4-2026 Storm Drain Projects Bid Set.pdf
PDF 21 MB Posted
- Attached to
- 2026 Storm Drain Projects State and local contract opportunity
- Solicitation number
- Not on record
- Issued by
- Utah
About this file
This is a design bid set document for the City of Bountiful, Utah Engineering Department's 2026 Storm Drain Projects. The document comprises detailed construction plans and specifications for three storm drain infrastructure projects scheduled for completion by June 30, 2026. The bid set includes plan views with 1" = 40' and 1" = 30' scales, showing project locations at Chelsea Drive/400 East, Davis Boulevard/400 East, and Bonneview Drive/2150 South. Work involves slip lining existing 24-inch pipe with 15-inch HDPE storm pipe, abandoning existing storm drain pipes, connecting to existing infrastructure, and removing 87 linear feet of existing pipe. The plans indicate coordination requirements with the Weber Basin Water Conservancy District for permitting related to the 48-inch Davis Aqueduct. The document is designated as a sealed bid set not for construction, containing eight sheets including title sheet, project sheets, and detailed specifications across multiple sheets.
The design documents establish baseline technical requirements for bidders preparing sealed bids due April 21, 2026, at 2:00 p.m. at the City Engineer's office located at 795 South Main Street, Bountiful, Utah 84010. Bidders are required to provide five percent bid security and must familiarize themselves with site conditions through the technical plans provided. The City of Bountiful will make award decisions within seven days after bids are opened, with successful contractors required to furnish performance and payment bonds equal to 100 percent of contract price and maintain specified insurance coverage. No set-asides for disadvantaged or small businesses have been designated. The projects are not federally funded and do not require prevailing wage compliance. All contractors must obtain proper licensing from the Utah State Department of Commerce, Division of Occupational and Professional Licensing, with all subcontractors similarly licensed.
View the file
Other files for this state and local contract opportunity
Show all 39
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
s d s d s d s d s d s d s d s d s d s d s d s d s d
B Y
D E
S C
R
IP
TI
O
N D
A
TE
N o.
REVISIONS
SHEET
7OF
S ou th M ai n
St re et B ou nt ifu l, U ta h
1)
8-
B O
U N
TI
FU
L, U
TA
H
B O
U N
TI
FU
L C
IT
Y
E N
G
IN
E E
R
IN
G D
E P
A R
TM
E
N T
D E
S
IG
N
S
TO
R M
D R
A
IN
P R
O
JE
C
TS
D R
A W
N C
H E
C K
D A
TE
B
O O
K
1" = 40'
SCALE
FO
LD
E R
P
O C
K E
T
SEAL
BID SET
NOT FOR
CONSTRUCTION
P
LA
N V
IE
W
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 420 E
AutoCAD SHX Text 421 E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 420 E
AutoCAD SHX Text 421 E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 40'
AutoCAD SHX Text 80'
AutoCAD SHX Text
EST. 1847
AutoCAD SHX Text
BCC
AutoCAD SHX Text 6/30/2026
AutoCAD SHX Text CONNECT EXISTING. SLIP LINE EXISTING 24-INCH PIPE WITH 5' OF 15-INCH HDPE STORM PIPE. GROUT 3" ANNULAR SPACE. SEE DETAIL
AutoCAD SHX Text
ABANDON EXISTING PIPE
AutoCAD SHX Text
CONNECT TO EXISTING PIPE
AutoCAD SHX Text
CONNECT TO EXISTING PIPE
AutoCAD SHX Text 400 East
AutoCAD SHX Text
CHELSEA DR
s d s d s d s d s d s d s d s d s d s d
B Y
D E
S C
R
IP
TI
O
N D
A
TE
N o.
REVISIONS
SHEET
7OF
S ou th M ai n
St re et B ou nt ifu l, U ta h
1)
8-
B O
U N
TI
FU
L, U
TA
H
B O
U N
TI
FU
L C
IT
Y
E N
G
IN
E E
R
IN
G D
E P
A R
TM
E
N T
D E
S
IG
N
S
TO
R M
D R
A
IN
P R
O
JE
C
TS
D R
A W
N C
H E
C K
D A
TE
B
O O
K
1" = 30'
SCALE
FO
LD
E R
P
O C
K E
T
SEAL
BID SET
NOT FOR
CONSTRUCTION
P
LA
N V
IE
W
AutoCAD SHX Text 2375 S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2375 S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 30'
AutoCAD SHX Text 60'
AutoCAD SHX Text
EST. 1847
AutoCAD SHX Text
BCC
AutoCAD SHX Text 6/30/2026
AutoCAD SHX Text
DAVIS BLVD
AutoCAD SHX Text 400 E
AutoCAD SHX Text 48" DAVIS AQUEDUCT - CONTACT WEBER BASIN WATER CONSERVANCY DISTRICT FOR PERMITTING REQUIREMENTS
AutoCAD SHX Text
ABANDON EXISTING SD PIPE
CONNECT TO EXISTING PIPE
s d s d s d s d s d s d s d s d s d s d s d s d s d
B Y
D E
S C
R
IP
TI
O
N D
A
TE
N o.
REVISIONS
SHEET
7OF
S ou th M ai n
St re et B ou nt ifu l, U ta h
1)
8-
B O
U N
TI
FU
L, U
TA
H
B O
U N
TI
FU
L C
IT
Y
E N
G
IN
E E
R
IN
G D
E P
A R
TM
E
N T
D E
S
IG
N
S
TO
R M
D R
A
IN
P R
O
JE
C
TS
D R
A W
N C
H E
C K
D A
TE
B
O O
K
1" = 30'
SCALE
FO
LD
E R
P
O C
K E
T
SEAL
BID SET
NOT FOR
CONSTRUCTION
P
LA
N V
IE
W
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 30'
AutoCAD SHX Text 60'
AutoCAD SHX Text
EST. 1847
AutoCAD SHX Text
BCC
AutoCAD SHX Text 6/30/2026
AutoCAD SHX Text 2050 S
AutoCAD SHX Text
BONNEVIEW DR
AutoCAD SHX Text 2150 S
REMOVE 87 LF EXISTING PIPE
| SHEET 1_TITLE |
| SHEET 2 THROUGH 4_PP |
| 2026 SD Projects_Extra-Sheet - (7) |
| 2026 SD Projects_Extra-Sheet - (8) |
| 2026 SD Projects_Extra-Sheet - (9) |
| SHEET 5_DRY CREEK |
| SHEET 6_DETAILS |
| SHEET 7_DETAILS |
| SHEET 8_DETAILS |
File details come from the government source that posted it. Updated .