3826_PUMP_SPECIFICATIONS.pdf
PDF 10 MB Posted
- Attached to
- Splashpad Renovation and Improvement
- Solicitation number
- 38-26
- Issued by
- Florida
About this file
This document is a collection of technical specifications and product documentation related to a splashpad renovation and improvement project in Florida. The file includes detailed specifications for multiple types of equipment and components that would be utilized in such a facility, including pitot tube insertion flow meters from Blue-White Industries (models F-300, D-300, and U-300 series with pipe sizes ranging from 1" to 8" and flow rates from 4 to 1900 GPM), pool skimming equipment (No-Niche skimmers constructed from ABS plastic with flow rates of 52-55 GPM), variable frequency drives (Yaskawa GA500 AC drives with power ratings from 1/6 to 40 HP across multiple voltage configurations), fiberglass side-mount media filters (Waterco HRVR series with models 24, 30, and 36 featuring maximum operating pressures of 58 PSI), metering pumps (Stenner 45 and 85 series adjustable output pumps with maximum pressures of 100 psi and adjustable outputs ranging from 0.2 to 85 GPM), multiport valves (Waterco models rated at 58 PSI with flow rates up to 310 GPM), pressure gauges (glycerine-filled stainless steel gauges with various dial sizes), and thermometers (bimetal hot water thermometers for hydronic systems).
The documentation provides comprehensive technical data including materials of construction, installation requirements, dimensional specifications, flow rates, pressure ratings, accuracy tolerances, and operational parameters for each component. These specifications establish the technical requirements and performance standards that qualified contractors must meet when renovating and improving the splashpad facility. The materials suggest a comprehensive water circulation, filtration, and monitoring system suitable for a public recreational splash facility, with equipment selections emphasizing durability, NSF compliance where applicable, and reliable performance under continuous operational conditions.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3826_STAMPED_PLAN_SET_91626.pdf | ||
| 3826_COMPILED_SPECIFICATIONS.pdf | ||
| RFP_3826__Splashpad_Renovation_and_Improvement.pdf | ||
| 3826_FIXTURE_SPECIFICATIONS.pdf | ||
| Exhibit_I_Bid_Price_Sheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Features:
! 1” through 8” pipe sizes.
! Flow rates from 4 to 1900 GPM.
! Resistant PVDF internal float materials.
! One piece machined acrylic body.
Blue-White Industries, Ltd.
Pitot Tube Insertion Meters
Specifications:
Materials of Construction:
R
Installation Requirements:
Minimum Straight Pipe Length Requirements
The meter’s accuracy is affected by disturbances such as pumps, elbows, tees, valves, etc., in the flow stream. Install the meter in a straight run of pipe as far as possible from any disturbances.
Mounting location ! The meter is designed to withstand outdoor conditions.
! F series meters must be mounted at the vertical (twelve o'clock) position on horizontal pipe only.
! U & D series meters must be mounted on vertical pipe only.
! The pipe must be completely full of water at all times.
! See the minimum straight length of pipe requirement chart above.
! The meter can accurately measure flow from one direction only.
! U-series meters measure upward flows only.
! D-series meters measure downward flows only.
Engineering and Technical Data
MINIMUM
INPUT
LENGTH
MINIMUM
OUTPUT
LENGTH
I.D.FLOW
Horizontal Mount
FLOW
No Vertical Mount
MINIMUM
INPUT
LENGTH
MINIMUM
OUTPUT
LENGTH
I.D
F
LO
W
F L
O W
Clamp-on Insertion Mount
F-300
D-300 U-300
F-300 SERIES
MINIMUM
INPUT
LENGTH
MINIMUM
OUTPUT
LENGTH
I.D.FLOW
No Horizontal Mount
U-300 & D-300 SERIES
MINIMUM
INPUT
LENGTH
MINIMUM
OUTPUT
LENGTH
I.D
F
LO
W
Vertical Mount
! Mounts to existing pipe. No unions or adapters required.
! Models for mounting on horizontal or vertical pipe.
! Mounting clamps and gasket included.
! NSF Listed
Pipe Requirements IPS inch pipe size (ASTM-D-1785)
Max PSI (bar) 75 PSI (5.2 bar) at 70˚F (21˚C)
Fluid Temp Range 0˚ to 190˚F / -18 to 88˚C @ 0 PSI
Ambient Temp Range 0˚ TO 110˚F / -18 TO 43˚C
Note: Temperature and Pressure ratings for meter only. Actual pipe rating may vary.
Accuracy 1”, 1.25”, 1.5” and 2” pipe size: 5% of rate
2.5”, 3”, 4”, 6”, and 8” pipe size: 10% of rate
Power Requirement No Power Required
Enclosure NEMA 4X (IP56)
Approximate Ship Wt 1” - 4” units: 1lb (.45kg)
6” - 8” units: 2lb (.91kg)
Meter Body Cast Acrylic Gasket Neoprene
Float PVDF Pipe Clamp 316 Series Stainless Steel
EXAMPLE OF MINIMUM STRAIGHT PIPE LENGTH
Nominal Pipe Diameter Minimum Inlet Pipe Length Minimum Outlet Pipe Length
4 inch 20 inch (5” x 4”) 8 inch (2” x 4”)
6 inch 30 inch (5” x 6”) 12 inch (2” x 6”)
F-300D-300
Blue-White Industries, Ltd.
Dimensions:
Pipe Size, Flow Range and Display Model Options:
Blue-White Industries, Ltd.
R 5300 Business Drive, Huntington Beach, CA 92649 Tel: 714-893-8529 Fax: 714-894-9492 www.blue-white.com Email: sales@blue-white.com Technical data sheet #85000-071 rev.31 20200707
All trademarks are the property of their respective owners.
R
Flow Stream Requirements:
Low viscosity fluids with a specific gravity of 1.0.
Model Number Matrix:
Meter Series 30 = 300 series meter
- 600 PF
Maximum Temperature vs. Pressure
0 30(2.1) 60(4.1) 90(6.2) 120(8.3) 150(10.3)
STATIC PRESSURE PSI (BAR)
o o 70 F (21 C) o o94 F (34 C) o o 118 F (48 C) o o 142 F (61 C) o o 190 F (88 C)
T E
M P
E R
A T
U R
E o o166 F (74 C)
Pipe Size
100 = 1”
125 = 1-1/4”
150 = 1-1/2”
200 = 2”
250 = 2-1/2”
300 = 3”
400 = 4”
600 = 6”
800 = 8”
Pipe Size, type and saddle material
P = Sch 40 or 80 IPS Pipe (ASTM-D-1785)
U/D-300 Series
A
6”
6”
Pipe Size
1-1/2”
2”
A
B
B
1-9/16”
1-9/16”
FLOW
A
B
Meter Series
F = Horizontal Pipe Mount
U = Vertical Pipe with Upward Flow
D = Vertical Pipe with Downward Flow
Models for Mounting on Vertical Pipe Models for U.S. IPS Sch40 & 80 Pipe (ASTM 1785)
Display in U.S. Gallons per Minute
Pitot Tube Insertion Meters
Models for Mounting on Horizontal Pipe Models for U.S. IPS Sch40 & 80 Pipe (ASTM 1785)
Display in U.S. Gallons per Minute
Note: see available models below.
F-300 Series
Pipe Size A B
1” 6” 2-7/16”
1-1/4” 6” 2-7/16”
1-1/2” 6” 2-7/16”
2” 6” 2-7/16”
2-1/2” 6” 2-7/16”
3” 6” 2-7/16”
4” 6” 2-7/16”
6” 7-1/2” 2-7/16”
8” 7-1/2” 2-7/16”
Pipe Size Sch40 Sch80 Model Number
1” 5 to 35 4 to 26 F-30100P
1-1/4” 9 to 50 8 to 40 F-30125P
1-1/2” 10 to 70 10 to 60 F-30150P
2” 20 to 120 18 to 100 F-30200P
2-1/2” 29 to 150 25 to 130 F-30250P
3” 45 to 240 40 to 215 F-30300P
4” 75 to 420 70 to 400 F-30400P
6” 170 to 1100 160 to 1000 F-30600P
8” 300 to 2200 275 to 1950 F-30800P
Pipe Size Sch40 Sch80 Flow Direction Model Number
1-1/2” 10 to 60 10 to 50 UP U-30150P
1-1/2” 10 to 60 10 to 50 DOWN D-30150P
2” 20 to 110 20 to 100 UP U-30200P
2” 20 to 110 20 to 100 DOWN D-30200P
28 Quality Pool & Spa Replacement Parts Since 1950
EQUIPMENT COMPANY, INC.
No-Niche® Skimmer
The Skimmer That Operates Without A Niche
No-niche® is no ordinary skimmer. It replaces the need for a niche - the weakest point in a pools construction. Construct-ing a niche can substantially increase the cost of a pool.
Operating in a confined niche, conventional skimmers often don’t do an adequate job of keeping a pool clean. The No-niche® has a flow rate of 52-55 gallons per minute.
No-niche® is efficient. With 360° skimmer actions, No-niche® has sufficient skimming power to allow opening of the main drain. Water filters faster, keeping the pool cleaner. No-niche® works on a floatation system that automatically adjusts to average water level changes.
No-niche® is compact. It does a big job while remaining unobstructive and almost invisable. No-niche® utilizes an exceptionaly large skimmer basket considering it’s compact size to filter more debris without clogging. It can be used in new pool construction, with existing VAC outlets, or in place of an inefficient skimmer.
No-niche® is constructed from ABS plastic for strength and durability. It comes complete with a vacuum fitting (No. 752). With the basket and float removed, the hose fitting attaches to the hose and the bottom of the skimmer without threading.
NOTE: AMERICAN VAC PLATE WORKS ON
No-niche®. (No. 920)
| No. 750 | Complete Assembly |
| No. 751 | Top and Main Housing |
| No. 752 | Vacuum Fitting |
No. B-13 Basket Only No. B-38 Skimmer Weir
Also available in Black ABS for KOI ponds. (No. 750B)
No.750
GA500
A C M I C R O D R I V E F O R I N D U S T R I A L A P P L I C A T I O N S
T I M E & C O S T S AV I N G S
| • | Operates any motor on any network |
| • | DriveWorksEZ® improves customization by |
eliminating a PLC and simplified wiring
| • | Integrated braking transistor |
| • | Integrated EMC filter (optional) |
| • | Integrated 24 VDC power supply supports use of |
external sensors without extra power supply
E A S Y T O U S E & M A I N TA I N
• Reduce setup time with an intuitive keypad and setup wizards
| • | Simple parameter structure |
| • | Maintain network communications during loss |
of main input power
• Access to main circuit w/o removing cover
E A S Y M A C H I N E D E S I G N
| • | Wide power and voltage range |
| • | Coated PCBs for use in harsh environments |
| • | Speed search |
| • | Stall prevention and torque limit |
| • | Meets global standards (UL, cUL, CE, TUV, RCM) |
| • | Supports all major networks |
E A S Y I N S TA L L AT I O N &
S Y S T E M I N T E G R AT I O N
| • | Embedded functional safety (STO: SIL3, PLe) |
| • | Embedded Modbus RTU |
| • | Up to 5 drives with 1 network option card |
| • | Side-by-side mounting |
| • | Bottom cable entries, cage clamp terminals |
| • | DIN rail mounting adapter |
| • | DriveWizard® Mobile app for easy and |
convenient setup
• Optional LCD operator
This microdrive is engineered to help you easily handle nearly any application. Sustainability, flexibility and ease of use are all designed into the drive, helping you make complicated tasks simple.
Offering intuitive interaction and world-class quality, the GA500 is the drive you can count on for constant, high quality performance.
Make your day easier and leave more time for other tasks by trusting the GA500 from Yaskawa.
quality sustainable powerful easy integration
COMPLICATED
SIMPLE
effortless flexible intuitivesafe rugged
240 VAC, Single-Phase: 1/6 – 5 HP 240 VAC, Three-Phase: 1/6 – 30 HP 480 VAC, Three-Phase: 1/2 – 40 HP
G A 5 0 0 A C D R I V E
EASILY HANDLE
ANY APPLICATION.
MAKING
2 3
QUICK AND EASY SOLID HARDWARE
Reduce setup time to minutes using the setup wizard.
Even without any drive parameter knowledge, the step-by-step wizard will guide you and get you up and running.
Whether you are installing, wiring, programming, or troubleshooting, the GA500 has features that help simplify the task for you.
SUSTAINABLE FLEXIBLE
EASY
N O P O W E R ? N O P R O B L E M !
The GA500 can be programmed without any power supply connected, even while the drive is still in the box. Simply plug into one of your PC’s USB ports or any USB on-the-go device, start programming and enjoy the ease of commissioning.
Enhance your experience with the optional LCD keypad.
Bluetooth® is a registered trademark of Bluetooth SIG, Inc. USA.
O P T I O N A L L C D K E Y P A D
Advanced keypad navigation:
| • | High-resolution display |
| • | Automatic backup function |
| • | Copy function (4 parameter sets) |
| • | Real-time clock |
| • | Micro SD storage for data logging |
(up to 32 GB)
• Optional Bluetooth® version
Power Range
| • | 240 VAC, Single-Phase: 1/6 – 5 HP |
| • | 240 VAC, Three-Phase: 1/6 – 30 HP |
| • | 480 VAC, Three-Phase: 1/2 – 40 HP |
Display Easy-to-read LED display.
Keypad Multi-directional buttons to help you intuitively navigate through drive menus and parameters.
Tactile feel of the buttons lets you know when you’ve pressed a button.
USB Port Easily connect your PC or mobile device to program the drive with or without power.
LED Status Ring You can determine the drive status with a quick glance at the LED status ring and know the GA500 is ready and operating.
Finger Safe Terminals Easily access terminals to make the wiring process faster and easier. No need to remove the cover.
Parameter Backup / Copy Removable keypad allows you to back up and copy parameters to other drives.
24 VDC Power Input for Controller Simplify your wiring and keep your control system operating even during standby or power outage.
4 5
E F F O R T L E S S
NETWORK INTEGRATION
Connect to your network in less than 60 seconds.
GA500 drives support all the major industrial communications and connection topologies (ring, star, line, etc.) to adapt to various factory automation networks. Reduce wiring when connecting to an upper level controller or PLC through available built-in protocols or dedicated communication options.
C O S T E F F E C T I V E
I N T E G R AT I O N
Reduce the number of option cards up to 80%. Only a single communication option card is required to network up to 5 drives via the RS-485 terminals.
E M B E D D E D + 2 4 V D C I N P U T A C C E S S
Network communication can be maintained during loss of main input power utilizing the +24 VDC input. An external +24 VDC supply also allows you the ability to program the drive without main power.
C O N F I G U R AT I O N S
PLC or Controller
RS-485
One option Card to Network Five Drives
LI
N
E
ST
A R
R
IN
G
SUSTAINABLE FLEXIBLE
EASY
ONE FOR ALL
The GA500 precisely controls induction, permanent magnet, and synchronous reluctance motors providing versatility to run a variety of applications with just one drive.
O N E D R I V E
F O R VA R I O U S
A P P L I C AT I O N S
• 590 Hz output frequency (optional: up to 2000 Hz)
• Open loop zero speed and torque control of permanent magnet motors
E N E R G Y S AV I N G S
• Automatic energy efficiency optimizer with GA500 energy saving functions
A U T O M AT I C
E N E R G Y E F F I C I E N C Y O P T I M I Z E R
Energy usage is automatically optimized with the unique energy savings functions of the GA500.
These functions minimize energy consumption through varying load and speed ranges, achieving power optimization for energy cost reduction. Maximize your energy usage by optimizing your motor torque per amp.
Smart Power Saver
Ef fic ie nc y
Speed [%] 200 40 60 80 100
GA500
CONVENTIONAL DRIVE
6% INCREASE FOR INDUCTION
MOTORS AT 20% SPEED
2% IMPROVEMENT FOR PM MOTORS
Speed (%)
E ffi c ie n c y
Smart Power Saver
GA500
CONVENTIONAL DRIVE
Typical Operating Range
With Permanent
Magnet Motor
Up to 2% More Savings
With Induction Motor
Up to 6% More Savings
Motor Control Benefits/Features:
INDUCTION
MOTORS
INTERIOR
PERMANENT
MAGNET
SURFACE
PERMANENT
MAGNET
SYNCHRONOUS
RELUCTANCE
6 7
I N T E G R AT E D F U C T I O N A L S A F E T Y
PLAY IT SAFE
With the built-in dual channel STO (safe torque off, SIL3/PLe), the GA500 provides the right tools for easy machine integration of emergency stop functions, even when elevated levels of risk reduction are required.
RUGGED
C O AT E D C I R C U I T B O A R D
P R O T E C T I O N
Coated PCBs as standard protect the electronics from dust or humidity, while ensuring reliable operation even in harsh environments (IEC 60723-3-3, 3C2, 3S2).
W I D E A M B I E N T
T E M P E R AT U R E R A N G E
GA500 drives can be safely operated in ambient temperatures ranging from -10°C up to 60°C. In environments with conditions up to 50°C, no derating is necessary.
Designed for 10 years of maintenance-free operation, the GA500 is built tough to withstand harsh and demanding conditions.
TÜV Certified
Functional Safety
V t
STO
V t
STO
t1
SS1
V t
SOSt1
SS2
P o si ti o n t
SOS
V t
Safe Speed Window
SLS
t
Safe Torque Range
T o rq ue
SLT *
T em p er at ur e t
Safe Temperature Window
SMT *
P o si ti o n t
Safe Position Monitor
Safe Output Status
SCA *
t
Safe Speed Window
V
SSR *
t
Safe Direction
V
SDI *
P o si ti o n t
Safe Position Window
SLP *SLA *
t
Acceleration limit
V
T o rq ue
SLI *
P o si ti o n t
SOS SLP
SOS SLP
SSM *
S p ee d t
Safe Speed Monitor
Safe Output Status
FSoE (FailSafe over
EtherCAT)
SUSTAINABLE FLEXIBLE
EASY
FLEXIBLE INSTALLATION
SOLUTIONS
The flexible package design of the GA500 enables reliable operation under a variety of environmental conditions. Regardless of whether you put the drive in a control cabinet, on a wall, in a clean environment, or in a harsh one.
CONVENTIONAL
DRIVE
CONVENTIONAL
DRIVE
CONVENTIONAL
DRIVE
CONVENTIONAL
DRIVE
B U I L T - I N E M C F I L T E R
The GA500 is available both with and without an embedded EMC filter.
E A S Y E X T E R N A L
H E AT S I N K M O U N T I N G
With an optional ring kit, the GA500 offers easy installation for mounting the heatsink outside the cabinet to reduce cabinet size and cooling requirements.
S I D E - B Y - S I D E M O U N T I N G
The GA500 can be mounted side-by-side with bottom entry wiring to reduce cabinet size.
Without EMC Filter
Built-in EMC Filter
Reduced Cabinet
Size
D I N R A I L M O U N T I N G
GA500 drives up to
7.5 HP can be simply
snapped onto a DIN rail using an optional attachment. This saves valuable time during installation.
U L T Y P E 1 K I T For installations that require UL Type 1, the GA500 can be simply converted with a mechanical kit.
UL Type 1 Kit
Up to 45%
8 9
SOFTWARE TOOLS
P O W E R F U L
If you are looking to keep a backup copy of your GA500’s parameter set or need to customize the drive’s functionality to match your application, the GA500 has the software tools to help.
D R I V E W I Z A R D ® M O B I L E A P P
The DriveWizard® Mobile app turns your smartphone or tablet into an interface for your GA500 drive. All information for parameter setup and troubleshooting are in your pocket – anytime, anywhere. Scanning the drive QR code provides easy access to drive information and status. DriveWizard Mobile also provides:
• Intuitive parameter editing with help and search function
| • | Custom parameter and monitor lists |
| • | Parameter backup/verify with or without |
main power applied to the drive
| • | Yaskawa Drive Cloud™ Service |
| • | Export to DriveWizard® Industrial |
SUSTAINABLE FLEXIBLE
EASY
D R I V E W I Z A R D ® I N D U S T R I A L
| • | Manage your parameters online or offline |
| • | Create configurations offline, then later connect and |
download them to the GA500
• Connect via USB, and interface with the GA500 even without main power
| • | Monitor using a dashboard of dynamic variables |
| • | Create reports for exporting and emailing |
D R I V E W O R K S E Z ®
• Create simple, custom logic and eliminate an external controller
| • | Drag-n-drop graphical interface |
| • | 400+ function blocks |
| • | Up to 100 connections |
| • | Offline simulation mode for testing without |
the risk of an application malfunction
• Protection of intellectual property with locked projectsDriveWizard® and DriveWorksEZ® are registered trademarks of Yaskawa America, Inc.
P A R A M E T E R C O M P AT I B I L I T Y
DriveWizard® makes it simple to transition from previous generation drives to the GA500.
YA S K AWA M A N U A L S A P P
You will have all drive information available, without carrying heavy manuals.
| • | Resize text for improved readability |
| • | Search feature to find the information you need |
| • | �Access to the most up-to-date technical information |
(when connected online)
• �Download manuals for use when an online connection isn't available
YA S K AWA D R I V E
C L O U D ™ S E R V I C E
| • | Product registration with QR code |
| • | Complimentary storage for parameter |
backups, relevant files, and notes
• Accessible anywhere
YA S K AWA D R I V E C L O U D ™
The Yaskawa Drive Cloud service provides an easy and safe way to keep track of all of your drive data.
Transition to
GA500!
10 11
F A N
Control air flow and save energy by being able to easily control the speed of your fan.
M I X E R
High torque to be able to mix any type of material, precise speed control to make sure that it gets done right.
P U M P
Maintain constant water pressure with the PID functionality of a drive.
M A C H I N I N G C E N T E R
Power and precision to create the parts that you need.
From the moment you wake in the morning to the moment your head hits the pillow at night, you have a lot going on in your mind.
At Yaskawa, we consider it our job to provide you the highest quality, most reliable variable frequency drive product and service – so every day in your life can be just a little bit easier.
SUSTAINABLE FLEXIBLE
EASY
C O N V E Y O R
Reduce mechanical stress on your machine by gently ramping up to speed.
MAKING YOUR
DAY EASIER
We make the complicated
SIMPLE!
12 13
Catalog Code Designation
Environmental Specifications
A: Standard
GA50 U 4 004 A B A
Voltage Class
B: 240 V Single-phase
2: 240 V Three-phase
4: 480 V Three-phase
Product Series
GA500 Series
Rated Output Current
See Ratings Table
EMC Filter Option
A: No built-in filter
E: Built-in EMC filter
Enclosure B: IP20/Protected Chassis
Region Code
U: Americas
Power Output
(HP)
240 V Models 480 V Models
Single-Phase Three-Phase Three-Phase
Normal Duty
(ND)
Heavy Duty
(HD)
Catalog Code Output Amps
Fr a m e
Catalog Code Output Amps
Fr a m e
Catalog Code Output Amps
Fr a m e
ND HD ND HD ND HD
1/6 1/6 GA50UB001ABA 1.2 0.8 1.1 GA50U2001ABA 1.2 0.8 1.1
1/4 1/4 GA50UB002ABA 1.9 1.6 1.1 GA50U2002ABA 1.9 1.6 1.1
1/2 1/2 GA50U4001ABA 1.2 1.2 2.1
3/4 1/2 GA50UB004ABA 3.5 3 1.3 GA50U2004ABA 3.5 3 1.2
1 3/4 GA50U4002ABA 2.1 1.8 2.2
1.5 1 GA50UB006ABA 6 5 2.4 GA50U2006ABA 6 5 1.4
2 2 GA50U4004ABA 4.1 3.4 2.4
3 2 GA50UB010ABA 9.6 8 2.5 GA50U2010ABA 9.6 8 2.3
3 3 GA50UB012ABA 12.2 11 3.2 GA50U4005ABA 5.4 4.8 2.5
4 3 GA50U2012ABA 12.2 11 2.4 GA50U4007ABA 7.1 5.6 2.5
5 4 GA50U4009ABA 8.9 7.3 2.5
N/A 5 GA50UB018ABA N/A 17.6 4
7.5 5 GA50U2021ABA 21 17.6 3.1 GA50U4012ABA 11.9 9.2 3.1
10 7.5 GA50U2030ABA 30 25 5
10 10 GA50U4018ABA 17.5 14.8 5
15 10 GA50U2042ABA 42 33 5 GA50U4023ABA 23.4 18 5
20 15 GA50U2056ABA 56 47 6 GA50U4031ABA 31 24 6
25 20 GA50U2070ABA 70 60 7 GA50U4038ABA 38 31 6
30 25 GA50U2082ABA 82 75 7 GA50U4044ABA 44 39 8
40 30 GA50U4060ABA 60 45 8
R AT I N G S
S P E C I F I C AT I O N S
A P P R O X I M AT E D I M E N S I O N S
Frame Size
1.1 1.2 1.3 1.4 2.1 2.2 2.3 2.4 2.5 3.1 3.2 4 5 6 7 8
Height 5.04 (128)
10.24 (260)
11.81 (300)
13.78 (350)
Width 2.68 (68)
4.25 (108)
5.51 (140)
6.69 (170)
5.51 (140)
7.09 (180)
8.66 (220)
7.48 (190)
Depth 2.99 (76)
4.25 (108)
4.65 (118)
5.04 (128)
3.19 (81)
3.90 (99)
5.08 (129)
5.41 (137)
6.06 (154)
5.63 (143)
6.42 (163)
7.09 (180)
5.51 (140)
5.63 (143)
7.36 (187)
8.03 (204)
Dimensions shown in inches (mm).
Information on this page represents IP20/Protected Chassis type enclosures without the built-in EMC filter.
For other enclosure types and enclosure adapters, please visit yaskawa.com.
Operating Environment
Ambient Temperature -10 to +50°C (IP20/Protected Chassis), -10 to +40°C (IP20/UL Type 1), up to +60°C with derating
Storage Temperature -40 to +70°C (short-term temperature during transportation)
Humidity 95% RH or less (non-condensing)
Altitude Up to 1000 m without derating, up to 4000 m with derating
Shock 10 to 20 Hz: 9.8 m/s2
20 to 55 Hz: 5.9 m/s2
Protection Design IP20/Protected Chassis (Standard), IP20/UL Type 1 kit (Optional)
Mounting Side-by-side, DIN rail, external heatsink
Conformal Coating (PCBs) IEC 60721-3-3, Class 3C2 (chemical gases), Class 3S2 (solid particles)
Standards CE, UL, cUL, KC, RCM, EAC, RoHS
Functional Safety IEC/EN 61800-5-2: STO, IEC/EN 61508: SIL3, EN ISO 13849-1: PLe
Power Ratings
Overload Capacity 110%/1 min. (Normal Duty) or 150%/1 min. (Heavy Duty)
Rated Voltage 200 to 240 V, -15 to +10%
380 to 480 V, -15 to +10%
Capacity Range
240 V, Single-phase: 1/6 to 5 HP (0.1 to 3.7 kW)
240 V, Three-Phase: 1/6 to 30 HP (0.1 to 22 kW)
480 V, Three-Phase: 1/4 to 40 HP (0.2 to 30 kW)
Input Frequency 50/60 Hz, +/-5%
Output Voltage Accuracy +/-5%
Output Frequency 0 to 590 Hz (special software for up to 1000 Hz)
Control Method V/f, Open Loop (IM/PM), Advanced Open Loop (PM), EZ Open Loop Vector
Motor Control Induction Motor (IM), Interior or Surface Permanent Magnet Motor (IPM/SPM), Synchronous Reluctance Motor (SynRM)
Standard I/O
(7) multi-function digital inputs (24 VDC)
(2) multi-function analog inputs (0 +/-10 VDC, 4-20 mA)
(1) multi-function pulse input
(2) Safe Torque Off (STO) inputs
(1) fault relay output (form C)
(2) multi-function photocoupler outputs
(1) multi-function analog output (0 - 10 VDC, 4-20 mA)
(1) multi-function pulse output
(1) RS-485 (Modbus RTU)
Additional Functions
Integrated PID controller with sleep function, automatic load distribution for multiple axes (droop control), automatic main power loss ride through, speed search function for smooth start of coasting motors, braking with over-magnetization for fast stop without braking resistors, energy-saving function, automatic restart after failure, overvoltage suppression, virtual input/output custom configuration, application presets, vibration suppression
Options
Communications (Requires Additional Mounting Kit)
CANopen®, CC-Link, DeviceNet™, EtherCAT®, Ethernet/IP™, Ethernet/IP Dual Port, MECHATROLINK-II, MECHATROLINK-III, Modbus/TCP, Modbus/TCP dual port, PROFIBUS-DP®, PROFINET®, LONWORKS
Additional Options Bluetooth keypad, LCD keypad, Attachment for external heatsink, External EMC filters, AC reactors, DC chokes, Network communications adapter, LCD keypad attachment, braking resistors
To learn more about the GA500 and see how it can make your day-to-day life easier, please visit https://www.yaskawa.com/ga500.
SPECIFICATIONS
SUSTAINABLE FLEXIBLE
EASY
14 15
Yaskawa America, Inc. | Drives & Motion Division
1-800-YASKAWA | Email: info@yaskawa.com | yaskawa.com
Document No. BL.GA500.01 | 04/08/2021 | © 2021 Yaskawa America, Inc.
Yaskawa is the leading global manufacturer of low and medium voltage variable frequency drives, servo systems, machine controllers and industrial robots. Our standard products, as well as tailor-made solutions, are well known and have a high reputation for outstanding quality and reliability.
Y A S K A WA . C O M
CJ
V
VV A I I:. K.'-U
water, the liquid of life www.waterco.us
HRVR SERIES
SIDE MOUNT MEDIA FILTERS
Waterco fiberglass filters embody the latest in fiberglass winding technology. The filters are constructed from anti-corrosive, nontoxic materials and are engineered to withstand the high flow and pressures of today’s demanding installations. With the reinforced neck ring and solid lid closure this filter is the best for today’s most demanding projects. Maximum operating pressure: 58PSI
• Internal Bulkhead Wall reinforced for superior structural integrity
• Retro Fit Design with 7.5" Port Spacing for direct replacement for Pentair's Triton
• Positive 8" clamping design for larger internal access
• 2" Bulkhead Connections
• 1.5 " Drain Assembly
• Fishtail Laterals for improved backwashing hydraulic efficiency
• Saves up to 30% waste water
• Industry Leading 10 Year Tank Warranty
Waterco.us 1.800.247.7291
MultiCyclone > Filters > Pumps > Lights > Media > White Goods > Valves
J
L
Z
B
C
V
T
S H
K
DIMENSIONS
SPECIFICATIONS
VALVES
HRVR SIDE MOUNT SAND FILTER
BEST IN CLASS - FEATURING OUR FISHTAIL LATERAL SYSTEM
• Better Coverage Eliminates Dead Space
• Engineered to Improve Backwash Efficiency
• Reduces Filtration pressure loss
• In combination with Waterco’s Glass Pearls saves up to 30% of backwash water
Dead Space Between Laterals Dead Space Virtually Eliminated
PART NUMBER PRODUCT DESCRIPTION NSF
22207248R HRVR 24 2" BH CONN. 58 PSI (NSF) 7.5" PORT SPACING
22207308R HRVR 30 2" BH CONN. 58 PSI (NSF) 7.5" PORT SPACING
22207368R HRVR 36 2" BH CONN. 58 PSI (NSF) 7.5" PORT SPACING
PART NUMBER PRODUCT DESCRIPTION
2290591 MPV 2" SM NPT WITH PIPING AND HRVR UNION 7.5" PORT
MODEL
PORT
SIZE
BED
DEPTH
INNER
DIAM.
FILTER
AREA
MAX
FLOW
MAX
POOL
SIZE
BACK-
WASH
FLOW
RATE
MEDIA
VOLUME
GLASS
PEARL
0.6-0.8
SAND
0.6-1.2
INCH INCH INCH SQ FT GPM GAL GPM GAL LB LB
HRVR 24 2.0 11.0 24 3.14 63 22,680 47-63 24 360 325
HRVR 30 2.0 12.0 30 4.91 98 35,280 74-98 45 660 600
HRVR 36 2.0 13.0 36 7.07 141 50,760 106-141 64 950 850
MODEL B C H J K L S T V Z
HRVR 24 24.6 37.3 23.1 19.0 4.2 2.5 21.125 13.625 27.8 32.1
HRVR 30 31.1 41.5 23.5 23.0 5.7 4.7 23.750 16.250 29.4 36.3
HRVR 36 36.5 45.5 30.8 24.6 7.4 1.9 26.250 18.750 35.8 40.2
INCHES
2.7.23
A Division of Engineered Specialty Products, Inc. 17
SPECIFICATIONS
AVAILABLE OPTIONS*
APPROXIMATE SHIPPING WEIGHTS/
BOX QUANTITIES
201L LIQUID FILLED
LOWER MOUNT
Glycerine filled for added durability in applications where vibration or pulsation is present Stainless steel case and bezel, copper alloy internals
| Dial | 1 ½” (40 mm), 2” (50 mm), 2 ½” (63 mm), | |
| 4” (100 mm) | ||
| Case | Stainless steel, glycerine filled | |
| Wetted Parts | Copper alloy | |
| Bezel | Stainless steel, fixed | |
| Lens | Polycarbonate | |
| Pointer | Black aluminum | |
| Connection | Lower mount | |
| 1 ½” dial = ⅛” NPT | ||
| 2” dial = ⅛” or ¼” NPT | ||
| 2 ½” dial = ¼” NPT | ||
| 4” dial = ¼” or ½” NPT | ||
| Scale | Standard: psi/BAR (x 100 = kPa) | |
| Single scale psi available from stock | ||
| Accuracy | 3-2-3% of span 1 ½” & 2” ASME B40.1 Grade B | |
| 2-1-2% of span 2 ½” & 4” ASME B40.1 Grade A | ||
| Ambient Temp | Glycerine Filled = 30° F to 160° F | |
| Dry = -30° F to 180° F |
▪ Certificate of Accuracy, NIST traceable
▪ Custom Dial
▪ Liquid Fill Options, see page 176
▪ Anti-Vibration Movement, see page 109
▪ Glass Lens
▪ Dry, Fillable Case
▪ Cleaned for Oxygen Service (dry only)
▪ Special Connection Size
▪ Protective Rubber Cover, see page 121
▪ Max/Min Pointer, see page 122
*Lead times/minimums may apply
Dial Size Est. Unit Weight
Box Qty
1 ½” 0.20 lbs (0.10 kg)
2” 0.40 lbs (0.18 kg)
2 ½” 0.55 lbs (0.24 kg)
4” 1.5 lbs (0.68 kg)
Dial Unit A B C D E
1 ½” In. 1.85” 1.00” 0.67” 2.28”
⅛” NPT
mm 47 25 17 58
2” In. 2.27” 1.20” 0.91” 2.95” ⅛” or ¼”
NPTmm 58 31 23 75
2 ½” In. 2.80” 1.40” 1.07” 3.55”
¼” NPT
mm 71 36 27 90
4” In. 4.29” 1.75” 1.17” 5.21” ¼” or ½”
NPTmm 109 45 30 132
Stainless Steel Case, Copper alloy Internals
Design meets or exceeds ASME B40.100 pressure gauge standard.
CLASSIC - SINGLE HEAD ADJUSTABLE SPECIFICATIONS
10.6"
6.0"
5.3"
SHIPPING WEIGHT 9 lbs (4 kg)
FEATURES
• 3-point roller design assists in anti-siphon protection
• Pump head requires no valves, allows for easy maintenance
• Self-priming against maximum working pressure, foot valve not required
• Pump does not lose prime or vapor lock
• Pumps off-gassing solutions and can run dry
• Output volume is not affected by back pressure
• Injection check valve included with models rated 100 psi (6.9 bar) maximum
• Easy to change pump tube; lubrication is not required
• Pump tubes and pump heads interchange between models
• Models (Santoprene® only) tested by Water Quality Association to conform to ANSI/NSF STD 61
• Adjustable models (Santoprene® only) tested by ETL to conform to ANSI/NSF STD 50
Agency listings vary by model. Contact factory for details.
Jacksonville, Florida USA www.stenner.com © Stenner Pump Company All Rights Reserved
FSPECCSHA 050117This information is not intended for specific application purposes. Stenner Pump Company reserves the right to make changes to prices, products, and specifications at any time without prior notice.
S T E N N E R P U M P C O M PA N Y
Single Head Maximum Pump Tube Gallons Liters Gallons Liters Ounces Milliliters Liters Liters Milliliters Model Pressure Number per Day per Day per Hour per Hour per Minute per Minute per Day per Hour per Minute
45MHP2* 100 psi (6.9 bar) max. #1 0.2 to 3.0 0.8 to 11.4 0.01 to 0.13 0.03 to 0.48 0.02 to 0.27 0.56 to 7.92 0.6 to 9.1 0.03 to 0.38 0.31 to 6.32 45M1 25 psi (1.7 bar) max. #1
45MHP10* 100 psi (6.9 bar) max. #2 0.5 to 10.0 1.9 to 37.9 0.02 to 0.42 0.08 to 1.58 0.04 to 0.89 1.32 to 26.32 1.5 to 30.3 0.06 to 1.26 1.04 to 21.04 45M2 25 psi (1.7 bar) max. #2
45MHP22* 100 psi (6.9 bar) max. #7 1.1 to 22.0 4.2 to 83.3 0.05 to 0.92 0.18 to 3.47 0.10 to 1.96 2.92 to 57.85 3.3 to 66.6 0.14 to 2.78 2.29 to 46.25 45M3 25 psi (1.7 bar) max. #3
45M4 25 psi (1.7 bar) max. #4 1.7 to 35.0 6.4 to 132.5 0.07 to 1.46 0.27 to 5.52 0.15 to 3.11 4.44 to 92.01 5.1 to 106.0 0.21 to 4.42 3.54 to 73.61
45M5 25 psi (1.7 bar) max. #5 2.5 to 50.0 9.5 to 189.3 0.10 to 2.08 0.40 to 7.89 0.22 to 4.44 6.60 to 131.43 7.6 to 151.4 0.32 to 6.31 5.28 to 105.14
Approximate Output @ 60Hz Approximate Output @ 50Hz 45 Series – Adjustable Output Pump
OUTPUT CONTROL
Adjustable models only, external dial ring adjustment from 5%-100% in 2.5% increments
MAXIMUM WORKING PRESSURE
100 psi (6.9 bar) 45MHP2, 45MHP10, 45MHP22, 85MHP5, 85MHP17, 85MHP40
25 psi (1.7 bar) 45M1, 45M2, 45M3, 45M4, 45M5, 85M1, 85M2, 85M3, 85M4, 85M5
MAXIMUM OPERATING TEMPERATURE
125° F (52° C)
MAXIMUM SUCTION LIFT
25 ft (7.6 m) vertical lift, based on water
MOTOR TYPE
1/30 HP, shaded pole, class B
APPROXIMATE GEAR MOTOR RPM
DUTY CYCLE
Continuous
MOTOR VOLTAGE (AMP DRAW)
120V 60Hz 1PH (1.7) 220V 60Hz 1PH (0.9) 230V 50Hz 1PH (0.9) International 250V 50Hz 1PH (0.9) International
POWER CORD TYPE
SJTOW
POWER CORD PLUG END
120V 60Hz NEMA 5/15 220V 60Hz NEMA 6/15 230V 50Hz CEE 7/VII 250V 50Hz CEE 7/VII
MATERIALS OF CONSTRUCTION
All Housings Polycarbonate Pump Tube Santoprene®*, FDA approved or Versilon®**
Check Valve Duckbill Santoprene®*, FDA approved or Pellethane®†
Pump Head Rollers Polyethylene Roller Bushings Oil impregnated bronze Suction/Discharge Tubing, Ferrules Polyethylene, FDA approved Tube and Injection Fittings PVC or Polypropylene, NSF listed Check Valve Fittings Type 1 Rigid PVC, NSF listed Connecting Nuts PVC, NSF Listed 3/8" Adapter PVC or Polypropylene, NSF listed Suction Line Strainer PVC, NSF listed, with ceramic weight All Fasteners Stainless steel Pump Head Latches Polypropylene
ACCESSORY KIT SHIPPED WITH
EACH PUMP
3 connecting nuts 1/4" or 3/8" 3 ferrules 1/4" or 6 mm Europe 1 injection check valve 100 psi (6.9 bar)
OR 1 injection fitting 25 psi (1.7 bar) 1 weighted suction line strainer
1/4", 3/8" or 6 mm Europe 1 20' roll suction/discharge tubing
1/4" or 3/8", white or UV black OR 6 mm white Europe
1 additional pump tube 2 additional latches 1 mounting bracket 1 manual
* Santoprene® is a registered trademark of Exxon Mobil Corporation.
** Versilon® is a registered trademark of Saint-Gobain Performance Plastics.
† Pellethane® is a registered trademark of Lubrizol Advanced Materials, Inc.
CLASSIC - SINGLE HEAD ADJUSTABLE SPECIFICATIONS
*Injection check valve included with pumps rated 100 psi (6.9 bar) maximum.
Single Head Maximum Pump Tube Gallons Liters Gallons Liters Ounces Milliliters Liters Liters Milliliters Model Pressure Number per Day per Day per Hour per Hour per Minute per Minute per Day per Hour per Minute
85MHP5* 100 psi (6.9 bar) max. #1 0.3 to 5.0 1.1 to 18.9 0.01 to 0.21 0.05 to 0.79 0.03 to 0.44 0.76 to 13.13 0.9 to 15.1 0.04 to 0.63 0.52 to 10.49 85M1 25 psi (1.7 bar) max. #1
85MHP17* 100 psi (6.9 bar) max. #2 0.8 to 17.0 3.0 to 64.4 0.03 to 0.71 0.13 to 2.68 0.07 to 1.51 2.08 to 44.65 2.4 to 51.5 0.10 to 2.15 1.67 to 35.76 85M2 25 psi (1.7 bar) max. #2
85MHP40* 100 psi (6.9 bar) max. #7 2.0 to 40.0 7.6 to 151.4 0.08 to 1.67 0.32 to 6.31 0.18 to 3.55 5.27 to 105.14 6.1 to 121.1 0.25 to 5.05 4.24 to 84.10 85M3 25 psi (1.7 bar) max. #3
85M4 25 psi (1.7 bar) max. #4 3.0 to 60.0 11.4 to 227.1 0.13 to 2.50 0.48 to 9.46 0.27 to 5.33 7.92 to 157.71 9.1 to 181.7 0.38 to 7.57 6.32 to 126.18
85M5 25 psi (1.7 bar) max. #5 4.3 to 85.0 16.3 to 321.8 0.18 to 3.54 0.68 to 13.40 0.38 to 7.55 11.32 to 223.40 13.0 to 257.4 0.54 to 10.73 9.03 to 178.75
Approximate Output @ 60Hz Approximate Output @ 50Hz 85 Series – Adjustable Output Pump
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs. The information contained in this flyer is not intended for specific application purposes. Stenner Pump Company reserves the right to make changes to prices, products, and specifications at any time without prior notice.
HOT WATER (HYDRONIC)
BIMETAL THERMOMETERS
Note: not all ranges and stem lengths in stock, please call to check inventory
Designed for and used in the hot water heater and boiler markets this thermometer offers convenient size, cost effective construction and is adaptable with your choice of snap on brass wells (Threaded or Solder Connect).
General Specifications:
2”Dial Size Dual scale 30/240°F and 0/120°C Plastic Lens Black Steel Case w/Chrome Bezel 1 ½”Plain Stem with Spring Clip Slotted adjustment on end of stem 1/2"NPT or Solder Connect Brass Well Accuracy: +/- 1 scale division
B2B1-K Thermometer supplied with ½”NPT Well B2B1-K-SW Thermometer supplied with solder type (sweat) well
Dim, Description IN mm
A Case OD 2.52 64
B Case Depth .42 10.7
C Stem Length 1.66 42
D Stem Diameter .32 8
Threaded Well Solder Well
Dim Inches Millimeters Dim Inches Millimeters
A 1.97 50 A 1.97 50 B .95 24 B .64 16.25 C .86 22 C .78 19.75 D .43 11 D .40 10
E 1/2”NPT E .20 5.15
F .43 11 F .37 9.33
G .275 7 H .075 2 J .865 22
K .43 11 www.waterco.com
Constructed from heavy duty ABS and Glass Filled Polypropylene Waterco Multiport valves are designed for maximum performance and working pressures.
| • | 6-position multiple valve positions |
| • | Top and Side Mount configurations |
| • | Rated at 58 PSI (400kPa) |
Heavy duty construction
VALVES
MULTIPORT
distributed by:
ZZ
B1
4/
OFFICES
Waterco (USA) Inc Augusta, Georgia, USA Tel: +1 706 793 7291
Waterco Canada Longueuil, Quebec, Canada Tel: +1 450 748 1421
OFFICES - OVERSEAS
NSW - Sydney (Head Office) Tel: +61 2 9898 8600
Waterco (Europe) Limited Sittingbourne, Kent. UK Tel: +44 (0) 1795 521 733
Waterco (NZ) Limited Auckland, New Zealand Tel: +64 9 525 7570
Waterco (C) Limited Guangzhou, China Tel: +86 20 3222 2180
Waterco (Far East) Sdn Bhd Selangor, Malaysia Tel: +60 3 6145 6000
PT Waterco Indonesia Jakarta, Indonesia Tel: +62 21 4585 1481
Waterco Singapore Intl Pte Ltd Nehsons Building, Singapore Tel: +65 6344 2378
Waterco France SAINT PRIEST, France.
Tel: +33 4 72 79 33 30
Waterco’s entire range of Multiport valves are engineered to withstand a working pressure of up to 58 psi (400kPa) with a test pressure of 87 psi (600 kPa).
Max flow rate Body Lid Handle Rotor Hardware Union Nut Union Tail
1 1/2” MPV (40mm) 84 ABS ABS ABS GF Noryl SS304 ABS PVC
2” MPV (50mm) 135 ABS ABS ABS GF Noryl SS304 ABS PVC
21/2” MPV (65mm) 206 ABS GFPP ABS GF Noryl SS304 ABS PVC
3” MPV (80mm) 285 GFPP GFPP ABS GF Noryl SS304 ABS PVC
4” MPV (100mm) 310 GFPP GFPP ABS GF Noryl SS304 ABS PVC
MULTIPORT VALVE MAIN FUNCTIONS
| Filter | - | downward flow through the filter bed to outlet |
| Backwash | - | upward flow through the filter bed to waste |
| Rinse | - | downward flow through the filter bed to waste |
| Waste | - | bypass the filter bed to waste |
| Re-circulate | - | bypass the filter bed to outlet |
| Closed | - | no flow to the filter |
Cleansing a filter simply requires shifting the Multiport lever from the “filter” position to the “backwash” position, which reverses the flow of water in the filter, flushing the filter bed.
Warranty
Filter Mode Backwash Mode Rinse Mode
Pressure gauge
Wear resistant rotor
Clear sight glass for backwash inspection.
6 way multiple valve positions
High grade stainless steel components
Durable lever action handle
Metric or imperial quick connect unions
Heavy duty ABS construction
Multi Port Valve 1 Year
Commercial Installation 1 Year
Owner
Owner
| 56596 Old City Hall IWF Rev.1 |
| 85000-071_TECH_F300_IPS Pipe_LIB22TMP (1) |
| Page 1 |
| Page 2 |
| Aladin-750-No-Niche-Skimmer |
| AM-BA-01 |
| BL.GA500.01 |
| Flyer - BADU Pro UVS - |
| Flyer-Model-95- |
| HRVR |
| PIC GAUGE |
| Stenner 45m-85m spec sheet |
| THERMOMETER |
| Waterco Multiport valve cut sheet |
File details come from the government source that posted it. Updated .