472_23198_JGH_Ionia_VMS Upgrade_BID Drawings COMBINED.pdf

PDF 16 MB Posted

Attached to
472/23198. JGH; Ionia CF - VMS Upgrade
Solicitation number
RFQ 171 260000000314 3
Issued by
Huron County, Michigan

About this file

This document comprises bid drawings and technical specifications for the State of Michigan's Video Management System (VMS) Upgrade project at Ionia Correctional Facility located at 1576 Bluewater Highway, Ionia, Michigan 48846. The project, designated file number 472/23198.JGH, involves comprehensive security infrastructure upgrades including installation of new security cameras, network equipment, access control systems, and electrical power infrastructure throughout multiple facility buildings. The scope encompasses new camera installations across administrative buildings, support services, education facilities, warehouse buildings, and six housing units, along with perimeter security enhancements including new camera poles with 360-degree coverage and fiber optic backbone connectivity. The drawings include detailed floor plans, electrical schematics, equipment schedules, and installation specifications prepared by Commtech Design (security systems) and Matrix Consulting Engineers (electrical work). The project requires coordination of work across multiple building systems including fire-rated wall penetrations, conduit installation, UPS power systems, and telecommunications infrastructure.

The electrical specifications detail extensive requirements for conduit routing, wire sizing, equipment grounding, surge protection devices, and compliance with the 2023 Michigan Electrical Code and MDOC standards. All work must be completed with minimal electrical outages not exceeding two hours, requiring portable generator support for perimeter detection and video management systems during switchovers. Equipment specifications include Vertiv 1500VA UPS units (model GXT5), Hanwha cameras in multiple configurations (fixed, PTZ, and 360-degree fisheye models), Genetec Streamvault archiving systems, Cisco network switches with fiber optic connectivity, and Altronix access control equipment. The document emphasizes strict security requirements including tamper-proof fasteners below ten feet, restricted conduit materials (no PVC inside buildings), and MDOC-approved equipment only. Pre-bid site visits are mandatory for contractors to assess existing conditions, and all work must adhere to facility security protocols with coordination required two weeks in advance for any electrical outages or system cutover activities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWING LIST:

TC101 IONIA SECURITY LEGENDS, DETAILS, AND SCHEDULES

TC102 IONIA CONNECTIVITY CODES DETAILS

TC103 IONIA CABLING & SECURITY MOUNTING DETAILS

TC104 IONIA CABLING & SECURITY MOUNTING DETAILS

TC105 IONIA POLE MOUNTING & NEW PC DETAILS

TC106 IONIA DUAL WARDENS CONFERENCE DETAILS

TC107 IONIA FIBER BACKBONE

TC108 IONIA RACK LAYOUTS

TC109 IONIA RACK LAYOUTS

TC110 IONIA SECURITY CAMERA ONE LINE DIAGRAMS

TC111 IONIA SECURITY CAMERA ONE LINE DIAGRAMS

TC112 IONIA SECURITY CAMERA ONE LINE DIAGRAMS

TC113 IONIA SECURITY CAMERA ONE LINE DIAGRAMS

TC114 IONIA SECURITY CAMERA ONE LINE DIAGRAMS

TC115 IONIA SECURITY CAMERA ONE LINE DIAGRAMS

TC116 IONIA SECURITY CAMERA ONE LINE DIAGRAMS

TC117 IONIA SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER

TC118 IONIA SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER

TC119 IONIA ACCESS CONTROL CABLE LABELING

TC120 IONIA ACCESS CONTROL SYSTEM (PACS)

TC121 IONIA DOOR HARDWARE & SECURITY REQUIREMENTS

TC122 IONIA SYMPHONY SCHEDULE, DETAILS & REQUIREMENTS

TC301 IONIA ADMINISTRATION BLDG. 100 - ALL FLOORS - NEW AND ADDITIONAL

TC302A IONIA SUPPORT SERVICES - FIRST FLOOR - A - NEW AND ADDITIONAL

TC302B IONIA SUPPORT SERVICES - FIRST FLOOR & MEZZANINE - B - NEW AND ADDITIONAL

TC303 IONIA SUPPORT SERVICES - SECOND FLOOR - NEW AND ADDITIONAL

TC304 IONIA EDUCATION - FIRST FLOOR - NEW AND ADDITIONAL

TC305 IONIA EDUCATION - SECOND FLOOR - NEW AND ADDITIONAL

TC306 IONIA MSI - FIRST FLOOR - & MEZZANINE NEW AND ADDITIONAL

TC307 IONIA HOUSING UNIT 1 - LOWER LEVEL - NEW AND ADDITIONAL

TC308 IONIA HOUSING UNIT 1 - UPPER LEVEL - NEW AND ADDITIONAL

TC309 IONIA HOUSING UNIT 2 - LOWER LEVEL - NEW AND ADDITIONAL

TC310 IONIA HOUSING UNIT 2 - UPPER LEVEL - NEW AND ADDITIONAL

TC311 IONIA HOUSING UNIT 3 - LOWER LEVEL - NEW AND ADDITIONAL

TC312 IONIA HOUSING UNIT 3 - UPPER LEVEL - NEW AND ADDITIONAL

TC313 IONIA HOUSING UNIT 4 - LOWER LEVEL - NEW AND ADDITIONAL

TC314 IONIA HOUSING UNIT 4 - UPPER LEVEL - NEW AND ADDITIONAL

TC315 IONIA HOUSING UNIT 5 - LOWER LEVEL - NEW AND ADDITIONAL

TC316 IONIA HOUSING UNIT 5 - UPPER LEVEL - NEW AND ADDITIONAL

TC317 IONIA HOUSING UNIT 6 & 7- NEW AND ADDITIONAL

TC318 IONIA SITE PLAN - NEW AND ADDITIONAL

STATE OF MICHIGAN

IONIA CORRECTIONAL FACILITY

VIDEO MANAGEMENT SYSTEM UPGRADE

IONIA CORRECTIONAL FACILITY

1576 Bluewater Highway, Ionia, MI 48846

FILE NUMBER: 472/23198.JGH

SECURITY DESIGN

COMMTECH DESIGN

6585 BELDING RD. NE, SUITE B

ROCKFORD, MI 49341

(616) 863-8132

SECURITY DRAWING INDEX

ELECTRICAL ENGINEER

MATRIX CONSULTING ENGINEERS, INC.

544 CHERBOURG DRIVE

LANSING, MI 48917

(517) 487-2511

ELECTRICAL DRAWING INDEX

DRAWING LIST:

E-100 IONIA ELECTRICAL SYMBOLS, ABBREV. & NOTES

E-200 IONIA - SITE PLAN - POWER

E-500 IONIA - EAST - 100 ADMIN. BLDG. FIRST FLOOR - POWER

E-501 IONIA - EAST - 100 ADMIN. BLDG. SECOND FLOOR - POWER

E-502 IONIA - 200 SUPPORT SERVICES. - FIRST FLOOR - AREA B - POWER

E-503 IONIA - 200 SUPPORT SERVICES. - SECOND FLOOR - POWER

E-504 IONIA - 300 EDUCATION BLDG. - FIRST FLOOR - POWER

E-505 IONIA - 300 EDUCATION BLDG. - SECOND FLOOR - POWER

E-506 IONIA - 400 WAREHOUSE BLDG. - FIRST FLOOR - POWER

E-507 IONIA - HOUSING UNIT 1 - BASEMENT - POWER

E-508 IONIA - HOUSING UNIT 2 - BASEMENT - POWER

E-509 IONIA - HOUSING UNIT 3 - BASEMENT - POWER

E-510 IONIA - HOUSING UNIT 4 - BASEMENT - POWER

E-511 IONIA - HOUSING UNIT 5 - BASEMENT - POWER

E-512 IONIA - HOUSING UNIT 6/7 - FIRST FLOOR - POWER

E-800 ELECTRICAL DETAILS

E-801 ELECTRICAL DETAILS

COVER

C om m te ch

D es ig n

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

AutoCAD SHX Text

SHEET NUMBER

AutoCAD SHX Text

472/23198.JGH

AutoCAD SHX Text file no.

AutoCAD SHX Text checked by

AutoCAD SHX Text drawn by

AutoCAD SHX Text consultant

AutoCAD SHX Text issue date

AutoCAD SHX Text acctg template.

AutoCAD SHX Text contract order no.

AutoCAD SHX Text 472ICFMaintproj

AutoCAD SHX Text consultant job no.

AutoCAD SHX Text 1065_24B

AutoCAD SHX Text sheet title

AutoCAD SHX Text

VIDEO SECURITY FLOOR PLANS

AutoCAD SHX Text

VIDEO MANAGEMENT SYSTEM UPGRADE

AutoCAD SHX Text

IONIA CORRECTIONAL FACILITY

AutoCAD SHX Text

IONIA, MICHIGAN

AutoCAD SHX Text Y23464

AutoCAD SHX Text

VIDEO SECURITY UPGRADES

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text U

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text M

AutoCAD SHX Text S

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text P

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text

CONSULTING ENGINEERS, INC

AutoCAD SHX Text

FAX: 517.487.2544

AutoCAD SHX Text

PHONE: 517.487.2511

AutoCAD SHX Text

LANSING, MI 48906

AutoCAD SHX Text

1601 E CESAR E. CHAVEZ AVE.

AutoCAD SHX Text

MATRIX PROJECT:

AutoCAD SHX Text WEB: www.matrixceinc.com

AutoCAD SHX Text

CONSULTING ENGINEERS, INC

AutoCAD SHX Text

FAX: 517.487.2544

AutoCAD SHX Text

PHONE: 517.487.2511

AutoCAD SHX Text

LANSING, MI 48906

AutoCAD SHX Text

1601 E CESAR E. CHAVEZ AVE.

AutoCAD SHX Text

MATRIX PROJECT:

AutoCAD SHX Text WEB: www.matrixceinc.com

AutoCAD SHX Text 5/14/26

AutoCAD SHX Text

ISSUE FOR BID

AutoCAD SHX Text 5/14/26

AutoCAD SHX Text

ISSUE FOR BID

TVSS

VFD

TRANSIENT VOLTAGE SURGE SUPPRESSION

VARIABLE FREQUENCY DRIVEDUPLEX RECEPTACLE

DOCK LIGHT FIXTURE

TELEPHONE / DATA OUTLET

ELECTRICAL SYMBOLS LEGEND

J

SINGLE RECEPTACLE (120 VOLT)

EMERGENCY RECEPTACLE

DOUBLE DUPLEX RECEPTACLE

FLUSH FLOOR BOX

SURFACE FLOOR BOX

SPECIAL EQUIPMENT RECEPTACLE

TELEPHONE OUTLET

DATA OUTLET

POWER POLE

JUNCTION BOX

WALL JUNCTION BOX

PULL (JUNCTION) BOX

UNDERFLOOR JUNCTION BOX

OUTLETS

LIGHT FIXTURE

STRIP FIXTURE

IN-GRADE LIGHT FIXTURE

SPOTLIGHT (number of heads shown) EXIT SIGN (face & direction as shown)

WALL MOUNT LIGHT FIXTURE

CEILING LIGHT FIXTURE

TRACK & FIXTURE

STREET TYPE POLE FIXTURE

POLE MOUNTED LIGHT FIXTURE

EXTERIOR WALL MOUNT LIGHT FIXTURE

WALLPACK LIGHT FIXTURE

SPECIAL PURPOSE LIGHT FIXTURE

HIGH BAY LIGHT FIXTURE

EMERGENCY EGRESS LIGHT FIXTURE

(number of heads shown)

EMERGENCY LIGHT FIXTURE

FIXTURES

CIRCUITRY and RACEWAYS

UNDERFLOOR DUCT

BUS DUCT

PLUGMOLD AS SPECIFIED

WIREMOLD AS SPECIFIED

FLEXIBLE PIGTAILS/CONNECTIONS

"CONDUIT RUN CONTINUES" INDICATION

END OF CONDUIT RUN, CAP AND STAKE

END OF CONDUIT RUN

HOME RUN (with circuit numbers)

CONDUIT STUB DOWN

CONDUIT STUB UP

CONDUIT INSTALLED

CONDUIT INSTALLED

SOUND and SIGNAL

SERVICE and EQUIPMENT

THERMOSTAT

CAPACITOR

ENCLOSED CIRCUIT BREAKER

TRANSFER SWITCH

WIREWAY

GROUND CONNECTION PER N.E.C.

TELEPHONE TERMINAL BOARD

GENERATOR, KW SHOWN

CURRENT TRANSFORMERS

UTILITY METER, AS REQUIRED

WEATHERHEAD

PANELBOARD, FLUSH MOUNTED

PANELBOARD, SURFACE MOUNTED

COMB. STARTER

MAGNETIC STARTER

DISCONNECT SWITCH

TRANSFORMER

CONTROL

xxVA connection by x/C) IRRIGATION CONTROLLER (120 volt

LIGHTING CONTACTOR

CONTROL TRANSFORMER

buttons indicated) PUSHBUTTON STATION (number of TIME CLOCK (24 hour U.O.N.)

PHOTOCELL (voltage as required)

HUMIDISTAT

(by E.C.)

(by others)

TT

G

WW

PC

CT

TS

T

H

TC

IC

T

1,3

OR

PM

WM

BD

UFD

F S

J

J

PP

J

CEILING MOUNTED WIFI

DIGITAL EQUIPMENT METER, AS REQUIRED

POLE

PUMP

PANEL

P

PNL

PVC

PRV-

P-

PB

POLY VINYL CLORIDE

POWER ROOF VENTILATOR

PULL BOX

GENERAL CONTRACTOR

GROUND

HUMIDIFIERH-

GND

GFI

GC

GROUND FAULT INTERUPTER

ABBREVIATIONS LEGEND

POWER

SWITCH

RECEPT

SF-

SWBD

TCC

SPEC

SW

RGC

RTU-

PWR

VOLTS

WATTS

UF

V

W

UL

VL

UNO

UH-

TS

TYP

TR

ROOF TOP UNIT

RECEPTACLE

SWITCHBOARD

UNDER FLOOR

SPECIFICATIONS

RIGID GALVANIZED STEEL CONDUIT

UNLESS NOTED OTHERWISE

UNDERWRITERS' LABORATORIES, INC.

TAMPER PROOF RECEPTACLE

TAMPER PROOF SWITCH

TEMPERATURE CONTROL CONTRACTOR

VERIFY LOCATION WITH OWNER

TYPICAL

UNIT HEATER

SUPPLY FAN

WITH

WITHOUT

W/

XFMR

W/O

WP

TRANSFORMER

WEATHER PROOF

HOUR

LIGHT

JUNCTION BOX

LIGHT CONTROL

ISOLATED GROUND

HORSEPOWER

MINIMUM

MOUNT

MAKE-UP AIR UNIT

MOTOR CONTROL CENTER

MAIN LUG ONLY

MOUNTED

MOUNTING

MAXIMUM

LIGHTING

LT FLEX

MTD

MUAU-

MTG

MLO

MIN

MT

MC

MAX

MCC

LTG

IG

LC

LT

IMC

JB

HR

HVAC

HOA

HP

NORMALLY CLOSED

NOT IN CONTRACT

NORMALLY OPEN

NOT TO SCALE

NIGHT LIGHTNL

NTS

NO

NIC

NC

HAND-OFF-AUTO SELECTOR SWITCH

HEATING/VENTILATING/AIR CONDITIONING

INTERMEDIATE METAL CONDUIT

LIQUID TIGHT FLEXIBLE METAL CONDUIT

MECHANICAL CONTRACTOR

HID HIGH INTENSITY DISCHARGE

A

AC

AFF

ACU-

AHJ

AHU-

AS

B-

BC

AIC

ATS

BLDG

CHLR-

CND (C)

CKT BKR

CKT

CUH-

CU-

DISC

DFU-

EF-

EC

DWH-

EBB-

DWG

CT-

EXIST (E)

EWC

FLEX

FLA

FLR

FSES

FLUOR

EMT

ABOVE FINISHED FLOOR

AIR CONDITIONING UNIT

AMPS

ABOVE COUNTER

AIR HANDLING UNIT

AUTOMATIC TRANSFER SWITCH

AMPS INTERUPTING CAPACITY

AUTHORITY HAVING JURISDICTION

ABOVE SHELF

BOILER

BUILDING

BELOW COUNTER

CHILLER

DOMESTIC WATER HEATER

CABINET UNIT HEATER

CIRCUIT

CIRCUIT BREAKER

CONDUIT

CONDENSING UNIT

COOLING TOWER

DUCT FURNACE

DRAWING

DISCONNECT

FOOD SERVICE EQUIP. SUPPLIER

ELECTRIC WATER COOLER

ELECTRICAL CONTRACTOR

ELECTRIC BASEBOARD

ELECTRICAL METALLIC TUBING

EXISTING

EXHAUST FAN

FLOOR

FLUORESCENT

FLEXIBLE CONDUIT

FULL LOAD AMPS

EM EMERGENCY

F/S FIRE/SMOKE

FU- FURNACE

SSCP

COCCTV

SECURITY SYSTEM CONTROL PANEL

CAMERA

DATA RACK

RACK MOUNTED UPS

BRACKET MOUNTED UPS

NEW 1500VA UPS- EQUIPMENT SPECIFICATION

1500VA UNINTERRUPTIBLE POWER SUPPLY (UPS) - VERTIV GXT5

PROVIDE UNINTERRUPTIBLE POWER SUPPLY (UPS). UPS SHALL BE

1.5KVA RATED, HIGH EFFICIENCY, DOUBLE CONVERSION, CONTINUOUS

DUTY, ON-LINE TYPE. INPUT VOLTAGE OF 120VAC, 60HZ, 1-PHASE, 3-WIRE

PLUS GROUND. OUTPUT VOLTAGE OF 120VAC, 60HZ, 1-PHASE, 4-WIRE

PLUS GROUND. INCLUDE ALARM RELAY BOARD FOR REMOTE

MONITORING, LITHIUM ION BATTERIES, 13 MINUTE RUN TIME, SELF

DIAGNOSTICS. NEMA 5-15 PLUG WITH (6) NEMA 5-15R RECEPTACLES.

INCLUDE A VERTIV WALL MOUNT BRACKET, PART NUMBER WMBKT2U,

WHERE SHOWN IN DRAWINGS.

INCLUDE 5 YEAR ON-SITE WARRANTY SERVICE FOR PARTS AND LABOR.

SEQUENCE OF EQUIPMENT INSTALL:

1. INSTALL NEW WALL MOUNT BRACKET IF APPLICABLE.

2. INSTALL NEW 1500VA BRACKET OR RACK MOUNTED UPS AS SHOWN

IN DRAWINGS.

3. RELOCATE CAMERA EQUIPMENT POWER TO NEW UPS.

4. REMOVE OLD UPS.

POLE

POLE

HOW HIGH ON WALL

DR

RUPS

BUPS

P

C

X

X

X ADDENDUM NOTE

PLAN NOTE

DEMOLITION NOTE

SWITCHES

SINGLE-POLE SWITCH

DIMMER SWITCH

TIME SWITCH

KEY SWITCH

MANUAL MOTOR SWITCH

THERMAL OVERLOAD SWITCH

SWITCH WITH PILOT LIGHT

FOUR-WAY SWITCH

THREE-WAY SWITCH

DESIGNATIONS

D

PLUG STRIP (PDU)

DESCRIPTION AND COMMENTSTYPE MANUFACTURER CATALOG NO.

NEW CAMERA POLE SCHEDULE

DS210-590A200-D1PC-FPDB-FBC-AB - POLE

LDV05-1C-06ARM-HMLED4LUM-P3-KPHASE-70-AG-LAJB - TRUSS

18' TAPERED STEEL POLE WITH BASE, 2" X 4" HAND HOLE AT 18" FROM

THE BASE TO HAND HOLE, ANCHOR BOLTS PER MANUFACTURE

RECOMMENDATIONS, TRUSS TO SUPPORT (1) 360 DEGREE TYPE

CAMERA CENTERED OVER SALLY PORT DRIVE. BRONZE FINISH.

VALMONT

OR PSC APPROVED

EQUAL

DATA RACK

(4) #10 AWG

(1) #10 GND

(1) 3/4" CND

VERTIV PART NUMBER I10087, OR

PRE-APPROVED EQUAL, MOUNTED ON

DATA RACK OR CABLE LADDER. REFER TO

FLOOR PLANS FOR DEVICE COLOR .

ARCHIVER PDU DETAIL

SCALE: N.T.S.1

(4) #10 AWG

(1) #10 GND

(1) 3/4" CND

REFER TO

FLOOR PLANS

FOR (2)

CIRCUITS

VERTIV PART NUMBER I10087, OR

PRE-APPROVED EQUAL, MOUNTED ON

DATA RACK OR CABLE LADDER. REFER TO

FLOOR PLANS FOR DEVICE COLOR .

DIRECTORY

DIRECTORY

CONNECT ARCHIVERS AND DIRECTORIES

TO RACK MOUNTED PDU'S. REFER TO

COMMTECH DRAWINGS FOR RACK

LAYOUT.

ADMIN PDU DETAIL

SCALE: N.T.S.2

DATA RACK

(2) #12 AWG

(1) #12 GND

(1) 3/4" CND

VERTIV PART NUMBER 38607, OR

PRE-APPROVED EQUAL, MOUNTED ON

DATA RACK OR CABLE LADDER. DEVICE

COLOR IN ADMINISTRATION BUILDING

SHALL BE BLUE, ALL OTHER DEVICES

SHALL BE RED.

REFER TO

FLOOR

PLANS

(2) #12 AWG

(1) #12 GND

(1) 3/4" CND

REFER TO

FLOOR

PLANS

ARCHIVER

ARCHIVER

ARCHIVER

ARCHIVER

ARCHIVER

ARCHIVER

ARCHIVER

BLUE 30A L21-30R TWISTLOCK

RECEPTACLE

BLUE 30A L21-30R TWISTLOCK

RECEPTACLE

20A L5-20R TWISTLOCK

RECEPTACLE

20A L5-20R TWISTLOCK

RECEPTACLE

RACK MOUNTED RECEPTACLE AND UPS DETAIL

SCALE: N.T.S.3

DATA RACK

(2) #12 AWG

(1) #12 GND

(1) 3/4" CND

REFER TO

FLOOR

PLANS

20A RED QUAD RECEPTACLE

FROM GENERATOR POWER.

MOUNT ON RACK.

1500VA UPS

GENERAL ELECTRICAL NOTES

ALL WORK SHALL BE IN COMPLIANCE WITH THE 2023 MICHIGAN

ELECTRICAL CODE AND MDOC STANDARDS.

1. ALL NON-FIRE RATED WALLS ARE TO BE PATCHED WITH LIKE

MATERIAL TO MAINTAIN ORIGINAL RATING.

2. ALL WALL AND FLOOR PENETRATIONS THROUGH FIRE RATED WALLS

ARE TO BE SEALED WITH FIRE CAULK TO MAINTAIN ORIGINAL

RATING. EXISTING PENETRATIONS IN THE AREA OF WORK THAT ARE

NOT PROPERLY SEALED ARE TO BE SEALED TO MATCH THE RATING

OF THE WALL.

3. ALL CONDUITS SHALL BE FIELD ROUTED ALONG EXISTING PIPING

AND STRUCTURAL STEEL. CONDUITS SHALL BE INSTALLED

STRAIGHT, LEVEL, AND PARALLEL OR PERPENDICULAR TO THE

BUILDING LINES.

4. CONTRACTORS SHALL VISIT THE PROJECT SITE DURING PRE-BID

WALK THROUGH TO DETERMINE THE EXACT EXTENT OF THE WORK

REQUIRED BEFORE BIDDING THE PROJECT.

5. REMOVE ALL EXISTING OBSOLETE EXPOSED CONDUIT, WIRE, AND

EQUIPMENT NOT TO BE RE-USED WHERE WORK IS BEING DONE

EXCEPT ITEMS NOTED OTHERWISE.

6. WHERE BUILDING SURFACES ARE DAMAGED BY THE REMOVAL OF

OLD WORK, SURFACES SHALL BE PATCHED AND PAINTED TO MATCH

ADJACENT.

7. EXISTING WORK, WHICH IS PRESENTLY CONCEALED, WHICH WILL

REMAIN CONCEALED, AND DOES NOT INTERFERE WITH ANY NEW

WORK OF ANY TRADE NEED NOT BE REMOVED. HOWEVER, ALL

CONDUIT SHALL BE CAPPED BELOW FINISH SURFACE AND THEN

PATCHED AND PAINTED TO MATCH, OR AS NOTED.

8. EXISTING OPENINGS, WHICH ARE TO BE REUSED, SHALL BE

MODIFIED OR ENLARGED TO SUIT THE NEW SYSTEMS AS REQUIRED.

PROVIDE ALL REQUIRED CUTTING AND PATCHING.

9. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING THE EXISTING

WALLS TO MATCH THE ADJACENT SURFACES BEHIND ALL SURFACE

MOUNTED EQUIPMENT.

10. CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT AND LOADS

PRIOR TO INSTALLING SERVICE TO EQUIPMENT.

11. DRAWINGS ARE BASED ON EXISTING RECORD DOCUMENTS AND

CASUAL FIELD OBSERVATION. REPORT ANY DISCREPANCIES TO

ENGINEER FOR CLARIFICATION.

12. CONDUITS AND BOXES:

12.1. 3/4" MINIMUM TRADE SIZE.

12.2. EMT TYPE CONDUIT IS APPROVED WITH COMPRESSION

FITTINGS.

12.3. NO PVC ALLOWED INSIDE OF BUILDINGS.

12.4. CONDUITS SHALL BE ATTACHED WITH TWO-HOLE STRAPS.

SINGLE HOLE STRAPS ARE NOT PERMITTED.

12.5. NO SET SCREWS ARE ALLOWED.

12.6. TAMPER-PROOF SCREWS REQUIRED FOR EXPOSED CONDUIT

AND BOXES MOUNTED BELOW TEN FEET.

12.7. DRIVE PIN ANCHORS USED ON MASONARY OR CONCRETE

WALLS/CEILINGS.

13. MINIMUM RACEWAY SIZE; 3/4" TRADE SIZE. ALL FLEXIBLE CONDUIT

RACEWAYS SHALL BE LIQUID TITE, MAXIMUM 72" LENGTH AND MUST

BE APPROVED BY PSC AND MDOC PROJECT MANAGER. REFER TO

SPECIFICATION 260533 - RACEWAY AND BOXES FOR ELECTRICAL

SYSTEMS.

14. INSTALLATION OF ANY NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW CURRENT NEC AND MDOC STANDARDS.

15. CONDUIT, CONDUIT INSTALLATION, AND BOXES BEING REUSED

SHALL BE BROUGHT UP TO CURRENT MDOC STANDARDS.

16. ALL CONDUIT AND BOXES ABOVE 10 FOOT OR IN

MECHANICAL/ELECTRICAL ROOMS, SHALL MEET THE FOLLOWING

REQUIREMENTS:

16.1. STRAP DISTANCE: 5 FEET.

16.2. FASTENERS: 2 HOLE.

16.3. CONDUIT” INTERIOR EMT, EXTERIOR EXPOSED/CONCEALED-

GRC.

16.4. FITTINGS: COMPRESSION.

16.5. BOXES: STANDARD BOXES FOR ENVIORNMENT INSTALLED TO

MEET N.E.C.

16.6. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND

ENCLOSURES.

17. ALL CONDUIT AND BOXES 10 FOOT AND BELOW SHALL MEET THE

FOLLOWING REQUIREMENTS:

17.1. STRAP DISTANCE: 3 FEET.

17.2. FASTENERS: 2 HOLE WITH SECURITY SCREWS.

17.3. SECURITY HARDWARE:

17.3.1. TORX T-25 WITH CENTER REJECTION PIN.

17.3.2. HEX HEAD CONCRETE SCREWS WITH NO SCREWDRIVER

SLOT.

17.3.3. EXPANSION POUND-IN ANCHORSWITH NO SCREWDRIVER

SLOT THAT DO NOT REQUIRE TO BE EXPLOSIVELY DRIVEN.

17.3.4. PRE-APPROVED HARDWARE.

17.4. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED -

GRC.

17.5. FITTINGS: COMPRESSION

17.6. BOXES:

17.6.1. SURFACE MOUNTED:

17.6.1.1. BELL BOX: FS TYPE, WITH SQUARE HEAD KO SEAL.

17.6.1.2. NO KNOCKOUTS - DRILL AS REQUIRED.

17.7. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND

ENCLOSURES.

18. ALL EXPOSED WIRING SHALL BE IN CONDUIT. OPEN LOW VOLTAGE

WIRING ABOVE ACCESIBLE CEILINGS IS ACCEPTABLE.

18.1. ALL EXPOSED WIRING ABOVE CEILINGS SHALL BE INSTALLED

WITH J-HOOKS. DO NOT CONNECT TO EXISTING CEILING TIE

WIRES.

19. ALL WALLS THAT ARE ACCESSIBLE SHALL BE FISHED AND DEVICE

CUT INTO WALL.

20. ALL LOCATIONS WHERE THE WALLS CAN NOT BE FISHED SHALL BE

SURFACE MOUNTED CONDUIT FOLLOWING NOTES 14 THROUGH 15

ABOVE.

21. ALL EXTERIOR CONCEALED CONDUIT UNDERGROUND SHALL BE

RNC/HDPE SCHEDULE 80. ALL EXTERIOR ABOVE GROUND CONDUIT

SHALL BE RGC UP TO 10 FEET ABOVE GRADE. PROVIDE UL LISTED

#12 COPPER TRACER WIRE TO ALL UNDERGROUND CONDUITS

INSTALLED FOR LOW VOLTAGE.

22. ALL ELECTRICAL OUTAGES SHALL NOT LAST OVER 2-HOURS. IF A

WINDOW OF GREATER THAN 2 HOURS FOR AN ELECTRICAL SHUT

DOWN OR CUT OVER IS REQUIRED, THEN A PORTABLE GENERATOR

SHALL BE USED TO REPLACE POWER TO ALL PERIMETER DETCTION,

VIDEO MANAGEMENT, LINE SAFTEY, AND ANY OTHER ELECTRICAL

SERVICE REQUIRED. ALL OUTAGES AND CUT OVERS SHALL BE

COORDINATED A MINIMUM OF 2-WEEKS PRIOR TO WORK, INCLUDING

AN HOUR BY HOUR SCHEDULE, MUST BE SUBMITTED TO MDOC

LEADERSHIP AND THE FACILITY FOR REVIEW.

23. WHEN RELOCATING ANY ELECTRICAL DEVICE, CONTRACTOR SHALL

COMPLETE THE RELOCATION IN ONE DAY AND VERIFY THAT ALL

DEVICES RELOCATED ARE WORKING PROPERLY PRIOR TO LEAVING

THE SITE.

24. CONTRACTOR SHALL PROVIDE AND INSTALL ALL REQUIRED

COMPONENTS, RACEWAYS, WIRE, AND HARDWARE, AS INDICATED

ON DRAWINGS.

25. CONTRACTOR SHALL PROVIDE UPDATED PANEL SCHEDULES FOR

ALL PANELS AFFECTED BY THIS PROJECT. UPDATED SCHEDULES

SHALL BE PRINTED AND INSTALLED ON THE INSIDE COVER OF THE

PANEL.

26. ALL WORK COMPLETED WITHOUT APPROVED SHOP DRAWINGS IS AT

CONTRACTOR'S RISK.

27. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF

ALL 24V CONTROL WIRING AS REQUIRED TO LOCALLY CONTROL ALL

HVAC & PLUMBING IN ACCORDANCE WITH THE SEQUENCE OF

OPERATIONS. REFER TO THE MECHANICAL DRAWINGS FOR ALL

LOCAL THERMOSTAT LOCATIONS AND MECHANICAL SPECIFICATIONS

FOR INSTALLATION REQUIREMENTS. COORDINATE IN FIELD WITH

MECHANICAL CONTRACTOR AS REQUIRED. ELECTRICAL

CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUIT, WIRE,

AND HARDWARE AS REQUIRED IN ACCORDANCE WITH ELECTRICAL

SPECIFICATIONS. REFER TO SHEET E-100 DETAIL 1 FOR ADDITIONAL

INFORMATION.

28. CONTRACTOR SHALL NOTIFY PSC OF ANY EXISTING INSTALLATIONS

NOT MEETING THESE STANDARDS PRIOR TO STARTING WORK IN THE

AREA.

29. UPON RELOCATING LIGHTS AND CAMERAS CONTRACTORS SHALL

VERIFY THAT THE LIGHTS AND CAMERAS ARE WORKING PROPERLY

PRIOR TO LEAVING THE SITE.

30. CONTRACTOR SHALL USE MDOC APPROVED POLES AND FIXTURES,

NO ALTERNATES WILL BE ALLOWED. ALL OTHER STATE OF MICHIGAN

AGENCY SPECIFICATIONS DO NOT APPLY.

31. CONTRACTOR SHALL NOT ADD MORE THAN 20% CAPACITY TO ANY

PANEL.

32. ARC FLASH LABELS TO BE PROVIDED FOR ALL NEW PANELBOARDS.

33. NEW PRINTED CIRCUIT DIRECTORIES SHALL BE PROVIDED FOR ALL

NEW AND REVISED PANELBOARDS.

34. CONTRACTOR SHALL SUBMIT AN RFI FOR ANY NON-CODE

COMPLIANT ELECTRICAL EQUIPMENT OR ELECTRICAL INSTALLATION.

AN RFI RESPONSE WILL BE PROVIDED GIVING DIRECTION ON HOW

TO PROCEED.

E-100

DRK

JFS

WEST SITE PLAN

POWER

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

5/14/26 ISSUE FOR BID

C

C

C C

C

C

C

C

C

C

C

C C

C

C

C

C

C C

C C

C

C

C

C

PL-017

PL-018

PL-019

PL-020

PL-021

PL-022

PL-023

PL-024

PL-025

PL-026

PL-027

PL-028

PL-029

PL-030

PL-031

PL-032

PL-033

PL-034

PL-035

PL-036

PL-037

PL-038PL-039

PL-039B

PL-001

PL-002

PL-003

PL-004

PL-005

PL-006

PL-007

PL-008

PL-009

PL-010

PL-011

PL-012

PL-013

PL-014 PL-015

PL-016

PL-001B

PL-039A

PL-016A

PL-008A

PL-027A

PL-033A

PL-001A

C

C

C

C

C

C C

C

C

C C

C

C

C C C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

CC

CC

C

C

C

C

C

C

C

C

C

C

C

C C

C P

2 2

(1) 1" CND

(1) 1" CND

(1) 1" CND

C2

C2

C

C 2

C 2

C

C

C

C

5 6

C

C 2

C 2C

C C

(1) 1" CND

ELECTRICAL KEY NOTES

PROVIDE AND INSTALL NEW SURGE PROTECTION DEVICES

AND JUNCTION BOX FOR CAMERAS ON POLE. ALL POLES ARE

EXISTING TO REMAIN UNLESS OTHERWISE SPECIFIED. REFER

TO SHEET E-800 DETAIL 3.

PROVIDE AND INSTALL NEW SURGE PROTECTION DEVICE IN

COMMUNICATIONS ROOM FOR CAMERAS ON BUILDING.

REFER TO SHEET E-800 DETAIL 2.

REMOVE EXISTING SURGE PROTECTION DEVICES AND

HORNER LIGHTING CONTROLS. PROVIDE AND INSTALL NEW

SURGE PROTECTION DEVICES IN PERIMETER CABINET

(RAYCAP G29-00-394-OTL-PROTEC-T1-40 AND RAYCAP

NJ2010B). REFER TO SHEET E-800 DETAIL 1. REMOVE ALL

HARDWARE AND EXPOSED WIRING FROM THE CABINET AND

MAKE SAFE.

PROVIDE AND INSTALL NEW POLE AND BASE FOR NEW 360

DEGREE SALLY PORT DRIVE CAMERA. REFER TO SHEET E-801

DETAILS 3&4 AND POLE SCHEDULE ON SHEET E-100.

PROVIDE AND INSTALL NEW NEMA 3R RATED JUNCTION BOX

ON THE EXTERIOR WALL OF BUILDING. LOCATE THE

JUNCTION BOX OUTSIDE THE COMMUNICATIONS ROOM.

DIRECTIONALLY BORE CONDUIT TO JUNCTION BOX ON

EXTERIOR WALL OF BUILDING AS SHOWN. REFER TO LOW

VOLTAGE DRAWINGS FOR CABLE TYPE AND QUANTITY.

PROVIDE AND INSTALL NEW NEMA 3R RATED JUNCTION BOX

ABOVE CAGE FOR NEW CAMERAS. REFER TO LOW VOLTAGE

DRAWINGS FOR DETAILS.

EXISTING LIGHT FIXTURES

EXISTING STEEL POLE

GRADE GRADE

EXISTING HANDHOLE

FROM NEXT POLE/CABINET

36"

GROUND WIRE

SPLICE CABLE

JUNCTION BOX

TO CABINET

EXIST. CONDUIT

AND WIRE FOR

LIGHT FIXTURE

POWER

SCALE: N.T.S.

TYPICAL EXISTING LIGHT POLE DETAIL DEMOLITION

EXISTING LIGHT

FIXTURE WIRE

EXISTING LIGHT

FIXTURE CONTROL

WIRE

EXISTING LIGHT FIXTURE POLE AND FIXTURE HEADS TO REMAIN. EXISTING

LIGHT FIXTURE WIRE TO REMAIN. DISCONNECT AND REMOVE EXISTING

LIGHT FIXTURE CONTROL CONDUIT AND WIRE BACK TO SOURCE.

DISCONNECT AND REMOVE LIGHTING CONTROL RELAY LOCATED AT BASE

OF POLE. EXISTING JUNCTION BOX TO REMAIN.

DEMOLITION NOTES

E-200

JJD

JFS

SITE PLAN

POWER

N ELECTRICAL - SITE PLAN - POWER

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

5/14/26 ISSUE FOR BID

SCALE: 1" = 60'-0"

400 10 20 80 150

SUPPORT SERVICES

EX

EX

EXEX

EX

EX

EX

EX

EX

EX

1 1

UPS-A-24

UPS-A-26 UPS-A-28

UPS-A-30

UPS-A-38

UPS-A-36

UPS-A-36

J

UPS-A-32

UPS-A-34

ELECTRICAL KEY NOTES

PROVIDE AND INSTALL NEW 20A BLUE QUAD RECEPTACLE

FROM PANEL "UPSA".

PROVIDE AND INSTALL CONDUIT AND WIRE FOR NEW

CONFERENCE TABLE RACEWAY. REFER TO LOW VOLTAGE

DRAWINGS FOR MORE DETAILS.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-500

JFS

EAST 100 ADMIN - FIRST

FLOOR

N

ELECTRICAL - EAST 100 ADMIN FLOOR PLAN - FIRST

FLOOR - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

5/14/26 ISSUE FOR BID

JJD

CAPTAIN'S OFFICE

INSPECTOR

OFFICE

HEARING'S

INVESTIGATOR

INSPECTOR

OFFICE

ASSISTANT

DEPUTY WARDEN

OFFICE

DEPUTY

WARDEN

DR

DR

EX PANEL "UPS-A"

120/208V-3Ø, 100A DR

EX 30KVA UPS

TEX 30KVA XFMR

TL

TL

TL

TL

TL

TL

EX PANEL "MPB"

480V-3Ø, 600A

EX PANEL "UPS"

480V-3Ø, 30A

TEX

EX PANEL "L-RPX"

120/208V-3Ø, 100A

EX PANEL "RPX"

120/208V-3Ø, 100A

EX PANEL "LP-XA"

277V-3Ø, 100A

REPLACED PANEL "RP-A"

120/208V-3Ø, 100A

EX PANEL "LP-ZA"

277V-3Ø, 100A

EX PANEL "LP-BB"

277V-3Ø, 100A

EX PANEL "EMPB"

480V-3Ø, 100A

UPS-A-19,21,23

UPS-A-25,27,29

UPS-A-31

UPS-A-33

RP-A-43

UPS-A-35

RP-A-45

RP-A-47

DR

TL

TL

ELECTRICAL KEY NOTES

PROVIDE AND INSTALL (2) NEW BLUE 30A L21-30R TWISTLOCK

RECEPTACLE FROM UPS POWER. CONNECT TO SEPARATE

VERTICAL POWER STRIPS ON BACK OF RACK. PROVIDE AND

INSTALL ALL CONDUIT WIRE AND HARDWARE AS REQUIRED.

REFER TO SHEET E-100 DETAIL 1.

PROVIDE AND INSTALL (1) NEW BLUE 20A TWISTLOCK

RECEPTACLE FROM UPS POWER AND (1) NEW RED 20A

TWISTLOCK RECEPTACLE FROM GENERATOR POWER.

CONNECT TO SEPARATE VERTICAL POWER STRIPS ON BACK

OF RACK. PROVIDE AND INSTALL ALL CONDUIT WIRE AND

HARDWARE AS REQUIRED. REFER TO SHEET E-100 DETAIL 2.

PROVIDE AND INSTALL (2) VERTIV I10087 POWER STRIPS ON

THE BACK OF THE RACK. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL (2) VERTIV 38607 POWER STRIPS ON

THE BACK OF THE RACK. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL NEW LINE VOLTAGE SURGE

PROTECTION DEVICE IN PANEL (RAYCAP

RSE-2-277-3Y-A-10-E-F-S).

PROVIDE AND INSTALL NEW LINE VOLTAGE SURGE

PROTECTION DEVICE IN PANEL (RAYCAP

RSE-2-277-3Y-A-5-E-F-S).

DISCONNECT AND REMOVE EXISTING HORNER LIGHTING

CONTROL SERVER. REMOVE ASSOCIATED CONDUIT AND

WIRE. PROVIDE AND INSTALL NEW LIGHTING CONTROL

OVERRIDE SWITCH IN THIS AREA. CONNECT TO EXISTING

ULTRALINK SYSTEM. CONTRACTOR SHALL VERIFY FINAL

LOCATION WITH OWNER PRIOR TO INSTALLATION.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-501

JFS

EAST 100 ADMIN - SECOND

FLOOR

N

ELECTRICAL - EAST 100 ADMIN FLOOR PLAN - SECOND

FLOOR - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

JJD

AREA B

AREA B

AREA A

AREA A

BU

PS

RP-E-35

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL

NEW 1500VA BRACKET MOUNTED UPS FOR CAMERA PC AND MONITOR.

PROVIDE AND INSTALL ALL CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. CONNECT TO 1500VA

UPS UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

RU

PS

E-502

JFS

200 SUPPORT SERVICES -

AREA B - FIRST FLOOR

N

ELECTRICAL - 200 SUPPORT SERVICES FLOOR PLAN -

FIRST FLOOR - AREA B - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

5/14/26 ISSUE FOR BID

KEY PLAN

JJD

N

ELECTRICAL - 200 SUPPORT SERVICES FLOOR PLAN -

MEZZANINE - AREA B - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

RUPS

PANEL RP-E

120/208V-3Ø, 100A

RP-E-37

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-503

JFS

200 SUPPORT SERVICES -

SECOND FLOOR

N

ELECTRICAL - 200 SUPPORT SERVICES FLOOR PLAN -

SECOND FLOOR - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

BUPS

EX PNL EMPB

480/277V-3Ø, 200A

EX PNL MPB

480/277V-3Ø, 600A

EX PNL LP-XX

480/277V-3Ø, 60A

EX PNL RPX

120/208V-3Ø, 100A

TEX

TEX

EX PNL RPD

120/208V-3Ø, 100A

EX PNL RPF

120/208V-3Ø, 100A

1 RPD-25

EX PNL LP-ZZ

480/277V-3Ø

RU

PS2

RPD-29

ELECTRICAL KEY NOTES

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE AND 1500VA BRACKET

MOUNTED UPS FOR NEW SECURITY EQUIPMENT. MOUNT ABOVE DOOR.

PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND BREAKERS AS

REQUIRED.

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-504

JFS

300 EDUCATION BLDG -

FIRST FLOOR

N

ELECTRICAL - 300 EDUCATION BLDG FLOOR PLAN -

FIRST FLOOR - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

RU

PS

RPD-27

RPD-27

BUPS

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE AND 1500VA BRACKET

MOUNTED UPS FOR NEW SECURITY EQUIPMENT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, HARDWARE, AND BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-505

JFS

300 EDUCATION BLDG -

SECOND FLOOR

N

ELECTRICAL - 300 EDUCATION BLDG FLOOR PLAN -

SECOND FLOOR - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

RUPS1

EXISTING 30KVA UPS

EX PANEL "LPA"

277/480V-3Ø, 225A

EX PANEL "UPS"

277/480V-3Ø, 60A

EX SUB PANEL

120/208V-3Ø, 100A

EX PANEL "E"

120/208V-3Ø, 30A

EX PANEL "YA"

277/480V-3Ø, 225A

EX PANEL "LPEE"

277/480V-3Ø, 225A

EX SW "M-MDP"

277/480V-3Ø

E-13

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-506

JFS

400 WAREHOUSE BLDG -

FIRST FLOOR

N

ELECTRICAL - 400 WAREHOUSE BLDG FLOOR PLAN -

FIRST FLOOR - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

5/14/26 ISSUE FOR BID

JJD

ELECTRICAL - MSI BLDG 400 - FLOOR PLAN

400 MSI BLDG.

277/480V-30, 60A

"UPS"

277/480V-30, 60A

"UPS"

120/208V-30, 100A

"UPS"

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

RUPS

EX SW "EM"

480/277V-3Ø, 225A

EX PANEL "H2"

120/208V-3Ø, 100A

EX PANEL "H"

120/208V-3Ø, 100A

EX PANEL "LPH"

480/277V-3Ø, 100A

EX SW "H-MDP"

480/277V-3Ø, 225A

EX PANEL "EH"

120/208V-3Ø, 50A

EH-34

E-507

JFS

HOUSING UNIT 1

BASEMENT

N

ELECTRICAL - HOUSING UNIT 1 FLOOR PLAN -

BASEMENT - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

A-X

MECH.BOILERROOM

A-1

CENTERSTAIR

EX SW "EM"

480/277V-3Ø, 225A

EX PANEL "H2"

120/208V-3Ø, 100A

EX PANEL "H"

120/208V-3Ø, 100A

EX PANEL "LPH"

480/277V-3Ø, 100A

EX SW "H-MDP"

480/277V-3Ø, 225A

EX PANEL "EH"

120/208V-3Ø, 50ARUPS

EH-34

E-508

JFS

HOUSING UNIT 2

BASEMENT

N

ELECTRICAL - HOUSING UNIT 2 FLOOR PLAN -

BASEMENT - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

EX SW "EM"

480/277V-3Ø, 225A

EX PANEL "H2"

120/208V-3Ø, 100A

EX PANEL "H"

120/208V-3Ø, 100A

EX PANEL "LPH"

480/277V-3Ø, 100A

EX SW "H-MDP"

480/277V-3Ø, 225A

EX PANEL "EH"

120/208V-3Ø, 50ARUPS

EH-36

E-509

JFS

HOUSING UNIT 3

BASEMENT

N

ELECTRICAL - HOUSING UNIT 3 FLOOR PLAN -

BASEMENT - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

EX SW "EM"

480/277V-3Ø, 225A

EX PANEL "H2"

120/208V-3Ø, 100A

EX PANEL "H"

120/208V-3Ø, 100A

EX PANEL "LPH"

480/277V-3Ø, 100A

EX SW "H-MDP"

480/277V-3Ø, 225A

EX PANEL "EH"

120/208V-3Ø, 50ARUPS

EH-32

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-510

JFS

HOUSING UNIT 4

BASEMENT

N

ELECTRICAL - HOUSING UNIT 4 FLOOR PLAN -

BASEMENT - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

EX SW "EM"

480/277V-3Ø, 225A

EX PANEL "H2"

120/208V-3Ø, 100A

EX PANEL "H"

120/208V-3Ø, 100A

EX PANEL "LPH"

480/277V-3Ø, 100A

EX SW "H-MDP"

480/277V-3Ø, 225A

EX PANEL "EH"

120/208V-3Ø, 50ARUPS

EH-35

E-511

JFS

HOUSING UNIT 5

BASEMENT

N

ELECTRICAL - HOUSING UNIT 5 FLOOR PLAN -

BASEMENT - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

JJDJJD

RUPS

EX PANEL "EG"

120/208V-3Ø, 100A

EX PANEL "EG-1"

120/208V-1Ø, 70A

EX PANEL "B"

120/208V-3Ø, 225A

EX PANEL "A"

120/208V-3Ø, 225A

EG-1-10

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL

NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-512

JFS

HOUSING UNIT 6/7

N ELECTRICAL - HOUSING UNIT 6/7 FLOOR PLAN - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

CAMERA JUNCTION BOX INSTALLATION DETAIL

SCALE: N.T.S.3

#10 AWG

#10 AWG

#10 AWG

#10 AWG

ETHERNET SWITCH

CABINET

LIGHTING ARRESTORS

ELECTRICAL EQUIPMENT

TYPICAL FOR

EACH PIECE OF

EQUIPMENT

CONNECT TO GROUND BAR

#10 AWG

TELECOMMUNICATIONS

GROUND BAR

GROUND BAR TYPICAL

TYPICAL CRIMP LUG CONNECTIVITY

1. ALL GROUNDING CONNECTIONS SHALL BE ROUTED TO CLOSEST

GROUND BAR.

2. GROUND BAR WILL BE PROVIDED WITH THE CABINET AND WILL BE

CONNECTED TO THE EARTH, ELECTRICAL GROUNDING SYSTEM,

AND POLE.

3. ALL BONDING CONNECTIONS SHALL BE MAKE WITH TWO HOLE

CRIMP LUGS ONLY AT THE GROUND BAR.

4. FROND CONNECTIONS SHALL BE MAKE WITH A MINIMUM OF #10

AWG CABLE.

5. ALL GROUND WIRES SHALL HAVE GREEN INSULATION.

GROUNDING NOTES

COMMUNICATIONS GROUNDING DETAIL

SCALE: N.T.S.6

WALL FIELD BUILD-OUT FOR CAMERAS ON POLES FED FROM BUILDINGS DETAIL

SCALE: N.T.S.4

BUILDING MOUNTED CAMERA SURGE PROTECTION DETAIL

SCALE: N.T.S.2

NETWORK CABINET DETAIL - TYPICAL FOR PERIMETER CABINETS

SCALE: N.T.S.1

CAMERA MOUNTED ON POLE DETAIL

SCALE: N.T.S.5

TYPICAL CONDUIT MOUNTING DETAIL

SCALE: N.T.S.

SQUARE POLE1" RGS CONDUIT

SQUARE POLE

STAINLESS

STEEL PIPE

STRAP.

3 REQUIRED,

MIN.

STAINLESS

STEEL

MOUNTING

BRACKET

ROUND STEEL

OR WOOD

POLE

1" RGS CONDUIT

ROUND POLE

STAINLESS

STEEL PIPE

STRAP.

3 REQUIRED,

MIN.

STAINLESS

STEEL

MOUNTING

BRACKET

POLE1" RGS CONDUIT

ANGLE POLE

STAINLESS

STEEL PIPE

STRAP.

3 REQUIRED,

MIN.

STAINLESS

STEEL

MOUNTING

BRACKET

71500VA WALL BRACKET DETAIL

SCALE: N.T.S.8

1500VA UPS UNIT

TOP BRACKET

BOTTOM BRACKET

SCREW SECURING BRACKET TO WALL

(TYPICAL) REPEAT ON BOTTOM BRACKET

SCREW SECURING BRACKET TO UPS UNIT

(TYPICAL) REPEAT ON BOTTOM BRACKET

PATCH PANEL

DATA SWITCH

EXTERIOR BUILDING WALL

RACK MOUNTED SURGE

PROTECTOR DITEK MODEL

NUMBER DTK-RM12NETS

TO GROUND BUS TYP.

#10 GROUND

WIRE

NEW 1" RIGID CONDUIT

TO CAMERA

EXISTING 1" CONDUIT TO

CABINET

NEW SURGE

SUPPRESSOR

RAYCAP NJ2010B

NEW 8"W X 8"H X 4"D

ENCLOSURE, NEMA 3R, HINGED

JUNCTION BOX HOFFMAN

A10R86HCR. IF 3 OR MORE

CAMERAS ON POLE, INCREASE

HEIGHT TO 16".

PROVIDE WITH PAD

LOCKABLE HASP

STAINLESS

STEEL PIPE

STRAP, TYP.

STEEL

CHANNEL,

UNISTRUT OR

EQ.

EXISTING #6 COPPER

GROUND WIRE IN 3/4" PVC

CONDUIT TO 3/4" X 8' GROUND

ROD AND POLE.

POLE

SIDE VIEWFRONT VIEW

NEW 1"x3"x1/4" TK.

COPPER GROUND BAR.

TSS

NEW CAT-6 CABLE TO

CAMERA AND GROUND.

GROUND CABLE TO

CAMERA GROUND LUG.

EXISTING

CAT-6 CABLE

EXISTING GROUND

WIRE IN POLE TO

EXISTING GROUND

ROD

NEW #10 GND

WIRE

EXISTING POWER

STRIP FED FROM

UPS

REMOVE EXISTING AND REPLACE WITH NEW

SURGE SUPPRESSORS, LIGHTING ARRESTORS

EXISTING MODULAR JACKS IN

SURFACE MOUNT BOX

EXISTING TYPICAL

COMMUNICATION CONDUITS TO

LIGHT POLES AND OTHER

CABINETS

EXISTING GROUND BAR

NEW CAT 6 CABLES TO

CAMERAS

NEW CAT 6 CABLES TO

CAMERAS

EXISTING 2'X2'

FIREPROOF PLYWOOD

WALL FIELD

NEW CAT 6 CABLES TO

CAMERAS

CAT-6 PATCH CABLES

ADD D-RINGS AS REQUIRED

EXISTING MODULAR JACKS IN

SURFACE MOUNT BOX

EXISTING MODULAR JACKS

IN SURFACE MOUNT BOX

EXISTING MODULAR JACKS

IN SURFACE MOUNT BOX

EXISTING CONDUIT FROM

UPS

NEW #10 WIRE, (1)

PER SURGE

PROTECTION DEVICE.

CAT-6 PATCH CABLES

EXISTING POE INJECTORS

EXISTING CAT 6 CABLES TO

CAMERAS.

NEW CAT 6 CABLES TO

CAMERAS.

EXISTING CAT 6 CABLES TO

CAMERAS.

NEW CAT 6 CABLES TO

CAMERAS.

NEW #10 GROUND WIRE TO

CAMERAS

EXISTING

GROUND

WIRE TO

GROUND ROD

GRADE

HANDHOLE

FIXED CAMERA

MOUNTING HEIGHT

EXISTING

1" TYPE C

JUNCTION BOX

EXISTING POLE

PTZ CAMERA

MOUNTING HEIGHT

NEW 3/4" RIGID CONDUIT

EXISTING BACK BOX

16' AFG MINIMUM

OR 2' ABOVE

RAZORWIRE

MINIMUM

22' AFG MINIMUM

OR 2' ABOVE

RAZORWIRE

MINIMUM

46-52" AFG

EXISTING GROUND WIRE

EXISTING GROUND ROD

NEW JUNCTION BOX.

REFER TO SHEET

E-801 DETAIL 3

EXISTING LOW VOLTAGE CONDUIT

TO CABINET

K

EXISTING MOUNTING POLE

EXISTING MODULAR JACKS IN

SURFACE MOUNT BOX. TERMINATE

ALL NEW CABLES HERE FOR

TESTING.

EXISTING MODULAR JACKS

IN SURFACE MOUNT BOX.

EXISTING

MOUNTING

POLE

NEW SURGE PROTECTION

DEVICES.

EXISTING POE INJECTORS

EXISTING POWER

SUPPLY FOR

ETHERNET

SWITCH- TO

REMAIN

EXISTING

ETHERNET

SWITCH

FUTURE

SWITCH

EXISTING POWER

SUPPLY FOR

ETHERNET

SWITCH- FUTURE

EXISTING FIBER OPTIC

PATCH PANEL

RESERVED FOR ELECTRICAL

EXISTING PLUG STRIP

TO POWER SOURCE

NEW #10 GROUND WIRE

EXISTING TYPICAL

COMMUNICATIONS

CONDUITS WITH

NEW #10 GND TO

LIGHT POLES AND

OTHER CABINETS.

EXISTING GROUND BAR

REFER TO SHEET E-800

DETAIL 6 FOR TERMINATION

INFORMATION. ADD

ADDITIONAL GROUND BARS

AS NEEDED FOR NEW #10

GND

NEW #10 GROUND

WIRE

EXISTING

GROUND

WIRE TO

GROUND ROD

LIGHTING

CONTROLLER

LIGHTING

CONTROLLER

POWER

DISCONNECT AND REMOVE LIGHTING CONTROLLER AND

LIGHTING CONTROLLER POWER DEVICES.

DISCONNECT AND REMOVE CAT6 CABLE FROM EXISTING

ETHERNET SWITCH TO EXISTING LIGHTING CONTROL

SERVER LOCATED IN ADMINISTRATION BUILDING.

DISCONNECT AND REMOVE CAT6 CABLE FROM ETHERNET

SWITCH TO LIGHTING CONTROLLER.

DISCONNECT AND REMOVE LIGHTING CONTROL CABLE AND

CAMERA CONTACT CLOSURE CABLE

DEMOLITION NOTES

1 1

EXISTING AUXILIARY

GUTTER

EXISTING

CONDUIT AND

WIRE TO POLES

FOR LIGHT

FIXTURE POWER

EXISTING

CONDUIT AND

WIRE TO POLES

FOR LIGHT

FIXTURE POWER

E-800

DRK

JFS

ELECTRICAL DETAILS

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

SALLY PORT CAMERA DRIVE DETAIL

SCALE: N.T.S.4

SALLY PORT

NEW CAMERA MOUNTED

CENTER OF GATE

NEW POLE TRUSS

NEW CAMERA POLE

SALLY PORT DRIVE

GRADE

NEW 1" LOW

VOLTAGE CONDUIT

FROM LOW VOLTAGE

HAND HOLE

3'

PROVIDE #4 REBAR CAGES

IN EACH FOUNDATION

6'-6"

PROVIDE 6'-6" DEEP 24" DIAM. CONCRETE

BASE POURED IN PLACE OR PRECAST

CONCRETE FOUNDATION

NEW EARTH

HAND HOLE

SALLY PORT OVERHEAD CAMERA DETAIL

SCALE: N.T.S.3

FACTORY INSTALLED

VIBRATION DAMPENER

NEW 360 DEGREE

CAMERA CENTERED

ON SALLY PORT DRIVE

NEW POLE

2-3/8" BOX

CONNECTOR

NEW CAMERA

BACK BOX

NEW JUNCTION BOX. NEW

SURGE PROTECTION DEVICE

LOCATED INSIDE.

18'

14'

NEW CAMERA POLE BASE

BUILDING 200

PERIMETER

FENCE

SECURED

AREA

UNSECURED

AREA

SCALE: N.T.S.

SURGE PROTECTION

DEVICE

#10 GROUND WIRE IN 1"

CONDUIT FROM POLE TO

CABINET.

FIXED OR PTZ

CAMERA ON POLE

GROUND AT CABINET

TYPICAL PERIMETER CAMERA CABINET TO POLE GROUNDING DIAGRAM

SCALE: N.T.S.7

LOW VOLTAGE

SURGE PROTECTION

DEVICE.

#10 GROUND

WIRE IN 3/4"

CONDUIT

TSS

#6 GROUND

WIRE IN 3/4" CND

SURGE

PROTECTION

DEVICE.

NEW 3/4" X 8'

GROUND ROD

#10 GROUND

WIRE

1"X3"X1/4'" COPPER

GROUND BAR

#12 GROUND WIRE

GROUND BAR

NEMA 3R,

JUNCTION BOX

#6 GROUND

WIRE IN 3/4" CND

EXISTING

3/4" X 8'

GROUND ROD

CAMERA BACK

BOX

#10 GROUND WIRE IN 1"

CONDUIT TO LIGHT POLES

AND OTHER CABINETS

#10 GROUND

WIRE

#10 GROUND

WIRE

#10 GROUND

WIRE

TYPICAL PERIMETER CAMERA CONNECTIVITY DIAGRAM - EXISTING POLE1

CAB-XXX

ETHERNET

SWITCH

POE

INJECTOR

SURGE

PROTECTOR

SURGE

PROTECTOR

EXISTING PERIMETER CABINET. REFER TO

SHEET E-800 DETAIL 1 FOR CABINET

CONNECTIVITY

CONNECT TO GROUND

BAR #10 AWG TYP.

CONDUIT WITH CAT-6 CABLE

AND NEW #10 GROUND

NEW JUNCTION BOX. NEW SURGE

PROTECTION DEVICE

RAYCAP NJ2010B LOCATED INSIDE.

REFER TO SHEET E-800 DETAIL 3

FIXED CAMERA

SEE SHEET E-00 DETAIL 5 FOR HEIGHTS

(1) 3/4" RIGID

CONDUIT

ADD ADDITIONAL

GROUND BARS AS

REQUIRED.

(1) 3/4" RIGID

CONDUIT

NEW CAT-6 PATCH

CABLE & NEW

GROUND CABLE IN

CONDUIT

NEW CAT-6 PATCH

CABLE & NEW

GROUND CABLE IN

CONDUIT

PTZ CAMERA

SEE SHEET E-00 DETAIL 5 FOR HEIGHTS

NEW JUNCTION BOX. NEW SURGE

PROTECTION DEVICE

RAYCAP NJ2010B LOCATED INSIDE.

REFER TO SHEET E-800 DETAIL 3

GROUND

BUS

EXISTING GROUND

WIRE TO ROD

#6 GROUND TO

NEW GROUND ROD

#6 GROUND TO

NEW GROUND ROD

E-801

DRK

JFS

ELECTRICAL DETAILS

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a tr ix

M a tr ix

5/14/26 ISSUE FOR BID

NEW CAMERA POLE BASE

UNSECURED AREA

CAMERA EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO. DROP CEILING HARD

CEILING/WALL

BUILDING

EXTERIOR

BUILDING

EXTERIOR

CORNER

POLE MOUNT

SECURITY EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

ABBREVIATIONS

ABBREV. DESCRIPTION ABBREV. DESCRIPTION

PC-XXX

LT-XXX

NETWORK EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

COMMUNICATION CABLE SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

ACCESS CONTROL (PACS) EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

SECURITY SYMBOL LEGEND

SYMBOL DESCRIPTION

ATTIC STOCK EQUIPMENT

MARK DESCRIPTION

COMMUNICATION EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

AUDIO/VIDEO EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

TC101

LEGENDS, DETAILS

AND SCHEDULES

C om m te ch

D es ig n

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .