4-MultiModal IT Data Bus Bay 30MAR26.pdf

PDF 1 MB Posted

Attached to
Installation of Structured Voice and Data Cabling for the Multimodal Transit Facility
Solicitation number
260080
Issued by
Sedgwick County, Kansas

About this file

This is an architectural drawing for the Wichita Multimodal Transit Facility (The Hub) showing video camera locations and structured cabling infrastructure on the ground floor. The City of Wichita, Kansas, through its Information Technology Department, is seeking bids for the installation of structured voice and data cabling for this transit facility. The drawing, prepared by consultants at 222 South Riverside Plaza, Suite 610, Chicago, Illinois, and dated September 14, 2023 (revised October 6, 2023), specifies multiple camera types including dual view pendant mount cameras (DF-P-D), fixed view dome style pendant mounted cameras (F-D-P), fixed view dome style wall mounted cameras (F-WM), fixed 180-degree view dome style wall mount cameras (F-D-180), and fixed view dome style cameras (F-D). The project requires coordination of electrical sources and conduit routes for Category 6 cabling and fiber optic lines, with a minimum of 3/4-inch EMT conduit specified throughout.

The installation scope includes multiple computer data outlets positioned at ground level with edge-to-wall placement, overhead conduit routing, and a ground connection for kiosk equipment. The contractor must provide shop drawings indicating routing and locations for 120-volt power requirements and coordinate with fiber and hardened switch needs as referenced in interconnection drawing Y-601. The bid set was issued on April 23, 2024, with the facility featuring designated areas for generators, main electrical infrastructure, storage, and bike storage. The structured cabling and video surveillance infrastructure represent essential components of the multimodal transit facility's information technology systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C-1-1

F-WM

C-1-2

F-WM

C-1-3

DF-P-D

C-1-4

DF-P-D

C-1-5

DF-P-D

C-1-6

DF-P-D

C-1-7 F-D-180

C-1-8

DF-P-D

C-1-9

DF-P-D

C-1-10

DF-P-D

C-1-11

DF-P-D

C-1-12

DF-P-D

C-1-13

DF-P-D

C-1-14

DF-P-D

C-1-15

DF-P-D

C-1-16 F-D

C-1-17 F-D

2.6

A B C D EE.1 E.6 F

2.6

A B C D EE.1 E.6 F

Y1

Y2

Y3

Y4

Y7

C-1-18 F-D-P

C-1-19 F-D

C-1-20 F-D

Y3

A B C D EX1 X3

Y2

Y1

Y5

Y6

Y7

X2

Y4

GENERATOR

AREA

MAIN ELEC

STORAGE

BIKE STORAGE

IF THIS DRAWING IS LESS THAN 30" X 42" IT IS A REDUCED SIZE DRAWING

C O

N S

U L T

A N

T S

R

E V

IS

IO

N S

PROJ NO:

SCALE:

DATE:

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SHEET TITLE:

SHEET NO.

SHEET OF

W

IC

H

IT

A M

U L T

I- M

O D

A L

T R

A N

S

IT

F A

C

IL

IT

Y

09/14/2023

AS NOTED

S

O U

T H

R

IV

E R

S

ID

E P

L A

Z A

S

U

IT

E

C H

IC

A

G O

IL

P H

O N

E -6

-9

F A

X -6

-9

/6

/2

:4 :5

P

M

VIDEO CAMERA

LOCATIONS GROUND

FLOOR

Y-201

Project Number

TGL

TGL

MNB

GENERAL NOTES:

1. DF-P-D TYPE CAMERAS ARE DUAL

VIEW PENDANT MOUNT. VIEW OF

BUS LANES AND WAITING AREA

2. F-D-P TYPE CAMERAS ARE FIXED

VIEW DOME STYLE PENDANT

MOUNTED.

3. F-WM TYPE CAMERAS ARE FIXED

VIEW DOME STYLE WALL

MOUNTED.

4. F-D-180 TYPE CAMERAS ARE FIXED

180 DEGREE VIEW DOME STYLE

WALL MOUNT.

5. F-D TYPE CAMERAS ARE FIXED

VIEW DOME STYLE

6. SEE Y-601 INTERCONNECTION FOR

FIBER AND HARDEN SWITCH

NEEDS. COORDINATE ELECTRICAL

SOURCE AND CONDUIT ROUTES

FOR CAT 6 AND FIBER

7. MINIMUM OF 3/4" EMT CONDUIT

SHALL BE USED. CONTRACTOR

SHALL PROVIDE SHOP DRAWINGS

INDICATING ROUTING AND

LOCATIONS OF 120V NEEDS.

1/16" = 1'-0"

Ground Level-cameras

M A

R K

D A

T E

D E

S C

R

IP

T

IO

N

04/23/2024

/2

3/

BI

D S

ET

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Group Computer data outlet, place edge against wall

SKeene Line

SKeene Architect

SKeene Cloud+ 12 Overhead 3 Ground for Kiosk

SKeene Rectangle

SKeene Architect

SKeene Cloud+ Location TBD

File details come from the government source that posted it. Updated .