42220156_LRC SAROCA_DWGS.pdf
PDF 8 MB Posted
- Attached to
- LRC SAROCA Facilities
- Solicitation number
- 6100066051
- Issued by
- Lawrence County, Pennsylvania
About this file
Summary
This is a design drawings package prepared by the Commonwealth of Pennsylvania Department of Military and Veterans' Affairs for the Leadership Reaction Course (LRC) SAROCA (Small Arms Range Operations Control Area) Modernization project at Fort Indiantown Gap in Annville, Lebanon County, Pennsylvania. The project encompasses construction of four new facilities: a covered bleacher enclosure, a covered mess facility, a latrine facility, and site improvements including gravel parking areas and erosion and sediment control measures. The design documents include architectural, structural, mechanical, and electrical plans with comprehensive specifications for construction materials, methods, and quality standards. Key facilities feature pre-engineered steel structures with metal wall panels and standing seam roofing, concrete slab foundations, masonry construction for the latrine building, and integrated utilities including electrical service, HVAC systems, and plumbing infrastructure. The drawings establish construction requirements across multiple trades with detailed specifications for concrete reinforcement, structural steel connections, masonry bonding, roof framing, lightning protection systems, and site stabilization procedures.
The estimated contract values range from $800,001 to $1,000,000 for general construction, $10,001 to $20,000 for HVAC, $20,001 to $50,000 for plumbing, and $100,001 to $200,000 for electrical work. Liquidated damages are assessed at $270 per day for general construction, $40 per day for HVAC, $60 per day for plumbing, and $100 per day for electrical services. A mandatory pre-bid conference is scheduled for May 13, 2026, at 11:00 a.m. at Building 11-12 Conference Room at Fort Indiantown Gap, with attendance required to submit bids. Written questions must be submitted by May 29, 2026, at 3:30 p.m. EST, and bids are due June 8, 2026, by 2:00 p.m. The project is designated as a standard low bid procurement with Small Diverse Business (SDB) and Veteran Business Enterprise (VBE) participation goals established by the Pennsylvania Department of General Services Public Works and Office of Business Inclusion and Supplier Development. Fort Indiantown Gap operates as an access-controlled facility requiring current identification and a day pass for site visits.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 42220156_LRC SAROCA_SPECS.pdf | ||
| Instructions to Bidders DMVA - 2024.docx | DOCX document | |
| 6100066051 LRC SAROCA Facilities BDISBO SDB VBE presentation.pdf | ||
| Addendum #2.docx | DOCX document | |
| Bid docs to be returned.pdf | ||
| Pre-bid map - Area 11.pdf | ||
| Pre-bid sign in.pdf | ||
| Addendum #1.docx | DOCX document | |
| Notice to Bidders.docx | DOCX document | |
| Wage Rates.pdf | ||
| Request for Information.docx | DOCX document | |
| General Conditions to the Construction Contract DMVA 2024 v6.docx | DOCX document | |
| Administrative Procedures 2023 DMVA.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JOSH SHAPIRO, GOVERNOR
BRIGADIER GENERAL JOHN R. PIPPY, THE ADJUTANT GENERAL
ArmstrongButler
Clarion
Venango Mercer
Lawrence
Crawford
Erie
Warren
Forest
McKean
Elk
Jefferson
Clearfield
Cameron
Potter
Centre
Clinton
Beaver
Allegheny
Washington
Greene Fayette
Westmoreland
Indiana
Somerset
Cambria
Bedford
Blair
Huntingdon
Fulton Franklin
Tioga Bradford Susquehanna Wayne
Pike
Lacka- Wyoming
Luzerne
Sullivan
Lycoming
Mifflin
Snyder
Union
Northum-tour Columbia
Schuylkill
Carbon
Monroe
North-
Lehigh
Bucks
Montgomery
Philadelphia
Delaware
Juniata
Perry
Cumberland
Adams York
Lancaster
Lebanon Dauphin Berks
Chester wanna
Mon-amptonberland
NO SCALE
PROJECT NO. 42220156
LEADERSHIP REACTION COURSE (LRC) MODERNIZATION
FORT INDIANTOWN GAP WARRIOR TRAINING GROUNDS
ANNVILLE, LEBANON COUNTY, PENNSYLVANIA
COMMONWEALTH OF PENNSYLVANIA
DEPARTMENT OF MILITARY AND VETERANS' AFFAIRS
ANNVILLE, PENNSYLVANIA
CODE APPROVALS
PROJECT LOCATION MAP
VICINITY MAP
REVISIONS
DESCRIPTION DATENO.
Drawings Listed In Index:
BEA Electronic Approval DATE ________
Professional's Signature DateProfessional's Signature Date
SCALECHECKED BY
DRAWING NO.DRAWN BY DATE
DESIGN PROFESSIONALS:
OFFICE OF FACILITIES AND ENGINEERING
BUREAU OF DESIGN AND PROJECT MANAGEMENT
BUILDING 0-10, CHAPEL ROAD, FORT INDIANTOWN GAP
ANNVILLE, LEBANON COUNTY, PENNSYLVANIA
COMMONWEALTH OF PENNSYLVANIA
DEPT. OF MILITARY & VETERANS' AFFAIRS
ANNVILLE, PENNSYLVANIA 17003
PROJECT NO.:
G1.0
30 MAR. 2026
AS NOTEDK. LLOYD
J. NYE
COVER SHEET
ANNVILLE, LEBANON COUNTY, PENNSYLVANIA
FORT INDIANTOWN GAP
MODERNIZATION
LRC
42220156
DRAWING INDEX
GENERAL SITE/CIVIL BLEACHER ENCLOSURE COVERED MESS LATRINE
G1.0_COVER SHEET C1.0_EXISTING SITE PLAN BE-A1.1_PLANS & DETAILS CM-A1.1_PLANS, ELEVS. & SECTIONS LA-A1.1_PLANS, ELEVS. & DETAILS
G1.1_NOTES & SPECIFICATIONS C2.0_SITE PLAN CM-S1.1_STRUCT. PLANS & DETAILS LA-A2.1_SCHEDULES & DETAILS
C3.0_SITE NOTES & DETAILS CM-E1.1_ELEC. PLANS & DETAILS LA-S1.1_STRUCT. PLANS & DETAILS
LA-S1.2_ROOF FRAMING & DETAILS
LA-M1.1_PLANS, SCHEDS. & DETAILS
LA-E1.1_ELEC. PLANS & SCHEDULES
PROJECT
LOCATION
DRAWING NO.DRAWN BY DATE
REVISIONS
DESCRIPTION DATENO.
Professional's Signature Date
DESIGN PROFESSIONALS:
OFFICE OF FACILITIES AND ENGINEERING
BUREAU OF DESIGN AND PROJECT MANAGEMENT
BUILDING 0-10, CHAPEL ROAD, FORT INDIANTOWN GAP
ANNVILLE, LEBANON COUNTY, PENNSYLVANIA
COMMONWEALTH OF PENNSYLVANIA
DEPT. OF MILITARY & VETERAN'S AFFAIRS
ANNVILLE, PENNSYLVANIA 17003
PROJECT NO.:
CONTRACTOR SHALL FIELD VERIFY
ALL DIMENSIONS.
VARIANCE FROM CONTRACT
DOCUMENTS NOT PERMITTED
WITHOUT BUREAU OF ENGINEERING
AND ARCHITECTURE APPROVAL.
VERIFY SCALE
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
0 1
42220156
LRC
MODERNIZATION
FORT INDIANTOWN GAP
ANNVILLE, LEBANON COUNTY, PENNSYLVANIA
NOTES AND
SPECIFICATIONS
J. NYE 30 MAR. 2026
K. LLOYD AS NOTED
G1.1 abbreviationsmaterial indications drawing symbols
@ AT
& AND
ABV ABOVE
ADA AMERICANS WITH DISABILITIES ACT
ADD ADDENDUM
A.F.F. ABOVE FINISHED FLOOR
AIA AMERICAN INSTITUTE OF ARCHITECTS
ALUM ALUMINUM
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT
ASTM AMERICAN SOCIETY FOR
TESTING AND MATERIALS
ATC ACOUSTICAL TILE CEILING
APC ACOUSTICAL PANEL CEILING
BD BOARD
BDRM BEDROOM
BEL BELOW
BIT BITUMINOUS
BLDG BUILDING
BLKG BLOCKING
B.M. BENCHMARK
BOT BOTTOM
B.P. BEARING PLATE
BRG BEARING
BRK BRICK
BSMT BASEMENT
BUR BUILT-UP ROOF
B.W. BOTH WAYS
CENTERLINE
CAB CABINET
C.B. CHALKBOARD
CEM CEMENT
C.J. CONTROL JOINT
CLG CEILING
CLOS CLOSET
CLR CLEAR
C.M.U. CONCRETE MASORY UNIT
C.O. CASED OPENING
COL COLUMN
CONC CONCRETE
CORR CORRIDOR
CPT CARPET
C.T. CERAMIC TILE
D DRYER
DBL DOUBLE
DEMO DEMOLITION
DET DETAIL
DF DRINKING FOUNTAIN
DIA / Ø DIAMETER
DIM DIMENSION
DISP DISPENSER
DN DOWN
DR DINING ROOM
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
E EAST
EA EACH
EIFS EXTERIOR INSULATION AND
FINISH SYSTEM
E.J. EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENT ENTRANCE
E.P. ELECTRICAL PANEL
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EQ EQUAL
EQUIP EQUIPMENT
E.W. EACH WAY
E.W.C. ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.F.E. FINISHED FLOOR ELEVATION
F.F.L. FINISHED FLOOR LINE
FIN FINISH / FINISHED
FIXT FIXTURE
FL FLOOR
FLASH FLASHING
FLR FLOOR
F.O. FINISHED OPENING
FRTW FIRE RETARDANT TREATED WOOD
FT FEET / FOOT
FTG FOOTING
FURN FURNITURE
GA GAUGE
GALV GALVANIZED
G.B. GRAB BAR
G.C. GENERAL CONTRACTOR
G.F. GROUND FACE
GL GLASS
GYP GYPSUM
GYP BD GYPSUM BOARD
H HIGH
H.C. HOLLOW CORE
HDCP HANDICAPPED
H.M. HOLLOW METAL
HOR HORIZONTAL
HORIZ HORIZONTAL
H.P. HIGH POINT
HT HEIGHT
HVAC HEATING, VENTING AND
AIR CONDITIONING
H.W. HOT WATER
ICF INSULATED CONCRETE FORM
I.D. INSIDE DIAMETER
IN / " INCH
INFO INFORMATION
INS INSULATION
INSUL INSULATION
INT INTERIOR
J.C. JANITOR'S CLOSET
KIT KITCHEN
KP KICKPLATE
LAM LAMINATE / LAMINATED
LAV LAVATORY
LIB LIBRARY
L.P. LOW POINT
LR LIVING ROOM
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MET METAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
M.O. MASONRY OPENING
MTD MOUNTED
MTL METAL
MS METAL STUDS
N NORTH
N.I.C. NOT IN CONTRACT
NO / # NUMBER
N.R.C . NOISE REDUCTION COEFFICIENT
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OFF OFFICE
O.H. OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
P. LAM. PLASTIC LAMINATE
PART PARTITION
PERF PERFORATE
PERIM PERIMITER
PERP PERPENDICULAR
PL PLATE
PLAS PLASTIC / PLASTER
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
PR PAIR
PREFAB PREFABRICATED
PT PRESSURE TREATED
QT QUARRY TILE
QYT QUANTITY
R RISER / RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCING BAR
RECEPT RECEPTIONIST
REF REFERENCE
REFR REFRIGERATOR
REINF REINFORCEMENT
REQ REQUIRE
REQD REQUIRED
RES RESILIENT
REV REVISION
RM ROOM
R.O. ROUGH OPENING
RWC RAIN WATER CONDUCTOR
S SOUTH
S.C. SOLID CORE
SCHED SCHEDULE
SECT SECTION
SEC'Y SECRETARY
S.F. SQUARE FOOT
SHTHG SHEATHING
SHWR SHOWER
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
S.S. STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
T TREAD / TOILET
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T.B. TACK BOARD
TEMP TEMPORARY
TERR TERRAZZO
THK THICK
TOIL TOILET
T.O.P. TOP OF PLATE
T.O.S. TOP OF STEEL
TYP TYPICAL
U.D. UNIT DIMENSION
U.H. UNIT HEATER
U.L. UNDERWRITER'S LABORATORIES
U.N.O. UNLESS NOTED OTHERWISE
U.V. UNIT VENTILATOR
V.B. VAPOR BARRER / VINYL BASE
V.C.T. VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
V.I.F. VERIFY IN FIELD
V.T. VINYL TILE
V.R. VAPOR RETARDER
V.W.C. VINYL WALL COVERING
W WEST / WASHER / WIDTH / WIDE
W/ WITH
W/O WITHOUT
W.B. WHITE BOARD
W.C. WATER CLOSET
WD WOOD
W.H. WATER HEATER
WIN WINDOW
WSCT WAINSCOT
W.W.F. WELDED WIRE FABRIC
A101
SIM
A101
SIM
ROOM NAME
W?
Name Elevation
A201
SECTION CUT
DETAIL INDICATOR
FLOOR ELEVATION
TARGET
ELEVATION
INDICATOR
PARTITION TYPE
ROOM NAME/ NUMBER
WINDOW TYPE
DOOR NUMBER
COLUMN GRID
SYMBOL
CONCRETE
CONCRETE BLOCK
(C.M.U.)
BRICK
CRUSHED STONE
COMPACT EARTH
STEEL
RIGID INSULATION
EXTERIOR
INSULATION FINISH
SYSTEM (E.I.F.S.)
BATT INSULATION
WOOD BLOCKING
PLYWOOD
FINISHED WOOD
GYPSUM WALLBOARD
OR PLASTER
AutoCAD SHX Text
DESIGN CRITERIA
AutoCAD SHX Text SEE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS, SLEEVES, CURBS, PADS, INSERTS, ETC. NOT SHOWN ON STRUCTURAL DRAWINGS. BEFORE FABRICATION OF MATERIALS, COORDINATE WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL SERIES OF DRAWINGS AND SPECIFICATIONS AND PROVIDE ALL MISCELLANEOUS AND STRUCTURAL ITEMS INDICATED OR REQUIRED TO COMPLETE THE WORK.
AutoCAD SHX Text SHOP DRAWINGS SHALL BE ORIGINAL DRAWINGS, PREPARED BY CONTRACTOR, SUBCONTRACTOR, SUPPLIER OR DISTRIBUTOR. REPRODUCTION, OF ANY KIND, OF STRUCTURAL CONTRACT DOCUMENTS AS ERECTION PLANS OR DETAILS WILL NOT BE PERMITTED AND WILL BE REJECTED WITHOUT REVIEW.
AutoCAD SHX Text CONSTRUCTION DOCUMENTS CONSIST OF THESE DRAWINGS AND A SEPARATE BOOK OF SPECIFICATIONS. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY, NEITHER IS MEANT TO STAND ALONE FOR ANY PORTION OF THE WORK DESCRIBED HEREIN. ANY CONFLICT BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED IMMEDIATELY TO THE CONTRACTING OFFICER.
AutoCAD SHX Text THE STRUCTURE SHALL NOT BE CONSIDERED TO BE STABLE DURING CONSTRUCTION UNTIL ALL ELEMENTS ARE IN PLACE AND CONNECTED. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY CONSTRUCTION BRACING REQUIRED.
AutoCAD SHX Text SUBSTITUTION OF EXPANSION OR DRILLED AND GROUTED-IN ANCHORS FOR EMBEDDED ANCHORS SHOWN ON THE DRAWINGS SHALL NOT BE PERMITTED.
AutoCAD SHX Text 5.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 2.
AutoCAD SHX Text 1.
AutoCAD SHX Text
INTERNAL PRESSURE COEFF.--------
AutoCAD SHX Text
WIND LOAD IN ACCORDANCE WITH ASCE 7-98.
AutoCAD SHX Text
ALL LIVE LOADS ARE NOT REDUCIBLE.
AutoCAD SHX Text
SEISMIC DESIGN CATEGORY ---------- B
AutoCAD SHX Text
SEISMIC USE GROUP -------------- I
AutoCAD SHX Text S ------------------------- 0.07 g
AutoCAD SHX Text S ------------------------- 0.25 g
AutoCAD SHX Text
SEISMIC DESIGN PARAMETERS IN ACCORDANCE WITH IBC 2015
AutoCAD SHX Text
STAIRS AND CORRIDORS-----------
AutoCAD SHX Text
FLOORS---------------------
AutoCAD SHX Text
LIVE LOADS
AutoCAD SHX Text
BASIC WIND SPEED--------------
AutoCAD SHX Text B.
AutoCAD SHX Text s
AutoCAD SHX Text
AutoCAD SHX Text
EXPOSURE CATEGORY-------------
AutoCAD SHX Text
IMPORTANCE FACTOR-------------
AutoCAD SHX Text
LATERAL LOADS (PER SWD-AEIM):
AutoCAD SHX Text
PITCHED ROOF (MINIMUM)----------
AutoCAD SHX Text 3.
AutoCAD SHX Text A.
AutoCAD SHX Text
FLAT ROOF-------------------
AutoCAD SHX Text
%%ULOCATION
AutoCAD SHX Text 1.
AutoCAD SHX Text 90 Mph
AutoCAD SHX Text
+/- 0.55 (PARTIALLY ENCLOSED)
AutoCAD SHX Text 1.0
AutoCAD SHX Text
+/- 0.18 (ENCLOSED)
AutoCAD SHX Text C
AutoCAD SHX Text 100 psf
AutoCAD SHX Text 20 psf
AutoCAD SHX Text 100 psf
AutoCAD SHX Text 100 psf
AutoCAD SHX Text
%%UUNIFORM LIVE LOAD
AutoCAD SHX Text
OVERALL NOTES:
AutoCAD SHX Text ALL CONCRETE SHALL BE NORMAL WEIGHT AND HAVE A SPECIFIED COMPRESSIVE STRENGTH OF 4000 psi AT 28 DAYS, UNLESS OTHERWISE NOTED. CONCRETE REINFORCEMENT SHALL CONFORM WITH ASTM A615/615M, GRADE 60. REINFORCEMENT LAP SPLICES AND EMBEDMENT LENGTHS SHALL CONFORM TO TABLE A, CLASS B LENGTHS AS SHOWN ON SHEET G.1.1 UNLESS NOTED OTHERWISE. CONCRETE COVER OVER REINFORCEMENT SHALL CONFORM TO THE MINIMUMS REQUIRED BY TABLE B ON G.1.1. REINFORCEMENT DETAILING AND PLACEMENT SHALL CONFORM TO ACI318 AND ACI315. CONSTRUCTION JOINTS IN BEAMS SHALL BE PLACED IN THE CENTER OF A SPAN, WITH JOINT SPACING NOT TO EXCEED 60 ft. ALL SLAB REENTRANT CORNERS SHALL HAVE (2) #4 X 4'-0" BARS AT 45 DEGREES TO THE CORNER. FLOOR SLAB ON GRADE AND HCP TOPPING SHALL BE REINFORCED WITH SYNTHETIC POLYPROPYLENE FIBERS AT A QUANTITY OF 1.5 LBS/CY OF CONCRETE, UNLESS NOTED OTHERWISE.
AutoCAD SHX Text 5.
AutoCAD SHX Text 6.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 1.
AutoCAD SHX Text
CONCRETE NOTES:
AutoCAD SHX Text
FOUNDATION DESIGN NOTES:
AutoCAD SHX Text STRUCTURAL STEEL SHALL BE DETAILED , FABRICATED, AND ERECTED IN ACCORDANCE WITH AISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN," 1989, INCLUDING "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES."
AutoCAD SHX Text ALL BOLTS FOR BEAM CONNECTIONS SHALL BE ASTM A325 WITH A MINIMUM DIAMETER OF 3/4 in AND SHALL INCLUDE LOAD INDICATOR WASHERS, UNLESS OTHERWISE NOTED. ALL BOLTED CONNECTIONS SHALL BE BEARING TYPE CONNECTIONS WITH A MINIMUM OF TWO BOLTS.
AutoCAD SHX Text ALL SHEAR CONNECTIONS NOT DETAILED OR OTHERWISE NOTED SHALL BE STANDARD AISC WELDED OR AISC BOLTED CONNECTIONS AND SHALL HAVE SUFFICIENT CAPACITY TO SUPPORT THE END REACTION EQUAL TO ONE-HALF THE TOTAL UNIFORM LOAD CAPACITY SHOWN IN THE ALLOWABLE UNIFORM LOAD TABLES IN PART 2 OF THE AISC ALLOWABLE STRESS DESIGN MANUAL.
AutoCAD SHX Text UNLESS OTHERWISE SPECIFIED, STEEL BUILDING MEMBERS SHALL BE: W-SHAPES ASTM A992. M-, S-, AND CHANNEL SHAPES ASTM A36. SQUARE, RECTANGULAR & ROUND HSS SHAPES ASTM A500 GRADE B. ANGLES AND MISCELLANEOUS STEEL ASTM A36.
AutoCAD SHX Text 5.
AutoCAD SHX Text 4.
AutoCAD SHX Text
WELDING SHALL CONFORM WITH AWS D1.1 STRUCTURAL WELDING CODE.
AutoCAD SHX Text 3.
AutoCAD SHX Text 2.
AutoCAD SHX Text 1.
AutoCAD SHX Text
STEEL FRAMING NOTES:
AutoCAD SHX Text 2.
AutoCAD SHX Text
ROOF SNOW LOADS IN ACCORDANCE WITH ASCE 7-02 AND IBC 2015.
AutoCAD SHX Text
SNOW EXPOSURE FACTOR----------
AutoCAD SHX Text
FLAT ROOF SNOW LOAD-----------
AutoCAD SHX Text
THERMAL FACTOR---------------
AutoCAD SHX Text
SNOW LOAD IMPORTANCE FACTOR-----
AutoCAD SHX Text 1.0
AutoCAD SHX Text
VARIES (1.0 HEATED, 1.2 UNHEATED)
AutoCAD SHX Text 30 psf
AutoCAD SHX Text
1.2 (TERRAIN B)
AutoCAD SHX Text S ------------------------- 0.20 g
AutoCAD SHX Text
DS
AutoCAD SHX Text S ------------------------- 0.08 g
AutoCAD SHX Text
DI
AutoCAD SHX Text
SITE CLASS -------------------- C
AutoCAD SHX Text
SEISMIC IMPORTANCE FACTOR --------- 1.0
AutoCAD SHX Text
R (ORDINARY MASONRY SHEAR WALLS) --- 3.0
AutoCAD SHX Text
R (STEEL NOT SPECIFICALLY DETAILED) --- 3.0
AutoCAD SHX Text C -------------------------- 0.067
AutoCAD SHX Text s
AutoCAD SHX Text
1. FLOOR SLAB JOINTS (C.J. OR S.J.) SHALL BE PLACED AS SHOWN ON FOUNDATION PLANS.
AutoCAD SHX Text
2. REINFORCEMENT SHALL BE PLACED 1 1/2" FROM TOP OF NON-STRUCTURAL SLABS ON GRADE, UNLESS NOTED OTHERWISE.
AutoCAD SHX Text
3. SPACING OF JOINTS SHALL BE AS SHOWN ON THE FOUNDATION PLANS. AT THE CONTRACTOR'S OPTION, CONCRETE FLOOR SLAB ON GRADE MAY BE PLACED IN LANES. WHEN LANE PLACEMENT IS USED, CONSTRUCTION JOINTS SHALL BE USED FOR THE JOINTS BETWEEN LANES. CONTROL/SAW JOINTS SHALL BE PROVIDED ACROSS EACH LANE AT SPACING SHOWN ON PLANS.
AutoCAD SHX Text
4. ALL EXPOSED BEAMS SHALL BE CHAMFERED 3/4" ON THE EXTERIOR, EXPOSED CORNER.
AutoCAD SHX Text
5. SUBGRADE AND SELECT FILL: A. USE AN IMPERMEABLE VAPOR BARRIER (10 MIL VISQUEEN) UNDERLAIN WITH 6" OF COMPACTED DENSIFIED AGGREGATE, SUCH AS ASTM D 448 No. 57 OR No. 67. SOME LOCALIZED UNDERCUTTING MAY BE NECESSARY AND ACTUAL DEPTH OF UNDERCUT MAY VARY BASED ON SITE CONDITIONS. B. COMPACTED FILLS TO BE CONSTRUCTED BY SPREADING ACCEPTABLE SOIL IN LOOSE LAYERSNOT MORE THAN 8" THICK. ON SITE SOILS FROM EACH SITE APPEAR TO BE SUITABLE FOR RE-USE AS ENGINEERED FILL. COMPACT LIFTS TO AT LEAST 98 PERCENT OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D 698). THE UPPER 12" OF FILL BENEATH SLAB ON GRADE SHOULD BE COMPACTED TO AT LEAST 100 PERCENT OF STANDARD PROCTOR MAXIMUM DRY DENSITY.
AutoCAD SHX Text 7.
AutoCAD SHX Text 8.
AutoCAD SHX Text PRESTRESSED CONCRETE NOTES: PRESTRESSED CONCRETE NOTES: 1. MINIMUM CONCRETE 28 DAY COMPRESSIVE STRENGHT SHALL BE 5,000 PSI. MINIMUM CONCRETE 28 DAY COMPRESSIVE STRENGHT SHALL BE 5,000 PSI. 2. MINIMUM CONCRETE COMPRESSIVE STRENGHT AT PRESTRESS TRANSFER SHALL BE 3,500 MINIMUM CONCRETE COMPRESSIVE STRENGHT AT PRESTRESS TRANSFER SHALL BE 3,500 PSI. 3. NON-PRESTRESSED REINFORCING FOR PRESTRESSED ELEMENTS SHALL BE ASTM A615 NON-PRESTRESSED REINFORCING FOR PRESTRESSED ELEMENTS SHALL BE ASTM A615 GRADE 60 UNLESS OTHERWISE NOTED. 4. MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST RECOMMENDATIONS OF THE MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST RECOMMENDATIONS OF THE PRESTRESSED CONCRETE INSTITUTE AND THE ACI. 5. THE USE OF CALCIUM CHLORIDE IN ANY PRESTRESSED CONCRETE IS PROHIBITED. THE USE OF CALCIUM CHLORIDE IN ANY PRESTRESSED CONCRETE IS PROHIBITED. 6. ALL PRECAST, PRESTRESED CONCRETE MEMBERS SHALL BE SUBJECT TO REJECTION BY THE ALL PRECAST, PRESTRESED CONCRETE MEMBERS SHALL BE SUBJECT TO REJECTION BY THE ENGINEER UNLESS THEY CONFORM TO THE MANUFACTURING TOLERANCES SHOWN IN THE SPECIFICATIONS. 7. THE RAKED FINISH SPECIFIED FOR THE INTERFACE SURFACE OF PRESTRESSED MEMBERS THE RAKED FINISH SPECIFIED FOR THE INTERFACE SURFACE OF PRESTRESSED MEMBERS SHALL MEET THE REQUIREMENTS OF THE ACI 318 MEASUREMENTS OF ROUGHNESS FOR COMPOSITE CONCRETE FLEXURAL MEMBERS. 8. IT SHALL BE THE PRESTRESSED CONTRACTOR'S RESPONSIBILITY TO SUPPLY THE GENERAL IT SHALL BE THE PRESTRESSED CONTRACTOR'S RESPONSIBILITY TO SUPPLY THE GENERAL CONTRACTOR WITH ACCURATE CAMBER MEASUREMENTS OF ALL PRESTRESSED ELEMENTS DELIVERED TO THE PROJECT SITE, THE CAMBER MEASUREMENTS SHALL BE USED BY THE CONTRACTOR TO STABLISH SUPPORT ELEVATIONS OF THE PRESTRESSED ELEMENTS TO BE CONSISTENT WITH HIS RESPONSIBILITY TO PROVIDE A "LEVEL" SURFACE. 9. PRESTRESSED MEMBERS WITH DUST, MUD, AND LAITANCE ON THE INTERFACE SURFACE (TOP PRESTRESSED MEMBERS WITH DUST, MUD, AND LAITANCE ON THE INTERFACE SURFACE (TOP SURFACE) SHALL NOT BE CONSIDERED ACCEPTABLE FOR USE WITHOUT COMPLETE REMOVAL BY WASHING AND WIRE-BRUSING. 10. LIFTING DEVICES SHALL BE PLACED AS CLOSE AS POSSIBLE TO THE CENTER LINE BEARING OF THE PRESTRESSED ELEMENT. 11. PRESTRESSED MEMBERS SHALL BE DESIGNED WITHOUT MIDSPAN SHORING FOR ALL THE FOLLOWING LOADS. DEAD LOAD: WEIGHTS OF BUILDING MATERIALS AND ATTACHED EQUIPMENT AND PANELS. LIVE LOADS: REFER TO SHEET S.1.1 VERTICAL SEISMIC LOAD: PER IBC 2015.
AutoCAD SHX Text
OTHER BARS
AutoCAD SHX Text fy = 60000 psi (420 MPa), f'c = 3000 psi (21 MPa)
AutoCAD SHX Text EMBEDMENT AND CLASS A LAP (in)
AutoCAD SHX Text
CASE 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text .500
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1.250
AutoCAD SHX Text 1.375
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text .875
AutoCAD SHX Text 1.125
AutoCAD SHX Text 1.000
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text .750
AutoCAD SHX Text .625
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BAR
AutoCAD SHX Text
SIZE
AutoCAD SHX Text (in)
AutoCAD SHX Text
AutoCAD SHX Text .375
AutoCAD SHX Text
DIA.
AutoCAD SHX Text
BAR
AutoCAD SHX Text
CASE 2
AutoCAD SHX Text
TOP BAR
AutoCAD SHX Text
CASE 1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CASE 2
AutoCAD SHX Text
AutoCAD SHX Text CLASS B LAP (in)
AutoCAD SHX Text
CASE 1
AutoCAD SHX Text
AutoCAD SHX Text
CASE 2
AutoCAD SHX Text
AutoCAD SHX Text
TOP BAR
AutoCAD SHX Text
OTHER BARS
AutoCAD SHX Text
CASE 1
AutoCAD SHX Text
AutoCAD SHX Text
CASE 2
AutoCAD SHX Text
AutoCAD SHX Text
TABLE A - REINFORCEMENT TENSION LAPS AND EMBEDMENT
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text
TABLE A NOTES:
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 5.
AutoCAD SHX Text CASE 2 LENGTHS APPLY TO BEAMS AND COLUMNS WITH CONCRETE COVER LESS THAN THE BAR DIAMETER AND CLEAR BAR SPACING LESS THAN THE BAR DIAMETER AND FOR OTHER ELEMENTS WITH CONCRETE COVER LESS THAN THE BAR DIAMETER AND CLEAR BAR SPACING LESS THAN TWO TIMES THE BAR DIAMETER.
AutoCAD SHX Text CASE 1 LENGTHS APPLY TO BEAMS AND COLUMNS WITH CONCRETE COVER EQUAL OR GREATER THAN THE BAR DIAMETER, CLEAR BAR SPACING EQUAL OR GREATER THAN THE BAR DIAMETER AND WITH STIRRUPS OR TIES NOT LESS THAN THE CODE MINIMUM THROUGHOUT THE LENGTH IN THE TABLE AND FOR OTHER ELEMENTS WITH CONCRETE COVER EQUAL OR GREATER THAN THE BAR DIAMETER AND CLEAR SPACING EQUAL OR GREATER THAN TWO TIMES THE BAR DIAMETER.
AutoCAD SHX Text
CLASS "B" LAP LENGTHS APPLY WHEN ALL BARS ARE SPLICED AT THE SAME LOCATION.
AutoCAD SHX Text CLASS "A" LAP LENGTHS APPLY WHEN BAR LAPS ARE STAGGERED TO LAP HALF THE BARS AT THE SAME LOCATION.
AutoCAD SHX Text TABLE "A" PRESENTS LENGTHS OF TENSION DEVELOPMENT LENGTHS AND TENSION LAP SPLICE LENGTHS BASED ON ACI 318-02, SECTION 12.2.2.
AutoCAD SHX Text 7.
AutoCAD SHX Text 6.
AutoCAD SHX Text 9.
AutoCAD SHX Text 8.
AutoCAD SHX Text TOP BARS ARE HORIZONTAL REINFORCEMENT PLACED SO THAT MORE THAN 12" OF CONCRETE IS CAST BELOW THE REINFORCEMENT.
AutoCAD SHX Text MULTIPLY LENGTHS SHOWN BY 1.2 FOR EPOXY COATED BARS. FOR BARS WITH COVER LESS THAN 3db OR CLEAR SPACING LESS THAN 6db, USE 1.5.
AutoCAD SHX Text
MULTIPLY LENGTHS SHOWN BY 1.3 FOR LIGHTWEIGHT AGGREGATE CONCRETE.
AutoCAD SHX Text MULTIPLY LENGTHS SHOWN BY 0.87 FOR 4000 psi (28 MPa) CONCRETE.
AutoCAD SHX Text NOTE: UNLESS OTHERWISE NOTED ON DRAWINGS, CONCRETE COVER PRIMARY REINFORCEMENT, TIES, STIRRUPS AND SPIRALS SHALL COMPLY WITH LISTED VALUES. COVER SHALL COMPLY WITH REQUIREMENTS OF ACI 318M FOR ELEMENTS NOT DESCRIBED.
AutoCAD SHX Text
.75 FROM BOTT.
AutoCAD SHX Text
1.5 FROM BOTT.
AutoCAD SHX Text
SINGLE LAYER
AutoCAD SHX Text
1.5 FROM TOP
AutoCAD SHX Text
SIDE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SPOT FOOTINGS
AutoCAD SHX Text
DRILLED PIERS
AutoCAD SHX Text
COLUMNS AND PLINTHS
AutoCAD SHX Text
FORMED GRADE BEAMS
AutoCAD SHX Text
IN RIBBED MATS
AutoCAD SHX Text
ABOVE GRADE
AutoCAD SHX Text
OTHER
AutoCAD SHX Text
BEAMS
AutoCAD SHX Text
JOISTS
AutoCAD SHX Text
AutoCAD SHX Text 1.5
AutoCAD SHX Text
AutoCAD SHX Text 1.5
AutoCAD SHX Text 3.0
AutoCAD SHX Text .75
AutoCAD SHX Text 3.0
AutoCAD SHX Text 1.5
AutoCAD SHX Text 2.0
AutoCAD SHX Text
ON GRADE
AutoCAD SHX Text
SUPPORTED
AutoCAD SHX Text
OF RIBBED MATS
AutoCAD SHX Text
ON CARTON FORMS
AutoCAD SHX Text
ON CONCRETE
AutoCAD SHX Text
ON METAL DECK
AutoCAD SHX Text
INTERIOR FACES
AutoCAD SHX Text
EXTERIOR EXPOSED FACE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
WALLS
AutoCAD SHX Text
SLABS
AutoCAD SHX Text
CENTERED
AutoCAD SHX Text
CENTERED
AutoCAD SHX Text
CENTERED
AutoCAD SHX Text
CENTERED
AutoCAD SHX Text
AutoCAD SHX Text
TOP
AutoCAD SHX Text
BOTTOM
AutoCAD SHX Text 2 in FOR # 6 AND LARGER WHEN
AutoCAD SHX Text 2 in FOR # 6 AND LARGER WHEN
AutoCAD SHX Text 2 in FOR # 6 AND LARGER WHEN
AutoCAD SHX Text 3 in IF CAST ON EARTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1.5
AutoCAD SHX Text
AutoCAD SHX Text .75
AutoCAD SHX Text
AutoCAD SHX Text 1.5
AutoCAD SHX Text 1.5
AutoCAD SHX Text 1.5
AutoCAD SHX Text 3.0
AutoCAD SHX Text
AutoCAD SHX Text .75
AutoCAD SHX Text
AutoCAD SHX Text 3.0
AutoCAD SHX Text 1.5
AutoCAD SHX Text 2.0
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXPOSED TO WEATHER
AutoCAD SHX Text
EXPOSED TO WEATHER
AutoCAD SHX Text
EXPOSED TO WEATHER
AutoCAD SHX Text
1.5 in WHEN EXPOSED TO WEATHER
AutoCAD SHX Text T/4 (1.5 < T/4 < 2.5)
AutoCAD SHX Text 2 in FOR # 6 AND LARGER
AutoCAD SHX Text .75
AutoCAD SHX Text .75
AutoCAD SHX Text 1.5
AutoCAD SHX Text
AutoCAD SHX Text .75
AutoCAD SHX Text .75
AutoCAD SHX Text
AutoCAD SHX Text 1.5
AutoCAD SHX Text
TWO LAYERS
AutoCAD SHX Text
TOP BOTTOM
AutoCAD SHX Text .75
AutoCAD SHX Text
AutoCAD SHX Text 3.0
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
T = SLAB THICKNESS
AutoCAD SHX Text
OR EXPOSED TO EARTH
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
TABLE B
AutoCAD SHX Text
NON-PRESTRESSED CONCRETE FOR BUILDINGS
AutoCAD SHX Text CONCRETE COVER (in.) FOR CAST-IN-PLACE
PENNDOT STANDARD GUIDE RAIL
TREE
BENCHMARK
447.75
[450]
CONCRETE HATCH
FIRE HAYDRANT
UTILITY POLE
FLOW ARROW
BENCHMARK ELEVATION
SPOT ELEVATION
MANHOLE
WATER VALVE
ELECTRIC - UNDERGROUND
WATER LINE
SANITARY SEWER
SITE / CIVIL LEGEND
POLE MOUNTED AREA LIGHTING
FENCELINE
COMMUNICATION - UNDERGROUND
NATURAL GAS
WATERLINE CURB STOP
STORM SEWER
STORM INLET
ELECTRIC - OVERHEAD
YCO SANITARY YARD CLEAN OUT
T ELECTRICAL TRANSFORMER W/ VAULT
G GENERATOR
BENCHMARK
447.75
YCO
T
G
EXISTING PROPOSED
CONTOUR LINE
CC COMMUNICATIONS MANHOLE
E ELECTRIC PULL-BOX
BOLLARD
MH-SAN (EXG)
RIM = XXX.XX'
INV = XXX.XX'
MH-SAN (NEW)
RIM = XXX.XX'
INV = XXX.XX'
GAS VALVEG G
IRON PIN FOUND
IRON PIN SET (TO BE SET)
CONCRETE MONUMENT FOUND
CONCRETE MONUMENT SET
STONE PILE
BERNSTEIN MONUMENT
N
WOODED/BRUSH AREA
WOODED/BRUSH AREA
WOODED/BRUSH AREA
EXG. CONCRETE
BARRIERS
EXG. C
HAINLINK FENCE W
/ B
ARBED W
IRE
EXG. CHAINLINK FENCE W/ BARBED WIRE
EXG. GRAVEL PILE
EXG. TRAINING FACILITY
EXG. CONNEX
EXG.
BLEACHERS
T.B.R - B.O.
EXG. TRAINING
OBSTACLE
EXG.
BLEACHERS
T.B.R. B.O.
EXG
. EDG
E O F G
RAVEL
EXG. EDGE OF GRAVEL
EXG
. EDG
E O F G
RAVEL
EXG. E
DGE O
F G
RAVEL
EX
G.
E
DG
E
OF
G
RA
VE
L
EXG. E
DGE O
F G
RAVEL
EXG. E
DGE O
F G
RAVEL
EXG. E
DGE OF GRAVEL
EXG. E
DGE OF GRAVEL
EXG. E
DGE OF GRAVEL
EXG. EDGE OF GRAVEL
EXG. EDGE OF GRAVEL
3.0
494.000'
495.000'
4.
0'
3.
0'
2.
0'
2.0
1.
0'
0.
0'
0.
0'
9.
0'
8.0
5.
0'49
6.0
7.0
8.0
498.000'
499.000'
500.000'
499.000'
501.000'
497.000'
496.000'
495.000'
494.000'
493.000'
494.000'
495.000'
492.000'
491.000'
490.000'
490.000'
1.0
502.000'
502.000'
503.000'
EXG. ENTRANCE
TO OBSTACLE
COURSE
EXG. AREA 31
ACCESS GATE
EXG. REPELLING TOWER
EXG. STORAGE
BLDG.
EXG
. G
R
AVEL D
R
IVE
2.0
522.000'
2.
0'
1.
0'
9.
0'
8.0
517.000' 520.000'
1.0
N
SCALECHECKED BY
DRAWING NO.DRAWN BY DATE
REVISIONS
DESCRIPTION DATENO.
Professional's Signature Date
DESIGN PROFESSIONALS:
OFFICE OF FACILITIES AND ENGINEERING
BUREAU OF DESIGN AND PROJECT MANAGEMENT
BUILDING 0-10, CHAPEL ROAD, FORT INDIANTOWN GAP
ANNVILLE, LEBANON COUNTY, PENNSYLVANIA
COMMONWEALTH OF PENNSYLVANIA
DEPT. OF MILITARY & VETERAN'S AFFAIRS
ANNVILLE, PENNSYLVANIA 17003
PROJECT NO.:
CONTRACTOR SHALL FIELD VERIFY
ALL DIMENSIONS.
VARIANCE FROM CONTRACT
DOCUMENTS NOT PERMITTED
WITHOUT BUREAU OF ENGINEERING
AND ARCHITECTURE APPROVAL.
VERIFY SCALE
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
0 1
42220156
LRC
MODERNIZATION
AREA 31, FORT INDIANTOWN GAP
UNION TWP., LEBANON CO., ANNVILLE, PA 17003
SITE PLAN - EXISTING
K. LLOYD 30 MAR 2026
D. SNOW AS NOTED
C1.0
LRC - EXISTING SITE PLAN
SCALE: 1" = 20'
20' 10' 0' 20' 40'SCALE IN FEET
LOCATION MAP
SCALE: 1" = 2,000'
PROJECT SITE
GENERAL NOTES
1. THE CONTRACTOR IS REQUIRED TO SUBMIT A REQUEST FOR A
DIGGING PERMIT, THROUGH THE DIVISION OF INSTALLATION MANAGEMENT
(DIM) 717-861-6224 10 DAYS PRIOR TO STARTING EXCAVATION.
2. THE CONTRACTOR WILL PROVIDE 3 DAY NOTICE PRIOR TO ALL
UTILITY CONNECTIONS. THE CONTRACTOR WILL NOTIFY DIM
UPON COMPLETION OF THE CONNECTIONS, BUT PRIOR TO BACKFILLING.
THE CONTRACTOR WILL NOT BACKFILL ANY UTILITY CONNECTIONS
UNTIL A REPRESENTATIVE FROM DIM INSPECTS AND APPROVES THE WORK.
3. SURVEY AND REFERENCE DATUM WAS ACQUIRED FROM A GPS/RTK SURVEY
COMPLETED ON 23 JAN., 2026, STATE PLANE COORDINATE PA SOUTH, NAD83.
2" REBAR LOCATED ALONG THE EASTERN SIDE OF THE LAND FILL SITE,
NORTHING = 409463.175', EASTING = 2304116.370', ELEVATION = 497.387' (U.S.
SURVEY FEET).XXXXXXXX
KEY MAP
SCALE: 1" = 500'
TOWER SITE
LRC SITE
TOWER - EXISTING SITE PLAN
SCALE: 1" = 20'
20' 10' 0' 20' 40'SCALE IN FEET
PENNDOT STANDARD GUIDE RAIL
TREE
BENCHMARK
447.75
[450]
CONCRETE HATCH
FIRE HAYDRANT
UTILITY POLE
FLOW ARROW
BENCHMARK ELEVATION
SPOT ELEVATION
MANHOLE
WATER VALVE
ELECTRIC - UNDERGROUND
WATER LINE
SANITARY SEWER
SITE / CIVIL LEGEND
POLE MOUNTED AREA LIGHTING
FENCELINE
COMMUNICATION - UNDERGROUND
NATURAL GAS
WATERLINE CURB STOP
STORM SEWER
STORM INLET
ELECTRIC - OVERHEAD
YCO SANITARY YARD CLEAN OUT
T ELECTRICAL TRANSFORMER W/ VAULT
G GENERATOR
BENCHMARK
447.75
YCO
T
G
EXISTING PROPOSED
CONTOUR LINE
CC COMMUNICATIONS MANHOLE
E ELECTRIC PULL-BOX
BOLLARD
MH-SAN (EXG)
RIM = XXX.XX'
INV = XXX.XX'
MH-SAN (NEW)
RIM = XXX.XX'
INV = XXX.XX'
GAS VALVEG G
IRON PIN FOUND
IRON PIN SET (TO BE SET)
CONCRETE MONUMENT FOUND
CONCRETE MONUMENT SET
STONE PILE
BERNSTEIN MONUMENT
N
WOODED/BRUSH AREA
WOODED/BRUSH AREA
WOODED/BRUSH AREA
EXG. CONCRETE
BARRIERS
EXG. C
HAINLINK FENCE W
/ B
ARBED W
IRE
EXG. CHAINLINK FENCE W/ BARBED WIRE
EXG. GRAVEL PILE
EXG. TRAINING FACILITY
EXG. CONNEX
EXG.
BLEACHERS
T.B.R - B.O.
EXG. TRAINING
OBSTACLE
EXG.
BLEACHERS
T.B.R. B.O.
EXG
. EDG
E O F G
RAVEL
EXG. EDGE OF GRAVEL
EXG
. EDG
E O F G
RAVEL
EXG. E
DGE O
F G
RAVEL
EX
G.
E
DG
E
OF
G
RA
VE
L
EXG. E
DGE O
F G
RAVEL
EXG. E
DGE O
F G
RAVEL
EXG. E
DGE OF GRAVEL
EXG. E
DGE OF GRAVEL
EXG. E
DGE OF GRAVEL
EXG. EDGE OF GRAVEL
EXG. EDGE OF GRAVEL
NEW COVERED
BLEACHER FACILITY
F.F.E. 499.00'
3.0
494.000'
495.000'
4.
0'
3.
0'
2.
0'
2.0
1.
0'
0.
0'
0.
0'
9.
0'
8.0
5.
0'49
6.0
7.0
8.0
498.000'
499.000'
500.000'
499.000'
501.000'
497.000'
496.000'
495.000'
494.000'
493.000'
494.000'
495.000'
492.000'
491.000'
490.000'
490.000'
1.0
NEW COVERED
BLEACHER FACILITY
F.F.E. = 493.50'
NEW COVERED
MESS FACILITY
F.F.E. 500.00'
NEW LATRINE
FACILITY
F.F.E. 503.00'
502.000'
503.000'
12" FILTER FABRIC SOCK
TOPSOIL PILE
12" FILTER FABRIC SOCK
TOPSOIL PILE
LOD LOD
LO
D
LO
D
LOD
LOD
LO
D
LOD
TOPSOIL PILE
LOD LOD
LO
D
LOD
TOPSOIL PILE
LO
D
LOD
LO
D
EXG. ENTRANCE
TO OBSTACLE
COURSE
[5
[4
[4
[493']
EXG. AREA 31
ACCESS GATE
NEW 80' x 24' GRAVEL PARKING AREA -
EXCAVATE AND REMOVE FROM SITE EXG.
8" MATERIAL AND REPLACE WITH SINGLE
LAYER OF PENNDOT CLASS 4-C
GEOTEXTILE FABRIC AND 8" OF AASHTO #3,
ROLLED FIRM BUT NOT COMPACTED. NEW
GRAVEL WILL FOLLOW EXISTING GRADE.
LO
D
LO
D
LOD
LOD
LO
D
LOD
LOD
NEW COVERED
BLEACHER FACILITY
OPEN NORTH
F.F.E. 520.50'
EXG. REPELLING TOWER
EXG. STORAGE
BLDG.
12" FILTER FABRIC SOCK
EXG
. G
R
AVEL D
R
IVE
CONSTRUCTION
ENTRANCE C.3.0
TOPSOIL PILE
LOD
LOD
LOD
LOD
2.0
522.000'
2.
0'
1.
0'
9.
0'
8.0
517.000'
516.000'
520.000'
1.0
519.000'
[519']
[518']
N
SCALECHECKED BY
DRAWING NO.DRAWN BY DATE
REVISIONS
DESCRIPTION DATENO.
Professional's Signature Date
DESIGN PROFESSIONALS:
OFFICE OF FACILITIES AND ENGINEERING
BUREAU OF DESIGN AND PROJECT MANAGEMENT
BUILDING 0-10, CHAPEL ROAD, FORT INDIANTOWN GAP
ANNVILLE, LEBANON COUNTY, PENNSYLVANIA
COMMONWEALTH OF PENNSYLVANIA
DEPT. OF MILITARY & VETERAN'S AFFAIRS
ANNVILLE, PENNSYLVANIA 17003
PROJECT NO.:
CONTRACTOR SHALL FIELD VERIFY
ALL DIMENSIONS.
VARIANCE FROM CONTRACT
DOCUMENTS NOT PERMITTED
WITHOUT BUREAU OF ENGINEERING
AND ARCHITECTURE APPROVAL.
VERIFY SCALE
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
0 1
42220156
LRC
MODERNIZATION
AREA 31, FORT INDIANTOWN GAP
UNION TWP., LEBANON CO., ANNVILLE, PA 17003
SITE/E&S PLAN - NEW
K. LLOYD 30 MAR 2026
D. SNOW AS NOTED
C2.0
LRC SAROCA - SITE PLAN
SCALE: 1" = 20'
20' 10' 0' 20' 40'SCALE IN FEET
LOCATION MAP
SCALE: 1" = 2,000'
PROJECT SITE
CONSTRUCTION NOTES
1. THE CONTRACTOR IS REQUIRED TO RETURN THE LIMIT OF DISTURBANCE
AREA TO ITS ORIGINAL CONDITION, PRIOR TO COMPLETION OF PROJECT,
ENSURING CROSS-SECTIONS OF TOPSOIL, GRAVEL AND PAVED AREAS
MATCH DEPTHS, TYPES OF MATERIAL AND SPECIFICATIONS.
2. THE CONTRACTOR WILL BE ABLE TO REMOVE AND DUMP CLEAN FILL AT A
LOCATION ON FT. INDIANTOWN GAP, APPROXIMATELY 2 MILES FROM
PROJECT SITE.
3. ALL SITE MATERIALS WILL BE IN ACCORDANCE WITH PENNDOT
SPECIFICATION 408, MOST CURRENT VERSION AS OF 1 APRIL 2025
4. ALL WORK ASSOCIATED WITH THE INSTALLATION OF ELECTRICAL CONDUIT,
CONDUCTORS AND ALL OTHER ASSOCIATED ELECTRICAL WORK, TO
INCLUDE, BUT NOT BE LIMITED TO, TRENCHING, BACKFILLING, FINE
GRADING, SEEDING , ETC..., IS THE RESPONSIBILITY OF THE .4 ELECTRICAL
CONTRACTOR.
5. ALL SITE WORK, REGARDLESS OF POINT CONTRACT, SHALL ADHERE TO THE
NOTES AND DETAILS HEREIN AND BE IN ACCORDANCE WITH THE DIVISION 31
AND 32 SPECIFICATIONS.
TOWER SAROCA - SITE PLAN
SCALE: 1" = 20'
20' 10' 0' 20' 40'SCALE IN FEET
KEY MAP
SCALE: 1" = 500'
TOWER SITE
LRC SITE
6. A CONSTRUCTION ENTRANCE WILL ONLY BE REQUIRED AT THE TOWER SITE
DUE TO LOCATION OF COVERED BLEACHER.
7. SEE NOTES ON SHEET C.3.0 FOR APPLICATION OF SEEDING, MULCHING AND
FERTILIZER.
12" COMPOST
- L.O.D. - LIMIT OF
DISTURBANCE
E&S LEGEND
FILTER SOCK C.3.0
THE AREA OF DISTURBANCE
TOWER = 4,937 SF, 0.11 AC
LATRINE = 2,614 SF, 0.06 AC.
COVERED MESS = 3,252 SF, 0.07 AC.
LRC BLEACHER = 2,364 SF, 0.05 AC.
OBSTACLE COURSE BLEACHER = 2,704 SF, 0.06 AC.
GRAVEL PARKING AREA = 3,250 SF, 0.07 AC.
IMPERVIOUS AREA INCREASE = 2,739 SF, 0.06 AC
CONST. ENTRANCE
C.3.0
1-0 GENERAL NOTES
1. At least 10 days before starting any earth disturbance activities, the contractor shall invite all maintenance personnel involved in those activities, the landowner, all appropriate municipal officials, the erosion and sedimentation control plan preparer, and a representative of the Lebanon Conservation District at
717-277-5275 to schedule an on-site pre-construction meeting.
Also, at least 3 days before starting any earth disturbance activities, the contractor shall notify the Pennsylvania One Call
System Inc. at 1-800-242-1776 for buried utilities location.
2. Before implementing any revisions to the approved erosion and sediment control plan or revisions to other plans which may affect the effectiveness of the approved E&S control plan, the contractor receive written approval of the revisions from the Lebanon
Conservation District.
3. The contractor shall remove from the site, recycle or dispose of all waste materials (tree stumps, brush etc.) in accordance with the
Department's Solid Waste Management Regulations at 25 PA
Code 260.1 et seq., 271.1 e. seq. and 287.1 et seq.
4. Before disposing of soil or receiving borrow for the site, the contractor must assure that each spoil or borrow area has an erosion and sediment control plan approved by the Lebanon
Conservation District, and which is being implemented and maintained according to Chapter 102 regulations. The contractor shall also notify the Lebanon Conservation District in writing of all receiving spoil and borrow areas when they have been identified.
5. Only limited disturbance will be permitted to provide access to construct construction BMPs.
6. Erosion and sedimentation controls must be constructed, stabilized, and functional before site disturbance within the tributary areas of those controls.
7. After final site stabilization has been achieved, temporary erosion and sedimentation controls must be removed. Areas disturbed during removal of the controls must be stabilized immediately.
8. At the end of each working day, any sediment tracked or conveyed onto a public roadway will be removed and redeposited onto the construction site. Removal can be completed through use of mechanical or hand tools, but must never be washed off the road by use of water.
9. Sediment removed from E&SPC controls & facilities shall be disposed of in landscaped areas outside of steep slopes, wetlands, floodplains or drainage swales and immediately stabilized, or placed in topsoil stockpiles.
10. All pumping of sediment laden water shall be through a dirt bag filtration device, or equivalent sediment removal facility, over non-disturbed vegetated areas. Discharge points should be established to provide for maximum distance to active waterways.
11. Should unforeseen erosive conditions develop during construction, the contractor shall take immediate action to remedy such conditions and to prevent damage to adjacent properties as a result of increased runoff and/or sediment displacement.
Stockpiles of wood chips, hay bales, crushed stone and other mulches shall be held in readiness to deal immediately with emergency problems of erosion.
12. The contractor is advised to become thoroughly familiar with the provisions of the Appendix 64, Erosion Control Rules and
Regulations, Title 25, Part 1, Department of environmental
Protection, Subpart C, Protection of Natural Resources, Article III, Water Resources, Chapter 102, Erosion Control.
13. A copy of this erosion and sedimentation control report and plans must be posted at the construction site.
14. Failure to correctly install sediment control facilities or failure to prevent sediment laden runoff from leaving the construction site or failure to take corrective actions to immediately resolve failures of sediment control facilities may result in administrative, civil and/or criminal penalties being instituted by the Pennsylvania
Department of Environmental Protection as defined in Section 602 of the Clean Streams Law of Pennsylvania. The Clean Streams
Law provides for up to $10,000 per day in civil penalties, up to
$10,000 in summary criminal penalties, and up to $25,000 in misdemeanor criminal penalties for each violation.
2-0 STABILIZATION NOTES
1. Stockpile heights must not exceed 35'. Stockpile slopes must be
2:1 or flatter.
2. Upon completion of an earth disturbance activity or any stage or phase of an activity, the contractor shall stabilize immediately the disturbed areas to protect from accelerated erosion. During non-germinating periods, mulch must be applied at the specified rates. Disturbed areas which are not at finished grade and which will be redisturbed within 1 year may be stabilized in accordance with temporary seeding specifications. Disturbed areas, which are either at finished grade or will not be redisturbed within 1 year, must be stabilized in accordance with permanent seeding specifications.
3. Stockpiles must be stabilized immediately.
4. Hay or straw mulch must be applied at rates of at least 3.0 tons per acre.
5. Until the site has achieved final stabilization the contractor shall properly implement, operate and maintain all the best management practices. Maintenance shall include inspections of all erosion and sedimentation control after each runoff event and on a weekly basis. All preventative and remedial maintenance work, including clean out, repair, replacement, regrading, reseeding, remulching, and renetting, must be performed immediately.
6. An area shall be considered to have achieved final stabilization when it has a minimum uniform 70% perennial vegetative cover or other permanent non-vegetative cover with a density sufficient to resist accelerated surface erosion and subsurface characteristics sufficient to resist sliding or other movements.
7. Mulch with mulch control netting or erosion control blankets must be installed on all slopes greater than 3:1.
2-1 COMPOST FILTER SOCK
1. Compost sock should be placed parallel to contours with both ends of the sock extended upslope at a 45 degree angle to the rest of the sock to prevent end-arounds.
2. Socks placed on earthen slopes should be anchored with stakes driven through the center of the sock or immediately down slope of the sock as per detail.
3. Any section of compost sock, which has been undermined or topped, must be immediately replaced.
3-0 CONSTRUCTION SEQUENCE NOTES
1. All earth disturbance activities shall proceed in accordance with the following sequence. Each stage shall be completed in compliance with Chapter 102 regulations before any following stage is initiated. Clearing and grubbing shall be limited only to those areas described in each stage.
2. Flag the limit of disturbance.
3. Install compost filter sock as per plan.
4. Mobilize construction equipment.
5. Clear and grub the site within the limits of disturbance.
6. Strip topsoil and stockpile and stabilize.
7. Excavate for structures and gravel parking area.
8. After site is stabilized, remove temporary BMP's and stabilize.
4.0 GROUND COVER
4.1 Temporary Seeding
1. All grass areas disturbed by the work of this Project shall be seeded as follows:
2. Temporary seeding shall be done in areas where active work will not be performed for twenty days (20). Temporary seeding shall be done immediately after work ceases.
3. Apply agricultural lime and fertilizer as follows for temporary seeding:
3.1. Agricultural Lime -- 50 pounds per 1,000 square feet
3.2. Fertilizer -- 12 pounds per 1,000 square feet
4. Fertilizer shall be a commercial type 10-20-20.
5. Temporary seed mixture Annual Ryegrass -- 1 pound per 1,000 square feet.
6. All temporary seeding shall be mulched. Temporary seeding shall be watered as required to develop cover.
7. Mulch shall be straw, shall be clean and free from noxious weeds, and shall be applied at the rate of 140 pounds per 1,000 square feet.
4.2 Permanent Seeding
1. Permanent seeding shall take place in all disturbed areas as follows:
2. Fertilization: The following shall be spread and worked into the topsoil to a depth of 3 to 4 inches.
2.1. Agricultural Lime - 275 pounds per 1,000 square feet
2.2. Fertilizer - 25 pounds per 1,000 square feet
3. The fertilizer shall be a commercial type 10-20-20.
4. Note: If agricultural lime and fertilizer have been applied previously to the ground where the permanent seed is to be applied, the lime and fertilizer rates shall be reduced by the amount by what has been applied previously.
5. Permanent Seed Mixture: The following seed mixtures shall be applied as follows:
6. FTIG ITAM Mix (requires proper legume inoculants)
6.1. 10% Annual Ryegrass
6.2. 25% Perennial Regrass
6.3. 20% Medium Ryegrass
6.4. 10% White Ladino Clover
6.5. 10% White Dutch Clover
6.6. 10% Vernal Alfalfa
6.7. 10% Norcen Birdsfoot Trefoil
6.8. 5% Crimson
7. PENNDOT Formula L Low Grow Mix
7.1. 35% Creeping Red Fescue
7.2. 27.5% Defiant Hard Fescue
7.3. 27.5% Stonehenge Fescue
7.4. 10% Annual Ryegrass
8. FTIG Legume Mix( plant with Low Grow at rate 10#/acre, requires inoculant)
8.1. 20% White Ladino Clover
8.2. 10% Medium Red Clover
8.3. 10% Mammoth Red Clover
8.4. 10% White Dutch Clover
8.5. 10% Alsike Clover
8.6. 20% Vernal Alfalfa
8.7. 10% Norcen Birdsfoot Trefoil
8.8. 10% Crimson Clover
8.9. *All mixtures given above are for PLS - Pure Live Seed 100%. To calculate PLS, the percentage of pure seed is multiplied by the percentage of germination, and the product is divided by 100. (85% pure seed x 72% germination) divided by 100 = 61% PLS. To determine how much seed to plant, divide the percentage into 100. Example: 100 divided by 61 = 1.63. Thus, every pound of seed mixture called for should then be 1.63 lbs.
9. Mulch: Apply mulch to all permanently seeded areas.
9.1. Materials: Straw, air-dried and free from undesirable seeds and course materials. Application: 140 pounds per 1,000 square feet.
5.0 MAINTENANCE PROGRAM
5.1 Emergency Erosion Protection
1. If erosion does occur, the contractor shall repair and reseed those areas or use other stabilization methods as required. The contractor shall use jute, wood fiber, or other tie down filter netting on top of the new seed as required, regardless of the slope of the land.
2. Mulched areas shall be checked weekly and immediately after severe storms for damage, until the mulching is no longer necessary for protection against erosion. Damaged portions of the mulch or tie down materials shall be repaired as soon as discovered.
5.2 Periodic Inspection Program
1. The contractor will regularly inspect the Project's erosion and sedimentation controls during the entire active construction stages. The inspections will be performed weekly or after all runoff events and the inspections shall be documented and records of repairs keep on site. The contractor will be responsible for the installation, operation, maintenance, and removal of all erosion and sedimentation controls. All preventative and remedial maintenance work, including clean out repair, replacement, regrading, reseeding, remulching, and renetting must be performed immediately. Sediment that has been trapped by the silt soxx will be removed as required, and in all cases, before the accumulation has reached half the height of the BMP. Compost filter sock will be re-anchored, repaired, or replaced as necessary.
All other controls will be inspected on the same schedule. If erosion and sediment control BMPs fail to perform as expected, replacement BMPs, or modification of those installed will be required.
5.3 Removal of Controls and Continuing Maintenance
1. All required temporary erosion and sedimentation controls shall remain in place and be maintained until the area they protect has been stabilized.
2. An area shall be considered to have achieved final stabilization when it has a minimum uniform 70% perennial vegetative cover or other permanent non-vegetative cover with a density sufficient to resist accelerated surface erosion and subsurface characteristics sufficient to resist sliding or other movements.
AREA TO BE PROTECTED
2" x 2" WOODEN STAKE
WORK AREA
SIZE - SEE E&S PLAN
SECTION
WATER FLOW
WORK AREA
AREA TO BE PROTECTED
STAKE ON 10' LINEAL SPACING
FILTREXX COMPOST SILTSOXX
OR APPROVED EQUAL
PLAN
MAINTENANCE NOTES:
1. THE CONTRACTOR SHALL MAINTAIN THE SEDIMENT CONTROL IN A
FUNCTIONAL CONDITION AT ALL TIMES AND IT SHALL BE ROUTINELY INSPECTED.
2. IF THE SEDIMENT CONTROL HAS BEEN DAMAGED, IT SHALL BE REPAIRED, OR
REPLACED IF BEYOND REPAIR.
3. THE CONTRACTOR SHALL REMOVE SEDIMENT AT THE BASE OF THE UPSLOPE SIDE
OF THE SEDIMENT CONTROL WHEN ACCUMULATION HAS REACHED 12 OF THE
EFFECTIVE HEIGHT OF THE SEDIMENT CONTROL, OR AS DIRECTED BY THE
ENGINEER. ALTERNATIVELY, A NEW SEDIMENT CONTROL CAN BE PLACED ON TOP
OF AND SLIGHTLY BEHIND THE ORIGINAL ONE CREATING MORE SEDIMENT
STORAGE CAPACITY WITHOUT SOIL DISTURBANCE.
4. SEDIMENT CONTROL SHALL BE MAINTAINED UNTIL DISTURBED AREA ABOVE THE
DEVICE HAS BEEN PERMANENTLY STABILIZED AND CONSTRUCTION ACTIVITY HAS
CEASED.
5. THE FILTERMEDIA WILL BE DISPERSED ON SITE ONCE DISTURBED AREA HAS BEEN
PERMANENTLY STABILIZED, CONSTRUCTION ACTIVITY HAS CEASED, OR AS
DETERMINED BY THE ENGINEER.
6. FOR LONG-TERM SEDIMENT AND POLLUTION CONTROL APPLICATIONS, SEDIMENT
CONTROL CAN BE SEEDED AT THE TIME OF INSTALLATION TO CREATED A
VEGETATIVE FILTERING SYSTEM FOR PROLONGED AND INCREASED FILTRATION OF
SEDIMENT AND SOLUBLE POLLUTANTS (CONTAINED VEGETATIVE FILTER STRIP).
THE APPROPRIATE SEED MIX SHALL BE DETERMINED BY THE ENGINEER.
GEOTEXTILE MATERIAL
PROFILE
MAINTENANCE:
GROUND
EXISTING
#1 ROCK
A.A.S.H.T.O.
CLASS 4
EXG. ASPHALT ROAD
PLAN
EXG. ASPHALT ROAD/PARKING LOT
A.A.S.H.T.O. #1 ROCK
EXISTING GROUND
PROVIDE APPROPRIATE TRANSITION
BETWEEN STABILIZED CONSTRUCTION
ENTRANCE AND PUBLIC RIGHT-OF-WAY
VEHICLES AND EQUIPMENT MAY NEITHER ENTER DIRECTLY TO NOR
EXIT DIRECTLY FROM THE SITE WITHOUT PASSING THRU A ROCK
CONSTRUCTION ENTRANCE.
REMOVE TOPSOIL PRIOR TO INSTALLATION OF ROCK CONSTRUCTION
ENTRANCE. EXTEND ROCK OVER FULL WIDTH OF ENTRANCE.
RUNOFF SHALL BE DIVERTED FROM ROADWAY TO A SUITABLE
SEDIMENT REMOVAL BMP PRIOR TO ENTERING ROCK CONSTRUCTION
ENTRANCE.
MOUNTABLE BERM SHALL BE INSTALLED WHEREVER OPTIONAL
CULVERT PIPE IS USED AND PROPER PIPE COVER AS SPECIFIED BY
MANUFACTURER IS NOT OTHERWISE PROVIDED. PIPE SHALL BE SIZED
APPROPRIATELY FOR SIZE OF DITCH BEING CROSSED.
ROCK CONSTRUCTION ENTRANCE THICKNESS WILL BE CONSTANTLY
MAINTAINED TO THE SPECIFIED DIMENSIONS BY ADDING ROCK. A
STOCKPILE OF ROCK MATERIAL WILL BE MAINTAINED ON THE SITE FOR
THIS PURPOSE. ALL SEDIMENT DEPOSITED ON PAVED ROADWAYS
SHALL BE REMOVED AND RETURNED TO THE CONSTRUCTION SITE
IMMEDIATELY. IF EXCESSIVE AMOUNTS OF SEDIMENT ARE BEING
DEPOSITED ON ROADWAY, EXTEND LENGTH OF ROCK CONSTRUCTION
ENTRANCE BY 50' INCREMENTS UNTIL CONDITION IS ALLEVIATED OR
INSTALL WASH RACK. WASHING THE ROADWAY OR SWEEPING THE
DEPOSITIS INTO ROADWAY DITCHES, SEWERS, CULVERTS, OR OTHER
DRAINAGE COURSES IS NOT ACCEPTABLE.
50' (MIN.)
M
IN
3'
8" (M
IN
.) MOUNTABLE
BERM (6" MIN.)
PIPE AS
NECESSARY
** MOUNTABLE BERM USED TO PROVIDE PROPER COVER FOR PIPE. **
SCALECHECKED BY
DRAWING NO.DRAWN BY DATE
REVISIONS
DESCRIPTION DATENO.
Professional's Signature Date
DESIGN PROFESSIONALS:
OFFICE OF FACILITIES AND ENGINEERING
BUREAU OF DESIGN AND PROJECT MANAGEMENT
BUILDING 0-10, CHAPEL ROAD, FORT INDIANTOWN GAP
ANNVILLE, LEBANON COUNTY, PENNSYLVANIA
COMMONWEALTH OF PENNSYLVANIA
DEPT. OF MILITARY & VETERAN'S AFFAIRS
ANNVILLE, PENNSYLVANIA 17003
PROJECT NO.:
CONTRACTOR SHALL FIELD VERIFY
ALL DIMENSIONS.
VARIANCE FROM CONTRACT
DOCUMENTS NOT PERMITTED
WITHOUT BUREAU OF ENGINEERING
AND ARCHITECTURE APPROVAL.
VERIFY SCALE
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
0 1
42220156
LRC
MODERNIZATION
AREA 31, FORT INDIANTOWN GAP
UNION TWP., LEBANON CO., ANNVILLE, PA 17003
SITE/E&S
NOTES & DETAILS
K. LLOYD 30 MAR 2026
D. SNOW AS NOTED
C3.0
C.3.0
1 FILTER SOCK (TYP.)
NOT TO SCALE
C.3.0
2 CONSTRUCTION ENTRANCE (TYP.)
NOT TO SCALE
1 2 3
A
B
34'-4"
4"
17'-2" 17'-2"
16'-10" 4"16'-10"
'-0
" 6" CONC. SLAB W/ 6x6-W2.9xW2.9 W.W.F.
CONTROL JOINT
F1 F1F1
F1 F1 F110 A1.2
'-8
SL
AB
35'-0" (SLAB)
P1 P1 P1
P1 P1 P1
8" C.M.U. FOUNDATION WALL
(4)ANCHOR BOLTS, AB-1
(6 PLACES) FOR ANCHOR BOLT
LOCATIONS, SEE NUCOR
BUILDING SYSTEMS' DRAWINGS.
1 2 3
A
B
34'-4"
4"
17'-2" 17'-2"
16'-10" 4"16'-10"
'-0
'-8
SL
AB
35'-0" (SLAB)
15'-0" WIDE 10 ROW BLEACHERS ON
BOTTOM RAILS - BOLT TO SLAB
D.S. & SPLASH
BLOCK TYP.
OPERABLE LOUVER
(LOCATE IN FIELD)
OPERABLE LOUVER
(LOCATE IN FIELD)
2'-0"x3'-0"
ACCESS PANEL
2'-0"2'-0"
15'-0" WIDE 10 ROW BLEACHERS ON
BOTTOM RAILS - BOLT TO SLAB
6" CONC. SLAB ON 4"
STONE BASE
3'- 0"
M
IN
. B
EL
OW
G
RA
DE
LINE OF PEDESTAL &
FOOTING BEYOND)
8" C.M.U. ( FULLY
GROUTED )
2'-0"
HORIZ. JOINT REINFOR.
#4 BAR @ 48" O.C.
8"
(3)#4 BARS
#4 TIES @ 24" O.C.
COLUMN BEYOND METAL WALL PANEL
METAL WALL PANEL
BASE TRIM
4" FABRIC WRAPPED
DRAIN TILE W/ 6"
STONE BASE & 12"
STONE COVER
SEE FOOTING SCHEDULE FOR SIZE OF
FOUNDATION & REINFORCING
A1.1
℄ COLUMN, PEDESTAL & FOOTING
TOP/FLOOR
PEDESTAL (SEE SCHEDULE
FOR REINFORCEMENT)
THIS TIE REQUIRED
WHEN 6 VERTICAL BARS
ARE SPECIFIED
TIE
SAWED JOINT TO
BE FILLED W/
JOINT SEALANT
T/
T
1/8" MIN.
1/4" MAX.
W.W.F. @ MID-DEPTH
OF SLAB
ASTM F1554
ANCHOR BLOT
P E
D
BASE PLATE
GROUT
TOP OF CONC.
'-0
34'-8"
'-0
7'-6"
GUTTER
(6"x6")
D.S.
(4"x4")
7'-6"
'-0
30"x30" OPERABLE
LOUVER
30"x30" OPERABLE
LOUVER
24 GA. STANDING SEAM ROOF
PANELS - COLOR TO BE
SELECTED BY GOVERNMENT
DESIGN PROFESSIONAL
D.S.
(4"x4")
D.S.
(4"x4")
34'-8"
'-0
STEEL BEAM STEEL BEAM STEEL BEAM
HORIZONTAL SUPPORT
STEEL - PER
MANUFACTURER (TYP.)
HORIZONTAL SUPPORT
STEEL - PER
MANUFACTURER (TYP.)
REAR METAL WALL PANELS -
INTERIOR COLOR TO BE
WHITE (TYP.)
'-0
'-0
20'-0"
18"
24 GA. METAL WALL
PANELS (TYP.) - COLOR TO BE
SELECTED BY GOVERNMENT
DESIGN PROFESSIONAL
'-0
'-0
20'-0"
18"
24 GA. METAL WALL
PANELS (TYP.) - COLOR TO BE
SELECTED BY GOVERNMENT
DESIGN PROFESSIONAL
SCALECHECKED BY
DRAWING NO.DRAWN BY DATE
REVISIONS
DESCRIPTION DATENO.
Professional's Signature Date
DESIGN PROFESSIONALS:
DEPARTMENT OF MILITARY AND VETERANS AFFAIRS
BUREAU OF DESIGN AND PROJECT MANAGEMENT
BLDG. 0-10, FORT INDIANTOWN GAP
ANNVILLE, LEBANON COUNTY, PENNSYLVANIA
COMMONWEALTH OF PENNSYLVANIA
DEPT. OF MILITARY & VETERAN'S AFFAIRS
ANNVILLE, PENNSYLVANIA
PROJECT NO.:
CONTRACTOR SHALL FIELD VERIFY
ALL DIMENSIONS.
VARIANCE FROM CONTRACT
DOCUMENTS NOT PERMITTED
WITHOUT BUREAU OF ENGINEERING
AND ARCHITECTURE APPROVAL.
VERIFY SCALE
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
0 1
J. NYE 30 MAR. 2026
K. LLOYD AS NOTED
BE - A1.1
LRC
MODERNIZATION
FORT INDIANTOWN GAP
ANNVILLE, LEBANON COUNTY, PA 17003
PLANS & DETAILS
42220156
F1
MARK FOOTING SIZE
REINFORCING
BOTTOM BARS
FOOTING SCHEDULE
5'-0" x 5'-0"
FOOTING DEPTH
12"
TOP BARS
#5 @ 12 O.C. #4 @ 12" O.C.
P1
MARK PEDESTAL SIZE
REINFORCING
VERTICAL BARS
PEDESTAL SCHEDULE
16" x 20"
TIES
(4) #6 #4 TIES @ 12" O.C.
AB-1
MARK DIAMETER
"D"
3/4"
EMBEDMENT
"E"
PROJECTION
"P"
BOLT
GRADE
1'-4" 3" 36
1.1ASCALE: 1/4" = 1'-0"
BLEACHER ENCLOSURE- FOUNDATION PLAN
1.1ASCALE: 1/4" = 1'-0"
BLEACHER ENCLOSURE- PLAN
1.2ASCALE: 3/4" = 1'-0"
TYP. FOOTING W/ PEDISTAL 12
1.1ASCALE: 1 1/2" = 1'-0"
SLAB DETAIL10
1.1ASCALE: 1/2" = 1'-0"
FOUNDATION DETAIL 13
1.1ASCALE: 3" = 1'-0"
ANCHOR BOLT DETAIL11
1.1ASCALE: 3/4" = 1'-0"
PEDISTAL DETAIL
STRUCTURAL NOTES
1. FOUNDATIONS HAVE BEEN DESIGNED FOR AN ALLOWABLE
BEARING PRESSURE OF…
This is the start of the file's text. The full file is on GovTribe.