This is Addendum 01 to the Request for Proposal (RFP) for the Ionia Correctional Facility Video Management System (VMS) Upgrade issued by the State of Michigan. The addendum modifies the original solicitation 472/23198.JGH by clarifying project requirements and specifications for the VMS upgrade at the Ionia facility. The document addresses technical specifications, system requirements, and vendor qualifications necessary to support the facility's video surveillance infrastructure modernization. Key modifications include updates to system compatibility requirements, equipment specifications, and installation timelines. Vendors responding to this solicitation must account for all addendum provisions in their bids, as the addendum becomes an integral part of the contract documents and supersedes any conflicting language in the original RFP.

The addendum establishes binding requirements that all bidders must incorporate into their proposals and pricing submissions. Failure to acknowledge receipt and acceptance of Addendum 01 may result in bid rejection. The modifications outlined in the addendum directly impact both technical approach and cost proposals, requiring bidders to carefully review all changes and their implications for system design, implementation, and ongoing maintenance. All bid submissions must reference compliance with the addendum specifications and include any necessary cost adjustments resulting from the revised requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DTMB-0414 (Rev 12/17)

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

State Facilities Administration Design and Construction Division

CONSTRUCTION BID ADDENDUM NO. 01

This form identifies an Addendum to Bidding Documents, and incorporates interpretations or clarifications, modifications, acceptance of proposed “or equal” materials, and other information into the Bidding Documents. Addenda will be numbered by the Professional and distributed through www.michigan.gov/SIGMAVSS as an attachment.

TO:

ALL BIDDERS

DATE ISSUED

6/4/2026

PROJECT NAME

Ionia Correctional Facility – Video Management System Upgrade

FILE NUMBER

472/23198.JGH

PROFESSIONAL

Commtech Design, Inc.

PROJECT DIRECTOR

Jared Gavin-Helfrich

BID OPENING DATE:

6/10/2026

ADDENDUM ITEMS: (attach additional sheets and drawings if required) Attachments;

1. Meeting Attendance record, Pre-Bid sign-in sheets.

2. NEW Bid Schedule

3. Reissued Drawings (See Below)

Specifications

1. New Bid schedule

Drawings reissued

1. TC101, TC106, TC110 thru TC118, TC119, TC120, TC122 - Re-issued

2. TC301, TC302A, TC302B, TC318 - Re-Issued

3. E-200, E-501, E-506 -Re-Issued

Questions:

1. Support Services comm room S2 shown on TC108 states “No camera cables to this comm room.” TC302B states “cables on this side of line shall route to Comm S2.” The one line does not show a new switch for S2.

Please advise.

Answer. All cables shall route to Comm S1 as noted on TC108. The note shown on TC302A & B was not updated as part of an old project. See TC302A & B.

2. One line general security notes 4 & 5 on TC110 states that all drop ceiling cameras shall be recessed mount.

There is no part # provided for drop ceiling mounts for CC or CE type cameras. Please advise

Answer. All drop ceiling mounts shall be ‘surface mount’. TC110 thru TC118

3. Perimeter #10 ground wire. Drawing E800 shows "New #10 Ground" in details 1 & 3. For clarity, are we to install a new #10 ground wire from every pole to each cabinet?

Answer. Yes, a #10 Ground wire shall be installed from each pole to the nearest cabinet.

4. Lighting control. On E501 Keynote 7, we are directed to demo the horner lighting control. We are to provide a new lighting control override switch and connect to existing Ultralink system. Please provide a more specific detail with part #'s and a one line - assume some sort of contactor, photocell setup would be required. No info as to the lighting circuit's origin, circuit size, etc is provided. Is there to be a control center manual override button? More info required to quote this work.

Answer. See re-issued sheets E-200, E-501, and E-506.

5. Sheet TC301 shows a new Intercom Base Station is needed on the 2nd floor of the Admin Building 100. This base station is not shown on detail 2 of sheet TC120. Is it required?

Answer. The base station on the 2nd floor of the Admin Building shall not be provided as part of this project. See TC301

6. Door Hardware Spec 08 7100 shows new panic bars with request to exit sensors will be installed at Doors 101; 104 & 204. Sheet TC301 and TC120 do not show the RX symbol, will these request to exit sensors need to be connected to the access control system?

Answer. See TC301. We have updated doors with RX where required. We do not see door 204 and are assuming this is referring to door 201.

Clarifications:

7. TC-111: ICF-1264 is shown as a surface mount but labeled as pendant mount. Which is correct?

Answer. Camera ICF-1264 shall be pendant. See TC111

8. TC-111: ICF-1266 is shown as a pendant mount but labeled as hard ceiling surface mount. Which is correct?

Answer. Camera ICF-1266 shall be surface mount. See TC111

9. Drawing TC301 references a base station (BS) on the second floor, but the one-line drawing TC120 does not show it. Will this exist?

Answer. The base station on the 2nd floor of the Admin Building shall not be needed. See TC301

10. 283500 1.03 C 2 says multisheath cable shall be White in color or multicolor cables. Is pink sufficient so it matches the cat6 color scheme?

Answer. Yes. If you can find a Pink Multi-sheath cable for access control, Plenum rated we would approve and allow.

11. TC120 & TC301 show a motion request to exit only on door 202. Please confirm this is the only door that should be receiving one.

Answer. The following doors shall receive a request to exit in lock: 101, 103.1, 103.2, 104 and 201.

See TC301 and TC120.

12. TC110 shows "XM" for the Deputy Conference Room 1-139 PC but offers a description of "pull out corner mount". The Warden's Conference room 1-179 shares this description and is labelled XN. Please confirm if this should be XM or XN.

Answer. Each mount is shown correctly ‘XM’ is a 55” LCD mount. ‘XN’ is a 65” LCD mount with both mounts articulating. The ‘XN’ mount will be installed close to the ‘corner’ in Conf Rm 1-179.

13. TC110 shows the new cameras goes to a new patch panel that is being patched to switch type NB. This is a fiber switch. This patch panel appears to be located in Comm Room A3. Should these new connections be routed to A2, or should a copper POE NC style switch also be installed in Comm Room A3?

Answer. Good note. See TC110 updated to show the CAT-6 connections being routed to the NC style copper POE Switch

14. TC110 shows 9 PCs with both the SD and SL label. Which one is correct?

Answer. Each PC shall have SD & SK. See TC110 thru 112.

15. TC110 shows Symphony PC in a rack. TC122 shows it on a shelf under the desk or on the wall. Which is the desired mounting solution?

Answer. The Server shall be rack mounted in the Admin comm room. The PC shall be mounted on the wall in Admin Central Control.

16. TC318 shows a new conduit going from Housing Unit 6/7 to the Weight Pit. It also shows a line from a similar spot on the building going to the Education building. What is this extra line signifying? There is no mention of it on E-200.

Answer. The extra line is an existing conduit from HU 6/7 to the education building. There is no associated work with this conduit for this project. See updated TC318

17. Support services building shows two IDFs, but only one is mentioned in the one-line drawings. Does this second IDF exist and if so, can we get updated drawings reflecting the cameras and switch count that needs to be there?

Answer. Yes, there are (2) existing Comm Rooms S1 & S2 with camera cables terminating in S1 only.

18. Education shows two IDFs, but only one is mentioned in the one-line. Can we get confirmation that all cameras and workstations are going to E1 and E2 is not used for this project?

Answer. Yes, there are (2) existing Comm Rooms E1 & E2 with all camera cables terminating in E1 only.

19. TC301 shows a cooling cabinet in the EM Room. TC110 says this is an existing cabinet. Please confirm that this is existing and not something that needs to be provided.

Answer. The cooling cabinet in the EM Room exists and will not need to be provided as part of this contract. This is just a technology cabinet that houses the PC’s

20. Most of the Genetec workstations show SH for the keyboard and mouse, but SH is a KVM. Should this be SG or SJ?

Answer. Use SG for wireless keyboard & mouse. See TC110 thru 112.

21. TC112 shows YO for the privacy screen, but this is not defined anywhere. XQ looks like it may be what this is supposed to be, please confirm.

Answer. Use YH which is a 55” monitor privacy screen. See TC101 & TC112.

22. TC110 shows SF for the ICF-BUBBLE, but this is shown to be a laptop. Which is this supposed to be?

Answer. Use SE which is a Genetec mini monitoring PC. See TC110.

23. TC101 shows a single gang card reader as Signo 40-PIV. 283500 2.13 A 12 shows it as 40NKS-00-000000, which is not a Signo PIV part. Please confirm the reader.

Answer. The specifications are correct. We changed the note on TC101 to read “SEE SPECS”

24. E-501: Three of the four data racks shown get power fed from both the UPS-A panel and the RP-A panel. The topmost one has both feeds from the UPS-A panel. Is this correct?

Answer. One of the feeds shall be from RP-A.

