4-Appendix B Drawings 25027 - Harrisburg Station 1-2 - FULLSET - IFPP - 2026-09-11.pdf
PDF 13 MB Posted
- Attached to
- Fire Station Upgrades
- Solicitation number
- IFB 2026-13 City of Harrisburg, Dauphin County
- Issued by
- Dauphin County, Harveys Lake Borough, Pennsylvania
About this file
This document comprises architectural drawings and specifications for the interior renovation of two Harrisburg fire stations operated by the City of Harrisburg Bureau of Fire. The project encompasses the demolition and reconstruction of bunk rooms, restrooms, showers, and offices at Fire Station #1 (1820 North 6th Street) and Fire Station #2 (140 North 16th Street) in Harrisburg, Pennsylvania. The scope of work includes installation of partitions, doors, interior glazed openings, architectural built-in casework, painting, plumbing fixtures, domestic water and sanitary waste distribution systems, HVAC redistribution, electrical service redistribution, and interior lighting. The project will proceed with partial owner occupancy, with the City of Harrisburg maintaining operations in non-construction areas throughout the renovation period. All bidding requirements and technical specifications are contained within the PennBid solicitation documents and project profile, with a questions and answers guide available to clarify bidder inquiries prior to submission.
Prime and subcontractors interested in bidding on this fire station upgrade project are required to log into the PennBid project profile to indicate their intent to bid. The solicitation documents emphasize that bids containing omissions based on industry assumptions will be deemed non-responsive, and all project requirements are explicitly detailed in the bid solicitation materials. Interested parties are directed to review all supporting documentation and project details before submitting inquiries or attending any site visit. PennBid serves as the sole authoritative source for accurate bid information and requirements for this project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESIGN PROFESSIONAL IN-CHARGE
DENNIS F. SOWERS, AIA
PROJECT TEAM
CITY OF HARRISBURG - STATIONS 1 & 2
HARRISBURG, PA
CITY OF HARRISBURG
10 NORTH SECOND STREET
HARRISBURG, PA 17101
STATION 2 LOCATION MAP
ARCHITECT
PROJECT SITE
NOT TO SCALE
OWNER:
I HEREBY CERTIFY THAT THESE DOCUMENTS WERE PREPARED UNDER
MY SUPERVISION AND THAT I AM A DULY REGISTERED ARCHITECT
UNDER THE LAWS OF THE COMMONWEALTH OF PENNSYLVANIA
LICENSE NO. RA-007999-X
EXPIRATION DATE: JUNE 30, 2027
SIGNATURE DATE
THE FOLLOWING ITEMS WILL CONSIST OF DEFERED SUBMITTALS
(DELEGATED DESIGN):
* NONE
MEP ENGINEER
3 JENNIFER COURT, SUITE 'E'
CARLISLE, PA 17015
(717) 249-4569
RENOVATIONS TO:
STATION 1 LOCATION MAP
PROJECT SITE
NOT TO SCALE
COPYRIGHT © 2025
BY SGS ARCHITECTS ENGINEERS,
INC. THIS DRAWING AND
INFORMATION IS AN INSTRUMENT
OF SERVICE AND SHALL NOT BE
COPIED OR USED IN ANY WAY
WITHOUT WRITTEN
AUTHORIZATION OF SGS. THIS
DRAWING NOT FOR GENERAL USE
AND ALL RIGHTS ARE RESERVED.
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS ON THE DRAWING
AND REPORT ANY ERROR TO
THE ARCHITECT BEFORE
STARTING WORK.
SHEET:
JOB NO.
DATE
CHECK
DRAWN
REVISIONS DATE
S C
A
LE
: 1 /8
1'
0"
0' 2'
8'
S C
A
LE
: 1 /4
1'
0"
0' 1'
2'
8'
S C
A
LE
: 3 /8
1'
0"
0' 1'
2'
6'
S C
A
LE
: 3 /4
1'
0"
0' 1'
2' 3'
S C
A
LE
: 1
/2
1'
0"
0" 6"
3"
S C
A
LE
: 3
1'
0"
0" 3"
6"
1"
2"
S C
A
LE
: 1
1'
0"
0" 6"
3"
R
EN
O V
A
TI
O N
S T
O
J
EN
N
IF
ER
C O
U R
T, S
U
IT
E 'E
C
A R
LI
S
LE
, P
A
(7
9-
C
IT
Y O
F H
A R
R S
IB
U
R G
S
TA
TI
O N
S
RAM
SEPTEMBER 11, 2026
25027
0-C-0.00
C O
V
ER
S H
EE
T
H A
R R
IS
B
U R
G , P
A
DFS
DRAWING LIST
SHEET
NUMBER SHEET NAME
ISSUED FOR PRICING
AND PERMIT -- -- --
0-C-0.00 COVER SHEET 09/11/2026
0-A-0.01 ARCHITECTURAL SYMBOLS, ETC 09/11/2026
0-A-0.02 TYPICAL ADA DETAILS 09/11/2026
0-A-0.03 TYPICAL ASSEMBLIES 09/11/2026
0-A-5.01 TYPICAL DETAILS 09/11/2026
0-A-5.02 TYPICAL DETAILS 09/11/2026
0-M-0.01 MECHANICAL INFORMATION SHEET 09/11/2026
0-M-0.02 MECHANICAL GENERAL NOTES, SCHEDULES, & DETAILS 09/11/2026
0-P-0.01 PLUMBING INFORMATION SHEET 09/11/2026
0-P-0.02 PLUMBING DETAILS 09/11/2026
0-P-0.03 PLUMBING FIXTURE SCHEDULE 09/11/2026
0-E-0.01 ELECTRICAL INFORMATION SHEET 09/11/2026
0-E-4.01 ELECTRICAL DETAILS 09/11/2026
0-E-5.01 ELECTRICAL SCHEDULES 09/11/2026
1-D-1.01 STATION 1 - FIRST FLOOR DEMOLITION PLAN 09/11/2026
1-A-0.01 STATION 1 - CODE ANALYSIS 09/11/2026
1-A-0.02 STATION 1 - CODE ANALYSIS & LIFE SAFETY PLAN 09/11/2026
1-A-1.00 STATION 1 - OVERALL SITE 09/11/2026
1-A-1.01 STATION 1 - OVERALL FIRST FLOOR PLAN 09/11/2026
1-A-1.02 STATION 1 - PARTIAL ENLARGED FLOOR PLAN 09/11/2026
1-A-1.03 STATION 1 - PARTIAL ENLARGED FLOOR PLAN 09/11/2026
1-A-6.01 STATION 1 - INTERIOR ELEVATIONS 09/11/2026
1-A-6.02 STATION 1 - INTERIOR ELEVATIONS 09/11/2026
1-A-7.01 STATION 1 - DOOR SCHEDULE & DETAILS 09/11/2026
1-A-7.02 STATION 1 - ROOM FINISH SCHEDULE & DETAILS 09/11/2026
1-A-8.01 STATION 1 - REFLECTED CEILING PLANS & DETAILS 09/11/2026
1-MD-1.01 STATION 1 - ENLARGED PLANS - DEMOLITION - MECHANICAL 09/11/2026
1-M-1.01 STATION 1 - OVERALL FIRST FLOOR PLAN - MECHANICAL DUCT 09/11/2026
1-M-1.02 STATION 1 - ENLARGED PLANS - MECHANICAL DUCT 09/11/2026
1-PD-1.01 STATION 1 - FIRST FLOOR - DEMOLITION - PLUMBING 09/11/2026
1-P-1.01 STATION 1 - FIRST FLOOR PLAN - DOMESTIC WATER 09/11/2026
1-P-2.01 STATION 1 - FIRST FLOOR PLAN - SANITARY 09/11/2026
1-P-3.01 STATION 1 - ENLARGED PLANS - PLUMBING 09/11/2026
1-ED-1.01 STATION 1 - OVERALL FIRST FLOOR PLAN - DEMOLITION - LIGHTING 09/11/2026
1-ED-2.01 STATION 1 - OVERALL FIRST FLOOR PLAN - DEMOLITION - POWER 09/11/2026
1-E-1.01 STATION 1 - OVERALL FIRST FLOOR PLAN - LIGHTING 09/11/2026
1-E-2.01 STATION 1 - OVERALL FIRST FLOOR PLAN - POWER 09/11/2026
1-E-2.02 STATION 1 - PARTIAL ENLARGED FLOOR PLANS - POWER 09/11/2026
2-D-1.01 STATION 2 - FIRST FLOOR DEMOLITION PLAN 09/11/2026
2-A-0.01 STATION 2 - CODE ANALYSIS 09/11/2026
2-A-0.02 STATION 2 - CODE ANALYSIS & LIFE SAFETY PLAN 09/11/2026
2-A-1.00 STATION 2 - OVERALL SITE PLAN 09/11/2026
2-A-1.01 STATION 2 - OVERALL FIRST FLOOR PLAN 09/11/2026
2-A-1.02 STATION 2 - PARTIAL ENLARGED FLOOR PLAN 09/11/2026
2-A-1.03 STATION 2 - PARTIAL ENLARGED FLOOR PLAN 09/11/2026
2-A-6.01 STATION 2 - INTERIOR ELEVATIONS 09/11/2026
2-A-6.02 STATION 2 - INTERIOR ELEVATIONS 09/11/2026
2-A-7.01 STATION 2 - DOOR SCHEDULE & DETAILS 09/11/2026
2-A-7.02 STATION 2 - ROOM FINISH SCHEDULE & DETAILS 09/11/2026
2-A-8.01 STATION 2 - REFLECTED CEILING PLANS & DETAILS 09/11/2026
2-MD-1.01 STATION 2 - ENLARGED PLANS - DEMOLITION - MECHANICAL 09/11/2026
2-M-1.01 STATION 2 - OVERALL FIRST FLOOR PLAN - MECHANICAL DUCT 09/11/2026
2-M-1.02 STATION 2 - ENLARGED PLANS - MECHANICAL DUCT 09/11/2026
2-PD-1.01 STATION 2 - FIRST FLOOR - DEMOLITION - PLUMBING 09/11/2026
2-P-1.01 STATION 2 - FIRST FLOOR PLAN - DOMESTIC WATER 09/11/2026
2-P-2.01 STATION 2 - FIRST FLOOR PLAN - SANITARY 09/11/2026
2-P-3.01 STATION 2 - ENLARGED PLANS - PLUMBING 09/11/2026
2-ED-1.01 STATION 2 - OVERALL FIRST FLOOR PLAN - DEMOLITION - LIGHTING 09/11/2026
2-ED-2.01 STATION 2 - OVERALL FIRST FLOOR PLAN - DEMOLITION - POWER 09/11/2026
2-E-1.01 STATION 2 - OVERALL FIRST FLOOR PLAN - LIGHTING 09/11/2026
2-E-2.01 STATION 2 - OVERALL FIRST FLOOR PLAN - POWER 09/11/2026
2-E-2.02 STATION 2 - PARTIAL ENLARGED FLOOR PLANS - POWER 09/11/2026
ISSUED FOR PRICING
AND PERMIT
09/11/2026
A101
SIM
A.F.F.
1i
1'-0"
A101
A101
SIM
1 View Name 1/8" = 1'-0"
1i
ARCHITECTURAL SYMBOL REFERENCE LEGEND
GRAPHIC REPRESENTATIONS SHOWN BELOW ARE FOR GENERAL INFORMATION ONLY
NOT ALL REPRESENTATIONS MAY APPLY TO THIS PROJECT
SHEET IDENTIFIER
SECTION IDENTIFIER
VIEW DIRECTION ARROW
LINE OF CUT
BUILDING / WALL SECTION CALL-OUT
ENLARGED PLAN / DETAIL CALL-OUT
SHEET IDENTIFIER
DETAIL IDENTIFIER
AREA OF DETAIL /
ENLARGED PLAN
EXTERIOR ELEVATION CALL OUT
SHEET IDENTIFIER
INTERIOR ELEVATION CALL OUT
SHEET IDENTIFIER
ELEVATION IDENTIFIER
VIEW DIRECTION IDENTIFIER
ELEVATION IDENTIFIER
VIEW DIRECTION IDENTIFIER
A101 1
ROOM OR SPACE IDENTIFIER
ROOM OR SPACE NAME
ROOM OR SPACE NUMBER
AREA OF ROOM OR
SPACE IF INDICATED
STRUCTURAL GRID
GRID LINE IDENTIFIER
STRUCTURAL GRID IDENTIFIER
REVISION IDENTIFIER
DRAWING REVISION
NUMBER IDENTIFIER
DRAWING ITEM NAME
DRAWING ITEM SCALE
DRAWING ITEM NUMBER
VIEW TITLE
DOOR NUMBER
DOOR TAG
WINDOW TYPE
DESIGNATION WINDOW TAG
PARTITION TYPE CALL
OUT
PARTITION TYPE
IDENTIFIER
CEILING TYPE IDENTIFIER
CEILING TYPE IDENTIFIER
CEILING HEIGHT
IDENTIFIER
ACCESSORY IDENTIFIER
ELEVATION HEIGHT CALL OUT
TRUSS BEARING
0'-0" AFF
ELEVATION DESCRIPTION
ELEVATION DISTANCE
ABOVE SLAB
TOILET ACCESSORY TAG
? KEYNOTE TAG
KEYNOTE IDENTIFIER
7.1
ROOF / FLOOR ASSEMBLY TAG
RC-X
ROOF / CEILING
ASSEMBLY IDENTIFIER
Room name
150 SF
1i
A
ABBREVIATIONS
ABBREVIATIONS SHOWN BELOW ARE FOR
GENERAL INFORMATION ONLY - NOT ALL
REPRESENTATIONS MAY APPLY TO THIS PROJECT
A AB ANCHOR BOLT
ABV ABOVE
ACT / AT ACOUSTICAL CEILING TILE
ACM ALUMINUM COMPOSITE METAL
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AGG AGGREGATE
ALUM ALUMINUM
ANC ANCHOR
ANOD ANODIZED
APPROX APPROXIMATE
AP ACCESS PANEL
ARCH ARCHITECTURAL
B BD BOARD
BEL BELOW
BET BETWEEN
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BO BOTTOM OF
BRK BRICK
BSMT BASEMENT
C CAB CABINET
CERT CERTIFIED
CD COMPOSITION DECKING
CFMF COLD FORMED METAL FRAMING
CHNL CHANNEL
CJ CONTROL JOINT
CL CLOSET
CLG /
CLNG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNT COUNTER
COMP COMPOSITE
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
COR CORRUGATED
CPT CARPET
CRS COURSE(S)
CT CERAMIC TILE
CW CURTAIN WALL
D DIA DIAMETER
DIM DIMENSION
DN DOWN
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DWG(S) DRAWING(S)
E EA EACH
EIFS EXTERIOR INSULATING FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EP ELECTRICAL PANEL
EPS EXTERIOR PAINT SYSTEM
EQ EQUAL
ES EXPOSED STRUCTURE
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
F FA FIRE ALARM
FB FIBER BOARD
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FN FINISH(ED)
FLG FIRE-RATED CERAMIC GLAZING
FLR FLOOR(ING)
FND FOUNDATION
FP FILLER PANEL
FO FACE OF
FRP FIBERGLASS REINFORCED PANEL
FTG FOOTING
FUR FURRED(ING)
G GA GAUGE
GALV GALVANIZED
GB GYPSUM BOARD
GF GROUND FACE
GL GLAZED, GLAZING
GLS GLASS
GHM GALVANIZED HOLLOW METAL
GIHM GALVANIZED INSULATED HOLLOW METAL
H HC HANDICAPPED
HCWD HOLLOW CORE WOOD
HDR HEADER
HM HOLLOW METAL
HR HOUR
HOR(IZ) HORIZONTAL
HT HEIGHT
HRDW HARDWOOD
HVAC HEATING VENTILATION AIR CONDITIONING
HWH HOT WATER HEATER
I ICF INSULATED CONCRETE FORM
INFO INFORMATION
INS(UL) INSULATION
INT INTERIOR
IPS INTERIOR PAINT SYSTEM
ISP INSULATED SPANDREL PANEL
J JT JOINT
K KIT KITCHEN
L LAM LAMINATE
LF LINEAR FEET
LG LONG
LIN LINOLEUM
LLV LONG LEG VERTICAL
LTL LINTEL
LOUV LOUVER
M MANUF MANUFACTURER
MAS MASONRY
MAS DIM MASONRY DIMENSION
MAX MAXIMUM
MCJ MASONRY CONTROL JOINT
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEMB MEMBRANE
MFG MANUFACTURER
MIC MICROPHONE
MICRO MICROWAVE
MIN MINIMUM
MNB MEMBRANE
MO MASONRY OPENING
MR MOISTURE RESISTANT
MRGB MOISTURE RESISTANT GYPSUM BOARD
MTL METAL
MULL MULLION
N N NORTH
NA NOT APPLICABLE
NAT NATURAL
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O OC ON CENTER
OH OPPOSITE HAND
OPP OPPOSITE
OSB ORIENTED STAND BOARD
P P PAINT
PBD PARTICLE BOARD
PERF PERFORATED
PF PREFINISHED
PL / PLAM PLASTIC LAMINATE
PNL PANEL
PNLG PANELING
PCT PORCELAIN CERAMIC TILE
PRF POURED-IN-PLACE RUBBER FLOORING
PT PORCELAIN TILE
PTN PARTITION
PLY / PWD PLYWOOD
PLST PLASTER
R R RISERS
RA RETURN AIR
RAD RADIUS
RC RESILIENT COVE BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIGERATOR
REQ'D REQUIRED
RES RESILIENT TILE FLOORING
REV REVISION
RF RESILIENT FLOORING
RM ROOM
RO ROUGH OPENING
RWC RIGID WALL COVERING
S SA SUPPLY AIR
SBO SUPPLIED BY OTHER
SCWD SOLID CORE WOOD
SD SOAP DISPENSER
SE SITE ELEVATION
SIM SIMILAR
SIP STRUCTURAL INSULATED PANEL
SJ SCORE JOINT
SL SLOPE
SLD SEALED
SLR SEALER
SLT SLATE
SOG SLAB ON GRADE
SOD SECTIONAL OVERHEAD DOOR
SS STAINLESS STEEL
ST STAIN
STL STEEL
STV THIN CUT NATURAL STONE VENEER
STRUCT STRUCTURAL
SUSP SUSPENDED
T T TREADS
T&G TONGUE AND GROOVE
TBB TILE BACKER BOARD
TCPT CARPET TILE
TF TRANSPARENT FINISH
TG TEMPERED GLASS
TIG TEMPERED INSULATED GLASS
TO TOP OF
THK THICKNESS
TLT TOILET
TYP TYPICAL
U UNO UNLESS NOTED OTHERWISE
V VAR VARIES
VB VAPOR BARRIER
VC VINYL COVE BASE
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VTR VENT THRU ROOF
W W/ WITH
W/O WITHOUT
WD WOOD
WDWK WOODWORK
WF WIDE FLANGE
WIN WINDOW
WOM WALK OFF MAT
WSP WOOD SHEATHING PANEL
WWF WELDED WIRE FABRIC
GENERAL NOTES:
1. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS NOT ALREADY ACQUIRED BY THE OWNER PRIOR TO THE START OF
CONSTRUCTION UNLESS OTHER ARRANGEMENTS HAVE BEEN MADE AND EXECUTED WITH THE OWNER.
2. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS, REGULATIONS, CODES, AND ORDINANCES. IF A PORTION OF THE WORK IS IN CONFLICT WITH APPLICABLE CODE REQUIREMENTS AND SPECIFICATIONS, THE CONTRACTOR SHALL NOTIFY THE OWNER AND PROFESSIONAL AS SOON AS
POSSIBLE SO THAT A TIMELY RESOLUTION CAN BE INCORPORATED INTO THE WORK.
3. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND CONTRACT REQUIREMENTS ON THE JOB SITE. IF EXISTING FIELD CONDITIONS DO NOT PERMIT THE INSTALLATION OF THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE OWNER AND PROFESSIONAL AS SOON AS POSSIBLE SO THAT A
TIMELY RESOLUTION CAN BE INCORPORATED INTO THE WORK
4. THE GENERAL CONTRACTOR SHALL COORDINATE LOCATIONS AND SIZES OF ALL INTERIOR AND EXTERIOR OPENINGS / PENETRATIONS, ETC. WITH ALL OTHER TRADES AND PRIME CONTRACTORS. THE GENERAL CONTRACTOR SHALL COORDINATE ALL SLEEVE WORK. EACH PRIME CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING SLEEVES FOR THEIR PHASE OF THE WORK. THE GENERAL CONTRACTOR SHALL VERIFY THAT ALL SLEEVES HAVE BEEN PLACED PRIOR TO CLOSING UP THE WORK AND / OR PLACING CONCRETE. ALL CONTRACTORS SHALL COMPLY WITH THE GENERAL CONDITIONS OF THE CONTRACT.
5. UNLESS OTHERWISE NOTED OR INDICATED ON THE DRAWINGS OR SPECIFICATIONS AS "N.I.C." OR "NOT IN CONTRACT", ALL ITEMS, MATERIALS, AND CONSTRUCTION SHOWN SHALL BE CONSIDERED PART OF THE RESPECTIVE CONTRACTS. REFER TO
"GENERAL CONDITIONS" OF THE CONTRACT DOCUMENTS.
ARCHITECTURAL HATCH SYMBOL LEGEND
CONCRETE MASONRY UNITS (PLAN)
CONCRETE
CRUSHED STONE
EARTH
WOOD FINISHED
WOOD ROUGH
BATT INSULATION
RIGID INSULATION
NOTE: GRAPHIC REPRESENTATIONS SHOWN BELOW ARE FOR GENERAL INFORMATION ONLY
BRICK (PLAN)
BRICK (ELEVATION)
HORIZONTAL LAP SIDING
SAND / GROUT / PARGING
PLYWOOD
GLASS
CONCRETE MASONRY UNITS (ELEVATION)
COPYRIGHT © 2025
BY SGS ARCHITECTS ENGINEERS,
INC. THIS DRAWING AND
INFORMATION IS AN INSTRUMENT
OF SERVICE AND SHALL NOT BE
COPIED OR USED IN ANY WAY
WITHOUT WRITTEN
AUTHORIZATION OF SGS. THIS
DRAWING NOT FOR GENERAL USE
AND ALL RIGHTS ARE RESERVED.
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS ON THE DRAWING
AND REPORT ANY ERROR TO
THE ARCHITECT BEFORE
STARTING WORK.
SHEET:
JOB NO.
DATE
CHECK
DRAWN
REVISIONS DATE
S C
A
LE
: 1 /8
1'
0"
0' 2'
8'
S C
A
LE
: 1 /4
1'
0"
0' 1'
2'
8'
S C
A
LE
: 3 /8
1'
0"
0' 1'
2'
6'
S C
A
LE
: 3 /4
1'
0"
0' 1'
2' 3'
S C
A
LE
: 1
/2
1'
0"
0" 6"
3"
S C
A
LE
: 3
1'
0"
0" 3"
6"
1"
2"
S C
A
LE
: 1
1'
0"
0" 6"
3"
R
EN
O V
A
TI
O N
S T
O
J
EN
N
IF
ER
C O
U R
T, S
U
IT
E 'E
C
A R
LI
S
LE
, P
A
(7
9-
C
IT
Y O
F H
A R
R S
IB
U
R G
S
TA
TI
O N
S
RAM
SEPTEMBER 11, 2026
25027
0-A-0.01
A R
C H
IT
EC
TU
R
A L
S Y
M B
O
LS
ET
C
H A
R R
IS
B
U R
G , P
A
DFS
ISSUED FOR PRICING
6"
9"
COLOR TO BE SELECTED BY
OWNER FROM MANUFACTURERS
FULL RANGE
ADA DETAILS / STANDARDS - ICC/ANSI A117.1-2009
M
IN
STANDARD TOILET STALL
TWO-HINGED DOORS IN SERIES
WHEELCHAIR TURNING SPACECLEAR FLOOR SPACE
DIMENSIONS OF ADULT-SIZED WHEELCHAIR
LATCH SIDE APPROACH-SWINGING DOOR
NOTE: Y = 54" MIN. IF DOOR HAS CLOSER
SIDE APPROACH-SWINGING DOOR
CLOSER AND LATCH
IF DOOR HAS BOTH A
NOTE: Y = 48" MIN.
HINGE SIDE APPROACH-SWINGING DOORFRONT APPROACH-SLIDING OR FOLDING DOORFRONT APPROACH-SWINGING DOORFRONT APPROACH-SWINGING DOOR
T-SHAPED SPACE FOR 180 TURNSTURNS AROUND AN OBSTRUCTION90 TURNSPACE NEEDED FOR U-TURN
DIMENSIONS OF ADULT-SIZED WHEELCHAIR
SPOUT HEIGHT AND KNEE CLEARANCE
PAPER TOWEL DISPENSERNAPKIN DISPOSALGRAB BARSTOILET TISSUE DISPENSER GRAB BARS
APPROACH
BRAILLE SIGN HEIGHTS
TEXT
TEXTTEXT
TEXT
ELECTRIC HAND DRYER
(59 FOR WALL HUNG)
APPROACH ONLY
42 MIN LATCH
-1
M
A X
M
A X
M
IN
M
IN
56 MIN
12 MAX
M
IN
42 MIN
48 MIN
60 MIN
17-19
24 MAX
48 MIN
M
IN
IN SHADED AREA
EQUIPMENT PERMITTED
8 MIN
M
IN
M
IN
6 MAX
17-19
M
A X
2424 7
RADIU
S31
Lc cL
CL
Y
X
PULL SIDE 24 MIN
M
IN
Y
PUSH SIDE
54 MIN
M
IN
X = 42" MIN. IF Y = 54"
NOTE: X = 36" MIN. IF Y = 60"
PULL SIDE
X
Y
M
IN
CLOSER AND LATCH
IF DOOR HAS BOTH A
NOTE: X = 12" MIN.
PUSH SIDE
X
M
IN
24 PREFERRED
PULL SIDE
18 MIN,
M
IN
M
IN
12 MIN12 MIN
M
IN
36 MIN
42 MINX42 MIN
M
IN
36 MIN48 MIN36 MIN
M
IN
78 MIN
M
IN
HANDLE
ARMREST
36 30
EYE LEVEL
LAP
SEAT
TOE
3-
FORWARD APPROACH
PARALLEL APPROACH
M A
X
TO
B A
SE
LI
N E
O F
TE
X
T
8"
M
IN
TO
B A
S
EL
IN
E
O F
B R
A
IL
LE
'-0
TOP OF
DISPENSING
OPENING OR TOP
OF CONTROLS
(WHICH -EVER IS
HIGHER)
2' -3
MIN.
3'-0"
24" MIN
42" MAX
M
IN
C ROLLL
12"
MAX
42"
M
IN
M A
X
MIN.
M
IN
1"
39"-41"
3' -1
M
A X
CL
M
IN
M A
X
FIRE
EXTINGUISHER
WALL HUNG
FIRE
EXTINGUISHER
IN RECESSED
CABINET
FIRE EXTINGUISHER MOUNTING HEIGHTS
EXIT SIGN
A/V
FIRE
ALARM
FIRE ALARM PULL
STATION
(GENERALLY
LOCATED UNDER
A/V ALARM)
MOUNTING HEIGHTS
7' -0
M
IN
6' -8
3' -6
12"
MIN
24" MIN.
1/
2" M
IN
B
EL
O W
G R
A B
B A
R
SE
E
EL
EC
. D
W G
S
FO
R
H
EI
G H
T
LIGHT
SWITCHES
OCCUPANCY
SENSOR
LL OS
CARD
READER
CR T
THERMOSTAT
SWITCHES AND CONTROLS - MOUNTING HEIGHTS - UON
" E
ELEC.
OUTLET
D
TEL /
DATA
TV
CATV
OUTLET
9"
MIRROR
0"
M A
X
B O
TT
O
M O
F R
EF
LE
C
TI
N G
U R
FA
C
E (N
O T
FR
A
M E)
General:
1. The Following Notes Are Provided for Clarification and Shall Not Limit Compliance or Relieve the Sub or General Contractor from Compliance with Other Provisions of the Locally Adopted ADA Codes and Amendments.
2. ADA Compliance Shall Require All Installations to Adhere to the Provisions of the 2010 ADA Standards for Accessible Design, State & Local Amendments, and the ICC/ANSI 117.1-2009. Where Discrepancies Exist Between This Document or the Provisions Contained Herein the Variation Shall Be Brought to the Attention of the Architect for Clarification.
3. Modifications of the Provisions Referenced Herein Shall Be Deemed Additional Requirements for Protection and Accessibility.
4. ICC-ANSI 606.6
A. There Will Be No Sharp or Abrasive Surfaces Permitted
Below Lavatories, Sinks or Countertops Intended for Approach by Wheelchairs.
B. Water Supply and Drainpipes Under Lavatories and Sinks Shall Be Insulated or Otherwise Configured to Protect Against Contact.
5. Provide All Horizontal / Vertical Bracing and Blocking for Fixtures and Bathroom Accessory Attachments. Coordinate with Owner for Owner Supplied Items.
6. Not All Details Shown May Apply.
Grab Bars:
1. ICC-ANSI 609.5 Grab Bars and Any Wall or Other Surfaces Adjacent to Grab Bars Shall Be Free of Sharp or Abrasive Elements. Edges Shall Have A Radius of 1/8 Inch Minimum.
2. ICC-ANSI 609.6 Grab Bars Shall Not Rotate Within Their Fittings.
3. ICC-ANSI 609.7 Grab Bars Shall Be Installed In Any Manner That
Provides A Gripping Surface At the Locations Specified In the ICC-ANSI Standard and That Does Not Obstruct the Clear Floor Space.
4. ICC-ANSI 609.8 Allowable Stresses In Bending, Shear, and Tension Shall Not Be Exceeded for Materials Used Where the Vertical or Horizontal Force of 250 Lbs Is Applied At Any Point On the Grab Bar, Fastener Mounting Device, or Supporting Structure.
5. All Grab Bars Shall Have A Penned Finish Gripping Surface.
Waterclosets:
1. Hand Operated Flush Controls Shall Comply with ADAAG 4.1.5
Lavatories:
1. Hand Operated Self-Closing Faucets Shall Remain Open for 10 Seconds Min.
2. Wrap / Insulate Hot & Cold-Water Lines and Drain Pipes At All Sink Locations Where Piping Is Exposed.
Signage:
1. Shall Comply with ICC-ANSI 703
2. ICC-ANSI 703.2.8 Shall Govern Mounting Location. When Sufficient
Space Is Available Signs Shall Be Located On the Latch Side of Single Doors and the Right Side of the Right Door for Double Doors. When Insufficient Space Is Available Signs Shall Be Located On the Nearest Adjacent Wall.
3. ICC-ANSI 703.28 Signs Containing Tactile Characters Shall Have An 18 Inch Square Min. Clear Ground Space Centered on the Sign, Beyond the Arc of Any Door Swing Between the Closed Position and 45 Degree Open Position.
ADA COMPLIANCE NOTES:
6"
9"
COLOR TO BE SELECTED BY
OWNER FROM MANUFACTURERS
FULL RANGE
6"
9"
COLOR TO BE SELECTED BY
OWNER FROM MANUFACTURERS
FULL RANGE
6"
9"
COLOR TO BE SELECTED BY
OWNER FROM MANUFACTURERS
FULL RANGE
COPYRIGHT © 2025
BY SGS ARCHITECTS ENGINEERS,
INC. THIS DRAWING AND
INFORMATION IS AN INSTRUMENT
OF SERVICE AND SHALL NOT BE
COPIED OR USED IN ANY WAY
WITHOUT WRITTEN
AUTHORIZATION OF SGS. THIS
DRAWING NOT FOR GENERAL USE
AND ALL RIGHTS ARE RESERVED.
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS ON THE DRAWING
AND REPORT ANY ERROR TO
THE ARCHITECT BEFORE
STARTING WORK.
SHEET:
JOB NO.
DATE
CHECK
DRAWN
REVISIONS DATE
S C
A
LE
: 1 /8
1'
0"
0' 2'
8'
S C
A
LE
: 1 /4
1'
0"
0' 1'
2'
8'
S C
A
LE
: 3 /8
1'
0"
0' 1'
2'
6'
S C
A
LE
: 3 /4
1'
0"
0' 1'
2' 3'
S C
A
LE
: 1
/2
1'
0"
0" 6"
3"
S C
A
LE
: 3
1'
0"
0" 3"
6"
1"
2"
S C
A
LE
: 1
1'
0"
0" 6"
3"
R
EN
O V
A
TI
O N
S T
O
J
EN
N
IF
ER
C O
U R
T, S
U
IT
E 'E
C
A R
LI
S
LE
, P
A
(7
9-
C
IT
Y O
F H
A R
R S
IB
U
R G
S
TA
TI
O N
S
RAM
SEPTEMBER 11, 2026
25027
0-A-0.02
TY
P
IC
A
L A
D A
D
ET
A
IL
S
H A
R R
IS
B
U R
G , P
A
DFS
3" = 1'-0"
1 DOOR SIGN #1
3" = 1'-0"
2 DOOR SIGN #2
3" = 1'-0"
3 DOOR SIGN #3
ISSUED FOR PRICING
AND PERMIT
09/11/2026
3" = 1'-0"
4 DOOR SIGN #4
WALL ASSEMBLIES
1. CONTRACTOR TO VERIFY AND INSTALL ALL
COMPONENTS PER LISTED ASSEMBLY.
2. ALL STUD SPACINGS LISTED IS MAXIMUM FOR
INTERIOR, EXTERIOR, AND RATED WALL ASSEMBLIES.
REFER TO STRUCTURAL DRAWINGS FOR STUD SPACING
ON ALL LOAD BEARING WALL ASSEMBLIES. STUDS
SMALLER THAN 3" SHALL HAVE A SPACING NOT GREATER
THAN 12" O.C.
3. ALL PENETRATIONS IN & THRU PARTITIONS WITH
SOUND BATT INSULATION SHALL BE SEALED WITH
APPROPRIATE SOUND SEALANT.
4. REFER TO DETAILS 16 & 17/0-A5.01 FOR ALL TOP OF WALL
DETAILS WHERE WALLS ARE INDICATED TO EXTEND TO
UNDERSIDE OF DECK.
5. ALL RATED PARTITIONS SHALL BE LABELED, ABOVE THE
CEILING WITH STENCILED LETTERS, 3 INCH HIGH MIN,
IN CONTRASTING COLOR TO THE WALL, EVERY 30 FEET
ON CENTER, AND WITHIN 5 FEET OF THE END OF THE
WALL, WITH THE FOLLOWING WORDING "FIRE AND/OR
SMOKE BARRIER - PROTECT ALL OPENINGS", VISIBLE
FROM ANYWHERE ABOVE THE CEILING.
6. REFER TO DETAILS 16 & 17/0-A-5.01 FOR DEFLECTION
TRACK DETAILS FOR ALL WALL PARTITIONS INDICATED
TO EXTEND TO UNDERSIDE OF DECK.
GENERAL NOTES:
5/8" GYPSUM WALLBOARD -
BOTH SIDES
3 5/8" x 20 GA METAL STUD
@ 16" O.C. MAX
3 5/8" x 20 GA METAL
STUD RUNNER CHANNEL
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
3 5/8" MINERAL WOOL
SOUND BATT INSULATION
CONTINUE PARTITION TO
UNDERSIDE OF DECK & SEAL
ALL VOIDS & PENETRATIONS -
REFER TO WALL SECTIONS FOR
TOP OF WALL DETAILS
5/8" GYPSUM WALLBOARD -
BOTH SIDES
3 5/8" x 20 GA METAL STUD
@ 16" O.C. MAX
3 5/8" x 20 GA METAL
STUD RUNNER CHANNEL
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
3 5/8" MINERAL WOOL
SOUND BATT INSULATION
8'
A .F
.F
1'
3 5/8" x 20 GA METAL
STUD RUNNER CHANNEL
5/8" GYPSUM BOARD
WALL CAP
GYP CORNER BEAD - BOTH
SIDES
5/8" GYPSUM WALLBOARD -
BOTH SIDES
3 5/8" x 20 GA METAL STUD
@ 16" O.C. MAX
3 5/8" x 20 GA METAL
STUD RUNNER CHANNEL
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
CONTINUE PARTITION TO
UNDERSIDE OF DECK & SEAL
ALL VOIDS & PENETRATIONS -
REFER TO WALL SECTIONS FOR
TOP OF WALL DETAILS
5/8" MOISTURE RESISTANT
GYPSUM WALLBOARD -
EXTEND TO 6" ABOVE CEILING
3 5/8" x 20 GA METAL STUD
@ 16" O.C. MAX - EXTEND
METAL STUDS TO 6" ABOVE
HIGHEST ADJACENT
CEILING
3 5/8" x 20 GA METAL STUD
RUNNER CHANNEL
SUSPENDED CEILING -
REFER TO RCP FOR TYPE &
HEIGHT
BASE - REFER TO
FINISH SCHEDULE
6"
5/8" MOISTURE RESISTANT
GYPSUM WALLBOARD -
EXTEND TO 6" ABOVE
CEILING - BOTH SIDES
3 5/8" x 20 GA METAL STUD
@ 16" O.C. MAX - EXTEND
METAL STUDS TO 6" ABOVE
HIGHEST ADJACENT
CEILING
3 5/8" x 20 GA METAL STUD
RUNNER CHANNEL
SUSPENDED CEILING -
REFER TO RCP FOR TYPE &
HEIGHT - BOTH SIDES
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
6"
5/8" GYPSUM WALLBOARD
6" x 20 GA METAL STUD @
16" O.C. MAX
6" x 20 GA METAL STUD
RUNNER CHANNEL
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
6" MINERAL WOOL SOUND
BATT INSULATION
CONTINUE PARTITION TO
UNDERSIDE OF DECK & SEAL
ALL VOIDS & PENETRATIONS -
REFER TO WALL SECTIONS FOR
TOP OF WALL DETAILS
5/8" TILE BACKER BOARD
B A
TH
R
O O
M S
ID
E
3 5/8" x 20 GA METAL STUD
@ 16" O.C. MAX
3 5/8" x 20 GA METAL
STUD RUNNER CHANNEL
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
3 5/8" MINERAL WOOL
SOUND BATT INSULATION
CONTINUE PARTITION TO
UNDERSIDE OF DECK & SEAL
ALL VOIDS & PENETRATIONS -
REFER TO WALL SECTIONS FOR
TOP OF WALL DETAILS
(N) CMU TO MATCH EXISTING
THICKNESS - 6" OR 4"
NOMINAL THICKNESS -
TOOTH-IN TO EXISTING
MASONRY
(N) 3/4" PLASTER TO
MATCH EXISTING -
FEATHER INTO EXISTING
5/8" MOISTURE RESISTANT
GYPSUM WALLBOARD -
EXTEND TO 6" ABOVE
CEILING - BOTH SIDES
6" x 20 GA METAL STUD @
16" O.C. MAX - EXTEND
METAL STUDS TO 6" ABOVE
HIGHEST ADJACENT
CEILING
6" x 20 GA METAL STUD
RUNNER CHANNEL
SUSPENDED CEILING -
REFER TO RCP FOR TYPE &
HEIGHT - BOTH SIDES
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
6"
(N) CMU TO MATCH EXISTING
THICKNESS - 6" OR 4"
NOMINAL THICKNESS -
TOOTH-IN TO EXISTING
MASONRY
(N) 3/4" PLASTER TO
MATCH EXISTING -
FEATHER INTO EXISTING
5/8" TYPE 'X' FIRE-RATED
GYPSUM WALLBOARD -
BOTH SIDES
3 5/8" x 20 GA METAL STUD
@ 16" O.C. MAX
1-HOUR FIRE-CAULKING -
BOTH SIDES - FULL DEPTH
OF WALL MATERIAL
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
3 5/8" MINERAL WOOL
SOUND BATT INSULATION
3 5/8" x 20 GA METAL
STUD RUNNER CHANNEL
1-HOUR RATED FIRE-PARTITION
UL# U419
SUSPENDED CEILING -
REFER TO RCP FOR TYPE &
HEIGHT
SCHLUTER JOLLY TRIM AT
BOTTOM EDGE OF TILE ABOVE
WALL BASE - MITRE ALL
CORNERS - SAND DOWN
ROUGH POINTS AT MITRE
LIQUID APPLIED WATER-
PROOFING
5/8" GYPSUM WALLBOARD
5/8" TILE BACKER BOARD
B A
TH
R
O O
M S
ID
E
SCHLUTER JOLLY TRIM AT
BOTTOM EDGE OF TILE ABOVE
WALL BASE - MITRE ALL
CORNERS - SAND DOWN
ROUGH POINTS AT MITRE
LIQUID APPLIED WATER
PROOFING
3 5/8" x 20 GA METAL STUD
@ 16" O.C. MAX - EXTEND
METAL STUDS TO 6" ABOVE
HIGHEST ADJACENT
CEILING
3 5/8" x 20 GA METAL STUD
RUNNER CHANNEL
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO
FINISH SCHEDULE
6"
5/8" TILE BACKER BOARD
SCHLUTER JOLLY TRIM AT
BOTTOM EDGE OF TILE ABOVE
WALL BASE - MITRE ALL
CORNERS - SAND DOWN
ROUGH POINTS AT MITRE
LIQUID APPLIED WATER-
PROOFING
B A
TH
R
O O
M S
ID
E
3 5/8" x 20 GA METAL STUD
@ 16" O.C. MAX - EXTEND
METAL STUDS TO 6" ABOVE
HIGHEST ADJACENT
CEILING
3 5/8" x 20 GA METAL STUD
RUNNER CHANNEL
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
6"
5/8" TILE BACKER BOARD
SCHLUTER JOLLY TRIM AT
BOTTOM EDGE OF TILE ABOVE
WALL BASE - MITRE ALL
CORNERS - SAND DOWN
ROUGH POINTS AT MITRE
LIQUID APPLIED WATER-
PROOFING
6" x 20 GA METAL STUD @
16" O.C. MAX - EXTEND
METAL STUDS TO 6" ABOVE
HIGHEST ADJACENT
CEILING
6" x 20 GA METAL STUD
RUNNER CHANNEL
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
6"
5/8" TILE BACKER BOARD
SCHLUTER JOLLY TRIM AT
BOTTOM EDGE OF TILE ABOVE
WALL BASE - MITRE ALL
CORNERS - SAND DOWN
ROUGH POINTS AT MITRE
LIQUID APPLIED WATER-
PROOFING
(E) CMU
(N) 3/4" PLASTER & LATH TO
MATCH EXISTING - FEATHER
INTO EXISTING - EXTEND TO
6" ABOVE CEILING
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO
FINISH SCHEDULE
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
6"
CONTINUE PARTITION TO
UNDERSIDE OF DECK & SEAL ALL
VOIDS & PENETRATIONS W/ 1-
HOUR RATED FIRE-CAULKING
5/8" TYPE 'X' FIRE-RATED
GYPSUM WALLBOARD
6" x 20 GA METAL STUD @
16" O.C. MAX
6" x 20 GA METAL STUD
RUNNER CHANNEL
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO FINISH
SCHEDULE - BOTH SIDES
6" MINERAL WOOL SOUND
BATT INSULATION
CONTINUE PARTITION TO
UNDERSIDE OF DECK & SEAL
ALL VOIDS & PENETRATIONS -
REFER TO WALL SECTIONS FOR
TOP OF WALL DETAILS
5/8" TILE BACKER BOARD
B A
TH
R
O O
M S
ID
E
SCHLUTER JOLLY TRIM AT
BOTTOM EDGE OF TILE ABOVE
WALL BASE - MITRE ALL
CORNERS - SAND DOWN
ROUGH POINTS AT MITRE
LIQUID APPLIED WATER-
PROOFING
1-HOUR RATED FIRE-PARTITION
UL# U419
5/8" TYPE 'X' FIRE-RATED GYPSUM
WALLBOARD ABOVE CEILING
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
LIQUID APPLIED WATER-
PROOFING
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
(E) CMU / PLASTER - WALL
CONSTRUCTION VARIES -
VERIFY IN FIELD
SUSPENDED CEILING - REFER
TO RCP FOR TYPE & HEIGHT
BASE - REFER TO
FINISH SCHEDULE
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
LIQUID APPLIED WATER-
PROOFING
CRACK ISOLATION MEMBRANE
CRACK ISOLATION MEMBRANE
CRACK ISOLATION MEMBRANE
CRACK ISOLATION MEMBRANE CRACK ISOLATION MEMBRANE
CRACK ISOLATION MEMBRANE
CRACK ISOLATION MEMBRANE
CRACK ISOLATION MEMBRANE
COPYRIGHT © 2025
BY SGS ARCHITECTS ENGINEERS,
INC. THIS DRAWING AND
INFORMATION IS AN INSTRUMENT
OF SERVICE AND SHALL NOT BE
COPIED OR USED IN ANY WAY
WITHOUT WRITTEN
AUTHORIZATION OF SGS. THIS
DRAWING NOT FOR GENERAL USE
AND ALL RIGHTS ARE RESERVED.
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS ON THE DRAWING
AND REPORT ANY ERROR TO
THE ARCHITECT BEFORE
STARTING WORK.
SHEET:
JOB NO.
DATE
CHECK
DRAWN
REVISIONS DATE
S C
A
LE
: 1 /8
1'
0"
0' 2'
8'
S C
A
LE
: 1 /4
1'
0"
0' 1'
2'
8'
S C
A
LE
: 3 /8
1'
0"
0' 1'
2'
6'
S C
A
LE
: 3 /4
1'
0"
0' 1'
2' 3'
S C
A
LE
: 1
/2
1'
0"
0" 6"
3"
S C
A
LE
: 3
1'
0"
0" 3"
6"
1"
2"
S C
A
LE
: 1
1'
0"
0" 6"
3"
R
EN
O V
A
TI
O N
S T
O
J
EN
N
IF
ER
C O
U R
T, S
U
IT
E 'E
C
A R
LI
S
LE
, P
A
(7
9-
RAM
SEPTEMBER 11, 2026
25027
0-A-0.03
TY
P
IC
A
L A
SS
EM
B
LI
ES
C
IT
Y O
F H
A R
R S
IB
U
R G
S
TA
TI
O N
S
H A
R R
IS
B
U R
G , P
A
DFS
ISSUED FOR PRICING
3/4" OSB COUNTERTOP W/
PLASTIC LAMINATE FACECAULK JOINT - WIPE
SMOOTH
WALL FINISH - REFER TO
FINISH SCHEDULE
CONT. 2x4 FRT WOOD BLOCKING -
PAINT TO MATCH WALL
RAKKS COUNTER SUPPORT,
EH1818, ANCHOR TO WALL AND
COUNTER PER MANUFACTURERS
WRITTEN INSTRUCTIONS - REFER
TO ELEVATIONS FOR SPACING
CONT. 2x6 FRT WOOD BLOCKING
BETWEEN STUDS - ENTIRE LENGTH
OF COUNTERTOP
2'
BASE - REFER TO
FINISH SCHEDULE
1/
2"
3"
2' - 1"
3/4" OSB THICKENED EDGE
W/ PLASTIC LAMINATE FACES
3/4" PLASTIC LAMINATE
BACK (SIDE) SPLASH
BASE - REFER TO FINISH SCHEDULE
1/2" SOLID SURFACE
COUNTERTOP W/
BUILT UP NOSING &
EASED EGDES
1/2" SOLID SURFACE BACK
(SIDE) SPLASH
CAULK JOINT - WIPE SMOOTH
CONT. 2x4 WOOD
BLOCKING
1/2" SOLID
SURFACE APRON
1/
2"
2'
2' - 1"
1"
WALL FINISH - REFER TO
FINISH SCHEDULE
2'
/2
CONT. 2x4 WOOD
BLOCKING
1/2" PLYWOOD
UNDERLAYMENT
CAULK JOINT - WIPE
SMOOTH
RAKKS COUNTER SUPPORT, EH1818,
ANCHOR TO WALL AND COUNTER
PER MANUFACTURERS WRITTEN
INSTRUCTIONS - REFER TO
ELEVATIONS FOR SPACING
BASE - REFER TO FINISH SCHEDULE
3/4" OSB COUNTERTOP W/
PLASTIC LAMINATE FACE
3/4" PLASTIC LAMINATE
BACK (SIDE) SPLASH
CAULK JOINT - WIPE
SMOOTH
CONT. 2x4 WOOD
BLOCKING
WALL FINISH - REFER TO
FINISH SCHEDULE
1/
2" 2'
/2
2'
2' - 1"
3"
RAKKS COUNTER SUPPORT, EH1818,
ANCHOR TO WALL AND COUNTER
PER MANUFACTURERS WRITTEN
INSTRUCTIONS - REFER TO
ELEVATIONS FOR SPACING
GWB CONTROL JOINT -
FILL W/ SEALANT
GYPSUM WALLBOARD
GYPSUM WALLBOARD
GWB CONTROL
JOINT - FILL W/
SEALANT
REFER TO PLANS
FOR WALL TYPE
1/2" TYP.
METAL STUDS @
16" O.C. U.N.O.
NOTE: - CONTROL JOINTS
SHALL BE 30'-0" O.C. MAX U.N.O.
(E) PREFINISHED ALUMINUM
STOREFRONT FRAMING SYSTEM
(N) PREFINISHED ALUMINUM
DRYWALL MOULDING END
CLOSURE TRIM - MULLION MATE
END CAP - MMEC-487 - FINISH TO
MATCH (E) ALUMINUM FRAMING
(N) 5/8" TYPE 'X' GYPSUM WALL
BOARD - BOTH SIDES
(N) DOUBLE STUDS FROM FLOOR
TO TOP OF WALL - REFER TO
WALL TYPE FOR WALL HEIGHT
(N) FIELD APPLIED GASKET W/
ADHESIVE
(E) WINDOW GLAZING
(N) FIRE-RATED DOOR & FRAME -
REFER TO PLAN / DOOR SCHEDULE
CENTER WALL ON EXISTING
MULLION
FACE OF WALL
WALL ANGLE
CUT EDGE OF PERIMETER CEILING TILE
TO MATCH TILE EDGE PROFILE - IF CORE
IS DIFFERENT COLOR THAN FACE, PAINT
CUT EDGE TO MATCH FACE COLOR
BASE - REFER TO FINISH SCHEDULE
1/2" SOLID SURFACE
COUNTERTOP W/
BUILT UP NOSING &
EASED EGDES
1/2" SOLID SURFACE BACK
(SIDE) SPLASH
CAULK JOINT - WIPE SMOOTH
CONT. 2x4 WOOD
BLOCKING
1/2" SOLID
SURFACE APRON
1/
2"
2'
1' - 9"
1"
WALL FINISH - REFER TO
FINISH SCHEDULE
2'
/2
CONT. 2x4 WOOD
BLOCKING
1/2" PLYWOOD
UNDERLAYMENT
CAULK JOINT - WIPE
SMOOTH
RAKKS COUNTER SUPPORT, EH1818,
ANCHOR TO WALL AND COUNTER
PER MANUFACTURERS WRITTEN
INSTRUCTIONS - REFER TO
ELEVATIONS FOR SPACING
REFER TO PLANS
FOR WALL TYPE
HM DOOR FRAME W/
DRYWALL RETURNS
METAL STUD HEADER
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH
SIDES
REFER TO PLANS
FOR WALL TYPE
HM DOOR FRAME W/
DRYWALL RETURNS
DOUBLE METAL JAMB STUDS
METAL STUD ANCHOR
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
REFER TO PLANS
FOR WALL TYPE
HM CASED OPENING
FRAME W/ DRYWALL
RETURNS
METAL STUD HEADER
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH
SIDES
REFER TO PLANS
FOR WALL TYPE
HM CASED OPENING FRAME
W/ DRYWALL RETURNS
DOUBLE METAL JAMB STUDS
METAL STUD ANCHOR
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
REFER TO PLANS
FOR WALL TYPE
HM DOOR FRAME W/ DRYWALL
RETURNS - INSTALLED OVER
CERAMIC TILE
METAL STUD HEADER
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH
SIDES
CERAMIC TILE - BOTH SIDES
REFER TO PLANS
FOR WALL TYPE
HM DOOR FRAME W/ DRYWALL
RETURNS - INSTALLED OVER
CERAMIC TILE
DOUBLE METAL JAMB STUDS
METAL STUD ANCHOR
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
CERAMIC TILE - BOTH SIDES
REFER TO PLANS
FOR WALL TYPE
HM DOOR FRAME W/ DRYWALL
RETURNS - INSTALLED OVER
CERAMIC TILE
METAL STUD HEADER
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH
SIDES
CERAMIC TILE - ONE SIDE -
VARIES
REFER TO PLANS
FOR WALL TYPE
HM DOOR FRAME W/ DRYWALL
RETURNS - INSTALLED OVER
CERAMIC TILE
DOUBLE METAL JAMB STUDS
METAL STUD ANCHOR
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
CERAMIC TILE - ONE SIDE - VARIES
ROOF DECK ASSEMBLY - REFER
TO SECTIONS & A-003
SLOTTED DEFLECTION TRACK -
3" LEG - 20 GUAGE - WIDTH TO
MATCH STUD ASSEMBLY
GYPSUM WALL BOARD - DO
NOT FASTEN THRU DEFLECTION
TRACK - NOR WITHIN 3" OF
EDGE OF DEFLECTION TRACK
METAL STUD - WIDTH VARIES -
REFER TO WALL ASSEMBLIES
ROOF DECK ASSEMBLY - REFER
TO SECTIONS & A-003
CLARK-DIETRICH BLAZE FRAME
(DSLW-2) DEFLECTION TRACK - 3" LEG -
20 GUAGE - WIDTH TO MATCH STUD
ASSEMBLY - OR APPROVED EQUAL
FIRE-RATED GYPSUM WALL
BOARD - DO NOT FASTEN THRU
DEFLECTION TRACK - NOR WITHIN
3" OF EDGE OF DEFLECTION TRACK
METAL STUD - WIDTH VARIES -
REFER TO WALL ASSEMBLIES
FILL DECK FLUTE WITH MINERAL
WOOL FIRE-SAFING INSULATION
CLARK-DIETRICH BLAZE FRAME
PERIMETER L-BEAD W/
COMPRESSIBLE FOAM - BOTH
SIDES OF WALL ASSEMBLY
6" = 1'-0"
2 ACT - WALL MOULDING DETAIL - TEGULAR
3" = 1'-0"
1 GWB CONTROL JOINT DETAIL - METAL STUDS
COPYRIGHT © 2025
BY SGS ARCHITECTS ENGINEERS,
INC. THIS DRAWING AND
INFORMATION IS AN INSTRUMENT
OF SERVICE AND SHALL NOT BE
COPIED OR USED IN ANY WAY
WITHOUT WRITTEN
AUTHORIZATION OF SGS. THIS
DRAWING NOT FOR GENERAL USE
AND ALL RIGHTS ARE RESERVED.
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS ON THE DRAWING
AND REPORT ANY ERROR TO
THE ARCHITECT BEFORE
STARTING WORK.
SHEET:
JOB NO.
DATE
CHECK
DRAWN
REVISIONS DATE
S C
A
LE
: 1 /8
1'
0"
0' 2'
8'
S C
A
LE
: 1 /4
1'
0"
0' 1'
2'
8'
S C
A
LE
: 3 /8
1'
0"
0' 1'
2'
6'
S C
A
LE
: 3 /4
1'
0"
0' 1'
2' 3'
S C
A
LE
: 1
/2
1'
0"
0" 6"
3"
S C
A
LE
: 3
1'
0"
0" 3"
6"
1"
2"
S C
A
LE
: 1
1'
0"
0" 6"
3"
R
EN
O V
A
TI
O N
S T
O
J
EN
N
IF
ER
C O
U R
T, S
U
IT
E 'E
C
A R
LI
S
LE
, P
A
(7
9-
RAM
SEPTEMBER 11, 2026
25027
0-A-5.01
TY
P
IC
A
L D
ET
A
IL
S
C
IT
Y O
F H
A R
R S
IB
U
R G
S
TA
TI
O N
S
H A
R R
IS
B
U R
G , P
A
DFS
1 1/2" = 1'-0"
4 WORK COUNTER DETAIL - STUD
1 1/2" = 1'-0"
5 VANITY COUNTER DETAIL
1 1/2" = 1'-0"
3 WORK COUNTER DETAIL - CMU
3" = 1'-0"
6 PARTITION @ ALUM FRAMING DETAIL
1 1/2" = 1'-0"
7 VANITY COUNTER DETAIL - SHORT
3" = 1'-0"
8 HEAD DETAIL
3" = 1'-0"
9 JAMB DETAIL
3" = 1'-0"
10 HEAD DETAIL
3" = 1'-0"
11 JAMB DETAIL
3" = 1'-0"
12 HEAD DETAIL
3" = 1'-0"
13 JAMB DETAIL
3" = 1'-0"14 HEAD DETAIL
3" = 1'-0"15 JAMB DETAIL
1 1/2" = 1'-0"16 TYPICAL DEFLECTION TRACK DETAIL
1 1/2" = 1'-0"17 FIRE-RATED DEFLECTION TRACK DETAIL
ISSUED FOR PRICING
REFER TO PLANS
FOR WALL TYPE
HM DOOR FRAME W/
DRYWALL RETURNS
(E) CMU
(E) PLASTER & LATH - PATCH AND
REPAIR AS REQUIRED - BOTH SIDES
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
REFER TO PLANS
FOR WALL TYPE
HM DOOR FRAME W/
DRYWALL RETURNS
CMU INFILL - MATCH EXISTING
THICKNESS - TOOTH-IN
PLASTER & LATH - THICKNESS TO
MATCH EXISTING - BOTH SIDES
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
REFER TO PLANS
FOR WALL TYPE
HM DOOR FRAME W/
DRYWALL RETURNS
CMU INFILL - MATCH EXISTING
THICKNESS - TOOTH-IN
PLASTER & LATH - THICKNESS TO
MATCH EXISTING
CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
REFER TO PLANS
FOR WALL TYPE
(N) HM / GHM DOOR FRAME W/
DRYWALL RETURNS - REFER TO
PLANS / DOOR SCHED.
(E) CMU
(E) PLASTER & LATH - PATCH AND
REPAIR AS REQUIRED - BOTH SIDES
(N) CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
(E) HEADER
(N) DOOR - REFER TO PLANS AND
DOOR SCHEDULE FOR SIZE & TYPE
REFER TO PLANS
FOR WALL TYPE
(N) HM / GHM DOOR FRAME W/
DRYWALL RETURNS - REFER TO
PLANS / DOOR SCHED.
(E) CMU - CUT AS REQUIRED TO
INSTALL NEW ANGLE HEADER
(E) PLASTER & LATH - PATCH AND
REPAIR AS REQUIRED - BOTH SIDES
(N) CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
(N) GALV. STEEL ANGLE HEADER -
TWO (2) L3"x2.5"x0.25" - EXTEND
4" BEYOND OPENING EACH SIDE
(N) DOOR - REFER TO PLANS AND
DOOR SCHEDULE FOR SIZE & TYPE
REFER TO PLANS
FOR WALL TYPE
(N) HM / GHM DOOR FRAME W/
DRYWALL RETURNS - REFER TO
PLANS / DOOR SCHED.
(E) CMU
(E) PLASTER & LATH - PATCH AND
REPAIR AS REQUIRED
(N) CAULKING AROUND ENTIRE
FRAME PERIMETER - BOTH SIDES
(E) HEADER
(N) DOOR - REFER TO PLANS AND
DOOR SCHEDULE FOR SIZE & TYPE
R
EF
ER
T
O F
IN
IS
H S
C H
E D
U
LE
RADIUS (PER MANUF.
WRITTEN REQUIREMENTS)
SEAMLESS EPOXY
FLOORING - THICKNESS
PER SPECIFICATIONS
ALUMINUM COVE CAP STRIP -
FINISH TO BE SELECTED BY
ARCHITECT FROM FULL LINE
SEAMLESS EPOXY INTEGRAL
BASE - THICKNESS PER
SPECIFICATIONS
R
EF
ER
T
O F
IN
IS
H S
C H
E D
U
LE
RADIUS (PER MANUF.
WRITTEN REQUIREMENTS)
SEAMLESS EPOXY
FLOORING - THICKNESS
PER SPECIFICATIONS
ALUMINUM COVE CAP STRIP -
FINISH TO BE SELECTED BY
ARCHITECT FROM FULL LINE
SEAMLESS EPOXY INTEGRAL
BASE - THICKNESS PER
SPECIFICATIONS
5/8" TILE BACKER BOARD
SCHLUTER JOLLY TRIM AT
BOTTOM EDGE OF TILE ABOVE
WALL BASE - MITRE ALL
CORNERS - SAND DOWN
ROUGH POINTS AT MITRE
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
APPLY AT JOINT, JOINT
COMPOUND AND JOINT TAPE
MOLDING ANGLE, SECURE TO WALL
WITH APPROPRIATE FASTENER,
TYPICAL.
SCREW GYPSUM BOARD TO
ANGLE MOLDING
GWB CASING BEAD
5/8" MOISTURE RESISTANT
GYPSUM WALLBOARD
GYPSUM BOARD
SUSPENSION CROSS TEE
GYPSUM BOARD
SUSPENSION MAIN TEE
HANGER WIRE
3/8" BACKER ROD & SEALANT
3/8"
PREFINISHED FULLY
ADHERED FRP PANEL
PREFINISHED FRP J-CHANNEL -
FULLY ADHERED
ALUMINUM MATERIAL BREAK -
COLOR AS SELECTED BY ARCH -
CENTERED UNDER DOOR
V.C.T. FLOORING
SEAMLESS EPOXY FLOORING
CONCRETE SLAB
5/8" TILE BACKER BOARD
SCHLUTER RONDEC TRIM
AT ALL VERTICAL
OUTSIDE CORNERS
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
5/8" TILE BACKER BOARD
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
5/8" TILE BACKER BOARD
SCHLUTER DILEX-AHK
TRIM AT ALL VERTICAL
INSIDE CORNERS
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
CERAMIC WALL TILE - REFER
TO FINISH SCHEDULE
1. CONTRACTOR TO VERIFY AND INSTALL ALL COMPONENTS PER LISTED ASSEMBLY.
2. ALL STUD SPACINGS LISTED IS MAXIMUM FOR INTERIOR, EXTERIOR, AND RATED WALL ASSEMBLIES.
REFER TO STRUCTURAL DRAWINGS FOR STUD SPACING ON ALL LOAD BEARING WALL ASSEMBLIES.
STUDS SMALLER THAN 3" SHALL HAVE A SPACING NOT GREATER THAN 12" O.C.
3. ALL PENETRATIONS IN & THRU PARTITIONS WITH SOUND BATT INSULATION SHALL BE SEALED
WITH APPROPRIATE SOUND SEALANT.
4. REFER TO DETAILS 16 & 17/0-A5.01 FOR ALL TOP OF WALL DETAILS WHERE WALLS ARE INDICATED
TO EXTEND TO UNDERSIDE OF DECK.
5. ALL RATED PARTITIONS SHALL BE LABELED, ABOVE THE CEILING WITH STENCILED LETTERS, 3 INCH HIGH MIN, IN CONTRASTING COLOR TO THE WALL, EVERY 30 FEET ON CENTER, AND WITHIN 5 FEET
OF THE END OF THE WALL, WITH THE FOLLOWING WORDING "FIRE AND/OR SMOKE BARRIER -
PROTECT ALL OPENINGS", VISIBLE FROM ANYWHERE ABOVE THE CEILING.
6. REFER TO DETAILS 16 & 17/0-A-5.01 FOR DEFLECTION TRACK DETAILS FOR ALL WALL PARTITIONS
INDICATED TO EXTEND TO UNDERSIDE OF DECK.
GENERAL NOTES:
FLOOR ASSEMBLIES
F-A
LOAD BEARING
FIRE RATING: NONE
(N) FLOOR FINISH - REFER TO FINISH SCHEDULE
(N) CAST-IN-PLACE CONCRETE SLAB - 4,000 PSI -
W/ 6x6 W2.1xW2.1 WWF IN CENTER OF SLAB -
MATCH EXISTING SLAB THICKNESS
(E) COMPACTED FILL
(E) UNDISTURBED / COMPACTED SOIL
(N) CONT. 10 MIL POLYETHYLENE UNDERSLAB
VAPOR BARRIER - TAPE ALL SEAMS /
PENETRATIONS. LAP MINIMUM 6" AT ALL
JOINTS
(E) CONCRETE SLAB
(E) VAPOR BARRIER
(N) COMPACTED SUBBASE - CRUSHED 2B STONE -
THICKNESS TO MATCH EXISTING - 4" MIN
(N) 6" LONG x #3 REBAR @ 36" O.C. MAX (BOTH
SIDES OF TRENCH) - SET IN EPOXY @ CENTER
HEIGHT OF EXISTING SLAB
COPYRIGHT © 2025
BY SGS ARCHITECTS ENGINEERS,
INC. THIS DRAWING AND
INFORMATION IS AN INSTRUMENT
OF SERVICE AND SHALL NOT BE
COPIED OR USED IN ANY WAY
WITHOUT WRITTEN
AUTHORIZATION OF SGS. THIS
DRAWING NOT FOR GENERAL USE
AND ALL RIGHTS ARE RESERVED.
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS ON THE DRAWING
AND REPORT ANY ERROR TO
THE ARCHITECT BEFORE
STARTING WORK.
SHEET:
JOB NO.
DATE
CHECK
DRAWN
REVISIONS DATE
S C
A
LE
: 1 /8
1'
0"
0' 2'
8'
S C
A
LE
: 1 /4
1'
0"
0' 1'
2'
8'
S C
A
LE
: 3 /8
1'
0"
0' 1'
2'
6'
S C
A
LE
: 3 /4
1'
0"
0' 1'
2' 3'
S C
A
LE
: 1
/2
1'
0"
0" 6"
3"
S C
A
LE
: 3
1'
0"
0" 3"
6"
1"
2"
S C
A
LE
: 1
1'
0"
0" 6"
3"
R
EN
O V
A
TI
O N
S T
O
J
EN
N
IF
ER
C O
U R
T, S
U
IT
E 'E
C
A R
LI
S
LE
, P
A
(7
9-
RAM
SEPTEMBER 11, 2026
25027
0-A-5.02
TY
P
IC
A
L D
ET
A
IL
S
C
IT
Y O
F H
A R
R S
IB
U
R G
S
TA
TI
O N
S
H A
R R
IS
B
U R
G , P
A
DFS
3" = 1'-0"2 JAMB DETAIL
3" = 1'-0"4 JAMB DETAIL
3" = 1'-0"6 JAMB DETAIL
3" = 1'-0"
1 HEAD DETAIL
3" = 1'-0"
3 HEAD DETAIL
3" = 1'-0"
5 HEAD DETAIL
6" = 1'-0"8 EPOXY COVE BASE DETAIL AT CERAMIC TILE
6" = 1'-0"
7 EPOXY COVE BASE DETAIL
6" = 1'-0"
9 GYPSUM BOARD SUSPENDED CEILING DETAIL
ISSUED FOR PRICING
AND PERMIT
09/11/2026
12" = 1'-0"
10 SEAMLESS EPOXY TO VCT TRANSITION
6" = 1'-0"
11 CERAMIC TILE VERTICAL OUTSIDE CORNER
6" = 1'-0"12 CERAMIC TILE VERTICAL INSIDE CORNER
NOTE:
NOT ALL ABBREVIATIONS AND SYMBOLS INDICATED
MAY APPEAR ON THESE CONTRACT DRAWINGS.
THIS IS FOR REFERENCE ONLY.
ABBREVIATIONS
A/C
AFF
AFG
AMB
AMP
AP
APROX
ARR
ATC
AUTO
AUX
AVG
BF
BHP
BOD
BOP
BOT
BP
BSMT
BTU
CA
CAP
CF
CFM
CL
CO
COL
CONC
CONN
CONT
CTR
D
DB
DDC
DEG
DET
DIA
DISC
DN
DWG
EA
EAT
EER
EFF
EJ
EL
ELEC
ENT
ESP
EVAP
EWT
EXH
EXP
EXST
EXT
F&T
FC
FDW
FLA
FLR
FO
FPM
FPS
FS
FT
GA
GAL
GALV
GND
GPH
GPM
GR
HD
HG
HGT
HMD
HORIZ
HP
HTD
HTR
AIR CONDITIONING
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMBIENT
AMPERE
ACCESS PANEL
APPROXIMATE
ARRANGEMENT
AUTOMATIC TEMPERATURE CONTROL
AUTOMATIC
AUXILIARY
AVERAGE
BOILER FEED
BRAKE HORSEPOWER
BOTTOM OF DUCT
BOTTOM OF PIPE
BOTTOM
BACK PRESSURE
BASEMENT
BRITISH THERMAL UNIT
COMPRESSED AIR
CAPACITY
CUBIC FOOT (FEET)
CUBIC FOOT (FEET) PER MINUTE
CENTER LINE
CLEANOUT
COLUMN
CONCRETE OR CONCENTRIC
CONNECT OR CONNECTION
CONTINUATION
CENTER
DRAIN OR DEEP
DRY BULB
DIRECT DIGITAL CONTROL
DEGREE
DETAIL
DIAMETER
DISCONNECT
DOWN
DRAWING
EACH
ENTERING AIR TEMPERATURE
ENERGY EFFICIENCY RATIO
EFFICIENCY
EXPANSION JOINT
ELEVATION
ELECTRICAL
ENTERING
EXTERNAL STATIC PRESSURE
EVAPORATOR
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
EXISTING
EXTERNAL
FLOAT & THERMOSTATIC
FLEXIBLE CONNECTION
FEED WATER
FULL LOAD AMPS
FLOOR
FUEL OIL
FOOT (FEET) PER MINUTE
FOOT (FEET) PER SECOND
FLOW SWITCH
FOOT (FEET)
GAUGE
GALLONS
GALVANIZED
GROUND
GALLONS PER HOUR
GALLONS PER MINUTE
GRAIN
HEAD
HOT GAS
HEIGHT
HUMIDITY
HORIZONTAL
HORSEPOWER
HEATED
HEATER
Hz
INSUL
INTL
LAT
LBS
LIN
LP
LRA
LVL
LVR
LWT
MAN
MAX
MBH
MIN
MOD
MTD
MU
NA
NC
NEG
NIC
NO
NTS
OA
OED
OFCI
OV
PCR
PD
PG
PL
PNEU
PRESS
PROP
PSIG
QTY
REF
REQD
REV
RL
RM
RS
RTN
S
SCH
SD
SEC
SENS
SEP
SEQ
SER
SERV
SHT
SOL
SP
SPLY
SS
STL
SUCT
TD
TEMP
TH
THK
TSP
TYP.
UON
V
VAC
VAV
VB
VEL
VERT
VIB
VOL
VSD
VTR
W
WB
WMS
HERTZ
INSULATION
INTERNAL
LEAVING AIR TEMPERATURE
POUNDS
LINEAL
LOW PRESSURE
LOCKED ROTOR AMPS
LEVEL
LOUVER
LEAVING WATER TEMPERATURE
MANUAL
MAXIMUM
THOUSAND BRITISH THERMAL UNITS PER HOUR
MINIMUM
MODEL
MOUNTED
MAKEUP
NOT APPLICABLE
NORMALLY CLOSED
NEGATIVE
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OPEN END DUCT
OWNER FURNISHED CONTRACTOR INSTALLED
OUTLET VELOCITY
PUMPED CONDENSATE RETURN
PRESSURE DROP
RESSURE GAUGE
PLATE
PNEUMATIC
PRESSURE
PROPELLER
POUNDS PER SQUARE INCH GAUGE
QUANTITY
REFERENCE
REQUIRED
REVISION
REFRIGERANT LIQUID
ROOM
REFRIGERANT SUCTION
RETURN
SWITCH
SCHEDULE
SMOKE DAMPER
SECONDARY SECONDS
SENSIBLE
SEPARATE
SEQUENCE
SERIES
SERVICE
SHEET
SOLENOID
STATIC PRESSURE
SUPPLY
STAINLESS STEEL
STEEL
SUCTION
TEMPERATURE DIFFERENTIAL
TEMPERATURE
THERMOMETER
THICK
TOTAL STATIC PRESSURE
TYPICAL
UNLESS OTHERWISE NOTED
VENT OR VOLT
VACUUM
VARIABLE AIR VOLUME
VACUUM BREAKER
VELOCITY
VERTICAL
VIBRATION
VOLUME
VARIABLE SPEED DRIVE
VENT THRU ROOF
WATT, WIDTH OR WIDE
WET BULB
WIRE MESH SCREEN
SYMBOL DESCRIPTION
SHUT-OFF VALVE
GLOBE VALVE
CHECK VALVE
FLOW SETTER
ANGLE GATE VALVE
RELIEF OR SAFETY VALVE
SOLENOID VALVE
BUTTERYFLY VALVE
2-WAY CONTROL VALVE
3-WAY CONTROL VALVE
PRESSURE REDUCING VALVE
UNION
STRAINER W/BLOW-OFF & CAP
PIPE GUIDE
PIPE ANCHOR
FLEXIBLE CONNECTOR
EXPANSION JOINT
THERMOMETER
PRESSURE GAUGE W/COCK
AUTOMATIC AIR VENT
MANUAL AIR VENT
DIRECTION OF FLOW
DIRECTION OF SLOPE
CONCENTRIC REDUCER
ECCENTRIC REDUCER
PIPE UP
PIPE DOWN
PIPE THROUGH
TOP TAKE-OFF
EXISTING TO REMAIN
EXISTING TO BE REMOVED
NEW WORK
BOILER FEED WATER
COMPRESSED AIR
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CONDENSATE DRAIN OR DRAIN
FUEL OIL RETURN
FUEL OIL SUPPLY
FUEL OIL TANK VENT
HOT GAS
HIGH PRESSURE CONDENSATE RETURN
HIGH PRESSURE STEAM SUPPLY
HEATING WATER RETURN
HEATING WATER SUPPLY
LOW PRESSURE CONDENSATE RETURN
LOW PRESSURE STEAM SUPPLY
MEDIUM PRESSURE CONDENSATE RETURN
MEDIUM PRESSURE STEAM SUPPLY
PUMPED CONSENSATE RETURN
REFRIGERANT LIQUID
REFRIGERANT SUCTION
VENT LINE
PIPING SYMBOLS
A
M
36x14Ø
UP DN
24x36
DOUBLE LINE
ROUND DUCT UP
45°ELBOW (NO VANES)
DIRECTION OF FLOW
ROUND DUCT DOWN
36x14Ø
UP DN
24x36
SINGLE LINE
NEW WORK
SUPPLY AIR DOWN
SUPPLY AIR UP
EXISTING TO BE REMOVED
EXISTING TO REMAIN
DESCRIPTION
4-WAY DIFFUSER
EXHAUST OR RETURN GRILLE
FLAT OVAL DUCT SIZE
(FIRST FIGURE-SIDE SHOWN)
DUCT INCLINED RISE OR DROP
IN DIRECTION OF FLOW
90° ELBOW WITH
TURNING VANES
SUPPLY OR RETURN BRANCH CONNECTION
SUPPLY BRANCH WITH SPIN
COLLAR CONNECTION
LATERAL CONNECTION
ROUND DUCTWORK
CONICAL TEE ROUND DUCTWORK
EXHAUST OR RETURN AIR UP
EXHAUST OR RETURN AIR DOWN
DUCTWORK SYMBOLS
3-WAY, 2-WAY, OR 1-WAY GRILLE
RECTANGULAR DUCT SIZE SHOWN IN
INCHES (FIRST FIGURE-SIDE SHOWN)
DUCT SMOKE DETECTOR SDT
MOTORIZED DAMPER
BACK DRAFT DAMPER
VOLUME DAMPER
MD
FLEXIBLE DUCTWORK
(DUCT PRESSURE CLASS)
SMOKE DAMPER WITH ACCESS DOOR
FIRE DAMPER WITH ACCESS DOOR
COMBINATION FIRE & SMOKE
DAMPER WITH ACCESS DOOR
MD
BDD BDD
BYPASS DAMPER
BD BD
STATIC PRESSURE SENSOR
SP SP
POINT OF CONNECTION-NEW TO EXISTING
H HUMIDISTAT
DRAWING NOTE SYMBOL
REVISION SYMBOL
# SECTION NUMBER
# DETAIL OR SECTION NUMBER
DIRECTION OF VIEW
MISCELLANEOUS SYMBOLS
T THERMOSTAT
DRAWING FROM WHICH SECTION
OR DETAIL IS TAKEN
DRAWING ON WHICH SECTION
OR DETAIL IS SHOWN
S SWITCH
POINT OF DEMOLITION CONCLUSION
CWS
V
LPR
LPS
PCR
MPS
RS
RL
MPR
FOR
FOS
HG
FOV
HPR
HPS
HWR
HWS
CD
CHWR
CA
BF
CHWS
CWR
VFD (VARIABLE FREQUENCY DRIVE)
RUNOUT SCHEDULE
FLEXIBLE DUCT
SCHEDULE
0.0 - 3.0
3.1 - 6.5
6.6 - 11.5
11.6 - 18.5
18.6 - 40.0
40.1 - 69.0
69.1 - 122.0
3/4"
1"
1 1/4"
1 1/2"
2"
2-1/2"
3"
GPM PIPE SIZE
CFM
UP TO 125
126 TO 280
281 TO 380
381 TO 550
551 TO 750
DUCT DIAMETER
6"
8"
10"
12"
14"
122.1 - 255.0 4"
255.1 - 750.0 6"
S*
AIR TERMINAL DESIGNATION
AIR TERMINAL NECK SIZE
AIR TERMINAL CFM
DOUBLE-WALL SPIRAL DUCT
(COLOR SHALL BE SELECTED BY ARCHITECT)
MEDIUM PRESSURE DUCTWORK
D
12x10
12x10 12x10
12x10
COPYRIGHT © 2025
BY SGS ARCHITECTS ENGINEERS,
INC. THIS DRAWING AND
INFORMATION IS AN INSTRUMENT
OF SERVICE AND SHALL NOT BE
COPIED OR USED IN ANY WAY
WITHOUT WRITTEN
AUTHORIZATION OF SGS. THIS
DRAWING NOT FOR GENERAL USE
AND ALL RIGHTS ARE RESERVED.
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS ON THE DRAWING
AND REPORT ANY ERROR TO
THE ARCHITECT BEFORE
STARTING WORK.
SHEET
JOB NO.
DATE
CHECK
DRAWN
REVISIONS DATE
S C
A L E
/8
S C
A L E
/4
S C
A L E
/8
S C
A L E
/4
S C
A L E
/2
S C
A L E
S C
A L E
R E
N O
V A
T
IO
N
A D
D
IT
IO
N
T O
J
E N
N
IF
E R
C O
U R
T S
U
IT
E 'E
C
A R
L
IS
L E
P
A
(7
-4
RWR
SEPTEMBER 11, 2026
25027
0-M-0.01
M E
C H
A N
IC
A
L I N
F O
R M
A T
IO
N
S H
E E
T
C
IT
Y O
F H
A R
R S
IB
U
R G
S
T A
T
IO
N S
H A
R R
IS
B
U R
G P
A
SRA
MECHANICAL DRAWING LIST
0-M-0.01 MECHANICAL INFORMATION SHEET
0-M-0.02 MECHANICAL GENERAL NOTES, SCHEDULES, & DETAILS
1-MD-1.01 STATION 1 - ENLARGED PLANS - DEMOLITION - MECHANICAL
1-M-1.01 STATION 1 - OVERALL FIRST FLOOR PLAN - MECHANICAL DUCT
1-M-1.02 STATION 1 - ENLARGED PLANS - MECHANICAL DUCT
2-MD-1.01 STATION 2 - ENLARGED PLANS - DEMOLITION - MECHANICAL
2-M-1.01 STATION 2 - OVERALL FIRST FLOOR PLAN - MECHANICAL DUCT
2-M-1.02 STATION 2 - ENLARGED PLANS - MECHANICAL DUCT
1 ISSUED FOR PRICING
1. ALL WORK AND EQUIPMENT SHALL COMPLY WITH ALL APPLICABLE LAWS, CODES, AND
REQUIREMENTS; OF ALL AUTHORITIES HAVING JURISDICTION, INCLUDING BUT NOT
LIMITED TO THE INTERNATIONAL MECHANICAL CODE, THE INTERNATIONAL PLUMBING
CODE, THE INTERNATIONAL ENERGY CODE, THE LOCAL FIRE MARSHALL, UNDERWRITERS
LABORATORY, IRI, FM, OSHA, AND THE NATIONAL ELECTRICAL CODE. MODIFICATIONS
REQUIRED BY THE ABOVE AUTHORITIES IN ORDER TO BRING THE PROJECT INTO CODE
COMPLIANCE SHALL BE MADE AT NO ADDITIONAL COST TO OWNER. IF CONTRACT
DOCUMENTS ARE MORE STRINGENT THAN CODE REQUIREMENTS, THE CONTRACT
DOCUMENTS SHALL GOVERN.
2. ALL SPECIFICATIONS AND DRAWINGS ARE COMPLIMENTARY AND MUST BE USED IN
COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. ANY CONFLICTING
INFORMATION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER, AND WORK
SHALL CEASE ON THAT PORTION OF THE PROJECT UNTIL CLARIFICATIONS ARE ISSUED.
3. HEATING CONTRACTOR (H.C.) AND MECHANICAL CONTRACTOR (M.C.) TERMINOLOGY IS
INTERCHANGEABLE.
4. CONTRACTOR SHALL COORDINATE, PREPARE AND SUBMIT SHOP DRAWINGS TO THE
ARCHITECT AND ENGINEER FOR APPROVAL. SHOP DRAWINGS TO BE SUBMITTED
INCLUDE: SHEET METAL, DIFFUSERS, GRILLES, REGISTERS, FIRE DAMPERS, AND ALL
EQUIPMENT. SHEET METAL SHOP DRAWINGS SHALL BE COORDINATED AND SHOW DUCT
ELEVATIONS. INCLUDE RISES, DROPS, AND OFFSETS TO PROVIDE A COMPLETE AND
FUNCTIONAL SYSTEM. AREAS OF POTENTIAL CONFLICT SHALL BE BROUGHT TO THE
ENGINEER'S ATTENTION.
5. A SET OF MEP RECORD/COORDINATION DRAWINGS SHALL BE MAINTAINED BY THE
CONTRACTOR AT THE JOB SITE. ACTUAL LOCATIONS OF ALL EQUIPMENT, PIPING,
DUCTWORK, AND ALL OTHER ITEMS INCLUDED IN THIS CONTRACT, AND ALL DEVIATIONS
OF THE WORK FROM THAT SHOWN ON THE CONTRACT DOCUMENTS SHALL BE MARKED
ON THE RECORD/COORDINATION DRAWINGS. EACH TRADE SHALL REVIEW THE
COORDINATION DRAWINGS AND RESOLVE ANY POTENTIAL CONFLICTS WITH OTHER
TRADES PRIOR TO INSTALLING ANY PORTION OF THEIR WORK.
6. THE MECHANICAL CONTRACTOR SHALL SUBMIT TO THE ARCHITECT/ENGINEER AS-BUILT
DRAWINGS AND OPERATION AND MAINTENANCE MANUALS INCLUDING ALL NAMEPLATE
DATA, WIRING DIAGRAMS, MAINTENANCE INSTRUCTIONS, AND PARTS LIST UPON PROJECT
COMPLETION.
7. WORK SHALL BE EXECUTED IN A GOOD WORKMANLIKE MANNER USING MECHANICS IN
THEIR RESPECTIVE TRADES. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR
COORDINATING THE WORK UNDER THIS CONTRACT. UPON COMPLETION OF
CONSTRUCTION, THE CONTRACTOR SHALL DELIVER COMPLETE AND FUNCTIONAL
SYSTEMS AS ENCOMPASSED BY THE CONTRACT. ALL EQUIPMENT SHALL BE INSTALLED
PER MANUFACTURER'S RECOMMENDATIONS AND CODE REQUIREMENTS.
8. THE HVAC CONTRACTOR SHALL ARRANGE THE PROGRESS OF HIS WORK SO AS TO
CONFORM TO THE PROGRESS OF THE TRADES AND SHALL COMPLETE THE ENTIRE
INSTALLATION AS SOON AS THE CONDITION OF THE PROJECT WILL PERMIT.
9. ALL TEMPERATURE CONTROL SYSTEM WORK AND INSPECTION SHALL BE ACCOMPLISHED
BY THIS CONTRACTOR. THERMOSTATS SHALL BE INSTALLED IN CLOSE PROXIMITY TO
RETURN AIR INLETS UNDER THIS CONTRACT. STANDARD MOUNTING HEIGHT TO TOP OF
THERMOSTAT IS 48" ABOVE FINISHED FLOOR OR AS INDICATED ON THE ARCHITECTURAL
DRAWINGS. COORDINATE ALL LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN AND
INSTALLATION. DO NOT INSTALL THERMOSTATS NEAR DIMMER SWITCHES. WIRING OF ALL
MOTORIZED OPERATORS AND THERMOSTATS, REGARDLESS OF VOLTAGE ARE THE
RESPONSIBILITY OF THE MECHANICAL CONTRACTOR.
10. MECHANICAL CONTRACTOR SHALL COORDINATE ALL SENSOR MOUNTING LOCATIONS
WITH INTERIORS DRAWINGS.
11. THE CONTRACTOR SHALL PROVIDE ADEQUATE CLEARANCE FOR ALL UNIT CONTROLS.
12. CONTRACTOR SHALL MAKE ALL FINAL EQUIPMENT CONNECTIONS AND PROVIDE THE
NECESSARY ADAPTERS, FITTINGS, VALVES, AND DEVICES FOR A COMPLETE OPERABLE
SYSTEM. COORDINATE REQUIREMENT FOR PROVISION OF CONTACTORS AND CONTROL
WIRING FOR PROPER FUNCTIONING SYSTEM WITH ELECTRICAL CONTRACTOR. MOTOR
STARTERS, COMBINATION MOTOR STARTERS, AND DISCONNECTS ARE TO BE PROVIDED
BY THIS CONTRACTOR FOR INSTALLATION BY OTHERS.
13. CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE RELATION OF PIPING,
DUCTWORK, CONNECTIONS, AND EQUIPMENT. CONTRACTOR SHALL TAKE ALL
INTERFERENCES INTO CONSIDERATION. PROVIDE ALL NECESSARY OFFSETS OR
TRANSITIONS WITH EQUIVALENT AREAS TO MATCH DUCT SIZES AS INDICATED ON
DRAWINGS. ALL PIPING AND DUCTWORK TO BE CONCEALED IN CEILINGS AND WALLS,
EXCEPT IN MECHANICAL ROOMS, SPACES WITHOUT CEILINGS, OR WHERE NOTED
OTHERWISE.
14. COORDINATE INSTALLATION OF NEW WORK WITH ARCHITECTURAL PLANS, STRUCTURAL
PLANS, AND LIGHTING PLANS. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS
FOR CEILING TYPES AND LOCATIONS OF ALL GRILLES AND DIFFUSERS. PROVIDE
APPROPRIATE FRAMES AND MOUNTING HARDWARE FOR ALL AIR DEVICES. MECHANICAL
CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL MOUNTING DETAILS AND
REQUIREMENTS WITH CEILING CONTRACTOR.
15. COORDINATE EXACT LOCATIONS OF DIFFUSERS/DUCTWORK WITH LIGHTS, SPRINKLERS,
AND CEILING WITH REFLECTED CEILING PLAN AND ARCHITECT.
16. ALL DIMENSIONS AND PIPE SIZES ARE IN INCHES UNLESS NOTED OTHERWISE.
17. INSTALL DUCTWORK IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION
STANDARDS. PRESSURE CLASSIFICATION OF DUCTWORK TO BE AS FOLLOWS:
• CAV SUPPLY = 1"
• FPU/VAV SUPPLY = 1" DOWNSTREAM OF BOX
• RETURN = 1"
• EXHAUST = 1"
GENERAL NOTES:
18. FOR ALL BRANCH DUCT CONNECTIONS TO MAIN TRUNK, PROVIDE 45 DEGREE…