Amendment 0004.pdf

PDF 13 MB Posted

Attached to
Department of State - 3rd Floor Office Build-Out, Detroit, MI
Solicitation number
47PF0021R0002_
Issued by

About this file

This solicitation is for renovation services at the Department of State building in Detroit, Michigan. The General Services Administration seeks to renovate approximately 18,228 square feet of the third floor to convert it into modern office and transaction spaces for the Department of State's Passport Services. Renovations will include construction of new walls, furniture partitions, and finishes. Mechanical, electrical, plumbing and fire protection systems must be upgraded. Acoustic improvements are required for the gym located on the fourth floor. The selected contractor will provide all management, labor, equipment, and supplies to complete the project, which includes renovating restrooms to better serve employees and the public.

View the file

Other files

File Type Posted
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001...pdf PDF
RFP 47PF0021R0002.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

����
������������������������ !"#$%&�� �'�$%�!()*�+#&,-.&*/�/���&�

%&(&"0&,�!/�/1&�2#!(&�,&3"-*!/&,� �%�/1&�%&(&"2/�� �� &%3�2%"�%�/��/1&�1�$%�!*,�,!/&�32&(" "&,�.!'�%&3$#/�"*�%&4&(/"�*�� �'�$%�� &%���"��

���5������

�������
������������������������

5������

��
��������������
����
����������������������������

��5������

67889:;<=>?@>A88( ����� �����B�������

?:6@C:6@>8<D8E<F9G9>?>9<@H:<C9D9G?>9<@8<D8G<@>=?G>

I���!.&*,.&*/J.�," "(!/"�*�*$.�&% K���& &(/"0&�,!/& L���%&M$"3"/"�*J2$%(1!3&�%&M$"3"/"�*�*$.�&% ����2%�4&(/�*$.�&%�NOPQRSSTUVRWTXY

Z���!,."*"3/&%&,��'�NOPQ[\]X̂Q\]R_QO\X̀ QaY (�,&

E>?@C?=C8D<=:8bc8d=6e78ffHgcfhi8 2���

���������-3!� !%��L��( %���K�ILK

�j!���!.&*,.&*/�� �3�#"("/!/"�*�*$.�&% j����,!/&,�NkllQOmlnQooY

�p!���.�," "(!/"�*�� �(�*/%!(/J�%,&%�*$.�&%

�p����,!/&,�NkllQOmlnQoqY ff788>r9E89>6:8<@Fs8?;;F96E8><8?:6@C:6@>E8<D8E<F9G9>?>9<@E

5������������

����
�������������������

�������"�����L���/���� �������� ����t�������� ���� ���t��������

�I���!((�$*/"*-�!*,�!22%�2%"!/"�*�,!/!�NOPQ̂XuvÛXwY

������ ��������x��������

��������������x fb788>r9E89>6:8?;;F96E8<@Fs8><8:<C9D9G?>9<@E8<D8G<@>=?G>EH<=C6=E78 9>8:<C9D96E8>r68G<@>=?G>H<=C6=8@y:z6=8?E8C6EG=9z6C89@89>6:8f{7

(1&()��*& !���/1"3�(1!*-&��%,&%�"3�"33$&,�2$%3$!*/�/����NkSXVUP|QRv\][̂U\|Y�/1&�(1!*-&3�3&/� �%/1�"*�"/&.��L�!%&�.!,&�"*�/1&�(�*/%!(/��%,&%��� ������*$.�&%�"*�"/&.��p!�

����/1&�!��0&�*$.�&%&,�(�*/%!(/J�%,&%�"3�.�," "&,�/��%& #&(/�/1&�!,."*"3/%!/"0&�(1!*-&3�N}vV]QR}QV]R_~X}QU_QSR|U_~Q[PPUVX�� QQQQQQRSŜ[ŜUR\U[_QwR\R�QX\V���3&/� �%/1�"*�"/&.��L��2$%3$!*/�/��/1&�!$/1�%"/'�� � !%�LK��pK����

(���/1"3�3$22#&.&*/!#�!-%&&.&*/�"3�&*/&%&,�"*/��2$%3$!*/�/��!$/1�%"/'�� �

,����/1&%QNkSXVUP|Q\|SXQ[PQ̀[wUPUVR\U[_QR_wQRv\][̂U\|Y

&t

��������
5�������������������������

������"����j!� ���p!�� �������

����������������
������������������

��(���,!/&�3"-*&, ��!���*!.&�!*,�/"/#&�� �3"-*&%�Nm|SXQ[̂QŜU_\Y

��(���,!/&�3"-*&, ��!���*!.&�!*,�/"/#&�� �(�*/%!(/"*-�� "(&%�Nm|SXQ[̂QŜU_\Y

�L���,&3(%"2/"�*�� �!.&*,.&*/J.�," "(!/"�*���̂~R_U�XwQW|Q���Q}XV\U[_Q]XRwU_~}�QU_VTvwU_~Q}[TUVU\R\U[_�V[_\̂RV\Q}vW�XV\Q̀R\\X̂Q�]X̂XQPXR}UWTX�Y

2!-&������� ����2!-&3

����"33$&,��' (�,&

����*!.&�!*,�!,,%&33�� �(�*/%!(/�%�N�v̀ WX̂�Q}\̂XX\�QV[v_\|�Qk\R\XQR_wQ�O�Q�[wXY ���

������(�*/%!(/�%J� &%�%

NkU~_R\v̂XQ[PQSX̂}[_QRv\][̂U�XwQ\[Q}U~_Y

������$*"/&,�3/!/&3�� �!.&%"(!

NkU~_R\v̂XQ[PQ�[_\̂RV\U_~Q�PPUVX̂Y

�̂X�U[v}QXwU\U[_Qv_v}RWTX

ª«��¬����¤®¢¤¦�¬�¤���̄��¢¢£�«��� �§��̈¢̄�°±�²�²���

ª«��¬����¤®¢¤¦�¬�¤���̄��¢¢£�«��� �§��̈¢̄�°±�²�²���

�³�́ ��ªµ����ª

�³�́ ��ªµ����ª µ ¶² µµ·��·ª�ª� µ�·�̧·ª�ª� µ

��������� ���.���0���+����+-

�����1�)2������3��+ ��,-�

)4, )1, )5, )6, 7��� ���!���� ����� ���+����&��� �0����+��&� ��� +������� ��3���� �0�&������������3��+ ��� �� �0����+��&���� +������� ��3���� �0�-

7��� ���$$!����� !� 0�������&������������3�� + ����� !!�.������+ ��� 0���+����.%������ ����� ����0�$ �����-

7��� ���+���� ����������+� �� ������� !���� ���������0����������������� ������������� ���3���������������8�3�������&������������3��� ���������0���������� !!�.������� ��� ������ �������3��+ ��� �+���+���� ��������.����������

7��� ���+���� ��������3�����0� ������� ���������� +�� �!����� ������� ����������������3������������ ����8�3�������&������������3��+ ����� !!�.������� � ��� �������������3��+ ���������������� ���������

7��� ���+���� ��������������0���������� ����0� �������9��+������� ������������ ������+������ ����!��������� ������ ��������� ����&������������3�� + ����� !!�.������� ��� �������������3��+ �������

����������0�������-����� $$!�� .!�&������������ $$��$�� ���������0����������+�����������+��.!��/-

�����<�)� ��� �+�=++������������� ����,-��7��� ����� ����9��� ��&� ++����&� �+���+�� �����'����� �������0�� !������ ��������+��&���!������ �0�+�.%� �������� �$��3�������+���� ����-

* ��+,&� �+�(?&�)@�+���� ������������� ��A��+��� ����������$��+��0�.! �/����������������.��� �+� + �������������0�� !���!���� ����&������ ��&������+��-

�����(4�)=��������0� �+�=$$��$�� �����* � ,-�� B���� $$��$�� ��&���+�� ���������$ ���������� ��+���� ��������� ��� ������+� ��������0� �! ������ �����.%���������0��������������!!�'��0�

)4,=��������0��! ������ ����� ����+���� ������������������������C

���!�+����.D����� �����������������!����� ��!���� ����A����� ���'������� ��.!�-

�����(:;-����������� ����0��������9����0� ������������� ��E����+������!���� ����� ���+�����-������ ����� ����0��������9����0� ������������ !!%� ���#�+�! ��� �����$$!����� !� 0��������-

���2������������ ����� �0��������!��$!�� ��������0�� �! ������ �������� ��� �����.��$! ��+����.!��/�(4&�� ������� �� ������/� �+�����'��+��F����������� ����� �����F-

�����(1-������/����� $$��$�� ���.�#������+�� ������� �%$�������+���� ����-����������������������$��+��0� �����+-������/�'������������������� ������������0�� �����+�������-��)����7=��51-(?1-, �����(5�)*�����$��������=���+����A@�+���� ����,-

��0 ��G�� ���+�����������+���� ��������+��� ���� $$��$�� ���������������� ���7��� ��)��7,� ���������� +��0����������� $$!�� .!�� ��!���� ������������� ��-��������7�� .!����� ��������&���'�3��&��� !!�����.��������������������

�3�� !!���� !������ ���$�����.%���������0�������� ������!!�'��0����������� )�,���� !������ ���$���������� ��+�.%�C�� )��,���� !������ ���$�����+���� ��+�.%�C�� )���,���� !������ ���$��������� �0�+-

B��������3��0&������� ���0&���� ++��0����+�&� �+�����%���������� ��������� �+� ��������0�

)0, B���������7�1?�������+�������!���� � +������� �����.%���������� ����0���������������� ������ ��+������������3��������������� 8�3�������&���������%���������(5�������� )�,���=������������������!������+������� ����H� �+�

)4, )1, )5, )6, IJKLMKNMOPQNROSTO)�2U-�((A4?(:,OVKWX

)(,=��������0��! ������ ���� ��������� ���������������������C

Description of Amendment

RFP 47PF0021R0002

DOS 3rd Floor Office Build-Out PV McNamara Federal Building 477 Michigan Avenue Detroit, Michigan 48226 Amendment 0004

Amendment 0004 is issued to:

1. Address RFIs received for the DOS 3rd Floor Office Build-Out, PV McNamara Federal Building. The Answers provided in the attached supersede any inconsistent provisions contained in the solicitation.

2. Provide revised specifications.

3. Provide the attendance list and address questions asked during the second site visit walk-through held on October 27, 2020.

All other solicitation terms and conditions remain unchanged.

PLEASE NOTE – YOU MUST SIGN THE SF30 INCORPORATING THIS

AMENDMENT IN BOX 15a AND RETURN THE SIGNED FORM ALONG WITH

YOUR PROPOSAL.

g.h. forbes associates 28000 Woodward Ave, Ste 202, Royal Oak, MI 48067 www.ghfaa.com 248.542.7866

PVM – DOS 3rd Floor Office Build-Out Passport Services

PCN: RMI12446

G.H. Forbes Associates Architects Amendment #0004 11/03/2020

The following questions were emailed to the project team. Answers are indicated below in red:

1. Who is responsible for LEED certification costs? The LEED cost is the responsibility of GSA. G.H.

Forbes Associates Architects will be the LEED Project Administrator. The general contractor is to engage a LEED Coordinator to coordinate LEED requirements and points to be gained in construction as noted in specification 01 81 13.17, section 1.7.

2. Is a LEED certification required? Yes, LEED Silver is required per Specification 01 81 13. Section VI.F of the RFP 47PF0021R0002, Non-Price Factors, Factor 2: Qualifications and Experience of Key Personnel, is amended to add LEED Coordinator and Waste Management Coordinator to the list of key team members. The awardee must use the personnel identified in its proposal. Any substitutions must be personnel of equal experience and qualifications and must be specifically approved by the Contracting Officer.

3. Based on the General Note on Sheet A-101 #11 “Install Ballistic level protection 1 at all walls between Public Seating 305 and all adjacent tenant rooms” – are there any material installation requirements that are not shown in the wall type details or on the drawings in some location?

All information is included in the wall types and in the enlarged floor plan. Refer to details on pages A-301 thru A-304 and A-401. Per General Note 14 Install ballistic material with batten strips at seams or butt joints.

4. Is there a specification for “Snowsound Acoustic Panels”? The Snowsound Acoustic Panel properties are noted on Drawings A-203 and A-307. There is not a specification section for the Snowsound Panel. Refer to product data attached for additional information. An approved equal to this product could be considered during the shop drawing phase of the project.

5. Is Thermolite the only acceptable option for the exterior window work? Although Thermolite is the manufacturer and installer of the windows, they are not the only contractor that can perform the work to remove and reinstall the storm windows. It is highly recommended to utilize their services when relocating blind controls.

6. Room #308 UPO Lockers show a 60” bench. Is this to be supplied and installed by the contractor?” Is there a specification for this bench? Yes, the benches included in UPO Lockers 308 and Coats and Lockers 348 are to be provided and installed by the general contractor. Refer to keynotes on the drawings and specification 10 51 13.

7. Sheet A-401 detail 1 Enlarged Plan of Adjudication Counters and Acoustical Soffit Above identified a Roller Shade Sheerwave SW2500. Research shows this product is manufactured by a company called PHIFER. PHIFER is not listed in the specification section 12 24 13 as an acceptable manufacturer. Please clarify. The basis of design for the roller shades is Sheerwave SW2500 as indicated on the drawings. The specifications have been updated accordingly.

8. In section 01 10 00 states: Contractor’s Required Work During Unoccupied Hours (5:00 PM to 7:00 AM) shall be at no additional expense to the Owner. The Contractor is responsible to pay all Building O&M Contractor feeds required to perform the work under this contract. The O&M Contractor’s hourly rate is $63.33/hr. for regular time and $90.66/hr. for overtime. Please confirm whether that means any work done during this period (5:00 PM to 7:00 AM) the contractor must pay this fee. Are there any minimums to this fee? Are certain hours considered overtime or is that only if the contractor works more than 8 all outside normal hours? No, the contractor will only be required to pay for this additional fee when O&M services are required during the hours of 5:00 PM to 7:00 AM. There are no minimum fees. Overtime is in effect from

6:00 PM – 6:00 AM.

9. Please clarify who contracts / pays for the commissioning agent (CxA). The CxA noted in Specification 01 91 13 will be provided by GSA. The contractor is responsible for the costs to provide information and perform any commissioning in the contract documents to facilitate efforts of the CxA provided by GSA.

10. Is there a performance requirement regarding the transmission of noise from the 4th floor gym?

Db reduction or acceptable noise level on the 3rd floor? OSHA noise exposure limits? Acoustic performance is considered in the design of the drywall barrier lid, sound masking system and modifications to the 4th floor gym floor and equipment. Product submittals and installation will be reviewed during construction. Acoustic measurements are not currently planned after construction.

11. Is there a specification for the signage? There is no dedicated specification, but all the specification information for all signage is included on Drawings A-108 and A-602.

12. Per coded note 15 on page AD 101 and coded note 2 on A 101, will the windows be existing? If the only requirement is for an interior film to be applied to the window, why is it required that they be removed and salvaged until re-installment? The building’s windows are existing, and they are storm windows. The ballistic film is to be installed on the interior side of the exterior windows. The storm portion of the window must be removed to allow for installation of the film on the interior side of the exterior window.

13. Per coded note 2 on page A 101, Thermolite is mentioned as the contractor to remove and re-install the windows. If this is the case will they be used for all glazing / window matters on the project? Would that bid package be allowed to be solicited to our sub base, or do we have to use Thermolite? Refer to response to items 5 and 12 above.

14. "VI.G. Evaluation of Joint Venture Offerors: In addition to, and notwithstanding the foregoing or any other contrary provision herein, the Government will only consider past performance information submitted for work performed by the joint venture (including joint ventures established through the 8(a) Business Development Mentor-Protégé Program). The Government will not consider past performance information for work performed individually by each firm in the joint venture (including joint ventures established through the 8(a) Business Development Mentor-Protégé Program)." If a Joint Venture Offeror has not completed 5 projects together, could the joint venture projects, completed together, be submitted along with additional projects completed by each individual joint venture company, meeting the same minimum relevance requirements, be submitted/considered to meet the maximum of 5 projects/references in Factor 1 Past Performance? It is not possible for Joint Venture Offerors to submit 5 projects completed by the Joint Venture as the SBA only allows 3 awards to each joint venture company? No. Note that five references are the maximum the Government is required to review. There is no minimum number.

15. Does this project have a PLA Agreement? Will this be a Union Job? No. Davis Bacon rates apply as well as any relevant terms included in the solicitation.

The following substitution requests were emailed to the project team. See information below:

1. The Substitution Request for the use of ASI Global Partitions and ASI Accurate Partitions 64” tall with Ultimate Privacy has been approved. Find attached information below.

2. The Substitution Request for use of the Schonox HA waterproofing membrane for tiling has been approved. Find attached information below.

3. The Substitution Request for the use of ThermalStar X-Grade thermal insulation for extruded polystyrene board has been approved. Find attached information below.

4. The product performance for the Substitution Request for the ASI Storage Solutions Benches is equal, but it is unclear if the specified dimensions can be achieved. If the specified dimensions indicated in the contract documents could be achieved, this would be acceptable.

5. Due to the lack of information for the Substitution Request for use of the ASI Storage Metal Lockers, it cannot be determined if the product is an approved equal and therefore the substitution request has not been approved.

6. Subject to compliance with the Specification 08 56 63 requirements, including 2.1 Performance Requirements for Regional Materials, Sweeper’s Metal Fabricator’s Corporation is an approved manufacturer.

The following specifications have been reissued with revisions. Revisions are indicated in the specifications with bold text:

1. Specification 06 10 53 – Preservative-treated wood was removed from the specification.

2. Specification 09 22 16 – Armstrong Axiom Drywall trim was added to the specification. Added requirement for shop drawing of curved ceiling soffit in Public Seating 305.

3. Specification 09 91 23 – Light Reflectance Factor information was updated in the specification.

4. Specification 12 24 13 – Basis of Design manufacturer was updated in the specification.

5. Specification 26 09 43 – Lighting Control Systems specification has been added to the project.

The pre-proposal site visit meeting report from 10/27/2020 has been included in this Amendment. This report states the contractors who attended, questions that were asked, and a few photos.

END

16. We see in the specs that the Commissioning organization is going to be chosen by the GSA, but are not clear as to whether G.H. Forbes is going to be the LEED Project Administrator or not. We have done many LEED projects as the Project Administrator, and have also done others where we are simply an adviser to the GC to make sure they follow everything so they don’t cause the project to lose any points. Obviously, there is a considerable difference in cost. We also did not find the LEED sheet that would show what points are going to be pursued. Did we miss that?

G.H. Forbes Associate will be the LEED Project Administrator for the project. The LEED checklist is included as an attachment to this Amendment as information only per specification 01 81 13.17, section 1.1.A.2.

17. Are there any details for the termination of the drywall barrier lid at the exterior wall? Refer to wall types J and K on the revised drawing A-303 attached for notes on the termination of the drywall barrier lid at the exterior.

18. Can we get the latest fire pump test results for McNamara? See attached document for the fire pump report from September 2020.

19. Upon reviewing the bid docs for this project, I see that the RFP states “Supplemental Information Forms” are to be submitted for relevant projects along with PPQs, but the SIF forms are not provided. Will these be required and provided in an upcoming amendment?

VI.F. Non-Price Factors Past Performance - is amended to delete: "Offerors shall submit the attached Supplemental Information Forms for projects that meet the past performance requirements."

Factor 1: Past Performance of the General Contractor Description: Is amended to delete "and Supplemental Information Forms..."

Offerors remain responsible for obtaining past performance information prior to submission of offers using the Past Performance Questionnaire and Survey as indicated in the RFP.

• Class A fire and smoke safety

(UL 723/ASTM E84)

• CAL 133, 117 pass

• Sleek profile at only 1.4” thick

• Wall mounted

• Tilts and rotates

• Ceiling suspended

• Free standing

• Polyester internal padding with Snowsound technology, polyester covering in Trevira CS® fabric

• Single material and 100% recyclable

• Eco friendly - Greenguard Gold

• Durable, tackable double-sided surface

• Patented variable density composition

• Class A sound absorption with NRC 1.0

(ISO 354/ASTM C423/ISO 11654)

• Absorbs 94% of human speech frequencies

FLAP/ FLAP GRANDE

FLAP/ FLAP GRANDE panels use patented Snowsound® technology to visually and acoustically enhance interior spaces. Designers can configure the uniquely shaped panels in artistic wall or ceiling patterns.

DESIGN: ALBERTO AND FRANCESCO MEDA FLAP / FLAP GRANDE

FLAP 19”x 23” - PANEL ONLY

FLAP GRANDE 26”x 32” - INCLUDES 3” MOUNTING ARM

COLOR

OLIVE

GREEN

40020079

PART #STANDARD

COLORS

STANDARD

COLORS

STANDARD

COLORS

STANDARD

COLORS

COLOR

WHITE

CARROT

ORANGE

CHARCOAL

GRAY

40023007

40023010 40023021

PART #

APPLE

GREEN

BLUE

40023012

40023013

COLOR

RED 40023011

PART # COLOR

BLACK 40023014

PART #

SILVER

GRAY

40023008 SUN

YELLOW

40023009BEIGE 40023006 DOVE GRAY 40023020

FLAP / FLAP GRANDEDESIGN: ALBERTO AND FRANCESCO MEDA

* For direct surface mounting on wall or ceiling, please specify one of the two arms above.

23.6”

16.75”

.7

5”

.75

23.35”

MOUNTING ARMS FOR FLAP PANEL (SIZE 19”x 23” ONLY) Rotates 360

Degrees 8” 3”

4” 9”

32”

22.75”

.5

.5”

31.5”

3”

4” Rotates 360

Degrees

ARM LENGTH PART # QTY FINISH

1400240073” CHROME

1400240088” CHROME

* FLAP GRANDE includes 3 in. Mounting Arm

COLOR

OLIVE

GREEN

40023027

PART #STANDARD

COLORS

STANDARD

COLORS

STANDARD

COLORS

COLOR

WHITE

CARROT

ORANGE

CHARCOAL

GRAY

40023030

40023025

40023031

PART #

APPLE

GREEN

BLUE

40023028

40023029

COLOR PART #

BLACK 40023033SILVER

GRAY

40023022

SUN

YELLOW

40023024

RED 40023026 BEIGE 40023032

DOVE GRAY 40023023

FLAP LED KIT - LED BACK LIGHTING SYSTEM FOR FLAP AND FLAP GRANDE

*ETL Certified

32”

22.75”

.5

.5”

31.5” FLAP GRANDE 26”x 32” - INCLUDES 8” MOUNTING ARM

COLOR

OLIVE

GREEN

40023042

PART #STANDARD

COLORS

STANDARD

COLORS

STANDARD

COLORS

COLOR

WHITE

CARROT

ORANGE

CHARCOAL

GRAY

40023034

40023040

40023037

PART #

APPLE

GREEN

BLUE

40023043

40023044

COLOR PART #

BLACK 40023045SILVER

GRAY

40023035

SUN

YELLOW

40023039

RED 40023041 BEIGE 40023038

DOVE GRAY 40023036

8”

9”

Max 67”

6” x 1”

5.6” x 0.74”

140025093FLAP LED - SINGLE LIGHT

PART # QTY

140025092FLAP LED - 4 LIGHT PACK

5.6” x 0.74”

5” x 1”

Max 63”

- 4 LED 24V.5.6W

- AWM 2464#, 20AWG, 80˚C, 300V x 6.5’

- INPUT: AC 100-240V, 50/60Hz, 230mA

- OUTPUT: DC 24V, 0.42A

- Chip Brand: AAA

- Lumens 550

- Color Temperature: 3000K

*ETL Certified

DESIGN: ALBERTO AND FRANCESCO MEDA FLAP / FLAP GRANDE

Rotates 360 Degrees

* FLAP GRANDE includes 8 in. Mounting Arm

PART # QTY

- LED 24V.5.6W

- AWM 2464#, 20AWG, 80˚C, 300V x 6.5’

- INPUT: AC 100-240V, 50/60Hz, 230mA

- OUTPUT: DC 24V, 0.42A

- Chip Brand: AAA

- Lumens 550

- Color Temperature: 3000K

Flap: 94.5” Flap Grande: 126”

Fl ap

: 3 6.

2” Fl ap G ra nd e:

8.

8”

2.75”

Flap: 49.2” Flap Grande: 65.7”

Fl ap

: 3 6”

Fl ap

G ra nd e:

2”

Flap: 82.6” Flap Grande: 109.4”

Fl ap

: 7 0.

8” Fl ap G ra nd e:

4.

4”

FLAP / FLAP GRANDE PANEL TYPICALS

Fl ap

: 3 6.

2” Fl ap G ra nd e:

8”

Flap: 74.8” Flap Grande: 100”

2.75”

FLAP / FLAP GRANDEDESIGN: ALBERTO AND FRANCESCO MEDA

FLAP / FLAP GRANDE INSTALLATION

EXAMPLE FOR THE USE OF TEMPLATES PROVIDED

WITH FLAP/ FLAP GRANDE

STEP 1 STEP 2

STEP 3 STEP 4

STEP 5 STEP 6

LEED v4 for ID+C: Commercial Interiors Project Checklist PVM DOS 3rd Floor

Date: 9/16/2020 Y ? N

1 1 Credit 2

15 0 21 18 9 1 7 Indoor Environmental Quality 17 18 Credit 18 Y Prereq Required

8 Credit 8 Y Prereq Required 7 Credit 7 2 0 Credit 2

1 Credit 1 2 1 Credit 3 2 Credit 2 1 Credit 1

1 1 0 Credit 2

8 0 4 Water Efficiency 12 1 Credit 1 Y Prereq Required 2 Credit 2 8 0 4 Credit 12 3 Credit 3

