472_18411_JNS - Southern Region Transportation Move to Block 5 - DRAWINGS.pdf
PDF 3 MB Posted
- Solicitation number
- RFQ-171-190000000172-2
- Issued by
- Kalamazoo County, Huntington Woods City, Michigan
About this file
These are construction drawings from the State of Michigan Department of Technology, Management and Budget Facilities and Business Services Administration for a video security and access control project at the Jackson Business Administration facility located at 4000 Cooper Street in Jackson, MI. The drawings detail the installation requirements for security cameras, access control systems, and related communications infrastructure for Blocks 4 and 5 of Building 17. The project scope includes installation of surveillance cameras, door access controls, monitoring stations, and associated cabling and connectivity requirements.
The detailed technical drawings include communication symbol legends, equipment schedules, cable schedules, installation details for cameras and access control devices, raceway specifications, and floor plans showing camera and equipment placement. The drawings were prepared by Commtech Design of Rockford, MI under file number 472/18441.JNS. The plans show specific requirements for camera mounting, cabling pathways, hardware connectivity, and monitoring station configurations across multiple areas of the facility including interior spaces and exterior locations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATE OF MICHIGAN
SOUTHERN REGION TRANSPORTATION MOVE TO 5 BLOCK
VIDEO SECURITY AND ACCESS CONTROL
JACKSON BUSINESS ADMINISTRATION
4000 COOPER STREET
JACKSON, MI 49201
INDEX NUMBER:
FILE NUMBER: 472/18441.JNS
SECURITY DESIGN
COMMTECH DESIGN
6581 BELDING RD. NE, SUITE 101
ROCKFORD, MI 49341
(616) 863-8132
SECURITY DRAWING INDEX
JACKSON BUSINESS ADMINISTRATION
BLOCK 4 BLOCK 5
BUILDING 17
N
N
TITLE
C o m m t e c h
D e s i g n
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
B
E L D
I N
G
R
D
N
E
S
U I T
E
R O
C K
F O
R D
M
I C
H I G
A N
W W
W C
O M
M T
E C
H D
E S
I G
N C
O M
AutoCAD SHX Text TC101 SECURITY LEGENDS AND DETAILS SECURITY LEGENDS AND DETAILS TC102 DATA CABLING CONNECTIVITY DATA CABLING CONNECTIVITY TC103 VIDEO SECURITY DETAILS AND ONE-LINE DIAGRAM VIDEO SECURITY DETAILS AND ONE-LINE DIAGRAM TC901 BLDG. 17, BLOCK 5 AND BLOCK 4 FIRST FLOOR-AREAS A&B BLDG. 17, BLOCK 5 AND BLOCK 4 FIRST FLOOR-AREAS A&B TC902 BLOCK 4 FIRST FLOOR AND SITE PLAN-AREAS C&DBLOCK 4 FIRST FLOOR AND SITE PLAN-AREAS C&D
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
472/18411.JNS
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 1065_54
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
JACKSON, MICHIGAN
AutoCAD SHX Text
BID SET 1/18/2019
AutoCAD SHX Text MICHIGAN STATE PRISON - JACKSON BUSINESS ADMINISTRATION SOUTHERN REGION TRANSPORTATION MOVE TO 5 BLOCK VIDEO SECURITY AND ACCESS CONTROL
ABBREVIATIONS
ABBREV. DESCRIPTION ABBREV. DESCRIPTION
COMMUNICATION CABLE SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
COMMUNICATION EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
COMMUNICATION SYMBOL LEGEND
SYMBOL DESCRIPTION
SECURITY EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
NETWORK EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
CAMERA EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
TC101
TYPICAL FACEPLATE LABELING
TC101
TYPICAL CABLE LABELING
AT FACEPLATE & PATCH PANEL
TC101
CAMERA OR WIRELESS PANEL LABELING
TC101
TYPICAL SURFACE RACEWAY
INSTALLED BY COMM CONTRACTOR
TC101
CONNECTIVITY CODE
TC101
CONNECTIVITY CODE
TC101
CONNECTIVITY CODE
TC101
BASEMENT COMM ROOM
RACK LAYOUTS
TC101
CONNECTIVITY CODE
ACCESS CONTROL EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
TC101
CONNECTIVITY CODE
TC101
DATA CABLE DETAILS AND
CONNECTIVITY CODES
C o m m t e s i g n
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
B
E L D
I N
G
R
D
N
E
S
U I T
E
R O
C K
F O
R D
M
I C
H I G
W W
W C
O M
M T
E C
H D
E S
I G
N C
O M
AutoCAD SHX Text 54" A.F.F.
AutoCAD SHX Text 54" A.F.F.
AutoCAD SHX Text 2G
AutoCAD SHX Text
TWO-GANG BOX - PROVIDED BY EC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
AC
AutoCAD SHX Text ABOVE COUNTER - INSTALL BACKBOX SAME HEIGHT AS OTHER ELECTRICAL OUTLETS ABOVE THE COUNTER.
AutoCAD SHX Text
PBO
AutoCAD SHX Text
PROVIDED BY OTHERS
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
PATCH CORD ORGANIZER - 1 UNIT HIGH
AutoCAD SHX Text
AFG
AutoCAD SHX Text
ABOVE FINISHED GROUND
AutoCAD SHX Text
PCO-2
AutoCAD SHX Text
PATCH CORD ORGANIZER - 2 UNITS HIGH
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AMERICAN WIRE GAUGE
AutoCAD SHX Text
PER
AutoCAD SHX Text
PROTECTED ENTRANCE TERMINAL
AutoCAD SHX Text
C-EMT
AutoCAD SHX Text
EMT TYPE CONDUIT
AutoCAD SHX Text
QTY
AutoCAD SHX Text
QUANITY
AutoCAD SHX Text
EC
AutoCAD SHX Text
ELECTRICAL CONTRACTOR
AutoCAD SHX Text
PLENUM RATED, GREEN, CAT-6 CABLE FOR ETHERNET CONNECTIVITY.
AutoCAD SHX Text
GENERAL CABLE
AutoCAD SHX Text 7131806
AutoCAD SHX Text
CAT-6 RATED PATCH CORD. FIELD VERIFY LENGTH.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text HC6GNxx
AutoCAD SHX Text 24 PORT PATCH PANEL "UNLOADED"- PANEL SHALL BE EQUIP WITH MODULAR JACKS FOR TERMINATION OF ALL CABLES. EQUIP WITH REAR ORGANIZER
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
UDX24E/ HXJ6GN/ECMBR3
AutoCAD SHX Text
PATCH CORD ORGANIZER (PCO-1), SINGLE RACK UNIT WITH HINGED COVER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HC119ME3N/HC219C
AutoCAD SHX Text
RACK SHELF
AutoCAD SHX Text
ORTRONICS
AutoCAD SHX Text
OR-604045401
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text EQUIPMENT SCHEDULE IDENTIFIER, REFER TO APPROPRIATE SCHEDULE FOR EQUIPMENT AND REQUIREMENTS.
AutoCAD SHX Text
CABLING SCHEDULE IDENTIFIER, REFER TO CABLING SCHEDULE FOR CABLING REQUIREMENTS.
AutoCAD SHX Text NEW SECURITY CAMERA LOCATION, TO BE INSTALLED - LINES IDENTIFY PROPOSED VIEW, CONFIRM WITH OWNER BEFORE INSTALLATION.
AutoCAD SHX Text
CAMERA IDENTIFIER - CCC = SITE CODE - YY = BUILDING NUMBER/XX = CAMERA NUMBER
AutoCAD SHX Text NEW PERIMETER NETWORK CABINET WITH FIBER CONNECTIVITY. CABINET PROVIDES LOCAL CONNECTIONS TO CAMERAS AND LIGHTING FOR CONTROL. REFER TO DETAILS FOR CABINET EQUIPMENT BUILD OUTS.
AutoCAD SHX Text COMMUNICATIONS WORK AREA OUTLET LOCATION - X = REFER TO CONNECTIVITY CODES FOR REQUIRED BUILD-OUT.
AutoCAD SHX Text COMMUNICATION WORK AREA OUTLET IN SURFACE MOUNTED RACEWAY - PROVIDE IDENTIFIED CONNECTIVITY CODE AND RACEWAY AT THIS LOCATION
AutoCAD SHX Text MONITOR AND MOUNT LOCATION - REFER TO DETAILS FOR MOUNTING AND CABLING REQUIRMENTS.
AutoCAD SHX Text PERSONAL COMPUTER WORK STATION - REFER TO DETAILS FOR REQUIRED EQUIPMENT AND CABLING.
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
CCC-YYXX
AutoCAD SHX Text C
AutoCAD SHX Text
CAB-XXX
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
LCD.XX"
AutoCAD SHX Text
PC
AutoCAD SHX Text VIDEO SECURITY NVR AND RECORDING SOFTWARE. PROVIDE AND INSTALL A SERVER OR SERVERS WITH THE PROCESSING AND STORAGE TO MEET THE OWNERS NEED AS DETAILED ON THE DRAWINGS AND SPECS.
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text SECURITY MONITORING PC. FOUR (4) HDMI OUTPUTS. EQUIP WITH SOFTWARE THAT ALLOWS NETWORK CONNECTION TO THE NVR AND HAS ANY AND ALL SOFTWARE REQUIRED. TO CONFIGURE, REVIEW AND COPY/WRITE VIDEO TO A DVD WRITER. PC SHALL HAVE GRAPHICS CARD TO SUPPORT FOUR (4) HDMI CONNECTIONS.
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text 27" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS. PROVIDE A TABLE TOP MOUNT AND ALL CABLING REQUIRED.
AutoCAD SHX Text
NEC
AutoCAD SHX Text
EA273WMI-BK
AutoCAD SHX Text
SC
AutoCAD SHX Text
SB
AutoCAD SHX Text
SA
AutoCAD SHX Text ETHERNET SWITCH WITH PoE FOR ALL PORTS. 24 PORT WITH SFP MODULES AS REQUIRED FOR COMPLETE CONNECTIVITY.
AutoCAD SHX Text
CISCO
AutoCAD SHX Text C9300-48P-E
AutoCAD SHX Text 1500VA UPS. INSTALL, CONNECT TO EMERGENCY POWER. FLOOR MOUNT. SHALL RUN EQUIPMENT FOR 10 MINUTES.
AutoCAD SHX Text
LIEBERT
AutoCAD SHX Text
GXT41500RT120
AutoCAD SHX Text
NA
AutoCAD SHX Text
NB
AutoCAD SHX Text EXTERIOR, FIXED, WALL/POLE-MOUNTED CAMERA. 3072 x 1728 MINIMUM EFFECTIVE PIXELS. INCLUDE ALL MOUNTING ACCESSORIES.
AutoCAD SHX Text
BOSCH
AutoCAD SHX Text
CAM: NDE-5503-A WALL: NDA-U-WMT
AutoCAD SHX Text
INDOOR, HIGH RESOLUTION 360° CAMERA. 12.4 MEGAPIXEL.
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
CAM: WV-SFV481
AutoCAD SHX Text
INDOOR, 360° CAMERA. 5 MEGAPIXEL.
AutoCAD SHX Text
BOSCH
AutoCAD SHX Text
CAM: NUC-52051-F0E
AutoCAD SHX Text INDOOR, FIXED, DOME CAMERA. 1952 X 1092 MINIMUM EFFECTIVE PIXELS. INCLUDE ALL MOUNTING ACCESSORIES.
AutoCAD SHX Text
BOSCH
AutoCAD SHX Text
CAM: NDE-4502-A
AutoCAD SHX Text
CD
AutoCAD SHX Text
CC
AutoCAD SHX Text
CB
AutoCAD SHX Text
CA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text A-Y
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
A-Y-CC
AutoCAD SHX Text
DATA
AutoCAD SHX Text
A-Y-CC
AutoCAD SHX Text
CC
AutoCAD SHX Text
CC
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text A-Y
AutoCAD SHX Text
CC
AutoCAD SHX Text
CC
AutoCAD SHX Text
%%USURFACE MOUNT OUTLET
AutoCAD SHX Text
%%UPHONE PLATE
AutoCAD SHX Text
%%USTANDARD PLATE
AutoCAD SHX Text NOTES: 1. INSTALL A PAPER LABEL BEHIND THE INSTALL A PAPER LABEL BEHIND THE PLASTIC WINDOW IN STANDARD PLATES THAT ARE EQUIPPED WITH THE WINDOWS. 2. PROVIDE ADHESIVE LABELS ON WALL PROVIDE ADHESIVE LABELS ON WALL PHONE PLATES & SURFACE MOUNT OUTLETS & PLATES WITHOUT LABELING WINDOWS.
AutoCAD SHX Text DATA CABLE LABEL: A = COMMUNICATIONS ROOM, A, B, ETC. Y = PATCH PANEL IN THAT RACK OR CABINET 1-X CC = PORT ON THAT PANEL FROM 01-24
AutoCAD SHX Text
ADHESIVE LABEL
AutoCAD SHX Text
PAPER BEHIND WINDOW
AutoCAD SHX Text
A-Y-CC
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text 33-3204-02
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text 33-3204-02
AutoCAD SHX Text
A-Y-CC
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
BACK OF PATCH PANEL IN COMM ROOM
AutoCAD SHX Text
BACK OF FACEPLATE
AutoCAD SHX Text NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. 2. WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE SELF-LAMINATING.
AutoCAD SHX Text CABLE LABEL: A = COMMUNICATIONS ROOM NUMBER. A, B OR C ETC. Y = PATCH PANEL IN THAT COMMUNICATIONS ROOM CC = PORT NUMBER ON PATCH PANEL 0-24. DDD = CAMERA OR WAP NUMBER
AutoCAD SHX Text NOTES: 1. INSTALL A LABEL TO EACH PATCH INSTALL A LABEL TO EACH PATCH PANEL DETAILING THE COMM ROOM NUMBER AND PATCH PANEL NUMBER. EACH PANEL IS PRE-NUMBERED 01-24 ON EACH PANEL. 2. ALL LABELS ADDED TO THE PANEL ALL LABELS ADDED TO THE PANEL SHALL BE LASER PRINTED AND CUT TO FIT. ALL NUMBERS SHALL EXACTLY ALIGN WITH THE LOCATION ON THE PATCH PANEL. 3. IF THE PANEL IS NOT PRE-LABELED IF THE PANEL IS NOT PRE-LABELED 01-24 THEN THE CONTRACTOR SHALL INSTALL A LABEL FOR EACH PORT. 4. THE CABLES SHALL BE TERMINATED ON THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL IN NUMERICAL ORDER. NO EXCEPTIONS. 5. ADD LABELS FOR CAMERA NUMBERS OR ADD LABELS FOR CAMERA NUMBERS OR WAP NUMBERS DEPENDING UPON PATCH PANEL. SEE RACK LAYOUTS TO DETERMINE IF CAMERA AND WAP CABLES WILL BE ON SEPARATE OR SHARED PATCHPANELS
AutoCAD SHX Text DATA CABLE LABELING A-Y-CC A = COMMUNICATIONS ROOM NUMBER. A, B OR C ETC. Y = PATCH PANEL IN THAT COMMUNICATIONS ROOM CC = PORT NUMBER ON PATCH PANEL 1-24. DDD = CAMERA NUMBER. MEET WITH OWNER AND SECURITY CONTRACTOR TO OBTAIN THIS NUMBER WAP = WAP NUMBER. MEET WITH OWNER TO OBTAIN THIS NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AY
AutoCAD SHX Text
AY
AutoCAD SHX Text
LABEL PATCH PANELS CONSECUTIVELY IN THE COMM ROOM, 1-99
AutoCAD SHX Text
COMM ROOM DESIGNATOR. A OR IDF1 ETC. SEE FLOORPLANS
AutoCAD SHX Text
ADHESIVE LABEL (TYPICAL)
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text
DDD
AutoCAD SHX Text ADHESIVE LABEL (TYPICAL). COORDINATE WITH OWNER AND OTHER CONTRACTORS TO OBTAIN DEVICE NUMBERS. ADD THESE TO THE PANEL
AutoCAD SHX Text
FACEPLATE
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text
SURFACE BACKBOX
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # SINGLE-GANG BACKBOX -NO KNOCKOUTS. 1" EMT CONDUIT. USE COMPRESSION COUPLERS USE TWO-HOLE CONDUIT STRAPS WITH SECURITY SCREWS
AutoCAD SHX Text INDICATES THAT THE CABLES AT THIS LOCATION SHALL BE INSTALLED THROUGH NEW SURFACE RACEWAY & BACKBOX
AutoCAD SHX Text
18" A.F.F. OR AS NOTED ON FLOOR PLANS
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 FACEPLATE HUBBELL IMF1OW FACEPLATE HUBBELL IMF1OW HUBBELL IMF1OW IMF1OW 2 CAT-6 CABLES GENERAL 7131800 CAT-6 CABLES GENERAL 7131800 GENERAL 7131800 7131800 2 CAT-6 JACK HUBBELL HXJ6OW CAT-6 JACK HUBBELL HXJ6OW HUBBELL HXJ6OW HXJ6OW 1 TWO-HOLE KEYSTONE HUBBELL IM2K1OW TWO-HOLE KEYSTONE HUBBELL IM2K1OW HUBBELL IM2K1OW IM2K1OW 2 1 UNIT BLANK HUBBELL IMB1OW1 UNIT BLANK HUBBELL IMB1OWHUBBELL IMB1OWIMB1OW
AutoCAD SHX Text
1" CONDUIT WITH A TWO-GANG BACKBOX & A SINGLE-GANG MUDRING BY E.C.
AutoCAD SHX Text
COMMUNICATION CABLES
AutoCAD SHX Text
WALL
AutoCAD SHX Text
FACEPLATE
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
DATA
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 FACEPLATE HUBBELL IMF1OW FACEPLATE HUBBELL IMF1OW HUBBELL IMF1OW IMF1OW 3 CAT-6 CABLES GENERAL 7131800 CAT-6 CABLES GENERAL 7131800 GENERAL 7131800 7131800 3 CAT-6 JACK HUBBELL HXJ6OW CAT-6 JACK HUBBELL HXJ6OW HUBBELL HXJ6OW HXJ6OW 1 TWO-HOLE KEYSTONE HUBBELL IM2K1OW TWO-HOLE KEYSTONE HUBBELL IM2K1OW HUBBELL IM2K1OW IM2K1OW 1 ONE-HOLE KEYSTONE HUBBELL IM1K1OW ONE-HOLE KEYSTONE HUBBELL IM1K1OW HUBBELL IM1K1OW IM1K1OW 1 1 UNIT BLANK HUBBELL IMB1OW1 UNIT BLANK HUBBELL IMB1OWHUBBELL IMB1OWIMB1OW
AutoCAD SHX Text
1" CONDUIT WITH A TWO-GANG BACKBOX & A SINGLE-GANG MUDRING BY E.C.
AutoCAD SHX Text
COMMUNICATION CABLES
AutoCAD SHX Text
WALL
AutoCAD SHX Text
FACEPLATE
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 FACEPLATE HUBBELL IMF1OW FACEPLATE HUBBELL IMF1OW HUBBELL IMF1OW IMF1OW 4 CAT-6 CABLES GENERAL 7131800 CAT-6 CABLES GENERAL 7131800 GENERAL 7131800 7131800 4 CAT-6 JACK HUBBELL HXJ6OW CAT-6 JACK HUBBELL HXJ6OW HUBBELL HXJ6OW HXJ6OW 2 TWO-HOLE KEYSTONE HUBBELL IM2K1OW TWO-HOLE KEYSTONE HUBBELL IM2K1OW HUBBELL IM2K1OW IM2K1OW 1 1 UNIT BLANK HUBBELL IMB1OW1 UNIT BLANK HUBBELL IMB1OWHUBBELL IMB1OWIMB1OW
AutoCAD SHX Text
1" CONDUIT WITH A TWO-GANG BACKBOX & A SINGLE-GANG MUDRING BY E.C.
AutoCAD SHX Text
COMMUNICATION CABLES
AutoCAD SHX Text
WALL
AutoCAD SHX Text
FACEPLATE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING RACK
AutoCAD SHX Text
BASEMENT COMM ROOM
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text GENERAL NOTES: 1. ALL USER DATA CABLES SHALL ROUTE IN THE CEILING & ALL USER DATA CABLES SHALL ROUTE IN THE CEILING & THEN ROUTE D0WN VERTICAL CABLE LADDER TO THE RACK. AT THE RACK/CABINET, PROVIDE A "DRIP LOOP" FOR ALL THE CABLES DRIP LOOP SHALL BE A MINIMUM OF ONE FOOT. 2. CONNECT ALL RACKS, CABINETS AND CABLE LADDER TO THE CONNECT ALL RACKS, CABINETS AND CABLE LADDER TO THE GROUND BAR AS DESCRIBED IN THE GROUNDING DETAIL DETAIL & THE GROUNDING SPECIFICATIONS. 3. FIELD VERIFY EXISTING RACK LAYOUT AND ACCOMMODATE FIELD VERIFY EXISTING RACK LAYOUT AND ACCOMMODATE NEW EQUIPMENT AS NEEDED.
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
PATCH PANEL 1-24
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
PATCH PANEL 1-24
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text %%uCONNECTIVITY CODE
AutoCAD SHX Text
AutoCAD SHX Text
%%UPARTS
AutoCAD SHX Text
COMMUNICATION CABLE
AutoCAD SHX Text QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL ISM1OW SURFACE BOX HUBBELL ISM1OW HUBBELL ISM1OW ISM1OW 1 CAT-6 CABLE GENERAL 7131800 CAT-6 CABLE GENERAL 7131800 GENERAL 7131800 7131800 1 CAT-6 JACK HUBBELL HXJ6OWCAT-6 JACK HUBBELL HXJ6OWHUBBELL HXJ6OWHXJ6OW
AutoCAD SHX Text
WALL
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
INTERCOM
AutoCAD SHX Text
INTERCOM
AutoCAD SHX Text
INTERCOM BY SECURITY CONTRACTOR
AutoCAD SHX Text 54" A.F.F.
AutoCAD SHX Text 54" A.F.F.
AutoCAD SHX Text
SURFACE BOX
AutoCAD SHX Text
1" CONDUIT WITH A TWO-GANG BACKBOX AND A SINGLE-GANG MUDRING
AutoCAD SHX Text
1" CONDUIT WITH A TWO-GANG BACKBOX AND A SINGLE-GANG MUDRING
AutoCAD SHX Text
ACCESS CONTROL SYSTEM, SOFTWARE AND ASSOCIATED/REQUIRED SERVERS
AutoCAD SHX Text
GENETEC
AutoCAD SHX Text
GENETEC
AutoCAD SHX Text
INTERCOM BASE STATION
AutoCAD SHX Text
AIPHONE
AutoCAD SHX Text
IX-MV7-HW
AutoCAD SHX Text
IP PROGRAMMABLE RELAY
AutoCAD SHX Text
AIPHONE
AutoCAD SHX Text
RY-IP44
AutoCAD SHX Text INTERCOM -SURFACE MOUNT. EQUIP WITH CUSTOM BACKBOX AND PUSHBUTTON BELOW. CUSTOM WIRE TO SUPPORT ADA APPROVED CALL BUTTON HEIGHT
AutoCAD SHX Text
AIPHONE /ALARM CONTROLS
AutoCAD SHX Text
IX-DV
AutoCAD SHX Text
TD
AutoCAD SHX Text
TC
AutoCAD SHX Text
TB
AutoCAD SHX Text
TA
AutoCAD SHX Text
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
%%UABOVE DROP CEILING INSTALLATION
AutoCAD SHX Text
%%UOPEN CEILING INSTALLATION
AutoCAD SHX Text
SECURITY CAMERA
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL ISM1OW SURFACE BOX HUBBELL ISM1OW HUBBELL ISM1OW ISM1OW 1 CAT-6 CABLE-GREEN GENERAL 7131806 CAT-6 CABLE-GREEN GENERAL 7131806 GENERAL 7131806 7131806 1 CAT-6 JACK HUBBELL HXJ6GNCAT-6 JACK HUBBELL HXJ6GNHUBBELL HXJ6GNHXJ6GN
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE NEAR THE SECURITY CAMERA LOCATION. 2. SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT FOR SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT FOR LOCATIONS WHERE THE CAMERA IS IN AN OPEN CEILING
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
CAT-6 PATCH
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text
CAT-6 CABLE TO COMM ROOM
AutoCAD SHX Text
ATTACH TO BLDG STRUCTURE
AutoCAD SHX Text
CAT-6 CABLE TO COMM ROOM
AutoCAD SHX Text
15' COIL OF CABLE
AutoCAD SHX Text
CAT-6 PATCH
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
472/18411.JNS
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 1065_54
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
JACKSON, MICHIGAN
AutoCAD SHX Text
BID SET 1/18/2019
MICHIGAN STATE PRISON - JACKSON BUSINESS ADMINISTRATION SOUTHERN REGION TRANSPORTATION MOVE TO 5 BLOCK VIDEO SECURITY AND ACCESS CONTROL
TC102
ACCESS CONTROL
RACEWAY DETAIL
TC102
DOOR HARDWARE & SECURITY
EQUIPMENT CONNECTIVITY REQUIREMENTS
ACCESS CONTROL SYSTEM DETAILS
ACCESS CONTROL SYSTEM DETAILS
TC102
ENTRY DOOR
INTERCOM CONNECTIVITY DIAGRAM
C o m m t e s i g n
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
B
E L D
I N
G
R
D
N
E
S
U I T
E
R O
C K
F O
R D
M
I C
H I G
W W
W C
O M
M T
E C
H D
E S
I G
N C
O M
TC102
ACCESS CONTROL RACEWAY
DETAILS AND CONNECTIVITY
REQUIREMENTS
AutoCAD SHX Text
INTERCONNECTION FOR POWERING ALL FIELD DEVICES
AutoCAD SHX Text
NEW GENETEC SECURITY PANEL IN BASEMENT
AutoCAD SHX Text POWER SUPPLY FOR POWERING FIELD DEVICES SUCH AS ELECTRIC STRIKES, MOTION REQUEST TO EXIT. 24 VOLT OR 12 VOLT BASED ON DOOR & FIELD EQUIP.
AutoCAD SHX Text
AutoCAD SHX Text
DC
AutoCAD SHX Text
ES
AutoCAD SHX Text
EL
AutoCAD SHX Text
MX
AutoCAD SHX Text
CR
AutoCAD SHX Text
BR
AutoCAD SHX Text
IC
AutoCAD SHX Text
BS
AutoCAD SHX Text
"CR" CABLE
AutoCAD SHX Text
"BR" CABLE
AutoCAD SHX Text
"BS" CAT-6 DATA CABLE TO NETWORK
AutoCAD SHX Text
"IC" CAT-6 DATA CABLE TO COMM ROOM
AutoCAD SHX Text
CAT-6 DATA CABLE TO RACK
AutoCAD SHX Text
INTERCOM DEVICE
AutoCAD SHX Text
CABLE AS REQUIRED
AutoCAD SHX Text
"ES" CABLE
AutoCAD SHX Text
"DC" CABLE
AutoCAD SHX Text
"EL" CABLE
AutoCAD SHX Text
"RX" CABLE
AutoCAD SHX Text
PROXIMITY CARD READER
AutoCAD SHX Text
BIOMETRIC & CARD READER
AutoCAD SHX Text
INTERCOM BASE STATION
AutoCAD SHX Text
INTERCOM
AutoCAD SHX Text
SINGLE-GANG BACKBOX
AutoCAD SHX Text
DOOR FRAME
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
LATCH SIDE OF DOOR
AutoCAD SHX Text
HINGE SIDE OF DOOR
AutoCAD SHX Text
WIRING HARNESS BY DOOR HARDWARE
AutoCAD SHX Text
RACEWAY, SEE OTHER DETAILS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
AutoCAD SHX Text
ML
AutoCAD SHX Text
MAGNETIC LOCK POWER
AutoCAD SHX Text
TERMINATE CONDUIT AT DOOR FRAME
AutoCAD SHX Text
"ML" CABLE
AutoCAD SHX Text
MX
AutoCAD SHX Text
AutoCAD SHX Text GENERAL NOTES: 1. SEE DETAIL TC102/1 FOR RACEWAY NOTES. SEE DETAIL TC102/1 FOR RACEWAY NOTES. 2. REFER TO THE PLAN DRAWINGS FOR THE SPECIFIC FIELD DEVICE AND REFER TO THE PLAN DRAWINGS FOR THE SPECIFIC FIELD DEVICE AND WHERE IT IS TO BE INSTALLED. 3. AT SOME LOCATIONS THE CARD READER WILL HAVE TO BE INSTALLED AT SOME LOCATIONS THE CARD READER WILL HAVE TO BE INSTALLED INTO THE DOOR FRAME. PROVIDE A FRAME TYPE READER AT THESE LOCATIONS. 4. ALL SECURITY DEVICES SHALL BE WIRED DIRECTLY BACK TO THE ALL SECURITY DEVICES SHALL BE WIRED DIRECTLY BACK TO THE SECURITY SYSTEM PANELS. LOCATE PANELS ON THE WALLS OF COMMUNICATIONS ROOMS OR AS SHOWN ON THE FLOOR PLANS. 5. PROVIDE ALL SECURITY CABLES AND ALL SECURITY PANELS REQUIRED PROVIDE ALL SECURITY CABLES AND ALL SECURITY PANELS REQUIRED FOR CONNECTIVITY OF THE SYSTEM. 6. LABEL THE OUTSIDE OF THE PANEL FOR THE DOORS AND DEVICES THAT LABEL THE OUTSIDE OF THE PANEL FOR THE DOORS AND DEVICES THAT ARE CONNECTED INSIDE THE PANEL. PROVIDE A PANEL DIAGRAM INSIDE THE PANEL THAT SHOWS THE CARDS AND WHAT IS CONNECTED TO EACH PORT ON THE CARDS.
AutoCAD SHX Text KEYED NOTES: MEET WITH THE OWNER TO DETERMINE WHAT THE TOGGLE SWITCH WILL CONTROL. SHALL HAVE SEPARATE CONTROLS FOR EACH POSITION. CONTRACTOR SHALL EXTEND POWER FROM EXISTING OUTLET TO THE POWER SUPPLIES ON THE WALL. PROVIDE ALL RACEWAY AND WIRING FOR EXTENSION OF POWER. FOR AN EL OR LR DEVICE THE DOOR HARDWARE SUPPLIER WILL PROVIDE A WIRING HARNESS FROM THE LOCK THROUGH THE HINGE AND INTO THE DOOR FRAME. SECURITY CONTRACTOR TO WIRE FROM PANEL OR POWER SUPPLY TO THE WIRING HARNESS. PROVIDE A POWER SUPPLY TO SUPPORT THE ACCESS CONTROL PANEL AND FIELD DEVICES. WIRE TO THE PANEL AND 120 VOLT POWER. WIRE MAGNETIC LOCK TO CONTROL THE LOCK ON OR OFF FROM THE ACCESS CONTROL SYSTEM CONNECT THE FIRE ALARM SYSTEM TO THE ACCESS CONTROL SYSTEM TO UNLOCK ONE OR MORE DOORS AND RELEASE ANY HOLD OPENS IN CASE OF A FIRE ALARM.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text CARD READER - INSTALL TO THE BACKBOX OR IN THE DOOR FRAME. COORDINATE IN FIELD PRIOR TO ORDERING. WIRE TO SECURITY SYSTEM
AutoCAD SHX Text BIOMETRIC READER - DEVICE TO USE A PERSONS BIOMETRICS TO ALLOW ENTRY. INSTALL TO THE BACKBOX WIRE TO SECURITY SYSTEM
AutoCAD SHX Text ELECTRIFIED LATCH - DEVICE IS IN THE DOOR, PROVIDED BY DOOR CONTRACTOR. WIRE THROUGH THE DOOR, THROUGH THE HINGE AND TO THE SECURITY PANEL
AutoCAD SHX Text ELECTRIC STRIKE - STRIKE IS PROVIDED AND INSTALLED BY DOOR CONTRACTOR. WIRE FROM THIS DEVICE TO SECURITY PANEL. PROVIDE POWER SUPPLY IN COMM ROOM.
AutoCAD SHX Text MAGNETIC LOCK: THE LOCK SHALL BE PROVIDED BY THE DOOR HARDWARE SUPPLIER. WIRE FROM THIS DEVICE TO THE ACCESS CONTROL PANEL FOR CONTROL OF LOCKING AND UNLOCKING
AutoCAD SHX Text INTERCOM - INSTALL TO THE BOX OR SURFACE MOUNT TO THE WALL. WIRE TO THE COMM ROOM VIA CAT-6 CABLE.
AutoCAD SHX Text INTERCOM BASE SYSTEM - THIS DEVICE SHALL BE INSTALLED AT THE RECEPTION DESK. WIRE TO COMM ROOM VIA CAT-6 CABLE.
AutoCAD SHX Text PUSH BUTTON - THIS SHALL TRIGGER A SINGLE EVENT OR SERIES OF EVENTS IN THE SECURITY SYSTEM WHEN DEPRESSED. BELOW DESK, WIRE TO SECURITY PANEL.
AutoCAD SHX Text REQUEST TO EXIT IN LOCK - THIS IS A SWITCH THAT IS PROVIDED WITH THE DOOR LOCKING DEVICE. WIRE TO SECURITY PANEL TO SHUNT DOOR CONTACT WHEN EXITING BLDG.
AutoCAD SHX Text DOOR CONTACT - MOUNT ABOVE THE DOOR. WIRE TO SECURITY SYSTEM/INTRUSION DETECTION SYSTEM TO TRIGGER AN ALARM
AutoCAD SHX Text TOGGLE SWITCH - INSTALL THE TOGGLE SWITCH TO A DESK, UNDERSIDE. WIRE TO THE ACCESS CONTROL SYSTEM. SWITCH SHALL START ONE SEQUENCE WHEN SWITCHED EITHER WAY. IN EXAMPLE. ENGAGE AND DISENGAGE A MAGNETIC LOCK.
AutoCAD SHX Text MOTION SENSOR REQUEST TO EXIT - MOUNT ABOVE THE DOOR. WIRE TO SECURITY SYSTEM/ACCESS CONTROL SYSTEM TO SHUNT DOOR CONTACT WHEN EXITING BLDG.
AutoCAD SHX Text LATCH RETRACTION DEVICE - THIS DEVICE IS AN ELECTRONIC PUSHBAR ON THE SECURE SIDE OF THE DOOR. WIRE FROM THIS DEVICE, THROUGH THE DOOR HINGETO THE POWER SUPPLY IN THE CEILING. POWER SUPPLY IS BY DOOR CONTRACTOR.
AutoCAD SHX Text
CR
AutoCAD SHX Text
BR
AutoCAD SHX Text
EL
AutoCAD SHX Text
ES
AutoCAD SHX Text
IC
AutoCAD SHX Text
BS
AutoCAD SHX Text
PB
AutoCAD SHX Text
RX
AutoCAD SHX Text
DC
AutoCAD SHX Text
TS
AutoCAD SHX Text
ML
AutoCAD SHX Text
SECURITY PANEL XX
AutoCAD SHX Text
DOOR XX DOOR XX LOCKDOWN BUTTON ETC.
AutoCAD SHX Text
ADHESIVE LABELS
AutoCAD SHX Text
CARDS IN PANEL
AutoCAD SHX Text
CARD 1 A121-DC A121-CR A121-RX
AutoCAD SHX Text
TYPICAL ACCESS CONTROL PANEL LABELING
AutoCAD SHX Text
NEATLY INSTALL CABLES
AutoCAD SHX Text
PANEL DIAGRAM
AutoCAD SHX Text
PB
AutoCAD SHX Text
TS
AutoCAD SHX Text
"PB" CABLE
AutoCAD SHX Text
AutoCAD SHX Text
"TS" CABLE
AutoCAD SHX Text
120 VAC BY E.C.
AutoCAD SHX Text
DESK TOP
AutoCAD SHX Text
EXISTING FIRE ALARM SYSTEM
AutoCAD SHX Text
"FA" CABLE
AutoCAD SHX Text
AutoCAD SHX Text
DC
AutoCAD SHX Text
ES
AutoCAD SHX Text
MX
AutoCAD SHX Text
INTERCOM
AutoCAD SHX Text
INSTALL NEW SECURITY PANEL, LOCATED IN BASEMENT. PROVIDE 120 VOLT POWER.
AutoCAD SHX Text
SINGLE-GANG BACKBOX
AutoCAD SHX Text
DOOR FRAME
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
LATCH SIDE OF DOOR
AutoCAD SHX Text
HINGE SIDE OF DOOR
AutoCAD SHX Text
WIRING HARNESS BY DOOR HARDWARE
AutoCAD SHX Text
ML
AutoCAD SHX Text
TERMINATE CONDUIT AT DOOR FRAME
AutoCAD SHX Text
MAGNETIC LOCK POWER SUPPLY
AutoCAD SHX Text 3/4" C
AutoCAD SHX Text 1" C
AutoCAD SHX Text
IC
AutoCAD SHX Text
2-GANG BACKBOX AT 46" AFF ON CENTER
AutoCAD SHX Text
2-GANG BACKBOX WITH SINGLE-GANG MUDRING AT 46" AFF ON CENTER
AutoCAD SHX Text
CR
AutoCAD SHX Text
CARD READER
AutoCAD SHX Text
BR
AutoCAD SHX Text
BIOMETRIC CARD READER
AutoCAD SHX Text 3/4" C
AutoCAD SHX Text
2-GANG BACKBOX WITH SINGLE-GANG MUDRING AT 46" AFF ON CENTER
AutoCAD SHX Text
BOX AND CONDUIT TYPICAL FOR DEVICES LISTED
AutoCAD SHX Text 1" C
AutoCAD SHX Text
DESKTOP
AutoCAD SHX Text
PB
AutoCAD SHX Text
PUSH BUTTON
AutoCAD SHX Text
TS
AutoCAD SHX Text
TOGGLE SWITCH
AutoCAD SHX Text
CR
AutoCAD SHX Text
BS
AutoCAD SHX Text
BASE STATION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4" C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BOX AND CONDUIT TYPICAL FOR DEVICES LISTED
AutoCAD SHX Text 3/4" C
AutoCAD SHX Text
120 VAC BY E.C.
AutoCAD SHX Text
120 VAC BY E.C.
AutoCAD SHX Text CARD READER - PROXIMITY DEVICE BESIDE A DOOR. PROVIDE BACKBOX AND CONDUIT. WHERE NOTED TO BE INSTALLED ON DOOR FRAME INSTALL CONDUIT TO DOOR FRAME
AutoCAD SHX Text BIOMETRIC READER - PROXIMITY DEVICE FOR FINGERPRINT AUTHENTICATION. INSTALL CONDUIT AND BACKBOX
AutoCAD SHX Text ELECTRIFIED LATCH - LOCK MECHANISM AT DOOR HANDLE. INSTALL CONDUIT TO DOOR HINGE.
AutoCAD SHX Text ELECTRIC STRIKE - ELECTRONIC LOCKING DEVICE IN DOOR FRAME AT LATCH. INSTALL CONDUIT TO DOOR LATCH
AutoCAD SHX Text MAGNETIC LOCK: LOCK AT HEADER OF DOOR. INSTALL CONDUIT FROM LOCK TO CEILING FOR POWER TO LOCAL POWER SUPPLY
AutoCAD SHX Text INTERCOM - DEVICE FOR AUDIO AND VIDEO CONNECTION TO UNSECURE SIDE OF DOOR. INSTALL CONDUITS AND BACKBOX.
AutoCAD SHX Text INTERCOM BASE SYSTEM - DEVICE FOR AUDIO AND VIDEO CONNECTION AT DESK. INSTALL CONDUITS AND BACKBOX TO UNDERSIDE OF DESK
AutoCAD SHX Text
TOGGLE SWITCH - TOGGLE SWITCH AT DESK. INSTALL CONDUIT AND BACKBOX BELOW DESK
AutoCAD SHX Text PUSH BUTTON - BUTTON AT DESK TO TRIGGER AN EVENT INSTALL CONDUIT AN BACKBOX BELOW DESK
AutoCAD SHX Text REQUEST TO EXIT IN LOCK - SWITCH INSIDE PUSHBAR OR ELECTRIC LATCH. INSTALL CONDUIT TO HINGE SIDE OF DOOR
AutoCAD SHX Text DOOR CONTACT - INSTALLED AT TOP OF DOOR FRAME ABOVE DOOR. INSTALL BACKBOX AT DOOR FRAME AND CONDUIT TO CEILING.
AutoCAD SHX Text MOTION SENSOR REQUEST TO EXIT - INSTALLED AT TOP OF DOOR FRAME ABOVE DOOR. INSTALL BACKBOX AT DOOR FRAME AND CONDUIT TO CEILING.
AutoCAD SHX Text LATCH RETRACTION DEVICE - LOCK MECHANISM INSIDE PUSHBAR OF DOOR. INSTALL CONDUIT TO DOOR HINGE.
AutoCAD SHX Text
CR
AutoCAD SHX Text
BR
AutoCAD SHX Text
EL
AutoCAD SHX Text
ES
AutoCAD SHX Text
TS
AutoCAD SHX Text
IC
AutoCAD SHX Text
BS
AutoCAD SHX Text
PB
AutoCAD SHX Text
DC
AutoCAD SHX Text
ML
AutoCAD SHX Text GENERAL NOTES: 1. INSTALL RACEWAYS AND BACKBOXES AT DOORS AND DESKS FOR CONNECTION OF SECURITY INSTALL RACEWAYS AND BACKBOXES AT DOORS AND DESKS FOR CONNECTION OF SECURITY AND ALARM DEVICES. 2. CONDUIT INSTALLER SHALL WORK WITH DOOR INSTALLER, DOOR HARDWARE CONTRACTOR CONDUIT INSTALLER SHALL WORK WITH DOOR INSTALLER, DOOR HARDWARE CONTRACTOR AND SECURITY CONTRACTOR WHEN INSTALLING CONDUITS. KEYED NOTES: ONLY ONE CONDUIT AND BACKBOX IS REQUIRED WHERE THESE DEVICES ARE INSTALLED AT THE SAME DESK WHEN THE "CR" IS SHOWN AS BEING ON A DOOR FRAME, DO NOT INSTALL A BACKBOX. INSTALL CONDUIT INTO THE DOOR FRAME INSTALL BACKBOX FACING DOWN AT HEADER OF DOOR FOR DC AND RX. INSTALL CONDUIT TO CEILING AREA. INSTALL A CONDUIT TO AN ACCESSIBLE CEILING AREA. ACCESS CONTROL PANEL WILL BE INSTALLED IN THE COMM ROOM. PROVIDE POWER TO THE PANEL COORDINATE LENGTH AND TERMINATION POINT OF CONDUIT WITH THE DOOR HARDWARE AND DOOR INSTALLER.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RX
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4" C
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
CAT-6 MODULAR JACK
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
DOOR LOCK CABLE
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
RELAY CABLE FOR TRIGGERING UNLOCK OF DOORS
AutoCAD SHX Text NOTES: 1. PROVIDE MANUFACTURERS PROVIDE MANUFACTURERS RECOMMENDED CABLES TO CONNECT ALL INTERCOM COMPONENTS. CABLES SHALL BE PLENUM RATED. 2. INSTALL THE INTERCOMS AT THE INSTALL THE INTERCOMS AT THE DOORS SHOWN. PROVIDE THE SURFACE MOUNT BOX AT EACH ENTRY LOCATION. 3. CONNECT THE PROGRAMMABLE TO CONNECT THE PROGRAMMABLE TO THE ACCESS CONTROL SYSTEM TO RELEASE THE LOCK ON THE DOOR NEAREST EACH ENTRY. 4. FULLY CONFIGURE THE SYSTEM TO FULLY CONFIGURE THE SYSTEM TO RELEASE THE LOCK AT THE DOOR WHERE THE EXTERIOR INTERCOM IS LOCATED.
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
TD
AutoCAD SHX Text
IC
AutoCAD SHX Text
TC
AutoCAD SHX Text
IP PROGRAMMABLE RELAY AIPHONE #RY-IP44
AutoCAD SHX Text
SEE FLOOR PLANS FOR LOCATIONS & QUANTITY
AutoCAD SHX Text
SEE FLOOR PLANS FOR LOCATIONS & QUANTITY
AutoCAD SHX Text
INTERCOM BASE STATION
AutoCAD SHX Text
BS
AutoCAD SHX Text
TB
AutoCAD SHX Text
INTERCOM BASE STATION
AutoCAD SHX Text
ACCESS CONTROL PANEL IN COMM ROOM
AutoCAD SHX Text
ELECTRIC STRIKE CONNECTION
AutoCAD SHX Text
FACEPLATE AT DESK
AutoCAD SHX Text
ETHERNET SWITCH POE
AutoCAD SHX Text
CAT-6 PATCH CABLES
AutoCAD SHX Text
CAT-6 PATCH PANEL
AutoCAD SHX Text
INTERCOM EXTERIOR
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
ES
AutoCAD SHX Text
TA
AutoCAD SHX Text
AutoCAD SHX Text
LR
AutoCAD SHX Text
LR
AutoCAD SHX Text
MX
AutoCAD SHX Text
AutoCAD SHX Text
MX
AutoCAD SHX Text
LR
AutoCAD SHX Text
LR
AutoCAD SHX Text
MX
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
472/18411.JNS
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 1065_54
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
JACKSON, MICHIGAN
AutoCAD SHX Text
BID SET 1/18/2019
MICHIGAN STATE PRISON - JACKSON BUSINESS ADMINISTRATION SOUTHERN REGION TRANSPORTATION MOVE TO 5 BLOCK VIDEO SECURITY AND ACCESS CONTROL
TC103
CAMERA THROUGH WALL
RACEWAY & SEALANT DETAIL
TC103
VIDEO SECURITY DIAGRAM
BLOCK 5 - UPGRADED CONNECTIVITY
TC103
MONITORING STATION LCD DISPLAY DETAIL
TC506
TYPICAL DROP-CEILING
CAMERA INSTALLATION
TC103
TYPICAL INTERIOR WALL/CEILING MOUNT
CAMERA INSTALLATION
TC103
EXTERIOR WALL MOUNT
CAMERA DETAILS
C o m m t e s i g n
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
B
E L D
I N
G
R
D
N
E
S
U I T
E
R O
C K
F O
R D
M
I C
H I G
W W
W C
O M
M T
E C
H D
E S
I G
N C
O M
TC103
VIDEO SECURITY DETAILS
AND ONE-LINE DIAGRAM
AutoCAD SHX Text
EXTERIOR WALL
AutoCAD SHX Text
SILICONE SEALANT
AutoCAD SHX Text
CAMERA BASE
AutoCAD SHX Text
RGS CONDUIT SIZE AS REQ'D
AutoCAD SHX Text
SILCONE SEALANT
AutoCAD SHX Text
CB
AutoCAD SHX Text
CD
AutoCAD SHX Text
CD
AutoCAD SHX Text
CB
AutoCAD SHX Text
CD
AutoCAD SHX Text
CC
AutoCAD SHX Text
CA
AutoCAD SHX Text
CA
AutoCAD SHX Text
KVM SWITCH
AutoCAD SHX Text
EXIST. DIRECTORY SERVER
AutoCAD SHX Text
EXIST. ARCHIVING SERVER #1
AutoCAD SHX Text
NEW ARCHIVING SERVER # "X"
AutoCAD SHX Text QTY OF SERVERS TBD BY CONTRACTOR DURING BIDDING. SEE SPECS FOR RECORDING REQUIREMENTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING ETHERNET SWITCH W/POE
AutoCAD SHX Text
EXIST. PATCH PANEL
AutoCAD SHX Text
EXISTING FIBER PANEL IN RACK
AutoCAD SHX Text
UPS
AutoCAD SHX Text
INSTALL NEW CAT-6 CABLES FROM CAMERAS AND DATA DROPS TO BASEMENT
AutoCAD SHX Text
EXISTING OPTIC FIBER CABLES
AutoCAD SHX Text
EXISTING FIBER PATCH CORD
AutoCAD SHX Text
NEW ETHERNET SWITCH W/POE
AutoCAD SHX Text
EXISTING FIBER PANEL IN RACK
AutoCAD SHX Text
EXISTING ETHERNET SWITCH W/POE
AutoCAD SHX Text
INTERIOR HARD CEILING JMF-2510
AutoCAD SHX Text
INTERIOR DROP CEILING JMF-2511
AutoCAD SHX Text
INTERIOR DROP CEILING JMF-2512
AutoCAD SHX Text
INTERIOR HARD CEILING JMF-2513
AutoCAD SHX Text
INTERIOR HARD CEILING JMF-2514
AutoCAD SHX Text
INTERIOR DROP CEILING JMF-2515
AutoCAD SHX Text
EXTERIOR WALL MOUNT JMF-2502
AutoCAD SHX Text
EXTERIOR WALL MOUNT JMF-2503
AutoCAD SHX Text
RGC-0431
AutoCAD SHX Text
LIGHT
AutoCAD SHX Text
POLE
AutoCAD SHX Text
CA
AutoCAD SHX Text
CA
AutoCAD SHX Text
RGC-0432
AutoCAD SHX Text
CABINET
AutoCAD SHX Text
CAB-006
AutoCAD SHX Text
AutoCAD SHX Text
RGC-0433
AutoCAD SHX Text
POLE
AutoCAD SHX Text
CA
AutoCAD SHX Text
RGC-0434
AutoCAD SHX Text
NEW
AutoCAD SHX Text P39
AutoCAD SHX Text P41A
AutoCAD SHX Text
CC
AutoCAD SHX Text
RGC-2504
AutoCAD SHX Text
CA
AutoCAD SHX Text
NEW CAMERA
AutoCAD SHX Text
EXISTING 12 STRAND FIBER CABLE TO CAB-005
AutoCAD SHX Text
EXISTING 12 STRAND FIBER CABLE TO CAB-007
AutoCAD SHX Text
NEW RIGID CONDUIT. 1". TRANSITION TO PVC UNDERGROUND
AutoCAD SHX Text
RISER TO EXISTING CABINET SHALL BE RIGID CONDUIT
AutoCAD SHX Text TERMINATE THE UNDERGROUND CAT-6 CABLE WITH A SURFACE MOUNT BOX. CONNECT TO EXISTING COMNET SWITCH
AutoCAD SHX Text
INSTALL EDCO POE LIGHTING SURGE PROTECTOR FOR CAMERA CABLE
AutoCAD SHX Text
8"X8"X6" PULLBOX. NEMA 3R
AutoCAD SHX Text
EGELER ADMINISTRATION BUILDING COMM ROOM 1COMM ROOM 1
AutoCAD SHX Text JACKSON BUSINESS ADMINISTRATION CELL BLOCK 5 COMM ROOM T5 COMM ROOM T5COMM ROOM T5
AutoCAD SHX Text
CAB-003
AutoCAD SHX Text
CAB-004
AutoCAD SHX Text
CAB-002
AutoCAD SHX Text
CAB-001
AutoCAD SHX Text
CAB-008
AutoCAD SHX Text
CAB-007
AutoCAD SHX Text
NA
AutoCAD SHX Text
NB
AutoCAD SHX Text
SA
AutoCAD SHX Text
SC
AutoCAD SHX Text
SB
AutoCAD SHX Text
PC MONITOR 27" LCD DISPLAY
AutoCAD SHX Text
CAT-6 CABLE TO COMM. ROOM T5
AutoCAD SHX Text
CAT-6 PATCH CABLE TO PC
AutoCAD SHX Text NOTES: : 1. INSTALL THE MONITOR MOUNT AND LCD TO THE WALL. INSTALL THE MONITOR MOUNT AND LCD TO THE WALL. INSTALL A PULL OUT MOUNT TO ALLOW MOVEMENT OF MONITORS. VERIFY LOCATION AND ELEVATION WITH OWNER PRIOR TO INSTALLATION. 2. PROVIDE AND INSTALL ALL PATCH CABLES REQUIRED FOR PROVIDE AND INSTALL ALL PATCH CABLES REQUIRED FOR CONNECTIVITY AS SHOWN IN THIS DETAIL. 3. THE CONTRACTOR SHALL SUPPLY ANY AND ALL BALUNS, THE CONTRACTOR SHALL SUPPLY ANY AND ALL BALUNS, COUPLERS ADAPTERS AND CONVERTERS THAT ARE REQUIRED FOR THE INTERCONNECTION OF THE TV TO THE CABLE. 4. REFER TO DETAIL TC101/5 AND SPECIFICATIONS FOR REFER TO DETAIL TC101/5 AND SPECIFICATIONS FOR SURFACE RACEWAY INFORMATION AND REQUIREMENTS. 5. FULLY LOAD ALL USER IDENTIFICATIONS AND SETUP THE FULLY LOAD ALL USER IDENTIFICATIONS AND SETUP THE USER LOGINS TO SPECIFIC CAMERA GROUPS AND VIEWS. 6. REFER TO FLOOR PLANS FOR CONNECTIVITY FACEPLATE REFER TO FLOOR PLANS FOR CONNECTIVITY FACEPLATE TYPES.
AutoCAD SHX Text NOTES 1. CORE THROUGH EXTERIOR WALL TO CORE THROUGH EXTERIOR WALL TO INSTALL A CONDUIT FROM THE INTERIOR TO THE EXTERIOR CAMERA BACKBOX. 2. CONDUIT SHALL BE NO SMALLER THAN CONDUIT SHALL BE NO SMALLER THAN 3/4" TRADE SIZE. INSTALL A NYLON GROMMET ON END OF CONDUIT. 3. SEAL AROUND CAMERA BASE WITH SEAL AROUND CAMERA BASE WITH CLEAR SILICONE SEALANT. SEAL AROUND CONDUIT ON EXTERIOR WITH SEALANT. 4. ATTACH CAMERA BASE TO THE ATTACH CAMERA BASE TO THE BUILDING WITH MECHANICAL CONNECTORS.
AutoCAD SHX Text C
AutoCAD SHX Text NOTES: 1. INSTALL CAMERAS RECESSED IN INSTALL CAMERAS RECESSED IN DROP CEILING OR DRYWALL CEILING. PROVIDE THE CORRECT MOUNT. 2. SEE SPECS & DRAWINGS FOR SEE SPECS & DRAWINGS FOR INFORMATION ABOUT WHO INSTALLS CAT-6 CABLE FROM COMM ROOM TO CAMERA LOCATION. 3. SECURITY CONTRACTOR SHALL SECURITY CONTRACTOR SHALL INSTALL THE PATCH CABLE FROM CAT-6 CONNECTOR TO CAMERA. SHALL BE PLENUM RATED. 4. INSTALL A LABEL ON THE INSTALL A LABEL ON THE CAMERA THAT IS VISIBLE FROM BELOW THE DROP CEILING.
AutoCAD SHX Text
SECURITY CAMERA IN DROP CEILING
AutoCAD SHX Text
TILE BRIDGE SUPPORT
AutoCAD SHX Text
CAT-6 CONNECTOR
AutoCAD SHX Text
CAT-6 CAMERA CABLE
AutoCAD SHX Text
J-HOOK ABOVE CAMERA LOCATION
AutoCAD SHX Text
CAMERA LABEL
AutoCAD SHX Text
DROP CEILING
AutoCAD SHX Text
TYPICAL INSTALLATION FOR INTERIOR CAMERA IN A DROP CEILING OR FIXED CEILING.
AutoCAD SHX Text
DROP OR FIXED CEILING
AutoCAD SHX Text C
AutoCAD SHX Text NOTES 1. INSTALL CAMERAS ON THE INSTALL CAMERAS ON THE WALL. PROVIDE THE RACEWAY AND BACKBOX. 2. SEE SPECS AND DRAWINGS SEE SPECS AND DRAWINGS FOR INFORMATION ABOUT WHO INSTALLS CAT-6 CABLE FROM COMM ROOM TO CAMERA LOCATION. 3. SECURITY CONTRACTOR SECURITY CONTRACTOR SHALL INSTALL THE PATCH CABLE FROM CAT-6 CONNECTOR TO CAMERA. SHALL BE PLENUM RATED. 4. INSTALL A LABEL ON THE INSTALL A LABEL ON THE CAMERA THAT IS VISIBLE FROM BELOW THE DROP CEILING.
AutoCAD SHX Text
SECURITY CAMERA
AutoCAD SHX Text
WALL
AutoCAD SHX Text
CAT-6 CONNECTOR
AutoCAD SHX Text
CAT-6 CAMERA CABLE
AutoCAD SHX Text
3/4" CONDUIT OR SURFACE RACEWAY. PAINT CONDUIT TO MATCH WALL COLOR
AutoCAD SHX Text INSTALL A BACKBOX ON THE WALL. MOUNT CAMERA TO THE DOUBLE-GANG BACKBOX. PROVIDE ALL PLATES TO ATTACH THE COORDINATE HEIGHT WITH OWNER PRIOR TO INSTALLATION.
AutoCAD SHX Text
CAMERA LABEL
AutoCAD SHX Text
CONDUIT PASS-THRU
AutoCAD SHX Text
BACKBOX ON WALL
AutoCAD SHX Text
RACEWAY TO CONDUIT TRANSITION
AutoCAD SHX Text
RACEWAY OR CONDUIT. SEE PLANS.
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text
CONDUIT PASS-THRU
AutoCAD SHX Text
BACKBOX ON WALL
AutoCAD SHX Text
RACEWAY TO CONDUIT TRANSITION
AutoCAD SHX Text
RACEWAY OR CONDUIT-SEE PLANS
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text
TYPICAL INSTALLATION FOR INTERIOR CAMERA ON A WALL
AutoCAD SHX Text
WALL MOUNT AT SOMEWHAT ACCESSIBLE CEILING
AutoCAD SHX Text
WALL MOUNT AT FIXED CEILING
AutoCAD SHX Text
DROP OR OPEN CEILING
AutoCAD SHX Text
DROP OR OPEN CEILING
AutoCAD SHX Text
CEILING MOUNT ON FIXED CEILING
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
WALL/CEILING MOUNT - FIXED CEILING
AutoCAD SHX Text C
AutoCAD SHX Text NOTES: 1. INSTALL CAMERAS TO THE EXTERIOR WALL. INSTALL CAMERAS TO THE EXTERIOR WALL. VERIFY HEIGHT WITH OWNER. INSTALL CONDUIT. 2. SEE SPECS & DRAWINGS FOR INFORMATION SEE SPECS & DRAWINGS FOR INFORMATION ABOUT WHO INSTALLS CAT-6 CABLE FROM COMM ROOM TO CAMERA LOCATION. 3. SECURITY CONTRACTOR SHALL INSTALL THE SECURITY CONTRACTOR SHALL INSTALL THE PATCH CABLE FROM CAT-6 CONNECTOR TO CAMERA. SHALL BE PLENUM RATED. 4. WHERE THE CAMERA LOOKS OUT FROM THE WHERE THE CAMERA LOOKS OUT FROM THE BUILDING INSTALL THE FLAT WALL MOUNT. WHERE THE CAMERA IS SHOWN LOOKING ALONG THE BUILDING THE CONTRACTOR SHALL INSTALL THE PENDANT WALL MOUNT.
AutoCAD SHX Text INSTALL A " CONDUIT THROUGH THE WALL AT THE LOCATION 34" CONDUIT THROUGH THE WALL AT THE LOCATION REQUIRED FOR PROPER CAMERA INSTALLATION. COORDINATE HEIGHT WITH OWNER PRIOR TO INSTALLATION.
AutoCAD SHX Text
SEAL AROUND CONDUIT TO WEATHER SEAL.
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
CAT-6 CAMERA CABLE
AutoCAD SHX Text
CAMERA LABEL
AutoCAD SHX Text
TYPICAL INSTALLATION FOR EXTERIOR CAMERA MOUNTED ON A WALL
AutoCAD SHX Text
CAT-6 CONNECTOR
AutoCAD SHX Text INSTALL A 3/4" CONDUIT THROUGH THE WALL AT THE LOCATION REQUIRED FOR PROPER CAMERA INSTALLATION. COORDINATE HEIGHT WITH OWNER PRIOR TO INSTALLATION.
AutoCAD SHX Text
SEAL AROUND CONDUIT TO WEATHER SEAL.
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
CAT-6 CAMERA CABLE
AutoCAD SHX Text
CAT-6 CONNECTOR
AutoCAD SHX Text
SECURITY CAMERA
AutoCAD SHX Text
CAT-6 CONNECTOR
AutoCAD SHX Text
EXTERIOR WALL MOUNT
AutoCAD SHX Text EITHER MOUNT TYPE IS APPROPRIATE. AT LOCATIONS WHERE THE CAMERA IS AIMED TO PROVIDE AN IMAGE ALONG THE EXTERIOR WALL THEN THE SECOND MOUNT TYPE (PENDANT WALL MOUNT) IS PREFERRED.
AutoCAD SHX Text
FLAT WALL MOUNT
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
PENDANT WALL MOUNT
AutoCAD SHX Text
SECURITY CAMERA
AutoCAD SHX Text
WALL
AutoCAD SHX Text
T-BAR
AutoCAD SHX Text
T-BAR
AutoCAD SHX Text
T-BAR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text GENERAL SECURITY NOTES: 1. CONTRACTOR SHALL PROVIDE ALL PATCH CABLES AT THE CAMERA AND AT CONTRACTOR SHALL PROVIDE ALL PATCH CABLES AT THE CAMERA AND AT THE COMM ROOM. 2. THE CONTRACTOR SHALL SUPPLY ANY & ALL BALUNS, COUPLERS ADAPTERS THE CONTRACTOR SHALL SUPPLY ANY & ALL BALUNS, COUPLERS ADAPTERS & CONVERTERS THAT ARE REQUIRED FOR THE INTER-CONNECTION OF ALL THE SECURITY COMPONENTS. 3. THE CAMERA CABLES SHALL TRANSPORT ALL VIDEO SIGNALS & CONTROL THE CAMERA CABLES SHALL TRANSPORT ALL VIDEO SIGNALS & CONTROL SIGNALS & POWER SIGNALS. 4. CONTRACTOR SHALL PROVIDE THE CORRECT CAMERA MOUNT BASED ON CONTRACTOR SHALL PROVIDE THE CORRECT CAMERA MOUNT BASED ON CAMERA LOCATION AND STRUCTURE AVAILABLE. PROVIDE RECESSED CAMERA MOUNTS IN DROP CEILINGS. 5. CONTRACTOR SHALL INSTALL AND CONFIGURE REMOTE VIEWING & CONTROL CONTRACTOR SHALL INSTALL AND CONFIGURE REMOTE VIEWING & CONTROL SOFTWARE ON THE FOLLOWING: -(NUMBER (X) MONITOR COMPUTERS PROVIDED AS PART OF THIS BID. -TWO (2) OWNER PC'S 6. CONTRACTOR SHALL MEET WITH THE OWNER AND DETAIL ALL THE CONTRACTOR SHALL MEET WITH THE OWNER AND DETAIL ALL THE CAPABILITIES OF THE SYSTEM. THE CONFIGURATION OF THE RECORDER AND CAMERAS SHALL BE BASED ON THESE MEETINGS WITH THE OWNER. 7. WHERE THE CAMERA IS NOT INSTALLED INTO A DROP CEILING THE WHERE THE CAMERA IS NOT INSTALLED INTO A DROP CEILING THE CONTRACTOR SHALL PROVIDE A MOUNT AND HOUSING. PROVIDE WEATHERPROOF MOUNTS ON EXTERIOR CAMERAS. 8. FOR EXTERIOR CAMERAS, THE CONTRACTOR SHALL PROVIDE A HEATER INSIDE FOR EXTERIOR CAMERAS, THE CONTRACTOR SHALL PROVIDE A HEATER INSIDE EACH CAMERA MOUNT. 9. CONTRACTOR SHALL PROVIDE THE CORRECT LENS TO EACH CAMERA BASED CONTRACTOR SHALL PROVIDE THE CORRECT LENS TO EACH CAMERA BASED ON THE INSTALLED LOCATION AND THE OWNERS REQUIREMENTS FOR THE FIELD OF VIEW. WORK WITH THE OWNER DURING INSTALLATION. 10. ALL CAMERAS SHALL CONNECT TO THE IP NETWORK SWITCH IN THE ALL CAMERAS SHALL CONNECT TO THE IP NETWORK SWITCH IN THE COMMUNICATIONS ROOM OR CABINET. CONTRACTOR SHALL WORK WITH THE OWNER ON CONFIGURATION OF THE ETHERNET SWITCH. 11. NETWORK VIDEO RECORDER(S) (NVR) ARE LOCATED IN THE ADMINISTRATION NETWORK VIDEO RECORDER(S) (NVR) ARE LOCATED IN THE ADMINISTRATION BUILDING AT THE EGELER CORRECTIONAL FACILITY AND ARE EXISTING. CONTRACTOR SHALL PROVIDE AND CONFIGURE ALL VMS AND SYSTEM SOFTWARE REQUIRED.
AutoCAD SHX Text KEYED NOTES: THE DATA NETWORK AND ALL ETHERNET SWITCHES ARE EXISTING. THE SECURITY CONTRACTOR SHALL MEET WITH THE OWNER TO CONFIRM ALL NETWORK SPECIFICATION REQUIREMENTS FOR A VLAN OR OTHER QUALITY OF SERVICE SETTINGS FOR THE CAMERA SYSTEM. FULLY CONFIGURE THE ETHERNET NETWORK. PROVIDE ALL PATCH CABLES REQUIRED FOR CONNECTION OF ALL CAMERAS AT THE CAMERA AND AT THE NETWORK SWITCH. ALL PATCH CABLES SHALL BE GREEN IN COLOR. CAT-6 CABLES FROM THE COMM ROOM TO THE CAMERA LOCATION ARE INSTALLED BY THE CABLING CONTRACTOR. INSTALL PATCH CABLES FROM OUTLET TO CAMERA. THE SERVER(S) WILL BE LOCATED IN THE EGELER ADMINISTRATION BUILDING. CONTRACTOR SHALL LOAD ALL SOFTWARE REQUIRED TO RECORD AND MANAGE ALL CAMERAS THROUGHOUT THE BUILDINGS. ADD A NEW ARCHIVER TO THE SITE. THE ARCHIVER SHALL BE SIZED TO MEET THE NEW CAMERA NEEDS PLUS 25 ADDITIONAL 1080p CAMERAS TO BE ADDED IN THE FUTURE
AutoCAD SHX Text
LIUTENANT'S OFFICE 147
AutoCAD SHX Text
SARGEANT'S OFFICE 148
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
UPS
AutoCAD SHX Text
NB
AutoCAD SHX Text
PROVIDE A FLOOR MOUNT MODEL UPS
AutoCAD SHX Text
UPS
AutoCAD SHX Text
NB
AutoCAD SHX Text
PROVIDE A FLOOR MOUNT MODEL UPS
AutoCAD SHX Text DUAL GIGABIT CONNECTIONS. PROVIDE CISCO SFP MODULES (COPPER) IN EXISTING SWITCH FOR CONNECTION
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
472/18411.JNS
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text index no.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 1065_54
AutoCAD SHX Text sheet title
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text
JACKSON, MICHIGAN
AutoCAD SHX Text
BID SET 1/18/2019
MICHIGAN STATE PRISON - JACKSON BUSINESS ADMINISTRATION SOUTHERN REGION TRANSPORTATION MOVE TO 5 BLOCK VIDEO SECURITY AND ACCESS CONTROL
UP
UPUP
UP
UP
TC901
TC901
BLOCK 5 TRANSPORTATION - FIRST FLOOR
AREA B - BLOCK 5 AND BLOCK 4N
GENERAL SECURITY
NOTES
KEYED SECURITY NOTES
C o m m t e s i g n
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O F
M
IC
H
IG
A N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
B
E L D
I N
G
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .