This is a construction document set for Sterling Elementary School fencing upgrades prepared by MHTN Architects for the Tooele County School District located at 135 South 7th Street, Tooele, Utah 84074. The project consists of two bid options: a Base Bid for removal of existing metal crash gates and installation of new 6-foot tall chain-link fence and gates with associated concrete mow strips, sidewalk work, and landscape and irrigation repairs; and Bid Alternate 1 for removal and replacement of precast concrete caps, installation of new ornamental fence with exit hardware, and new precast concrete caps. An optional pre-bid walkthrough is scheduled for September 15, 2026, with contact to Michael Garcia (mgarcia@tooeleschools.org) required to schedule attendance. Questions from bidders will be accepted through the U3P-Bonfire bid platform until 3:00 p.m. on September 22, 2026, and sealed bids are due September 29, 2026 by 3:00 p.m. through the same platform. The construction documents were issued May 22, 2026, and include detailed site plans, specifications, and technical details referencing applicable codes including the 2018 International Building Code, 2017 National Electrical Code, and 2018 International Fire Code, as well as ADA Standards for Accessible Design.
The documents establish specific contractor responsibilities including coordination of all demolition and construction work with the school owner to avoid interference with facility operations, protection of existing utilities and plant material, maintenance of the existing irrigation system during construction, proper disposal of demolished materials, and repair of any damage to existing areas. The contractor is responsible for field verification of the existing sprinkler irrigation system and must maintain lawn and shrub irrigation on separate circuits. Expansion joints are required at 30-foot to 50-foot intervals depending on application, and all site lighting fixtures must be staked and approved by the architect prior to installation. The concrete mow strips are specified with #4 epoxy-coated rebar, and ornamental fence sections require core drilling through existing concrete caps or removal and replacement as required for new fence post installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-Advertisement for Bids - Sterling Elementary Fencing Upgrade.docx | DOCX document | |
| 6-Sterling Pre-Bid and Question.docx | DOCX document | |
| 5-Sterling Sign In.pdf | ||
| 3-Sterling Elementary Fencing Upgrades - PM - ADA - 05222026.pdf | ||
| 2-004113 - BID FORM - Sterling.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT DATA
CIVIL RIGHTS
ADA Standards for Accessible Design, 2010
APPLICABLE CODES
International Building Code, including Appendix J (IBC), 2018 ed.
National Electrical Code (NEC), 2017 ed.
International Fire Code (IFC), 2018 ed.
A. OCCUPANCY AND GROUP - A5
CHANGE IN USE - NO
ABBREVIATIONS
AC AIR CONDITIONING
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BO BOTTOM OF
BOT BOTTOM
BRB BUCKLING RESTRAINED BRACE
BRG BEARING
CB CATCH BASIN
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEANOUT, CLEAR OPENING
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONF CONFERENCE
CONST CONSTRUCT, CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CTR CENTER
DB DECK BEARING ELEVATION
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DOOR
DTL DETAIL
DWG DRAWING
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRICAL WATER COOLER
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIN FLR FINISH FLOOR
FLR FLOOR
FT FOOT, FEET
GA GAUGE, GAGE
GI GALVANIZED IRON
GLULAM GLUED-LAMINATED TIMBER
GYP BD GYPSUM BOARD
HVAC HEATING, VENTILATION, AIR CONDITIONING
ID INSIDE DIAMETER
INT INTERIOR
ISO ISOMETRIC
JAN JANITOR
JT JOINT
KD KNOCK DOWN
LAB LABORATORY
LAV LAVATORY
MAINT MAINTENANCE
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFOI OWNER FURNISHED OWNER INSTALLED
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OH OVERHEAD
OH DR OVERHEAD DOOR
OPP OPPOSITE
PERP PERPENDICULAR
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PR PAIR
PREFAB PREFABRICATED
QTY QUANTITY
RD ROOF DRAIN
RE: REFER TO
REINF REINFORCE, REINFORCING
REQD REQUIRED
REF REFRIGERATOR
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
RV ROOF VENT
SF SQUARE FEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
THK THICK, THICKNESS
TO TOP OF
TOB TOP OF BEAM
TOD TOP OF DECK
TOS TOP OF SLAB, TOP OF STRUCTURE
TOW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THROUGH ROOF
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
W WIDE FLANGE
WH WATER HEATER
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
N
GENERAL SYMBOLS
NORTH ARROW
A1011
A101
S 3 1 A X 12 / 33
EL: 100'-0"
VERTICAL ELEVATION
SPOT ELEVATION
DRAWING
REVISION
ROOM NAME
ROOM NUMBER
KEYED NOTES
DOOR NUMBER
SHEET WHERE DRAWN
BUILDING SECTION
WALL SECTION
DETAIL
EXTERIOR ELEVATION
WINDOW TYPE
INTERIOR WALL TYPE
REVISION NUMBER INTERIOR ELEVATION
SEE PLUMBING, MECHANICAL AND ELECTRICAL FOR DISCIPLINE SYMBOLS
GRID REFERENCE MARK
A1 Starts at lower left corner Number Horizontal Letters Vertical
MHTN SHEET NUMBER
Sheet Number Sequencce Sheet Type Discipline
ACT1
ROOM VOLUME / AREA
CEILING TAG
SHEET WHERE DRAWN
SHEET WHERE DRAWN
SHEET WHERE DRAWN
SHEET WHERE DRAWN
A 1 01
A101
SIM
CALLOUT
SHEET WHERE DRAWN
B
A
1 2
CASEWORK TYPE
DEPTH
HEIGHT
WIDTH
LEVEL
ELEVATION
A101
SIM
A101
SIM
A101
SIM
A101
QUALIFIER, IF NEEDED
FIRE RATING, IF NEEDED
CORE THICKNESS
CORE MATERIAL
THICKNESS (MIL), IF OTHER
THAN 30 MIL (20 GA)
STUD SPACING,
IF OTHER THAN 16" OC
E1
EXTERIOR WALL TYPE
ROOF TYPE
FLOOR TYPE
HEIGHT & STC
ST2 SIGNAGE TYPE
ROOM
150 SF
10'-0"
CEILING TYPE TAG
MHTN ARCHITECTS, INC.
280 SOUTH 400 WEST Ste 250
SALT LAKE CITY, UTAH 84101
PHONE: (801) 595-6700
LANDSCAPE
COVER SHEET
G000
INDEX TO DRAWINGS - BID SET
GENERAL
G000 COVER SHEET
LANDSCAPE
AS200 STERLING- OVERALL SITE PLAN
AS201 STERLING- ENLARGED SITE PLAN
AS501 SITE DETAILS
VICINITY MAP
135 S 7TH ST
TOOELE, UT 84074
CONSTRUCTION DOCUMENTS
MAY 22, 2026
TOOELE SCHOOL DISTRICT
STERLING ELEMENTARY FENCING UPGRADES
GENERAL NOTES
1. CONSTRUCT ALL SCORE JOINTS FROM THE ARCHITECTURAL
SITE PLAN.
2. CONTRACTOR SHALL REVIEW ALL EXPANSION JOINT
LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION.
3. INSTALL EXPANSION JOINTS @ 30'-0" O.C. MAX. THROUGHOUT.
4. SCORE JOINTS IN PAVING ARE TO MATCH THE PAVING WIDTH
TYPICAL, UNLESS NOTED OR SHOWN OTHERWISE.
5. COORDINATE ALL SITE LIGHTING FIXTURE LOCATIONS WITH
THE LANDSCAPE DRAWINGS. ALL SUCH LIGHTING SHALL BE
STAKED FOR APPROVAL BY THE ARCHITECT PRIOR TO
CONSTRUCTION.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ANY
ITEMS OR UTILITIES NOT NOTED TO BE REMOVED AND SHALL
BEAR THE COST OF REPAIR TO ORIGINAL CONDITION.
7. CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES NOT
NOTED TO BE REMOVED AND REPAIR TO EXISTING CONDITION
AT NO ADDITIONAL COST TO THE OWNER.
8. ALL CONSTRUCTION OPERATIONS SHALL NOT INTERFERE
WITH OPERATIONS OF OR ACCESS TO FACILITIES UNLESS
AGREED TO BY OWNER. NOR RESTRICT ACCESS ON THE
PUBLIC R.O.W. TEMPORARY ENTRY CLOSURE TO BE
APPROVED IN WRITING BY THE OWNER AND LOCAL
JURISDICTION. COORDINATE ALL DEMOLITION WORK AND
TIMES WITH THE OWNER.
9. THIS CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT ALL
EXISTING PLANT MATERIAL AND LANDSCAPE NOT SHOWN TO
BE REMOVED. INSTALL A TEMPORARY FENCE AROUND THE
DRIP LINE OF ALL TREES WHEN REQUIRED.
10. MAINTAIN AND PROTECT AS MUCH OF THE EXISTING
IRRIGATION SYSTEM AS POSSIBLE AND FEASIBLE AND STILL
PROVIDE FOR FULL COVERAGE OF THE ENTIRE AREA. KEEP
ALL LAWN AREA HEADS ON A SEPARATE CIRCUIT FROM SHRUB
AREA HEADS.
11. THE EXISTING IRRIGATION SYSTEM TO REMAIN IN USE SHALL
BE PATCHED AND REPAIRED AS NECESSARY. MAINTAIN
OPERATION OF THE EXISTING SYSTEM AS REQUIRED TO
PROTECT EXISTING PLANT MATERIAL.
12. ANY QUESTIONS OR CONDITIONS WHICH ARE ENCOUNTERED
THAT ARE NOT COVERED OR ARE IN CONFLICT WITH THE
DOCUMENTS NEED TO BE BROUGHT TO THE ATTENTION OF
THE ARCHITECT FOR RESOLUTION PRIOR TO COMMENCEMENT
OF WORK.
13. ALL DEMOLISHED OR REMOVED MATERIALS SHALL BE
LEGALLY DISPOSED OF BY THE CONTRACTOR.
14. THE CONTRACTOR SHALL PROTECT ADJACENT
CONSTRUCTION AND KEEP FREE FROM DAMAGE, ALL DAMAGE
TO EXISTING AREAS WILL BE REPAIRED BY THE CONTRACTOR
AT THEIR COST.
15. CONTRACTOR IS TO CLEAN ALL AREAS AFFECTED BY
CONSTRUCTION WORK TO THE SATISFACTION OF THE OWNER
AND ARCHITECT.
16. ALL DAMAGED AREAS ARE TO BE REPLACED TO MATCH
EXISTING FINISH AND MATERIAL.
17. IT IS THE RESPONSIBILITY OF THE CONTRACTOR,
SUB-CONTRACTOR OR ANY ASSIGNEES TO ASSURE ALL WORK,
INCLUDING SHOP DRAWINGS, MEET THE INTENT OF ALL
APPLICABLE CODES AS NOTED ON COVER SHEET.
18. DRAWINGS AND SPECIFICATIONS ARE TO BE CONSIDERED A
COMPLETE SET. ALL PARTIES ARE RESPONSIBLE TO COMPLY
WITH BOTH AS ONE SET OF DOCUMENTS, INCASE OF
CONFLICTING INFORMATION THE MOST RESTRICTIVE
CONDITION SHALL PREVAIL- NOTIFY ARCHITECT FOR FINAL
RESOLUTION OF CONFLICTS.
19. DO NOT SCALE THE DRAWINGS.
DEMOLITION NOTES
1. THE CONTRACTOR SHALL COORDINATE ALL DEMOLITION
WORK AND TIMES WITH THE OWNER.
2. THIS CONTRACTOR SHALL BE RESPONSIBLE TO ASCERTAIN
THE LOCATIONS OF ALL UTILITIES AND PROTECT THE SAME.
3. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO
ANY ITEMS OR UTILITIES NOT NOTED TO BE REMOVED AND
SHALL BEAR THE COST OF REPAIR TO ORIGINAL CONDITION.
4. ALL IRRIGATION HEADS REMOVED SHALL BE RETURNED TO
THE OWNER.
5. SAW CUT AND REMOVE CONCRETE PAVING FROM JOINT TO
JOINT.
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
CONSULTANTS, INC.
Address Suite 100 City, State 12345 Telephone (123) 456-7890 Telefax (123) 456-7890 www.consultant.com
NO.
VIEW AND PRINT THIS DRAWING IN COLOR
MAY 22, 2026
CONSTRUCTION DOCUMENTS
ISSUE
2026515
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
TO
O
EL
E
C O
U N
TY
S
C H
O O
L D
IS
TR
IC
T
Original drawing is 30 x 42. Do not scale contents of this drawing.
©2020 MHTN ARCHITECTS, INC.
ST
ER
LI
N
G E
LE
M
EN
TA
R Y
FE
N
C
IN
G U
PG
R
AD
ES
S 7T
H S
T
TO
O
EL
E, U
T
BASE BID
1. REMOVAL OF EXISTING METAL CRASH GATES, INSTALLATION
OF NEW 6' TALL CHAIN-LINK FENCE AND GATES, ALONG WITH
ASSOCIATED CONCRETE MOW STRIPS, CONCRETE SIDEWALK,
CONCRETE SIDEWALK REMOVAL AND REPLACEMENT AND
ASSOCIATED LANDSCAPE AND IRRIGATION REPAIR.
BID ALTERNATE
1. REMOVE AND REPLACE PRECAST CONCRETE CAP, INSTALL
NEW ORNAMENTAL FENCE, NEW ORNAMENTAL GATES WITH
EXIT HARDWARE AND NEW PRECAST CONCRETE CAP.
NORTH5310.79'SOUTH5310.79'EAST5310.79'WEST5310.79'
COMM
N 90°00'00" E6.85'NORTH6.85'SOUTH6.85'
EAST
6.85'
WEST6.85'
2831.61'
X
X
X
6 4
10 8
6 4
10 8
6 4
10 8
6 4
10 8
6 4
10 8
6 4
10 8
6 4
10 8
6 4
10 8
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X
E-01
06-01
06-01
06-01
01-01
01-01
01-01
06-01
D-01
D-01
06-01
06-01
06-01
06-02
E-02
01-01
06-04
06-05
06-03
B1
AS201
C4
AS201
E1
AS201
06-08
06-08
09-01
09-01
06-02 06-02
09-01
06-08
01-02 01-02
SYMBOL CODE DESCRIPTION DETAIL
01 PAVEMENTS, RAMPS, CURBS
01-01 18" CONCRETE MOWSTRIP D2/AS501
01-02 SAW CUT, REMOVE AND
REPLACE CONCRETE PAVING
AS REQUIRED FOR
INSTALLATION OF NEW FENCE
AND GATE
06 RAILINGS, BARRIERS, FENCING
06-01 6' TALL CHAINLINK FENCE E1/AS501
06-02 6' TALL CHAINLINK SWING
GATE WITH EXIT HARDWARE
06-03 3' TALL ORNAMENTAL FENCE D1/AS501
06-04 7' TALL ORNAMENTAL SWING
GATE WITH EXIT HARDWARE
D3/AS501
06-05 4' TALL ORNAMENTAL FENCE D1/AS501
06-08 6' TALL CHAINLINK SWING
GATE
09 LANDSCAPE AND IRRIGATION
09-01 PATCH AND REPAIR EXISTING
IRRIGATION AND LANDSCAPE
AS REQUIRED DUE TO
CONSTRUCTION OPERATIONS
REFERENCE NOTES
D-01 REMOVE EXISTING CRASH
GATE
REFERENCE NOTES
E-01 EXISTING FENCE
E-02 EXISTING PORTABLE
REFERENCE NOTES SCHEDULE
STERLING-
OVERALL SITE
PLAN
AS2000 15' 30' 60'
SCALE: 1" = 30'-0"
E1 STERLING ELEMNTARY
N
DESCRIPTIONDATENO.
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
CONSULTANTS, INC.
Address Suite 100 City, State 12345 Telephone (123) 456-7890 Telefax (123) 456-7890 www.consultant.com
NO.
VIEW AND PRINT THIS DRAWING IN COLOR
MAY 22, 2026
CONSTRUCTION DOCUMENTS
ISSUE
2026515
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
TO
O
EL
E
C O
U N
TY
S
C H
O O
L D
IS
TR
IC
T
Original drawing is 30 x 42. Do not scale contents of this drawing.
©2020 MHTN ARCHITECTS, INC.
ST
ER
LI
N
G E
LE
M
EN
TA
R Y
FE
N
C
IN
G U
PG
R
AD
ES
S 7T
H S
T
TO
O
EL
E, U
T
IRRIGATION REMODEL
NOTES
1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD
VERIFICATION OF THE EXISTING SPRINKLER IRRIGATION
SYSTEM IN TERMS OF FLOW CAPACITY, VALVE WIRING,
VALVE AND HEAD LAYOUT AND CONTROLLER CAPACITY.
2. THIS CONTRACTOR SHALL COORDINATE ALL DEMOLITION
WORK AND TIMES WITH THE OWNER.
3. MAINTAIN AND PROTECT AS MUCH OF THE EXISTING
IRRIGATION SYSTEM AS POSSIBLE AND FEASIBLE AND
STILL PROVIDE FOR FULL COVERAGE OF THE ENTIRE
AREA. KEEP ALL LAWN AREA HEADS ON A SEPARATE
CIRCUIT FROM SHRUB AREA HEADS.
4. THE EXISTING IRRIGATION SYSTEMS NOTED TO REMAIN IN
USE SHALL BE PATCHED AND REPAIRED AS NECESSARY.
MAINTAIN OPERATION OF THE EXISTING SYSTEM AS
REQUIRED TO PROTECT EXISTING PLANT MATERIAL.
CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE OR
DEATH OF EXISTING PLANT MATERIAL.
5. ALL SALVAGED HEADS SHALL BE RE-USED IN THE NEW
SYSTEM, IF COMPATIBLE WITH NEW HEADS, OR
RETURNED TO THE OWNER.
6. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR
PROTECTING THE EXISTING VALVE WIRING AND
RE-ROUTING AS SHOWN AND AS REQUIRED. MINIMIZE THE
USE OF WIRE SPLICES. PROVIDE TEMPORARY WIRING AS
REQUIRED TO KEEP THE EXISTING SYSTEM IN OPERATION.
7. REPAIR DAMAGE TO EXISTING IRRIGATION SYSTEM AND
LAWN RESULTING FROM CONSTRUCTION OPERATIONS.
DEMOLITION NOTES
1. THIS CONTRACTOR SHALL COORDINATE ALL
DEMOLITION WORK AND TIMES WITH THE OWNER.
2. THIS CONTRACTOR SHALL BE RESPONSIBLE TO
ASCERTAIN THE LOCATIONS OF ALL UTILITIES.
3. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR
DAMAGE TO ANY ITEMS OR UTILITIES NOT NOTED TO BE
REMOVED AND SHALL BEAR THE COST OF REPAIR TO
ORIGINAL CONDITION.
4. SAW CUT AND REMOVE CONCRETE PAVING FROM JOINT
TO JOINT.
BID ALTERNATE # 1
X
X
X
X
X
X
X
X
X
6 4
6 4
10 8
6 4
10 8
6 4
10 8
6 4
10 8
6 4
10 8
X
X
X
X
X
X
X
X
X
E-01
06-01
06-01
06-01
01-01
01-01
01-01
06-01
D-01
06-02 06-02
09-01
09-01
09-01
06-08
01-02
01-02
06-10
01-01
SYMBOL CODE DESCRIPTION DETAIL
01 PAVEMENTS, RAMPS, CURBS
01-01 18" CONCRETE MOWSTRIP D2/AS501
01-02 SAW CUT, REMOVE AND
REPLACE CONCRETE PAVING
AS REQUIRED FOR
INSTALLATION OF NEW FENCE
AND GATE
06 RAILINGS, BARRIERS, FENCING
06-01 6' TALL CHAINLINK FENCE E1/AS501
06-02 6' TALL CHAINLINK SWING
GATE WITH EXIT HARDWARE
06-03 3' TALL ORNAMENTAL FENCE D1/AS501
06-04 7' TALL ORNAMENTAL SWING
GATE WITH EXIT HARDWARE
D3/AS501
06-05 4' TALL ORNAMENTAL FENCE D1/AS501
06-06 CORE DRILL NEW FENCE
POSTS THROUGH EXISTING
CONCRETE CAP
06-08 6' TALL CHAINLINK SWING
GATE
06-09 COORDINATE WITH OWNER
LOCATION OF FENCE POST AT
BUILDING. COORDINATE WITH
WINDOWS, ROOF DRAINS,
POWER OUTLETS, HOSE BIBS
ETC...
06-10 COORDINATE FENCE POST
LOCATION WITH EXISTING
BELOW GRADE IRRIGATION
EQUIPMENT
09 LANDSCAPE AND IRRIGATION
09-01 PATCH AND REPAIR EXISTING
IRRIGATION AND LANDSCAPE
AS REQUIRED DUE TO
CONSTRUCTION OPERATIONS
REFERENCE NOTES
D-01 REMOVE EXISTING CRASH
GATE
REFERENCE NOTES
E-01 EXISTING FENCE
E-02 EXISTING PORTABLE
REFERENCE NOTES SCHEDULE
06-04
06-05
06-03
06-06
06-06
X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X
D-01
06-01
06-01
06-01
06-02
E-02
01-01
01-01
06-08
06-08
01-02 21'-6"
09-01
09-01
06-09
01-02
STERLING-
ENLARGED
SITE PLAN
AS2010 5' 10' 20'
SCALE: 1" = 10'-0"
E1 SOUTH GATE
N
DESCRIPTIONDATENO.
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
CONSULTANTS, INC.
Address Suite 100 City, State 12345 Telephone (123) 456-7890 Telefax (123) 456-7890 www.consultant.com
NO.
VIEW AND PRINT THIS DRAWING IN COLOR
MAY 22, 2026
CONSTRUCTION DOCUMENTS
ISSUE
2026515
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
TO
O
EL
E
C O
U N
TY
S
C H
O O
L D
IS
TR
IC
T
Original drawing is 30 x 42. Do not scale contents of this drawing.
©2020 MHTN ARCHITECTS, INC.
ST
ER
LI
N
G E
LE
M
EN
TA
R Y
FE
N
C
IN
G U
PG
R
AD
ES
S 7T
H S
T
TO
O
EL
E, U
T
0 5' 10' 20'
SCALE: 1" = 10'-0"
B1 PLAYGROUND FENCE BID ALTERNATE #1
N
0 5' 10' 20'
SCALE: 1" = 10'-0"
C4 NORTH GATE
N
SITE DETAILS
AS501
DESCRIPTIONDATENO.
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
CONSULTANTS, INC.
Address Suite 100 City, State 12345 Telephone (123) 456-7890 Telefax (123) 456-7890 www.consultant.com
NO.
VIEW AND PRINT THIS DRAWING IN COLOR
MAY 22, 2026
CONSTRUCTION DOCUMENTS
ISSUE
2026515
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
TO
O
EL
E
C O
U N
TY
S
C H
O O
L D
IS
TR
IC
T
Original drawing is 30 x 42. Do not scale contents of this drawing.
©2020 MHTN ARCHITECTS, INC.
ST
ER
LI
N
G E
LE
M
EN
TA
R Y
FE
N
C
IN
G U
PG
R
AD
ES
S 7T
H S
T
TO
O
EL
E, U
T
4"
9"
5"
1 1 /2"
3" 3'-
0"
1'-6"
9"
5"
6'- 0"
TOP RAIL
FABRIC ON BLDG SIDE
CONCRETE MOW STRIP.
CONTINUOUS. CROWN STRIP
SLIGHTLY AT POSTS.
HOLD FINISH GRADE 1-1/2"
BELOW STRIP
COMPACTED NATIVE SOIL
BELOW STRIP
ANCHOR POSTS IN CONCRETE
FENCE W/ CONC. CURB DETAIL
1/2" = 1'-0"
E1
TCSD-2026515-323113-08
9"
1'-6"
NOTE:
INSTALL EXPANSION JOINTS
@ 50'-0" O.C. MAX.
JOINT AT EACH POST,
BUT NO FURTHER THAN
10'-0" MIN DEPTH OF 1/4
SLAB THICKNESS
CONCRETE MOW STRIP
FABRIC
FENCE POST
FENCE W/ 18" CONC. CURB DETAIL
3/4" = 1'-0"
9"
E2
TCSD-2026515-323113-07
ORNAMENTAL METAL FENCE
3/8" = 1'-0"
3 3 4" TYP.
8'-0" O.C. MAX.
EQUAL PER RUN
2"
BRACKET
OPTIONS
PICKET
RAIL
" M
IN
DE
PT
H
9 3 /4"
1"4"
12" CONCRETE
MOW STRIP
FACE OF
BUILDING
NOTE:
SEE SPECIFICATIONS
FOR FENCE MATERIAL
AND ACCESSORIES
6'- 0"
6" MIN.
COVERAGE
ALL SIDES
FENCE POST
EXTENSION
INTO GRADE
E3
TCSD-2026515-323119-03
6'- 0"
9" 2"
4'- 6"
SECTION
FINISH GRADE
FENCE PICKET
FENCE POST
FENCE RAILS
FENCE RAIL
ORNAMENTAL METAL FENCE SECTION
1/2" = 1'-0"
E4
TCSD-2026515-323119-01
1'- 0"
8'-0"
POST
PICKET
RAIL
MOW STRIP
FRAME GATE
WITH 2X2 T.S.
PROVIDE 3 HINGES
& PADLOCK HASP
NOTE:
INSIDE COURT
GATE AND FENCE PLAN
ORNAMENTAL METAL FENCE PLAN
1/2" = 1'-0"
E5
TCSD-2026515-323119-02
ORNAMENTAL FENCE GATE WITH EXIT HARDWARE
3/8" = 1'-0"
4'-0" or 6'-0"
SEE PLAN2'-0" 2'-0"EXIT HARDWARE, SEE
ARCHITECTURAL DOOR
SCHEDULE
LATCH RECEIVER
BRACKET
6'- 0"
O R
7'- 0"
H
IG
H
OR
NA
ME
NT
AL
GA
TE
- S
EE
P
LA
N
FLATTENED EXPANDED
METAL MESH. TACK
WELD TO GATE. METAL
FINISH TO MATCH GATE
FINISH GRADE
ORNAMENTAL FENCE
1"
LOCK KEY CYLINDER IN
GATE FRAME
TCSD-2026515-323119-12
D3
EXISTING BLOCK WALL
WALL DETAIL WITH ORNAMENTAL FENCE
3/4" = 1'-0"
FINISHED GRADE
FENCE POSTS-3"X3" T.S.
3'- 0"
FENCE PICKETS- 3 4"X3
4" @ 6" O.C. MAXIMUM
EQUAL SPACES IN BAY
FENCE POSTS-3"X3" T.S.
FENCE RAILS-2"X2" T.S.
SOLID TOP
3'- 0"
O R
4'- 0"
O R
5'- 0"
SE
E
PL
AN
REMOVE AND REPLACE EXISTING
CONCRETE CAP OR CORE DRILL
THROUGH CAP AS REQUIRED FOR
INSTALLATION OF NEW FENCE POSTS
ELEVATION:
FRONT VIEW
2'- 6"
M
IN
REMOVE AND REPLACE EXISTING CONCRETE
CAP OR CORE DRILL THROUGH CAP AS
REQUIRED FOR INSTALLATION OF NEW FENCE
POSTS
EXISTING BLOCK WALL
D1
TCSD-2026515-323119-11
18"
6" 1-
1/2
NOTE: PROVIDE 1/4"
RADIUS FINISH AT ALL
EDGES - TYPICAL.
COMPACTED FILL OR
UNDISTURBED SOIL
FINISHED GRADE
CONCRETE MOW STRIP W/
LIGHT BROOM FINISH
CONCRETE MOWSTRIP
1 1/2" = 1'-0"
#4 EPOXY COATED REBAR
CONTINUOUS
NOTE: ALL MOWSTRIP TO
BE CONSTRUCTED WITH
#4 EPOXY COATED BAR.
D2
TCSD-2026515-329413-01
CHAINLINK FENCE GATE WITH EXIT HARDWARE
3/8" = 1'-0"
4'-0" or 6'-0"
SEE PLAN2'-0" 2'-0"EXIT HARDWARE, SEE
ARCHITECTURAL DOOR
SCHEDULE
6'- 0"
O R
7'- 0"
H
IG
H
OR
NA
ME
NT
AL
GA
TE
- S
EE
P
LA
N
FLATTENED EXPANDED
METAL MESH. TACK
WELD TO GATE. METAL
FINISH TO MATCH GATE
FINISH GRADE
CHAINLINK FENCE
LATCH RECEIVER
BRACKET
1"
LOCK KEY CYLINDER IN
GATE FRAME
C2
TCSD-2026515-323113-09
| Sheets and Views |
| G002-G002 |
| AS200-AS200 |
| AS201-AS201 |
| AS501-Sterling-AS501 |
File details come from the government source that posted it. Updated .