1 Credit 1

10 4 24 Energy and Atmosphere 38 2 Credit 2 Y Prereq Required Y Prereq Required 4 0 2 Innovation 6 Y Prereq Required 3 2 Credit 5 0 4 1 Credit 5 1 Credit 1 9 0 16 Credit 25

0 2 Credit 2 3 0 1 Regional Priority 4 3 Credit 3 1 Credit Density and Diversity (threshold 2) 1

1 0 Credit 1 1 Credit Enhanced IAQ Strategies (threshold 1) 1 2 Credit 2 1 Credit Water Use Reduction (threshold 6) 1

1 Credit Regional Priority: Specific Credit 1

5 1 7 Materials and Resources 13 Y Prereq Required 54 7 67 TOTALS Possible Points: 110 Y Prereq Required 1 Credit 1

4 Credit 4

1 1 Credit 2

1 1 Credit 2 1 1 Credit Building Product Disclosure and Optimization - Material Ingredients 2 1 1 Credit 2

Bicycle Facilities

Construction and Demolition Waste Management Planning

Indoor Water Use Reduction Indoor Water Use Reduction

Fundamental Commissioning and Verification

Green Power and Carbon Offsets

Project Name:

Location and Transportation

Access to Quality Transit

LEED for Neighborhood Development Location

Integrative Process

Surrounding Density and Diverse Uses

Construction and Demolition Waste Management

Enhanced Indoor Air Quality Strategies Low-Emitting Materials

Minimum Indoor Air Quality Performance Environmental Tobacco Smoke Control

Interiors Life-Cycle Impact Reduction Long-Term Commitment

Enhanced Refrigerant Management

Enhanced Commissioning

Advanced Energy Metering

Building Product Disclosure and Optimization - Environmental Product Declarations Building Product Disclosure and Optimization - Sourcing of Raw Materials

Reduced Parking Footprint

Minimum Energy Performance Fundamental Refrigerant Management

Optimize Energy Performance

Thermal Comfort Interior Lighting Daylight Quality Views

Construction Indoor Air Quality Management Plan Indoor Air Quality Assessment

Certified: 40 to 49 points, Silver: 50 to 59 points, Gold: 60 to 79 points, Platinum: 80+

Innovation-Legal Wood, Lead, Biophilic Design LEED Accredited Professional

Storage and Collection of Recyclables

Acoustic Performance

Renewable Energy Production

ASI Global Partitions 900 Clary Connector Eastanollee, GA 30538 Tel: 706.827.2700 Fax: 706.827.2710 Web: asi-globalpartitions.com

STAINLESS STEEL

Finishes Selection Guide

STANDARD FINISH OPTIONAL FINISHES

SATIN LEATHER DIAMOND

Type 304 Stainless Steel

Corrosion Resistant

Recycled Content:

72% Post Consumer 18% Post Industrial

Actual colors may vary slightly from those shown due to limitations in the printing process.

All finishes are Type #304 Stainless Steel

Global Par ons

STAINLESS STEEL METAL SPECIFICATIONS

FLOOR AND CEILING ANCHORED

MAX CEILING HT 9’ 0”

MIN CEILING HT 7’ 6”

Date Issued 05-19

900 Clary Connector, Eastanollee, GA 30538 Tel: (706) 827-2700/ Fax (706) 827-2710 www.asi-globalpar ti ons.com

Global Par ons

STAINLESS STEEL METAL SPECIFICATIONS

900 Clary Connector, Eastanollee, GA 30538 Tel: (706) 827-2700/ Fax (706) 827-2710 www.asi-globalpar ti ons.com

NOTE

Structural steel should be 2 1/2" MAX from the bottom of the Finished Ceiling.

Schönox HA Because there’s nothing funny about waterproofing.

Take your business to a whole new level. Call 855.391.2649 or visit hpsubfloors.com to learn how your projects run smoother with Schönox Ön It.

READY MIXED, ROLLABLE WATERPROOF SEALING MEMBRANE &

CRACK ISOLATION

Schönox knows that dealing with water issues can soak an installer. If one step fails, it can ruin the entire project, costing both time and money. Use Schönox HA for installations of waterproof sealings under ceramic tiles in residential and commercial wet areas. Ready mixed, rapid drying, easy to apply and proven to work.

Schönox HA ready mixed, rollable waterproof sealing membrane & crack Isolation Suitable for waterproofing under ceramic tiles in residential and commercial interior wet areas. Schönox HA acts as a crack-isolation membrane without waterproofing requirements, applied in one coat at required thickness.

PRODUCT CHARACTERISTICS

• Interior use only

• Very low emissions

• One or two coat system

• Ready mixed

• Rapid drying

• Highly elastic

• Resistant against aging

• Easy to apply

• Ideal for trowel or roller application

• Solvent free

• Crack isolation over nonstructural cracks up to 1/16”

RECOMMENDED APPLICATION DETAILS

Schönox HA is suitable for sealing of:

• Concrete, cement substrates

• Masonry (fully grouted)

• Gypsum based substrates (compressive strength >2500 psi)

• Old substrates such as ceramic tiles

• Cement plaster, lime-cement plaster

• Gypsum plaster

• Wall panels of lightweight concrete

• Gypsum board

• Plywood, OSB boards

PRIMING

• Very porous and all gypsum based substrates: prime with SCHÖNOX KH FIX, drying time at least 1 hour

TECHNICAL DATA

• Basis: synthetic resin dispersion

• Color: blue-grey

• Application temperature: not below

+ 5°C / 41°F

• Ready for covering:

- after approx. 3 - 5 hours (depending on condiditions and thickness)

• Coverage: (at minimum thickness)

- approx. 200 sq.ft. per unit of 22 kg/3.8 gal.

- approx. 70 sq.ft. per unit of 7 kg/1.2 gal.

PACKAGING

• 22 kg / 3.8 gal. in a plastic container

• 7 kg / 1.2 gal. in a plastic container

LEED V4

May help contribute to LEED v4 certification of projects in these categories:

• EQc2 – 3 points

Low-Emitting Materials

• MRc2 – 1 point

Environmental Product Declaration

• MRc4 – 1 point

Material Ingredients

WATERTIGHTRAPID DRYING

Take your business to a whole new level. Call 855.391.2649 or visit hpsubfloors.com to learn how your projects run smoother with Schönox Ön It.

TROWELABLEMEETS ANSI STANDARDS

Product characteristics EMICODE EC 1PLUS: very low emission one or two coat system for interior use only ready mixed rapid drying watertight and permeable to water vapor highly elastic resistant against aging easy to apply ideal for trowel or roller application change of color after drying solvent-free can be flood tested after 16 hours drying time crack isolation over nonstructural cracks up to 1/16” / 2mm fulfills ASTM C627 (Robinson) for ‘extra heavy’ meets or exceeds ANSI A118.12 and ANSI A118.10

Applications SCHÖNOX HA is suitable to install a waterproof membrane in normal and heavy loaded wet areas such as showers and bathrooms SCHÖNOX HA fulfills relevant American ANSI standards as well as the European ETAG 022, part 1, for bonded sealing liquid to work with for walls and floors in wet rooms combined with the SCHÖNOX ST- SEALING COMPONENTS. ETAG approval number ETA-09/0247. SCHÖNOX HA is authorized by the German building supervision for installations of bonded sealings in heavy loaded wet areas in moisture loading classes A according to the building regulation A, Part 2, Figure

2.50. and fulfils the requirements of the test principles to issue a building authority approval for liquid treated membranes combined with ceramic tiles.

Substrates SCHÖNOX HA is suitable for sealing of:

concrete, cement substrates masonry (fully grouted) gypsum based substrates (compressive strength > 2,500 psi) old substrates such as ceramic tiles cement plaster, lime-cement plaster gypsum plaster wall panels of leight weight concrete gypsum board plywood, OSB boards

Requirements of substrate Subfloors must be smooth, sound, clean, Technical data Basis: synthetic resin dispersion Color: blue-grey Application temperature:

not below + 5 °C / 41°F Ready for covering:

after approx. 3 - 5 hours (depending on conditions and thickness)

Coverage (at minimum thickness):

approx. 200 sq.ft. per unit of 22kg / 3.8 gal.

approx. 70 sq.ft. per unit of 7kg / 1.2 gal

All values are approximate at 65 °F floor temperature, are subject to local climatic fluctuations and vary according to the absorbency of the substrate and to the applicator device. Do not install any topping before previous application has dried thoroughly.

dry and free of any contaminants which may hinder adhesion.

Surface treatments or any “friable” areas of the subfloor must be mechanically removed back to a sound base and the substrate repaired with SCHÖNOX repair compounds as required.

Concrete should be grinded to achieve CSP 2 prior to use of SCHÖNOX HA.

Old adhesives should be removed completely. Do not use any chemicals to prepare approved substrates.

With subsequent laying of ceramic coverings, cement substrates should be at least 28 days and have a maximum moisture content of 3 lbs./1000 sq. ft/24 hrs. (per ASTM F1869) or 75% RH (per ASTM F2170).

Gypsum substrates must always be dry!

Do not use over substrates containing asbestos, dimensionally unstable substrates and where hydrostatic pressure conditions exist.

Old floors such as ceramic tiles should be thoroughly cleaned and abraded.

The requirements of the relevant valid standards, guidelines and data sheets apply.

Priming Very porous and all gypsum based substrates:

prime with SCHÖNOX KH FIX, drying time at least 1 hour

Recommended method of working SCHÖNOX HA is ready for use and can be applied without further stirring using a suitable tool such as a metal trowel (1/4“x3/16“ or 3/16“x5/32“ V-notch trowel) or a 3/8” nap roller.

Do not add any water.

SCHÖNOX HA is applied in a one coat application at a minimum thickness of 20 mils or 1/32” (0.5mm dry film thickness).

The SCHÖNOX ST SEALING TAPE and the SCHÖNOX ST-COMPONENTS are installed beforehand into SCHÖNOX HA using a suitable roller.

Expansion joints as well as floor and wall connection joints are bridged, drains and pipe are sealed using the SCHÖNOX ST Accessories as required. Overlap at least 2“.

Minimum Layer thickness: To ensure a waterproof installation the minimum layer thickness after drying must be 20 mils or 1/32” following the recommended coverage rate.

Ceramic tiles can be installed directly over

SCHÖNOX HA

Ready Mixed, Rollable Waterproofing and Crack-Isolation Membrane

For installations under ceramic tiles or stone in residential and commercial areas.

Product data sheet

ETAG 022

approved according to

B u s

-0

H

A

SCHÖNOX HA after drying using a suitable ceramic tile adhesive (depending on the ceramic tiles to be installed).

The finished application must cover the substrate completely without any voids and pinholes. Inspect and recoat areas not covered completely and let dry accordingly.

Clean tools immediately after use.

If flood testing (per ASTM D5957) is required, allow SCHÖNOX HA to dry 16 hours depending on conditions (temperature, humidity, porosity of substrate).

To install SCHÖNOX HA as a crack-isolation membrane without waterproofing requirements, the membrane is applied in a one coat application at the required thickness. Apply a thickness of 1/16” (1mm dry film thickness) to isolate cracks up to 2mm, apply a coat of 1/32” (0.5mm dry film thickness) to isolate cracks up to 1mm. After complete drying of approx.

16 hours, SCHÖNOX APF or SCHÖNOX AP may be installed over the crack-isolation membrane without the need for priming (thickness of underlayment above 1/8”).

After drying of the underlayment following the referring technical data sheet install resilient floor coverings or wood floor as required.

Packaging 22 kg / 3.8 gal. in a plastic container 7 kg / 1.2 gal. in a plastic container

Storage Store in cool, dry, frost-free conditions Shelf life: 1 year unopened

Disposal Empty containers and dispose of in accordance with federal, state and local waste disposal regulations.

VOC Content 0g/l (calculated) SCAQMD 1168

LEED

May contribute to LEED v4 in categories:

EQc2 - 3 points

Low-Emitting Materials MRc2 - 1 point

Environmental Product Declaration MRc4 - 1 point

Material Ingredients

Environmental Product Declaration (EPD) Declaration number:

EPD-DIV-20140063-IBG1-EN

Instructions Always install an adequate number of properly located test areas to include the finish flooring, to determine the suitability of the product for its intended use. As ceramic tile coverings vary, always contact and rely upon the manufacturer for specific directions such as maximum allowable moisture content, adhesive selection, and intended end use of the product.

Low substrate temperatures and/or high ambient humidity require longer drying times.

Precautions Avoid eye and skin contact. Close container after each use. Do not reuse container.

Do not flush down drains, sewers or waterways.

In North America provided by:

HPS North America, Inc

Phone: 256.246.0345

Fax: 256.246.0346

Email: info@hpsubfloors.com http://www.hpsubfloors.com

Management system certified to ISO 9001 and 14001 by SQS.

SCHÖNOX HA

Product data sheet

Prior to each use of any SCHÖNOX product, the user must always read and follow the warnings and instructions on the product’s most current product label, Product Data Sheet and Safety

Data Sheet which are available at www.

schonox.us, or by calling the HPS SCHÖNOX

Technical Service Department at 855-391-2649.

Nothing contained in any SCHÖNOX materials relieves the user of the obligation to read and follow the warnings and instruction for each

SCHÖNOX product as set forth in the current product label, Product Data Sheet and Safety

Data Sheet prior to product use. This product data sheet supersedes all previous editions.

KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR

INDUSTRIAL USE ONLY • FOR PROFESSIONAL USE ONLY

SCHÖNOX products are supplied in the USA by SCHÖNOX HPS North America, a business unit of HPS North America, Inc. (HPS SCHÖNOX).

For further information and advice regarding transportation, handling, storage and disposal of chemical products, users should refer to the actual Safety Data Sheets containing physical, ecological, toxicological and other safety related data. Read the current actual Safety Data Sheet before using the product. In case of emergency, call GBK/Infotrac ID 108313 at 1 800 535 5053 (USA) or 001 352 323 3500 (International). HPS SCHÖNOX warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer’s sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESSED OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

HPS SCHÖNOX SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. HPS SCHÖNOX SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. Sale of SCHÖNOX products are subject to the Terms and Conditions of Sale which are available at www.schonox.us.

Safety Data Sheet

SCHÖNOX® HA

Revision Date 02/16/2018

Print Date 02/16/2018

1 / 10

1. Identification

Product name : SCHÖNOX® HA

Supplier : HPS North America, Inc., 511 Wilhite Street, Florence, AL 35630

USA

Telephone : 256.246.0345

Telefax : 256.246.0346

E-mail address : info@hpssubfloors.com

Emergency telephone : GBK/Infotrac ID 108313 at 1 800 535 5053 (USA)

INTERNATIONAL: (001) 352 323 3500

Recommended use of the chemical and restrictions on use

: For further information, refer to product data sheet.

2. Hazards identification

GHS Classification

Carcinogenicity, Category 1A (Inhalation) H350i: May cause cancer by inhalation.

Specific target organ systemic toxicity -repeated exposure, Category 1, Lungs

H372: Causes damage to organs through prolonged or repeated exposure.

Specific target organ systemic toxicity -repeated exposure, Category 2, Lungs (Inhalation)

H373: May cause damage to organs through prolonged or repeated exposure if inhaled.

GHS label elements

Hazard pictograms :

Signal Word : Danger

Hazard Statements : H350i May cause cancer by inhalation.

H372 Causes damage to organs (Lungs) through prolonged or repeated exposure.

H373 May cause damage to organs (Lungs) through prolonged or repeated exposure if inhaled.

Precautionary Statements : P101 If medical advice is needed, have product container or label at hand.

P102 Keep out of reach of children.

P103 Read label before use.

Prevention:

P201 Obtain special instructions before use.

P202 Do not handle until all safety precautions have been read

2 / 10 and understood.

P260 Do not breathe dust/ fume/ gas/ mist/ vapors/ spray.

P264 Wash skin thoroughly after handling.

P270 Do not eat, drink or smoke when using this product.

P281 Use personal protective equipment as required.

Response:

P308 + P313 IF exposed or concerned: Get medical advice/ attention.

Storage:

P405 Store locked up.

Disposal:

P501 Dispose of contents/ container to an approved waste disposal plant.

See Section 11 for more detailed information on health effects and symptoms.

There are no hazards not otherwise classified that have been identified during the classification process.

There are no ingredients with unknown acute toxicity used in a mixture at a concentration >= 1%.

3. Composition/information on ingredients

Pure substance/mixture : Mixture

Hazardous ingredients

Chemical name CAS-No. Concentration (%) barium sulfate 7727-43-7 >= 25 - < 50 % Quartz (SiO2) 14808-60-7 >= 2 - < 5 %

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

4. First aid measures

If inhaled : Move to fresh air.

Consult a physician after significant exposure.

In case of skin contact : Take off contaminated clothing and shoes immediately.

Wash off with soap and plenty of water.

If symptoms persist, call a physician.

In case of eye contact : Remove contact lenses.

Keep eye wide open while rinsing.

If eye irritation persists, consult a specialist.

If swallowed : Clean mouth with water and drink afterwards plenty of water.

Do not induce vomiting without medical advice.

Do not give milk or alcoholic beverages.

Never give anything by mouth to an unconscious person.

Most important symptoms : See Section 11 for more detailed information on health effects

3 / 10 and effects, both acute and delayed and symptoms.

carcinogenic effects

May cause cancer by inhalation.

Causes damage to organs through prolonged or repeated exposure.

Protection of first-aiders : Move out of dangerous area.

Consult a physician.

Show this material safety data sheet to the doctor in attendance.

Notes to physician : Treat symptomatically.

5. Fire-fighting measures

Suitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Specific extinguishing methods

: Collect contaminated fire extinguishing water separately. This must not be discharged into drains.

Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Special protective equipment for fire-fighters

: In the event of fire, wear self-contained breathing apparatus.

6. Accidental release measures

Personal precautions, protective equipment and emergency procedures

: Use personal protective equipment.

Deny access to unprotected persons.

Environmental precautions : Do not flush into surface water or sanitary sewer system.

If the product contaminates rivers and lakes or drains inform respective authorities.

Local authorities should be advised if significant spillages cannot be contained.

Methods and materials for containment and cleaning up

: Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Keep in suitable, closed containers for disposal.

7. Handling and storage

Advice on safe handling : Avoid exceeding the given occupational exposure limits (see section 8).

Do not get in eyes, on skin, or on clothing.

For personal protection see section 8.

Smoking, eating and drinking should be prohibited in the application area.

Follow standard hygiene measures when handling chemical

4 / 10 products.

Conditions for safe storage : Prevent unauthorized access.

Store in original container.

Keep container tightly closed in a dry and well-ventilated place.

Observe label precautions.

Store in accordance with local regulations.

Materials to avoid : No data available

8. Exposure controls/personal protection

Component CAS-No. Basis ** Value Exposure limit(s)* / Form of exposure barium sulfate 7727-43-7 OSHA P0

TWA

10 mg/m3 Total

OSHA P0

5 mg/m3 Respirable fraction

OSHA Z-1

15 mg/m3 total dust respirable fraction

ACGIH

Inhalable fraction

10 mg/m3 Total dust respirable dust fraction

Quartz (SiO2) 14808-60-7 OSHA Z-3

10 mg/m3 / %SiO2+2 respirable

OSHA Z-3

250 mppcf / %SiO2+5 respirable

0.1 mg/m3

ACGIH

0.025 mg/m3

0.05 mg/m3 Respirable dust

5 / 10

*The above mentioned values are in accordance with the legislation in effect at the date of the release of this safety data sheet.

**Basis ACGIH. Threshold Limit Values (TLV) OSHA P0. Table Z-1, Limit for Air Contaminat (1989 Vacated Values) OSHA P1. Permissible Exposure Limits (PEL), Table Z-1, Limit for Air Contaminant OSHA P2. Permissible Exposure Limits (PEL), Table Z-2 OSHA Z3. Table Z-3, Mineral Dust

Engineering measures : Use of adequate ventilation should be sufficient to control worker exposure to airborne contaminants. If the use of this product generates dust, fumes, gas, vapor or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure below any recommended or statutory limits.

Personal protective equipment

Respiratory protection : Use a properly fitted NIOSH approved air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary.

The filter class for the respirator must be suitable for the maximum expected contaminant concentration (gas/vapor/aerosol/particulates) that may arise when handling the product. If this concentration is exceeded, self-contained breathing apparatus must be used.

Hand protection Remarks : Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.

Eye protection : Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary.

Skin and body protection : Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place.

Hygiene measures : Avoid contact with skin, eyes and clothing.

Wash hands before breaks and immediately after handling the product.

Remove contaminated clothing and protective equipment before entering eating areas.

9. Physical and chemical properties

6 / 10

Appearance : paste

Color : blue gray

Odor : characteristic

Odor Threshold : No data available

Flash point : > 214 °F (101 °C)

Ignition temperature : No data available

Decomposition temperature : No data available

Lower explosion limit (Vol%) : No data available

Upper explosion limit (Vol%) : No data available

Flammability (solid, gas) : No data available

Oxidizing properties : No data available pH : 8

Melting point/range / Freezing point

: No data available

Boiling point/boiling range : No data available

Vapor pressure : 17 mmHg (23 hpa)

Density : 1.55 g/cm3 at 68 °F (20 °C)

Water solubility : No data available

Partition coefficient: n-octanol/water

: No data available

Viscosity, dynamic : No data available

Viscosity, kinematic : > 20.5 mm2/s at 104 °F (40 °C)

Relative vapor density : No data available

Evaporation rate : No data available

Burning rate : No data available

Volatile organic compounds (VOC) content

: 0.0 g/l (calculated)

10. Stability and reactivity

Reactivity : No dangerous reaction known under conditions of normal use.

7 / 10

Chemical stability : The product is chemically stable.

Possibility of hazardous reactions

: Stable under recommended storage conditions.

Conditions to avoid : No data available

Incompatible materials : No data available

11. Toxicological information

Acute toxicity

Not classified based on available information.

Skin corrosion/irritation

Not classified based on available information.

Serious eye damage/eye irritation

Not classified based on available information.

Respiratory or skin sensitization

Skin sensitization: Not classified based on available information.

Respiratory sensitization: Not classified based on available information.

Germ cell mutagenicity

Not classified based on available information.

Reproductive toxicity

Not classified based on available information.

STOT-single exposure

Not classified based on available information.

STOT-repeated exposure

Causes damage to organs (Lungs) through prolonged or repeated exposure.

May cause damage to organs (Lungs) through prolonged or repeated exposure if inhaled.

Aspiration toxicity

Not classified based on available information.

Carcinogenicity

May cause cancer by inhalation.

IARC

Group 1: Carcinogenic to humans

Quartz (SiO2) 14808-60-7

Group 2B: Possibly carcinogenic to humans titanium dioxide 13463-67-7

NTP

Known to be human carcinogen

Quartz (SiO2) 14808-60-7 Titanium dioxide (13463-67-7)

In lifetime inhalation studies of rats, airborne respirable-size titanium dioxide particles have seen shown to cause an increase in lung tumors at concentrations associated with substantial particle lung burdens and consequential pulmonary overload and inflammation. The potential for these adverse health effects appears to be closely related to the particle size and the amount of the

8 / 10 exposed surface area that comes into contact with the lung. However, tests with other laboratory aninals such as mice and hamsters, indicate that rats are significantly more susceptible to the pulmonary overload and inflammation that cause lung cancer. Epidemiology studies do no suggest an increased risk of cancer in humans from occupational exposure to titanium dioxide.

Titanium dioxide has been characterized by IARC as possibly carcinogenic to humans (Group 2B) through inhalation (not ingestion). It has not been characterized as a potential carcinogen by either NTP or OSHA.

12. Ecological information

Other information Do not empty into drains; dispose of this material and its container in a safe way.

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

13. Disposal considerations

Disposal methods

Waste from residues : Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Contaminated packaging : Empty containers should be taken to an approved waste handling site for recycling or disposal.

14. Transport information

DOT

Not dangerous goods

IATA

Not dangerous goods

IMDG

Not dangerous goods

Special precautions for user No data available

Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Not applicable

15. Regulatory information

TSCA list : All chemical substances in this product are either listed on the

9 / 10

TSCA Inventory or are in compliance with a TSCA Inventory exemption.

EPCRA - Emergency Planning and Community Right-to-Know

CERCLA Reportable Quantity

Ingredients CAS-No. Component RQ (lbs) sodium hydroxide 1310-73-2 1000

SARA304 Reportable Quantity

This material does not contain any components with a section 304 EHS RQ.

SARA 311/312 Hazards : Carcinogenicity

Specific target organ toxicity (single or repeated exposure)

SARA 302 : This material does not contain any components with a section

302 EHS TPQ.

SARA 313 : This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.

Clean Air Act

Ozone-Depletion Potential

This product neither contains, nor was manufactured with a Class I or Class II ODS as defined by the U.S. Clean Air Act Section 602 (40 CFR 82, Subpt. A, App.A + B).

This product does not contain any hazardous air pollutants (HAP), as defined by the U.S. Clean Air Act Section 112 (40 CFR 61).

This product does not contain any chemicals listed under the U.S. Clean Air Act Section 112(r) for Accidental Release Prevention (40 CFR 68.130, Subpart F).

California Prop 65 WARNING: Cancer – www.P65Warnings.ca.gov

16. Other information

HMIS Classification

Caution: HMIS® rating is based on a 0-4 rating scale, with 0 representing minimal hazards or risks, and 4 representing significant hazards or risks. Although HMIS® rating is not required on SDSs under 29 CFR 1910.1200, the preparer may choose to provide them. HMIS® rating is to be used with a fully implemented HMIS® program. HMIS® is a registered mark of the National Paint & Coatings Association (NPCA). Please note HMIS® attempts to convey full health warning information to all employees.

Physical Hazard

Flammability

Personal Protection

Health 3*

X

10 / 10

Notes to Reader

The information contained in this Safety Data Sheet applies only to the actual Product name identified and described herein ("Product Name").

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .