472-21303_MAA_Thumb_Video Management SystemUpgrades _ Bid Drawings 20220718 Part 1 of 3.pdf
PDF 5 MB Posted
- Solicitation number
- RFQ - 171 - 220000000458
- Issued by
- Tuscola County, Capac Village, Michigan
About this file
This document appears to be a bid package for the Thumb Correctional Facility Video Management System Upgrade - Phase 1 project, issued by the State of Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division.
The project involves upgrading the video management system at the Thumb Correctional Facility located in Lapeer, Michigan. The work includes demolition and new installation of cameras, cabling, cabinets, and related equipment. The bid package contains electrical and security drawings showing the existing conditions and new work to be performed. Bids are due by July 15, 2022, and the contract award date is not specified. The contract term and any renewal options are also not provided.
The bid package includes pricing schedules, equipment specifications, installation details, and grounding requirements. No information is given on any set asides, incumbent contractors, funding sources, or budgets for the project. The successful bidder will need to coordinate with the owner and adhere to site safety protocols related to the COVID-19 pandemic.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING LIST:
TC101 THUMB SECURITY LEGENDS, DETAILS AND SCHEDULES
TC102 THUMB DATA CABLING AND SECURITY MOUNTING DETAILS
TC103 THUMB SECURITY MOUNTING DETAILS
TC104 THUMB NEW CAMERA ON POLE CONNECTIVITY & SURGE PROTECTION DETAILS
TC105 THUMB FIBER BACKBONE CONNECTIVITY
TC106 THUMB RACK LAYOUTS
TC107 THUMB RACK LAYOUTS
TC108 THUMB RACK LAYOUTS
TC109 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC110 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC111 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC112 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC113 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC114 THUMB SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER
TC115 THUMB SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER
TC201 THUMB 100 ADMINISTRATION - FIRST & SECOND FLOORS - EXISTING
TC202A THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA A - EXISTING
TC202B THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA B - EXISTING
TC202C THUMB 200 SUPPORT SERVICES - SECOND FLOOR - AREA A - EXISTING
TC203A THUMB 300 EDUCATION - BASEMENT & FIRST FLOOR - EXISTING
TC203B THUMB 300 EDUCATION - SECOND FLOOR - EXISTING
TC204 THUMB 600 LAUNDRY & 800 GENERATOR ALL FLOORS - EXISTING
TC205A THUMB HOUSING UNIT 700 AUBURN - ALL LEVELS - EXISTING
TC205B THUMB HOUSING UNIT 700 BURNS - ALL LEVELS - EXISTING
TC206A THUMB HOUSING UNIT 400 DURANT - ALL LEVELS - EXISTING
TC206B THUMB HOUSING UNIT 400 CORD - ALL LEVELS - EXISTING
TC207 THUMB HOUSING UNIT 500 ESSEX - ALL LEVELS - EXISTING
TC208A THUMB HOUSING UNIT FRANKLIN - FIRST FLOOR - EXISTING
TC208B THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR - EXISTING
TC209 THUMB CORRECTIONAL FACILITY SITE PLAN - EXISTING
TC301 THUMB 100 ADMINISTRATION - FIRST & SECOND FLOORS - NEW & REPLACE
TC302A THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA A - NEW & REPLACE
TC302B THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA B - NEW & REPLACE
TC302C THUMB 200 SUPPORT SERVICES - SECOND FLOOR - AREA C - NEW & REPLACE
TC303A THUMB 300 EDUCATION BUILDING - FIRST FLOOR - NEW & REPLACE
TC303B THUMB 300 EDUCATION BUILDING - SECOND FLOOR - NEW & REPLACE
TC304 THUMB 600 LAUNDRY & 800 GENERATOR ALL FLOORS - NEW & REPLACE
TC305 THUMB HOUSING UNIT 700 AUBURN - ALL LEVELS - NEW & REPLACE
TC305B THUMB HOUSING UNIT 700 BURNS - ALL LEVELS - NEW & REPLACE
TC306A THUMB HOUSING UNIT 400 DURANT - ALL LEVELS - NEW & REPLACE
TC306B THUMB HOUSING UNIT 400 CORD - ALL LEVELS - NEW & REPLACE
TC307 THUMB HOUSING UNIT 500 ESSEX - ALL LEVELS - NEW & REPLACE
TC308A THUMB HOUSING UNIT FRANKLIN - FIRST FLOOR - NEW & REPLACE
TC308B THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR - NEW & REPLACE
TC309 THUMB CORRECTIONAL FACILITY SITE PLAN - NEW & REPLACE
STATE OF MICHIGAN
THUMB CORRECTIONAL FACILITY
VIDEO MANAGEMENT SYSTEM UPGRADE -PHASE 1
THUMB CORRECTIONAL FACILITY
FILE NUMBER: 472/21303.JBB
3225 John Conley Drive Lapeer, MI 48446
ELECTRICAL ENGINEER
MATRIX CONSULTING ENGINEERS, INC.
1601 EAST GRAND RIVER
LANSING, MI 48906
(517) 487-2511
SECURITY DESIGN
COMMTECH DESIGN
6581 BELDING RD. NE, SUITE 101
ROCKFORD, MI 49341
(616) 863-8132
SECURITY DRAWING INDEXELECTRICAL DRAWING INDEX
THUMB CORRECTIONAL FACILITY
3225 John Conley Drive Lapeer, MI 48446
DRAWING LIST:
E-100 THUMB ELECTRICAL ABBREVIATIONS, SYMBOLS, AND NOTES
E-200 THUMB - SITE PLAN - DEMO
E-201 THUMB - SITE PLAN - NEW
E-501 THUMB 100 ADMIN BUILDING - FIRST FLOOR PLAN - NEW
E-502 THUMB 100 ADMIN BUILDING - SECOND FLOOR PLAN - NEW
E-503 THUMB 200 SUPPORT SERVICES - FIRST FLOOR PLAN - NEW
E-504 THUMB 200 SUPPORT SERVICES - SECOND FLOOR PLAN - NEW
E-505 THUMB 300 EDUCATION - FIRST FLOOR PLAN - NEW
E-506 THUMB 300 EDUCATION - SECOND FLOOR PLAN - NEW
E-507 THUMB 600 LAUNDRY BUILDING - FIRST FLOOR PLAN - NEW
E-508 THUMB HOUSING UNIT 700 AUBURN - UPPER LEVEL FLOOR PLAN - NEW
E-509 THUMB HOUSING UNIT 700 BURNS - UPPER LEVEL FLOOR PLAN - NEW
E-510 THUMB HOUSING UNIT 400 CORD - UPPER LEVEL FLOOR PLAN - NEW
E-511 THUMB HOUSING UNIT 400 DURANT - UPPER LEVEL FLOOR PLAN - NEW
E-512 THUMB HOUSING UNIT 500 ESSEX - UPPER LEVEL FLOOR PLAN - NEW
E-513 THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR PLAN - NEW
E-800 THUMB VIDEO SECURITY DETAILS
E-801 THUMB VIDEO SECURITY DETAILS
E-802 THUMB CAMERA CONNECTIVITY - PERIMETER
COVER
C om m te ch
D es ig n
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a t r ix
TC102 THUMB DATA CABLING AND SECURITY MOUNTING DETAILS
TC103 THUMB SECURITY MOUNTING DETAILS
TC104 THUMB NEW CAMERA ON POLE CONNECTIVITY & SURGE PROTECTION DETAILS
TC105 THUMB FIBER BACKBONE CONNECTIVITY
TC106 THUMB RACK LAYOUTS
TC107 THUMB RACK LAYOUTS
TC108 THUMB RACK LAYOUTS
TC109 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC110 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC111 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC112 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC113 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC114 THUMB SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER
TC115 THUMB SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER
TC201 THUMB 100 ADMINISTRATION - FIRST & SECOND FLOORS - EXISTING
TC202A THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA A - EXISTING
TC202B THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA B - EXISTING
TC202C THUMB 200 SUPPORT SERVICES - SECOND FLOOR - AREA A - EXISTING
TC203A THUMB 300 EDUCATION - BASEMENT & FIRST FLOOR - EXISTING
TC203B THUMB 300 EDUCATION - SECOND FLOOR - EXISTING
TC204 THUMB 600 LAUNDRY & 800 GENERATOR ALL FLOORS - EXISTING
TC205A THUMB HOUSING UNIT 700 AUBURN - ALL LEVELS - EXISTING
TC205B THUMB HOUSING UNIT 700 BURNS - ALL LEVELS - EXISTING
TC206A THUMB HOUSING UNIT 400 DURANT - ALL LEVELS - EXISTING
TC206B THUMB HOUSING UNIT 400 CORD - ALL LEVELS - EXISTING
TC207 THUMB HOUSING UNIT 500 ESSEX - ALL LEVELS - EXISTING
TC208A THUMB HOUSING UNIT FRANKLIN - FIRST FLOOR - EXISTING
TC208B THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR - EXISTING
TC209 THUMB CORRECTIONAL FACILITY SITE PLAN - EXISTING
TC301 THUMB 100 ADMINISTRATION - FIRST & SECOND FLOORS - NEW & REPLACE
TC302A THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA A - NEW & REPLACE
TC302B THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA B - NEW & REPLACE
TC302C THUMB 200 SUPPORT SERVICES - SECOND FLOOR - AREA C - NEW & REPLACE
TC303A THUMB 300 EDUCATION BUILDING - FIRST FLOOR - NEW & REPLACE
TC303B THUMB 300 EDUCATION BUILDING - SECOND FLOOR - NEW & REPLACE
TC304 THUMB 600 LAUNDRY & 800 GENERATOR ALL FLOORS - NEW & REPLACE
TC305 THUMB HOUSING UNIT 700 AUBURN - ALL LEVELS - NEW & REPLACE
TC305B THUMB HOUSING UNIT 700 BURNS - ALL LEVELS - NEW & REPLACE
TC306A THUMB HOUSING UNIT 400 DURANT - ALL LEVELS - NEW & REPLACE
TC306B THUMB HOUSING UNIT 400 CORD - ALL LEVELS - NEW & REPLACE
TC307 THUMB HOUSING UNIT 500 ESSEX - ALL LEVELS - NEW & REPLACE
TC308A THUMB HOUSING UNIT FRANKLIN - FIRST FLOOR - NEW & REPLACE
TC308 B THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR - NEW & REPLACE
TC309 THUMB CORRECTIONAL FACILITY SITE PLAN - NEW & REPLACE
STATE OF MICHIGAN
THUMB CORRECTIONAL FACILITY
VIDEO MANAGEMENT SYSTEM UPGRADE -PHASE 1
THUMB CORRECTIONAL FACILITY
FILE NUMBER: 472/21303.JBB
3225 John Conley Drive Lapeer, MI 48446
ELECTRICAL ENGINEER
MATRIX CONSULTING ENGINEERS, INC.
1601 EAST GRAND RIVER
LANSING, MI 48906
(517) 487-2511
SECURITY DESIGN
COMMTECH DESIGN
6581 BELDING RD. NE, SUITE 101
ROCKFORD, MI 49341
(616) 863-8132
SECURITY DRAWING INDEXELECTRICAL DRAWING INDEX
THUMB CORRECTIONAL FACILITY
3225 John Conley Drive Lapeer, MI 48446
DRAWING LIST:
E-100 THUMB ELECTRICAL ABBREVIATIONS, SYMBOLS, AND NOTES
E-200 THUMB - SITE PLAN - DEMO
E-201 THUMB - SITE PLAN - NEW
E-501 THUMB 100 ADMIN BUILDING - FIRST FLOOR PLAN - NEW
E-502 THUMB 100 ADMIN BUILDING - SECOND FLOOR PLAN - NEW
E-503 THUMB 200 SUPPORT SERVICES - FIRST FLOOR PLAN - NEW
E-504 THUMB 200 SUPPORT SERVICES - SECOND FLOOR PLAN - NEW
E-505 THUMB 300 EDUCATION - FIRST FLOOR PLAN - NEW
E-506 THUMB 300 EDUCATION - SECOND FLOOR PLAN - NEW
E-507 THUMB 600 LAUNDRY BUILDING - FIRST FLOOR PLAN - NEW
E-508 THUMB HOUSING UNIT 700 AUBURN - UPPER LEVEL FLOOR PLAN - NEW
E-509 THUMB HOUSING UNIT 700 BURNS - UPPER LEVEL FLOOR PLAN - NEW
E-510 THUMB HOUSING UNIT 400 CORD - UPPER LEVEL FLOOR PLAN - NEW
E-511 THUMB HOUSING UNIT 400 DURANT - UPPER LEVEL FLOOR PLAN - NEW
E-512 THUMB HOUSING UNIT 500 ESSEX - UPPER LEVEL FLOOR PLAN - NEW
E-513 THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR PLAN - NEW
E-800 THUMB VIDEO SECURITY DETAILS
E-801 THUMB VIDEO SECURITY DETAILS
E-802 THUMB CAMERA CONNECTIVITY - PERIMETER
COVER
C om m te ch
D es ig n
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a t r
TC102 THUMB DATA CABLING AND SECURITY MOUNTING DETAILS
TC103 THUMB SECURITY MOUNTING DETAILS
TC104 THUMB NEW CAMERA ON POLE CONNECTIVITY & SURGE PROTECTION DETAILS
TC105 THUMB FIBER BACKBONE CONNECTIVITY
TC106 THUMB RACK LAYOUTS
TC107 THUMB RACK LAYOUTS
TC108 THUMB RACK LAYOUTS
TC109 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC110 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC111 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC112 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC113 THUMB SECURITY CAMERA ONE LINE DIAGRAMS
TC114 THUMB SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER
TC115 THUMB SECURITY CAMERA ONE LINE DIAGRAMS - PERIMETER
TC201 THUMB 100 ADMINISTRATION - FIRST & SECOND FLOORS - EXISTING
TC202A THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA A - EXISTING
TC202B THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA B - EXISTING
TC202C THUMB 200 SUPPORT SERVICES - SECOND FLOOR - AREA A - EXISTING
TC203A THUMB 300 EDUCATION - BASEMENT & FIRST FLOOR - EXISTING
TC203B THUMB 300 EDUCATION - SECOND FLOOR - EXISTING
TC204 THUMB 600 LAUNDRY & 800 GENERATOR ALL FLOORS - EXISTING
TC205A THUMB HOUSING UNIT 700 AUBURN - ALL LEVELS - EXISTING
TC205B THUMB HOUSING UNIT 700 BURNS - ALL LEVELS - EXISTING
TC206A THUMB HOUSING UNIT 400 DURANT - ALL LEVELS - EXISTING
TC206B THUMB HOUSING UNIT 400 CORD - ALL LEVELS - EXISTING
TC207 THUMB HOUSING UNIT 500 ESSEX - ALL LEVELS - EXISTING
TC208A THUMB HOUSING UNIT FRANKLIN - FIRST FLOOR - EXISTING
TC208B THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR - EXISTING
TC209 THUMB CORRECTIONAL FACILITY SITE PLAN - EXISTING
TC301 THUMB 100 ADMINISTRATION - FIRST & SECOND FLOORS - NEW & REPLACE
TC302A THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA A - NEW & REPLACE
TC302B THUMB 200 SUPPORT SERVICES - FIRST FLOOR - AREA B - NEW & REPLACE
TC302C THUMB 200 SUPPORT SERVICES - SECOND FLOOR - AREA C - NEW & REPLACE
TC303A THUMB 300 EDUCATION BUILDING - FIRST FLOOR - NEW & REPLACE
TC303B THUMB 300 EDUCATION BUILDING - SECOND FLOOR - NEW & REPLACE
TC304 THUMB 600 LAUNDRY & 800 GENERATOR ALL FLOORS - NEW & REPLACE
TC305A THUMB HOUSING UNIT 700 AUBURN - ALL LEVELS - NEW & REPLACE
TC305B THUMB HOUSING UNIT 700 BURNS - ALL LEVELS - NEW & REPLACE
TC306A THUMB HOUSING UNIT 400 DURANT - ALL LEVELS - NEW & REPLACE
TC306B THUMB HOUSING UNIT 400 CORD - ALL LEVELS - NEW & REPLACE
TC307 THUMB HOUSING UNIT 500 ESSEX - ALL LEVELS - NEW & REPLACE
TC308 THUMB HOUSING UNIT FRANKLIN - FIRST FLOOR - NEW & REPLACE
TC308 THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR - NEW & REPLACE
TC309 THUMB CORRECTIONAL FACILITY SITE PLAN - NEW & REPLACE
STATE OF MICHIGAN
THUMB CORRECTIONAL FACILITY
VIDEO MANAGEMENT SYSTEM UPGRADE -PHASE 1
THUMB CORRECTIONAL FACILITY
FILE NUMBER: 472/21303.JBB
3225 John Conley Drive Lapeer, MI 48446
ELECTRICAL ENGINEER
MATRIX CONSULTING ENGINEERS, INC.
1601 EAST GRAND RIVER
LANSING, MI 48906
(517) 487-2511
SECURITY DESIGN
COMMTECH DESIGN
6581 BELDING RD. NE, SUITE 101
ROCKFORD, MI 49341
(616) 863-8132
SECURITY DRAWING INDEXELECTRICAL DRAWING INDEX
THUMB CORRECTIONAL FACILITY
3225 John Conley Drive Lapeer, MI 48446
DRAWING LIST:
E-100 THUMB ELECTRICAL ABBREVIATIONS, SYMBOLS, AND NOTES
E-200 THUMB - SITE PLAN - DEMO
E-201 THUMB - SITE PLAN - NEW
E-501 THUMB 100 ADMIN BUILDING - FIRST FLOOR PLAN - NEW
E-502 THUMB 100 ADMIN BUILDING - SECOND FLOOR PLAN - NEW
E-503 THUMB 200 SUPPORT SERVICES - FIRST FLOOR PLAN - NEW
E-504 THUMB 200 SUPPORT SERVICES - SECOND FLOOR PLAN - NEW
E-505 THUMB 300 EDUCATION - FIRST FLOOR PLAN - NEW
E-506 THUMB 300 EDUCATION - SECOND FLOOR PLAN - NEW
E-507 THUMB 600 LAUNDRY BUILDING - FIRST FLOOR PLAN - NEW
E-508 THUMB HOUSING UNIT 700 AUBURN - UPPER LEVEL FLOOR PLAN - NEW
E-509 THUMB HOUSING UNIT 700 BURNS - UPPER LEVEL FLOOR PLAN - NEW
E-510 THUMB HOUSING UNIT 400 CORD - UPPER LEVEL FLOOR PLAN - NEW
E-511 THUMB HOUSING UNIT 400 DURANT - UPPER LEVEL FLOOR PLAN - NEW
E-512 THUMB HOUSING UNIT 500 ESSEX - UPPER LEVEL FLOOR PLAN - NEW
E-513 THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR PLAN - NEW
E-800 THUMB VIDEO SECURITY DETAILS
E-801 THUMB VIDEO SECURITY DETAILS
E-802 THUMB CAMERA CONNECTIVITY - PERIMETER
COVER
C om m te ch
D es ig n
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr
TVSS
VFD
TRANSIENT VOLTAGE SURGE SUPPRESSION
VARIABLE FREQUENCY DRIVEDUPLEX RECEPTACLE
TELEPHONE / DATA OUTLET
ELECTRICAL SYMBOLS LEGEND
J
SINGLE RECEPTACLE (120 VOLT)
EMERGENCY RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
FLUSH FLOOR BOX
SURFACE FLOOR BOX
SPECIAL EQUIPMENT RECEPTACLE
TELEPHONE OUTLET
DATA OUTLET
POWER POLE
JUNCTION BOX
WALL JUNCTION BOX
PULL (JUNCTION) BOX
UNDERFLOOR JUNCTION BOX
OUTLETS CIRCUITRY and RACEWAYS
UNDERFLOOR DUCT
BUS DUCT
PLUGMOLD AS SPECIFIED
WIREMOLD AS SPECIFIED
FLEXIBLE PIGTAILS/CONNECTIONS
"CONDUIT RUN CONTINUES" INDICATION
END OF CONDUIT RUN, CAP AND STAKE
END OF CONDUIT RUN
HOME RUN (with circuit numbers)
CONDUIT STUB DOWN
CONDUIT STUB UP
CONDUIT INSTALLED
CONDUIT INSTALLED
SERVICE and EQUIPMENT
CAPACITOR
ENCLOSED CIRCUIT BREAKER
TRANSFER SWITCH
WIREWAY
GROUND CONNECTION PER N.E.C.
TELEPHONE TERMINAL BOARD
GENERATOR, KW SHOWN
CURRENT TRANSFORMERS
UTILITY METER, AS REQUIRED
WEATHERHEAD
PANELBOARD, FLUSH MOUNTED
PANELBOARD, SURFACE MOUNTED
COMB. STARTER
MAGNETIC STARTER
DISCONNECT SWITCH
TRANSFORMER
(by E.C.)
(by others)
TT
G
WW
CT
TS
T
1,3
OR
PM
WM
BD
UFD
F S
J
J
PP
J
CEILING MOUNTED WIFI
DIGITAL EQUIPMENT METER, AS REQUIRED
POLE
PUMP
PANEL
P
PNL
PVC
PRV-
P-
PB
POLY VINYL CLORIDE
POWER ROOF VENTILATOR
PULL BOX
GENERAL CONTRACTOR
GROUND
HUMIDIFIERH-
GND
GFI
GC
GROUND FAULT INTERUPTER
ABBREVIATIONS LEGEND
POWER
SWITCH
RECEPT
SF-
SWBD
TCC
SPEC
SW
RGC
RTU-
PWR
VOLTS
WATTS
UF
V
W
UL
VL
UNO
UH-
TS
TYP
TR
ROOF TOP UNIT
RECEPTACLE
SWITCHBOARD
UNDER FLOOR
SPECIFICATIONS
RIGID GALVANIZED STEEL CONDUIT
UNLESS NOTED OTHERWISE
UNDERWRITERS' LABORATORIES, INC.
TAMPER PROOF RECEPTACLE
TAMPER PROOF SWITCH
TEMPERATURE CONTROL CONTRACTOR
VERIFY LOCATION WITH OWNER
TYPICAL
UNIT HEATER
SUPPLY FAN
WITH
WITHOUT
W/
XFMR
W/O
WP
TRANSFORMER
WEATHER PROOF
HOUR
LIGHT
JUNCTION BOX
LIGHT CONTROL
ISOLATED GROUND
HORSEPOWER
MINIMUM
MOUNT
MAKE-UP AIR UNIT
MOTOR CONTROL CENTER
MAIN LUG ONLY
MOUNTED
MOUNTING
MAXIMUM
LIGHTING
LT FLEX
MTD
MUAU-
MTG
MLO
MIN
MT
MC
MAX
MCC
LTG
IG
LC
LT
IMC
JB
HR
HVAC
HOA
HP
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
NIGHT LIGHTNL
NTS
NO
NIC
NC
HAND-OFF-AUTO SELECTOR SWITCH
HEATING/VENTILATING/AIR CONDITIONING
INTERMEDIATE METAL CONDUIT
LIQUID TIGHT FLEXIBLE METAL CONDUIT
MECHANICAL CONTRACTOR
HID HIGH INTENSITY DISCHARGE
A
AC
AFF
ACU-
AHJ
AHU-
AS
B-
BC
AIC
ATS
BLDG
CHLR-
CND (C)
CKT BKR
CKT
CUH-
CU-
DISC
DFU-
EF-
EC
DWH-
EBB-
DWG
CT-
EXIST (E)
EWC
FLEX
FLA
FLR
FSES
FLUOR
EMT
ABOVE FINISHED FLOOR
AIR CONDITIONING UNIT
AMPS
ABOVE COUNTER
AIR HANDLING UNIT
AUTOMATIC TRANSFER SWITCH
AMPS INTERUPTING CAPACITY
AUTHORITY HAVING JURISDICTION
ABOVE SHELF
BOILER
BUILDING
BELOW COUNTER
CHILLER
DOMESTIC WATER HEATER
CABINET UNIT HEATER
CIRCUIT
CIRCUIT BREAKER
CONDUIT
CONDENSING UNIT
COOLING TOWER
DUCT FURNACE
DRAWING
DISCONNECT
FOOD SERVICE EQUIP. SUPPLIER
ELECTRIC WATER COOLER
ELECTRICAL CONTRACTOR
ELECTRIC BASEBOARD
ELECTRICAL METALLIC TUBING
EXISTING
EXHAUST FAN
FLOOR
FLUORESCENT
FLEXIBLE CONDUIT
FULL LOAD AMPS
EM EMERGENCY
F/S FIRE/SMOKE
FU- FURNACE
GENERAL ELECTRICAL NOTES
1. ALL NON-FIRE RATED WALLS ARE TO BE PATCHED WITH LIKE
MATERIAL TO MAINTAIN ORIGINAL RATING.
2. ALL WALL AND FLOOR PENETRATIONS THROUGH FIRE RATED WALLS
ARE TO BE SEALED WITH FIRE CAULK TO MAINTAIN ORIGINAL RATING.
3. ALL CONDUITS SHALL BE FIELD ROUTED ALONG EXISTING PIPING
AND STRUCTURAL STEEL.
4. CONTRACTORS SHALL VISIT THE PROJECT SITE DURING PRE-BID
WALK THROUGH TO DETERMINE THE EXACT EXTENT OF THE
DEMOLITION WORK REQUIRED BEFORE BIDDING THE PROJECT.
5. REMOVE ALL EXISTING OBSOLETE EXPOSED CONDUIT, WIRE AND
UNUSED EQUIPMENT WHERE WORK IS BEING DONE EXCEPT ITEMS
NOTED OTHERWISE.
6. WHERE BUILDING SURFACES ARE DAMAGED BY THE REMOVAL OF
OLD WORK, SURFACES SHALL BE PATCHED TO MATCH ADJACENT.
7. EXISTING WORK WHICH IS PRESENTLY CONCEALED AND WHICH WILL
REMAIN CONCEALED AND DOES NOT INTERFERE WITH ANY NEW
WORK OF ANY TRADE NEED NOT BE REMOVED. HOWEVER, ALL
CONDUIT SHALL BE CAPPED BELOW FINISH SURFACE AND THEN
PATCHED AND PAINTED TO MATCH, OR AS NOTED.
8. EXISTING OPENINGS, WHICH ARE TO BE REUSED, SHALL BE
MODIFIED OR ENLARGED TO SUIT THE NEW SYSTEMS AS REQUIRED.
PROVIDE ALL REQUIRED CUTTING AND PATCHING.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING THE EXISTING
WALLS TO MATCH THE ADJACENT SURFACES BEHIND ALL SURFACE
MOUNTED EQUIPMENT.
10. CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT AND LOADS
PRIOR TO INSTALLING SERVICE TO EQUIPMENT.
11. DRAWINGS ARE BASED ON EXISTING RECORD DOCUMENT AND
CASUAL FIELD OBSERVATION. REPORT ANY DISCREPANCIES TO
ENGINEER FOR CLARIFICATION.
12. MINIMUM RACEWAY SIZE; 3/4" TRADE SIZE. REFER TO SPECIFICATION
260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS.
13. ALL CONDUIT ABOVE 10 FOOT SHALL MEET THE FOLLOWING
REQUIREMENTS:
13.1. STRAP DISTANCE: 5 FEET.
13.1.1. FASTENERS: 2 HOLE WITH SECURITY SCREWS.
13.1.2. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED-
GRC.
13.1.3. FITTINGS: COMPRESSION.
13.1.4. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND
ENCLOSURES.
14. ALL CONDUIT BELOW 10 FOOT SHALL MEET THE FOLLOWING
REQUIREMENTS:
14.1. STRAP DISTANCE: 3 FEET.
14.2. FASTENERS: 2 HOLE WITH SECURITY SCREWS.
14.3. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED -
GRC.
14.4. FITTINGS: COMPRESSION.
14.5. BELL BOXES: FS TYPE.
14.6. NO KNOCKOUTS.
14.7. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND
ENCLOSURES
15. ALL EXPOSED WIRING SHALL BE IN CONDUIT. OPEN LOW VOLTAGE
WIRING ABOVE CEILINGS IS ACCEPTABLE.
16. CONDUITS SHALL BE INSTALLED STRAIGHT AND LEVEL AND SHALL BE
PARALLEL OR PERPENDICULAR TO THE BUILDING LINES.
17. CONTRACTOR SHALL VERIFY ALL VOLTAGES BEFORE CONNECTING
ANY EQUIPMENT.
18. ALL LOCATIONS WHERE THE WALLS CAN'T BE FISHED SHALL BE
SURFACE MOUNTED CONDUIT FOLLOWING NOTES 11 AND 12 ABOVE.
19. ALL WALLS THAT ARE ACCESSIBLE SHALL BE FISHED AND DEVICE
CUT INTO WALL.
20. ALL EXTERIOR CONCEALED CONDUIT UNDERGROUND SHALL BE RNC,
TYPE EPC-40-PVC
21. ANY ELECTRICAL OUTAGE SHALL NOT LAST OVER 2-HOURS. FOR
OUTAGES OVER PORTABLE GENERATORS SHALL BE USED TO
REPLACE ANY ELECTRICAL SERVICE EXCEEDING THAT DURATION.
22. UPON RELOCATING LIGHTS AND CAMERAS CONTRACTOR SHALL
VERIFY THAT THE LIGHTS AND CAMERAS ARE WORKING PROPERLY
PRIOR TO LEAVING THE SITE.
23. CONTRACTOR SHALL PROVIDE AND INSTALL ALL REQUIRED
COMPONENTS, RACEWAYS, WIRE, AND HARDWARE, AS INDICATED ON
DRAWINGS.
24. ALL WORK DONE WITHOUT APPROVED SHOP DRAWINGS IS AT
CONTRACTORS RISK.
25. CONTRACTOR SHALL USE MDOC APPROVED POLES AND FIXTURES,
NOT ALTERNATES WILL BE ALLOWED. ALL OTHER STATE OF
MICHIGAN AGENCY SPECIFICATIONS DO NOT APPLY.
SSCP
CCTV CONTROL PANELCCTV
SECURITY SYSTEM CONTROL PANEL
CAMERA
SOUND and SIGNAL
C
TYPICAL RACK MOUNTED 1500VA UPS- EQUIPMENT SPECIFICATION
1500VA UNINTERRUPTIBLE POWER SUPPLY (UPS)
PROVIDE RACK-MOUNTABLE, UNINTERRUPTIBLE POWER SUPPLY (UPS).
UPS SHALL BE 1.5KVA RATED, HIGH EFFICIENCY, DOUBLE CONVERSION,
CONTINUOUS DUTY, ON-LINE TYPE. INPUT VOLTAGE OF 120VAC, 60HZ,
1-PHASE, 3-WIRE PLUS GROUND. OUTPUT VOLTAGE OF 120VAC, 60HZ,
1-PHASE, 3-WIRE PLUS GROUND. 65KAIC RATED. INTEGRATED
MAINTENANCE BYPASS SWITCH, BACKLIT LCD CONTROL PANEL. INCLUDE
WEB CARD AND ALARM RELAY BOARD FOR REMOTE MONITORING,
INDOOR RATED IP-20 ENCLOSURE. ENERGY SEALED CELL BATTERIES.
5-MINUTE RUN TIME. SELF DIAGNOSTICS. HARD-WIRED TERMINALS FOR
CONNECTION TO EXTERNAL 120VAC, 1PH POWER PANEL.
LIEBERT GXT5-15000
INSTALLER PROVIDED INPUT AND OUTPUT CABLING SHALL BE FLEXIBLE
CONDUIT TO ALLOW UPS POD BYPASS MODULE WITHOUT POWERING
DOWN THE LOAD.
INCLUDE SYSTEM START-UP SERVICES, USER TRAINING AND TWO-YEAR,
ON-SITE WARRANTY SERVICE FOR PARTS & LABOR.
SEQUENCE OF EQUIPMENT INSTALL:
1. INSTALL NEW 1500VA UPS ON RACK.
2. RELOCATE CAMERA EQUIPMENT POWER TO NEW UPS.
3. REMOVE OLD UPS.
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-100
JKB
JFS
ELECTRICAL ABBREVIATIONS,
SYMBOLS, AND SCHEDULES
CB
CB
CB
CB
CB
CB
CB
CB
F28
F29
F30
F31
F32
F33
F35
F36
F37
F38
F39
F44
F43
F42
F41
F40
F27
F26
F25
F24
F23
F22
F21
F20
F19
F18
F17
F16
F15
F14 F13F12F11F10
F9
F8F7
F6
F5F4
F3
F2
F1
33333
P6
P11
P7 P5
P12
P8
P4
P9
P13
P14
P19
P10
P16
P20
P17
P22
P21
P25
P23
P24
P26
P27
4 4 4 4 4
4 4 4 4 4
F34
LAUNDRY
SHEET E-507
FRANKLIN
SHEET E-513
ESSEX
SHEET E-512
EDUCATION
SHEET E-505
SHEET E-506
SUPPORT SERVICES
SHEET E-503
SHEET E-504
ADMINISTRATIVE
SHEET E-501
SHEET E-502
ABURN
SHEET E-508
BURNS
SHEET E-509
DURANT
SHEET E-511
CORD
SHEET E-510
EXISTING EQUIPMENT TO REMAIN.
EXISTING CAMERA TO BE REMOVED AND REPLACED.
REMOVE LIGHT HEAD(S) FROM POLE.
REMOVE LIGHT POLE, EXISTING BASE TO REMAIN.
DEMOLITION NOTES
1. CONTRACTOR SHALL DISCONNECT EXISTING LIGHTS AND CAMERAS
AND RELOCATE ANY EXISTING SIGNS TO NEW POLE.
2. CONTRACTOR SHALL VERIFY ALL EXISTING ANCHOR BOLTS, BOLT
PATTERNS, QUANTITIES, SIZES, BOLT PATTERNS FOR LIGHT
FIXTURES AND CAMERAS, ON EACH POLE BASE BEING REPLACED.
3. NO LIGHTS AND CAMERAS SHALL BE OUT OVER NIGHT.
4. ALL EXISTING CONCRETE POLE BASES TO REMAIN.
GENERAL ELECTRICAL NOTES
2 2
2 2 2
2 2
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-200
JKB
JFS
SITE PLAN- DEMO
N ELECTRICAL - SITE PLAN - DEMO
SCALE: 1" = 40'-0"
100 5 20 40 80 100
LAUNDRY
SHEET E-507
FRANKLIN
SHEET E-513
ESSEX
SHEET E-512
EDUCATION
SHEET E-505
SHEET E-506
SUPPORT SERVICES
SHEET E-503
SHEET E-504
ADMINISTRATIVE
SHEET E-501
SHEET E-502
ABURN
SHEET E-508
BURNS
SHEET E-509
DURANT
SHEET E-511
CORD
SHEET E-510
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA LA LA LA LA LA LA LA
LA LA LA LA LA LA
LA LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LALA
LA
LA
LA
LA
LA
LA
LA
LA
LA
LA
F28
F29
F30
F31
F32
F33
F35
F36
F37
F38
F39
F44
F43
F42
F41
F40
F27
F26
F25
F24
F23
F22
F21
F20
F19
F18
F17
F16
F15
F14
F13F12F11
F10
F9
F8F7
F6 F5F4
F3
F2
F1
CB
CB
CB
CB
CB
CB
CB
CB
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EXEX
EX
EX
EX
EX
1 1
1 1
1 1 1 1
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
LB
P6
P11
P7
P5
P12
P8
P4
P9
P13
P14
P19 P10
P16
P20
P17
P22
P21
P25
P23
P24
P26
P27
LED FLOODLIGHT LUMINAIRE WITH DIE-CAST ALUMINUM HOUSING,
BRONZE FINISH, ADJUSTABLE ARM TENON-MOUNT SLIP-FIT BRACKET,
5000/5700K COLOR TEMPERATURE, 6X6 OR 60-DEGREE FLOOD OPTICS.
FIXTURE
MOUNTING
HEIGHT
LAMPSDESCRIPTION AND COMMENTSTYPE
LA
MANUFACTURER CATALOG NO.
LIGHTING FIXTURE SCHEDULE
40 FEET
26500 LUMINS
5000/5700K
LED
OSQ-A-NM-60D-U-57K-UH-BZ
PMLED-5-5K-10A-AH-66-1-K-ZP
NFFLED-L-C75-7050-66-S-BZ
CREE
HOLOPHANE
LUMARK
BALLAST INFO
NON DIMMING
347-480VAC
FIELD VERIFY VOLTAGE
BEFORE ORDERING
LIGHT POLE HEADLB 40 FEET
15000 LUMINS
4000K
LED
OSQ-M-B-16L-57K7-5M-UH-NM-BZCREE
NON DIMMING
347-480VAC
FIELD VERIFY VOLTAGE
BEFORE ORDERING
2 2 2 2 2
2 2 2 2
F34
EX
3 3
3 3
ELECTRICAL KEY NOTES
PROVIDE AND INSTALL NEW LED LIGHT FIXTURES ONE FOR
ONE ON POLE.
PROVIDE AND INSTALL NEW POLE.
PROVIDE AND INSTALL SURGE PROTECTION DEVICES AND
JUNCTION BOXES TO CAMERA ON POLE.
PROVIDE AND INSTALL SURGE PROTECTION DEVICES IN
ATTIC TO CAMERA ON BUILDING.
GENERAL NEW LIGHTING NOTES
1. CONTRACTOR SHALL DISCONNECT EXISTING LIGHTS
AND RELOCATE EXISTING SIGNS AND CAMERAS TO NEW
POLES AS APPLICABLE.
2. CONTRACTOR SHALL AIM LIGHT HEADS AFTER DARK
WHILE ENGINEER TAKES LIGHT READINGS TO ACHIEVE
OPTIMAL PHOTMETRICS.
3. DURING REINSTALL OF CAMERAS, CONTRACTOR SHALL
AIM CAMERAS PER OWNERS DIRECTION FROM CENTRAL
CONTROL. CONTRACTOR SHALL OBTAIN SIGN-OFF OF
AIMING.
4. NO LIGHTS AND CAMERAS SHALL BE OUT OVER NIGHT.
LB
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-201
JKB
JFS
SITE PLAN- NEW
N ELECTRICAL - SITE PLAN - NEW
SCALE: 1" = 40'-0"
100 5 20 40 80 100
ELECTRICAL KEY NOTES
RE-FEED EXISTING RECEPTACLE FROM UPS PANEL ON
SECOND FLOOR TO SUPPLY POWER TO COMPUTER TOWERS
AND MONITORS.
PROVIDE AND INSTALL 120V DUPLEX RECEPTACLE FROM UPS
PANEL ON SECOND FLOOR TO SUPPLY POWER TO
COMPUTER TOWERS AND MONITORS.
72"AFF
1 1 1 1 1
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-501
JKB
JFS
ELECTRICAL - ADMIN
BUILDING - 1ST FLOOR
N ELECTRICAL - 100 ADMIN BUILDING 1ST FLOOR PLAN - POWER - NEW
SCALE: 1/8" = 1'-0"
0 1 5 10 20
PROVIDE AND INSTALL BREAKERS AS NEEDED FOR NEW UPS
CIRCUITS.
RE-FEED EXISTING RECEPTACLES FROM UPS SUB PANEL.
PROVIDE AND INSTALL NEW 120V RECEPTACLES FED FROM
UPS SUB PANEL. PROVIDE NEW BREAKERS AS REQUIRED.
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK
EXISTING
20KVA UPS
EXISTING
20KVA
XFMR
EXISTING
UPS PANEL
120/208V, 3Ø
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK
2 2 2 2
3 3
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-502
JKB
JFS
ELECTRICAL - ADMIN
BUILDING - 2ND FLOOR
N THUMB ADMINISTRATION- 2ND FLOOR PLAN - NEW
MATCH LINE "A"
MATCH LINE "B"
MATCH LINE "A"
MATCH LINE "B"
MATCH LINE "A"
MATCH LINE "B"
MATCH LINE "A"
MATCH LINE "B"
ELECTRICAL KEY NOTES
REPLACE EXISTING UPS WITH NEW 1500VA UPS.1
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-503
JKB
JFS
ELECTRICAL - SUPPORT
SERVICES - 2ND FLOOR
N THUMB 200 SUPPORT SERVICES - 1ST FLOOR PLAN - NEW
REPLACE EXISTING UPS WITH NEW 1500VA UPS.
PROVIDE AND INSTALL NEW 120V DUPLEX RECEPTACLE TO
PROVIDE POWER FOR UPS.
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-504
JKB
JFS
ELECTRICAL - SUPPORT
SERVICES - 2ND FLOOR
N THUMB 200 SUPPORT SERVICES - 2ND FLOOR PLAN - NEW
REPLACE EXISTING UPS WITH NEW 1500VA UPS.1
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-505
JKB
JFS
ELECTRICAL - EDUCATION
BUILDING - 1ST FLOOR
N THUMB 300 EDUCATION - 1ST FLOOR PLAN - NEW
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-506
JKB
JFS
ELECTRICAL - EDUCATION
BUILDING - 2ND FLOOR
N THUMB 300 EDUCATION - 2ND FLOOR PLAN - NEW
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-507
JKB
JFS
ELECTRICAL - LAUNDRY
BUILDING - 1ST FLOOR
N THUMB 600 LAUNDRY - 1ST FLOOR PLAN - NEW
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-508
JKB
JFS
ELECTRICAL - HOUSING UNIT
AUBURN - UPPER
N ELECTRICAL - HOUSING UNIT AUBURN UPPER LEVEL FLOOR PLAN - POWER - NEW
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-509
JKB
JFS
ELECTRICAL - HOUSING UNIT
BURNS- UPPER
N THUMB HOUSING UNIT 700 BURNS - UPPER LEVEL FLOOR PLAN - NEW
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-510
JKB
JFS
ELECTRICAL - HOUSING UNIT
CORD - UPPER
N THUMB HOUSING UNIT 400 CORD - UPPER LEVEL FLOOR PLAN - NEW
REPLACE EXISTING UPS WITH NEW 1500VA UPS..1
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-511
JKB
JFS
ELECTRICAL - HOUSING UNIT
DURANT - UPPER
N THUMB HOUSING UNIT 400 DURANT - UPPER LEVEL FLOOR PLAN - NEW
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-512
JKB
JFS
ELECTRICAL - HOUSING UNIT
ESSEX - UPPER
N THUMB HOUSING UNIT 500 ESSEX - UPPER LEVEL FLOOR PLAN - NEW
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-513
JKB
JFS
ELECTRICAL - HOUSING UNIT
FRANKLIN - UPPER
N THUMB HOUSING UNIT FRANKLIN - SECOND FLOOR PLAN - NEW
CAMERA JUNCTION BOX INSTALLATION DETAIL
SCALE: N.T.S.
#10 AWG
#10 AWG
#10 AWG
#10 AWG
ETHERNET SWITCH
CABINET
LIGHTING ARRESTORS
ELECTRICAL EQUIPMENT
TYPICAL FOR
EACH PIECE OF
EQUIPMENT
CONNECT TO GROUND BAR
#10 AWG
TELECOMMUNICATIONS
GROUND BAR
GROUND BAR TYPICAL
TYPICAL CRIMP LUG CONNECTIVITY
1. ALL GROUNDING CONNECTIONS SHALL BE ROUTED TO CLOSEST
GROUND BAR.
2. GROUND BAR WILL BE PROVIDED WITH THE CABINET AND WILL BE
CONNECTED TO THE EARTH, ELECTRICAL GROUNDING SYSTEM,
AND POLE.
3. ALL BONDING CONNECTIONS SHALL BE MAKE WITH TWO HOLE
CRIMP LUGS ONLY AT THE GROUND BAR.
4. FROND CONNECTIONS SHALL BE MAKE WITH A MINIMUM OF #10
AWG CABLE.
5. ALL GROUND WIRES SHALL HAVE GREEN INSULATION.
GROUNDING NOTES
COMMUNICATIONS GROUNDING DETAIL
SCALE: N.T.S.
K K
EXISTING POWER
STRIP FED FROM
UPS.
EXISTING SURGE
SUPPRESSORS, LIGHTING
ARRESTORS.
EXISTING POE INJECTORS.
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX.
TERMINATE ALL NEW CABLES
HERE FOR TESTING.
EXISTING TYPICAL
COMMUNICATION CONDUITS TO
LIGHT POLES AND OTHER
CABINETS.
EXISTING GROUND BAR.
EXISTING CAT 6 CABLES TO
CAMERAS.
EXISTING CAT 6 CABLES TO
CAMERAS.
EXISTING CAT 6 CABLES TO
CAMERAS.
EXISTING 2'X2'
FIREPROOF PLYWOOD
WALL FIELD.
NEW CAT 6 CABLES TO
CAMERAS.
NEW CAT 6 CABLES TO
CAMERAS.
EXISTING CAT 6 CABLES TO
CAMERAS.
NEW CAT 6 CABLES TO
CAMERAS.
NEW CAT 6 CABLES TO
CAMERAS.
EXISTING CAT-6
PATCH CABLES
ADD D-RINGS WHERE
NECCESARY.
WALL FIELD BUILD-OUT FOR CAMERAS ON POLES FED FROM BUILDINGS DETAIL
SCALE: N.T.S.
CAT-6 CABLE TO
COMMUNICATIONS
ROOM.
15" DATA SERVICE LOOP.
SUPPORT TO STRUCTURE.
EXTERIOR CAMERA
MOUNTED TO BUILDING
WALL.
NEW CAT-6 PATCH CABLE.
SURGE PROTECTION
DEVICE.
EXTERIOR CAMERA CABLING DETAIL
SCALE: N.T.S.
2 K
EXISTING MOUNTING POLE
EXISTING TYPICAL
COMMUNICATIONS
CONDUITS TO LIGHT
POLES AND OTHER
CABINETS.
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX. TERMINATE
ALL NEW CABLES HERE FOR
TESTING.
EXISTING MODULAR JACKS
IN SURFACE MOUNT BOX.
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX.
TERMINATE ALL NEW CABLES
HERE FOR TESTING.
EXISTING MODULAR JACKS
IN SURFACE MOUNT BOX.
EXISTING MODULAR JACKS
IN SURFACE MOUNT BOX.
EXISTING MOUNTING POLE
SURGE PROTECTION DEVICES,
LIGHTING ARRESTORS.
EXISTING POE INJECTORS
EXISTING POWER
SUPPLY FOR
ETHERNET
SWITCH- TO
REMAIN
EXISTING
ETHERNET
SWITCH
FUTURE
SWITCH
EXISTING POWER
SUPPLY FOR
ETHERNET
SWITCH- FUTURE
EXISTING FIBER OPTIC
PATCH PANEL
RESERVED FOR ELECTRICAL
EXISTING PLUG STRIP-
EXISTING
EXISTING GROUND BAR-
EXISTING
NETWORK CABINET DETAIL - TYPICAL FOR PERIMETER CABINETS
SCALE: N.T.S.
GRADE
EXISTING
CONDUITS.
CAMERA MOUNTED ON POLE DETAIL
SCALE: N.T.S.
EXISTING REBAR
CAGES.
EXISTING ANCHOR BOLTS
BOLT PATTERN FIELD
VERIFY PATTERN
EXISTING
GROUT UNDER POLE BASE
EXISTING
GROUND ROD
EXISTING
CADWELD
HANDHOLE
EXISTING FIXED CAMERA
MOUNTING HEIGHT
EXISTING
1" TYPE C
JUNCTION BOX
16' AFG MINIMUM
OR 2' ABOVE
RAZORWIRE
MINIMUM
EXISTING JUNCTION
BOX
EXISTING
1" PVC (CAMERA CABLE) FROM
CABINET
EXISTING
FLEXIBLE, WATER-PROOF
RUBBER COUPLING.
EXISTING
1" RGS LOW VOLTAGE
CONDUIT
EXISTING
CONCRETE BASE OR
PRECAST BASE.
EXISTING POLE
22' AFG
MINIMUM
EXISTING PTZ CAMERA
MOUNTING HEIGHT
TO UPS.
TO POWER SOURCE
ELECTRICAL KEY NOTES
RE-TERMINATE EXISTING CAT 6 CABLE FROM CAMERA HEAD AT SURGE
PROTECTION DEVICE. PROVIDE AND INSTALL NEW CAT 6 CABLE FROM SURGE
PROTECTION DEVICE TO CAMERA HEAD.
NEW 1" CONDUIT TO CAMERA
EXISTING 1" CONDUIT TO
CABINET
NEW SURGE
SUPPRESSOR
RAYCAP NJ2010B
EXISTING 8"W X 8"H X 4"D
ENCLOSURE, NEMA 4, HINGED
JUNCTION BOX. HOFFMAN
A808CHNF WITH A8P8G PANEL
OR EQUAL.
PROVIDE WITH PAD
LOCKABLE HASP
STAINLESS
STEEL PIPE
STRAP, TYP.
STEEL
CHANNEL,
UNISTRUT OR
EQ.
EXISTING #6 COPPER
GROUND WIRE IN 3/4" PVC
CONDUIT TO 3/4" X 8' GROUND
ROD AND POLE.
POLE
EXISTING CONNECT
GROUND WIRE TO
GROUND BAR.
JUMPER TO TSS WITH #12G.
SIDE VIEWFRONT VIEW
TSS EXISTING 1"x3"x1/4" TK.
COPPER GROUND BAR.
NEW 1" CONDUIT
NEW BACK BOX
8 NEW POLE BASE WITHOUT CAMERA DETAIL
SCALE:NTS
GRADE
GROUND WIRE
COORDINATE WITH EXISTING POLE
MANUFACTURER FOR ANCHOR BOLTS (4)
AND BOLT PATTERN.
POLE
PROVIDE 6'-6" DEEP 24" DIAM.
CONCRETE BASE
POURED IN PLACE OR
PRECAST CONCRETE
FOUNDATION
PROVIDE #4 REBAR CAGES
IN EACH FOUNDATION.
SECTION
6'-6"
MATCH
EXISTING
STEEL POLE.
1" RGS CONDUIT SURFACE MOUNTED ON
STEEL POLE. FOR CAMERA CABLES
COORDINATE WITH COMMTECH DESIGN.
HANDHOLE
1" PVC (CAMERA CABLE)
FROM CABINET
NEW 1" RGS LOW
VOLTAGE CONDUIT
SPLICE NEW CONDUCTORS TO MAIN LIGHTING
CONDUCTORS IN EXISTING HANDHOLE. PROVIDE
FUSING PER MANUFACTURER.
CAMERA
NEW 1" TYPE C
JUNCTION BOX
18'
NEMA 4
JUNCTION BOX
GRADE
FROM NEXT POLE TO NEXT POLE
EXISTING
LIGHTING CIRCUIT
MATCH
EXISTING
6 NEW POLE BASE WITH CAMERA DETAIL
SCALE:NTS
PROVIDE #4 REBAR CAGES
IN EACH FOUNDATION.
COORDINATE WITH EXISTING POLE
MANUFACTURER FOR ANCHOR BOLTS (4)
AND BOLT PATTERN.
SPLICE NEW CONDUCTORS TO MAIN LIGHTING
CONDUCTORS IN EXISTING HANDHOLE. PROVIDE
FUSING PER MANUFACTURER.
HANDHOLE
6'-6"
PROVIDE 6'-6" DEEP 24" DIAM.
CONCRETE BASE
POURED IN PLACE OR
PRECAST CONCRETE
FOUNDATION
SECTION
NEW EARTH
NEW EARTH
E-800
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-800
JKB
JFS
ELECTRICAL DETAILS
GRADE
EXISTING
CONDUITS.
NEW POLE DETAIL - CAMERA & LIGHT
SCALE: N.T.S.
EXISTING REBAR
CAGES.
EXISTING ANCHOR BOLTS
BOLT PATTERN FIELD
VERIFY PATTERN
EXISTING
GROUT UNDER POLE BASE
EXISTING
GROUND ROD
EXISTING
CADWELD
TYPICAL CONDUIT MOUNTING DETAIL
SCALE: N.T.S.
SQUARE POLE1" RGS CONDUIT
SQUARE POLE
STAINLESS
STEEL PIPE
STRAP.
3 REQUIRED,
MIN.
STAINLESS
STEEL
MOUNTING
BRACKET
ROUND STEEL
OR WOOD
POLE
1" RGS CONDUIT
ROUND POLE
STAINLESS
STEEL PIPE
STRAP.
3 REQUIRED,
MIN.
STAINLESS
STEEL
MOUNTING
BRACKET
POLE1" RGS CONDUIT
ANGLE POLE
STAINLESS
STEEL PIPE
STRAP.
3 REQUIRED,
MIN.
STAINLESS
STEEL
MOUNTING
BRACKET
NEW STEEL POLE WITH FACTORY FINISH
TO MATCH EXISTING POLE FINISH.
GRADE
HANDHOLE
EXISTING
CONDUITS.
EXISTING
CONCRETE BASE.
NEW POLE DETAIL - LIGHT ONLY
SCALE: N.T.S.
EXISTING REBAR.
EXISTING ANCHOR BOLTS
BOLT PATTERN FIELD
VERIFY PATTERN
SEE SHEET E-201
FOR POLE HEIGHTS
BULLHORN.
EXISTING
GROUT UNDER POLE BASE
BOLT COVER
EXISTING
GROUND ROD
EXISTING
CADWELD
BRACKET ARM SUPPLIED AND INSTALLED BY
ELECTRICAL CONTRACTOR.
NEW STEEL POLE WITH FACTORY FINISH
TO MATCH EXISTING POLE FINISH.
GRADE
HANDHOLE
NEW POLE DETAIL - ROADWAY/INTERIOR LIGHT
SCALE: N.T.S.
EXISTING ANCHOR BOLTS
BOLT PATTERN FIELD
VERIFY PATTERN
SEE SHEET E-201
FOR POLE HEIGHTS
EXISTING
GROUT UNDER POLE BASE
BOLT COVER
BRACKET ARM SUPPLIED AND INSTALLED BY
ELECTRICAL CONTRACTOR.
NEW STEEL POLE WITH FACTORY FINISH
TO MATCH EXISTING POLE FINISH.
GRADE
HANDHOLE
NEW POLE DETAIL - ROADWAY/INTERIOR TWO HEADED LIGHT
SCALE: N.T.S.
EXISTING ANCHOR BOLTS
BOLT PATTERN FIELD
VERIFY PATTERN
SEE SHEET E-201
FOR POLE HEIGHTS
EXISTING
GROUT UNDER POLE BASE
BOLT COVER
NEW STEEL POLE WITH FACTORY FINISH
TO MATCH EXISTING POLE FINISH.
NEW 1" RGS CONDUIT SURFACE MOUNTED
ON STEEL POLE. FOR CAMERA CABLES.
SEE CONDUIT MOUNTING ON POLE DETAIL 6
ON SHEET E800.
HANDHOLE
CAMERA
EXISTING
1" TYPE C
JUNCTION BOX
25'
NEMA 4
JUNCTION BOX
BULLHORNS.
BOLT COVER
EXISTING
1" PVC (CAMERA CABLE) FROM
CABINET
FLOOD LIGHTS. REFER TO SITE PLAN FOR
TYPE AND QUANTITY.
EXISTING
CONDUITS.
EXISTING
CONCRETE BASE.
EXISTING REBAR.
EXISTING
GROUND ROD
EXISTING
CADWELD
EXISTING
CONDUITS.
EXISTING
CONCRETE BASE.
EXISTING REBAR.
EXISTING
GROUND ROD
EXISTING
CADWELD
EXISTING
FLEXIBLE, WATER-PROOF
RUBBER COUPLING.
EXISTING
1" RGS LOW VOLTAGE
CONDUIT
EXISTING
CONCRETE BASE OR
PRECAST BASE.
FLOOD LIGHTS. REFER TO SITE PLAN FOR
TYPE AND QUANTITY.
LIGHTS. REFER TO SITE PLAN FOR TYPE
AND QUANTITY.
LIGHTS. REFER TO SITE PLAN FOR TYPE
AND QUANTITY.
LIGHTS. REFER TO SITE PLAN FOR TYPE
AND QUANTITY.
SEE SHEET E-201
FOR POLE HEIGHTS
BRACKET ARM SUPPLIED AND INSTALLED BY
ELECTRICAL CONTRACTOR.
NEW STEEL POLE WITH FACTORY FINISH
TO MATCH EXISTING POLE FINISH.
GRADE
HANDHOLE
NEW POLE DETAIL - ROADWAY/INTERIOR THREE HEADED LIGHT
SCALE: N.T.S.
EXISTING ANCHOR BOLTS
BOLT PATTERN FIELD
VERIFY PATTERN
SEE SHEET E-201
FOR POLE HEIGHTS
EXISTING
GROUT UNDER POLE BASE
BOLT COVER
EXISTING
CONDUITS.
EXISTING
CONCRETE BASE.
EXISTING REBAR.
EXISTING
GROUND ROD
EXISTING
CADWELD
LIGHTS. REFER TO SITE PLAN FOR TYPE
AND QUANTITY.
LIGHTS. REFER TO SITE PLAN FOR TYPE
AND QUANTITY.
BRACKET ARM SUPPLIED AND INSTALLED BY
ELECTRICAL CONTRACTOR.
NEW STEEL POLE WITH FACTORY FINISH
TO MATCH EXISTING POLE FINISH.
GRADE
HANDHOLE
NEW POLE DETAIL - ROADWAY/INTERIOR FOUR HEADED LIGHT
SCALE: N.T.S.
EXISTING ANCHOR BOLTS
BOLT PATTERN FIELD
VERIFY PATTERN
SEE SHEET E-201
FOR POLE HEIGHTS
EXISTING
GROUT UNDER POLE BASE
BOLT COVER
EXISTING
CONDUITS.
EXISTING
CONCRETE BASE.
EXISTING REBAR.
EXISTING
GROUND ROD
EXISTING
CADWELD
LIGHTS. REFER TO SITE PLAN FOR TYPE
AND QUANTITY.
LIGHTS. REFER TO SITE PLAN FOR TYPE
AND QUANTITY.
PROVIDE AND INSTALL NEW POLARIS
STYLE TERMINATIONS INSIDE POLE FOR
WIRING
PROVIDE AND INSTALL NEW POLARIS
STYLE TERMINATIONS INSIDE POLE FOR
WIRING
PROVIDE AND INSTALL NEW POLARIS
STYLE TERMINATIONS INSIDE POLE FOR
WIRING
PROVIDE AND INSTALL NEW POLARIS
STYLE TERMINATIONS INSIDE POLE FOR
WIRING
PROVIDE AND INSTALL NEW POLARIS
STYLE TERMINATIONS INSIDE POLE FOR
WIRING
PROVIDE AND INSTALL NEW POLARIS
STYLE TERMINATIONS INSIDE POLE FOR
WIRING
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-801
JKB
TYPICAL PERIMETER CAMERA CONNECTIVITY DIAGRAM
SCALE: N.T.S.
CAB-XXX
ETHERNET
SWITCH
POE
INJECTOR
SURGE
PROTECTOR
SURGE
PROTECTOR
PERIMETER CABINET
CONNECT TO GROUND
BAR #10 AWG TYP.
EXISTING CAT-6 CABLE IN
CONDUIT
NEW CAT-6 PATCH
CABLE IN CONDUIT
NEW JUNCTION BOX
EXISTING
FIXED
CAMERA
L
NA
J
J
ETHERNET SWITCH
POE POWER
INJECTOR
SURGE PROTECTION
DEVICE
SURGE PROTECTION
DEVICE
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX. TERMINATE
ALL NOW CABLES HERE FOR
TESTING.
EXISTING SHIELDED CAT-6
PATCH CABLE FROM POLE
TO CABINET.
EXISTING
CAT-6 PATCH
CABLE
NEW CAT-6
PATCH CABLE
EXISTING
GROUND CABLE
EXISTING
GROUND CABLE
EXITING
GROUND ROD
FIXED OR PTZ
CAMERA ON POLE
CAMERA CONNECTIVITY AT CABINET CAMERA CONNECTIVITY AT POLE
TYPICAL PERIMETER CAMERA CONNECTIVITY DIAGRAM
SCALE: N.T.S.
NEW 1" CONDUIT
NEW CAT-6 PATCH
CABLE IN CONDUIT
NEW JUNCTION BOX
NEW 1" CONDUIT
EXISTING
FIXED
CAMERA
C om m te ch
D es ig n
472/21303.MAA
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472TCFMaintproj consultant job no.
21316.27 sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
04/22/22 50% OWNER REVIEW
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a tr ix
06/24/22 95% OWNER REVIEW
07/15/22 BID SET
E-802
JKB
TC102
CONNECTIVITY CODE
TC101
TYPICAL PERIMETER CAMERA CABLE LABELS
AT FACEPLATE & PATCH PANEL
TC101
FIBER OPTIC CABLE AT PERIMETER CABINETS
LABELING AT PATCH PANEL
TC101
COMMUNICATIONS GROUNDING DETAIL
TC101
FIBER OPTIC PANEL
LABELING DETAIL
TC101
UTP PATCH PANEL (TYP)
TC101
TYPICAL DATA CABLE LABELING
AT FACEPLATE AND PATCH PANEL
TC101
TYPICAL FACEPLATE LABELING
COMMUNICATION CABLE SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
NETWORK EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
SECURITY EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
SECURITY SYMBOL LEGEND
SYMBOL DESCRIPTION
COMMUNICATION EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
ABBREVIATIONS
ABBREV. DESCRIPTION ABBREV. DESCRIPTION
PC
CAMERA EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO. DROP CEILING HARD
CEILING/WALL
BUILDING
EXTERIOR
BUILDING
EXTERIOR
CORNER
POLE MOUNT
LT
TC101
THUMB SECURITY
LEGENDS, DETAILS AND
SCHEDULES
C om m te ch
D es ig n
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a
TC102
SECURITY CAMERA
CONNECTIVITY CODE
TC102
SECURITY CAMERA
CONNECTIVITY CODE 2
TC102
NEW PC AND MONITOR
FOR CAMERA SYSTEM
TC102
CONNECTIVITY CODE
TC102
CONNECTIVITY CODE
TC102
NEW PC FOR CAMERA SYSTEM
REPLACE EXISTING
P2
P4
P6
P8
P1
P3
P5
100/1000 SFP
P10 Link/ActiveP9
Console
FAULT
9600.N.8.1
PWR2
PWR1
R.M.
PWR
Communication Networks
TM
www.comnet.net 203-796-5300
P7
10/100/1000T
100/1000 SFP
10/100/1000T
P9
P10
P7 P8 P5 P6 P3 P4 P1 P2
PoE
MEAN WELLDRP-240-48
SWITCHING REGULATOR
POWER FACTOR CORRECTION
INPUT: 100-240VAC 3.5A
OUTPUT: 48V 5.0A
MADE IN TAIWAN
LN-V-V+V+V
DC OK
CNGE2FE8MSPOE
P2
P4
P6
P8
P1
P3
P5
100/1000 SFP
P10 Link/ActiveP9
Console
FAULT
9600.N.8.1
PWR2
PWR1
R.M.
PWR
Communication Networks
TM
www.comnet.net 203-796-5300
P7
10/100/1000T
100/1000 SFP
10/100/1000T
P9
P10
P7 P8 P5 P6 P3 P4 P1 P2
PoE
MEAN WELLDRP-240-48
SWITCHING REGULATOR
POWER FACTOR CORRECTION
INPUT: 100-240VAC 3.5A
OUTPUT: 48V 5.0A
MADE IN TAIWAN
LN-V-V+V+V
DC OK
TC102
NETWORK CABINET DETAIL
TYPICAL FOR PERIMETER CABINETS 4
TC102
WALLFIELD BUILD-OUT FOR CAMS ON POLES
THAT ARE FED FROM A BUILDING
TC102
NEW PC FOR CAMERA SYSTEM
REPLACE EXISTING
TC102
NEW PC FOR CAMERA SYSTEM
REPLACE EXISTING
PC-MINI-NEW
PC-MINI-REP
PC-NEW
PC-REP
TC102
NEW LAPTOP FOR CAMERA SYSTEM
REPLACE EXISTING
LT-NEW
TC102
THUMB CABLING &
SECURITY MOUNTING
DETAILS
C om m te ch
D es ig n
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a
| Sheets and Views |
| TC00-Cover |
| TC101-Security |
| TC102-Security |
File details come from the government source that posted it. Updated .