DATA SHEET

WDS-10033-03

Hydroverse Water Meter Electromagnetic Flow Measurement System for Commercial and Industrial Applications

BENEFITS

� Wide flow range for greater application flexibility

� Superior low-flow accuracy, even for raw water

� Remote register available

(recommended for wet locations)

� No moving parts minimizes wear and prolongs meter life

� Ease of programming with user-friendly mobile application

� AMI/AMR capable

� Minimal head loss ensures consistent accuracy

� 10-year battery life

� Field replaceable batteries

� Optional NFC coupler

� Internal, downloadable data logger

� Internal self-verification continuously monitors meter performance

Sensus Hydroverse™ water meters deliver industry-leading accuracy, flow range and low-flow sensitivity for commercial and industrial potable, reclaimed and raw water applications. Using proven electromagnetic metering technology, the Hydroverse meter is ideally suited to capture revenue from large commercial accounts, enable district/zone metering and measure export or raw water flow. Benefit from the ease of programming, flexible communication, data storage, power supply options, configurable alarms and minimal head loss provided by this smart commercial water meter.

Industry Leading Performance The Hydroverse water meter offers accuracy of ±0.4 percent or optional

±0.2 percent over a wide flow range. The internal verification algorithm runs automatically, maintaining accuracy over the life of the meter.

Hydroverse Manager Software, the intuitive mobile app available for Android™* devices, offers easy programmability to ensure meter configuration for optimal performance.

Solid State Magnetic Technology The Hydroverse meter uses industry-proven electromagnetic technology that provides superior accuracy for a wider range of flow conditions than most metering technologies available today. With no moving parts, the

Hydroverse meter will not suffer accuracy drift due to wear common to other metering technologies. This reduces total cost of ownership through less frequent meter testing and repairs.

Construction The Hydroverse meter consists of a measuring tube and a liner. The measuring tube is made of steel with corrosion-resistant coating. The hard rubber (non-magnetic) liner is resistant to corrosion, aging and abrasion. The Hydroverse meter is IP68 rated to 30 feet.

Electronic Register The Hydroverse electronic register is available as an integral register for dry locations or remote register with placement up to 165 feet (50m) away from the meter. The easy-to-read LCD can be configured to display forward, reverse and total consumption, flow rate and alarms. Register output options include

Sensus communication protocol and configurable pulse output. The register is IP68 rated to a depth of

6 feet for a cumulative time period of 9 months. The optional remote register, mounted above the water-line, is recommended for meter installations that are frequently or continually submerged.

AMI / AMR Compatibility Sensus Hydroverse meters are compatible with common AMI / AMR systems, including the Sensus

FlexNet® communication network.

Conformance to Standards The Hydroverse is NSF Standard 61 compliant.

Flanges are ASME B16.5 Standard and Class CL150.

2” meters and larger comply with AWWA Standard

C715.

Service Measurement of potable, reclaim and raw water

� Storage air temp.: -4° to 140° F (-20° to 60° C) � Operating air temp.: -4° to 140° F (-20° to 60° C) � Operating water temp.: 33° to 122° F (0.5° to 50° C) � Max operating pressure: 232 psi (16 bar) � Minimum water conductivity: 20 μS/cm

Hydroverse Water Meter Electromagnetic Flow Measurement System for Commercial and Industrial Applications

Dimensions and Weights

Meter and Pipe Size

Low Flow Limit (±1.5% accuracy)

Normal Operating Range (±0.4% or optional ±0.2% accuracy)

Max Intermittent Flow

Flange Outer Diameter (D)

Bolt Circle Diameter

(B)

Number of Holes

(N)

Bolt Hole Diameter (Y)

Sensor Length (L)

Register Height (F)

Approximate Weight

1-1/2”

DN40

0.28 0.06

GPM

m3/hr

0.44 - 150

0.10 - 34

GPM

m3/hr

GPM

m3/hr

5.9 in mm

3.9 in mm

5/8 15.7 in mm

7.9 in mm

6.2 in mm lb kg

2”

DN50

0.44 0.10

GPM

m3/hr

0.70 - 220

0.16 - 50

GPM

m3/hr

GPM

m3/hr

6.5 in mm

4.8 in mm

3/4 in mm

7.9 in mm

6.4 in mm lb kg

3”

DN80

1.1 0.25

GPM

m3/hr

1.8 - 510

0.40 - 116

GPM

m3/hr

GPM

m3/hr

7.9 in mm

6.0 in mm

3/4 in mm

7.9 in mm

7.1 in mm lb kg

4”

DN100

1.8 0.4

GPM

m3/hr

2.8 - 920

0.64 - 209

GPM

m3/hr

1,150

GPM

m3/hr

9.3 in mm

7.5 in mm

3/4 in mm

9.8 in mm

8.0 in mm lb kg

6”

DN150

GPM

m3/hr

7 - 2,800

1.6 - 636

GPM

m3/hr

3,500

GPM

m3/hr

11.8 in mm

9.5 in mm

7/8 in mm

11.8 in mm

9.2 in mm lb kg

8”

DN200

1.6

GPM

m3/hr

11 - 3,700

2.5 - 840

GPM

m3/hr

4,625 1,050

GPM

m3/hr

13.5 in mm

11.7 in mm

7/8 in mm

13.8 in mm

10.2 in mm lb kg

10”

DN250

6.4

GPM

m3/hr

45 - 7,045 10 - 1,600

GPM

m3/hr

8,807 2,000

GPM

m3/hr

15.9 in mm

14.3 in mm in mm

17.7 in mm

12.6 in mm lb kg

12”

DN300

GPM

m3/hr

70 - 11,008 16 - 2,500

GPM

m3/hr

13,760 3,125

GPM

m3/hr

19.1 in mm

17.0 in mm in mm

19.7 in mm

13.5 in mm lb kg

14”

DN350

GPM

m3/hr

113 - 17,613 26 - 4,000

GPM

m3/hr

22,017 5,000

GPM

m3/hr

21.1 in mm

18.8 in mm

1 1/8 in mm

21.7 in mm

14.1 in mm lb kg

16”

DN400

GPM

m3/hr

148 - 22,897 34 - 5,200

GPM

m3/hr

28,622 6,500

GPM

m3/hr

23.6 in mm

21.3 in mm

1 1/8 in mm

23.6 in mm

15.7 in mm lb kg

18”

DN450

GPM

m3/hr

178 - 27,741 40 - 6,300

GPM

m3/hr

34,676 7,875

GPM

m3/hr

25.0 in mm

22.8 in mm

1 1/4 in mm

23.6 in mm

16.0 in mm lb kg

20”

DN500

GPM

m3/hr

218 - 33,906 50 - 7,700

GPM

m3/hr

42,382 9,625

GPM

m3/hr

27.6 in mm

25.0 in mm

1 1/4 in mm

23.6 in mm

16.0 in mm lb kg

24”

DN600

GPM

m3/hr

282 - 44,033 64 - 10,000

GPM

m3/hr

55,042 12,500

GPM

m3/hr

32.1 in mm

29.5 in mm

1 3/8 in mm

31.5 in mm

18.0 in mm lb kg

Larger sizes are available. Ask your Sensus representative for details.

3.5” (89)

3.3” (84)

3.7” (93)

7.2” (184)

5.7” (145)

Ø 4.1” (103)

Ø D

F

L

Direction of �ow

B

5.6”Ø 4.1”3.5” (89)

Ø D

3.7” (93)

7.2” (184)

A

L

F

3.3” (84)

(143)(103)

Direction of flow

B

5.7” (145)Ø 4.1”

(103)

3.5” (89)

Ø D

3.7” (93)

7.2” (184)

G

L

F

3.3” (84)

Direction of flow

B

Hydroverse:

1½” - 8”

Hydroverse:

10” - 16”

Hydroverse:

18” - 24”

Hydroverse Water Meter Electromagnetic Flow Measurement System for Commercial and Industrial Applications

637 Davis Drive Morrisville, NC 27560 1-800-638-3748 sensus.com

©2020 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or 1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus.

This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES

IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING

WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND

MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED

HEREIN IS PROHIBITED.

*Android is a trademark of Google LLC.

Hydroverse Water Meter Electromagnetic Flow Measurement System for Commercial and Industrial Applications

Head Loss Curves

0 50 100 150 200 250 300 350 400 450 550500

2”

1.5”

3”

Meter Head Loss (psi) vs. Flow Rate (GPM)

Pr es su er e Lo ss (p si

Flow Rate (GPM)

0 400 800 1200 1600 2000 2400 2800 3200 3600 4000

6”

4”

8”

Meter Head Loss (psi) vs. Flow Rate (GPM)

Pr es su er e Lo ss (p si

Flow Rate (GPM)

Head loss curves are applicable to 1.5" to 8" reduced bore meters.

10" and larger meters are full bore and exhibit negligible head loss across the meter.