3-CurrentWateMeter_CutSheet.pdf
PDF 366 KB Posted
- Attached to
- INSTALLATION OF WATER METER - GRAND CANYON NP
- Solicitation number
- 140P1520Q0072
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PM-723-R1
Mainline Propeller Meters Models 101/102
DESCRIPTION
Model: Sensus 101/102 Propeller Meters are primarily intended for accountability measurement of potable and non-potable cold water with flow in one direction only. Registration accuracy is 100% ± 2% of actual thruput within specified normal flow ranges. Because all appropriate parts are sealed for protection, the meters can be used in water containing particulate solids (such as sand), without causing undue wear.
Performance: The design of the Sensus 101/102 ropeller Meters permits continuous operation up to the maximum rated flow capacity listed for each size, without affecting long term accuracy or causing undue wear. For accurate measurement, a full flow of water through the meter and stated minimum flow rates are required.
Construction: The meter consists of two basic assemblies— the meter tube body and the meter head assembly. Integral straightening vanes in the meter tube body minimize the swirl upstream of the meter so as to direct the flow evenly to the propeller. The 3” through 12” meter tube bodies are internally and externally protected by a superior fusion-bonded epoxy coating for use in potable water systems. The 14” and larger sizes are protected with an epoxy painted finish.
The meter head assembly consists of the propeller, bronze gear box and sealed direct reading register.
Magnetic Drive: Direct magnetic drive eliminates mechanical gearing normally required to operate propeller meter type registers. A ceramic sleeve-type magnet in the propeller assembly drives a follower magnet located in a one piece, all bronze gear box.
This gear box is oil filled and factory sealed to provide lubrication and long life to the register drive shaft.
Propeller: The propeller and nut are made of polypropylene and rotate on a ceramic coated stainless steel spindle.
Registers: Sensus Model 101 Propeller Meters come equipped with a sealed direct reading (DR) register with low flow indicator. The Model 102 is equipped with an electronic rate of flow indicator (E-ROFI) register. The E-ROFI register is an hermetically sealed unit that electronically displays and transmits totalization and flow rate data to various Sensus act-pak instrumentation to monitor, control and record volume and rate of flow. Other register options available are the impulse contactor (IC) and high speed pickup (HSP).
6” Model 101 Propeller Meter
All registers can be positioned in any of four directions for reading ease. Refer to bulletin E-1116 for HSP and bulletin E-1110 for the E-ROFI register.
Installation: Sensus Propeller Meters can be installed in a horizontal, vertical or inclined position. Valves, fittings or other equipment that might create flow turbulence should be positioned at least 5 pipe diameters upstream of the meter and no less than 3 pipe diameters downstream.
Maintenance: The meter head assembly can be removed, repaired and/or replaced without disturbing the meter tube body in line. A spare meter head assembly can be utilized in the event maintenance is required. Cover plates are also available for maintaining service or flushing of lines when the meter head assembly is removed. Factory testing, repair and meter head assembly exchange programs are available.
Standard Sealed Register E-ROFI Register
150 psi (10 bar) Working Pressure Magnetic Drive Flanged Tube Type
PM-723-R1
P.O. Box 487 | 450 North Gallatin Avenue Uniontown, PA 15401 USA T: 1-800-638-3748 F: 1-800-888-2403 www.sensus.com/water h2oinfo@sensus.com
AUTHORIZED SENSUS DISTRIBUTOR
| Low | Flow | Normal | Range | Shipping | |||||||||||||||||
| Meter | GPM | m3/h | GPM | m3/h | A | B | C | D | E | F | G | H | K | Weight | |||||||
| Size | 1 | 2 | in | mm | in | mm | in | mm | in | mm | in | mm | # | in | mm | in | mm | in | mm | Pounds | kg |
| 3” | 80 | GPM | 100-250 | GPM | 16” | 7-1/2” | 3/4” | 6-1/2” | 6” | 4 | 5/8” | 3-3/8” | 5” | 70 | lbs. | ||||||
| DN | 80mm | 18.2 | m3/h | 23-57 | m3/h | 406mm | 190mm | 19mm | 165mm | 152mm | 16mm | 86mm | 127mm | 32 | kg | ||||||
| 4” | 82 | 125-500 | 18” | 9” | 5/8” | 7-1/2” | 7-1/2” | 8 | 5/8” | 3-7/8” | 7-1/2” | 85 | lbs. | ||||||||
| DN | 100mm | 18.6 | 28-114 | 457mm | 229mm | 16mm | 190mm | 190mm | 16mm | 99mm | 190mm | 39 | kg | ||||||||
| 6” | 160 | 220-1200 | 22” | 11” | 11/16” | 9” | 9-1/2” | 8 | 3/4” | 5” | 9” | 115 | lbs. | ||||||||
| DN | 150mm | 36.3 | 50-273 | 559mm | 279mm | 17mm | 229mm | 241mm | 19mm | 127mm | 229mm | 52 | kg | ||||||||
| 8” | 190 | 250-1650 | 24” | 13-1/2” | 11/16” | 9” | 11-3/4” | 8 | 3/4” | 6” | 9” | 150 | lbs. | ||||||||
| DN | 200mm | 43.2 | 57-375 | 610mm | 343mm | 17mm | 229mm | 298mm | 19mm | 152mm | 229mm | 68 | kg | ||||||||
| 10” | 260 | 330-2500 | 26” | 16” | 11/16” | 10” | 14-1/4” | 12 | 7/8” | 7-3/8” | 11” | 200 | lbs. | ||||||||
| DN | 250mm | 59.0 | 75-568 | 660mm | 406mm | 17mm | 254mm | 362mm | 22mm | 187mm | 279mm | 91 | kg | ||||||||
| 12” | 275 | 350-3500 | 28” | 19” | 13/16” | 10” | 17” | 12 | 7/8” | 8-3/8” | 11” | 290 | lbs. | ||||||||
| DN | 300mm | 62.4 | 80-795 | 711mm | 483mm | 21mm | 254mm | 432mm | 22mm | 213mm | 279mm | 132 | kg | ||||||||
| 14” | 350 | 450-4500 | 42” | 21” | 1-3/8” | 12” | 18-3/4” | 12 | 1” | 9-1/4” | 13-1/2” | 450 | lbs. | ||||||||
| DN | 350mm | 79.5 | 102-1022 | 1067mm | 533mm | 35mm | 305mm | 476mm | 25mm | 235mm | 343mm | 204 | kg | ||||||||
| 16” | 450 | 550-5500 | 48” | 23-1/2” | 1-7/16” | 12” | 21-1/4” | 16 | 1” | 10-1/4” | 13-1/2” | 550 | lbs. | ||||||||
| DN | 400mm | 102.2 | 125-1249 | 1219mm | 597mm | 37mm | 305mm | 504mm | 25mm | 260mm | 343mm | 249 | kg | ||||||||
| 18” | 550 | 752-7250 | 54” | 25” | 1-9/16” | 15” | 22-3/4” | 16 | 1-1/8” | 11-5/8” | 13-1/2” | 620 | lbs. | ||||||||
| DN | 450mm | 124.9 | 165-1647 | 1372mm | 635mm | 40mm | 381mm | 578mm | 29mm | 295mm | 343mm | 281 | kg | ||||||||
| 20” | 700 | 850-9000 | 60” | 27-1/2” | 1-11/16” | 15” | 25” | 20 | 1-1/8” | 12-5/8” | 13-1/2” | 820 | lbs. | ||||||||
| DN | 500mm | 159.0 | 193-2044 | 1524mm | 699mm | 43mm | 381mm | 635mm | 29mm | 321mm | 343mm | 372 | kg | ||||||||
| 24” | 1000 | 1300-13000 | 72” | 32” | 1-7/8” | 18” | 29-1/4” | 20 | 1-1/4” | 12-5/8” | 13-1/2” | 1000 | lbs. | ||||||||
| DN | 600mm | 227.1 | 259-2592 | 1829mm | 813mm | 48mm | 457mm | 749mm | 32mm | 321mm | 343mm | 454 | kg | ||||||||
| 30” | 1600 | 2100-18600 | 84” | 38-3/4” | 2-1/8” | 18” | 36” | 28 | 1-1/4” | 12-5/8” | 13-1/2” | 1150 | lbs. | ||||||||
| DN | 750mm | 363.4 | 477-4224 | 2123mm | 984mm | 54mm | 457mm | 914mm | 32mm | 321mm | 343mm | 522 | kg | ||||||||
| 36” | 2400 | 3000-24000 | 96” | 46” | 2-5/8” | 20” | 42-3/4” | 32 | 1-1/2” | 12-5/8” | 13-1/2” | 1350 | lbs. | ||||||||
| DN | 900mm | 545.0 | 681-5450 | 2438mm | 1168mm | 67mm | 508mm | 1086mm | 38mm | 321mm | 343mm | 613 | kg |
1 Low Flow — 95% minimum accuracy 2 Intermittent Flow — 25% over maximum rated capacity
SPECIFICATIONS
| SERVICE | Measurement | of | cold | water | (potable | and | non-potable) | |||
| up | to | 100°F | (38°C) | with | flow | in | one | direction | only. | |
| OPERATING | Continuous | Flows: | Refer | to | the | chart | above | |||
| RANGE | Intermittent | Flows: | 25% | over | the | maximum | rated | |||
| capacity | of | any | given | size. | ||||||
| ACCURACY | 100% | ± | 2% | of | actual | thruput | ||||
| LOW | FLOW | Refer | to | the | chart | above | ||||
| MAXIMUM | 150 | psi | (10 | bar) |
OPERATION
PRESSURE
| FLANGE | 3” | Size: | Round, | AWWA | 150 | Class | |||||
| 4”-12” | Sizes: | Round, | AWWA | Class | D | ||||||
| 14”-36” | Sizes: | Round, | AWWA | 150 | Class | ||||||
| REGISTER | Hermetically | Sealed | Direct | Reading | Register | ||||||
| with | Low | Flow | Indicator | ||||||||
| METER | Standard: | Six | digit, | straight | reading | type | with | Low | Flow | ||
| REGISTRATION | Indicator. | Full | 3” | dial | face | with | 100 | division | increments | ||
| and | a | center | sweep | hand. | |||||||
| E-ROFI: | Twin | six | digit, | LCD | totalizer | and | rate | of | flow | display. | |
| Powered | by | a | “C” | size | lithium | battery | factory | sealed | in | an | |
| hermetically | sealed | register. | Register | replacement | is | ||||||
| recommended | every | five | (5) | years. |
| MATERIALS— | 3” | and | 4” | Size: | Ductile | Iron |
| METER | TUBE | 6”-36” | Sizes: | Fabricated | Steel |
BODY
STRAIGHTENING Fabricated Steel
VANES
| COATINGS | 3”-12” | Sizes: | Fusion-Bonded | Epoxy |
| 14”-36” | Sizes: | Epoxy | Paint | |
| METER | HEAD | Ductile | Iron | |
| PROPELLER | AND | Polypropylene |
NUT
PROPELLER Ceramic Coated Stainless Steel
SPINDLE
| GEAR | HOUSING | One | Piece | Cast | Bronze |
| TRIM | Stainless | Steel | |||
| MAGNETS | Ceramic |
K
4" 108mm
Model 101 Model 102
H
E –Bolt Circle F –No. of Bolts G–Size of Bolts{
31⁄8" 89mm
B
C
D
A
File details come from the government source that posted it. Updated .