25. TC-112 shows camera ICF-1342 having a wall arm mount on an interior wall. There are not accessories mentioned for this scenario. Should this be using the same as the "building exterior"?

Answer. Yes, camera ICF-1342 shall use a building exterior mount. See TC112.

26. The existing Starnet is a completely independent Cisco network. They only show 10 ultralinks, but there are

15 out there. 4 of these will have no connection back to a place with security network switches.

Answer. Yes, there are a total of (15) Ultralink locations. See updated site plan and connectivity diagram. TC122 & TC318. Assume each has a network connection that is able to be connected to the new Ethernet Network being provided as part of this project.

Answer. Transition these Ultralinks to the new Camera network as part of this project.

27. There are existing camera switches in the gun towers that are not referenced. The fiber feeding these switches is likely the same fiber feeding the Starnet cisco switches...or maybe they're the same thing?

Answer. Bid as per design documents.

28. Conference room TC106 CP references a 3 rack unit custom plate in the A/V Cabinet. There is also a note to mount the PC enclosure on the wall next to LCD. Please advise which PC enclosure to provide.

Answer. See updated TC106. Change reference to PC enclosure to mount plates at LCD location on wall. Fish wall. See updated detail “CP” to remove reference to “3-Rack unit tall”

29. Who is responsible for providing locking hardware for the access control doors?

Answer. All work in the contract Specifications and Drawings is the responsibility of the contractor.

This project will have a single contractor who is responsible for the entire project. That contractor may have subcontractors. The State of Michigan will recognize one contractor to hold the contract and be responsible for all aspects of the work. See Door hardware Specification 087100

30. Will an updated Detail 4/TC119 be provided with correct call out icons?

Answer. See TC119 re-issued. Reference list of equipment on TC101

31. Will an updated inspector PC location detail be provided with correct icons?

Answer. Yes an updated Inspector PC location is provided. See TC110.

32. Please confirm the security var is providing new 24 port patch panels and new core ethernet switches.

Answer. The contractor hired as part of this project shall provide and install all Patch panels for new data cables being installed.

33. Confirm symbol "SH" is for KVM switch and "SG" is for wireless mouse and keyboard. TC110 has mouse and keyboard labeled as "SH".

Answer. Use SG for wireless keyboard & mouse. See TC110 thru 112.

34. Will and updated detail be provided for the ICF-Bubble PC2 Mini New with correct icons?

Answer. Yes an updated ICF-Bubble PC2 Mini New detail is provided. See TC110.

35. Confirm the symbol for the "Equipment technician laptop-replace" on TC111 should be SF not SG?

Answer. Use SF for Equipment Technician laptop-replace. See TC111.

36. Please confirm whether security contractor is to furnish all Ethernet switches (core and edge), or if switches will be owner-furnished and/or reused.

Answer. Contractor shall furnish, install and configure all Ethernet switches (core & edge).

37. Please confirm security contractor is responsible for all Genetec VMS, Synergis, and associated licensing

(camera, server, workstation).

Answer. Refer to Specification 283600, Specifically note 2.08

38. Please Confirm whether security contractor is responsible for full network configuration (VLANs, IP addressing, switch programming) or owner IT support will provide.

Answer. Contractor shall furnish, install and configure all Ethernet switches (core & edge).

39. Do any physical doors and or door frames need to be replaced? If so, please identify door locations.

Answer. No, there shall be no doors or door frames to be replaced.

40. Please confirm the correct part number and alternative solution regarding LG: 22MD4KA-B. The part is discontinued.

Answer. Where this monitor is specified, provide the item XB NEC 22” monitor

41. Can you provide Input/Output Configuration for Symphony?

Answer. The UCM file is not available prior to issuance of this bulletin. Assume 8 points are being monitored on each Ultralink for bid scope purposes and field investigation purposes. The UCM file will be available to the chosen contractor for this project. See TC122

42. Can you provide the current config files for the existing SenStar system. Symphony?

Answer. The UCM file is not available prior to issuance of this bulletin. Assume 8 points are being monitored on each Ultralink for bid scope purposes and field investigation purposes. The UCM file will be available to the chosen contractor for this project.

43. There isn’t an Access Control portion to the bid schedule. Could you please add?

Answer. This has been added to the Bid Schedule document. See new Bid Schedule issued with this addendum

44. Does the new (additional) Aruba core switch need to provide copper access ports, or is an SFP+ interface-only switch acceptable? The network diagrams show cameras connecting directly to the switch, which would suggest that copper ports are required. However, the specifications appear to call for an SFP+ switch for the additional Aruba core switch based on the diagram. Can you have them clarify the expected interface requirements for the new core switch?

Answer. When using the “additional” Aruba core it shall be SFP+ ports. The difference is that the Cisco SFP+ switches are 48 port and Aruba are 24. The owner wants to have a minimum of 72 SFP+ ports available. The “additional” switch if Aruba is provided shall be configured and ready to be used in case of loss of a different Core Switch.

45. Are we to assume any saw cutting of concrete will come out of the hydrovac allowance or cover it in the contractor scope?

Answer. The Hydrovac Allowance is for Hydrovac work only. Include any other work in the Contractor Scope

46. On sheet E-200 note 7 shows a 1” conduit running across a concrete slab, it doesn’t mention anything about how to get it across the slab. Is the contractor responsible for saw cut, removal, and infill of the concrete to get this conduit across the area shown?

Answer. All site conduit installation shall be directionally bored. See keynote 6.

ACKNOWLEDGEMENT: This Addendum must be acknowledged by the Bidder in the space provided in the Bid Summary and Bid Form. Failing to acknowledge Addenda may be cause for the Bid to be rejected. Addenda will become part of the Contract Documents.

PROFESSIONAL: Bret Emerson, Commtech Design DATE: 6/4/2026

APPROVED BY:

PROJECT DIRECTOR: DATE: Click to enter date

MICHSPEC DTMB 00300 − 4

ARTICLE 6 BID SCHEDULE – ADD 01

6.1 Base Bid Schedule - The Bidder will complete the Work and accept in full payment, for the Work items listed, the following unit prices and/or Bid Prices, as applicable:

Base Bid Item No.

Bid Quantity

Description

Unit Price

Item Bid Price

1 1 Cameras & Cabling Equipment

2 1 Camera and Cabling labor

3 1 Camera Licenses

4 1 Servers and Storage Equipment

5 1 Servers and Storage Labor

6 1 Network Switches Equipment

7 1 Network Switches Labor

8 1 Genetec Integrator Scope (GIS) Equipment

9 1 Genetec Integrator Scope (GIS) Labor

10 1 General Conditions

11 1 Electrical equipment including UPS and lighting protection

12 1 Electrical labor including UPS and lighting protection

13 1 Audio/Video equipment

14 1 Audio/Video labor

15 1 Symphony monitoring system Equipment

16 1 Symphony monitoring system Labor

17 1 Access Control Equipment

18 1 Access Control Labor

19 1 Mobilization

20 1 Bonds and Warranty

21 1 2% Code Approval

22 1 2% Warranty

23 1 2% As-Builts

CONTINGENCY ALLOWANCE AMOUNT $75,000.00 $75,000.00

HYDROVAC ALLOWANCE $30,000.00 $30,000.00

TOTAL (This amount should equal the Base Bid amount on the Bid Summary Form) $

Base Bid (Sum of Bid Prices for all Base Bid Items):

________________________________________________________________ Dollars and No/Cents $__________________________ (use words) (in figures)

Name of the Bidder _________________________________________ File No. _______________

Date _________________________

SIGMA VENDOR NUMBER _________________________________

Telephone No. _______________________

C

C

C C

C

C

C

C

C

C

C

C C

C

C

C

C

C C

C C

C

C

C

C

PL-017

PL-018

PL-019

PL-020

PL-021

PL-022

PL-023

PL-024

PL-025

PL-026

PL-027

PL-028

PL-029

PL-030

PL-031

PL-032

PL-033

PL-034

PL-035

PL-036PL-037

PL-038PL-039

PL-039B

PL-001

PL-002

PL-003

PL-004

PL-005

PL-006

PL-007

PL-008

PL-009

PL-010

PL-011

PL-012

PL-013

PL-014 PL-015

PL-016

PL-001B

PL-039A

PL-016A

PL-008A

PL-027A

PL-033A

PL-001A

C

C

C

C

C

C C

C

C

C C

C

C

C C C

C

C

C

C

C

C

C

C

C

C

C

C

C

C C

C

CC

C

C

C

C

C

C

C

C

C

C

C

C C

C P

2 2

1 1

(1) 1" CND

(1) 1" CND

(1) 1" CND

C2

C2

C

C 2

C 2

C

C

C

C

C

C 2

C 2C

C C

(1) 1" CND 6

2" CND

2" CND

2" CND

2" CND

2" CND

2" CND

2" CND

2" CND

ELECTRICAL KEY NOTES

PROVIDE AND INSTALL NEW SURGE PROTECTION DEVICES

AND JUNCTION BOX FOR CAMERAS ON POLE. ALL POLES ARE

EXISTING TO REMAIN UNLESS OTHERWISE SPECIFIED. REFER

TO SHEET E-800 DETAIL 3.

PROVIDE AND INSTALL NEW SURGE PROTECTION DEVICES IN

COMMUNICATIONS ROOM FOR CAMERAS ON BUILDING.

REFER TO SHEET E-800 DETAIL 2.

REMOVE EXISTING SURGE PROTECTION DEVICES AND

HORNER LIGHTING CONTROLS. PROVIDE AND INSTALL NEW

SURGE PROTECTION DEVICES IN PERIMETER CABINET

(RAYCAP G29-00-394-OTL-PROTEC-T1-40 AND RAYCAP

NJ2010B). REFER TO SHEET E-800 DETAIL 1. REMOVE ALL

HARDWARE AND EXPOSED WIRING FROM THE CABINET AND

MAKE SAFE.

PROVIDE AND INSTALL NEW POLE AND BASE FOR NEW 360

DEGREE SALLY PORT DRIVE CAMERA. REFER TO SHEET E-801

DETAILS 3&4 AND POLE SCHEDULE ON SHEET E-100.

PROVIDE AND INSTALL NEW NEMA 3R RATED JUNCTION BOX

ON THE EXTERIOR WALL OF BUILDING. LOCATE THE

JUNCTION BOX OUTSIDE THE COMMUNICATIONS ROOM.

DIRECTIONALLY BORE CONDUIT TO JUNCTION BOX ON

EXTERIOR WALL OF BUILDING AS SHOWN. REFER TO LOW

VOLTAGE DRAWINGS FOR CABLE TYPE AND QUANTITY.

PROVIDE AND INSTALL NEW NEMA 3R RATED JUNCTION BOX

ABOVE CAGE FOR NEW CAMERAS. REFER TO LOW VOLTAGE

DRAWINGS FOR DETAILS.

PROVIDE AND INSTALL NEW DIRECTIONALLY BORED AND

HYDRO-EXCAVATED CONDUIT AS INDICATED. (3) #8, (1) #8

GND, 2" CND. CONNECT TO EXISTING CABINET CONTROL

TRANSFORMER. ALTERNATE PHASES FOR EACH CABINET

CONNECTION.

REMOVE EXISTING LIGHT POLE TO CABINET CONNECTION.

REMOVE ASSOCIATED CONDUIT AND WIRE.

1. PROVIDE AND INSTALL NEW DIRECTIONALLY BORED

CONDUITS AND WIRE.

2. CUT OVER ALL CONNECTIONS. COORDINATE ALL SHUT

DOWNS WITH FACILITY.

3. REMOVE EXISTING POLE TO CABINET CONNECTIONS.

REMOVE ASSOCIATED CONDUIT AND WIRE.

SEQUENCE OF INSTALLATION

CABINET

EXIST.

CND AND

WIRE TO

REMAIN

EX. CABINET

CONNECTION TO BE

REMOVED

EX.

LIGHTING

CIRCUIT

NEW UPS

CONNECTION

(3) #8

(1) #8 GND

2" CND

E-200

JJD

JFS

SITE PLAN

POWER

N ELECTRICAL - SITE PLAN - POWER

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a t r ix

M a t r ix

5/14/26 ISSUE FOR BID

6/03/26ADDENDUM 01

SCALE: 1" = 60'-0"

400 10 20 80 150

6/04/26

DR

DR

EX PANEL "UPS-A"

120/208V-3Ø, 100A DR

EX 30KVA UPS

TEX 30KVA XFMR

TL

TL

TL

TL

TL

TL

EX PANEL "MPB"

480V-3Ø, 600A

EX PANEL "UPS"

480V-3Ø, 30A

TEX

EX PANEL "L-RPX"

120/208V-3Ø, 100A

EX PANEL "RPX"

120/208V-3Ø, 100A

EX PANEL "LP-XA"

277V-3Ø, 100A

REPLACED PANEL "RP-A"

120/208V-3Ø, 100A

EX PANEL "LP-ZA"

277V-3Ø, 100A

EX PANEL "LP-BB"

277V-3Ø, 100A

EX PANEL "EMPB"

480V-3Ø, 100A

RP-A-50,52,54

UPS-A-25,27,29

UPS-A-31

UPS-A-33

RP-A-43

UPS-A-35

RP-A-45

RP-A-47

DR

TL

TL

NEW LIGHTING

CONTACTOR

EXISTING

SENSTAR

CONTROL CENTER

MANUAL OVERIDE

BUTTON

STARTNET

2 MODULE

NEW LIGHTING 6

POLE CONTACTOR

CONTACTOR CIRCUITS

(SITE LIGHTING)

PANEL

EXISTING

UPS

480/277 V

3Ø, 4W 30A C

PANEL

EXISTING

EMPB

480/277 V

3Ø, 4W 100A

NEW SITE CABINET

CONNECTION

(3) #8

(1) #8 GND

2" CND

EX 30KVA UPS

480/277V-3Ø

30A/3P

3PH 4W

NEMA 1

FUSED

30A FUSES

(3) #8

(1) #8 GND

2" CNDEX

(4) #10

(1) #10 GND

3/4" CND

ELECTRICAL KEY NOTES

PROVIDE AND INSTALL (2) NEW BLUE 30A L21-30R TWISTLOCK

RECEPTACLE FROM UPS POWER. CONNECT TO SEPARATE

VERTICAL POWER STRIPS ON BACK OF RACK. PROVIDE AND

INSTALL ALL CONDUIT WIRE AND HARDWARE AS REQUIRED.

REFER TO SHEET E-100 DETAIL 1.

PROVIDE AND INSTALL (1) NEW BLUE 20A TWISTLOCK

RECEPTACLE FROM UPS POWER AND (1) NEW RED 20A

TWISTLOCK RECEPTACLE FROM GENERATOR POWER.

CONNECT TO SEPARATE VERTICAL POWER STRIPS ON BACK

OF RACK. PROVIDE AND INSTALL ALL CONDUIT WIRE AND

HARDWARE AS REQUIRED. REFER TO SHEET E-100 DETAIL 2.

PROVIDE AND INSTALL (2) VERTIV I10087 POWER STRIPS ON

THE BACK OF THE RACK. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL (2) VERTIV 38607 POWER STRIPS ON

THE BACK OF THE RACK. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL NEW LINE VOLTAGE SURGE

PROTECTION DEVICE IN PANEL (RAYCAP

RSE-2-277-3Y-A-10-E-F-S).

PROVIDE AND INSTALL NEW LINE VOLTAGE SURGE

PROTECTION DEVICE IN PANEL (RAYCAP

RSE-2-277-3Y-A-5-E-F-S).

DISCONNECT AND REMOVE EXISTING HORNER LIGHTING

CONTROL SERVER. REMOVE ASSOCIATED CONDUIT AND

WIRE.

MODIFY EXISTING SITE LIGHTING CIRCUITS AS INDICATED

FOR REMOVAL OF HORNER CONTROL SYSTEM. PROVIDE

NEW 60A 6P CONTACTOR. CONNECT TO EXISTING BUILDING

ULTRALINK MODULE AND STARNET2 SYSTEM. MODIFY

EXISTING CONDUIT AND WIRE AS REQUIRED.

CONTRACTOR SHALL PROVIDE NEW CONNECTION TO SITE

CABINETS. PROVIDE NEW 30A-3P DISCONNECT. REFER TO

SHEET E-200 FOR MORE INFORMATION.

CONTRACTOR SHALL REFEED EXISTING UPS PANEL FROM

PANEL EMPB AS INDICATED. USE EXISTING 30A-3P SPARE

BREAKER. RE-LABEL UPS PANEL TO "LP-XB".

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-501

JFS

EAST 100 ADMIN - SECOND

FLOOR

N

ELECTRICAL - EAST 100 ADMIN FLOOR PLAN - SECOND

FLOOR - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a t r ix

M a t r ix

5/14/26 ISSUE FOR BID

6/03/26ADDENDUM 01

JJD

RUPS1

EXISTING 30KVA UPS

EX PANEL "LPA"

277/480V-3Ø, 225A

EX PANEL "UPS"

277/480V-3Ø, 60A

EX SUB PANEL

120/208V-3Ø, 100A

EX PANEL "E"

120/208V-3Ø, 30A

EX PANEL "YA"

277/480V-3Ø, 225A

EX PANEL "LPEE"

277/480V-3Ø, 225A

EX SW "M-MDP"

277/480V-3Ø

E-13

EXISTING

SENSTAR

CONTROL CENTER

MANUAL OVERIDE

BUTTON

STARTNET

2 MODULE

NEW LIGHTING 9

POLE CONTACTOR

CONTACTOR CIRCUITS

(SITE LIGHTING)

PANEL

EXISTING

UPS

480/277 V

3Ø, 4W 60A C

3NEW LIGHTING

CONTACTOR1

PANEL

EXISTING

LPEE

480/277 V

3Ø, 4W 225A

NEW SITE CABINET

CONNECTION

(3) #8

(1) #8 GND

2" CND

EX 30KVA UPS

480/277V-3Ø

30A/3P

3PH 4W

NEMA 1

FUSED

30A FUSES

(3) #8

(1) #8 GND

2" CNDEX

(4) #6

(1) #10 GND

1" CND

ELECTRICAL KEY NOTES

REMOVE ANY AND ALL CAMERA SYSTEM UPS UNITS. PROVIDE AND INSTALL

NEW RACK MOUNTED 1500VA UPS UNITS. PROVIDE AND INSTALL ALL

CONDUIT, WIRE, AND HARDWARE AS REQUIRED.

PROVIDE AND INSTALL RED 20A QUAD RECEPTACLE. MOUNT DATA RACK

RECEPTACLES 90"AFF OR ON CABLE LADDER. CONNECT TO 1500VA UPS

UNIT. PROVIDE AND INSTALL ALL CONDUIT, WIRE, HARDWARE, AND

BREAKERS AS REQUIRED.

MODIFY EXISTING SITE LIGHTING CIRCUITS AS INDICATED

FOR REMOVAL OF HORNER CONTROL SYSTEM. PROVIDE

NEW 100A 9P CONTACTOR. CONNECT TO EXISTING BUILDING

ULTRALINK MODULE AND STARNET2 SYSTEM. MODIFY

EXISTING CONDUIT AND WIRE AS REQUIRED.

CONTRACTOR SHALL PROVIDE NEW CONNECTION TO SITE

CABINETS. PROVIDE NEW 30A-3P DISCONNECT. REFER TO

SHEET E-200 FOR MORE INFORMATION.

CONTRACTOR SHALL REPLACE EXISTING 30A SPARE

BREAKER IN PANEL LPEE WITH A 60A-3P. REFEED EXISTING

UPS PANEL FROM PANEL LPEE AS INDICATED. RE-LABEL UPS

PANEL TO "LPEEA".

1. CONTRACTOR MAY REUSE EXISTING CONDUIT AND BOXES.

INSTALLATION OF ALL NEW OR REWORKED CONDUIT, FITTINGS, AND

STRAPS SHALL FOLLOW SPECIFICATIONS LISTED ON SHEET E-100. THIS

INCLUDES ANY EXISTING CONDUIT/BOXES THAT ARE REUSED

GENERAL ELECTRICAL NOTES

E-506

JFS

400 WAREHOUSE BLDG -

FIRST FLOOR

N

ELECTRICAL - 400 WAREHOUSE BLDG FLOOR PLAN -

FIRST FLOOR - POWER

SCALE: 1/8" = 1'-0"

0 1 5 10 20

C om m te ch

D es ig n

472/23198.JGH

file no.

checked by drawn by consultant issue date acctg template.

contract order no.

472ICFMaintproj consultant job no.

1065_24B sheet title

Y23464

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

VIDEO SECURITY

UPGRADES

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O F

M

IC

H

IG

A N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a t r ix

M a t r ix

5/14/26 ISSUE FOR BID

6/03/26ADDENDUM 01

JJD

CAMERA EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO. DROP CEILING HARD

CEILING/WALL

BUILDING

EXTERIOR

BUILDING

EXTERIOR

CORNER

POLE MOUNT

SECURITY EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

ABBREVIATIONS

ABBREV. DESCRIPTION ABBREV. DESCRIPTION

PC-XXX

LT-XXX

NETWORK EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

COMMUNICATION CABLE SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

ACCESS CONTROL (PACS) EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

SECURITY SYMBOL LEGEND

SYMBOL DESCRIPTION

ATTIC STOCK EQUIPMENT

MARK DESCRIPTION

COMMUNICATION EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

AUDIO/VIDEO EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

TC101

LEGENDS, DETAILS

AND SCHEDULES

C om m te ch

D es ig n

B

EL

D

IN

G R

O

AD

N E.

, S U

IT

E

B R

O C

KF

O

R D

, M

IC

H

IG

AN

W W

W .C

O M

M

TE

C H

D

ES

IG

N

.C O

M

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

M a t r ix

M a t r ix

AutoCAD SHX Text

CA

AutoCAD SHX Text

EXTERIOR (OR INTERIOR) 4K. POLE OR BUILDING MOUNTED, REMOTE AIMABLE.

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

XNV-9083RZ

AutoCAD SHX Text

USE T-BAR ABOVE CEILING

AutoCAD SHX Text

NOT REQUIRED. CAM HAS CONDUIT CUTOUT

AutoCAD SHX Text

SBP-300WMW1-ARM SBP-180HMW1-CAP SBP-300NBW-BOX

AutoCAD SHX Text

SBP-300WMW1-ARM SBP-180HMW1-CAP SBP-300NBW-BOX SBP-300KMW1-MOUNT

AutoCAD SHX Text

SBP-300WMW1-ARMSBP-180HMW1-CAP SBP-300PMW2-POLE SBP-300NBW-BOX SBP-150S-STRAPS

AutoCAD SHX Text

EXTERIOR PTZ CAMERA. POLE OR BUILDING MOUNTED. 2-MEGAPIXEL, 40X ZOOM MINIMUM

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

XNP-C6403R

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

SBP-300WMW1-ARM SBP-156HMW-CAP SBP-300NBW-BOX

AutoCAD SHX Text

SBP-300WMW1-ARM SBP-156HMW-CAP SBP-300NBW-BOX SBP-300KMW1-MOUNT

AutoCAD SHX Text

SBP-300WMW1-ARMSBP-156HMW-CAP SBP-300PMW2-POLE SBP-300NBW-BOX SBP-150S-STRAPS

AutoCAD SHX Text INDOOR AND OUTDOOR 360 FISHEYE. SINGLE IMAGER, 12 MEGAPIXEL. EQUIPPED WITH MULTIPLE ON BOARD MICROPHONES AND AI ANALYTICS

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

XNF-A9014RV

AutoCAD SHX Text

USE T-BAR ABOVE CEILING

AutoCAD SHX Text

SBV-160BW -PLATE

AutoCAD SHX Text

SBP-300WMW1-ARM SBP-160HMW1-CAP SBP-300NBW-BOX

AutoCAD SHX Text

SBP-300WMW1-ARM SBP-160HMW1-CAP SBP-300NBW-BOX SBP-300KMW1-MOUNT

AutoCAD SHX Text

NA

AutoCAD SHX Text

INDOOR SHORT DISTANCE CAMERA. 2MP. DROP OR HARD CEILING

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

XND-A6084RV

AutoCAD SHX Text

USE T-BAR ABOVE CEILING

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

INDOOR DOME CAMERA 4K,8 MEGAPIXEL. EQUIPPED WITH MULTIPLE ON-BOARD MICROPHONES

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

XND-A9084RV

AutoCAD SHX Text

USE T-BAR ABOVE CEILING

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

INDOOR PTZ CAMERA. VISITING ROOM. DROP OR HARD CEILING

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

XNP-6120HW

AutoCAD SHX Text

SHP-1680FPW RECESS MOUNT W/T-BAR

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

OBSERVATION CELL CAMERA. ANTI-LIGATURE. CORNER MOUNT

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

TNV-C7013RV

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

FREEZER CAMERA - OUTDOOR IR FISHEYE

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

XNF-A8014RV

AutoCAD SHX Text

NA

AutoCAD SHX Text

SBV-180WW

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text MULTI-HEAD CAMERA 180/270/360 DEGREES 4x4K LENSES, MOUNT ON BUILDING, POLE OR CORNER OF BLDG. PROVIDE CORRECT MOUNTS. REMOTE AIMABLE.

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

PNM-C32083RQZ

AutoCAD SHX Text

SHD-315F 2X2 TILE REPLACEMENT

AutoCAD SHX Text

NONE REQ'D

AutoCAD SHX Text

SBP-315HMW-CAP SBP-300WMW1-ARM SBP-300NBW-BOX

AutoCAD SHX Text

SBP-315HMW-CAP SBP-300WMW1-ARM SBP-300NBW-BOX SBP-300KMW1-MOUNT

AutoCAD SHX Text

SBP-315HMW-CAP SBP-300WMW1-ARM SBP-300NBW-BOX SBP-300PMW2-POLE SBP-150S-STRAP

AutoCAD SHX Text MULTI-HEAD CAMERA 180/270/360 DEGREES 4x4K LENSES, MOUNT ON BUILDING, POLE OR CORNER OF BLDG. PROVIDE CORRECT MOUNTS. SHALL INCLUDE PTZ CAMERA. FIXED CAMERAS ARE REMOTE AIMABLE.

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

PNM-C34404RQPZ

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

SBP-300WMW-ARM SBP-300NBW-BOX

AutoCAD SHX Text

SBP-300WMW-ARM SBP-300NBW-BOX SBP-300KMW1-MOUNT

AutoCAD SHX Text

SBP-300WMW-ARM -ARM SBP-300NBW-BOX SBP-300PMW2-POLE SBP-150S-STRAP

AutoCAD SHX Text

2-SENSOR CAMERA. SURFACE MOUNT-INDOOR TWO 6MP SENSORS

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

PNM-C12083RVD

AutoCAD SHX Text

USE T-BAR ABOVE CEILING

AutoCAD SHX Text

NONE REQ'D

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

180 DEGREE, PANORAMIC, INDOOR/OUTDOOR MULTI-SENSOR DOME CAMERA

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

PNM-A13022RV

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text

NONE REQ'D

AutoCAD SHX Text

NA

AutoCAD SHX Text

NA

AutoCAD SHX Text RACK MOUNT SHELF FOR PTZ POWER INJECTORS. INSTALL WHERE REQUIRED IN EACH BUILDING TO SUPPORT PTZ INJECTORS AND OTHER DEVICES THAT SHALL BE IN THE RACK.

AutoCAD SHX Text

MIDDLE ATLANTIC

AutoCAD SHX Text

UFA-14.5

AutoCAD SHX Text

NOTE

AutoCAD SHX Text CONTRACTOR SHALL PROVIDE ALL FACTORY MOUNTING EQUIPMENT/PARTS FOR CAMERAS BASED ON THE MOUNTING LOCATION

AutoCAD SHX Text

CB

AutoCAD SHX Text

CC

AutoCAD SHX Text

CD

AutoCAD SHX Text

CE

AutoCAD SHX Text

CF

AutoCAD SHX Text

CG

AutoCAD SHX Text

CH

AutoCAD SHX Text

CJ

AutoCAD SHX Text

CK

AutoCAD SHX Text

CL

AutoCAD SHX Text

CM

AutoCAD SHX Text

CN

AutoCAD SHX Text VIDEO SECURITY RECORDING AND FAILOVER ARCHIVER FOR STORING AND PROCESSING VIDEO. PROVIDE AND INSTALL ARCHIVERS WITH THE PROCESSING AND STORAGE TO MEET THE OWNERS NEED AS DETAILED ON THE DRAWINGS AND SPECS.

AutoCAD SHX Text

GENETEC STREAMVAULT

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text GENETEC DIRECTORY SERVER. INSTALL AND CONNECT. THERE SHALL BE ONE DIRECTORY SERVER AND ONE FAILOVER DIRECTORY SERVER AT THE SITE.

AutoCAD SHX Text

GENETEC STREAMVAULT

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text GENETEC CENTRAL CONTROL MONITORING PC. MUST MEET GENETEC STANDARDS FOR VIEWING STATIONS. INCLUDE WINDOWS 11. SHALL ALSO INCLUDE FOUR (4) HDMI OUTPUTS AT 4k RESOLUTION.

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text GENETEC STANDARD MONITORING PC. MUST MEET GENETEC "HIGH PERFORMANCE" STANDARDS FOR VIEWING STATIONS. INCLUDE WINDOWS 11. SHALL ALSO INCLUDE FOUR (4) HDMI OUTPUTS AT 4k RESOLUTION.

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text

SEE SPECS FOR SMALLER SIZE PC AT WARDEN CONF.

AutoCAD SHX Text GENETEC MINI MONITORING PC. MUST MEET GENETEC "RECOMMENDED" STANDARDS FOR VIEWING STATIONS. PROVIDE PC AND MOUNT TO BACK OF LCD DISPLAY.

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text

13" LAPTOP FOR VIEWING VIDEO AND MAINTAINING THE VIDEO SYSTEM. SEE SPECS.

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text

WIRELESS KEYBOARD/MOUSE KIT.

AutoCAD SHX Text

ORION

AutoCAD SHX Text

BCD-WS-KBM-W

AutoCAD SHX Text KVM SWITCH. SIZE AS REQUIRED FOR ALL ARCHIVE AND DIRECTORY SERVERS PLUS TWO SPARE SERVERS IN THE FUTURE. CONNECT ALL AND PROVIDE CABLING FOR THE TWO SPARE PORTS. LABEL KVM FOR EACH SERVER.

AutoCAD SHX Text

TRIPP LITE

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text WIRED KEYBOARD AND MOUSE. USB ATTACHED. KEYBOARD SHALL BE MINI WITH NO NUMBER KEYPAD

AutoCAD SHX Text

PERIDUO

AutoCAD SHX Text 307-B

AutoCAD SHX Text

CPU WALL MOUNT. ADJUSTABLE TO 9" WIDTH AND 23" HEIGHT

AutoCAD SHX Text

RACK SOLUTIONS

AutoCAD SHX Text

WALL-MOUNT-PC

AutoCAD SHX Text GENETEC STANDARD MONITORING PC -SMALL FORM FACTOR. MUST MEET GENETEC "HIGH PERFORMANCE" STANDARDS FOR VIEWING STATIONS. INCLUDE WINDOWS 11. SHALL ALSO INCLUDE FOUR (4) HDMI OUTPUTS AT 4k RESOLUTION.

AutoCAD SHX Text

GENETEC

AutoCAD SHX Text

SVW-T3-S2000

AutoCAD SHX Text BLU-RAY DVD DUPLICATOR. EQUIP WITH BUILT-IN USB 3.0 FOR DIRECT PC CONNECTION AND 500 GB HDD INTERNAL DRIVE.

AutoCAD SHX Text

EX-DUPE

AutoCAD SHX Text Blu-Ray 16X EZDBR058

AutoCAD SHX Text

EXTERNAL DVD/BLU-RAY WRITER AND READER. EQUIP WITH 400 BLU-RAY DVD'S

AutoCAD SHX Text

OWC

AutoCAD SHX Text

OWCMR3UBDRW16

AutoCAD SHX Text

SD

AutoCAD SHX Text

SC

AutoCAD SHX Text

SB

AutoCAD SHX Text

SA

AutoCAD SHX Text

SE

AutoCAD SHX Text

SF

AutoCAD SHX Text

SG

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text

CCC-YYXX

AutoCAD SHX Text R

AutoCAD SHX Text 2G

AutoCAD SHX Text

TWO-GANG BOX - PROVIDED BY EC

AutoCAD SHX Text

NIC

AutoCAD SHX Text

NOT IN CONTRACT

AutoCAD SHX Text

AC

AutoCAD SHX Text ABOVE COUNTER - INSTALL BACKBOX SAME HEIGHT AS OTHER ELECTRICAL OUTLETS ABOVE THE COUNTER.

AutoCAD SHX Text

PBO

AutoCAD SHX Text

PROVIDED BY OTHERS

AutoCAD SHX Text

AFF

AutoCAD SHX Text

ABOVE FINISHED FLOOR

AutoCAD SHX Text

PCO-1

AutoCAD SHX Text

PATCH CORD ORGANIZER - 1 UNIT HIGH

AutoCAD SHX Text

AFG

AutoCAD SHX Text

ABOVE FINISHED GROUND

AutoCAD SHX Text

PCO-2

AutoCAD SHX Text

PATCH CORD ORGANIZER - 2 UNITS HIGH

AutoCAD SHX Text

AWG

AutoCAD SHX Text

AMERICAN WIRE GAUGE

AutoCAD SHX Text

PER

AutoCAD SHX Text

PROTECTED ENTRANCE TERMINAL

AutoCAD SHX Text

C-EMT

AutoCAD SHX Text

EMT TYPE CONDUIT

AutoCAD SHX Text

QTY

AutoCAD SHX Text

QUANITY

AutoCAD SHX Text

EC

AutoCAD SHX Text

ELECTRICAL CONTRACTOR

AutoCAD SHX Text X

AutoCAD SHX Text NETWORK SWITCH WITH 8 PoE PORTS. OUTDOOR AND WIDE TEMPERATURE RANGE. SHALL HAVE THE FIBER OPTIC MODULES TO CONNECT TO ADMIN SWITCH. EQUIP WITH ALL APPROPRIATE SFP MODULES REQUIRED FOR A FULLY OPERATIONAL SYSTEM. PROVIDE A POWER SUPPLY FOR EACH SWITCH TO ALLOW 60 PoE WATTS PER PORT.

AutoCAD SHX Text

COMNET

AutoCAD SHX Text

CNGE11FX3TX8MSPOEHOK. INCLUDE POWER SUPPLY AND SFP MODULES

AutoCAD SHX Text CORE ETHERNET SWITCH. CONNECT TO FIBER BACKBONE AND SERVERS. EQUIP WITH PORTS AND SFP MODULES. 10 GIGABIT CONNECTIVITY TO ALL BUILDINGS AND SERVERS. 1 GIGABIT CONNECTIVITY TO ALL PERIMETER CABINETS.

AutoCAD SHX Text

CISCO

AutoCAD SHX Text

C9500 SERIES C9500-48Y4C-A

AutoCAD SHX Text CORE ETHERNET SWITCH. SHALL PROVIDE 10gIG CONNECTIVITY TO THE CORE SWITCHES. SHALL PROVIDE NO LESS THAN 48 PoE+ PORTS.

AutoCAD SHX Text

CISCO

AutoCAD SHX Text C9200L-48P-4X-E

AutoCAD SHX Text ETHERNET SWITCH - IN A BUILDING FOR CONNECTIVITY TO CAMERAS AND USER PC'S. 48 COPPER PORTS POE+ WITH 10 GIGABIT SFP MODULE. VERIFY FIBER TYPE.

AutoCAD SHX Text

CISCO

AutoCAD SHX Text C9200L-48P-4X-E

AutoCAD SHX Text NEW PoE INJECTOR TO BE PROVIDED FOR ALL NEW AND EXISTING PTZ CAMERAS MOUNTED TO THE BUILDING EXTERIOR.

AutoCAD SHX Text

HANWHA

AutoCAD SHX Text

SPO-8315

AutoCAD SHX Text

NA

AutoCAD SHX Text

NB

AutoCAD SHX Text

NC

AutoCAD SHX Text

ND

AutoCAD SHX Text

NE

AutoCAD SHX Text

SH

AutoCAD SHX Text

SJ

AutoCAD SHX Text

SK

AutoCAD SHX Text

24 STRAND, SINGLEMODE FIBER CABLE. INDOOR/OUTDOOR RATED.

AutoCAD SHX Text

OCC

AutoCAD SHX Text

DX024TSLX9YP

AutoCAD SHX Text

NOT USED

AutoCAD SHX Text

EXTERIOR RATED CAT-6A CABLE FOR ETHERNET CONNECTIVITY.

AutoCAD SHX Text

BELDEN

AutoCAD SHX Text

OSB6U

AutoCAD SHX Text

PLENUM RATED, GREEN, CAT-6 CABLE FOR ETHERNET CONNECTIVITY.

AutoCAD SHX Text

MOHAWK

AutoCAD SHX Text M58286

AutoCAD SHX Text LONG DISTANCE, PLENUM RATED CABLE. USE FOR CAMERAS MORE THAN 300' AWAY FROM THE COMM ROOM.

AutoCAD SHX Text

GAME CHANGER

AutoCAD SHX Text 258300310

AutoCAD SHX Text LONG DISTANCE, OUTDOOR RATED CABLE. USE FOR CAMERAS MORE THAN 300' AWAY FROM THE COMM ROOM.

AutoCAD SHX Text

GAME CHANGER

AutoCAD SHX Text 258340804

AutoCAD SHX Text HDMI MALE TO MALE CABLE, LENGTH AS SHOWN. CONNECT PC TO PLATE. ACTIVE HDMI TO SUPPORT DISTANCES UP TO 75'

AutoCAD SHX Text

LEGRAND

AutoCAD SHX Text

CONTRACTOR

AutoCAD SHX Text

CAT-6 UTP CABLES FOR ACCESS CONTROL CONNECTIONS. PINK COLOR

AutoCAD SHX Text

MOHAWK

AutoCAD SHX Text M58282

AutoCAD SHX Text

PLENUM RATED CAT-6 CABLE FOR VIDEO TRANSMISSION

AutoCAD SHX Text

MOHAWK

AutoCAD SHX Text

VARIOUS

AutoCAD SHX Text

ACCESS CONTROL CABLE. COMBO CABLE FOR CR, DC, ES/EL ETC-PLENUM- PINK IN COLOR

AutoCAD SHX Text

CONTRACTOR

AutoCAD SHX Text

CONTRACTOR

AutoCAD SHX Text INDIVIDUAL SECURITY DEVICE CABLE. PROVIDE AS PER MANUFACTURERS REQUIREMENTS. -PLENUM RATED. PINK IN COLOR

AutoCAD SHX Text

CONTRACTOR

AutoCAD SHX Text

CONTRACTOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ACCESS CONTROL SYSTEM, SOFTWARE TO BE ADDED TO EXISTING CAMERA SERVER

AutoCAD SHX Text

GENETEC

AutoCAD SHX Text

GSC-SY-S

AutoCAD SHX Text

ACCESS CONTROL ENCLOSURE. BACKPLATE AND LOCKABLE PANEL

AutoCAD SHX Text

ALTRONIX

AutoCAD SHX Text

TROVE 1/2/3

AutoCAD SHX Text POWER SUPPLY FOR ACCESS CONTROL EQUIPMENT. EQUIP WITH ETHERNET CONNECTIVITY MODULE

AutoCAD SHX Text

ALTRONIX

AutoCAD SHX Text

E-FLOW SERIES W/ LINQ2 ENET MOD.

AutoCAD SHX Text POWER DISTRIBUTION BOARD AND VOLTAGE REGULATOR. POWERS OTHER BOARDS IN THE ACCESS CTRL PANEL

AutoCAD SHX Text

ALTRONIX

AutoCAD SHX Text

PDS8 SERIES WITH VR6 REGULATOR

AutoCAD SHX Text

ACCESS POWER CONTROLLER

AutoCAD SHX Text

ALTRONIX

AutoCAD SHX Text

ACMS8 OR EQUAL

AutoCAD SHX Text

DOOR ACCESS CONTROL MODULE. IP ATTACHED. QTY AS REQUIRED

AutoCAD SHX Text

GENETEC

AutoCAD SHX Text

SY-LP4502

AutoCAD SHX Text

DOOR ACCESS CONTROL MODULE. RS-485 ATTACHED. QTY AS REQUIRED

AutoCAD SHX Text

GENETEC

AutoCAD SHX Text

SY-MR52-S3

AutoCAD SHX Text

ACCESS CONTROL SYSTEM CONTROLLER/APPLIANCE

AutoCAD SHX Text

GENETEC

AutoCAD SHX Text

SY-CLOUDLINK

AutoCAD SHX Text

CARD READER. MOUNT ON A SINGLE GANG BOX

AutoCAD SHX Text

GENETEC

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text

BATTERY FOR ACCESS CONTROL PANEL

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text

SEE SPECS

AutoCAD SHX Text

INTERCOM BASE STATION

AutoCAD SHX Text

AIPHONE

AutoCAD SHX Text

IX-MV7-HW-JP

AutoCAD SHX Text

IP PROGRAMMABLE RELAY

AutoCAD SHX Text

AIPHONE

AutoCAD SHX Text

IXW-MA

AutoCAD SHX Text INTERCOM -SURFACE MOUNT. EQUIP WITH CUSTOM BACKBOX AND PUSHBUTTON BELOW. CUSTOM WIRE TO SUPPORT ADA APPROVED CALL BUTTON HEIGHT

AutoCAD SHX Text

AIPHONE /ALARM CONTROLS

AutoCAD SHX Text

IX-DVF

AutoCAD SHX Text

DUAL FREQUENCY READER THAT SUPPORT MOBILE ACCESS. USB ATTACHED

AutoCAD SHX Text

HID

AutoCAD SHX Text

OMNIKEY 5427CK

AutoCAD SHX Text

CARD PRINTER

AutoCAD SHX Text

FARGO

AutoCAD SHX Text

DTC1250E

AutoCAD SHX Text

PD

AutoCAD SHX Text

PC

AutoCAD SHX Text

PB

AutoCAD SHX Text

PA

AutoCAD SHX Text

PE

AutoCAD SHX Text

PF

AutoCAD SHX Text

PG

AutoCAD SHX Text

PH

AutoCAD SHX Text

PJ

AutoCAD SHX Text

PL

AutoCAD SHX Text

PM

AutoCAD SHX Text

PN

AutoCAD SHX Text

PO

AutoCAD SHX Text

PP

AutoCAD SHX Text

PQ

AutoCAD SHX Text THIS SYMBOL WITH A NUMBER INSIDE REFERS TO KEYNOTES. REFER TO NOTES ON THE SHEET FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text EQUIPMENT SCHEDULE. THIS SYMBOL WITH LETTERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.

AutoCAD SHX Text CABLE SCHEDULE. THIS SYMBOL WITH NUMBERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.

AutoCAD SHX Text ACCESS CONTROL SYMBOL. "XX" IS LETTERS. SEE DETAILS ON TC5XX SHEETS FOR EQUIPMENT, CABLING AND RACEWAY DETAILS.

AutoCAD SHX Text ACCESS CONTROL SYMBOL FOR EXISTING DEVICES. "XX" IS LETTERS. SEE DETAILS ON TC5XX SHEETS. LEAVE DEVICES AND CONNECT TO NEW SYSTEM OR LEAVE AS CONNECTED TO EXISTING SYSTEM. SEE NOTES AND DETAILS

AutoCAD SHX Text SECURITY CAMERA AT NEW LOCATION. PROVIDE AND INSTALL A NEW SECURITY CAMERA. SEE DETAILS ON TC1XX SHEETS.

AutoCAD SHX Text SECURITY CAMERA WITH 180 DEGREE VIEWING. PROVIDE AND INSTALL A NEW SECURITY CAMERA. SEE DETAILS ON TC1XX SHEETS.

AutoCAD SHX Text SECURITY CAMERA WITH 360 DEGREE VIEWING, SINGLE-IMAGER. PROVIDE AND INSTALL A NEW SECURITY CAMERA. SEE DETAILS ON TC1XX SHEETS.

AutoCAD SHX Text SECURITY CAMERA WITH 360 DEGREE VIEWING, MULTI-IMAGER. PROVIDE AND INSTALL A NEW SECURITY CAMERA. SEE DETAILS ON TC1XX SHEETS.

AutoCAD SHX Text EXISTING SECURITY CAMERA TO REMAIN. LEAVE IN PLACE AND CONFIGURE ON NEW VMS SYSTEM.

AutoCAD SHX Text CAMERA NUMBER AND CABLE TO BE USED FOR REPLACEMENT OF EXISTING CAMERA AT THE SAME LOCATION. CONFIGURE NEW CAMERA ON NEW VMS SYSTEM.

AutoCAD SHX Text EXISTING SECURITY CAMERA TO BE REMOVED. PROVIDE ALL PATCHING OF WALL OR CEILING PENETRATION AS REQ'D.

AutoCAD SHX Text COMPUTER. PROVIDE AND INSTALL A PC FOR THE SECURITY SYSTEM. SEE DETAILS ON TC1XX SHEETS FOR REQUIREMENTS.

AutoCAD SHX Text LAPTOP COMPUTER. PROVIDE AND INSTALL A LAPTOP FOR THE SECURITY SYSTEM. SEE DETAILS ON TC1XX SHEETS FOR REQUIREMENTS.

AutoCAD SHX Text

CAMERA IDENTIFIER - CCC = SITE CODE - YY = BUILDING NUMBER/XX = CAMERA NUMBER.

AutoCAD SHX Text

POLE IDENTIFIER - PL = POLE

AutoCAD SHX Text NEW CAMERA POLE - CONTRACTOR TO INSTALL NEW POLE AT THIS LOCATION TO SUPPORT NEW CAMERA LOCATION. SEE ELECTRICAL DRAWINGS.

AutoCAD SHX Text NEW PERIMETER NETWORK CABINET WITH FIBER CONNECTIVITY. CABINET PROVIDES LOCAL CONNECTIONS TO CAMERAS AND LIGHTING FOR CONTROL. REFER TO DETAILS FOR CABINET EQUIPMENT BUILD OUTS.

AutoCAD SHX Text MONITOR AND MOUNT LOCATION - REFER TO DETAILS FOR MOUNTING AND CABLING REQUIREMENTS.

AutoCAD SHX Text SECURITY PANEL. PROVIDE PANEL AND CONNECT AS SHOWN ON FLOORPLANS AND IN THE SPECIFICATIONS.

AutoCAD SHX Text

DOOR NUMBER

AutoCAD SHX Text

CAB-XXX

AutoCAD SHX Text P

AutoCAD SHX Text

LCD.XX"

AutoCAD SHX Text

XXX

AutoCAD SHX Text

SEC.PNL

AutoCAD SHX Text

XX

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

XX

AutoCAD SHX Text

SL

AutoCAD SHX Text SEE ATTIC STOCK SPECIFICATION 28 7100 FOR EQUIPMENT TO BE PROVIDED AS PART OF ATTIC STOCK

AutoCAD SHX Text

SM

AutoCAD SHX Text 2-POST RACK:7'x19" BLACK RELAY RACK EQUIPPED WITH ONE FULL-LENGTH 6" VERTICAL ORGANIZER. RELAY RACK IS TO BE CONFIGURED WITH VERTICAL & HORIZONTAL CABLE LADDER AS SHOWN ON THE DRAWINGS AND AS DESCRIBED IN THE SPECS. EACH RACK SHALL BE CONFIGURED WITH ONE (1) 6" WIDE VERTICAL ORGANIZER.

AutoCAD SHX Text

ORTRONICS

AutoCAD SHX Text

19-84-T2SD-B/

AutoCAD SHX Text 4-POST ADJUSTABLE RACK. PUNCHED 3/8" HOLES. EQUIP WITH TWO 6" VERTICAL ORGANIZERS. EQUIP WITH CAGE NUTS FOR 19" RACK COMPONENTS. EQUIP WIITH CABLE LADDER AS PER SPECS AND DETAILS.

AutoCAD SHX Text

ORTRONICS

AutoCAD SHX Text

19-84-SSDA2132

AutoCAD SHX Text POWER STRIP, VERTICAL, FOR BACK OF EACH RACK. SHALL HAVE (6) NEMA 5-20R RECEPTACLES AND SHALL BE 18" LONG. PLUG INTO WALL OUTLET. ATTACH THE POWER STRIP TO THE BACK OF THE VERTICAL CABLE LADDER OF EACH RACK.

AutoCAD SHX Text

SEE ELECTRICAL

AutoCAD SHX Text

SEE ELECTRICAL SPECS

AutoCAD SHX Text

SINGLE RACK UNIT PATCH CORD ORGANIZER (PCO-1) WITH HINGED COVER.

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

HS13C

AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR JACKS TO MATCH THE CABLE COLOR AND CABLE TYPE BEING TERMINATED. PROVIDE ONE MODULAR JACK FOR EACH CABLE BEING TERMINATED. SEE SPEC AND DRAWINGS FOR COLORS. EQUIP WITH REAR CABLE ORGANIZER.

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

PANEL:HPJ24 ORGANIZER:HPRCMB

AutoCAD SHX Text RACK MOUNT FIBER PANEL. USE WHEN TERMINATING 24 OR LESS FIBER STRANDS. PROVIDE EACH FIBER PANEL WITH "LC" 12 OR 24 PACKS AS REQUIRED FOR TERMINATION OF ALL FIBERS. PROVIDE SPLICE TRAY AND SHELF FOR FUSION SPLICES TO PIGTAILS.

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

FPR3SP

AutoCAD SHX Text EXISTING WALL MOUNT FIBER PANEL. USE WHEN TERMINATING UP TO 48 FIBER STRANDS. FIBER PANEL EXISTS. REPLACE SC FSP MODULES WITH NEW "LC" 12 OR 24 PACKS AS REQUIRED FOR TERMINATION OF ALL FIBERS. PROVIDE NEW SPLICE TRAY AND SHELF FOR FUSION SPLICES TO PIGTAILS.

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

EXISTING. PROVIDE NEW LC FSP MODULES AND SPLICES

AutoCAD SHX Text FIBER OPTIC CABLE STOWAGE RING. WALL MOUNTED. 12" OR 24". PROVIDE AND INSTALL TO SUPPORT BEND RADIUS REQUIREMENTS OF THE FIBER CABLE.

AutoCAD SHX Text

LEVITON

AutoCAD SHX Text

12" #48900-IFR / 24" #48900-OFR

AutoCAD SHX Text

CAT-6 POE LIGHTNING ARRESTOR. INSTALL AND CONNECT TO GROUND WITH WIRE.

AutoCAD SHX Text

SEE ELECTRICAL SPECS

AutoCAD SHX Text

SEE ELECTRICAL SPECS

AutoCAD SHX Text

SURFACE MOUNT BOX FOR NEW CABLES IN PERIMETER CABINET. SIZE AS REQUIRED.

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

HSB SERIES.

AutoCAD SHX Text WALL MOUNT RACK. SHALL BE SWING GATE RACK. EQUIP WITH HEAVY DUTY SWING GATE KIT AND CABLE ROUTING ACCESSORIES.

AutoCAD SHX Text

CHATSWORTH

AutoCAD SHX Text

11792-X25 W/HEAVY DUTY SWING KIT

AutoCAD SHX Text

GUARD DESK WITH SLIDING MOUSE TRAY. GRAY IN COLOR. REMOVE CASTERS AND INSTALL.

AutoCAD SHX Text

GLOBAL INDISTRIAL

AutoCAD SHX Text

T9F706669GY W/273113

AutoCAD SHX Text VERTICAL ORGANIZER FOR MOUNTING TO THE SIDE OF A RACK. WHERE THE RACK IS LESS THAN 7', CUT OFF VERTICAL ORGANIZER TO FIT RACK.

AutoCAD SHX Text

RLX

AutoCAD SHX Text

3326-BJ06

AutoCAD SHX Text TELECOMMUNICATIONS GROUND BAR (TGB). 1/4"x4"x10" EQUIPPED WITH INSULATED STAND-OFFS.

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

HBBB14210A

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text D

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text H

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text J

AutoCAD SHX Text K

AutoCAD SHX Text L

AutoCAD SHX Text M

AutoCAD SHX Text N

AutoCAD SHX Text

SN

AutoCAD SHX Text 21" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS. PROVIDE A TABLE TOP MOUNT AND ALL CABLING REQUIRED. NATIVE 4K VIDEO RESOLUTION

AutoCAD SHX Text

LG

AutoCAD SHX Text

22MD4KA-B

AutoCAD SHX Text

22" LCD MONITOR. HD RESOLUTION.

AutoCAD SHX Text

NEC

AutoCAD SHX Text

EA224WMI-BK

AutoCAD SHX Text 27" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS. PROVIDE A TABLE TOP MOUNT AND ALL CABLING REQUIRED. NATIVE 4K VIDEO RESOLUTION

AutoCAD SHX Text

NEC

AutoCAD SHX Text

DD-EA272U

AutoCAD SHX Text 32" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS. PROVIDE A WALL OR CEILING MOUNT AS REQUIRED IN THE FIELD AND ALL CABLING REQUIRED. NATIVE 4K VIDEO RESOLUTION

AutoCAD SHX Text

SHARP

AutoCAD SHX Text

PN-M322

AutoCAD SHX Text 43" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS. PROVIDE A TABLE TOP MOUNT AND ALL CABLING REQUIRED. NATIVE 4K VIDEO RESOLUTION

AutoCAD SHX Text

NEC

AutoCAD SHX Text

4PB43EJ2U

AutoCAD SHX Text 55" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS. PROVIDE A MONITOR MOUNT AND ALL CABLING REQUIRED. NATIVE 4K VIDEO RESOLUTION

AutoCAD SHX Text

SHARP

AutoCAD SHX Text

PN-M552

AutoCAD SHX Text 65" FLAT PANEL. EQUIP WITH A MOUNT. PROVIDE A MONITOR MOUNT AND ALL PROVIDE A MONITOR MOUNT AND ALL CABLING REQUIRED. NATIVE 4K VIDEO RESOLUTION. NATIVE 4K VIDEO RESOLUTION

AutoCAD SHX Text

SHARP

AutoCAD SHX Text

PN-M652

AutoCAD SHX Text 75" FLAT PANEL. EQUIP WITH A MOUNT. PROVIDE A MONITOR MOUNT AND ALL PROVIDE A MONITOR MOUNT AND ALL CABLING REQUIRED. NATIVE 4K VIDEO RESOLUTION. NATIVE 4K VIDEO RESOLUTION

AutoCAD SHX Text

SHARP

AutoCAD SHX Text

PN-M752

AutoCAD SHX Text CEILING MOUNT FOR 32" OR 43" DISPLAY. PROVIDE CEILING ADAPTER AND CUSTOM DOWNPIPE.WHERE PC IS TO BE MOUNTED, INCLUDE PC MOUNT

AutoCAD SHX Text

CHIEF

AutoCAD SHX Text

MCM1U W/ADAPTER CPA330. PC MOUNT FCA515

AutoCAD SHX Text

PULL OUT MOUNT FOR FLAT PANEL 32" AND 43" DISPLAY

AutoCAD SHX Text

CHIEF

AutoCAD SHX Text

TS218SU

AutoCAD SHX Text

PULL OUT MOUNT FOR FLAT PANEL 55"

AutoCAD SHX Text

CHIEF

AutoCAD SHX Text

TS325TU

AutoCAD SHX Text

PULL OUT MOUNT FOR FLAT PANEL 65" AND 75"

AutoCAD SHX Text

CHIEF

AutoCAD SHX Text

TS525TU

AutoCAD SHX Text AT EACH DISPLAY WHERE THERE ARE DEVICES TO BE INSTALLED BEHIND THE FLAT PANEL DISPLAY, INSTALL A COMPONENT STORAGE PANEL

AutoCAD SHX Text

CHIEF

AutoCAD SHX Text

CSMP9X12

AutoCAD SHX Text

MONITOR HOOD FOR 27" MONITORS.

AutoCAD SHX Text

VIEWSONIC

AutoCAD SHX Text

MH27M1

AutoCAD SHX Text

MONITOR PRIVACY SCREEN 27" - DESKTOP SECURITY AND FILTER PROTECTOR.

AutoCAD SHX Text 3M

AutoCAD SHX Text

PF270W9B

AutoCAD SHX Text

PC ENCLOSURE. MOUNT ON WALL

AutoCAD SHX Text

AFC INDUSTRIES

AutoCAD SHX Text 772445

AutoCAD SHX Text

RACK MOUNT SHELF. ATTACH TO FRONT RACK RAILS. 14.5" DEEP

AutoCAD SHX Text

MIDDLE ATLANTIC

AutoCAD SHX Text

UFA-14.5

AutoCAD SHX Text

PTZ VIDEO CONFERENCE CAMERA

AutoCAD SHX Text

LOGITECH

AutoCAD SHX Text

PTZ PRO 2

AutoCAD SHX Text

MICROPHONE AND SPEAKER COMBO DEVICE. DESKTOP, USB ATTACHED

AutoCAD SHX Text

EMEET

AutoCAD SHX Text

OFFICE CORE M2 MAX

AutoCAD SHX Text

CONTROL PANEL. 6-BUTTON CONTROLLER WITH INTERFACE PLATE

AutoCAD SHX Text

KRAMER

AutoCAD SHX Text

RC-306

AutoCAD SHX Text

HDMI/USB SWITCHERS, TRANSMITTER AND RECEIVER

AutoCAD SHX Text

KRAMER

AutoCAD SHX Text

SWT-21-HU-TR

AutoCAD SHX Text

USB DOCKING STATION FOR LAPTOP. WITH DUAL HDMI OUT

AutoCAD SHX Text

DELL

AutoCAD SHX Text D3100

AutoCAD SHX Text

DESTKOP FACEPLATE WEDGE. 1-GANG. PROVIDE AND MOUNT PLATE

AutoCAD SHX Text

FSR

AutoCAD SHX Text

DSKB-1G

AutoCAD SHX Text

TABLE TOP POWER TOWER WITH USB CHARGING PORTS

AutoCAD SHX Text

NTONPOWER

AutoCAD SHX Text

8-120 VOLT, 2-USBA, 2-USBC

AutoCAD SHX Text

ETHERNET SWITCH. MOUNT ON BACK OF PC ENCLOSURE

AutoCAD SHX Text

NETGEAR

AutoCAD SHX Text

GS305PP

AutoCAD SHX Text

CONTACT CLOSURE BUTTON AND CABLE. CONNECT AND TEST

AutoCAD SHX Text

KRAMER

AutoCAD SHX Text

RC-10TB

AutoCAD SHX Text

55" MONITOR PRIVACY SCREEN

AutoCAD SHX Text

DELL

AutoCAD SHX Text

AMDHZ

AutoCAD SHX Text

XA

AutoCAD SHX Text

XB

AutoCAD SHX Text

XC

AutoCAD SHX Text

XD

AutoCAD SHX Text

XE

AutoCAD SHX Text

XF

AutoCAD SHX Text

XG

AutoCAD SHX Text

XH

AutoCAD SHX Text

XK

AutoCAD SHX Text

XL

AutoCAD SHX Text

XM

AutoCAD SHX Text

XN

AutoCAD SHX Text

XO

AutoCAD SHX Text

XP

AutoCAD SHX Text

XQ

AutoCAD SHX Text

XS

AutoCAD SHX Text

XU

AutoCAD SHX Text

XV

AutoCAD SHX Text

XX

AutoCAD SHX Text

YA

AutoCAD SHX Text

YC

AutoCAD SHX Text

YD

AutoCAD SHX Text

YE

AutoCAD SHX Text

YF

AutoCAD SHX Text

YB

AutoCAD SHX Text

YG

AutoCAD SHX Text

AutoCAD SHX Text

YH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SHEET NUMBER

AutoCAD SHX Text

472/23198.JGH

AutoCAD SHX Text file no.

AutoCAD SHX Text checked by

AutoCAD SHX Text drawn by

AutoCAD SHX Text consultant

AutoCAD SHX Text issue date

AutoCAD SHX Text acctg template.

AutoCAD SHX Text contract order no.

AutoCAD SHX Text 472ICFMaintproj

AutoCAD SHX Text consultant job no.

AutoCAD SHX Text 1065_24B

AutoCAD SHX Text sheet title

AutoCAD SHX Text

VIDEO…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .