
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
M8 N/A N/A N/A N/A
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
3.5" SOUND ATTENUATION
BLANKET
3 5/8" METAL STUD FRAMING @ 16"
O.C. MAX
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
3 5/8" METAL STUD FRAMING @ 16"
O.C. MAX
ACOUSTIC SEALANT EACH
SIDE AT TOP AND BOTTOM
3 5/8" METAL STUD FRAMING @ 16"
O.C. MAX
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
3.5" SOUND ATTENUATION
BLANKET
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
S6 N/A N/A N/A N/A
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
6" METAL STUD FRAMING @ 16"
O.C. MAX
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
S6GA
N/A N/A
STC 37 NGC 2013021
6" METAL STUD FRAMING @ 16"
O.C. MAX
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
6" SOUND ATTENUATION BLANKET
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
EF#
N/A N/A N/A N/A
EXTERIOR INTERIOR
EIFS ON # MINERAL WOOL
INSULATION BOARD
ACOUSTIC SEALANT EACH
SIDE AT TOP AND BOTTOM
ACOUSTIC SEALANT EACH
SIDE AT TOP AND BOTTOM
1" AIR GAP
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
S6A N/A N/A
STC 44 NGC 2018133
ACOUSTIC SEALANT EACH
SIDE AT TOP AND BOTTOM
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
6" METAL STUD FRAMING @ 16"
O.C. MAX
6" SOUND ATTENUATION BLANKET
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
S3G N/A N/A N/A N/A
3 5/8" METAL STUD FRAMING @ 16"
O.C. MAX
(1) LAYER 5/8" TYPE 'X' GYPSUM
BOARD
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
C8 N/A N/A N/A N/A
CAST-IN-PLACE CONCRETE;
COORDINATE WITH STRUCTURAL
SCHEDULED EXTERIOR WALL,
SEE PLANS
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
M8F N/A N/A N/A N/A
EXTERIOR INTERIOR
8" CONCRETE MASONRY UNIT;
FIELD VERIFY & MATCH EXISTING
6" STRUCTURAL METAL STUD
FRAMING @ 16" O.C. MAX
EF2 = 2"
EF3 = 3"
EF4 = 4"
AIR GAP, MATCH EXISTING
FLUID-APPLIED AIR & WATER
BARRIER, VAPOR IMPERMEABLE
8" CONCRETE MASONRY UNIT;
FIELD VERIFY & MATCH EXISTING
SCHEDULED WALL, SEE PLANS
4 7/8" 4 7/8" 4 1/4" 4 1/4"
7 1/4" 7 1/4" 6 5/8"
FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
WALL TYPE:
T1 N/A N/A N/A N/A
SCHEDULED WALL, SEE PLANS
TILE, SEE FINISH SCHEDULE
CEILING TYPE: FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:CT0.3
CEILING TYPE: FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:CS3.1
24" X 24" ACOUSTICAL CEILING
PANEL
(1) LAYER 5/8" GYPSUM BOARD
3 5/8" STRUCTURAL METAL STUD
FRAMING @ 16" O.C. MAX
HANGER WIRE
CEILING TRACK; REFER TO
DETAILS ON AE701.
A. REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL DECKING
REQUIREMENTS AND ATTACHMENTS.
B. PROVIDE SEISMIC BRACING AT WALL TYPES THAT DO NOT EXTEND
TO DECK. REFER TO DETAILS ON A700s SHEET SERIES.
C. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE
PROVIDED PER DETAILS ON G550s SHEET SERIES.
D. INFORMATION SUPPLIED ON THIS SHEET IS SUPPLIED AS A BASE
CASE AND IS SUPERCEDED BY LOCATION SPECIFIC DETAIL
DRAWINGS.
E. REFER TO TYPICAL DETAILS ON A700s SHEET SERIES FOR
HORIZONTAL AND VERTICAL CONNECTIONS.
F. ALL FIRE RATED ASSEMBLIES TO BE CONTINUOUS; FIRE CAULK
AND/OR FIRE SAFING TO BE PROVIDED AT ALL ASSEMBLY
TERMINATIONS.
G. ALL ACOUSTICALLY RATED ASSEMBLIES TO BE CONTINUOUS;
ACOUSTIC CAULK TO BE PROVIDED AT ASSEMBLY TERMINATIONS
OR PENETRATIONS.
H. LIGHT FIXTURES IN CEILINGS TO RECEIVE BATT INSULATION ON
TOP SHALL HAVE A BOX OUT TO PROTECT THE INSULATION FROM
THE HEAT OF THE LIGHT SOURCE PER DETAIL.
I. ALL EXPOSED INTERIOR CONCRETE IS TO BE SEALED UNLESS
NOTED OTHERWISE.
J. INFORMATION IN THE LEGEND BELOW IS FOR REFERENCE ONLY
AND DOES NOT OVERRIDE THE CONTENTS OF THE DETAILS ON
THIS SHEET.
K. DO NOT SCALE DRAWINGS.
GENERAL NOTES -
HORIZONTAL ASSEMBLIES
RC#1.1
PREFIX: 'R' FOR ROOF
CONSTRUCTION TYPE (SEE BELOW)
STRUCTURE THICKNESS (TO NEAREST No.)
FIRE RATING (AS NEEDED, SEE BELOW)
ROOF TAG LEGEND
CONSTRUCTION TYPES
COMPOSITE CONC. C
STEEL DECK S
WOOD JOIST / TRUSS W
POST-TENSIONED CONC. P
CONC. WAFFLE SLAB F
FIRE RATING
TYPE (AS NEEDED)
XCS#1.11
PREFIX: 'C' FOR CEILING
CONSTRUCTION TYPE (SEE BELOW)
STRUCTURE THICKNESS (TO NEAREST No.)
FIRE RATING (AS NEEDED, SEE BELOW)
CEILING TAG LEGEND
CONSTRUCTION TYPES
CONCRETE C
STEEL FRAMING S
SUSPENDED TRACK T
C-H (SHAFTWALL) STUD H
WOOD FRAMING W
FINISH F
FIRE RATING
1 HOUR
2 HOUR
3 HOUR
4 HOUR
NO RATING
TYPE (AS NEEDED)
PREFIX: 'X' FOR EXTERIOR
(AS NEEDED)
FC#2.1
PREFIX: 'F' FOR FLOOR
CONSTRUCTION TYPE (SEE BELOW)
STRUCTURE THICKNESS (TO NEAREST No.)
FIRE RATING (AS NEEDED, SEE BELOW)
FLOOR TAG LEGEND
CONSTRUCTION TYPES
CONCRETE C
CONCRETE, S.O.G G
CONCRETE PAD P
STEEL JOIST / TRUSS S
WOOD JOIST / TRUSS W
METAL DECK W/ SUBSTRATE D
FIRE RATING
TYPE (AS NEEDED)
CS#1.11
INTERIOR FINISH TYPES
GYPSUM BOARD .1
ACT .3
WOOD .5
EXTERIOR FINISH TYPES
METAL PANEL .6
PROFILED METAL PANEL .7
EIFS .9
FINISH INDICATOR (SEE BELOW)
NOT SHOWN
1 HOUR 1
2 HOUR 2
3 HOUR 3
4 HOUR 4
NO RATING NOT SHOWN
1 HOUR 1
2 HOUR 2
3 HOUR 3
4 HOUR 4
NO RATING NOT SHOWN
FLOOR TYPE: FIRE RATING:
FIRE TEST:
SOUND RATING: TEST:
N/A
N/A
N/A N/AFG5
CAST-IN-PLACE CONCRETE;
COORDINATE WITH STRUCTURAL
SCHEDULED FINISH, SEE FINISH
PLANS AND SCHEDULE FOR TYPE
AND LOCATION
COMPACTED GRAVEL SUB-BASE
ROOF TYPE:
FIRE RATING:
SOUND RATING: TEST:RW.1 1 HOUR, CLASS B
STANDING SEAM METAL ROOF.
COLOR: COLONIAL RED
SELF-ADHERED ICE AND WATER
SHIELD, ENSURE MINIMUM 6"
OVERLAP WHERE APPLICABLE
WOOD TRUSS (EXISTING)
7/16" PLYWOOD (EXISTING)
(2) LAYERS OF 3” RIGID
INSULATION. SEAL ALL JOINTS,
SEAMS, FASTENERS AND
PENETRATIONS
3/8" DENSDECK PROFAST PRIME
ROOF BOARD
T
CR H IT
E
A
IC
E
L
NS E D
C
O UT
HS
TE
TA
F
A
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
DFCM APPROVAL
123456
E
D
C
B
A
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© ARCH NEXUS All Rights Reserved
STAMP
D F
C M
P R
O J E
C T
N O
05-15-26
STEPHEN M.
No. 7655609-0301
SPRINGER
/2
/2
:1
:0
P
M
A u to d e sk
D o c s:
U T
N G
C W
B
R e m o d e l_ r2
/A R
C H
_2
-U
T N
G C
W B
R e m o d e l_
.r v t
ASSEMBLY
TYPES
AS
S R e d w o o d
R d
B lu ff d a le
U
T
U T
A H
N A
T
IO
N A
L G
U A
R D
25062
05.15.2026
PERMIT SET
GI501
SS
C A
M P
W
IL
L
IA
M S
B U
IL
D
IN
G
R E
M O
D E
L
A. DETAILS AND DIAGRAMS ON THIS SHEET ARE
PROVIDED AS A MINIMUM DEMONSTRATION OF
ACCESSIBILITY REQUIREMENTS BASED ON THE 2009
ICC / ANSI A117.1 STANDARDS. SEE THE
AFOREMENTIONED STANDARD FOR A
COMPREHENSIVE COLLECTION OF DETAILS AND
BUILDING BLOCKS. SEE PROJECT SPECIFIC DETAILS
FOR ADDITIONAL INFORMATION. VERIFY WITH
ARCHITECT ANY DIFFERENCES OR DISCREPANCIES
BEFORE PROCEEDING WITH CONSTRUCTION.
B. PROVIDE BACKING / SUPPORT FOR ALL MOUNTED
FIXTURES, EQUIPMENT, CASEWORK, AND / OR
SYSTEMS FURNITURE. COORDINATE WITH FLOOR
PLANS, AND INTERIOR ELEVATIONS PRIOR TO THE
COVERING OF STUD FRAMING. REFER TO
MANUFACTURER'S RECOMMENDATIONS WHERE
APPLICABLE, OTHERWISE REFER TO DETAILS ON
AE700s SHEET SERIES.
C. DO NOT SCALE DRAWINGS.
GENERAL NOTES - ACCESSIBILITY
EXISTING BUILDING
CIRCULAR TURNING AREA
OVERLAP OF KNEE & TOE CLEARANCES T-SHAPED TURNING SPACES SHALL BE PERMITTED TO INCLUDE KNEE AND TOE
CLEARANCE COMPLYING WITH SECTION 306 OF EITHER THE BASE OR ONE ARM
5' - 0"
2'
1"
EXISTING BUILDING
CIRCULAR TURNING AREA
EXISTING BUILDING
T-SHAPED TURNING AREA
5'
0"
5' - 0"
1' - 0" 3' - 0" 1' - 0"
EXISTING BUILDING
T-SHAPED TURNING AREA
EXISTING BUILDING
CLEAR FLOOR AREA
2' - 6"
4'
0"
EXISTING BUILDING
CLEAR FLOOR AREA
VERTICAL CHANGES IN
LEVELS
1/4" MAX
BEVELED CHANGES IN
LEVELS
GREATER THAN 1/4" BUT NOT MORE
THAN 1/2" MAX SHALL BE BEVELED
WITH A SLOPE NOT STEEPER THAN
1:2
PREDOMINANT DIRECTION OF TRAVEL
LONG DIM. PERP. TO
DIRECTION OF TRAVEL
1/2" MAX
36"MIN
X
4"
60"MIN
X
5"
CLEAR FLOOR SPACE
FORWARD APPROACH
CLEAR FLOOR SPACE
PARALLEL APPROACH
MANEUVERING CLEARANCE
IN AN ALCOVE
FORWARD APPROACH
MANEUVERING CLEARANCE
IN AN ALCOVE
PARALLEL APPROACH
52" x 30" CLEAR FLOOR AREA FOR NEW BUILDINGS REPRESENTED
TO
C
O N
TR
O
LS
"M
AX
PAPER TOWEL
DISPENSER AND
TRASH
(UNOBSTRUCTED)
PAPER TOWEL
DISPENSER
(UNOBSTRUCTED)
SANITARY NAPKIN
VENDOR
(UNOBSTRUCTED)
TO
O
PE
N
IN
G
"M
AX
TOILET SEAT
COVERS
(UNOBSTRUCTED)
BABY CHANGING
STATION
(UNOBSTRUCTED)
HAND DRYER
(UNOBSTRUCTED)
TO
C
O N
TR
O
LS
"M
AX
18"MIN
TO
R
EF
LE
C
TI
VE
S
U R
FA
C
E
"M
IN
"M
AX
FULL LENGTH
MIRROR
(UNOBSTRUCTED)
TO
R E
FL
E
C
TI
V E
S
U R
FA
C
E
TO
D
IS
PE
N
SE
R
"M
AX
TO
D
IS
PE
N
SE
R
"M
AX
"M
AX
13 1/2" MIN
"M
IN
39" -41"
12"MAX 42"MIN.
54"MIN.
36"MIN 6"MAX
16" -18"
60"MIN.
NOTE: DIMENSIONS ARE TO TOP/BOTTOM OF GRAB BARS UNLESS NOTED OTHERWISE.
7" -9"
"M
IN
CL
1/
2" M
IN
. C
LE
AR
"M
IN
. C
LE
AR
" M
AX
RECESSED
DISPENSERS ARE
ALLOWED WITHIN
SHADED AREA
TOILET PAPER DISPENSER LOCATION
" M
IN
W
AL
L
H U
N G
T O
IL
ET
42"MIN
FLUSH CONTROLS SHALL BE LOCATED
ON THE OPEN SIDE OF THE WATER
CLOSET IN ACCESSIBLE STALLS.
17"MIN.
"M
AX
"M
IN
C
LE
AR
AN
C E
9" M
IN
. T
O E
11"MIN.
8"MIN.
LEG CLEARANCE
"M
AX
"M
IN
"M
AX
"M
AX
ADA STYLE LEVER FAUCETSSOAP DISPENSER
MIRROR
INSULATED PIPES
"M
IN
30"MIN.
TO
R
E
FL
E C
TI
V
E S
U R
FA
C
E
" M
IN
" M
AX
18"
BACK
1/2" MAX THRESHOLD
(BEVELED ROUNDED
OR VERTICAL)
SEAT WALL
CENTERLINE OF
CONTROL WALL
"M
IN
"M
AX
60" LONG HOSE, MIN. W/
VERTICAL BAR FOR
ADJUSTABLE HEIGHT OF
HAND SHOWER. MOUNT SO
AS TO NOT OBSTRUCT THE
USE OF GRAB BARS.
CONTROL AREA
CONTROL WALL
SEAT SEAT
" M
IN
3"
- 6
4"
MAX
15"
NOTE: DIMENSIONS ARE TO TOP/BOTTOM OF GRAB BARS.
CLEAR FLOOR SPACE
S E
A T
W A
LL
C O
N
TR
O L
W A
LL
BACK
18"
CLEAR INSIDE
36"
" M
IN
C
LE
AR
IN
SI
D
E
52"MIN
4" C L
18" VERTICAL
GRAB BAR
CLEAR FLOOR SPACE
S E
A T
W A
LL
C O
N
TR
O L
W A
LL
BACK
18"
CLEAR INSIDE
36"
" M
IN
C
LE
AR
IN
SI
D
E
52"MIN
4" C L
18" VERTICAL
GRAB BAR
NEW BUILDING OPT. 1
4"MAX
NEW BUILDING OPT. 2
22" -23"MAX.
2 1/2"MAX.
15" -16"MAX.
1/
2" M
AX
" M
IN
.1
5" M
AX
3" M
AX
SEAT DESIGN PER SECTION 610
WALL MOUNTED SIGNAGE TO BE
LOCATED ON LATCH SIDE OF DOOR &
CLEAR OF DOOR SWING. MOUNT AT 48"
MIN TO 60" MAX TO BOTTOM OF RAISED
LETTERING FROM FINISH FLOOR
WOMEN
WOMENHEIGHT OF LETTERING, 5/8"
TO 2" MAX, WITH UPPER
CASE CHARACTERS
CORRESPONDING GRADE 2 BRAILLE
LOCATION
SINGLE DOOR:
MOUNT ON LATCH SIDE OF DOOR
DBL DOOR - 1 ACTIVE LEAF:
MOUNT ON INACTIVE LEAF.
DBL DOOR - 2 ACTIVE LEAVES:
INSTALL ON RIGHT SIDE OF RIGHT
HAND DOOR
MEN WOMEN
UNISEX RESTROOM
MEN
HANDICAPPED
ACCESSIBLE
RESTROOM
TO
B
O
TT
O M
O F
R
AI
SE
L
ET
TE
R
IN
G
" M
IN
" M
AX
SEE CLEAR FLOOR AREA GRAPHIC
CL
18"MIN
" M
IN
CLEAR FLOOR AREA, CENTERED ON RAISED
CHARACTERS, OUTSIDE OF DOOR SWING
TO
B
AS
EL
IN
E
O F
BR
AI
LL
E
" M
IN
" M
AX
APPROVED STAIRWAY IDENTIFICATION SIGNS SHALL BE LOCATED AT EACH
FLOOR LEVEL IN ALL ENCLOSED STAIRWAYS IN BUILDINGS TWO OR MORE
STORIES IN HEIGHT. THE SIGN SHALL IDENTIFY THE STAIRWAY, ROOF
ACCESS, FLOOR LEVEL AND UPPER & LOWER TERMINUS OF THE STAIRWAY
CORRESPONDING GRADE 2
BRAILLE TO BE LOCATED
DIRECTLY UNDER OR
ADJACENT TO SIGNAGE
INFORMATION
TO
B
O
TT
O M
O F
R
AI
SE
D
L
ET
TE
R
IN
G
" M
IN
-6
0" M
AX
SEE CLEAR FLOOR AREA GRAPHIC
CL
O R
T O
B A
S E
LI
N
E O
F B
R A
IL
LE
5"MAX.
15"MIN.
8"MIN.
9" M
IN
"M
IN
W H
EE
L
C H
AI
R
"M
AX
11"MIN.
"M
IN
52"MIN
CLEAR FLOOR SPACE
CONTROLS AT OR
NEAR FRONT EDGE
CANTILEVERED DRINKING FOUNTAIN & WATER COOLERS
W H
EE
L
C H
AI
R
" M
AX
ST
AN
D
IN
G P
ER
SO
N
3"
IF
IN
SI
D
E
AL
C O
VE
"M
IN
RECEPTACLE
OUTLET
UNOBSTRUCTED
THERMOSTAT
UNOBSTRUCTED
SWITCH
RECEPTACLES AND SWITCH MOUNTING HEIGHTS
UNOBSTRUCTED FIRE
ALARM PULL BOX
"M
IN
.36
"M
IN
"M
AX
"M
AX
FIRE EXTINGUISHER
148" M
IN.
BUILT UP TO CURB RAMP
RETURNED CURB
PLANTING OR OTHER
NONWALKING SURFACE
48" M
IN.
FLARED SIDES
NOTE:
IF x<48", THEN SLOPE OF THE FLARED
SIDES SHALL NOT EXCEED 1:12
x
NOTE:
(1) SLOPE = Y / X WHERE X IS A LEVEL PLANE
(2) COUNTERSLOPE SHALL NOT EXCEED 1:20
MEASUREMENT OF CURB RAMP SLOPES
RUNNING SLOPE
1:20 MAX
RUNNING SLOPE 1:12
MAX COUNTERSLOPE
1:20 MAX
WALK
CURB RAMP STREET
x y
RUNNING SLOPE
1:12 MAX
1 1/4" MAX TO 2" MAX
OUTSIDE DIA. PIPE
HANDRAIL
CONCRETE SIDEWALK
AND RAMP
BOTTOM AND TOP HANDRAIL EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE
LANDING SURFACE, OR BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN.
W
AL
KI
N
G S
U R
FA
C
E
G R
IP
P
IN
G
S U
R
FA
C E
8"
A B
V
12" MIN
12" MIN
4" M
AX
RAMP LENGTH; SEE PLANS
12"MIN.
CONCRETE SIDEWALK
AND STAIRS
X = TREAD DEPTH (11" MIN)
1 1/4" MAX TO 2" MAX
OUTSIDE DIA. PIPE
HANDRAIL
1-1/2" MAX OVERHANG, OR 30° MAX ANGLE
X X
1/2" MAX. RADIUS, OR
1/2" MAX 45° BEVEL
4"
7"
N O
SE
O
F
ST
AI
R
8"
A
BV
BOTTOM AND TOP HANDRAIL EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE
LANDING SURFACE, OR BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT.
VERTICAL RISER
BEVELED NOSING
VERTICAL RISER
CURVED NOSING
1 1/2" MAX
4" M
IN
-7
"M
AX
NOSINGS THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED
OR BEVELED
BEVELED
1 1/2"MAX
30°MAX
CURVED
1 1/2"MAX
11"MIN11"MIN
1/2" MAX ROUNDED
1/2" MAX BEVEL
45°
ENLARGED
BEVELED NOSING
ENLARGED
RADIUS NOSING
PROVIDE VISUAL CONTRAST TO ALERT
THE VISUALLY IMPAIRED, SHALL BE OF
CONTRASTING COLOR FROM STAIR TREAD
OF DARK-ON-LIGHT OR LIGHT-ON-DARK.
CONTRAST SHALL BE AS SLIP RESISTANT
AS STAIR TREAD
TYP STAIR TREAD
2"
CLEAR
1/4"
CLEAR
1 1/2"
RETURN METAL
HANDRAIL TO WALL
@ TOP & BOTTON
OF STAIR
1 1/2" O.D. STEEL
PIPE HANDRAIL
FINISH WALL;
SEE PLANS FOR
WALL TYPE
AT CONCRETE & MASONRY WALL; RE: WALL TYPES
1 1/2" 1 1/2"
1/
2"
TO
W
AL
KI
N G
S U
R
FA
C E
" M
IN
. T
O
8" M
AX
RETURN METAL HANDRAIL TO
WALL @ TOP & BOTTOM OF RAMP
1 1/2" O.D. STEEL PIPE HANDRAIL
3" DIAMETER STEEL MOUNTING
PLATE @ 4'-0" O.C. WITH (2)
EXPANSION BOLTS
FINISH WALL; SEE PLANS FOR
WALL TYPE
(4 1/2" MAX)
3"
PRIMTED AND PAINTED COLOR
AS SELECTED BY ARCHITECT
T
CR H IT
E
A
IC
E
L
NS E D
C
O UT
HS
TE
TA
F
A
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
DFCM APPROVAL
123456
E
D
C
B
A
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© ARCH NEXUS All Rights Reserved
STAMP
D F
C M
P R
O J E
C T
N O
05-15-26
STEPHEN M.
No. 7655609-0301
SPRINGER
/2
/2
:1
:1
P
M
A u to d e sk
D o c s:
U T
N G
C W
B
R e m o d e l_ r2
/A R
C H
_2
-U
T N
G C
W B
R e m o d e l_
.r v t
ACCESSIBILITY
COMPLIANCE
AN
S R e d w o o d
R d
B lu ff d a le
U
T
U T
A H
N A
T
IO
N A
L G
U A
R D
25062
05.15.2026
PERMIT SET
GI701
AN
C A
M P
W
IL
L
IA
M S
B U
IL
D
IN
G
R E
M O
D E
L
3/8" = 1'-0"GI701
A2 ADA TURNING AREAS
6" = 1'-0"GI701
A1 CHANGES IN LEVEL
3/8" = 1'-0"GI701
A4 MANEUVERING CLEARANCES
3/8" = 1'-0"GI701
B2 MOUNTING HEIGHTS
3/8" = 1'-0"GI701
B4 URINALS & WATER CLOSETS
3/8" = 1'-0"GI701
C1 ACCESSIBLE SINKS
3/8" = 1'-0"GI701
C3 ACCESSIBLE 3x3 SHOWER STALL
3/8" = 1'-0"GI701
C5 TRANSFER SHOWER & SEAT
3/8" = 1'-0"GI701
D3 SIGNAGE
3/8" = 1'-0"GI701
A6 DRINKING FOUNTAIN DETAIL
3/8" = 1'-0"GI701
B5 MISC. MOUNTING HEIGHTS
3/8" = 1'-0"GI701
E4 CURB RAMPS
3/8" = 1'-0"GI701
E5 EXTERIOR RAMP RAILING
# Date Revision
3/8" = 1'-0"GI701
E6 EXTERIOR STAIR RAILING
3/4" = 1'-0"GI701
D5 TYPICAL STAIR TREAD
3" = 1'-0"GI701
D6 TYPICAL WALL-MOUNTED HANDRAIL DETAIL
UP
02:ES1
02:SW3
02:ES1
9'
0" 7'
0"
6' - 0" +/- 16' - 0" F.V.
31:CS1
03:HP1
1" / 1'-0"
1"
1' -0
MAX
M A
X
6' - 0" 1' - 0" 15' - 6" 5' - 0"
4" TYP
TYP
4' - 4"
4"
5'
6" 5'
6"
1'
0"
+/- 8' - 4" F.V.
5'
0"
- 6
0" F
.V
5' - 0"5' - 0"
- 6
0" F
.V
03:SS1
03:SS1
03:SS1
03:SS1
C8
C8
C8
C8
A2
AE501
SIM
A2
AE501
SIM
A2
AE501
SIM
AS101
A6
TYP.
02:EL1
TYP.
02:EL1
32:CT1
D
02:ES1
02:ES1
- 1
2'
0" F
.V
+/- 8' - 5" F.V.
+/- 17' - 2 1/2" F.V.
- 4
" F .V
02:CT1
02:DC2
02:DC2
02:DC2
02:DC2
+/- 4' - 6" F.V.
- 6
0" F
.V
+/- 5' - 6" F.V.
- 6
0" F
.V
+/- 8' - 4" F.V.
02:AP1
02:DS1
D
A. FIELD VERIFY ALL EXISTING CONDITIONS AND
THEIR COMPATIBILITY WITH NEW
CONSTRUCTION. COORDINATE DISCREPANCIES
WITH ARCHITECT PRIOR TO THE
COMMENCEMENT OF WORK.
B. PLAN WALL DIMENSIONS ARE TO GRID LINE OR
FACE OF WALL STRUCTURE, UNLESS NOTED
OTHERWISE. "CLEAR" DIMENSIONS ARE TO FACE
OF WALL FINISH.
C. SEE STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS FOR MORE
INFORMATION.
D. SEE GI SERIES SHEETS FOR WALL TYPES AND
TYPICAL ACCESSIBILITY CLEARANCE AND
COMPLIANCE REQUIREMENTS, REGULATORY
PLAN INFORMATION; INCLUDING RATED
ASSEMBLY EXTENTS, OCCUPANCY AND EGRESS
SYSTEMS, AND RAILINGS.
E. WHERE NEW CONSTRUCTION INTERFACES
WITH EXISTING, PATCH AND REPAIR AS
NECESSARY TO MATCH ORIGINAL CONDITION.
F. WHERE PROVIDED, DOOR AND WINDOW
DIMENSIONS ARE TO EDGE OF OPENING.
OPENING DIMENSIONS ARE NOMINAL.
CONTRACTOR SHALL COORDINATE DIMENSIONS
OF ALL ROUGH OPENINGS AND ACTUAL FRAME
SIZES.
G. WHERE DOOR LOCATIONS ARE NOT
DIMENSIONED, SEE DETAILS REFERENCED IN
DOOR SCHEDULE BY SPECIFIC CONDITION.
OTHERWISE, THE HINGE SIDE OF DOOR ROUGH
OPENINGS SHALL BE LOCATED 4" FROM THE
ADJACENT PERPENDICULAR WALL, SUBJECT TO
MAINTENANCE OF REQUIRED ADA CLEARANCES
REFERRED IN THE GI700s SHEET SERIES.
H. RESTORE ANY EXISTING SITE TO REMAIN
DISRUPTED BY CONSTRUCTION TO ORIGINAL
CONDITION.
I. DO NOT SCALE DRAWINGS.
GENERAL NOTES - SITE PLANS
D
D
A2
AE501
7'
2" 1'
7'
0"
6' - 0" +/- 16' - 0" F.V.
5'
3/
4" 5'
6"
1'
0"
TYP.
4"
TYP.
4' - 4"
TYP.
4"
4'
0"
31:CS1
4" 5' - 8" 1' - 0" 15' - 6" 4' - 8" 4"
03:SS1
1" / 1'-0"
1"
1' -0
MAX
M A
X
C8
FLOOR MOUNTED HANDRAIL; SEE GI701
FOR HANDRAIL REQUIREMENTS
WALL MOUNTED HANDRAIL; SEE GI701
FOR HANDRAIL REQUIREMENTS
100A
MATCH ELEVATION OF
EXISTING SIDEWALK
MATCH ELEVATION OF NEW
ENTRY DOOR
FIELD VERIFY RAMP LENGTHS REQUIRED TO
PROVIDE MAX. 1" / 1'-0" SLOPE FROM DOOR TO
EXISTING SIDEWALK
C
LE
AR
4'
1/
2"
T
CR H IT
E
A
IC
E
L
NS E D
C
O UT
HS
TE
TA
F
A
DATE:
DRAWN BY:
CHECKED BY:
NEXUS PROJ. #:
DFCM APPROVAL
123456
E
D
C
B
A
Architectural NEXUS, Inc.
2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 http://www.archnexus.com
Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.
© ARCH NEXUS All Rights Reserved
STAMP
D F
C M
P R
O J E
C T
N O
05-15-26
STEPHEN M.
No. 7655609-0301
SPRINGER
/2
/2
:1
:1
P
M
A u to d e sk
D o c s:
U T
N G
C W
B
R e m o d e l_ r2
/A R
C H
_2
-U
T N
G C
W B
R e m o d e l_
.r v t
ARCHITECTURAL
SITE PLAN
KM
S R e d w o o d
R d
B lu ff d a le
U
T
U T
A H
N A
T
IO
N A
L G
U A
R D
25062
05.15.2026
PERMIT SET
AS101
SS
C A
M P
W
IL
L
IA
M S
B U
IL
D
IN
G
R E
M O
D E
L
KEYNOTE SCHEDULE
02:AP1 EXISTING ASPHALT PARKING TO REMAIN;
PROTECT IN PLACE; RESTORE TO EXISTING
CONDITIONS IF DAMAGED
02:CT1 EXCAVATE TO EXTENT REQUIRED TO PROVIDE (2)
4" CONDUITS TO BUILDING 20. SEE BUILDING 20
DRAWING SET FOR COMMUNICATION TOWER
CONNECTION
02:DC2 DEMOLISH PORTION OF EXISTING SIDEWALK IN
PREPARATION FOR NEW STRUCTURAL STOOP;
CONTRACTOR TO FIELD VERIFY EXACT SIZE AND
DEPTH OF SLAB
02:DS1 DEMOLISH EXISTING SPRINKLER HEAD AND
PIPING BACK 2', CAP. REPLACE SOIL FILL
02:EL1 RESTORE SURROUNDING AREA TO MATCH
EXISTING CONDITIONS WHERE DISRUPTED BY
CONSTRUCTION; ADJUST IRRIGATION SYSTEM
AFFECTED BY NEW SIDEWALKS
02:ES1 EXISTING SIDEWALK TO REMAIN. PROTECT IN
PLACE
02:SW3 MATCH EXISTING SIDEWALK ELEVATION
03:HP1 EXTEND CONCRETE AS NEEDED FOR MECHANICAL
UNIT HOUSE KEEPING PADS (MIN. 4" THICK, SEE
MFTR REQ.); COORDINATE WITH MECHANICAL
EQUIPMENT; ENSURE EQUIPMENT DOES NOT
RESTRICT SIDEWALK WIDTH
03:SS1 STRUCTURAL STOOP AT EGRESS DOOR; PROVIDE
FOUNDATION WALL DOWN TO FROST LEVEL
AROUND PERIMETER OF CONCRETE LANDING;
SEE EXTENT ON AS101; SEE ALSO C2/A501 AND
STRUCTURAL DRAWINGS
31:CS1 CRUSHED STONE TO MATCH EXISTING
SURROUNDING LANDSCAPE
32:CT1 RESTORE SITE TO EXISTING CONDITIONS AFTER
INSTALL OF COMMUNICATION TOWER
CONNECTION LINES
1/8" = 1'-0"AS101
A4 ARCHITECTURAL SITE PLAN
1/8" = 1'-0"AS101
C4 ARCHITECTURAL SITE DEMO PLAN
# Date Revision
SITE CONCRETE DEMOLISHED: +/- 240 SF
NEW CONCRETE: +/- 395 SF
1/4" = 1'-0"AS101
A6 ENLARGED SITE PLAN - ENTRANCE
+/- 8' - 5" F.V.
1.
2.
3.
4.
5.
6.
7.
8.
9.
GENERAL NOTES: THESE GENERAL STRUCTURAL NOTES DO NOT SUPERSEDE THE
PROJECT SPECIFICATIONS, BUT ARE INTENDED TO BE COMPLIMENTARY TO THEM.
CONSULT THE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS IN
EACH SECTION. NOTATION AND SPECIFIC DETAILS ON THE DRAWINGS TAKE
PRECEDENCE OVER THESE NOTES AND TYPICAL DETAILS.
CONTRACT DRAWINGS: THE PRIME CONTRACT DRAWINGS ARE THE
ARCHITECTURAL DRAWINGS. THESE STRUCTURAL DRAWINGS ARE
SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. ALL OMISSIONS OR
CONFLICTS, INCLUDING DIMENSIONS, BETWEEN THE VARIOUS ELEMENTS OF THE
STRUCTURAL DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH ANY WORK
INVOLVED. IN CASE THERE IS A CONFLICT BETWEEN DRAWINGS, FOLLOW THE
MOST STRINGENT REQUIREMENT, SUBMIT A REQUEST FOR INFORMATION, AND/OR
PROCEED AS DIRECTED BY THE ARCHITECT WITHOUT ANY ADDITIONAL COST TO
THE OWNER. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF
SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK.
STRUCTURAL DRAWINGS: THESE STRUCTURAL DRAWINGS SHALL BE USED IN
CONJUNCTION WITH THE ARCHITECTURAL AND OTHER CONSULTANT DRAWINGS.
ONLY THE PRIMARY STRUCTURAL ELEMENTS AND SYSTEMS ARE INDICATED
WITHIN THESE STRUCTURAL DRAWINGS. ALL STRUCTURAL DETAILS ARE
REPRESENTATIVE IN NATURE AND ARE NOT TO BE SCALED FOR ANY REASON.
MANY OTHER ELEMENTS SUCH AS, ARCHITECTURAL LAYOUTS, ELEVATIONS,
SLOPES, DEPRESSIONS, CURBS, MECHANICAL/ELECTRICAL EQUIPMENT,
EXTERIOR LIGHT GAUGE FRAMING, STAIRS, ETC. ARE GENERALLY NOT SHOWN IN
THESE STRUCTURAL DRAWINGS. IT IS INTENDED THAT ALL SHOP DRAWINGS AND
DETAILING OF STRUCTURAL ELEMENTS WILL REQUIRE INFORMATION FROM ALL
CONTRACT DOCUMENTS, NOT JUST THESE STRUCTURAL DRAWINGS.
PROJECT COORDINATION: IT IS THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR TO COORDINATE ALL ITEMS WITH ALL TRADES TO INSURE THERE
ARE NO CONFLICTS BETWEEN OTHER TRADES AND THE STRUCTURAL ELEMENTS.
ANY OPENINGS, PENETRATIONS, OR ATTACHMENTS TO ANY STRUCTURAL
ELEMENT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SHALL BE
COORDINATED WITH THE ARCHITECT/ENGINEER.
SUBMITTALS: STRUCTURAL SUBMITTALS SHALL ONLY BE SUBMITTED TO THE
STRUCTURAL ENGINEER FOR REVIEW AFTER THE GENERAL CONTRACTOR HAS
REVIEWED AND APPROVED THE SUBMITTAL. CONTRACTOR SHALL ALLOW AT
LEAST 10 BUSINESS DAYS (2 WEEKS) FOR EACH SUBMITTAL TO BE REVIEWED. IF
AN ITEM IS SUBMITTED WHILE ANOTHER SUBMITTAL IS UNDER REVIEW, THE 10
DAY REVIEW PERIOD FOR THAT NEWLY SUBMITTED ITEM DOES NOT BEGIN UNTIL
THE PREVIOUS SUBMITTAL IS COMPLETE. THE SHOP DRAWING REVIEW PROCESS
SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY OF COMPLETING
THE PROJECT ACCORDING TO THE CONTRACT DOCUMENTS, REGARDLESS OF
INFORMATION SHOWN IN THE REVIEW COMMENTS. SHOP DRAWINGS MADE FROM
REPRODUCTIONS OF THESE STRUCTURAL DRAWINGS WILL BE REJECTED.
SHORING AND BRACING REQUIREMENTS: THE STRUCTURAL SYSTEMS SHOWN IN
THESE DRAWINGS SHALL NOT BE CONSIDERED STABLE UNTIL ALL STRUCTURAL
ELEMENTS ARE IN PLACE AND COMPLETED.
This is the start of the file's text. The full file is on GovTribe.