About this file
This document comprises bid drawings and technical specifications for the State of Michigan's Video Management System (VMS) Upgrade project at Ionia Correctional Facility located at 1576 Bluewater Highway, Ionia, Michigan 48846. The project, designated file number 472/23198.JGH, involves comprehensive security infrastructure upgrades including installation of new security cameras, network equipment, access control systems, and electrical power infrastructure throughout multiple facility buildings. The scope encompasses new camera installations across administrative buildings, support services, education facilities, warehouse buildings, and six housing units, along with perimeter security enhancements including new camera poles with 360-degree coverage and fiber optic backbone connectivity. The drawings include detailed floor plans, electrical schematics, equipment schedules, and installation specifications prepared by Commtech Design (security systems) and Matrix Consulting Engineers (electrical work). The project requires coordination of work across multiple building systems including fire-rated wall penetrations, conduit installation, UPS power systems, and telecommunications infrastructure.
The electrical specifications detail extensive requirements for conduit routing, wire sizing, equipment grounding, surge protection devices, and compliance with the 2023 Michigan Electrical Code and MDOC standards. All work must be completed with minimal electrical outages not exceeding two hours, requiring portable generator support for perimeter detection and video management systems during switchovers. Equipment specifications include Vertiv 1500VA UPS units (model GXT5), Hanwha cameras in multiple configurations (fixed, PTZ, and 360-degree fisheye models), Genetec Streamvault archiving systems, Cisco network switches with fiber optic connectivity, and Altronix access control equipment. The document emphasizes strict security requirements including tamper-proof fasteners below ten feet, restricted conduit materials (no PVC inside buildings), and MDOC-approved equipment only. Pre-bid site visits are mandatory for contractors to assess existing conditions, and all work must adhere to facility security protocols with coordination required two weeks in advance for any electrical outages or system cutover activities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING LIST:
TC101 IONIA SECURITY LEGENDS, DETAILS, AND SCHEDULES
TC102 IONIA CONNECTIVITY CODES DETAILS
TC103 IONIA CABLING & SECURITY MOUNTING DETAILS
TC104 IONIA CABLING & SECURITY MOUNTING DETAILS
TC105 IONIA POLE MOUNTING & NEW PC DETAILS
TC106 IONIA DUAL WARDENS CONFERENCE DETAILS
TC107 IONIA FIBER BACKBONE
TC108 IONIA RACK LAYOUTS
TC109 IONIA RACK LAYOUTS
TC110 IONIA SECURITY CAMERA ONE LINE DIAGRAMS
TC111 IONIA SECURITY CAMERA ONE LINE DIAGRAMS
TC112 IONIA SECURITY CAMERA ONE LINE DIAGRAMS
TC113 IONIA SECURITY CAMERA ONE LINE DIAGRAMS
TC114 IONIA SECURITY CAMERA ONE LINE DIAGRAMS
TC115 IONIA SECURITY CAMERA ONE LINE DIAGRAMS
TC116 IONIA SECURITY CAMERA ONE LINE DIAGRAMS
TC117 IONIA SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER
TC118 IONIA SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER
TC119 IONIA ACCESS CONTROL CABLE LABELING
TC120 IONIA ACCESS CONTROL SYSTEM (PACS)
TC121 IONIA DOOR HARDWARE & SECURITY REQUIREMENTS
TC122 IONIA SYMPHONY SCHEDULE, DETAILS & REQUIREMENTS
TC301 IONIA ADMINISTRATION BLDG. 100 - ALL FLOORS - NEW AND ADDITIONAL
TC302A IONIA SUPPORT SERVICES - FIRST FLOOR - A - NEW AND ADDITIONAL
TC302B IONIA SUPPORT SERVICES - FIRST FLOOR & MEZZANINE - B - NEW AND ADDITIONAL
TC303 IONIA SUPPORT SERVICES - SECOND FLOOR - NEW AND ADDITIONAL
TC304 IONIA EDUCATION - FIRST FLOOR - NEW AND ADDITIONAL
TC305 IONIA EDUCATION - SECOND FLOOR - NEW AND ADDITIONAL
TC306 IONIA MSI - FIRST FLOOR - & MEZZANINE NEW AND ADDITIONAL
TC307 IONIA HOUSING UNIT 1 - LOWER LEVEL - NEW AND ADDITIONAL
TC308 IONIA HOUSING UNIT 1 - UPPER LEVEL - NEW AND ADDITIONAL
TC309 IONIA HOUSING UNIT 2 - LOWER LEVEL - NEW AND ADDITIONAL
TC310 IONIA HOUSING UNIT 2 - UPPER LEVEL - NEW AND ADDITIONAL
TC311 IONIA HOUSING UNIT 3 - LOWER LEVEL - NEW AND ADDITIONAL
TC312 IONIA HOUSING UNIT 3 - UPPER LEVEL - NEW AND ADDITIONAL
TC313 IONIA HOUSING UNIT 4 - LOWER LEVEL - NEW AND ADDITIONAL
TC314 IONIA HOUSING UNIT 4 - UPPER LEVEL - NEW AND ADDITIONAL
TC315 IONIA HOUSING UNIT 5 - LOWER LEVEL - NEW AND ADDITIONAL
TC316 IONIA HOUSING UNIT 5 - UPPER LEVEL - NEW AND ADDITIONAL
TC317 IONIA HOUSING UNIT 6 & 7- NEW AND ADDITIONAL
TC318 IONIA SITE PLAN - NEW AND ADDITIONAL
STATE OF MICHIGAN
IONIA CORRECTIONAL FACILITY
VIDEO MANAGEMENT SYSTEM UPGRADE
IONIA CORRECTIONAL FACILITY
1576 Bluewater Highway, Ionia, MI 48846
FILE NUMBER: 472/23198.JGH
SECURITY DESIGN
COMMTECH DESIGN
6585 BELDING RD. NE, SUITE B
ROCKFORD, MI 49341
(616) 863-8132
SECURITY DRAWING INDEX
ELECTRICAL ENGINEER
MATRIX CONSULTING ENGINEERS, INC.
544 CHERBOURG DRIVE
LANSING, MI 48917
(517) 487-2511
ELECTRICAL DRAWING INDEX
DRAWING LIST:
E-100 IONIA ELECTRICAL SYMBOLS, ABBREV. & NOTES
E-200 IONIA - SITE PLAN - POWER
E-500 IONIA - EAST - 100 ADMIN. BLDG. FIRST FLOOR - POWER
E-501 IONIA - EAST - 100 ADMIN. BLDG. SECOND FLOOR - POWER
E-502 IONIA - 200 SUPPORT SERVICES. - FIRST FLOOR - AREA B - POWER
E-503 IONIA - 200 SUPPORT SERVICES. - SECOND FLOOR - POWER
E-504 IONIA - 300 EDUCATION BLDG. - FIRST FLOOR - POWER
E-505 IONIA - 300 EDUCATION BLDG. - SECOND FLOOR - POWER
E-506 IONIA - 400 WAREHOUSE BLDG. - FIRST FLOOR - POWER
E-507 IONIA - HOUSING UNIT 1 - BASEMENT - POWER
E-508 IONIA - HOUSING UNIT 2 - BASEMENT - POWER
E-509 IONIA - HOUSING UNIT 3 - BASEMENT - POWER
E-510 IONIA - HOUSING UNIT 4 - BASEMENT - POWER
E-511 IONIA - HOUSING UNIT 5 - BASEMENT - POWER
E-512 IONIA - HOUSING UNIT 6/7 - FIRST FLOOR - POWER
E-800 ELECTRICAL DETAILS
E-801 ELECTRICAL DETAILS
COVER
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
472/23198.JGH
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text acctg template.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text 472ICFMaintproj
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 1065_24B
AutoCAD SHX Text sheet title
AutoCAD SHX Text
VIDEO SECURITY FLOOR PLANS
AutoCAD SHX Text
VIDEO MANAGEMENT SYSTEM UPGRADE
AutoCAD SHX Text
IONIA CORRECTIONAL FACILITY
AutoCAD SHX Text
IONIA, MICHIGAN
AutoCAD SHX Text Y23464
AutoCAD SHX Text
VIDEO SECURITY UPGRADES
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E CESAR E. CHAVEZ AVE.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E CESAR E. CHAVEZ AVE.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text 5/14/26
AutoCAD SHX Text
ISSUE FOR BID
AutoCAD SHX Text 5/14/26
AutoCAD SHX Text
ISSUE FOR BID
TVSS
VFD
TRANSIENT VOLTAGE SURGE SUPPRESSION
VARIABLE FREQUENCY DRIVEDUPLEX RECEPTACLE
DOCK LIGHT FIXTURE
TELEPHONE / DATA OUTLET
ELECTRICAL SYMBOLS LEGEND
J
SINGLE RECEPTACLE (120 VOLT)
EMERGENCY RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
FLUSH FLOOR BOX
SURFACE FLOOR BOX
SPECIAL EQUIPMENT RECEPTACLE
TELEPHONE OUTLET
DATA OUTLET
POWER POLE
JUNCTION BOX
WALL JUNCTION BOX
PULL (JUNCTION) BOX
UNDERFLOOR JUNCTION BOX
OUTLETS
LIGHT FIXTURE
STRIP FIXTURE
IN-GRADE LIGHT FIXTURE
SPOTLIGHT (number of heads shown) EXIT SIGN (face & direction as shown)
WALL MOUNT LIGHT FIXTURE
CEILING LIGHT FIXTURE
TRACK & FIXTURE
STREET TYPE POLE FIXTURE
POLE MOUNTED LIGHT FIXTURE
EXTERIOR WALL MOUNT LIGHT FIXTURE
WALLPACK LIGHT FIXTURE
SPECIAL PURPOSE LIGHT FIXTURE
HIGH BAY LIGHT FIXTURE
EMERGENCY EGRESS LIGHT FIXTURE
(number of heads shown)
EMERGENCY LIGHT FIXTURE
FIXTURES
CIRCUITRY and RACEWAYS
UNDERFLOOR DUCT
BUS DUCT
PLUGMOLD AS SPECIFIED
WIREMOLD AS SPECIFIED
FLEXIBLE PIGTAILS/CONNECTIONS
"CONDUIT RUN CONTINUES" INDICATION
END OF CONDUIT RUN, CAP AND STAKE
END OF CONDUIT RUN
HOME RUN (with circuit numbers)
CONDUIT STUB DOWN
CONDUIT STUB UP
CONDUIT INSTALLED
CONDUIT INSTALLED
SOUND and SIGNAL
SERVICE and EQUIPMENT
THERMOSTAT
CAPACITOR
ENCLOSED CIRCUIT BREAKER
TRANSFER SWITCH
WIREWAY
GROUND CONNECTION PER N.E.C.
TELEPHONE TERMINAL BOARD
GENERATOR, KW SHOWN
CURRENT TRANSFORMERS
UTILITY METER, AS REQUIRED
WEATHERHEAD
PANELBOARD, FLUSH MOUNTED
PANELBOARD, SURFACE MOUNTED
COMB. STARTER
MAGNETIC STARTER
DISCONNECT SWITCH
TRANSFORMER
CONTROL
xxVA connection by x/C) IRRIGATION CONTROLLER (120 volt
LIGHTING CONTACTOR
CONTROL TRANSFORMER
buttons indicated) PUSHBUTTON STATION (number of TIME CLOCK (24 hour U.O.N.)
PHOTOCELL (voltage as required)
HUMIDISTAT
(by E.C.)
(by others)
TT
G
WW
PC
CT
TS
T
H
TC
IC
T
1,3
OR
PM
WM
BD
UFD
F S
J
J
PP
J
CEILING MOUNTED WIFI
DIGITAL EQUIPMENT METER, AS REQUIRED
POLE
PUMP
PANEL
P
PNL
PVC
PRV-
P-
PB
POLY VINYL CLORIDE
POWER ROOF VENTILATOR
PULL BOX
GENERAL CONTRACTOR
GROUND
HUMIDIFIERH-
GND
GFI
GC
GROUND FAULT INTERUPTER
ABBREVIATIONS LEGEND
POWER
SWITCH
RECEPT
SF-
SWBD
TCC
SPEC
SW
RGC
RTU-
PWR
VOLTS
WATTS
UF
V
W
UL
VL
UNO
UH-
TS
TYP
TR
ROOF TOP UNIT
RECEPTACLE
SWITCHBOARD
UNDER FLOOR
SPECIFICATIONS
RIGID GALVANIZED STEEL CONDUIT
UNLESS NOTED OTHERWISE
UNDERWRITERS' LABORATORIES, INC.
TAMPER PROOF RECEPTACLE
TAMPER PROOF SWITCH
TEMPERATURE CONTROL CONTRACTOR
VERIFY LOCATION WITH OWNER
TYPICAL
UNIT HEATER
SUPPLY FAN
WITH
WITHOUT
W/
XFMR
W/O
WP
TRANSFORMER
WEATHER PROOF
HOUR
LIGHT
JUNCTION BOX
LIGHT CONTROL
ISOLATED GROUND
HORSEPOWER
MINIMUM
MOUNT
MAKE-UP AIR UNIT
MOTOR CONTROL CENTER
MAIN LUG ONLY
MOUNTED
MOUNTING
MAXIMUM
LIGHTING
LT FLEX
MTD
MUAU-
MTG
MLO
MIN
MT
MC
MAX
MCC
LTG
IG
LC
LT
IMC
JB
HR
HVAC
HOA
HP
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
NIGHT LIGHTNL
NTS
NO
NIC
NC
HAND-OFF-AUTO SELECTOR SWITCH
HEATING/VENTILATING/AIR CONDITIONING
INTERMEDIATE METAL CONDUIT
LIQUID TIGHT FLEXIBLE METAL CONDUIT
MECHANICAL CONTRACTOR
HID HIGH INTENSITY DISCHARGE
A
AC
AFF
ACU-
AHJ
AHU-
AS
B-
BC
AIC
ATS
BLDG
CHLR-
CND (C)
CKT BKR
CKT
CUH-
CU-
DISC
DFU-
EF-
EC
DWH-
EBB-
DWG
CT-
EXIST (E)
EWC
FLEX
FLA
FLR
FSES
FLUOR
EMT
ABOVE FINISHED FLOOR
AIR CONDITIONING UNIT
AMPS
ABOVE COUNTER
AIR HANDLING UNIT
AUTOMATIC TRANSFER SWITCH
AMPS INTERUPTING CAPACITY
AUTHORITY HAVING JURISDICTION
ABOVE SHELF
BOILER
BUILDING
BELOW COUNTER
CHILLER
DOMESTIC WATER HEATER
CABINET UNIT HEATER
CIRCUIT
CIRCUIT BREAKER
CONDUIT
CONDENSING UNIT
COOLING TOWER
DUCT FURNACE
DRAWING
DISCONNECT
FOOD SERVICE EQUIP. SUPPLIER
ELECTRIC WATER COOLER
ELECTRICAL CONTRACTOR
ELECTRIC BASEBOARD
ELECTRICAL METALLIC TUBING
EXISTING
EXHAUST FAN
FLOOR
FLUORESCENT
FLEXIBLE CONDUIT
FULL LOAD AMPS
EM EMERGENCY
F/S FIRE/SMOKE
FU- FURNACE
SSCP
COCCTV
SECURITY SYSTEM CONTROL PANEL
CAMERA
DATA RACK
RACK MOUNTED UPS
BRACKET MOUNTED UPS
NEW 1500VA UPS- EQUIPMENT SPECIFICATION
1500VA UNINTERRUPTIBLE POWER SUPPLY (UPS) - VERTIV GXT5
PROVIDE UNINTERRUPTIBLE POWER SUPPLY (UPS). UPS SHALL BE
1.5KVA RATED, HIGH EFFICIENCY, DOUBLE CONVERSION, CONTINUOUS
DUTY, ON-LINE TYPE. INPUT VOLTAGE OF 120VAC, 60HZ, 1-PHASE, 3-WIRE
PLUS GROUND. OUTPUT VOLTAGE OF 120VAC, 60HZ, 1-PHASE, 4-WIRE
PLUS GROUND. INCLUDE ALARM RELAY BOARD FOR REMOTE
MONITORING, LITHIUM ION BATTERIES, 13 MINUTE RUN TIME, SELF
DIAGNOSTICS. NEMA 5-15 PLUG WITH (6) NEMA 5-15R RECEPTACLES.
INCLUDE A VERTIV WALL MOUNT BRACKET, PART NUMBER WMBKT2U,
WHERE SHOWN IN DRAWINGS.
INCLUDE 5 YEAR ON-SITE WARRANTY SERVICE FOR PARTS AND LABOR.
SEQUENCE OF EQUIPMENT INSTALL:
1. INSTALL NEW WALL MOUNT BRACKET IF APPLICABLE.
2. INSTALL NEW 1500VA BRACKET OR RACK MOUNTED UPS AS SHOWN
IN DRAWINGS.
3. RELOCATE CAMERA EQUIPMENT POWER TO NEW UPS.
4. REMOVE OLD UPS.
POLE
POLE
HOW HIGH ON WALL
DR
RUPS
BUPS
P
C
X
X
X ADDENDUM NOTE
PLAN NOTE
DEMOLITION NOTE
SWITCHES
SINGLE-POLE SWITCH
DIMMER SWITCH
TIME SWITCH
KEY SWITCH
MANUAL MOTOR SWITCH
THERMAL OVERLOAD SWITCH
SWITCH WITH PILOT LIGHT
FOUR-WAY SWITCH
THREE-WAY SWITCH
DESIGNATIONS
D
PLUG STRIP (PDU)
DESCRIPTION AND COMMENTSTYPE MANUFACTURER CATALOG NO.
NEW CAMERA POLE SCHEDULE
DS210-590A200-D1PC-FPDB-FBC-AB - POLE
LDV05-1C-06ARM-HMLED4LUM-P3-KPHASE-70-AG-LAJB - TRUSS
18' TAPERED STEEL POLE WITH BASE, 2" X 4" HAND HOLE AT 18" FROM
THE BASE TO HAND HOLE, ANCHOR BOLTS PER MANUFACTURE
RECOMMENDATIONS, TRUSS TO SUPPORT (1) 360 DEGREE TYPE
CAMERA CENTERED OVER SALLY PORT DRIVE. BRONZE FINISH.
VALMONT
OR PSC APPROVED
EQUAL
DATA RACK
(4) #10 AWG
(1) #10 GND
(1) 3/4" CND
VERTIV PART NUMBER I10087, OR
PRE-APPROVED EQUAL, MOUNTED ON
DATA RACK OR CABLE LADDER. REFER TO
FLOOR PLANS FOR DEVICE COLOR .
ARCHIVER PDU DETAIL
SCALE: N.T.S.1
(4) #10 AWG
(1) #10 GND
(1) 3/4" CND
REFER TO
FLOOR PLANS
FOR (2)
CIRCUITS
VERTIV PART NUMBER I10087, OR
PRE-APPROVED EQUAL, MOUNTED ON
DATA RACK OR CABLE LADDER. REFER TO
FLOOR PLANS FOR DEVICE COLOR .
DIRECTORY
DIRECTORY
CONNECT ARCHIVERS AND DIRECTORIES
TO RACK MOUNTED PDU'S. REFER TO
COMMTECH DRAWINGS FOR RACK
LAYOUT.
ADMIN PDU DETAIL
SCALE: N.T.S.2
DATA RACK
(2) #12 AWG
(1) #12 GND
(1) 3/4" CND
VERTIV PART NUMBER 38607, OR
PRE-APPROVED EQUAL, MOUNTED ON
DATA RACK OR CABLE LADDER. DEVICE
COLOR IN ADMINISTRATION BUILDING
SHALL BE BLUE, ALL OTHER DEVICES
SHALL BE RED.
REFER TO
FLOOR
PLANS
(2) #12 AWG
(1) #12 GND
(1) 3/4" CND
REFER TO
FLOOR
PLANS
ARCHIVER
ARCHIVER
ARCHIVER
ARCHIVER
ARCHIVER
ARCHIVER
ARCHIVER
BLUE 30A L21-30R TWISTLOCK
RECEPTACLE
BLUE 30A L21-30R TWISTLOCK
RECEPTACLE
20A L5-20R TWISTLOCK
RECEPTACLE
20A L5-20R TWISTLOCK
RECEPTACLE
RACK MOUNTED RECEPTACLE AND UPS DETAIL
SCALE: N.T.S.3
DATA RACK
(2) #12 AWG
(1) #12 GND
(1) 3/4" CND
REFER TO
FLOOR
PLANS
20A RED QUAD RECEPTACLE
FROM GENERATOR POWER.
MOUNT ON RACK.
1500VA UPS
GENERAL ELECTRICAL NOTES
ALL WORK SHALL BE IN COMPLIANCE WITH THE 2023 MICHIGAN
ELECTRICAL CODE AND MDOC STANDARDS.
1. ALL NON-FIRE RATED WALLS ARE TO BE PATCHED WITH LIKE
MATERIAL TO MAINTAIN ORIGINAL RATING.
2. ALL WALL AND FLOOR PENETRATIONS THROUGH FIRE RATED WALLS
ARE TO BE SEALED WITH FIRE CAULK TO MAINTAIN ORIGINAL
RATING. EXISTING PENETRATIONS IN THE AREA OF WORK THAT ARE
NOT PROPERLY SEALED ARE TO BE SEALED TO MATCH THE RATING
OF THE WALL.
3. ALL CONDUITS SHALL BE FIELD ROUTED ALONG EXISTING PIPING
AND STRUCTURAL STEEL. CONDUITS SHALL BE INSTALLED
STRAIGHT, LEVEL, AND PARALLEL OR PERPENDICULAR TO THE
BUILDING LINES.
4. CONTRACTORS SHALL VISIT THE PROJECT SITE DURING PRE-BID
WALK THROUGH TO DETERMINE THE EXACT EXTENT OF THE WORK
REQUIRED BEFORE BIDDING THE PROJECT.
5. REMOVE ALL EXISTING OBSOLETE EXPOSED CONDUIT, WIRE, AND
EQUIPMENT NOT TO BE RE-USED WHERE WORK IS BEING DONE
EXCEPT ITEMS NOTED OTHERWISE.
6. WHERE BUILDING SURFACES ARE DAMAGED BY THE REMOVAL OF
OLD WORK, SURFACES SHALL BE PATCHED AND PAINTED TO MATCH
ADJACENT.
7. EXISTING WORK, WHICH IS PRESENTLY CONCEALED, WHICH WILL
REMAIN CONCEALED, AND DOES NOT INTERFERE WITH ANY NEW
WORK OF ANY TRADE NEED NOT BE REMOVED. HOWEVER, ALL
CONDUIT SHALL BE CAPPED BELOW FINISH SURFACE AND THEN
PATCHED AND PAINTED TO MATCH, OR AS NOTED.
8. EXISTING OPENINGS, WHICH ARE TO BE REUSED, SHALL BE
MODIFIED OR ENLARGED TO SUIT THE NEW SYSTEMS AS REQUIRED.
PROVIDE ALL REQUIRED CUTTING AND PATCHING.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING THE EXISTING
WALLS TO MATCH THE ADJACENT SURFACES BEHIND ALL SURFACE
MOUNTED EQUIPMENT.
10. CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT AND LOADS
PRIOR TO INSTALLING SERVICE TO EQUIPMENT.
11. DRAWINGS ARE BASED ON EXISTING RECORD DOCUMENTS AND
CASUAL FIELD OBSERVATION. REPORT ANY DISCREPANCIES TO
ENGINEER FOR CLARIFICATION.
12. CONDUITS AND BOXES:
12.1. 3/4" MINIMUM TRADE SIZE.
12.2. EMT TYPE CONDUIT IS APPROVED WITH COMPRESSION
FITTINGS.
12.3. NO PVC ALLOWED INSIDE OF BUILDINGS.
12.4. CONDUITS SHALL BE ATTACHED WITH TWO-HOLE STRAPS.
SINGLE HOLE STRAPS ARE NOT PERMITTED.
12.5. NO SET SCREWS ARE ALLOWED.
12.6. TAMPER-PROOF SCREWS REQUIRED FOR EXPOSED CONDUIT
AND BOXES MOUNTED BELOW TEN FEET.
12.7. DRIVE PIN ANCHORS USED ON MASONARY OR CONCRETE
WALLS/CEILINGS.
13. MINIMUM RACEWAY SIZE; 3/4" TRADE SIZE. ALL FLEXIBLE CONDUIT
RACEWAYS SHALL BE LIQUID TITE, MAXIMUM 72" LENGTH AND MUST
BE APPROVED BY PSC AND MDOC PROJECT MANAGER. REFER TO
SPECIFICATION 260533 - RACEWAY AND BOXES FOR ELECTRICAL
SYSTEMS.
14. INSTALLATION OF ANY NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW CURRENT NEC AND MDOC STANDARDS.
15. CONDUIT, CONDUIT INSTALLATION, AND BOXES BEING REUSED
SHALL BE BROUGHT UP TO CURRENT MDOC STANDARDS.
16. ALL CONDUIT AND BOXES ABOVE 10 FOOT OR IN
MECHANICAL/ELECTRICAL ROOMS, SHALL MEET THE FOLLOWING
REQUIREMENTS:
16.1. STRAP DISTANCE: 5 FEET.
16.2. FASTENERS: 2 HOLE.
16.3. CONDUIT” INTERIOR EMT, EXTERIOR EXPOSED/CONCEALED-
GRC.
16.4. FITTINGS: COMPRESSION.
16.5. BOXES: STANDARD BOXES FOR ENVIORNMENT INSTALLED TO
MEET N.E.C.
16.6. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND
ENCLOSURES.
17. ALL CONDUIT AND BOXES 10 FOOT AND BELOW SHALL MEET THE
FOLLOWING REQUIREMENTS:
17.1. STRAP DISTANCE: 3 FEET.
17.2. FASTENERS: 2 HOLE WITH SECURITY SCREWS.
17.3. SECURITY HARDWARE:
17.3.1. TORX T-25 WITH CENTER REJECTION PIN.
17.3.2. HEX HEAD CONCRETE SCREWS WITH NO SCREWDRIVER
SLOT.
17.3.3. EXPANSION POUND-IN ANCHORSWITH NO SCREWDRIVER
SLOT THAT DO NOT REQUIRE TO BE EXPLOSIVELY DRIVEN.
17.3.4. PRE-APPROVED HARDWARE.
17.4. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED -
GRC.
17.5. FITTINGS: COMPRESSION
17.6. BOXES:
17.6.1. SURFACE MOUNTED:
17.6.1.1. BELL BOX: FS TYPE, WITH SQUARE HEAD KO SEAL.
17.6.1.2. NO KNOCKOUTS - DRILL AS REQUIRED.
17.7. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND
ENCLOSURES.
18. ALL EXPOSED WIRING SHALL BE IN CONDUIT. OPEN LOW VOLTAGE
WIRING ABOVE ACCESIBLE CEILINGS IS ACCEPTABLE.
18.1. ALL EXPOSED WIRING ABOVE CEILINGS SHALL BE INSTALLED
WITH J-HOOKS. DO NOT CONNECT TO EXISTING CEILING TIE
WIRES.
19. ALL WALLS THAT ARE ACCESSIBLE SHALL BE FISHED AND DEVICE
CUT INTO WALL.
20. ALL LOCATIONS WHERE THE WALLS CAN NOT BE FISHED SHALL BE
SURFACE MOUNTED CONDUIT FOLLOWING NOTES 14 THROUGH 15
ABOVE.
21. ALL EXTERIOR CONCEALED CONDUIT UNDERGROUND SHALL BE
RNC/HDPE SCHEDULE 80. ALL EXTERIOR ABOVE GROUND CONDUIT
SHALL BE RGC UP TO 10 FEET ABOVE GRADE. PROVIDE UL LISTED
#12 COPPER TRACER WIRE TO ALL UNDERGROUND CONDUITS
INSTALLED FOR LOW VOLTAGE.
22. ALL ELECTRICAL OUTAGES SHALL NOT LAST OVER 2-HOURS. IF A
WINDOW OF GREATER THAN 2 HOURS FOR AN ELECTRICAL SHUT
DOWN OR CUT OVER IS REQUIRED, THEN A PORTABLE GENERATOR
SHALL BE USED TO REPLACE POWER TO ALL PERIMETER DETCTION,
VIDEO MANAGEMENT, LINE SAFTEY, AND ANY OTHER ELECTRICAL
SERVICE REQUIRED. ALL OUTAGES AND CUT OVERS SHALL BE
COORDINATED A MINIMUM OF 2-WEEKS PRIOR TO WORK, INCLUDING
AN HOUR BY HOUR SCHEDULE, MUST BE SUBMITTED TO MDOC
LEADERSHIP AND THE FACILITY FOR REVIEW.
23. WHEN RELOCATING ANY ELECTRICAL DEVICE, CONTRACTOR SHALL
COMPLETE THE RELOCATION IN ONE DAY AND VERIFY THAT ALL
DEVICES RELOCATED ARE WORKING PROPERLY PRIOR TO LEAVING
THE SITE.
24. CONTRACTOR SHALL PROVIDE AND INSTALL ALL REQUIRED
COMPONENTS, RACEWAYS, WIRE, AND HARDWARE, AS INDICATED
ON DRAWINGS.
25. CONTRACTOR SHALL PROVIDE UPDATED PANEL SCHEDULES FOR
ALL PANELS AFFECTED BY THIS PROJECT. UPDATED SCHEDULES
SHALL BE PRINTED AND INSTALLED ON THE INSIDE COVER OF THE
PANEL.
26. ALL WORK COMPLETED WITHOUT APPROVED SHOP DRAWINGS IS AT
CONTRACTOR'S RISK.
27. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF
ALL 24V CONTROL WIRING AS REQUIRED TO LOCALLY CONTROL ALL
HVAC & PLUMBING IN ACCORDANCE WITH THE SEQUENCE OF
OPERATIONS. REFER TO THE MECHANICAL DRAWINGS FOR ALL
LOCAL THERMOSTAT LOCATIONS AND MECHANICAL SPECIFICATIONS
FOR INSTALLATION REQUIREMENTS. COORDINATE IN FIELD WITH
MECHANICAL CONTRACTOR AS REQUIRED. ELECTRICAL
CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUIT, WIRE,
AND HARDWARE AS REQUIRED IN ACCORDANCE WITH ELECTRICAL
SPECIFICATIONS. REFER TO SHEET E-100 DETAIL 1 FOR ADDITIONAL
INFORMATION.
28. CONTRACTOR SHALL NOTIFY PSC OF ANY EXISTING INSTALLATIONS
NOT MEETING THESE STANDARDS PRIOR TO STARTING WORK IN THE
AREA.
29. UPON RELOCATING LIGHTS AND CAMERAS CONTRACTORS SHALL
VERIFY THAT THE LIGHTS AND CAMERAS ARE WORKING PROPERLY
PRIOR TO LEAVING THE SITE.
30. CONTRACTOR SHALL USE MDOC APPROVED POLES AND FIXTURES,
NO ALTERNATES WILL BE ALLOWED. ALL OTHER STATE OF MICHIGAN
AGENCY SPECIFICATIONS DO NOT APPLY.
31. CONTRACTOR SHALL NOT ADD MORE THAN 20% CAPACITY TO ANY
PANEL.
32. ARC FLASH LABELS TO BE PROVIDED FOR ALL NEW PANELBOARDS.
33. NEW PRINTED CIRCUIT DIRECTORIES SHALL BE PROVIDED FOR ALL
NEW AND REVISED PANELBOARDS.
34. CONTRACTOR SHALL SUBMIT AN RFI FOR ANY NON-CODE
COMPLIANT ELECTRICAL EQUIPMENT OR ELECTRICAL INSTALLATION.
AN RFI RESPONSE WILL BE PROVIDED GIVING DIRECTION ON HOW
TO PROCEED.
E-100
DRK
JFS
WEST SITE PLAN
POWER
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
5/14/26 ISSUE FOR BID
C
C
C C
C
C
C
C
C
C
C
C C
C
C
C
C
C C
C C
C
C
C
C
PL-017
PL-018
PL-019
PL-020
PL-021
PL-022
PL-023
PL-024
PL-025
PL-026
PL-027
PL-028
PL-029
PL-030
PL-031
PL-032
PL-033
PL-034
PL-035
PL-036
PL-037
PL-038PL-039
PL-039B
PL-001
PL-002
PL-003
PL-004
PL-005
PL-006
PL-007
PL-008
PL-009
PL-010
PL-011
PL-012
PL-013
PL-014 PL-015
PL-016
PL-001B
PL-039A
PL-016A
PL-008A
PL-027A
PL-033A
PL-001A
C
C
C
C
C
C C
C
C
C C
C
C
C C C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
CC
CC
C
C
C
C
C
C
C
C
C
C
C
C C
C P
2 2
(1) 1" CND
(1) 1" CND
(1) 1" CND
C2
C2
C
C 2
C 2
C
C
C
C
5 6
C
C 2
C 2C
C C
(1) 1" CND
ELECTRICAL KEY NOTES
PROVIDE AND INSTALL NEW SURGE PROTECTION DEVICES
AND JUNCTION BOX FOR CAMERAS ON POLE. ALL POLES ARE
EXISTING TO REMAIN UNLESS OTHERWISE SPECIFIED. REFER
TO SHEET E-800 DETAIL 3.
PROVIDE AND INSTALL NEW SURGE PROTECTION DEVICE IN
COMMUNICATIONS ROOM FOR CAMERAS ON BUILDING.
REFER TO SHEET E-800 DETAIL 2.
REMOVE EXISTING SURGE PROTECTION DEVICES AND
HORNER LIGHTING CONTROLS. PROVIDE AND INSTALL NEW
SURGE PROTECTION DEVICES IN PERIMETER CABINET
(RAYCAP G29-00-394-OTL-PROTEC-T1-40 AND RAYCAP
NJ2010B). REFER TO SHEET E-800 DETAIL 1. REMOVE ALL
HARDWARE AND EXPOSED WIRING FROM THE CABINET AND
MAKE SAFE.
PROVIDE AND INSTALL NEW POLE AND BASE FOR NEW 360
DEGREE SALLY PORT DRIVE CAMERA. REFER TO SHEET E-801
DETAILS 3&4 AND POLE SCHEDULE ON SHEET E-100.
PROVIDE AND INSTALL NEW NEMA 3R RATED JUNCTION BOX
ON THE EXTERIOR WALL OF BUILDING. LOCATE THE
JUNCTION BOX OUTSIDE THE COMMUNICATIONS ROOM.
DIRECTIONALLY BORE CONDUIT TO JUNCTION BOX ON
EXTERIOR WALL OF BUILDING AS SHOWN. REFER TO LOW
VOLTAGE DRAWINGS FOR CABLE TYPE AND QUANTITY.
PROVIDE AND INSTALL NEW NEMA 3R RATED JUNCTION BOX
ABOVE CAGE FOR NEW CAMERAS. REFER TO LOW VOLTAGE
DRAWINGS FOR DETAILS.
EXISTING LIGHT FIXTURES
EXISTING STEEL POLE
GRADE GRADE
EXISTING HANDHOLE
FROM NEXT POLE/CABINET
36"
GROUND WIRE
SPLICE CABLE
JUNCTION BOX
TO CABINET
EXIST. CONDUIT
AND WIRE FOR
LIGHT FIXTURE
POWER
SCALE: N.T.S.
TYPICAL EXISTING LIGHT POLE DETAIL DEMOLITION
EXISTING LIGHT
FIXTURE WIRE
EXISTING LIGHT
FIXTURE CONTROL
WIRE
EXISTING LIGHT FIXTURE POLE AND FIXTURE HEADS TO REMAIN. EXISTING
LIGHT FIXTURE WIRE TO REMAIN. DISCONNECT AND REMOVE EXISTING
LIGHT FIXTURE CONTROL CONDUIT AND WIRE BACK TO SOURCE.
DISCONNECT AND REMOVE LIGHTING CONTROL RELAY LOCATED AT BASE
OF POLE. EXISTING JUNCTION BOX TO REMAIN.
DEMOLITION NOTES
E-200
JJD
JFS
SITE PLAN
POWER
N ELECTRICAL - SITE PLAN - POWER
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
5/14/26 ISSUE FOR BID
SCALE: 1" = 60'-0"
400 10 20 80 150
SUPPORT SERVICES
EX
EX
EXEX
EX
EX
EX
EX
EX
EX
1 1
UPS-A-24
UPS-A-26 UPS-A-28
UPS-A-30
UPS-A-38
UPS-A-36
UPS-A-36
J
UPS-A-32
UPS-A-34
ELECTRICAL KEY NOTES
PROVIDE AND INSTALL NEW 20A BLUE QUAD RECEPTACLE
FROM PANEL "UPSA".
PROVIDE AND INSTALL CONDUIT AND WIRE FOR NEW
CONFERENCE TABLE RACEWAY. REFER TO LOW VOLTAGE
DRAWINGS FOR MORE DETAILS.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
E-500
JFS
EAST 100 ADMIN - FIRST
FLOOR
N
ELECTRICAL - EAST 100 ADMIN FLOOR PLAN - FIRST
FLOOR - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
5/14/26 ISSUE FOR BID
JJD
CAPTAIN'S OFFICE
INSPECTOR
OFFICE
HEARING'S
INVESTIGATOR
INSPECTOR
OFFICE
ASSISTANT
DEPUTY WARDEN
OFFICE
DEPUTY
WARDEN
DR
DR
EX PANEL "UPS-A"
120/208V-3Ø, 100A DR
EX 30KVA UPS
TEX 30KVA XFMR
TL
TL
TL
TL
TL
TL
EX PANEL "MPB"
480V-3Ø, 600A
EX PANEL "UPS"
480V-3Ø, 30A
TEX
EX PANEL "L-RPX"
120/208V-3Ø, 100A
EX PANEL "RPX"
120/208V-3Ø, 100A
EX PANEL "LP-XA"
277V-3Ø, 100A
REPLACED PANEL "RP-A"
120/208V-3Ø, 100A
EX PANEL "LP-ZA"
277V-3Ø, 100A
EX PANEL "LP-BB"
277V-3Ø, 100A
EX PANEL "EMPB"
480V-3Ø, 100A
UPS-A-19,21,23
UPS-A-25,27,29
UPS-A-31
UPS-A-33
RP-A-43
UPS-A-35
RP-A-45
RP-A-47
DR
TL
TL
ELECTRICAL KEY NOTES
PROVIDE AND INSTALL (2) NEW BLUE 30A L21-30R TWISTLOCK
RECEPTACLE FROM UPS POWER. CONNECT TO SEPARATE
VERTICAL POWER STRIPS ON BACK OF RACK. PROVIDE AND
INSTALL ALL CONDUIT WIRE AND HARDWARE AS REQUIRED.
REFER TO SHEET E-100 DETAIL 1.
PROVIDE AND INSTALL (1) NEW BLUE 20A TWISTLOCK
RECEPTACLE FROM UPS POWER AND (1) NEW RED 20A
TWISTLOCK RECEPTACLE FROM GENERATOR POWER.
CONNECT TO SEPARATE VERTICAL POWER STRIPS ON BACK
OF RACK. PROVIDE AND INSTALL ALL CONDUIT WIRE AND
HARDWARE AS REQUIRED. REFER TO SHEET E-100 DETAIL 2.
PROVIDE AND INSTALL (2) VERTIV I10087 POWER STRIPS ON
THE BACK OF THE RACK. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL (2) VERTIV 38607 POWER STRIPS ON
THE BACK OF THE RACK. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL NEW LINE VOLTAGE SURGE
PROTECTION DEVICE IN PANEL (RAYCAP
RSE-2-277-3Y-A-10-E-F-S).
PROVIDE AND INSTALL NEW LINE VOLTAGE SURGE
PROTECTION DEVICE IN PANEL (RAYCAP
RSE-2-277-3Y-A-5-E-F-S).
DISCONNECT AND REMOVE EXISTING HORNER LIGHTING
CONTROL SERVER. REMOVE ASSOCIATED CONDUIT AND
WIRE. PROVIDE AND INSTALL NEW LIGHTING CONTROL
OVERRIDE SWITCH IN THIS AREA. CONNECT TO EXISTING
ULTRALINK SYSTEM. CONTRACTOR SHALL VERIFY FINAL
LOCATION WITH OWNER PRIOR TO INSTALLATION.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
E-501
JFS
EAST 100 ADMIN - SECOND
FLOOR
N
ELECTRICAL - EAST 100 ADMIN FLOOR PLAN - SECOND
FLOOR - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
JJD
AREA B
AREA B
AREA A
AREA A
BU
PS
RP-E-35
ELECTRICAL KEY NOTES
REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL
NEW 1500VA BRACKET MOUNTED UPS FOR CAMERA PC AND MONITOR.
PROVIDE AND INSTALL ALL CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. CONNECT TO 1500VA
UPS UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
RU
PS
E-502
JFS
200 SUPPORT SERVICES -
AREA B - FIRST FLOOR
N
ELECTRICAL - 200 SUPPORT SERVICES FLOOR PLAN -
FIRST FLOOR - AREA B - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
5/14/26 ISSUE FOR BID
KEY PLAN
JJD
N
ELECTRICAL - 200 SUPPORT SERVICES FLOOR PLAN -
MEZZANINE - AREA B - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
RUPS
PANEL RP-E
120/208V-3Ø, 100A
RP-E-37
ELECTRICAL KEY NOTES
REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
E-503
JFS
200 SUPPORT SERVICES -
SECOND FLOOR
N
ELECTRICAL - 200 SUPPORT SERVICES FLOOR PLAN -
SECOND FLOOR - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
BUPS
EX PNL EMPB
480/277V-3Ø, 200A
EX PNL MPB
480/277V-3Ø, 600A
EX PNL LP-XX
480/277V-3Ø, 60A
EX PNL RPX
120/208V-3Ø, 100A
TEX
TEX
EX PNL RPD
120/208V-3Ø, 100A
EX PNL RPF
120/208V-3Ø, 100A
1 RPD-25
EX PNL LP-ZZ
480/277V-3Ø
RU
PS2
RPD-29
ELECTRICAL KEY NOTES
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE AND 1500VA BRACKET
MOUNTED UPS FOR NEW SECURITY EQUIPMENT. MOUNT ABOVE DOOR.
PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND BREAKERS AS
REQUIRED.
REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
E-504
JFS
300 EDUCATION BLDG -
FIRST FLOOR
N
ELECTRICAL - 300 EDUCATION BLDG FLOOR PLAN -
FIRST FLOOR - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
RU
PS
RPD-27
RPD-27
BUPS
ELECTRICAL KEY NOTES
REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE AND 1500VA BRACKET
MOUNTED UPS FOR NEW SECURITY EQUIPMENT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, HARDWARE, AND BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
E-505
JFS
300 EDUCATION BLDG -
SECOND FLOOR
N
ELECTRICAL - 300 EDUCATION BLDG FLOOR PLAN -
SECOND FLOOR - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
RUPS1
EXISTING 30KVA UPS
EX PANEL "LPA"
277/480V-3Ø, 225A
EX PANEL "UPS"
277/480V-3Ø, 60A
EX SUB PANEL
120/208V-3Ø, 100A
EX PANEL "E"
120/208V-3Ø, 30A
EX PANEL "YA"
277/480V-3Ø, 225A
EX PANEL "LPEE"
277/480V-3Ø, 225A
EX SW "M-MDP"
277/480V-3Ø
E-13
ELECTRICAL KEY NOTES
REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
E-506
JFS
400 WAREHOUSE BLDG -
FIRST FLOOR
N
ELECTRICAL - 400 WAREHOUSE BLDG FLOOR PLAN -
FIRST FLOOR - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
5/14/26 ISSUE FOR BID
JJD
ELECTRICAL - MSI BLDG 400 - FLOOR PLAN
400 MSI BLDG.
277/480V-30, 60A
"UPS"
277/480V-30, 60A
"UPS"
120/208V-30, 100A
"UPS"
ELECTRICAL KEY NOTES
REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
RUPS
EX SW "EM"
480/277V-3Ø, 225A
EX PANEL "H2"
120/208V-3Ø, 100A
EX PANEL "H"
120/208V-3Ø, 100A
EX PANEL "LPH"
480/277V-3Ø, 100A
EX SW "H-MDP"
480/277V-3Ø, 225A
EX PANEL "EH"
120/208V-3Ø, 50A
EH-34
E-507
JFS
HOUSING UNIT 1
BASEMENT
N
ELECTRICAL - HOUSING UNIT 1 FLOOR PLAN -
BASEMENT - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
A-X
MECH.BOILERROOM
A-1
CENTERSTAIR
EX SW "EM"
480/277V-3Ø, 225A
EX PANEL "H2"
120/208V-3Ø, 100A
EX PANEL "H"
120/208V-3Ø, 100A
EX PANEL "LPH"
480/277V-3Ø, 100A
EX SW "H-MDP"
480/277V-3Ø, 225A
EX PANEL "EH"
120/208V-3Ø, 50ARUPS
EH-34
E-508
JFS
HOUSING UNIT 2
BASEMENT
N
ELECTRICAL - HOUSING UNIT 2 FLOOR PLAN -
BASEMENT - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
EX SW "EM"
480/277V-3Ø, 225A
EX PANEL "H2"
120/208V-3Ø, 100A
EX PANEL "H"
120/208V-3Ø, 100A
EX PANEL "LPH"
480/277V-3Ø, 100A
EX SW "H-MDP"
480/277V-3Ø, 225A
EX PANEL "EH"
120/208V-3Ø, 50ARUPS
EH-36
E-509
JFS
HOUSING UNIT 3
BASEMENT
N
ELECTRICAL - HOUSING UNIT 3 FLOOR PLAN -
BASEMENT - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
EX SW "EM"
480/277V-3Ø, 225A
EX PANEL "H2"
120/208V-3Ø, 100A
EX PANEL "H"
120/208V-3Ø, 100A
EX PANEL "LPH"
480/277V-3Ø, 100A
EX SW "H-MDP"
480/277V-3Ø, 225A
EX PANEL "EH"
120/208V-3Ø, 50ARUPS
EH-32
ELECTRICAL KEY NOTES
REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
E-510
JFS
HOUSING UNIT 4
BASEMENT
N
ELECTRICAL - HOUSING UNIT 4 FLOOR PLAN -
BASEMENT - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
EX SW "EM"
480/277V-3Ø, 225A
EX PANEL "H2"
120/208V-3Ø, 100A
EX PANEL "H"
120/208V-3Ø, 100A
EX PANEL "LPH"
480/277V-3Ø, 100A
EX SW "H-MDP"
480/277V-3Ø, 225A
EX PANEL "EH"
120/208V-3Ø, 50ARUPS
EH-35
E-511
JFS
HOUSING UNIT 5
BASEMENT
N
ELECTRICAL - HOUSING UNIT 5 FLOOR PLAN -
BASEMENT - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
JJDJJD
RUPS
EX PANEL "EG"
120/208V-3Ø, 100A
EX PANEL "EG-1"
120/208V-1Ø, 70A
EX PANEL "B"
120/208V-3Ø, 225A
EX PANEL "A"
120/208V-3Ø, 225A
EG-1-10
ELECTRICAL KEY NOTES
REMOVE ANY AND ALL CAMERA SYSTEM UPS UNIT. PROVIDE AND INSTALL
NEW RACK MOUNTED 1500VA UPS UNIT. PROVIDE AND INSTALL ALL
CONDUIT, WIRE, AND HARDWARE AS REQUIRED.
PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK
RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS
UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND
BREAKERS AS REQUIRED.
1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.
INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND
STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS
INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED
GENERAL ELECTRICAL NOTES
E-512
JFS
HOUSING UNIT 6/7
N ELECTRICAL - HOUSING UNIT 6/7 FLOOR PLAN - POWER
SCALE: 1/8" = 1'-0"
0 1 5 10 20
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
CAMERA JUNCTION BOX INSTALLATION DETAIL
SCALE: N.T.S.3
#10 AWG
#10 AWG
#10 AWG
#10 AWG
ETHERNET SWITCH
CABINET
LIGHTING ARRESTORS
ELECTRICAL EQUIPMENT
TYPICAL FOR
EACH PIECE OF
EQUIPMENT
CONNECT TO GROUND BAR
#10 AWG
TELECOMMUNICATIONS
GROUND BAR
GROUND BAR TYPICAL
TYPICAL CRIMP LUG CONNECTIVITY
1. ALL GROUNDING CONNECTIONS SHALL BE ROUTED TO CLOSEST
GROUND BAR.
2. GROUND BAR WILL BE PROVIDED WITH THE CABINET AND WILL BE
CONNECTED TO THE EARTH, ELECTRICAL GROUNDING SYSTEM,
AND POLE.
3. ALL BONDING CONNECTIONS SHALL BE MAKE WITH TWO HOLE
CRIMP LUGS ONLY AT THE GROUND BAR.
4. FROND CONNECTIONS SHALL BE MAKE WITH A MINIMUM OF #10
AWG CABLE.
5. ALL GROUND WIRES SHALL HAVE GREEN INSULATION.
GROUNDING NOTES
COMMUNICATIONS GROUNDING DETAIL
SCALE: N.T.S.6
WALL FIELD BUILD-OUT FOR CAMERAS ON POLES FED FROM BUILDINGS DETAIL
SCALE: N.T.S.4
BUILDING MOUNTED CAMERA SURGE PROTECTION DETAIL
SCALE: N.T.S.2
NETWORK CABINET DETAIL - TYPICAL FOR PERIMETER CABINETS
SCALE: N.T.S.1
CAMERA MOUNTED ON POLE DETAIL
SCALE: N.T.S.5
TYPICAL CONDUIT MOUNTING DETAIL
SCALE: N.T.S.
SQUARE POLE1" RGS CONDUIT
SQUARE POLE
STAINLESS
STEEL PIPE
STRAP.
3 REQUIRED,
MIN.
STAINLESS
STEEL
MOUNTING
BRACKET
ROUND STEEL
OR WOOD
POLE
1" RGS CONDUIT
ROUND POLE
STAINLESS
STEEL PIPE
STRAP.
3 REQUIRED,
MIN.
STAINLESS
STEEL
MOUNTING
BRACKET
POLE1" RGS CONDUIT
ANGLE POLE
STAINLESS
STEEL PIPE
STRAP.
3 REQUIRED,
MIN.
STAINLESS
STEEL
MOUNTING
BRACKET
71500VA WALL BRACKET DETAIL
SCALE: N.T.S.8
1500VA UPS UNIT
TOP BRACKET
BOTTOM BRACKET
SCREW SECURING BRACKET TO WALL
(TYPICAL) REPEAT ON BOTTOM BRACKET
SCREW SECURING BRACKET TO UPS UNIT
(TYPICAL) REPEAT ON BOTTOM BRACKET
PATCH PANEL
DATA SWITCH
EXTERIOR BUILDING WALL
RACK MOUNTED SURGE
PROTECTOR DITEK MODEL
NUMBER DTK-RM12NETS
TO GROUND BUS TYP.
#10 GROUND
WIRE
NEW 1" RIGID CONDUIT
TO CAMERA
EXISTING 1" CONDUIT TO
CABINET
NEW SURGE
SUPPRESSOR
RAYCAP NJ2010B
NEW 8"W X 8"H X 4"D
ENCLOSURE, NEMA 3R, HINGED
JUNCTION BOX HOFFMAN
A10R86HCR. IF 3 OR MORE
CAMERAS ON POLE, INCREASE
HEIGHT TO 16".
PROVIDE WITH PAD
LOCKABLE HASP
STAINLESS
STEEL PIPE
STRAP, TYP.
STEEL
CHANNEL,
UNISTRUT OR
EQ.
EXISTING #6 COPPER
GROUND WIRE IN 3/4" PVC
CONDUIT TO 3/4" X 8' GROUND
ROD AND POLE.
POLE
SIDE VIEWFRONT VIEW
NEW 1"x3"x1/4" TK.
COPPER GROUND BAR.
TSS
NEW CAT-6 CABLE TO
CAMERA AND GROUND.
GROUND CABLE TO
CAMERA GROUND LUG.
EXISTING
CAT-6 CABLE
EXISTING GROUND
WIRE IN POLE TO
EXISTING GROUND
ROD
NEW #10 GND
WIRE
EXISTING POWER
STRIP FED FROM
UPS
REMOVE EXISTING AND REPLACE WITH NEW
SURGE SUPPRESSORS, LIGHTING ARRESTORS
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX
EXISTING TYPICAL
COMMUNICATION CONDUITS TO
LIGHT POLES AND OTHER
CABINETS
EXISTING GROUND BAR
NEW CAT 6 CABLES TO
CAMERAS
NEW CAT 6 CABLES TO
CAMERAS
EXISTING 2'X2'
FIREPROOF PLYWOOD
WALL FIELD
NEW CAT 6 CABLES TO
CAMERAS
CAT-6 PATCH CABLES
ADD D-RINGS AS REQUIRED
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX
EXISTING MODULAR JACKS
IN SURFACE MOUNT BOX
EXISTING MODULAR JACKS
IN SURFACE MOUNT BOX
EXISTING CONDUIT FROM
UPS
NEW #10 WIRE, (1)
PER SURGE
PROTECTION DEVICE.
CAT-6 PATCH CABLES
EXISTING POE INJECTORS
EXISTING CAT 6 CABLES TO
CAMERAS.
NEW CAT 6 CABLES TO
CAMERAS.
EXISTING CAT 6 CABLES TO
CAMERAS.
NEW CAT 6 CABLES TO
CAMERAS.
NEW #10 GROUND WIRE TO
CAMERAS
EXISTING
GROUND
WIRE TO
GROUND ROD
GRADE
HANDHOLE
FIXED CAMERA
MOUNTING HEIGHT
EXISTING
1" TYPE C
JUNCTION BOX
EXISTING POLE
PTZ CAMERA
MOUNTING HEIGHT
NEW 3/4" RIGID CONDUIT
EXISTING BACK BOX
16' AFG MINIMUM
OR 2' ABOVE
RAZORWIRE
MINIMUM
22' AFG MINIMUM
OR 2' ABOVE
RAZORWIRE
MINIMUM
46-52" AFG
EXISTING GROUND WIRE
EXISTING GROUND ROD
NEW JUNCTION BOX.
REFER TO SHEET
E-801 DETAIL 3
EXISTING LOW VOLTAGE CONDUIT
TO CABINET
K
EXISTING MOUNTING POLE
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX. TERMINATE
ALL NEW CABLES HERE FOR
TESTING.
EXISTING MODULAR JACKS
IN SURFACE MOUNT BOX.
EXISTING
MOUNTING
POLE
NEW SURGE PROTECTION
DEVICES.
EXISTING POE INJECTORS
EXISTING POWER
SUPPLY FOR
ETHERNET
SWITCH- TO
REMAIN
EXISTING
ETHERNET
SWITCH
FUTURE
SWITCH
EXISTING POWER
SUPPLY FOR
ETHERNET
SWITCH- FUTURE
EXISTING FIBER OPTIC
PATCH PANEL
RESERVED FOR ELECTRICAL
EXISTING PLUG STRIP
TO POWER SOURCE
NEW #10 GROUND WIRE
EXISTING TYPICAL
COMMUNICATIONS
CONDUITS WITH
NEW #10 GND TO
LIGHT POLES AND
OTHER CABINETS.
EXISTING GROUND BAR
REFER TO SHEET E-800
DETAIL 6 FOR TERMINATION
INFORMATION. ADD
ADDITIONAL GROUND BARS
AS NEEDED FOR NEW #10
GND
NEW #10 GROUND
WIRE
EXISTING
GROUND
WIRE TO
GROUND ROD
LIGHTING
CONTROLLER
LIGHTING
CONTROLLER
POWER
DISCONNECT AND REMOVE LIGHTING CONTROLLER AND
LIGHTING CONTROLLER POWER DEVICES.
DISCONNECT AND REMOVE CAT6 CABLE FROM EXISTING
ETHERNET SWITCH TO EXISTING LIGHTING CONTROL
SERVER LOCATED IN ADMINISTRATION BUILDING.
DISCONNECT AND REMOVE CAT6 CABLE FROM ETHERNET
SWITCH TO LIGHTING CONTROLLER.
DISCONNECT AND REMOVE LIGHTING CONTROL CABLE AND
CAMERA CONTACT CLOSURE CABLE
DEMOLITION NOTES
1 1
EXISTING AUXILIARY
GUTTER
EXISTING
CONDUIT AND
WIRE TO POLES
FOR LIGHT
FIXTURE POWER
EXISTING
CONDUIT AND
WIRE TO POLES
FOR LIGHT
FIXTURE POWER
E-800
DRK
JFS
ELECTRICAL DETAILS
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
SALLY PORT CAMERA DRIVE DETAIL
SCALE: N.T.S.4
SALLY PORT
NEW CAMERA MOUNTED
CENTER OF GATE
NEW POLE TRUSS
NEW CAMERA POLE
SALLY PORT DRIVE
GRADE
NEW 1" LOW
VOLTAGE CONDUIT
FROM LOW VOLTAGE
HAND HOLE
3'
PROVIDE #4 REBAR CAGES
IN EACH FOUNDATION
6'-6"
PROVIDE 6'-6" DEEP 24" DIAM. CONCRETE
BASE POURED IN PLACE OR PRECAST
CONCRETE FOUNDATION
NEW EARTH
HAND HOLE
SALLY PORT OVERHEAD CAMERA DETAIL
SCALE: N.T.S.3
FACTORY INSTALLED
VIBRATION DAMPENER
NEW 360 DEGREE
CAMERA CENTERED
ON SALLY PORT DRIVE
NEW POLE
2-3/8" BOX
CONNECTOR
NEW CAMERA
BACK BOX
NEW JUNCTION BOX. NEW
SURGE PROTECTION DEVICE
LOCATED INSIDE.
18'
14'
NEW CAMERA POLE BASE
BUILDING 200
PERIMETER
FENCE
SECURED
AREA
UNSECURED
AREA
SCALE: N.T.S.
SURGE PROTECTION
DEVICE
#10 GROUND WIRE IN 1"
CONDUIT FROM POLE TO
CABINET.
FIXED OR PTZ
CAMERA ON POLE
GROUND AT CABINET
TYPICAL PERIMETER CAMERA CABINET TO POLE GROUNDING DIAGRAM
SCALE: N.T.S.7
LOW VOLTAGE
SURGE PROTECTION
DEVICE.
#10 GROUND
WIRE IN 3/4"
CONDUIT
TSS
#6 GROUND
WIRE IN 3/4" CND
SURGE
PROTECTION
DEVICE.
NEW 3/4" X 8'
GROUND ROD
#10 GROUND
WIRE
1"X3"X1/4'" COPPER
GROUND BAR
#12 GROUND WIRE
GROUND BAR
NEMA 3R,
JUNCTION BOX
#6 GROUND
WIRE IN 3/4" CND
EXISTING
3/4" X 8'
GROUND ROD
CAMERA BACK
BOX
#10 GROUND WIRE IN 1"
CONDUIT TO LIGHT POLES
AND OTHER CABINETS
#10 GROUND
WIRE
#10 GROUND
WIRE
#10 GROUND
WIRE
TYPICAL PERIMETER CAMERA CONNECTIVITY DIAGRAM - EXISTING POLE1
CAB-XXX
ETHERNET
SWITCH
POE
INJECTOR
SURGE
PROTECTOR
SURGE
PROTECTOR
EXISTING PERIMETER CABINET. REFER TO
SHEET E-800 DETAIL 1 FOR CABINET
CONNECTIVITY
CONNECT TO GROUND
BAR #10 AWG TYP.
CONDUIT WITH CAT-6 CABLE
AND NEW #10 GROUND
NEW JUNCTION BOX. NEW SURGE
PROTECTION DEVICE
RAYCAP NJ2010B LOCATED INSIDE.
REFER TO SHEET E-800 DETAIL 3
FIXED CAMERA
SEE SHEET E-00 DETAIL 5 FOR HEIGHTS
(1) 3/4" RIGID
CONDUIT
ADD ADDITIONAL
GROUND BARS AS
REQUIRED.
(1) 3/4" RIGID
CONDUIT
NEW CAT-6 PATCH
CABLE & NEW
GROUND CABLE IN
CONDUIT
NEW CAT-6 PATCH
CABLE & NEW
GROUND CABLE IN
CONDUIT
PTZ CAMERA
SEE SHEET E-00 DETAIL 5 FOR HEIGHTS
NEW JUNCTION BOX. NEW SURGE
PROTECTION DEVICE
RAYCAP NJ2010B LOCATED INSIDE.
REFER TO SHEET E-800 DETAIL 3
GROUND
BUS
EXISTING GROUND
WIRE TO ROD
#6 GROUND TO
NEW GROUND ROD
#6 GROUND TO
NEW GROUND ROD
E-801
DRK
JFS
ELECTRICAL DETAILS
C om m te ch
D es ig n
472/23198.JGH
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472ICFMaintproj consultant job no.
1065_24B sheet title
Y23464
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY
UPGRADES
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
M a tr ix
5/14/26 ISSUE FOR BID
NEW CAMERA POLE BASE
UNSECURED AREA
CAMERA EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO. DROP CEILING HARD
CEILING/WALL
BUILDING
EXTERIOR
BUILDING
EXTERIOR
CORNER
POLE MOUNT
SECURITY EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
ABBREVIATIONS
ABBREV. DESCRIPTION ABBREV. DESCRIPTION
PC-XXX
LT-XXX
NETWORK EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
COMMUNICATION CABLE SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
ACCESS CONTROL (PACS) EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
SECURITY SYMBOL LEGEND
SYMBOL DESCRIPTION
ATTIC STOCK EQUIPMENT
MARK DESCRIPTION
COMMUNICATION EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
AUDIO/VIDEO EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
TC101
LEGENDS, DETAILS
AND SCHEDULES
C om m te ch
D es ig n
B
EL
D
IN
G R
O
AD
N E.
, S U
IT
E
B R
O C
KF
O
R…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .